{"product_id":"cooper-hunter-slim-duct-ducted-mini-split-ac-indoor-unit-9-000-btu-r410a","title":"Cooper\u0026Hunter Slim Duct Ducted Mini Split AC Indoor Unit – 9,000 BTU | R410A","description":"\u003cstyle\u003e\n  :root{\n    --hvx-golden:#FAA819;\n    --hvx-slate:#262626;\n    --hvx-ivory:#F4F1E6;\n    --hvx-border:#e2e0d5;\n    --hvx-card-bg:#ffffff;\n  }\n\n  .hvx-desc{\n    font-family:\"Articulat CF\",system-ui,-apple-system,BlinkMacSystemFont,\"Segoe UI\",sans-serif;\n    color:var(--hvx-slate);\n    line-height:1.6;\n    background:var(--hvx-ivory);\n    padding:18px 18px 20px;\n    border-radius:16px;\n  }\n\n  .hvx-desc-header{\n    border-radius:14px;\n    padding:14px 16px;\n    background:linear-gradient(120deg,var(--hvx-golden),var(--hvx-slate));\n    color:#fff;\n    margin:0 0 16px;\n    box-shadow:0 10px 24px rgba(0,0,0,.22);\n    display:flex;\n    align-items:flex-start;\n    gap:12px;\n    flex-wrap:wrap;\n  }\n\n  .hvx-header-text{display:flex;flex-direction:column;gap:6px;min-width:260px}\n  .hvx-eyebrow{\n    font-size:11px;\n    letter-spacing:.14em;\n    text-transform:uppercase;\n    opacity:.9;\n  }\n  .hvx-title{\n    margin:0;\n    font-family:\"Anton\",\"Impact\",system-ui,-apple-system,BlinkMacSystemFont,\"Segoe UI\",sans-serif;\n    font-size:22px;\n    line-height:1.15;\n  }\n  .hvx-subtitle{\n    margin:0;\n    font-size:14px;\n    opacity:.95;\n  }\n\n  .hvx-desc-card{\n    border:1px solid var(--hvx-border);\n    border-radius:14px;\n    background:var(--hvx-card-bg);\n    padding:16px 18px 18px;\n    box-shadow:0 4px 12px rgba(0,0,0,.06);\n    margin:14px 0;\n  }\n\n  .hvx-section-title{\n    margin:0 0 10px;\n    font-family:\"Anton\",\"Impact\",system-ui,-apple-system,BlinkMacSystemFont,\"Segoe UI\",sans-serif;\n    font-size:17px;\n    letter-spacing:.08em;\n    text-transform:uppercase;\n    color:var(--hvx-slate);\n    display:inline-flex;\n    align-items:center;\n    gap:8px;\n  }\n  .hvx-section-title::after{\n    content:\"\";\n    flex:1;\n    height:2px;\n    border-radius:999px;\n    background:linear-gradient(90deg,var(--hvx-golden),transparent);\n    opacity:.9;\n  }\n\n  .hvx-cta{display:flex;flex-wrap:wrap;gap:10px;margin:10px 0 0}\n  .hvx-cta a{\n    display:inline-flex;\n    align-items:center;\n    gap:8px;\n    padding:10px 14px;\n    border-radius:12px;\n    border:1px solid var(--hvx-border);\n    background:#fff;\n    text-decoration:none;\n    color:var(--hvx-slate);\n    font-size:14px;\n    font-weight:700;\n  }\n  .hvx-cta a.primary{\n    background:var(--hvx-slate);\n    color:#fff;\n    border-color:transparent;\n  }\n\n  .hvx-badges{display:flex;flex-wrap:wrap;gap:8px;margin:10px 0 0}\n  .hvx-badge{\n    font-size:12px;\n    border:1px solid var(--hvx-border);\n    border-radius:999px;\n    padding:6px 10px;\n    background:#fff;\n    white-space:nowrap;\n  }\n\n  .hvx-kv{\n    display:grid;\n    grid-template-columns:repeat(4,minmax(160px,1fr));\n    gap:10px;\n    margin-top:10px;\n  }\n  .hvx-kv \u003e div{\n    border:1px solid var(--hvx-border);\n    background:#fff;\n    border-radius:12px;\n    padding:10px 12px;\n    text-align:center;\n  }\n  .hvx-kv strong{display:block}\n\n  .hvx-table{\n    width:100%;\n    border-collapse:collapse;\n    min-width:520px;\n    background:#fff;\n    border:1px solid var(--hvx-border);\n    border-radius:12px;\n    overflow:hidden;\n  }\n  .hvx-table th,.hvx-table td{\n    border-bottom:1px solid var(--hvx-border);\n    padding:10px 12px;\n    vertical-align:top;\n    font-size:14px;\n  }\n  .hvx-table th{ text-align:left; font-weight:800; background:#fff; }\n  .hvx-table tr:nth-child(even) td{ background:#fbfaf6; }\n  .hvx-table tr:last-child td{ border-bottom:none; }\n  .hvx-table-wrap{ overflow:auto; border-radius:12px; }\n\n  .hvx-link{color:var(--hvx-slate); text-decoration:underline; text-underline-offset:2px}\n  .hvx-link:hover{opacity:.85}\n\n  details.hvx-faq{\n    border:1px solid var(--hvx-border);\n    background:#fff;\n    border-radius:12px;\n    padding:10px 12px;\n    margin:8px 0;\n  }\n  details.hvx-faq summary{cursor:pointer;font-weight:800;}\n\n  @media(max-width:980px){\n    .hvx-kv{grid-template-columns:repeat(2,minmax(160px,1fr))}\n  }\n  @media(max-width:768px){\n    .hvx-desc{padding:14px 12px 16px;border-radius:12px}\n    .hvx-desc-header{padding:12px;border-radius:12px}\n    .hvx-title{font-size:19px}\n    .hvx-desc-card{padding:14px;margin:10px 0}\n  }\n\u003c\/style\u003e\n\u003cdiv class=\"hvx-desc\"\u003e\n\u003cdiv class=\"hvx-desc-header\"\u003e\n\u003cdiv class=\"hvx-header-text\"\u003e\n\u003cdiv class=\"hvx-eyebrow\"\u003eCooper\u0026amp;Hunter Slim Duct Indoor • R410A • 230V • Single\/Multi-Zone\u003c\/div\u003e\n\u003ch1 class=\"hvx-title\"\u003eCooper\u0026amp;Hunter 9,000 BTU Slim Duct Ducted Indoor Unit — CH-M09DTUI\u003c\/h1\u003e\n\u003cp class=\"hvx-subtitle\"\u003eLow-profile concealed ducted air handler designed for attics and ceiling crawl spaces, offering zone-style comfort without central-system duct losses.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv aria-label=\"Contact options\" class=\"hvx-cta\"\u003e\n\u003ca title=\"Contact Us\" rel=\"noopener\" href=\"https:\/\/hvacsupplies.com\/pages\/contact\" class=\"primary\" target=\"_blank\"\u003eCLICK HERE TO CONTACT US FOR CUSTOM QUOTES AND QUESTIONS\u003c\/a\u003e \u003ca title=\"Call Us Now!\" href=\"tel:+18005438933\"\u003eCLICK TO CALL US 1-800-543-8933 FOR ANY QUESTIONS\u003c\/a\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"hvx-desc-card\"\u003e\n\u003ch2 class=\"hvx-section-title\"\u003eOverview\u003c\/h2\u003e\n\u003cp style=\"margin: 0;\"\u003eCooper\u0026amp;Hunter \u003cstrong\u003eSlim Duct\u003c\/strong\u003e indoor units provide an inconspicuous ducted solution by hiding the air handler in \u003cstrong\u003eattics\u003c\/strong\u003e or \u003cstrong\u003eceiling crawl spaces\u003c\/strong\u003e, delivering comfort to one or more areas without the energy losses commonly associated with traditional central ducted systems. Duct runs can be directed into separate areas that are \u003cstrong\u003ecollectively controlled by a single wall thermostat\u003c\/strong\u003e (controller\/system dependent). \u003cbr\u003e\u003cbr\u003eThe \u003cstrong\u003eCH-M09DTUI\u003c\/strong\u003e is a \u003cstrong\u003e9,000 BTU\u003c\/strong\u003e slim-duct indoor unit designed for \u003cstrong\u003esingle-zone\u003c\/strong\u003e or compatible \u003cstrong\u003emulti-zone\u003c\/strong\u003e applications in \u003cstrong\u003e208–230V\u003c\/strong\u003e systems. It supports multiple control methods, including the included remote and compatibility with wired controllers (120X\/120N).\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"hvx-desc-card\"\u003e\n\u003ch2 class=\"hvx-section-title\"\u003eHighlights\u003c\/h2\u003e\n\u003cdiv role=\"list\" class=\"hvx-badges\"\u003e\n\u003cspan role=\"listitem\" class=\"hvx-badge\"\u003e9,000 BTU (rated)\u003c\/span\u003e \u003cspan role=\"listitem\" class=\"hvx-badge\"\u003eSEER2 20.2\u003c\/span\u003e \u003cspan role=\"listitem\" class=\"hvx-badge\"\u003eEER2 13.2\u003c\/span\u003e \u003cspan role=\"listitem\" class=\"hvx-badge\"\u003eConcealed Slim Duct\u003c\/span\u003e \u003cspan role=\"listitem\" class=\"hvx-badge\"\u003eESP 0–0.32\u003c\/span\u003e \u003cspan role=\"listitem\" class=\"hvx-badge\"\u003eWired Controller Compatible\u003c\/span\u003e \u003cspan role=\"listitem\" class=\"hvx-badge\"\u003eRG10K Remote Included\u003c\/span\u003e \u003cspan role=\"listitem\" class=\"hvx-badge\"\u003eSingle\/Multi-Zone Compatible\u003c\/span\u003e\n\u003c\/div\u003e\n\u003cul style=\"margin: 12px 0 0; padding-left: 18px;\"\u003e\n\u003cli\u003e\n\u003cstrong\u003eHidden installation:\u003c\/strong\u003e Designed for tight locations like attics and ceiling crawl spaces.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFlexible ducting:\u003c\/strong\u003e Route supply ducts into multiple areas that share one thermostat\/controller (system dependent).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eStatic pressure capability:\u003c\/strong\u003e \u003cstrong\u003eESP range 0–0.32\u003c\/strong\u003e supports a variety of duct layouts.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eComfort vs. noise:\u003c\/strong\u003e Indoor sound levels as low as \u003cstrong\u003e27 dB(A)\u003c\/strong\u003e (low).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eControls:\u003c\/strong\u003e RG10K remote and compatibility with 120X\/120N wired controllers.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cdiv aria-label=\"At-a-glance\" role=\"list\" class=\"hvx-kv\"\u003e\n\u003cdiv role=\"listitem\"\u003e\n\u003cstrong\u003eModel\u003c\/strong\u003eCH-M09DTUI\u003c\/div\u003e\n\u003cdiv role=\"listitem\"\u003e\n\u003cstrong\u003eSystem Type\u003c\/strong\u003eSingle\/Multi-Zone\u003c\/div\u003e\n\u003cdiv role=\"listitem\"\u003e\n\u003cstrong\u003eLine Set\u003c\/strong\u003e1\/4\" (liq) \/ 3\/8\" (gas)\u003c\/div\u003e\n\u003cdiv role=\"listitem\"\u003e\n\u003cstrong\u003eSound (H\/M\/L)\u003c\/strong\u003e33.5\/28.5\/27 dB(A)\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"hvx-desc-card\"\u003e\n\u003ch2 class=\"hvx-section-title\"\u003eWhat's Included\u003c\/h2\u003e\n\u003cul style=\"padding-left: 18px; margin: 8px 0;\"\u003e\n\u003cli\u003eSlim duct indoor unit: \u003cstrong\u003eCH-M09DTUI\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003eRemote control: \u003cstrong\u003eRG10K-exclusive\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"hvx-desc-card\"\u003e\n\u003ch2 class=\"hvx-section-title\"\u003eIndoor Specs\u003c\/h2\u003e\n\u003cdiv class=\"hvx-table-wrap\"\u003e\n\u003ctable aria-label=\"Indoor unit specifications\" class=\"hvx-table\"\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eSpec\u003c\/th\u003e\n\u003cth\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCH-M09DTUI\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSystem Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSingle\/Multi-zone unit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBTU Rated\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e9,000\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower Source\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e208–230V, 1Ph, 60Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eVoltage Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e187–253 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSEER2 \/ EER2\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e20.2 \/ 13.2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMinimum Circuit Ampacity (MCA)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1.3 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMax Fuse\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e15 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDehumidification\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2.11 pints\/day\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eController\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eRG10K-exclusive remote \u0026amp; 120X or 120N wire controller\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRefrigerant Piping (Liquid \/ Gas)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1\/4\" \/ 3\/8\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIndoor Noise (H\/M\/L)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e33.5 \/ 28.5 \/ 27 dB(A)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIndoor Air Flow\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e352.94 \/ 282.35 \/ 176.47\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eESP Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0–0.32\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eUnit Dimensions (W×H×D)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e27.56 × 19.92 × 7.87 in\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eUnit Net \/ Gross Weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e39.02 \/ 48.28 lb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePacking Dimensions (W×D×H)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e33.86 × 21.26 × 11.22\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDrain Pipe Diameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperation Range (Cooling)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e62–90 °F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperation Range (Heating)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e32–86 °F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"hvx-desc-card\"\u003e\n\u003ch2 class=\"hvx-section-title\"\u003eVideos\u003c\/h2\u003e\n\u003cdiv style=\"margin: 8px 0 0;\"\u003e\n\u003cdiv style=\"font-weight: 800; margin: 10px 0 6px;\"\u003eMini-split installation videos\u003c\/div\u003e\n\u003cul style=\"padding-left: 18px; margin: 0;\"\u003e\n\u003cli\u003e\u003ca rel=\"noopener\" href=\"https:\/\/youtu.be\/hDEhQ94r2rQ\" class=\"hvx-link\" target=\"_blank\"\u003eHow to Install Mini Split Cooper\u0026amp;Hunter\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca rel=\"noopener\" href=\"https:\/\/youtu.be\/ieOdKq8yBKY\" class=\"hvx-link\" target=\"_blank\"\u003eCooper\u0026amp;Hunter Mini Split Slim Duct Installation\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca rel=\"noopener\" href=\"https:\/\/youtu.be\/JQkth-AM5CE\" class=\"hvx-link\" target=\"_blank\"\u003eFull Installation of Mini Split Ductless Unit, Step by Step!\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"margin: 12px 0 0;\"\u003e\n\u003cdiv style=\"font-weight: 800; margin: 10px 0 6px;\"\u003eHow To \u0026amp; Instructional Videos\u003c\/div\u003e\n\u003cul style=\"padding-left: 18px; margin: 0;\"\u003e\n\u003cli\u003e\u003ca rel=\"noopener\" href=\"https:\/\/youtu.be\/7mzwevkxw20\" class=\"hvx-link\" target=\"_blank\"\u003eTop Tips from Cooper\u0026amp;Hunter Mini Split User Manual\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"margin: 12px 0 0;\"\u003e\n\u003cdiv style=\"font-weight: 800; margin: 10px 0 6px;\"\u003eProducts overview\u003c\/div\u003e\n\u003cul style=\"padding-left: 18px; margin: 0;\"\u003e\n\u003cli\u003e\u003ca rel=\"noopener\" href=\"https:\/\/youtu.be\/TCcju8Ii6L8\" class=\"hvx-link\" target=\"_blank\"\u003eMulti-Zone Mini-Split System vs Central A\/C in Home (2019) Cooper\u0026amp;Hunter\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca rel=\"noopener\" href=\"https:\/\/youtu.be\/k6CLIFdvVXk\" class=\"hvx-link\" target=\"_blank\"\u003eCooper\u0026amp;Hunter Products at AHR Expo 2020 with Robot Millennia\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca rel=\"noopener\" href=\"https:\/\/youtu.be\/2u0pa2jThCM\" class=\"hvx-link\" target=\"_blank\"\u003eHVAC Installation Kit: 99.9% Copper Line Sets (Cooper\u0026amp;Hunter)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca rel=\"noopener\" href=\"https:\/\/youtu.be\/qCWu8HCNl3Q\" class=\"hvx-link\" target=\"_blank\"\u003eMini Split Indoor Unit Types Explained\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"hvx-desc-card\"\u003e\n\u003ch2 class=\"hvx-section-title\"\u003eDocuments \u0026amp; Downloads\u003c\/h2\u003e\n\u003cul style=\"padding-left: 18px; margin: 8px 0;\"\u003e\n\u003cli\u003e\u003ca rel=\"noopener\" href=\"https:\/\/media.cooperandhunter.us\/3200\/CH-M09DTUI.pdf\" class=\"hvx-link\" target=\"_blank\"\u003eSubmittal — CH-M09DTUI (PDF)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca rel=\"noopener\" href=\"https:\/\/media.cooperandhunter.us\/3236\/CH-ES09-230VO-%2B-CH-M09DTUI.pdf\" class=\"hvx-link\" target=\"_blank\"\u003eSubmittal — CH-ES09-230VO + CH-M09DTUI (PDF)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca rel=\"noopener\" href=\"https:\/\/media.cooperandhunter.us\/3240\/CH-HPR09-230VO-%2B-CH-M09DTUI.pdf\" class=\"hvx-link\" target=\"_blank\"\u003eSubmittal — CH-HPR09-230VO + CH-M09DTUI (PDF)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca rel=\"noopener\" href=\"https:\/\/media.cooperandhunter.us\/3778\/Cassette-installation-users_-manual.pdf\" class=\"hvx-link\" target=\"_blank\"\u003eCassette Installation \u0026amp; Users Manual (PDF)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca rel=\"noopener\" href=\"https:\/\/media.cooperandhunter.us\/1170\/SUBMITTAL-DATA-SHEET-SOPHIA-DUCT-CH-M09DTUI.pdf\" class=\"hvx-link\" target=\"_blank\"\u003eSubmittal Data Sheet — Sophia Duct — CH-M09DTUI (PDF)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca rel=\"noopener\" href=\"https:\/\/media.cooperandhunter.us\/1171\/SUBMITTAL-DATA-SHEET-SOPHIA-DUCT-CH-M09DTUI%2BCH-09SHP-230VO.pdf\" class=\"hvx-link\" target=\"_blank\"\u003eSubmittal Data Sheet — CH-M09DTUI + CH-09SHP-230VO (PDF)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca rel=\"noopener\" href=\"https:\/\/media.cooperandhunter.us\/1172\/SUBMITTAL-DATA-SHEET-SOPHIA-DUCT-CH-M09DTUI%2BCH-HYP09SHP230VO.pdf\" class=\"hvx-link\" target=\"_blank\"\u003eSubmittal Data Sheet — CH-M09DTUI + CH-HYP09SHP230VO (PDF)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca rel=\"noopener\" href=\"https:\/\/media.cooperandhunter.us\/1145\/WIRED-CONTROL-FOR-AIR-CONDITIONER-INSTALLATION-MANUAL.pdf\" class=\"hvx-link\" target=\"_blank\"\u003eWired Control Installation Manual (PDF)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca rel=\"noopener\" href=\"https:\/\/media.cooperandhunter.us\/1127\/SOPHIAMULTI-BOOKLET.pdf\" class=\"hvx-link\" target=\"_blank\"\u003eSophia Multi Booklet (PDF)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca rel=\"noopener\" href=\"https:\/\/media.cooperandhunter.us\/1254\/Sophia_Single_Booklet.pdf\" class=\"hvx-link\" target=\"_blank\"\u003eSophia Single Booklet (PDF)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca rel=\"noopener\" href=\"https:\/\/media.cooperandhunter.us\/3848\/SlimDuct-Leaflet-2024.pdf\" class=\"hvx-link\" target=\"_blank\"\u003eSlim Duct Series — Leaflet (2024) (PDF)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca rel=\"noopener\" href=\"https:\/\/media.cooperandhunter.us\/1126\/QUICK-START-GUIDE.pdf\" class=\"hvx-link\" target=\"_blank\"\u003eQuick Start Guide (PDF)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca rel=\"noopener\" href=\"https:\/\/media.cooperandhunter.us\/2272\/Duct-9KHyper-Submittal%C2%A0sheet.pdf\" class=\"hvx-link\" target=\"_blank\"\u003eDuct 9K Hyper — Submittal Sheet (PDF)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca rel=\"noopener\" href=\"https:\/\/media.cooperandhunter.us\/2273\/Duct-9KSubmittal%C2%A0.pdf\" class=\"hvx-link\" target=\"_blank\"\u003eDuct 9K — Submittal (PDF)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca rel=\"noopener\" href=\"https:\/\/media.cooperandhunter.us\/3014\/Installation-manual-Duct-09-24.pdf\" class=\"hvx-link\" target=\"_blank\"\u003eInstallation Manual — Duct 09–24 (PDF)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca rel=\"noopener\" href=\"https:\/\/media.cooperandhunter.us\/3015\/Users-manual-Duct-09-24.pdf\" class=\"hvx-link\" target=\"_blank\"\u003eUser’s Manual — Duct 09–24 (PDF)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca rel=\"noopener\" href=\"https:\/\/media.cooperandhunter.us\/3198\/MultiZone-Combination-HYPER.pdf\" class=\"hvx-link\" target=\"_blank\"\u003eMulti-Zone Combination — HYPER (PDF)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca rel=\"noopener\" href=\"https:\/\/media.cooperandhunter.us\/3199\/MultiZone-Combination-Regular.pdf\" class=\"hvx-link\" target=\"_blank\"\u003eMulti-Zone Combination — Regular (PDF)\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"hvx-desc-card\"\u003e\n\u003ch2 class=\"hvx-section-title\"\u003eImportant\u003c\/h2\u003e\n\u003cp style=\"margin: 0; font-size: 14px;\"\u003eInstall with a licensed HVAC professional. This is a concealed ducted indoor unit intended to be matched with a compatible outdoor system. Confirm electrical requirements (\u003cstrong\u003e208–230V\u003c\/strong\u003e), refrigerant piping sizes (\u003cstrong\u003e1\/4\"\u003c\/strong\u003e liquid, \u003cstrong\u003e3\/8\"\u003c\/strong\u003e gas), and duct layout\/static pressure needs (\u003cstrong\u003eESP 0–0.32\u003c\/strong\u003e). Condensate drainage uses a \u003cstrong\u003e1\"\u003c\/strong\u003e drain connection. Wired controller and wall thermostat setups depend on the controller model and system pairing.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"hvx-desc-card\"\u003e\n\u003ch2 class=\"hvx-section-title\"\u003eFAQs\u003c\/h2\u003e\n\u003cdetails open=\"\" class=\"hvx-faq\"\u003e\n\u003csummary\u003eWhere is this indoor unit typically installed?\u003c\/summary\u003e\n\u003cdiv style=\"margin-top: 8px;\"\u003eIt’s designed to be \u003cstrong\u003econcealed in attics or ceiling crawl spaces\u003c\/strong\u003e, with ducts distributing air to one or more areas.\u003c\/div\u003e\n\u003c\/details\u003e\n\u003cdetails open=\"\" class=\"hvx-faq\"\u003e\n\u003csummary\u003eCan it serve multiple rooms?\u003c\/summary\u003e\n\u003cdiv style=\"margin-top: 8px;\"\u003eYes. Duct runs can be directed into separate areas that are \u003cstrong\u003ecollectively controlled by one thermostat\/controller\u003c\/strong\u003e (system dependent).\u003c\/div\u003e\n\u003c\/details\u003e\n\u003cdetails open=\"\" class=\"hvx-faq\"\u003e\n\u003csummary\u003eWhat line sizes are required?\u003c\/summary\u003e\n\u003cdiv style=\"margin-top: 8px;\"\u003eUse \u003cstrong\u003e1\/4\"\u003c\/strong\u003e liquid and \u003cstrong\u003e3\/8\"\u003c\/strong\u003e gas refrigerant piping.\u003c\/div\u003e\n\u003c\/details\u003e\n\u003cdetails open=\"\" class=\"hvx-faq\"\u003e\n\u003csummary\u003eWhat does ESP mean for this unit?\u003c\/summary\u003e\n\u003cdiv style=\"margin-top: 8px;\"\u003eESP is the unit’s external static pressure capability. This model lists an \u003cstrong\u003eESP range of 0–0.32\u003c\/strong\u003e, which helps support different duct layouts.\u003c\/div\u003e\n\u003c\/details\u003e\n\u003cdetails open=\"\" class=\"hvx-faq\"\u003e\n\u003csummary\u003eWhat are the unit dimensions and noise levels?\u003c\/summary\u003e\n\u003cdiv style=\"margin-top: 8px;\"\u003eDimensions are \u003cstrong\u003e27.56 × 19.92 × 7.87 in\u003c\/strong\u003e (W×H×D). Noise levels are \u003cstrong\u003e33.5\/28.5\/27 dB(A)\u003c\/strong\u003e (H\/M\/L).\u003c\/div\u003e\n\u003c\/details\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e","brand":"Cooper\u0026Hunter","offers":[{"title":"No Installation","offer_id":43086432862251,"sku":"CH-M09DTUI","price":479.0,"currency_code":"USD","in_stock":true},{"title":"16FT","offer_id":43086432895019,"sku":"CH-M09DTUI","price":569.0,"currency_code":"USD","in_stock":true},{"title":"25FT","offer_id":43086432927787,"sku":"CH-M09DTUI","price":705.0,"currency_code":"USD","in_stock":true},{"title":"50FT","offer_id":43086432960555,"sku":"CH-M09DTUI","price":924.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0625\/5647\/1339\/files\/98223e95-7806-4524-871a-57cb6edd9373.png?v=1771367716","url":"https:\/\/hvacsupplies.com\/products\/cooper-hunter-slim-duct-ducted-mini-split-ac-indoor-unit-9-000-btu-r410a","provider":"HVACSupplies.com","version":"1.0","type":"link"}