Cooper&Hunter 9,000 BTU Olivia Midnight Single Zone Wall Mount Minisplit Heat Pump System R410A 230V
SKU: CH-B09MOLVWM-230VI + CH-ES09-230VO
Overview
The Cooper&Hunter 9,000 BTU Olivia Midnight system is a single-zone ductless mini split heat pump that combines modern black panel styling with inverter-driven comfort on 208–230V power. Auto-swing horizontal louvers help maintain even airflow throughout the room for consistent comfort.
Comfort and control features include Follow Me temperature sensing via the remote, Sleep and Timer modes, and 46° Freeze Protection. Control is handled by the included C&H remote, with optional smart control supported when used with an optional Smart Kit and the C&H Remote app. Genius Core Technology supports ultra-low compressor operation (12Hz) for added energy savings.
Highlights
- Style-forward indoor unit: sleek Olivia Midnight black front panel.
- Efficient performance: ES outdoor pairing rated 19.2 SEER2.
- Comfort control: Follow Me mode uses the remote sensor to help maintain comfort at your location.
- Quiet operation: indoor sound levels as low as 23.5 dB(A) (low).
- Cold weather operation: outdoor heating ambient range down to −13°F.
What’s Included
- Indoor unit: CH-B09MOLVWM-230VI (Olivia Midnight wall mount)
- Outdoor unit: CH-ES09-230VO (Single-Zone)
- Remote control (included)
- Manufacturer documentation (see Documents & Downloads)
- Installation kits are not included unless selected on the Variant Options (No installation, 16ft, 25ft, 50ft).
Indoor Specs
| Spec | Details |
|---|---|
| Model | CH-B09MOLVWM-230VI |
| System type | Single Zone (as configured) |
| BTU rated | 9,000 |
| Power source | 208–230V, 1Ph, 60Hz |
| Voltage range | 187–253 V |
| SEER2 | 26.4 |
| EER2 | 15.8 |
| Refrigerant piping (liq/gas) | 1/4" / 3/8" |
| Minimum circuit ampacity | 3 |
| Max fuse | 15 |
| Indoor noise level (H/M/L) | 40 / 35 / 23.5 dB(A) |
| Indoor air flow | 341.18 / 291.18 / 194.12 / 152.94 CFM |
| Dehumidification | 0.85 pnt/day |
| Unit dimensions (W×H×D) | 31.57 × 7.87 × 11.61 in |
| Net / Gross weight | 18.96 / 24.25 lb |
| Packing dimensions (W×D×H) | 34.45 × 11.22 × 14.96 in |
| Drain pipe diameter | 5/8" |
| Operating range (Cooling) | 60–90°F |
| Operating range (Heating) | 32–86°F |
| Controller | RG10K-exclusive remote |
Outdoor Specs
| Spec | Details |
|---|---|
| Model | CH-ES09-230VO |
| System type | Single Zone |
| Refrigerant type | R410A |
| BTU rated | 9,000 |
| Power source | 208–230V, 1Ph, 60Hz |
| Voltage range | 187–253 V |
| Refrigerant piping (liq/gas) | 1/4" / 3/8" |
| Max pipe length | 82.02 ft |
| Max height difference (IDU↔ODU) | 32.81 ft |
| Cooling capacity (Min/Max) | 9,000 (2,220–11,600) BTU/h |
| Heating capacity (Min/Max) | 10,000 (2,240–13,350) BTU/h |
| SEER2 | 19.2 |
| EER2 | 12.5 |
| HSPF2-5 | 8 |
| HSPF2-4 | 10.2 |
| COP | 3.62 |
| Dehumidification | 2.11 pnt/day |
| Outdoor noise level | 55 dB(A) |
| Outdoor air flow | 1,294.12 CFM |
| Minimum circuit ampacity | 13 |
| Max fuse | 15 |
| Ambient temp (Heating) | −13–75°F |
| Ambient temp (Cooling) | −13–122°F |
| Unit dimensions (W×H×D) | 30.12 × 11.93 × 21.85 in |
| Net / Gross weight | 63.71 / 69.00 lb |
| Packing dimensions (W×D×H) | 34.92 × 13.27 × 24.02 in |
| Refrigerant precharge | 25 |
| Additional charge (1/4" liquid) | 0.16 |
Documents & Downloads
- Submittal (PDF) — CH-ES09-230VO + CH-B09MOLVWM-230VI
- Indoor Submittal (PDF) — CH-B09MOLVWM-230VI
- Wall Mounted Installation Manual (PDF)
- Olivia Midnight Installation Manual (PDF)
- Olivia Midnight Owner’s Manual (PDF)
- Product Leaflet (PDF) — Olivia Midnight
- Accessories Leaflet (PDF) — 2023
- Remote Manual Content (PDF)
- Combination Reference (PDF) — Regular
- Combination Reference (PDF) — HYPER
- AHRI Directory Listing — AHRI #207742317
- Manufacturer Page — CH-B09MOLVWM-230VI
- Manufacturer Page — CH-ES09-230VO
Videos
Featured video
Mini-split installation videos
How To & Instructional Videos
Products overview
- HVAC Installation Kit: 99.9% Copper Line Sets (Cooper&Hunter)
- Mini Split Indoor Unit Types Explained
- Cooper&Hunter Olivia Series
Mini-Splits
- Can You Use a Mini Split in EXTREME COLD? Heat Pump vs. Propane Cost Comparison with Thermal Camera
- Where To Mount a Mini Split Indoor Wall Hung Unit
- How To Wall Mount a Mini Split Outdoor Condenser Unit
- Are Mini Split Air Conditioners Worth It? - Top 5 Pros & Cons
- Does a Wall Mounted MINISPLIT Need a CONDENSATE TRAP? Ductless vs Ducted Air Handlers!
- MINI SPLIT Parts Explained! Understand What They Do!
- Mini Split Failure from Electrical Surges, High and Low Voltage! HOW TO SOLVE IT!
- Full Installation of an Inverter Minisplit Heat Pump with Indoor Ceiling Cassette
- Checking the Refrigerant Charge on a Running R-410A Inverter MINI SPLIT Unit
- Mini Split Indoor Unit Types Explained! 5 Types- Applications, Connection Points, Mounting!
Important
Professional installation is recommended. Confirm electrical requirements, line sizes, maximum line length, and ambient operating limits before installation. Installation kits are not included unless selected on the Variant Options (No installation, 16ft, 25ft, 50ft).
FAQs
Is this a single-zone system?
What’s different about Olivia Midnight?
What line sizes does this system use?
What is the max line length and height difference?
How cold can this system operate in heating?
Are installation kits included?