Cooper&Hunter 10kW Auxiliary Heater, Electrical Heater, and Heat Strip for Multi-Position Air Handler (CH-NREH10KW)

SKU: CH-NREH10KW

System highlights
AC Type
Parts
Brand
Cooper&Hunter
Looking For
Electric Heat Kit
Electric Heat
10 Kilowatt
Regular price $223.00 USD
Regular price Sale price $223.00 USD
Sale Sold out
Shipping calculated at checkout.
Quantity
View full details
Cooper&Hunter logo

Cooper&Hunter R454B 10kW Auxiliary Heater / Heat Strip for Multi-Position Air Handler (CH-NREH10KW)

10kW auxiliary electric heater kit for compatible Cooper&Hunter R454B Multi-Position air handlers. Optional backup heat for emergencies or when primary heat pump output is reduced in low outdoor temperatures.

SKU: CH-NREH10KW 10kW auxiliary heat R454B Multi-Position AHU only One group (10kW + 5kW) W1 on 10kW

Compatibility is strictly for the Multi-Position Air Handler that uses R454B refrigerant. Verify the air handler model before ordering.

Custom quotes & questions

Overview

  • 10kW auxiliary electric heat for compatible Cooper&Hunter R454B Multi-Position air handlers.
  • Optional backup heat for indoor units during emergencies or when the primary heating system is not operating.
  • Supports additional comfort in cold weather as supplemental / staged heat (system and thermostat dependent).
  • Group configuration: One group (10kW + 5kW) with W1 on 10kW.

Model

CH-NREH10KW

Auxiliary heater / heat strip kit

Configuration

One group (10kW + 5kW)

W1 on 10kW

Compatibility

R454B Multi-Position AHU

Verify AHU model before ordering

Heater staging and controls depend on the air handler control board and thermostat wiring (W1/W2).

Highlights

  • 10kW heating output for stronger supplemental electric heat vs. smaller heat strip kits.
  • Designed for Cooper&Hunter Multi-Position Air Handlers using R454B refrigerant.
  • Backup heat option for emergency situations when the primary heat source is unavailable.
  • Cold weather support when heat pump capacity is reduced at low outdoor temperatures.
  • Professional install recommended (electrical wiring and code-compliant circuit sizing required).

Compatibility

Air handler (AHU) capacity compatibility

CH-NREH10KW (10kW) is approved for the following R454B Multi-Position AHU sizes:

AHU Capacity 18K 24K 30K 36K 48K 60K
10kW Heater (CH-NREH10KW) Y Y Y Y Y Y

Because the 10kW kit is approved across 18K–60K AHU capacities, it is commonly selected for larger ducted air handler sizes.

System tonnage reference (electric heat availability)

For the listed R454B Multi-Position AHU models below, 10kW auxiliary heat is available from 1.5–6 ton.

Electric Heater 1.5 ton
(18,000 BTU/h)
2 ton
(24,000 BTU/h)
3 ton
(30,000 BTU/h)
4 ton
(36,000 BTU/h)
5 ton
(48,000 BTU/h)
6 ton
(60,000 BTU/h)
AHU Model CH-RS18MAHU CH-RS24MAHU CH-RS30MAHU CH-RS36LCAHU CH-RS48LCAHU CH-RS60LCAHU
10kW (CH-NREH10KW) Y Y Y Y Y Y

Always confirm the exact indoor air handler model and the heater-kit part number prior to installation.

Important

  • R454B AHU only: This heater kit is only compatible with the Multi-Position Air Handler platform using R454B refrigerant.
  • Not universal: Do not assume compatibility across other refrigerants, air handler generations, or brands.
  • Electrical safety: Installation requires correct circuit sizing, grounding, and adherence to local codes.
  • Controls/staging: Group configuration is one group (10kW + 5kW) with W1 on 10kW. Thermostat wiring and control board logic determine staging behavior.

FAQs

What is the CH-NREH10KW used for?
It’s a 10kW auxiliary electric heat strip kit for compatible Cooper&Hunter R454B Multi-Position air handlers, used as backup or supplemental heat.
Is this compatible with all AHU sizes?
The 10kW kit is approved for 18K, 24K, 30K, 36K, 48K, and 60K AHU capacities on the R454B Multi-Position platform.
How is the 10kW kit staged?
The kit is configured as one group (10kW + 5kW) with W1 on 10kW. Actual staging depends on thermostat wiring and the air handler control board.
Do I need a licensed installer?
Professional installation is recommended. This is line-voltage equipment and must be installed per the installation instructions, equipment nameplate, and local code.

Questions or a project quote?