Skip to product information
1 of 5

MRCOOL

MRCOOL VersaPro 5 Ton Horizontal Package Heat Pump, MPH601HO13C

SKU: MPH601HO13C

System highlights
AC Type
Packaged Units
Refrigerant Type
R454B
Brand
MRCOOL
Outdoor Unit
60000 BTU VO (5.0 TON)
Voltage
208-230V
Looking For
Packaged Heat Pump Units
Series
VersaPro
SEER2 Rating
13.4
Phase
Single Phase
Furnace Heating BTU
110,000 BTU (9.16 Ton)
Furnace Efficiency
81% AFUE

Price

$5,289.00
Shipping calculated at checkout.
Quantity
View full details
MRCOOL — VersaPro® R-454B Package Heat Pump

MRCOOL VersaPro® 5 Ton Horizontal Packaged Heat Pump (R-454B) — MPH601HO13C

Overview

5 Ton Horizontal Discharge 13.4 SEER2 11 EER2 HSPF2-4 6.7 R-454B Refrigerant 24V Thermostat AHRI Certified

The MRCOOL® VersaPro® MPH601HO13C is a high-capacity horizontal packaged heat pump built for dependable cooling and heating with steady airflow and quiet operation. It uses R-454B refrigerant and pairs a high-efficiency scroll compressor with an ECM blower motor for consistent comfort. The cabinet is power-painted galvanized steel, with aluminum tubing/fin coils for corrosion resistance and long service life.

Highlights

  • Efficiency: 13.4 SEER2 / 11 EER2 / HSPF2-4 6.7.
  • Capacity: 56,500 BTU cooling and 56,000 BTU heating.
  • Airflow: 1750 CFM listed.
  • Refrigerant: R-454B (lower GWP than older refrigerants).
  • Components: Scroll compressor, ECM condenser fan motor, ECM blower motor.
  • Aux heat ready: optional heat strips available (5 / 7.5 / 10 / 15 / 20 kW).
  • Controls: standard 24V thermostat.

What’s Included

  • Packaged heat pump unit: MPH601HO13C

Performance & Electrical

Capacity 5 Ton
Cooling Capacity 56,500 BTU
Heating Capacity 56,000 BTU
Efficiency 13.4 SEER2 • 11 EER2 • HSPF2-4: 6.7
Airflow 1750 CFM
Power 208/230V • 1 Phase • 60 Hz
Max Fuse / Breaker 60A
Minimum Circuit Ampacity 48.6A
Refrigerant R-454B • 95 oz
Sound Level 81 dBA
Min Ambient Cooling 32°F
Min Ambient Heating -0.4°F

Connections & Components

Control Type 24V Thermostat
Drain Connection 3/4"
Compressor Scroll (non-inverter)
Condenser Fan ECM • 1/4 HP
Blower Motor ECM • 3/4 HP • 3 Speeds
Metering Device Piston
Auxiliary Heat Not included • Optional: 5 / 7.5 / 10 / 15 / 20 kW

Dimensions & Weight

Net 42.06" W × 58.5" D × 33.06" H • 450 lb
Gross 42.24" W × 59.25" D × 34.07" H • 467 lb

Important

  • Aux heat: Optional heat strip kits are available (5 / 7.5 / 10 / 15 / 20 kW); not included.
  • Warranty: Base coverage listed as 5-year parts / 5-year compressor. Registered coverage listed as 10-year parts / 10-year compressor.
  • Electrical: Confirm breaker sizing, wire gauge, and disconnect requirements per local code and the install manual.
  • Prop 65: This product includes a Proposition 65 warning.

FAQs

What efficiency ratings does this unit have?

13.4 SEER2, 11 EER2, and HSPF2-4 6.7.


What size area is a 5 ton packaged heat pump typically used for?

It depends on insulation, windows, ceiling height, climate, and duct design. A 5-ton system is commonly used for larger homes/spaces, but the correct size should be based on a Manual J load calculation and duct evaluation.


Does it support auxiliary electric heat strips?

Yes. Auxiliary heat is available in 5 / 7.5 / 10 / 15 / 20 kW sizes (not included).


What are the electrical requirements?

Listed as 208/230V, 1-phase, with 60A max fuse/breaker and 48.6A MCA. Always verify requirements in the installation manual and local electrical code.


What is the refrigerant and charge amount?

Refrigerant is R-454B, with a factory charge listed at 95 oz.


What are the unit’s capacities and airflow?

Cooling: 56,500 BTU. Heating: 56,000 BTU. Airflow listed at 1750 CFM.


What are the listed minimum ambient temperatures?

Minimum ambient cooling is 32°F. Minimum ambient heating is -0.4°F.