Skip to product information
1 of 8

MRCOOL

MRCOOL Signature 4 Ton 48K BTU Cooling Only Central Ducted Split System

SKU: MCAESAS4T4821AA + MCAEAMPEF48E21AA

System highlights
AC Type
AC Air Handler Systems
Refrigerant Type
R454B
Brand
MRCOOL
Outdoor Unit
48000 BTU VO (4.0 TON)
Indoor Unit
48000 BTU (4.0 TON)
Voltage
208-230V
Looking For
Ducted
Series
Singnature Series
SEER2 Rating
13.8

Price

$3,699.51
Shipping calculated at checkout.
Quantity
View full details
MRCOOL — Signature Series Split System (Air Handler + Cooling-Only Condenser)

MRCOOL® Signature Series 48K (4 Ton) Split AC System — MCAEAMPEF48E21AA + MCAESAS4T4821AA

Overview

48K Class 4 Ton Up to 13.8 SEER2 11.2 EER2 R-454B Cooling Only Multi-Position Air Handler Upflow / Downflow / Horizontal ECM Blower AHRI Certified 10-Year Parts Warranty

TheMRCOOL® Signature Series 48Ksplit system combines amulti-position air handlerwith a cooling-only condenserfor high-capacity residential cooling. This pairing is designed for flexible installs (upflow, downflow, or horizontal) and usesR-454B refrigerantacross the system. Note the larger 7/8" suction lineon this 4-ton class setup.

Highlights

  • Multi-position install:Air handler supportsupflow, downflow, and horizontalconfigurations.
  • ECM airflow performance:Air handler uses a high-efficiencyECM blower(5 speeds) for strong, steady airflow.
  • High-capacity cooling:Condenser rated4 tonwith45,000 BTUlisted cooling capacity.
  • Modern refrigerant:System usesR-454B.
  • Long-line capable:Condenser lists up to150 ftmaximum line set length.
System Size
4 Ton (48K Class)
Efficiency
Up to 13.8 SEER2
Line Sizes
3/8" Liquid • 7/8" Suction
Max Line Set
150 ft

Sizing and performance depend on installation, duct design, and load. Manual J sizing is recommended.

What’s Included

  • Multi-Position Air Handler:MCAEAMPEF48E21AA
  • Cooling-Only Condenser:MCAESAS4T4821AA
  • Documentation (see Documents & Downloads)

Indoor Specs

Model:MCAEAMPEF48E21AA (Signature Series Multi-Position Air Handler)

Unit Type Air Handler
Configuration / Mount Multi-Position (Upflow / Downflow / Horizontal)
Tonnage 4 Ton
Airflow (CFM) 1549
Sound 57 dB(A)
Refrigerant R-454B
Metering Device Orifice
Drain Connection Size 3/4"
Line Sizes Liquid 3/8" • Suction 7/8"
Blower Motor Type ECM
Blower Motor 3/4 HP • 5 Speeds • 1010 RPM
Filter Replaceable • 20" × 24" × 1"
Electrical 208/230V • 1-Phase • 60 Hz
Min Circuit Ampacity (MCA) 7.2A
Max Fuse / Breaker 10A
Aux Heat Not included • Optional heat kit available (5 kW, 7.5 kW, 10 kW)
Certifications UL Listed • CSA Listed • ETL Listed • AHRI Certified
Color Grey
Dimensions (W×D×H) 22" × 24.5" × 53.125"
Net Weight 163 lb
GTIN / UPC GTIN 00840255595896 • UPC 840255595896
Proposition 65 Yes

Designed to work withSignature Series top discharge condensersand most third-party thermostats.

Outdoor Specs

Model:MCAESAS4T4821AA (Signature Series Split System AC Condenser — Cooling Only)

Unit Type Split System AC Condenser (Cooling Only)
Tonnage 4 Ton
Cooling Capacity 45,000 BTU
Efficiency 13.8 SEER2 • 11.2 EER2
Airflow (CFM) 4000
Sound 65 dB(A)
Inverter No
Min Ambient Cooling 59°F
Refrigerant R-454B • 116.4 oz
Max Line Set Length 150 ft
Line Sizes Liquid 3/8" • Suction 7/8"
Compressor Scroll
Condenser Fan Motor PSC • 1/3 HP
Electrical 208/230V • 1-Phase • 60 Hz
Min Circuit Ampacity (MCA) 30A
Max Fuse / Breaker 50A
Certifications UL Listed • CSA Listed • ETL Listed • AHRI Certified
Color Grey
Dimensions (W×D×H) 29.14" × 29.14" × 32.875"
Net Weight 204 lb
GTIN / UPC GTIN 00840255595759 • UPC 840255595759
Proposition 65 Yes

Designed to work withSignature Series Multi-PositionorStud Mountair handlers.

Documents & Downloads

Important

  • Cooling-only outdoor unit:This condenser is listed ascooling only. If you need heating via outdoor equipment, select a compatible heat pump condenser instead.
  • Line sizes:Listed as3/8" liquidand7/8" suction; confirm routing and any long-line requirements in the installation manual.
  • Line set length:Condenser lists up to150 ftmaximum line set length; verify long-line accessories/requirements in the install manual.
  • Electrical:Both components are208/230V, 1-phase, 60 Hz. Verify breaker/fuse sizing per install manual and local code.
  • Air handler orientation:Supportsupflow, downflow, and horizontalinstallation; configure condensate management for the selected position.
  • Optional heat kits:Supported sizes listed as5 kW,7.5 kW, and10 kW(sold separately).

FAQs

Is this a heat pump system?

No. The outdoor unit in this pairing is acooling-onlycondenser. Heating requires a different outdoor unit (heat pump) or an indoor heat source such as an optional electric heat kit.


What installation positions does the air handler support?

The air handler ismulti-positionand supportsupflow, downflow, and horizontalconfigurations.


What refrigerant and line sizes does it use?

Refrigerant is listed asR-454B. Line sizes are3/8" liquidand7/8" suction.


What is the maximum line set length?

The condenser lists a maximum line set length of150 ft.


What warranty coverage is included?

Warranty is listed as10-year limited parts, withlimited compressorcoverage referenced for the outdoor unit.