Single Zone • 36,000 BTU • 4-Way Ceiling Cassette • R454B • 208–230V
Cooper&Hunter 36,000 BTU Hyper Single Zone Four-Way Ceiling Cassette w/ Humidity Sensor Minisplit Heat Pump System R454B 230V
Overview
A 36K 4-way ceiling cassette pairing designed for even distribution across large areas using a 360° airflow panel. Includes a built-in condensate pump and comfort modes like turbo and sleep. Pairing with the Hyper outdoor unit supports strong low-ambient heating for demanding climates.
Highlights
- 360° panel and omni-directional airflow helps cover large rooms evenly.
- Activated carbon filtration support for fresher indoor air.
- Anti-cold-air heating behavior reduces drafts during heat mode.
- Built-in pump with float switch (20.9" lift) for quiet condensate removal.
- Multiple fan speeds plus turbo and sleep modes for comfort control.
- Hyper outdoor supports heating operation down to -22°F ambient.
Indoor Model
Outdoor Model
Line Set Size
3/8" Liquid • 3/4" Gas
Power
208–230V • 1Ph • 60Hz
Max Line Length
246 ft
Low-Ambient Heating
Down to -22°F
What’s Included
- Indoor 4-way ceiling cassette: CH-RH36LCCT
- Outdoor condenser: CH-RHP36LCU-230VO (Hyper)
- Remote control (indoor control package)
- Ceiling Cassette Panel
- Built-in condensate pump with float switch (indoor)
- Smart Kit capability for app control (setup required)
Indoor Specs (CH-RH36LCCT)
| Spec | Value |
|---|---|
| Refrigerant Type | R454B |
| BTU Rated | 36,000 |
| Power | 208–230V • 1Ph • 60Hz (Voltage Range: 187–253V) |
| Refrigerant Piping | 3/8" Liquid • 3/4" Gas |
| Drain Pipe Diameter | 1" |
| Operating Range | Cooling: 60–90°F • Heating: 32–86°F |
| Minimum Circuit Ampacity | 3 A |
| Max Fuse | 15 A |
Tip: If you want the full CH-RH36LCCT spec table populated (dimensions, airflow, sound, weights, efficiency), paste the JSON/spec block for CH-RH36LCCT and I’ll drop it in.
Outdoor Specs (CH-RHP36LCU-230VO)
| Spec | Value |
|---|---|
| Refrigerant Type | R454B |
| System Type | Single-zone unit |
| BTU Rated | 36,000 |
| Cooling Capacity (Min–Max) | 36,000 (9,800–37,000) BTU/h |
| Heating Capacity (Min–Max) | 42,000 (11,000–45,500) BTU/h |
| SEER2 / EER2 | 17.7 / 12 |
| HSPF2 (Region IV / V) | 11.1 / 9.2 |
| COP | 3.8 |
| Power | 208–230V • 1Ph • 60Hz (Voltage Range: 187–253V) |
| Max Pipe Length | 246 ft |
| Max Height Difference | 98.4 ft |
| Minimum Circuit Ampacity | 38 A |
| Max Fuse | 40 A |
| Outdoor Airflow | 3,001.9 CFM |
| Outdoor Noise | 65 dB(A) |
| Unit Dimensions (W×D×H) | 38.58 × 16.34 × 38.39 in |
| Net / Gross Weight | 206.57 / 237.44 lb |
| Ambient Temperature | Cooling: -22–122°F • Heating: -22–75°F |
| Additional Charge | 0.32 oz/ft (3/8" liquid line) |
Documents & Downloads
- Submittal Sheet: CH-RHP36LCU-230VO + CH-RH36LCCT
- Submittal Sheet: CH-RHP36LCU-230VO + CH-RS36LCAHU
- Submittal Sheet: CH-RHP36LCU-230VO + CH-RS36LCDT-HS
- Submittal Sheet: CH-RHP36LCU-230VO + CH-RSH36LCFC
- SlimDuct Leaflet (R454B)
- Ceiling Cassette Installation Manual (R454B)
- Ceiling Cassette Owner’s Manual (R454B)
- 120N Wire Controller — Uses & Installation Manual
- MultiZone Combination Guide — Hyper
- MultiZone Combination Guide — Regular
Important
- Professional installation is recommended.
- Match line set sizes to the equipment: 3/8" liquid and 3/4" suction.
- Verify the dedicated circuit is sized per equipment MCA and local code.
- Need help choosing equipment? hvacsupplies.com/pages/contact • (800) 543-8933
FAQs
Does the cassette include a condensate pump?
Yes. Ceiling cassette models in this series include a built-in pump with float switch (20.9" lift).
What line set sizes are required?
3/8" liquid line and 3/4" suction (gas) line.
How cold can the Hyper outdoor unit heat?
CH-RHP36LCU-230VO supports heating operation down to -22°F ambient.
Can I control the system with an app?
Smart Kit capability supports app control through the C&H platform after setup.