Skip to product information
1 of 8

MRCOOL

MRCOOL Signature 4 Ton 48K BTU Central Ducted Heat Pump Split System

SKU: MCAESHS4T4821AA + MCAEAMPEF48E21AA

System highlights
AC Type
Air Handler
Refrigerant Type
R454B
Brand
MRCOOL
Outdoor Unit
48000 BTU VO (4.0 TON)
Indoor Unit
48000 BTU (4.0 TON)
Voltage
208-230V
Looking For
Ducted
Series
Singnature Series
SEER2 Rating
14.3
Airflow Direction
Upflow, Downflow, Horizontal, Multi-Positional
Blower Motor
ECM

Price

$3,849.65
Shipping calculated at checkout.
Quantity
View full details
MRCOOL — Signature Series Split System (Multi-Position Air Handler + Heat Pump Condenser)

MRCOOL® Signature Series 48K (4 Ton) Heat Pump System — MCAEAMPEF48E21AA + MCAESHS4T4821AA

Overview

48K Class4 TonHeat Pump14.3 SEER211.2 EER27.5 HSPF2R-454BMulti-Position Air HandlerUpflow / Downflow / HorizontalECM BlowerAHRI Certified10-Year Parts Warranty

TheMRCOOL® Signature Series 48Kheat pump system pairs a4-ton multi-position air handlerwith asplit-system heat pump condenserfor year-round heating and cooling. The indoor unit supportsupflow, downflow, and horizontalinstalls, and both components useR-454B refrigerant.

Highlights

  • All-season comfort:Heat pump condenser listed forheating + cooling.
  • Efficiency ratings:Outdoor unit listed at14.3 SEER2,11.2 EER2, and7.5 HSPF2.
  • Flexible installation:Air handler supportsupflow, downflow, and horizontalconfigurations.
  • Service-friendly pairing:Outdoor unit lists150 ftmaximum line set length for flexible placement.
  • Cold-weather note:Outdoor unit lists5°Fminimum ambient heating operation.
System Size
4 Ton (48K Class)
Efficiency
14.3 SEER2 • 7.5 HSPF2
Line Sizes
3/8" Liquid • 7/8" Suction
Max Line Set
Up to 150 ft

Performance varies by climate and installation. Manual J sizing is recommended.

What’s Included

  • Multi-Position Air Handler:MCAEAMPEF48E21AA
  • Heat Pump Condenser:MCAESHS4T4821AA
  • Documentation (see Documents & Downloads)

Indoor Specs

Model:MCAEAMPEF48E21AA (Signature Series Multi-Position Air Handler)

Unit Type Air Handler
Configuration / Mount Multi-Position (Upflow / Downflow / Horizontal)
Tonnage 4 Ton
Airflow (CFM) 1549
Sound 57 dB(A)
Refrigerant R-454B
Metering Device Orifice
Drain Connection Size 3/4"
Line Sizes Liquid 3/8" • Suction 7/8"
Blower Motor Type ECM
Blower Motor 3/4 HP • 5 Speeds • 1010 RPM
Filter Replaceable • 20" × 24" × 1"
Electrical 208/230V • 1-Phase • 60 Hz
Min Circuit Ampacity (MCA) 7.2A
Max Fuse / Breaker 10A
Aux Heat Not included • Optional heat kit available (5 kW, 7.5 kW, 10 kW)
Certifications UL Listed • CSA Listed • ETL Listed • AHRI Certified
Color Grey
Dimensions (W×D×H) 22" × 24.5" × 53.125"
Net Weight 163 lb
GTIN / UPC GTIN 00840255595896 • UPC 840255595896
Proposition 65 Yes

Designed to work withSignature Series top discharge condensers.

Outdoor Specs

Model:MCAESHS4T4821AA (Signature Series Split System Heat Pump Condenser)

Unit Type Split System Heat Pump Condenser
Tonnage 4 Ton
Cooling / Heating Capacity 45,000 BTU / 45,000 BTU
Efficiency 14.3 SEER2 • 11.2 EER2 • 7.5 HSPF2
Airflow (CFM) 4000
Sound 65 dB(A)
Inverter No
Min Ambient (Cooling) 59°F
Min Ambient (Heating) 5°F
Refrigerant R-454B • 144.6 oz
Max Line Set Length 150 ft
Line Sizes Liquid 3/8" • Suction 3/4"
Compressor Scroll
Condenser Fan Motor PSC • 1/3 HP
Electrical 208/230V • 1-Phase • 60 Hz
Min Circuit Ampacity (MCA) 30A
Max Fuse / Breaker 50A
Certifications UL Listed • CSA Listed • ETL Listed • AHRI Certified
Color Grey
Dimensions (W×D×H) 29.14" × 29.14" × 32.875"
Net Weight 223 lb
GTIN / UPC GTIN 00840255595827 • UPC 840255595827
Proposition 65 Yes

Designed to work withSignature Series Multi-PositionorStud Mountair handlers.

Documents & Downloads

Important

  • Heat pump operation:This pairing includes aheat pump condenserforheating + cooling.
  • Minimum outdoor temps:Outdoor unit lists59°Fminimum ambient for cooling and5°Fminimum ambient for heating.
  • Line sizes:Air handler lists3/8" liquidand7/8" suction. Outdoor unit lists3/8" liquidand3/4" suction.Verify the correct suction line size for the matched pairing in the installation manualbefore ordering line sets.
  • Line set length:Outdoor unit lists up to150 ftmaximum line set length; verify long-line requirements in the install manual.
  • Electrical:Both components are208/230V, 1-phase, 60 Hz. Verify breaker/fuse sizing per install manual and local code.
  • Aux heat option:Air handler supports optional heat kits (listed as5 kW,7.5 kW, and10 kW) for added cold-weather comfort (sold separately).

FAQs

Does this system provide heating and cooling?

Yes. The outdoor unit is aheat pump condenser, so the system is listed forboth heating and cooling.


What installation positions does the air handler support?

The air handler ismulti-positionand supportsupflow, downflow, and horizontalconfigurations.


What refrigerant does it use?

Both components listR-454B.


What line sizes should I use?

Liquid line is listed as3/8". Suction line sizing shows a mismatch between the indoor (7/8") and outdoor (3/4") fields provided, soconfirm the correct suction line size for the matched pairingin the installation manual before selecting a line set.


How cold can it run in heating?

The outdoor unit lists a minimum ambient heating temperature of5°F.


What warranty coverage is included?

Warranty is listed as10-year limited parts, withlimited compressorcoverage referenced for the outdoor unit.