Cooper&Hunter Hyper Olivia Midnight 2-Zone Ductless Mini Split AC & Heat Pump 19000 BTU (9K+24K), Wall Mount Units, 230V
The Cooper & Hunter Olivia Midnight Series system pairs a 19000 BTU outdoor unit with CH-RVHP19M-230VO + CH-RB09MOLVWM-230VI + CH-RB24MOLVWM-230VI Olivia Midnight (black) wall-mounted indoor units. This high-efficiency DC inverter heat pump delivers zoned comfort in 2 zones and supports low-ambient heating & cooling down to -22 F.
Key features
Comfort & airflow
- 2-zone independent temperature control
- Auto-swing louvers for broad air distribution
- Multiple fan speeds (LOW / MED / HI / TURBO)
- Turbo mode for rapid cooling/heating
- Follow Me mode (remote-based temperature sensing)
- Timer On/Off scheduling + Sleep mode
- LED display (model-dependent)
Efficiency & protection
- High efficiency operation (up to 25 SEER2)
- Low-ambient performance down to -22 F
- 46°F Freeze Protection
- Self-clean function (single-zone models only, if equipped)
- Eco mode (single-zone models only, if equipped)
Build & materials
- TU1 copper tubes for durability and heat transfer
- Genius Core ultra-low compressor speed (12Hz) for quiet, stable operation
- Quiet operation (Outdoor as low as 61.5 dB(A); Indoor as low as 19.5 dB(A))
At-a-glance
2 zones
19000
25
-22 F
61.5 dB(A)
19.5 dB(A)
CH-RVHP19M-230VO
Smart Kit Included
Warranty requires licensed HVAC installation and registration within 60 days (if required).
Control options
- Smart Kit included with downloadable C&H app
- Remote control included (new user-friendly design)
- 12V wall thermostat compatible (purchased separately)
Outdoor technology
- High-Frequency Racer Technology: helps the compressor reach maximum speed within ~6 seconds on startup
- Electronic expansion valve: optimizes refrigerant flow management
- Intelligent dusting switch: reverses the fan to help clear dust/sand/debris from the coil
- Genius Core ultra-low compressor speed of 12Hz
Installation & electrical
- Indoor line sizes (varies by head): 3/8"/5/8"
- Refrigerant precharge: 75
- Additional refrigerant charge (1/4 liquid line): 0.16
- Additional refrigerant charge (3/8 liquid line): 0.16
- Minimum circuit ampacity: 17.5
- Max fuse / breaker: 20
Use the installation manual to confirm charge units and when additional charge is required (based on line length and piping configuration).
Product video
What’s included
Cooper & Hunter Olivia Midnight Series Ductless Mini Split System
Outdoor Unit: 19000 BTU (1 pc) — Model: CH-RVHP19M-230VO
Indoor Units:
- 9,000 BTU (x1) — Model: CH-RB09MOLVWM-230VI
- 24,000 BTU (x1) — Model: CH-RB24MOLVWM-230VI
- Installation Kits options (No Installation / 16 ft / 25 ft / 50 ft)
- (INSTALLATION KIT SIZE MUST BE SELECTED, TO INCLUDE)
- Wireless Remote Controls (2 remotes)
- Smart Kit Included
- Installation Manual
- User's Manual
- Manufacturer Warranty
Complete technical specifications — Indoor
Indoor Unit Specifications — CH-RB09MOLVWM-230VI
| Rated V-Ph-Hz | 208/230,1,60 |
|---|---|
| Rated Capacity Btu/h | 9000 |
| Minimum Circuit Ampacity (MCA) A | 3 |
| Max. Fuse A | 15 |
| Indoor Air Flow (Turbo/Hi/Mi/Lo/Si) CFM | 382.6/294.3/194.2/153.0/N/A |
| Indoor Noise Level (Turbo/Hi/Mi/Lo/Si) dB(A) | 45.5/42/36/21/19.5 |
| Dimension (WxDxH) inch | 31.57×7.87×11.61 |
| Packing (WxDxH) inch | 34.45×11.22×14.96 |
| Net/Gross Weight lbs | 18.96/24.25 |
| Cooling Temp °F | 60–90 |
| Heating Temp °F | 32–86 |
| Liquid/Gas Side inch | 1/4″/3/8″ |
| EER2 | 15.8 |
| SEER2 | 26.4.1 |
| Unit Net/Gross weight | 18.96/24.25 |
| Unit dimensions (W*H*D) | 31.57x7.87x11.61 |
| Operation Range - Heating | 32~86 |
| Operation Range - Cooling | 60~90 |
| Minimum circuit ampacity | 3 |
| Max.fuse | 15 |
| Indoor Noise Level H/M/L | 40/34/23.5 |
| Indoor Air Flow | 341.18/291.18/194.12/152.94 |
| Drainage water pipe diameter | 5/8" |
Indoor Unit Specifications — CH-RB24MOLVWM-230VI
| Refrigerant type | R454B |
|---|---|
| System type | Single/Multi-zone unit |
| BTU Rated | 24,000 |
| Power source | 208-230V, 1Ph, 60Hz |
| Dehumidification value (pnt/day) | 5.43 |
| Voltage range (V) | 187-253 |
| Packing dimensions (WxDxH) | 45.47x16.34x12.40 |
| Controller | RG10K-exclusive remote |
| Refrigerant piping Liquid/Gas side (inch) | 3/8"/5/8" |
| EER2 | 13.5 |
| SEER2 | 22.3 |
| Unit Net/Gross weight | 29.98/38.14 |
| Unit dimensions (W*H*D) | 42.64x9.61x13.23 |
| Operation Range - Heating | 32~86 |
| Operation Range - Cooling | 60~90 |
| Minimum circuit ampacity | 3 |
| Max.fuse | 15 |
| Indoor Noise Level H/M/L | 48/40/28 |
| Indoor Air Flow | 760.59/601.18/458.82/382.35 |
| Drainage water pipe diameter | 5/8" |
Submittals
- https://media.cooperandhunter.us/4952/CH-RES09-230VO-_-CH-RB09MOLVWM-230VI.pdf
- https://media.cooperandhunter.us/4962/CH-RB09MOLVWM-230VI.pdf
- https://media.cooperandhunter.us/4958/CH-RHP09-230VO_CH-RB09MOLVWM-230VI.pdf
- https://media.cooperandhunter.us/4956/CH-RES24-230VO-_-CH-RB24MOLVWM-230VI.pdf
- https://media.cooperandhunter.us/4965/CH-RB24MOLVWM-230VI.pdf
- https://media.cooperandhunter.us/4961/CH-RHP24-230VO_CH-RB24MOLVWM-230VI.pdf
Complete technical specifications — Outdoor
Outdoor Unit Specifications — CH-RVHP19M-230VO
| Rated V-Ph-Hz | 208/230, 1, 60 |
|---|---|
| Voltage Range (V) | 187-253 |
| Cooling Rated Capacity (range) Btu/h | 5,400~28,000 |
| Cooling Rated Current A | 5.6 |
| Cooling EER2 Btu/h/W | 15 |
| Cooling SEER2 | 25 |
| Heating at 47°F Rated Capacity (range) Btu/h | 5,700~27,000 |
| Heating at 47°F Rated Current A | 6.5 |
| Heating at 47°F COP W/W | 4 |
| Heating at 47°F HSPF4 | 10.4 |
| Heating at 47°F HSPF5 | 8.5 |
| Heating at 5°F Rated Capacity Btu/h | 19,000 |
| Minimum Circuit Ampacity (Outdoor unit) A | 17.5 |
| Max. Fuse (Outdoor unit) A | 20 |
| Outdoor Air Flow (Max) CFM | 2,130.7 |
| Outdoor Noise Level (Sound Pressure) dB(A) | 61.5 |
| Dimension (W×D×H) inch | 37.24x16.14x31.89 |
| Packing (W×D×H) inch | 42.91x19.68x34.84 |
| Net/Gross Weight lbs | 137.35/148.15 |
| Refrigerant Type/Charged oz | R454B/78.31 |
| Refrigerant Precharge ft | 75 |
| Additional Charge for Each oz/ft | 0.16 |
| Design Pressure PSIG | 550/340 |
| Refrigerant Piping Liquid Side inch | 3 x 1/4” |
| Refrigerant Piping Gas Side inch | 3 x 3/8” |
| Max. Pipe Length ft | 196.8 |
| Max. Length for One Indoor Unit ft | 98.4 |
| Max. Height Difference in Level ft | 49.2 |
| Max. Height Difference Between Indoor Units ft | 33 |
| Ambient Temperature Cooling °F | -22~122 |
| Ambient Temperature Heating °F | -22~75 |
| Certifications AHRI | ✓ |
| Certifications Energy Star for Cold Climate | ✓ |
| Certifications NEEP | ✓ |
| Certifications ETL | ✓ |
Manuals
Submittals
Documents
Warranty information
- 7-Year Compressor Warranty
- 5-Year Parts Warranty
- 1-Year Remote Control Warranty
Note: Warranty valid only when installed by a licensed HVAC technician and registered within 60 days of installation.
Summary
Expand
Transform your home's climate control with the Cooper & Hunter Olivia Midnight wall mounted mini split (R454B refrigerant). The midnight black indoor unit delivers modern style with advanced comfort features, including auto-swing louvers, Turbo mode, Follow Me temperature sensing, and Smart Kit app control. Designed for quiet, efficient performance (up to 25 SEER2), it supports low-ambient operation down to -22 F and in