Medium Static Slim Duct + Regular Outdoor • R454B • 208–230V
Cooper&Hunter 18,000 BTU Single Zone Slim Duct Ducted Minisplit Heat Pump System R454B 230V
Overview
Concealed medium-static slim duct system paired with a Regular outdoor condenser for efficient heating and cooling. Designed for clean, unobtrusive installation with ducted air distribution.
Highlights
System Search
Voltage
208–230V (1Ph, 60Hz)
Voltage Range
187–253V
Max Line / Lift
98.4 ft / 65.6 ft
Outdoor MCA / Max Fuse
18A / 20A
Indoor Drain Size
1"
- Smart kit connectivity support with app control
- Control options: remote control + wall thermostat + wired controller support
- TU1 copper tubing design
- Refrigerant sensor for system monitoring
What’s Included
- Indoor unit: CH-RS18MDT-MS
- Outdoor unit: CH-RES18-230VO
- Remote control and wall thermostat
- Wired controller support (wire controller + remote controller available)
- Smart kit connectivity support
Indoor Specs (CH-RS18MDT-MS)
| Spec | Value |
|---|---|
| Refrigerant Type | R454B |
| System Type | Single Zone |
| BTU Rated | 18,000 |
| Power Source | 208–230V, 1Ph, 60Hz |
| Voltage Range | 187–253V |
| Dehumidification | 3.53 pints/day |
| Filter Dimensions (W×D) | 30.2 × 7.47 in |
| Controller | Wire controller + remote controller available |
| Refrigerant Piping (Liquid/Gas) | 1/4" / 1/2" |
| EER2 | 12 |
| SEER2 | 18 |
| Minimum Circuit Ampacity | 3A |
| Max Fuse | 15A |
| Indoor Noise Level (H/M/L) | 40 / 39 / 38 |
| Indoor Air Flow | 600.4 / 559.2 / 500.3 / 441.4 |
| ESP Range | 0–0.4 |
| Drainage Water Pipe Diameter | 1" |
| Operation Range – Heating | 32–86°F |
| Operation Range – Cooling | 60–90°F |
| Unit Dimensions (W×H×D) | 34.65 × 26.54 × 8.27 in |
| Packing Dimensions (W×D×H) | 42.13 × 28.54 × 11.02 in |
| Unit Net / Gross Weight | 54.45 / 66.14 lb |
Outdoor Specs (CH-RES18-230VO)
| Spec | Value |
|---|---|
| Refrigerant Type | R454B |
| System Type | Single-zone unit |
| BTU Rated | 18,000 |
| Power Source | 208–230V, 1Ph, 60Hz |
| Voltage Range | 187–253V |
| Dehumidification | 3.09 pints/day |
| Max Pipe Length | 98.4 ft |
| Max Height Difference (Indoor↔Outdoor) | 65.6 ft |
| Refrigerant Piping (Liquid/Gas) | 1/4" / 1/2" |
| HSPF2-5 / HSPF2-4 | 8.2 / 10.5 |
| EER2 | 12.5 |
| SEER2 | 20 |
| Cooling Capacity (Min/Max) | 17,000 (7,000–19,000) BTU/h |
| Heating Capacity (Min/Max) | 20,000 (5,500–22,000) BTU/h |
| COP | 3.47 |
| Ambient Temperature – Heating | -13 to 75°F |
| Ambient Temperature – Cooling | -13 to 122°F |
| Refrigerant Precharge | 25 |
| Outdoor Noise Level | 59 |
| Outdoor Air Flow | 1,765.8 |
| Minimum Circuit Ampacity | 18A |
| Max Fuse | 20A |
| Additional Refrigerant Charge (1/4 liquid line) | 0.16 |
| Unit Dimensions (W×H×D) | 35.04 × 13.46 × 26.50 in |
| Packing Dimensions (W×D×H) | 39.17 × 15.67 × 29.13 in |
| Unit Net / Gross Weight | 92.59 / 100.31 lb |
| AHRI | 207742320 |
Documents & Downloads
- Submittal (This Pairing): CH-RES18-230VO + CH-RS18MDT-MS
- Additional Submittals
- CH-RES18-230VO + CH-PRO18MASTWM-230VI
- CH-RES18-230VO + CH-RH18MASTWM-230VI
- CH-RES18-230VO + CH-RSH18MFC
- CH-RES18-230VO + CH-RSH18MCT
- CH-RES18-230VO + CH-RH18MCT
- Indoor Manuals
- 120N Wire Controller — Owner’s Manual
- Installation Manual — Medium Static Duct
- Owner’s Manual — Medium Static Duct
- SlimDuct Leaflet — R454B
- Outdoor Manuals
- Installation Manual — R454B Outdoor Units
- SlimDuct Leaflet — R454B
Important
- Line set: 1/4" liquid and 1/2" suction (gas).
- Max piping: 98.4 ft total length and 65.6 ft vertical separation.
- Support: hvacsupplies.com/pages/contact • (800) 543-8933
FAQs
What line set size does this system use?
1/4" liquid line and 1/2" suction (gas) line.
What is the maximum piping length and vertical separation?
98.4 ft maximum piping length and 65.6 ft maximum height difference.
How cold can it operate in heating?
Heating ambient range: -13°F to 75°F.
What is the cooling ambient range?
Cooling ambient range: -13°F to 122°F.
What are the outdoor capacity ranges?
Cooling: 17,000 (7,000–19,000) BTU/h. Heating: 20,000 (5,500–22,000) BTU/h.
What is the duct static pressure range?
ESP range: 0–0.4.
What control options are supported?
Remote control and wall thermostat, plus wired controller support.
Does it support app control?
Yes—smart kit connectivity support with app control.