Mini Floor Console + Hyper Outdoor • R454B • 208–230V
Cooper&Hunter 18,000 BTU Hyper Single Zone Floor Console Minisplit Heat Pump System R454B 230V
Overview
This system pairs the CH-RSH16MMC Mini Floor Console indoor unit with the CH-RHP18-230VO Hyper single-zone outdoor unit. The indoor console is designed for versatile comfort delivery with enhanced airflow outlets, plus humidity and refrigerant sensors. The Hyper outdoor unit adds cold-climate heating performance with heating ambient operation listed down to -22°F.
Highlights
- Floor console form factor for flexible placement and room comfort delivery.
- Enhanced airflow outlets designed for more even temperature distribution.
- Inverter-driven outdoor operation for stable temperatures and efficient performance.
System Search
Line Set Size
1/4" Liquid • 1/2" Gas
Max Line Length
98.4 ft
Voltage
208–230V (187–253V)
Outdoor Rated BTU
18,000
Outdoor AHRI
207742320
What’s Included
- Indoor mini floor console: CH-RSH16MMC
- Outdoor condenser (Hyper): CH-RHP18-230VO
- Included remote control + wall thermostat support
- Built-in smart kit capability for app control (setup required)
Video title (not linked): Multi-Zone System with R454B
Indoor Specs (CH-RSH16MMC)
| Spec | Value |
|---|---|
| Refrigerant Type | R454B |
| BTU Rated | 16K |
| SEER2 / EER2 | 20.0 / 12.5 |
| Power | 208–230V • 1Ph • 60Hz (187–253V) |
| Dehumidification | 4.61 pints/day |
| Indoor Airflow | 500.3 / 441.4 / 382.6 / 323.7 |
| Noise (H/M/L) | 43.5 / 40.5 / 30.5 |
| Dimensions (W×D×H) | 31.26 × 7.87 × 24.45 in |
| Net / Gross Weight | 32.85 / 41.89 |
| Line Set | 1/4" Liquid • 1/2" Gas |
| Drain Pipe Diameter | 5/8" |
| Operating Range | Cooling: 60–90°F • Heating: 32–86°F |
| MCA / Max Fuse | 3A / 15A |
| Packing (W×D×H) | 34.06 × 11.02 × 28.31 in |
| Controller | Remote controller |
Outdoor Specs (CH-RHP18-230VO)
| Spec | Value |
|---|---|
| Refrigerant Type | R454B |
| Rated BTU | 18,000 |
| SEER2 / EER2 | 18 / 12 |
| Cooling Capacity (Min/Max) | 17,000 (6,500–18,800) BTU/h |
| Heating Capacity (Min/Max) | 19,000 (8,900–22,000) BTU/h |
| HSPF2 (Region V / IV) | 9 / 10.5 |
| COP | 3.37 |
| Ambient Temperature | Cooling: -22–122°F • Heating: -22–75°F |
| Max Pipe Length / Height Difference | 98.4 ft / 65.6 ft |
| Outdoor Air Flow | 1,765.8 |
| Noise | 59 |
| Dimensions (W×D×H) | 35.04 × 13.46 × 26.50 in |
| Net / Gross Weight | 99.87 / 107.80 |
| MCA / Max Fuse | 19A / 20A |
| Additional Charge (1/4" liquid) | 0.16 |
| AHRI | 207742320 |
Documents & Downloads
- System Submittal (This Combination): CH-RHP18-230VO + CH-RSH16MMC
- Indoor Manuals
- Owner’s Manual — CH-RSH09-16MMC (R454B)
- Installation Manual — CH-RSH09-16MMC (R454B)
- Outdoor Manuals
- Installation Manual — R454B Outdoor Units
- SlimDuct Leaflet (R454B)
- Outdoor Submittals (CH-RHP18-230VO)
- CH-RHP18-230VO + CH-PRO18MASTWM-230VI
- CH-RHP18-230VO + CH-RH18MASTWM-230VI
- CH-RHP18-230VO + CH-RS18MDT-MS
- CH-RHP18-230VO + CH-RS18MAHU
- CH-RHP18-230VO + CH-RSH18MFC
- CH-RHP18-230VO + CH-RH18MCT
- CH-RHP18-230VO + CH-RSH18MCT
Important
- Use the specified line set size: 1/4" liquid and 1/2" suction (gas).
- Confirm circuit sizing and breaker/fuse selection per MCA and local code.
- Support: hvacsupplies.com/pages/contact • (800) 543-8933
FAQs
What line set size is required?
1/4" liquid and 1/2" suction (gas).
How cold can this Hyper system heat?
The outdoor unit’s heating ambient range is listed to -22°F.
What control options are supported?
Remote control, wall thermostat support, and smart kit/app capability (setup required).