Cooper&Hunter Hyper 3-Zone Ductless Mini Split AC & Heat Pump 36000 BTU (18K+18K+18K), Universal Floor/Ceiling Units, 230V
Discover the flexibility of the Cooper & Hunter Universal Floor / Ceiling system. A 36000 BTU outdoor condenser powers versatile indoor units that can be installed horizontally from a ceiling or vertically on a wall—ideal for spaces where a traditional wall mount isn’t the best fit. This inverter heat pump provides independent control in 3 zone(s) and supports low-ambient heating down to -22 F.
Universal Floor / Ceiling units are engineered for convenience and efficiency (ratings vary by size, up to 23 SEER2) and can include TU1 copper tubing, built-in Smart Kit app control, and comfort-optimizing sensors such as refrigerant and humidity detection (where equipped). A strong choice for small businesses, retail stores, and homes that need premium performance with installation flexibility.
Key features
Installation flexibility
- Install horizontally from the ceiling or vertically on a wall
- Great for open areas, storefronts, offices, and spaces with limited wall-mount options
- Convenient installation and maintenance access (layout dependent)
Comfort & performance
- 3-zone independent temperature control
- Efficient operation up to 23 SEER2 (model dependent)
- Quiet operation (Outdoor as low as 65 dB(A); Indoor as low as 29 dB(A))
- Reliable heating down to -22 F ambient
- Turbo mode for rapid conditioning
Built-in components
- TU1 copper tubing for durability and efficient heat transfer
- Built-in Smart Kit with downloadable C&H app (where equipped)
- Refrigerant sensor + humidity sensor (where equipped) for comfort optimization
- Excellent option for small businesses and retail stores needing consistent temperature regulation
Included sensors and control hardware can vary by specific indoor unit model (see the spec tables below).
At-a-glance
3
36000
23
-22 F
65 dB(A)
29 dB(A)
CH-RVHP36M-230VO
Ceiling / Wall
Warranty requires licensed HVAC installation and registration within 60 days (if required).
Control options
- Smart Kit built in with downloadable C&H app (where equipped)
- Remote control included
- Wall thermostat (purchased separately)
Product video
What’s included
Cooper & Hunter Universal Floor / Ceiling Mini Split System
Outdoor Unit: 36000 BTU (1 pc) — Model: CH-RVHP36M-230VO
Indoor Units (Universal Floor / Ceiling):
- 18,000 BTU (x3) — Model: CH-RSH18MFC
- Installation-Kit options (No Kit / 16 ft / 25 ft / 50 ft)
- (INSTALLATION KIT SIZE MUST BE SELECTED, to be included)
- Wireless Remote Controls (3 remotes)
- Built-in Smart-Kit & C&H App control
- Wall Thermostat (purchased separately)
- Installation & User Manuals
- Manufacturer Warranty
Complete technical specifications — Indoor (Universal Floor / Ceiling)
Indoor Unit Specifications — CH-RSH18MFC
| Rated V-Ph-Hz | 208/230,1,60 |
|---|---|
| Cooling Btu/h | 18000 |
| Heating Btu/h | 18000 |
| Minimum Circuit Ampacity (MCA) A | 1.9 |
| Max. Fuse A | 15 |
| Indoor Air Flow (Turbo/Hi/Mi/Lo/Si) CFM | 576.6/574.5/485.6/428.0/N/A |
| Indoor Noise Level (Turbo/Hi/Mi/Lo/Si) dB(A) | N/A/43.0/40.0/32.0/29.0 |
| Dimension (WxDxH) inch | 42.0×26.5×7.9 |
| Packing (WxDxH) inch | 45.0×29.7×12.5 |
| Net/Gross Weight lbs | 58.42/70.55 |
| Cooling Temp °F | 60–90 |
| Heating Temp °F | 32–86 |
| Liquid/Gas Side inch | 1/4″ / 1/2″ |
| EER2 | 12.5 |
| SEER2 | 20.4 |
| Unit Net/Gross weight | 58.42/70.55 |
| Unit dimensions (W*H*D) | 42.05 x 26.57 x 9.25 |
| Operation Range - Heating | 32~86 |
| Operation Range - Cooling | 60~90 |
| Minimum circuit ampacity | 1.9 |
| Max.fuse | 15 |
| Indoor Noise Level H/M/L | 42.5/39.5/30.5 |
| Indoor Air Flow | 576.8 / 547.4 / 485.6 / 420.8 |
| ESP Range | / |
| Drainage water pipe diameter | 1" |
Manuals
- https://media.cooperandhunter.us/4289/Installation-manual-LCFC.pdf
- https://media.cooperandhunter.us/4291/Floor-Ceiling-Leaflet-2025.pdf
- https://media.cooperandhunter.us/4290/Owners-manul-UFC_R454B.pdf
Submittals
- https://media.cooperandhunter.us/4625/CH-RES18-230VO_CH-RSH18MFC.pdf
- https://media.cooperandhunter.us/4630/CH-RHP18-230VO_CH-RSH18MFC.pdf
Documents
Complete technical specifications — Outdoor
Outdoor Unit Specifications — CH-RVHP36M-230VO
| Rated V-Ph-Hz | 208/230, 1, 60 |
|---|---|
| Voltage Range (V) | 187-253 |
| Cooling Rated Capacity (range) Btu/h | 9,000~43,000 |
| Cooling Rated Current A | 12 |
| Cooling EER2 Btu/h/W | 13 |
| Cooling SEER2 | 23 |
| Heating at 47°F Rated Capacity (range) Btu/h | 10,000~44,000 |
| Heating at 47°F Rated Current A | 11.5 |
| Heating at 47°F COP W/W | 4 |
| Heating at 47°F HSPF4 | 10.7 |
| Heating at 47°F HSPF5 | 8.5 |
| Heating at 5°F Rated Capacity Btu/h | 36,000 |
| Minimum Circuit Ampacity (Outdoor unit) A | 37 |
| Max. Fuse (Outdoor unit) A | 40 |
| Outdoor Air Flow (Max) CFM | 3,037.2 |
| Outdoor Noise Level (Sound Pressure) dB(A) | 65 |
| Dimension (W×D×H) inch | 38.58x16.34x38.39 |
| Packing (W×D×H) inch | 45.08x19.68x42.52 |
| Net/Gross Weight lbs | 211.86/244.71 |
| Refrigerant Type/Charged oz | R454B/134.04 |
| Refrigerant Precharge ft | 125 |
| Additional Charge for Each oz/ft | 0.16 |
| Design Pressure PSIG | 550/340 |
| Refrigerant Piping Liquid Side inch | 5 x 1/4” |
| Refrigerant Piping Gas Side inch | 3 x 3/8” + 2 x 1/2” |
| Max. Pipe Length ft | 262.4 |
| Max. Length for One Indoor Unit ft | 114.8 |
| Max. Height Difference in Level ft | 49.2 |
| Max. Height Difference Between Indoor Units ft | 33 |
| Ambient Temperature Cooling °F | -22~122 |
| Ambient Temperature Heating °F | -22~75 |
Manuals
Submittals
Warranty information
- 7-Year Compressor Warranty
- 5-Year Parts Warranty
- 1-Year Remote Control Warranty
Note: Warranty valid only when installed by a licensed HVAC technician and registered within 60 days of installation.
Summary
Expand
This Cooper & Hunter Universal Floor / Ceiling system pairs a 36000 BTU outdoor condenser with CH-RVHP36M-230VO + 3X CH-RSH18MFC floor/ceiling indoor unit(s) for flexible installation in commercial or residential spaces. Install horizontally from the ceiling or vertically on a wall for optimal coverage, while the inverter heat pump supports efficient operation up to 23 SEER2 and low-ambient heating down to -22 F.