Single Zone • 4-Way Ceiling Cassette • R454B • 208–230V
Cooper&Hunter 18,000 BTU Pro Single Zone Four-Way Ceiling Cassette w/ Refrigerant & Humidity Sensor Minisplit Heat Pump System R454B 230V
Overview
An 18K four-way ceiling cassette pairing designed for even airflow distribution, clean-air support, and added diagnostic protection. The CH-RSH18MCT cassette includes refrigerant leakage detection in addition to humidity sensing and self-diagnosis features. Paired with the CH-RES18-230VO regular outdoor unit for efficient, dependable performance and strong SEER2.
Highlights
- Omni-directional airflow and 360° panel helps distribute air evenly throughout the room.
- Activated carbon filtration support for fresher indoor air.
- Refrigerant leakage detection helps protect the system in abnormal conditions.
- Built-in pump with float switch (20.9" lift) for quiet condensate removal.
- Turbo operation, sleep mode, and multiple fan speeds for comfort tuning.
- Regular outdoor unit supports heating operation down to -13°F ambient.
Indoor Model
Outdoor Model
Line Set Size
1/4" Liquid • 1/2" Gas
Outdoor SEER2
20.7
Max Line Length
98.4 ft
Low-Ambient Heating
Down to -13°F
What’s Included
- Indoor 4-way ceiling cassette: CH-RSH18MCT
- Outdoor condenser: CH-RES18-230VO (Regular)
- Remote control (indoor control package)
- Ceiling Cassette Panel
- Built-in condensate pump with float switch (indoor)
- Smart Kit capability for app control (setup required)
Indoor Specs (CH-RSH18MCT)
| Spec | Value |
|---|---|
| Refrigerant Type | R454B |
| System Type | Single Zone |
| BTU Rated | 18,000 |
| Power | 208–230V • 1Ph • 60Hz (Voltage Range: 187–253V) |
| SEER2 / EER2 | 20 / 12.5 |
| Dehumidification | 4.23 pints/day |
| Indoor Airflow (CFM) | 447.3 / 388.5 / 317.8 / 194.2 |
| Noise (dB(A)) | 44.5 / 41 / 27.5 (H/M/L) |
| Unit Dimensions (W×D×H) | 22.44 × 22.44 × 9.65 in |
| Net / Gross Weight | 35.27 / 41.89 lb |
| Refrigerant Piping | 1/4" Liquid • 1/2" Gas |
| Drain Pipe Diameter | 1" |
| Operating Range | Cooling: 60–90°F • Heating: 32–86°F |
| Minimum Circuit Ampacity | 3 A |
| Max Fuse | 15 A |
Outdoor Specs (CH-RES18-230VO)
| Spec | Value |
|---|---|
| Refrigerant Type | R454B |
| System Type | Single-zone unit |
| BTU Rated | 18,000 |
| Cooling Capacity (Min–Max) | 17,000 (7,000–19,000) BTU/h |
| Heating Capacity (Min–Max) | 20,000 (5,500–22,000) BTU/h |
| SEER2 / EER2 | 20 / 12.5 |
| HSPF2 (Region IV / V) | 10.5 / 8.2 |
| COP | 3.47 |
| Power | 208–230V • 1Ph • 60Hz (Voltage Range: 187–253V) |
| Max Pipe Length | 98.4 ft |
| Max Height Difference | 65.6 ft |
| Minimum Circuit Ampacity | 18 A |
| Max Fuse | 20 A |
| Outdoor Airflow | 1,765.8 CFM |
| Outdoor Noise | 59 dB(A) |
| Unit Dimensions (W×D×H) | 35.04 × 13.46 × 26.5 in |
| Net / Gross Weight | 92.59 / 100.31 lb |
| Ambient Temperature | Cooling: -13–122°F • Heating: -13–75°F |
| Additional Charge | 0.16 oz/ft (1/4" liquid line) |
Documents & Downloads
- Submittal Sheet: CH-RES18-230VO + CH-RSH18MCT
- Submittal Sheet: CH-RES18-230VO + CH-PRO18MASTWM-230VI
- Submittal Sheet: CH-RES18-230VO + CH-RH18MASTWM-230VI
- Submittal Sheet: CH-RES18-230VO + CH-RS18MDT
- Submittal Sheet: CH-RES18-230VO + CH-RSH18MFC
- Outdoor Units Installation Manual (R454B)
- SlimDuct Leaflet (R454B)
- 120N Wire Controller — Uses & Installation Manual
- Ceiling Cassette Installation Manual (R454B)
- Ceiling Cassette Owner’s Manual (R454B)
- MultiZone Combination Guide — Hyper
- MultiZone Combination Guide — Regular
- Submittal Sheet: CH-RES18-230VO + CH-RH18MCT
Important
- Professional installation is recommended.
- Match line set sizes to the equipment: 1/4" liquid and 1/2" suction.
- Verify the dedicated circuit is sized per equipment MCA and local code.
- For help choosing equipment, contact us: hvacsupplies.com/pages/contact • (800) 543-8933
FAQs
What is the difference between RH and RSH cassettes?
RSH models add refrigerant leakage detection in addition to standard monitoring features.
What line set sizes are required for this 18K cassette?
1/4" liquid line and 1/2" suction (gas) line.
How cold can the regular outdoor unit operate in heating?
CH-RES18-230VO supports heating operation down to -13°F ambient.
Does the indoor cassette include a condensate pump?
Yes. CH-RSH18MCT includes a built-in pump with float switch (20.9" lift).