High Static Slim Duct + Hyper Outdoor • R454B • 208–230V
Cooper&Hunter 60,000 BTU Hyper Single Zone Slim Duct Ducted Minisplit Heat Pump System R454B 230V
Overview
60K high-static slim duct system for single-zone and light commercial installations where concealed ducting and strong external static pressure are required. Built-in smart kit connectivity support, a refrigerant sensor, and multiple control options support flexible operation. Hyper outdoor performance supports heating in extreme cold climates.
Highlights
System Search
Voltage
208–230V (1Ph, 60Hz)
Voltage Range
187–253V
Max Line / Lift
246 ft / 98.4 ft
Outdoor MCA / Max Fuse
44A / 45A
Drain Size
1"
- High external static pressure support (ESP 0–0.8)
- Controls: remote control + wall thermostat + wired controller support
- Built-in smart kit connectivity support with app control
- TU1 copper tubing design
- Hyper Heating operation down to -22°F heating ambient
- Indoor install orientation: horizontal or vertical
What’s Included
- Indoor unit: CH-RS60LCDT-HS
- Outdoor unit: CH-RHP60LCU-230VO
- Remote control and wall thermostat
- Wired controller support
- Smart kit connectivity support
Indoor Specs (CH-RS60LCDT-HS)
| Spec | Value |
|---|---|
| Refrigerant Type | R454B |
| System Type | Single Zone |
| BTU Rated | 60,000 |
| Power Source | 208–230V, 1Ph, 60Hz |
| Voltage Range | 187–253V |
| Dehumidification | 7.67 pints/day |
| Filter Dimensions (W×D) | 24.80 × 12.60 in |
| Controller | Wire controller + remote controller available |
| Refrigerant Piping (Liquid/Gas) | 3/8" / 3/4" |
| EER2 | 10.2 |
| SEER2 | 15.8 |
| Minimum Circuit Ampacity | 5A |
| Max Fuse | 15A |
| Indoor Noise Level (H/M/L) | 52 / 48 / 42 |
| Indoor Air Flow | 2,001.2 / 1,706.9 / 1,412.6 / 1,118.3 |
| ESP Range | 0–0.8 |
| Drainage Water Pipe Diameter | 1" |
| Operation Range – Heating | 32–86°F |
| Operation Range – Cooling | 60–90°F |
| Unit Dimensions (W×H×D) | 55.12 × 31.50 × 14.96 in |
| Packing Dimensions (W×D×H) | 62.99 × 36.02 × 17.52 in |
| Unit Net / Gross Weight | 161.38 / 178.13 lb |
Outdoor Specs (CH-RHP60LCU-230VO)
| Spec | Value |
|---|---|
| Refrigerant Type | R454B |
| System Type | Single-zone unit |
| BTU Rated | 60,000 |
| Power Source | 208–230V, 1Ph, 60Hz |
| Voltage Range | 187–253V |
| Dehumidification | 7.67 pints/day |
| Max Pipe Length | 246 ft |
| Max Height Difference (Indoor↔Outdoor) | 98.4 ft |
| Refrigerant Piping (Liquid/Gas) | 3/8" / 3/4" |
| HSPF2-5 / HSPF2-4 | 8.7 / 10.4 |
| EER2 | 10.2 |
| SEER2 | 15.8 |
| Cooling Capacity (Min/Max) | 55,000 (14,200–60,000) BTU/h |
| Heating Capacity (Min/Max) | 60,000 (11,200–66,000) BTU/h |
| COP | 3.74 |
| Ambient Temperature – Heating | -22 to 75°F |
| Ambient Temperature – Cooling | -22 to 122°F |
| Refrigerant Precharge | 25 |
| Outdoor Noise Level | 63 |
| Outdoor Air Flow | 4,237.9 |
| Minimum Circuit Ampacity | 44A |
| Max Fuse | 45A |
| Additional Refrigerant Charge (3/8 liquid line) | 0.32 |
| Unit Dimensions (W×H×D) | 37.48 × 16.34 × 52.48 in |
| Packing Dimensions (W×D×H) | 43.11 × 19.49 × 58.27 in |
| Unit Net / Gross Weight | 230.38 / 261.69 lb |
| AHRI | 205287344 |
Documents & Downloads
- Submittal (This Pairing): CH-RHP60LCU-230VO + CH-RS60LCDT-HS
- Additional Submittals
- CH-R60LCU-230VO + CH-RS60LCDT-HS
- CH-RHP60LCU-230VO + CH-RS60LCAHU
- CH-RHP60LCU-230VO + CH-RSH60LCFC
- Indoor Manuals
- 120N Wire Controller — Owner’s Manual
- Installation Manual — High Static Duct
- Owner’s Manual — High Static Duct
- SlimDuct Leaflet — R454B
- Outdoor Manual
- SlimDuct Leaflet — R454B
Important
- Line set: 3/8" liquid and 3/4" suction (gas).
- Max piping: 246 ft total length and 98.4 ft vertical separation.
- Outdoor electrical: MCA 44A, max fuse 45A.
- Indoor electrical: minimum circuit ampacity 5A, max fuse 15A.
- AHRI number: 205287344.
- Support: hvacsupplies.com/pages/contact • (800) 543-8933
FAQs
What line set size does this system use?
3/8" liquid line and 3/4" suction (gas) line.
What is the external static pressure range?
ESP range: 0–0.8.
What are the indoor airflow values?
2,001.2 / 1,706.9 / 1,412.6 / 1,118.3.
What are the indoor noise levels?
52 / 48 / 42 (H/M/L).
What are the outdoor capacity ranges?
Cooling: 55,000 (14,200–60,000) BTU/h. Heating: 60,000 (11,200–66,000) BTU/h.
What is the maximum piping length and vertical separation?
246 ft maximum piping length and 98.4 ft maximum height difference.
How cold can it operate in heating?
Heating ambient range: -22°F to 75°F.
What is the cooling ambient range?
Cooling ambient range: -22°F to 122°F.
What electrical does it use?
208–230V, 1Ph, 60Hz. Voltage range: 187–253V. Outdoor MCA 44A (max fuse 45A). Indoor MCA 5A (max fuse 15A).
What controls are supported?
Remote control and wall thermostat, plus wired controller support.
Can the indoor unit be installed horizontally or vertically?
Yes. Horizontal or vertical installation is supported.
What is the indoor drain connection size?
1" drainage water pipe diameter.
What is the AHRI number?
205287344.