Skip to product information
1 of 6

MRCOOL

MRCOOL Signature 24K BTU 2 Ton 14.3 SEER2 Heat Pump Condenser and Stud Air Handler

SKU: MCAESHS4T2421AA + MCAEAWPEF24D21AA

System highlights
AC Type
Stud Mount Air Handler Heat Pump System
Refrigerant Type
R454B
Brand
MRCOOL
Outdoor Unit
24000 BTU VO (2.0 TON)
Indoor Unit
24000 BTU (2.0 TON)
Voltage
208-230V
Looking For
Ducted
Series
Singnature Series
SEER2 Rating
14.3
Airflow Direction
Upflow
Blower Motor
ECM

Price

$2,689.80
Shipping calculated at checkout.
Quantity
View full details
MRCOOL — Signature Series (Stud Mount Air Handler + Heat Pump Condenser)

MRCOOL® Signature Series 24K Heat Pump System (Stud Mount) — MCAEAWPEF24D21AA + MCAESHS4T2421AA

Overview

24K Class 2 Ton Heat Pump Stud Mount Air Handler Between-Stud Install ECM Blower 14.3 SEER2 11.7 EER2 7.5 HSPF2 R-454B AHRI Certified 10-Year Parts Warranty

This system combines the MRCOOL® Signature Series 24K stud mount air handler with the Signature Series 2-ton heat pump condenser for all-season heating and cooling. The stud mount air handler is designed to fit between standard wall studs and supports front or bottom return options for flexible installs.

Highlights

  • Space-saving stud mount: Designed for between-stud installation where a conventional air handler won’t fit.
  • Return air flexibility: Air handler supports front or bottom return configurations.
  • Efficient airflow: High-efficiency ECM blower motor for steady airflow and reduced energy use.
  • All-season comfort: Heat pump condenser provides heating + cooling, with 5°F minimum ambient heating operation.
  • Service-friendly: Outdoor unit lists sweat connection valves and an accessible gauge port for easier installation and maintenance.
System Size
2 Ton (24K Class)
Efficiency
14.3 SEER2 • 7.5 HSPF2
Line Sizes
3/8" Liquid • 3/4" Suction
Min Ambient
5°F Heat • 59°F Cool

Performance varies by climate and installation. Manual J sizing is recommended.

What’s Included

  • Stud Mount Air Handler: MCAEAWPEF24D21AA
  • Heat Pump Condenser: MCAESHS4T2421AA
  • Documentation (see Documents & Downloads)

Indoor Specs

Model: MCAEAWPEF24D21AA (Signature Series Stud Mount Air Handler)

Unit Type Air Handler
Configuration / Mount Stud Mount
Airflow Direction Upflow
Tonnage 2 Ton
Airflow (CFM) 797
Sound 54 dB(A)
Refrigerant R-454B
Metering Device Orifice
Drain Connection Size 3/4"
Line Sizes Liquid 3/8" • Suction 3/4"
Blower Motor Type ECM
Blower Motor 1/3 HP • 5 Speeds • 1010 RPM
Filter Replaceable • 15" × 19" × 1"
Electrical 208/230V • 1-Phase • 60 Hz
Min Circuit Ampacity (MCA) 2.5A
Max Fuse / Breaker 3A
Aux Heat Not included • Optional heat kit available (5 kW, 7.5 kW, 10 kW)
Certifications UL Listed • CSA Listed • ETL Listed • AHRI Certified
Color Grey
Dimensions (W×D×H) 20.5" × 15" × 36"
Net Weight 88 lb
GTIN / UPC GTIN 00840255595926 • UPC 840255595926
Proposition 65 Yes

Designed to work with Signature Series top discharge condensers.

Outdoor Specs

Model: MCAESHS4T2421AA (Signature Series Split System Heat Pump Condenser)

Unit Type Split System Heat Pump Condenser
Tonnage 2 Ton
Cooling / Heating Capacity 22,000 BTU / 22,000 BTU
Efficiency 14.3 SEER2 • 11.7 EER2 • 7.5 HSPF2
Airflow (CFM) 1950
Sound 60 dB(A)
Inverter No
Min Ambient (Cooling) 59°F
Min Ambient (Heating) 5°F
Refrigerant R-454B • 91.7 oz
Max Line Set Length 100 ft
Line Sizes Liquid 3/8" • Suction 3/4"
Compressor Scroll
Condenser Fan Motor PSC • 1/9 HP
Electrical 208/230V • 1-Phase • 60 Hz
Min Circuit Ampacity (MCA) 15.2A
Max Fuse / Breaker 20A
Certifications UL Listed • CSA Listed • ETL Listed • AHRI Certified
Color Grey
Dimensions (W×D×H) 23.6" × 23.6" × 25"
Net Weight 144 lb
GTIN / UPC GTIN 00840255595780 • UPC 840255595780
Proposition 65 Yes

Designed to work with Signature Series multi-position or stud mount air handlers.

Documents & Downloads

Important

  • Stud mount configuration: Designed to fit between studs; supports front and bottom return air (verify clearances in the install manual).
  • Line sizes: Both components list 3/8" liquid and 3/4" suction.
  • Line set length: Outdoor unit lists up to 100 ft maximum line set length; verify long-line requirements in the install manual.
  • Minimum outdoor temps: Outdoor unit lists 59°F minimum ambient for cooling and 5°F minimum ambient for heating.
  • Electrical: Both components are 208/230V, 1-phase, 60 Hz. Verify breaker/fuse sizing per install manual and local code.
  • Aux heat option: Air handler supports optional heat kits (listed as 5 kW, 7.5 kW, 10 kW) for added cold-weather comfort (sold separately).

FAQs

What is a stud mount air handler?

A stud mount air handler is designed to fit between standard wall studs, helping solve installs where a traditional cabinet won’t fit in a closet/utility space.


Does this system provide heating and cooling?

Yes. The outdoor unit is a heat pump condenser, so the system is listed for heating and cooling.


What refrigerant does it use?

Both components list R-454B.


How cold can it run in heating?

The outdoor unit lists a minimum ambient heating temperature of 5°F.


What warranty coverage is included?

Warranty is listed as 10-year limited parts, with limited lifetime compressor coverage referenced for the outdoor unit.