System highlights
AC Type
Ceiling Cassette
Refrigerant Type
R454B
Brand
Cooper&Hunter
Outdoor Unit
24000 BTU VO (2.0 TON)
Indoor Unit
24000 BTU (2.0 TON)
Voltage
208-230V
Looking For
Ceiling Cassette
Cooling Area (sq.ft.)
1000-1500
Series
Pro
SEER2 Rating
22.0
Line Set Length
Regular price $2,344.00 USD
Regular price Sale price $2,344.00 USD
Sale Sold out
Shipping calculated at checkout.
Quantity
View full details

Single Zone • 4-Way Ceiling Cassette • R454B • 208–230V

Cooper&Hunter 24,000 BTU Pro Single Zone Four-Way Ceiling Cassette w/ Refrigerant & Humidity Sensor Minisplit Heat Pump System R454B 230V

Overview

A 24K four-way ceiling cassette pairing designed for wide, even airflow with added system protection. The CH-RSH24MCT cassette includes refrigerant leakage detection plus humidity sensing and self-diagnosis features, and includes a built-in condensate pump. Pair it with the CH-RES24-230VO regular outdoor unit for efficient, dependable comfort.

Highlights

R454B Refrigerant 360° Airflow Panel Leak Detection (RSH) Humidity Sensor GoldFin Coil Coating Built-In Condensate Pump Inverter Outdoor
  • Omni-directional airflow and 360° panel helps distribute air evenly throughout the room.
  • Activated carbon filtration support for fresher indoor air.
  • Refrigerant leakage detection helps protect the system in abnormal conditions.
  • Anti-cold-air heating behavior reduces drafts during heat mode.
  • Built-in pump with float switch (20.9" lift) for quiet condensate removal.
  • Regular outdoor unit supports heating operation down to -13°F ambient.

Indoor Model

CH-RSH24MCT

Outdoor Model

CH-RES24-230VO

Line Set Size

3/8" Liquid • 5/8" Gas

Outdoor SEER2

22

Max Line Length

164 ft

Low-Ambient Heating

Down to -13°F

What’s Included

  • Indoor 4-way ceiling cassette: CH-RSH24MCT
  • Outdoor condenser: CH-RES24-230VO (Regular)
  • Remote control (indoor control package)
  • Ceiling Cassette Panel
  • Built-in condensate pump with float switch (indoor)
  • Smart Kit capability for app control (setup required)

Indoor Specs (CH-RSH24MCT)

Spec Value
Refrigerant Type R454B
System Type Single Zone
BTU Rated 24,000
Power 208–230V • 1Ph • 60Hz (Voltage Range: 187–253V)
SEER2 / EER2 20.7 / 12
Dehumidification 4.99 pints/day
Indoor Airflow (CFM) 765.2 / 706.3 / 635.7 / 547.4
Noise (dB(A)) 45 / 42.5 / 33.5 (H/M/L)
Unit Dimensions (W×D×H) 32.68 × 32.68 × 8.07 in
Net / Gross Weight 47.18 / 59.08 lb
Refrigerant Piping 3/8" Liquid • 5/8" Gas
Drain Pipe Diameter 1"
Operating Range Cooling: 60–90°F • Heating: 32–86°F
Minimum Circuit Ampacity 3 A
Max Fuse 15 A

Outdoor Specs (CH-RES24-230VO)

Spec Value
Refrigerant Type R454B
System Type Single-zone unit
BTU Rated 24,000
Cooling Capacity (Min–Max) 24,000 (8,500–28,300) BTU/h
Heating Capacity (Min–Max) 25,000 (11,800–35,100) BTU/h
SEER2 / EER2 19 / 12.5
HSPF2 (Region IV / V) 11 / 8.5
COP 3.64
Power 208–230V • 1Ph • 60Hz (Voltage Range: 187–253V)
Max Pipe Length 164 ft
Max Height Difference 82 ft
Minimum Circuit Ampacity 24 A
Max Fuse 25 A
Outdoor Airflow 2,236.7 CFM
Outdoor Noise 60 dB(A)
Unit Dimensions (W×D×H) 37.24 × 16.14 × 31.89 in
Net / Gross Weight 122.13 / 132.28 lb
Ambient Temperature Cooling: -13–122°F • Heating: -13–75°F
Additional Charge 0.32 oz/ft (3/8" liquid line)

Important

  • Professional installation is recommended.
  • Match line set sizes to the equipment: 3/8" liquid and 5/8" suction.
  • Verify the dedicated circuit is sized per equipment MCA and local code.
  • For help choosing equipment, contact us: hvacsupplies.com/pages/contact(800) 543-8933

FAQs

What is the difference between RH and RSH cassettes?

RSH models add refrigerant leakage detection in addition to standard monitoring features.

What line set sizes are required for this 24K cassette?

3/8" liquid line and 5/8" suction (gas) line.

How cold can the regular outdoor unit operate in heating?

CH-RES24-230VO supports heating operation down to -13°F ambient.

Does the indoor cassette include a condensate pump?

Yes. CH-RSH24MCT includes a built-in pump with float switch (20.9" lift).