Cooper&Hunter 12,000 BTU Olivia Single Zone Wall Mount Mini Split Heat Pump System R410A 230V
SKU: CH-12MOLVWM-230VI + CH-ES12-230VO
Overview
Enhance everyday comfort with the Cooper&Hunter 12,000 BTU Olivia wall-mounted mini split heat pump system. This configuration is a single-zone system designed for 208–230V applications, delivering efficient inverter-driven cooling and heating with quiet, steady performance.
Olivia comfort features include Auto-Swing horizontal louvers for even air distribution, Follow Me mode for remote-sensed temperature control, plus Sleep and Timer functions for daily convenience. The system also includes 46° Freeze Protection. App control is available when paired with an optional WiFi/Smart Kit (sold separately).
Highlights
- Efficient inverter comfort: smooth capacity control for consistent temperatures and reduced cycling.
- Even airflow: auto-swing horizontal louvers help distribute air more uniformly.
- Convenient control: included remote; optional app control with WiFi/Smart Kit (sold separately).
- Cold-weather protection: 46° Freeze Protection support for added peace of mind.
What’s Included
- Indoor unit: CH-12MOLVWM-230VI
- Outdoor unit: CH-ES12-230VO
- Remote control (included)
- Manufacturer documentation (see Documents & Downloads)
- Installation kit is not included unless selected in the Variant Options (No installation, 16ft, 25ft, 50ft).
Indoor Specs
| Spec | Details |
|---|---|
| Model | CH-12MOLVWM-230VI |
| System type | Single Zone |
| BTU rated | 12,000 |
| Power source | 208–230V, 1Ph, 60Hz |
| Voltage range | 187–253 V |
| SEER2 | 23.1 |
| EER2 | 13 |
| Refrigerant piping (liq/gas) | 1/4" / 1/2" |
| Minimum circuit ampacity | 3 |
| Max fuse | 15 |
| Indoor noise level (H/M/L) | 41.5 / 36 / 24 dB(A) |
| Indoor air flow | 341.18 / 291.18 / 194.12 / 152.94 CFM |
| Dehumidification | 3.06 pnt/day |
| Controller | RG10K-exclusive remote |
| Unit dimensions (W×H×D) | 31.57 × 7.87 × 11.61 in |
| Net / Gross weight | 18.74 / 24.25 lb |
| Packing dimensions (W×D×H) | 34.45 × 11.22 × 14.96 in |
| Drain pipe diameter | 5/8" |
| Operating range (Cooling) | 60–90°F |
| Operating range (Heating) | 32–86°F |
Outdoor Specs
| Spec | Details |
|---|---|
| Model | CH-ES12-230VO |
| System type | Single Zone |
| Refrigerant type | R410A |
| BTU rated | 12,000 |
| Power source | 208–230V, 1Ph, 60Hz |
| Voltage range | 187–253 V |
| Refrigerant piping (liq/gas) | 1/4" / 1/2" |
| Max pipe length | 82.02 ft |
| Max height difference (IDU↔ODU) | 32.81 ft |
| Cooling capacity (Min/Max) | 11,500 (2,100–13,450) BTU/h |
| Heating capacity (Min/Max) | 12,000 (1,900–15,000) BTU/h |
| SEER2 | 19 |
| EER2 | 11.7 |
| HSPF2-5 | 7.8 |
| HSPF2-4 | 10.3 |
| COP | 3.52 |
| Outdoor noise level | 53.5 dB(A) |
| Outdoor air flow | 1,294.12 CFM |
| Dehumidification | 3.38 pnt/day |
| Minimum circuit ampacity | 13 |
| Max fuse | 15 |
| Ambient temp (Heating) | −13–75°F |
| Ambient temp (Cooling) | −13–122°F |
| Unit dimensions (W×H×D) | 30.12 × 11.93 × 21.85 in |
| Net / Gross weight | 63.71 / 69.00 lb |
| Packing dimensions (W×D×H) | 34.92 × 13.27 × 24.02 in |
| Refrigerant precharge | 25 ft |
| Additional charge (1/4" liquid) | 0.16 oz/ft |
Documents & Downloads
- Submittal (PDF) — CH-ES12-230VO + CH-12MOLVWM-230VI
- Submittal (PDF) — CH-12MOLVWM-230VI
- Submittal (PDF) — Hyper pairing option (CH-HPR12-230VO + CH-12MOLVWM-230VI)
- Olivia Leaflet (PDF) — 2024
- Accessories Leaflet (PDF) — 2023
- Installation Manual (PDF)
- Owner’s Manual (PDF)
- Remote Manual (PDF)
- Remote Manual Content (PDF)
- AHRI Directory Listing — AHRI #207742320
Videos
Mini-split installation videos
- How to Install Mini Split Cooper&Hunter
- How to Install Multi Zone Mini Split System (Cooper&Hunter) 2020
- Full Installation of Mini Split Ductless Unit, Step by Step!
How To & Instructional Videos
- How to Clean Cooper&Hunter Mini Split Wall Mount A/C
- Top Tips from Cooper&Hunter Mini Split User Manual
- Mini Split WiFi Set Up (Cooper&Hunter)
- Cooper&Hunter New Remote Control (2022)
Products overview
- Cooper&Hunter: Multi Zone AC for the Home
- Multi-Zone Mini-Split System vs Central A/C in Home (2019) Cooper&Hunter
- Cooper&Hunter Products at AHR Expo 2020 with Robot Millennia
- HVAC Installation Kit: 99.9% Copper Line Sets (Cooper&Hunter)
- Mini Split Indoor Unit Types Explained
- Cooper&Hunter Olivia Series
Mini-Splits
- Can You Use a Mini Split in EXTREME COLD? Heat Pump vs. Propane Cost Comparison with Thermal Camera
- Where To Mount a Mini Split Indoor Wall Hung Unit
- How To Wall Mount a Mini Split Outdoor Condenser Unit
- Are Mini Split Air Conditioners Worth It? - Top 5 Pros & Cons
- Does a Wall Mounted MINISPLIT Need a CONDENSATE TRAP? Ductless vs Ducted Air Handlers!
- MINI SPLIT Parts Explained! Understand What They Do!
- Mini Split Failure from Electrical Surges, High and Low Voltage! HOW TO SOLVE IT!
- Full Installation of an Inverter Minisplit Heat Pump with Indoor Ceiling Cassette
- Checking the Refrigerant Charge on a Running R-410A Inverter MINI SPLIT Unit
- Mini Split Indoor Unit Types Explained! 5 Types- Applications, Connection Points, Mounting!
Important
Professional installation is recommended. Confirm electrical requirements, line sizes, maximum line length, and ambient operating limits before installation. Installation kits are not included unless selected in the Variant Options (No installation, 16ft, 25ft, 50ft).
FAQs
Is this system single-zone?
What line sizes does this system use?
What is the max line length and height difference?
Can I control it with an app?
What is the outdoor heating and cooling ambient range?
Are installation kits included?