Skip to product information
1 of 13

Cooper&Hunter

Cooper&Hunter 6,000 BTU Hyper Single Zone One-Way Cassette Minisplit Heat Pump System R454B 230V

SKU: CH-RSH06-12MCT1W + CH-RHP06F9-230VO

System highlights
AC Type
One-way Cassette
Refrigerant Type
R454B
Brand
Cooper&Hunter
Outdoor Unit
6000 BTU VO (0.5 TON)
Indoor Unit
6000 BTU (0.5 TON)
Voltage
208-230V
Looking For
One-way Cassette
Cooling Area (sq.ft.)
150-250
Series
Hyper
SEER2 Rating
22.0
Line Set Length

NOTE: THE DEFAULT SELECTION DOES NOT INCLUDE AN INSTALLATION KIT. UPGRADE YOUR SELECTION TO ADD TO YOUR ORDER.

Price

$2,415.00
Shipping calculated at checkout.
Quantity
View full details

Single Zone • One-Way Ceiling Cassette • 6K–12K Configurable • R454B • 208–230V

Cooper&Hunter 6,000 BTU Hyper Single Zone One-Way Cassette Minisplit Heat Pump System R454B 230V

Overview

Compact, between-joist one-way ceiling cassette built for flexible installs in smaller spaces. The CH-RSH06-12MCT1W supports capacity selection (6K / 9K / 12K) via ENC1 dip switch and includes a built-in condensate pump. Pairing with the Hyper outdoor unit adds strong low-ambient performance for heating and cooling.

Highlights

R454B Refrigerant Between-Joist Fit 6K / 9K / 12K Selectable Built-In Pump Humidity Sensor Refrigerant Sensor Hyper Heating Outdoor
  • Designed to fit cleanly between structural ceiling beams for flexible placement.
  • Capacity can be set to 6K, 9K, or 12K via ENC1 dip switch for right-sized comfort.
  • Built-in condensate pump helps simplify drainage routing.
  • Humidity and refrigerant sensors support stable indoor conditions and system monitoring.
  • Hyper outdoor unit supports operation down to -22°F ambient in heating.

Indoor Model

CH-RSH06-12MCT1W

Outdoor Model

CH-RHP06F9-230VO

Line Set Size

1/4" Liquid • 3/8" Gas

Selectable Capacity

6K / 9K / 12K (ENC1)

Max Line Length

82 ft

Low-Ambient Heating

Down to -22°F

What’s Included

  • Indoor one-way ceiling cassette: CH-RSH06-12MCT1W
  • Outdoor condenser: CH-RHP06F9-230VO (Hyper)
  • Remote control (indoor control package)
  • Built-in condensate pump (indoor)
  • Smart kit capability for app control (setup required)

Indoor Specs (CH-RSH06-12MCT1W)

Spec Value
Refrigerant Type R454B
System Type Single Zone
BTU Rated 12,000 (capacity selectable: 6K / 9K / 12K)
Power 208–230V • 1Ph • 60Hz (Voltage Range: 187–253V)
SEER2 / EER2 23 / 13
Dehumidification 3.57 pints/day
Indoor Airflow (CFM) 353.2 / 312 / 282.5 / 247.2
Noise (dB(A)) 41 / 37 / 33 (H/M/L)
Unit Dimensions (W×D×H) 50.31 × 13.19 × 8.98 in
Net / Gross Weight 45.19 / 82.45 lb
Refrigerant Piping 1/4" Liquid • 3/8" Gas
Drain Pipe Diameter 3/4"
Operating Range Cooling: 60–90°F • Heating: 32–86°F
Minimum Circuit Ampacity 3 A
Max Fuse 15 A
Packing Dimensions (WxDxH) 57.60 × 22.48 × 22.64 in

Outdoor Specs (CH-RHP06F9-230VO)

Spec Value
Refrigerant Type R454B
BTU Rated 6,000
Cooling Capacity (Min–Max) 6,000 (2,300–12,600) BTU/h
Heating Capacity (Min–Max) 7,000 (3,000–11,000) BTU/h
HSPF2 (Region IV / V) 14.8 / 11.5
COP 4.2
AHRI 215864151
Power 208–230V • 1Ph • 60Hz (Voltage Range: 187–253V)
Max Pipe Length 82 ft
Max Height Difference 49.2 ft
Minimum Circuit Ampacity 12 A
Max Fuse 15 A
Outdoor Airflow 1,235.3 CFM
Outdoor Noise 53 dB(A)
Unit Dimensions (W×D×H) 30.12 × 11.93 × 21.85 in
Net / Gross Weight 62.17 / 67.68 lb
Ambient Temperature Cooling: -22–122°F • Heating: -22–75°F
Additional Charge 0.16 oz/ft (1/4" liquid line)

Important

  • Professional installation is recommended.
  • Confirm ENC1 dip switch capacity setting (6K / 9K / 12K) during commissioning.
  • Match line set sizes to the equipment: 1/4" liquid and 3/8" suction.
  • Verify the dedicated circuit is sized per equipment MCA and local code.
  • Need help choosing equipment? hvacsupplies.com/pages/contact(800) 543-8933

FAQs

How do I change the capacity from 6K to 9K or 12K?

Use the ENC1 dip switch on the CH-RSH06-12MCT1W to set the desired capacity (6K / 9K / 12K).

Does the indoor cassette include a condensate pump?

Yes. The CH-RSH06-12MCT1W includes a built-in condensate pump.

What line set sizes are required?

1/4" liquid line and 3/8" suction (gas) line.

How cold can the Hyper outdoor unit operate in heating?

CH-RHP06F9-230VO supports heating operation down to -22°F ambient.

Can I control the system with an app?

Smart kit capability supports app control through the C&H platform after setup.