Skip to product information
1 of 1

ACIQ

ACIQ 80% 60,000 BTU Single Stage Ultra-Low NOx Gas Furnace - 17.5" Width - Upflow/Horizontal

SKU: AQ-GR9S800604BU

System highlights
AC Type
Gas Furnaces
Brand
ACIQ
Voltage
110V
Looking For
Gas Furnaces
Features
New Refrigerant Compliant, Ultra-Low NOx
Airflow Direction
Upflow, Horizontal
Blower Motor
9-Speed
Maximum CFM
1600
Fuel Type
Natural Gas, Propane
Burner Stages
Single Stage
Phase
Single Phase
Furnace Heating BTU
60,000 BTU (5.00 Ton)
Furnace Efficiency
80% AFUE
Cabinet Width (in)
17 1/2

Price

$1,962.00
Shipping calculated at checkout.
Quantity
View full details
ACIQ
ACIQ 80% 60,000 BTU Single Stage Ultra-Low NOx Gas Furnace - 17.5" Width - Upflow/Horizontal

Product Overview

OVERVIEW

The AQ-GR9S800604BU ACiQ gas furnace features high-quality construction and efficient operation at a great value. The AQ-GR9S800604BU single-stage, 9-speed furnace utilizes ACiQ superior heat exchanger design to provide efficient, reliable heating to your home. If you're looking to cut your energy bills and improve your comfort without breaking the bank, your search stops with the ACiQ AQ-GR9S800604BU.

QUICK FACTS

  • This furnace is ideal to heat a smaller house (depending on climate)
  • 60,000 BTU 80% efficient natural gas furnace
  • Requires metal flue venting
  • Can be used in the downflow or horizontal (right or left) orientation
  • Ultra-Low NOx Compliant for California
  • Innovative design for electrical efficiency, safety, and lower sound output

60,000 BTU

The AQ-GR9S800604BU ACiQ gas furnace is 60,000 BTU's. This BTU count is a measure of the input of the furnace per hour, while the output of this furnace is 48,000 BTU's (60,000 X 80% AFUE) per hour. In ideal climate conditions, this 60,000 BTU furnace is usually used to heat a small house.

80% Efficiency Rating

The AQ-GR9S800604BU ACiQ gas furnace is 80% efficient, and the standard furnace efficiency on the market today. This means that 80% of the gas going into the furnace is used to heat your home and the remaining 20% is lost out of the flue venting. Please note that all 80% furnaces must be vented using metal flue venting, while anything higher than 90% efficient must be vented using plastic/PVC venting.

Single Stage Furnace

The AQ-GR9S800604BU ACiQ gas furnace is a single stage furnace has only one heat output. Regardless of the indoor temperature, this furnace will burn at 100% output whenever the thermostat calls for it. Like a light switch, this furnace's burner will either be on or off and nothing in between. A single stage furnace is the standard efficient furnace since every time your furnace turns on the furnace uses the same amount of energy.

9-Speed ECM Blower Motor

Instead of the last generation PSC blower motor, the AQ-GR9S800604BU utilizes a multi-speed ECM motor, which uses less power and provides smarter air circulation. All of this causes an overall increase in the electrical efficiency of your furnace, which saves you money.

Warranty

With installation that follows your state and local codes and with online registration, all ACiQ furnaces come with a 10-year parts and lifetime heat exchanger warranty through the manufacturer.

Durable Hot Surface Igniter

The hot surface igniter on modern ACiQ furnaces are more durable than previous designs, decreasing related issues and lowering maintenance costs. These hot surface ignitors are also more efficient than standing pilot and older HSI designs, saving you even more money.

Self-Diagnostic Control Board

The ACiQ brand has improved technology from years of production experience, allowing for a long-lasting product that rarely has any issues. However, if something does go wrong on the furnace, the control board has a set of sensors that allow it to diagnose basic issues, allowing for easy troubleshooting and to notify the owner if basic maintenance or warranty work is recommended. This increases the overall safety of the unit, for the furnace itself and the occupants of the home where it is installed.

Heavy Gauge Steel Cabinet

The heavy-gauge steel cabinet on new ACiQ furnaces provide adequate protection to the internal mechanisms of the unit. The cabinet is also more air-tight than previous models, allowing for a quiet, more economical unit due to losing less heat and preventing more sound from exiting the unit.

Ease of Installation

The value of modern ACiQ furnaces doesn't end at efficiency. Today's ACiQ furnaces feature many different connection options to reduce installation. The AQ-GR9S800604BU model has a more universal design, which consists of its ability to be installed in both an downflow or horizontal (right or left) configuration. This allows for an easier installation in more locations, from your attic to your basement. The furnace also comes with color-coded low-voltage terminals that allow for a shorter and easier installation time, which decreases installation costs.

Technical Specifications — AQ-GR9S800604BU

sku AQ-GR9S800604BU
weight (in lbs) 90.000000
ahri certificate number 207599841
airflow direction Upflow/Horizontal
exhaust flue requirement Metal
brand/manufacturer Private Brand
product features New Refrigerant Compliant, Ultra-Low NOx
furnace efficiency / afue 80%
heating btu 60,000
blower motor 9 Speed
maximum cfm 1600
horsepower 3/4 HP
configuration Upflow/Horizontal
electrical 110 V. 1 Phase 60 Hz
phase Single Phase
max breaker size 20 Amps
min. breaker size 12.7 Amps
low nox Ultra Low NOx
burner stages Single
fuel type Natural Gas
height 33 3/8"
width 17 1/2"
depth 28"
warranty 10 Years with Online Registration
safety information This gas appliance requires a trained technician to install. Improperly connecting gas lines or improperly connecting a gas flue or venting may result in death. By purchasing this item, you are agreeing that you are using a trained technician to install this gas appliance. We will not be responsible for any injury or property damage arising from improper service or service procedures. Whoever installs or services this unit assumes responsibility for any personal injury or property damage which may result. Many jurisdictions require a license to install this equipment.PROPOSITION 65 WARNINGThis product and many products on our site may contain a chemical know to the state of California to cause cancer or birth defects or other reproductive harm. For more information about Proposition 65 pleaseClick Here.

Warranty