{"product_id":"cooper-hunter-slim-duct-ducted-mini-split-ac-indoor-unit-24000-btu-r410a","title":"Cooper\u0026Hunter Slim Duct Ducted Mini Split AC Indoor Unit – 24000 BTU | R410A","description":"\u003cstyle\u003e\n  :root{\n    --hvx-golden:#FAA819;\n    --hvx-slate:#262626;\n    --hvx-ivory:#F4F1E6;\n    --hvx-border:#e2e0d5;\n    --hvx-card-bg:#ffffff;\n  }\n\n  .hvx-desc{\n    font-family:\"Articulat CF\",system-ui,-apple-system,BlinkMacSystemFont,\"Segoe UI\",sans-serif;\n    color:var(--hvx-slate);\n    line-height:1.6;\n    background:var(--hvx-ivory);\n    padding:18px 18px 20px;\n    border-radius:16px;\n  }\n\n  .hvx-desc-header{\n    border-radius:14px;\n    padding:14px 16px;\n    background:linear-gradient(120deg,var(--hvx-golden),var(--hvx-slate));\n    color:#fff;\n    margin:0 0 16px;\n    box-shadow:0 10px 24px rgba(0,0,0,.22);\n    display:flex;\n    align-items:flex-start;\n    gap:12px;\n    flex-wrap:wrap;\n  }\n\n  .hvx-header-text{display:flex;flex-direction:column;gap:6px;min-width:260px}\n  .hvx-eyebrow{\n    font-size:11px;\n    letter-spacing:.14em;\n    text-transform:uppercase;\n    opacity:.9;\n  }\n  .hvx-title{\n    margin:0;\n    font-family:\"Anton\",\"Impact\",system-ui,-apple-system,BlinkMacSystemFont,\"Segoe UI\",sans-serif;\n    font-size:22px;\n    line-height:1.15;\n  }\n  .hvx-subtitle{\n    margin:0;\n    font-size:14px;\n    opacity:.95;\n  }\n\n  .hvx-desc-card{\n    border:1px solid var(--hvx-border);\n    border-radius:14px;\n    background:var(--hvx-card-bg);\n    padding:16px 18px 18px;\n    box-shadow:0 4px 12px rgba(0,0,0,.06);\n    margin:14px 0;\n  }\n\n  .hvx-section-title{\n    margin:0 0 10px;\n    font-family:\"Anton\",\"Impact\",system-ui,-apple-system,BlinkMacSystemFont,\"Segoe UI\",sans-serif;\n    font-size:17px;\n    letter-spacing:.08em;\n    text-transform:uppercase;\n    color:var(--hvx-slate);\n    display:inline-flex;\n    align-items:center;\n    gap:8px;\n  }\n  .hvx-section-title::after{\n    content:\"\";\n    flex:1;\n    height:2px;\n    border-radius:999px;\n    background:linear-gradient(90deg,var(--hvx-golden),transparent);\n    opacity:.9;\n  }\n\n  .hvx-cta{display:flex;flex-wrap:wrap;gap:10px;margin:10px 0 0}\n  .hvx-cta a{\n    display:inline-flex;\n    align-items:center;\n    gap:8px;\n    padding:10px 14px;\n    border-radius:12px;\n    border:1px solid var(--hvx-border);\n    background:#fff;\n    text-decoration:none;\n    color:var(--hvx-slate);\n    font-size:14px;\n    font-weight:700;\n  }\n  .hvx-cta a.primary{\n    background:var(--hvx-slate);\n    color:#fff;\n    border-color:transparent;\n  }\n\n  .hvx-badges{display:flex;flex-wrap:wrap;gap:8px;margin:10px 0 0}\n  .hvx-badge{\n    font-size:12px;\n    border:1px solid var(--hvx-border);\n    border-radius:999px;\n    padding:6px 10px;\n    background:#fff;\n    white-space:nowrap;\n  }\n\n  .hvx-kv{\n    display:grid;\n    grid-template-columns:repeat(4,minmax(160px,1fr));\n    gap:10px;\n    margin-top:10px;\n  }\n  .hvx-kv \u003e div{\n    border:1px solid var(--hvx-border);\n    background:#fff;\n    border-radius:12px;\n    padding:10px 12px;\n    text-align:center;\n  }\n  .hvx-kv strong{display:block}\n\n  .hvx-table{\n    width:100%;\n    border-collapse:collapse;\n    min-width:520px;\n    background:#fff;\n    border:1px solid var(--hvx-border);\n    border-radius:12px;\n    overflow:hidden;\n  }\n  .hvx-table th,.hvx-table td{\n    border-bottom:1px solid var(--hvx-border);\n    padding:10px 12px;\n    vertical-align:top;\n    font-size:14px;\n  }\n  .hvx-table th{ text-align:left; font-weight:800; background:#fff; }\n  .hvx-table tr:nth-child(even) td{ background:#fbfaf6; }\n  .hvx-table tr:last-child td{ border-bottom:none; }\n  .hvx-table-wrap{ overflow:auto; border-radius:12px; }\n\n  .hvx-link{color:var(--hvx-slate); text-decoration:underline; text-underline-offset:2px}\n  .hvx-link:hover{opacity:.85}\n\n  details.hvx-faq{\n    border:1px solid var(--hvx-border);\n    background:#fff;\n    border-radius:12px;\n    padding:10px 12px;\n    margin:8px 0;\n  }\n  details.hvx-faq summary{cursor:pointer;font-weight:800;}\n\n  @media(max-width:980px){\n    .hvx-kv{grid-template-columns:repeat(2,minmax(160px,1fr))}\n  }\n  @media(max-width:768px){\n    .hvx-desc{padding:14px 12px 16px;border-radius:12px}\n    .hvx-desc-header{padding:12px;border-radius:12px}\n    .hvx-title{font-size:19px}\n    .hvx-desc-card{padding:14px;margin:10px 0}\n  }\n\u003c\/style\u003e\n\u003cdiv class=\"hvx-desc\"\u003e\n\u003cdiv class=\"hvx-desc-header\"\u003e\n\u003cdiv class=\"hvx-header-text\"\u003e\n\u003cdiv class=\"hvx-eyebrow\"\u003eCooper\u0026amp;Hunter Slim Duct Indoor • 24,000 BTU • 230V • Single\/Multi-Zone\u003c\/div\u003e\n\u003ch1 class=\"hvx-title\"\u003eCooper\u0026amp;Hunter 24,000 BTU Slim Duct Ducted Indoor Unit — CH-24MDT-W\u003c\/h1\u003e\n\u003cp class=\"hvx-subtitle\"\u003eConcealed ducted air handler designed for attics and ceiling crawl spaces, with ducting flexibility and static pressure capability for multi-room distribution.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"hvx-cta\" aria-label=\"Contact options\"\u003e\n\u003ca class=\"primary\" href=\"https:\/\/hvacsupplies.com\/pages\/contact\" rel=\"noopener\" title=\"Contact Us\" target=\"_blank\"\u003eCLICK HERE TO CONTACT US FOR CUSTOM QUOTES AND QUESTIONS\u003c\/a\u003e \u003ca href=\"tel:+18005438933\" title=\"Call Us Now!\"\u003eCLICK TO CALL US 1-800-543-8933 FOR ANY QUESTIONS\u003c\/a\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"hvx-desc-card\"\u003e\n\u003ch2 class=\"hvx-section-title\"\u003eOverview\u003c\/h2\u003e\n\u003cp style=\"margin: 0;\"\u003eCooper\u0026amp;Hunter \u003cstrong\u003eLight Commercial Slim Duct\u003c\/strong\u003e indoor units provide an inconspicuous ducted solution by hiding the air handler in \u003cstrong\u003eattics\u003c\/strong\u003e and \u003cstrong\u003eceiling crawl spaces\u003c\/strong\u003e, reducing the energy losses often associated with traditional central ducted systems. Slim Duct systems also offer installation flexibility—ducts can be directed into separate areas that are \u003cstrong\u003ecollectively controlled by one wall thermostat\u003c\/strong\u003e (controller\/system dependent). \u003cbr\u003e\u003cbr\u003eThe \u003cstrong\u003eCH-24MDT-W\u003c\/strong\u003e is a \u003cstrong\u003e24,000 BTU\u003c\/strong\u003e slim-duct indoor unit designed for \u003cstrong\u003esingle-zone\u003c\/strong\u003e or compatible \u003cstrong\u003emulti-zone\u003c\/strong\u003e applications in \u003cstrong\u003e208–230V\u003c\/strong\u003e systems. With an \u003cstrong\u003eESP range of 0–0.64\u003c\/strong\u003e, it supports a wider variety of duct layouts compared to lower static models. Control options include the included remote and compatibility with wired controllers (120X\/120N).\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"hvx-desc-card\"\u003e\n\u003ch2 class=\"hvx-section-title\"\u003eHighlights\u003c\/h2\u003e\n\u003cdiv class=\"hvx-badges\" role=\"list\"\u003e\n\u003cspan class=\"hvx-badge\" role=\"listitem\"\u003e24,000 BTU (rated)\u003c\/span\u003e \u003cspan class=\"hvx-badge\" role=\"listitem\"\u003eSEER2 19.2\u003c\/span\u003e \u003cspan class=\"hvx-badge\" role=\"listitem\"\u003eEER2 12\u003c\/span\u003e \u003cspan class=\"hvx-badge\" role=\"listitem\"\u003eConcealed Slim Duct\u003c\/span\u003e \u003cspan class=\"hvx-badge\" role=\"listitem\"\u003eESP 0–0.64\u003c\/span\u003e \u003cspan class=\"hvx-badge\" role=\"listitem\"\u003eWired Controller Compatible\u003c\/span\u003e \u003cspan class=\"hvx-badge\" role=\"listitem\"\u003eRG10K Remote Included\u003c\/span\u003e \u003cspan class=\"hvx-badge\" role=\"listitem\"\u003eSingle\/Multi-Zone Compatible\u003c\/span\u003e\n\u003c\/div\u003e\n\u003cul style=\"margin: 12px 0 0; padding-left: 18px;\"\u003e\n\u003cli\u003e\n\u003cstrong\u003eHidden installation:\u003c\/strong\u003e Designed to be concealed in attics and ceiling crawl spaces.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDucting flexibility:\u003c\/strong\u003e Route supply air into multiple areas controlled together by one thermostat\/controller (system dependent).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eStronger static pressure:\u003c\/strong\u003e \u003cstrong\u003eESP 0–0.64\u003c\/strong\u003e supports longer runs and more complex duct layouts.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAir delivery:\u003c\/strong\u003e Multi-speed airflow values: \u003cstrong\u003e775.47 \/ 693.06 \/ 434.88\u003c\/strong\u003e.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eControls:\u003c\/strong\u003e Included RG10K remote and wired controller compatibility (120X\/120N).\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cdiv class=\"hvx-kv\" role=\"list\" aria-label=\"At-a-glance\"\u003e\n\u003cdiv role=\"listitem\"\u003e\n\u003cstrong\u003eModel\u003c\/strong\u003eCH-24MDT-W\u003c\/div\u003e\n\u003cdiv role=\"listitem\"\u003e\n\u003cstrong\u003eSystem Type\u003c\/strong\u003eSingle\/Multi-Zone\u003c\/div\u003e\n\u003cdiv role=\"listitem\"\u003e\n\u003cstrong\u003eLine Set\u003c\/strong\u003e3\/8\" (liq) \/ 5\/8\" (gas)\u003c\/div\u003e\n\u003cdiv role=\"listitem\"\u003e\n\u003cstrong\u003eSound (H\/M\/L)\u003c\/strong\u003e44\/41\/37 dB(A)\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"hvx-desc-card\"\u003e\n\u003ch2 class=\"hvx-section-title\"\u003eWhat's Included\u003c\/h2\u003e\n\u003cul style=\"padding-left: 18px; margin: 8px 0;\"\u003e\n\u003cli\u003eSlim duct indoor unit: \u003cstrong\u003eCH-24MDT-W\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003eRemote control: \u003cstrong\u003eRG10K-exclusive\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"hvx-desc-card\"\u003e\n\u003ch2 class=\"hvx-section-title\"\u003eIndoor Specs\u003c\/h2\u003e\n\u003cdiv class=\"hvx-table-wrap\"\u003e\n\u003ctable class=\"hvx-table\" aria-label=\"Indoor unit specifications\"\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eSpec\u003c\/th\u003e\n\u003cth\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCH-24MDT-W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSystem Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSingle\/Multi-zone unit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBTU Rated\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e24,000\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower Source\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e208–230V, 1Ph, 60Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eVoltage Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e187–253 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSEER2 \/ EER2\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e19.2 \/ 12\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMinimum Circuit Ampacity (MCA)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMax Fuse\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e15 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDehumidification\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4.18 pints\/day\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eController\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eRG10K-exclusive remote \u0026amp; 120X or 120N wire controller\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRefrigerant Piping (Liquid \/ Gas)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3\/8\" \/ 5\/8\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIndoor Noise (H\/M\/L)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e44 \/ 41 \/ 37 dB(A)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIndoor Air Flow\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e775.47 \/ 693.06 \/ 434.88\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eESP Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0–0.64\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eUnit Dimensions (W×H×D)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e43.31 × 30.47 × 9.80 in\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eUnit Net \/ Gross Weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e90.39 \/ 105.82 lb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePacking Dimensions (W×D×H)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e51.38 × 31.69 × 12.40\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDrain Pipe Diameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperation Range (Cooling)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e62–90 °F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperation Range (Heating)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e32–86 °F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"hvx-desc-card\"\u003e\n\u003ch2 class=\"hvx-section-title\"\u003eVideos\u003c\/h2\u003e\n\u003cdiv style=\"margin: 8px 0 0;\"\u003e\n\u003cdiv style=\"font-weight: 800; margin: 10px 0 6px;\"\u003eMini-split installation videos\u003c\/div\u003e\n\u003cul style=\"padding-left: 18px; margin: 0;\"\u003e\n\u003cli\u003e\u003ca class=\"hvx-link\" href=\"https:\/\/youtu.be\/ieOdKq8yBKY\" rel=\"noopener\" target=\"_blank\"\u003eCooper\u0026amp;Hunter Mini Split Slim Duct Installation\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"hvx-desc-card\"\u003e\n\u003ch2 class=\"hvx-section-title\"\u003eDocuments \u0026amp; Downloads\u003c\/h2\u003e\n\u003cul style=\"padding-left: 18px; margin: 8px 0;\"\u003e\n\u003cli\u003e\u003ca class=\"hvx-link\" href=\"https:\/\/media.cooperandhunter.us\/3869\/CH-24MDT-W.pdf\" rel=\"noopener\" target=\"_blank\"\u003eSubmittal — CH-24MDT-W (PDF)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca class=\"hvx-link\" href=\"https:\/\/media.cooperandhunter.us\/3870\/CH-ES24-230VO-%2B-CH-24MDT-W.pdf\" rel=\"noopener\" target=\"_blank\"\u003eSubmittal — CH-ES24-230VO + CH-24MDT-W (PDF)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca class=\"hvx-link\" href=\"https:\/\/media.cooperandhunter.us\/2279\/Duct-24K-Submittal%C2%A0.pdf\" rel=\"noopener\" target=\"_blank\"\u003eDuct 24K — Submittal (PDF)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca class=\"hvx-link\" href=\"https:\/\/media.cooperandhunter.us\/3014\/Installation-manual-Duct-09-24.pdf\" rel=\"noopener\" target=\"_blank\"\u003eInstallation Manual — Duct 09–24 (PDF)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca class=\"hvx-link\" href=\"https:\/\/media.cooperandhunter.us\/3198\/MultiZone-Combination-HYPER.pdf\" rel=\"noopener\" target=\"_blank\"\u003eMulti-Zone Combination — HYPER (PDF)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca class=\"hvx-link\" href=\"https:\/\/media.cooperandhunter.us\/3199\/MultiZone-Combination-Regular.pdf\" rel=\"noopener\" target=\"_blank\"\u003eMulti-Zone Combination — Regular (PDF)\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"hvx-desc-card\"\u003e\n\u003ch2 class=\"hvx-section-title\"\u003eImportant\u003c\/h2\u003e\n\u003cp style=\"margin: 0; font-size: 14px;\"\u003eInstall with a licensed HVAC professional. This is a concealed ducted indoor unit intended to be matched with a compatible outdoor system. Confirm electrical requirements (\u003cstrong\u003e208–230V\u003c\/strong\u003e), refrigerant piping sizes (\u003cstrong\u003e3\/8\"\u003c\/strong\u003e liquid, \u003cstrong\u003e5\/8\"\u003c\/strong\u003e gas), and duct design\/static pressure needs (\u003cstrong\u003eESP 0–0.64\u003c\/strong\u003e). Condensate drainage uses a \u003cstrong\u003e1\"\u003c\/strong\u003e drain connection. Wired controller and wall thermostat setups depend on the controller model and system pairing.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"hvx-desc-card\"\u003e\n\u003ch2 class=\"hvx-section-title\"\u003eFAQs\u003c\/h2\u003e\n\u003cdetails class=\"hvx-faq\" open=\"\"\u003e\n\u003csummary\u003eWhere is this indoor unit typically installed?\u003c\/summary\u003e\n\u003cdiv style=\"margin-top: 8px;\"\u003eIt’s designed to be \u003cstrong\u003econcealed in attics or ceiling crawl spaces\u003c\/strong\u003e, with ducts distributing air to the conditioned areas.\u003c\/div\u003e\n\u003c\/details\u003e\n\u003cdetails class=\"hvx-faq\" open=\"\"\u003e\n\u003csummary\u003eCan it serve multiple rooms?\u003c\/summary\u003e\n\u003cdiv style=\"margin-top: 8px;\"\u003eYes. Duct runs can be directed into separate areas that are \u003cstrong\u003ecollectively controlled by one wall thermostat\/controller\u003c\/strong\u003e (system dependent).\u003c\/div\u003e\n\u003c\/details\u003e\n\u003cdetails class=\"hvx-faq\" open=\"\"\u003e\n\u003csummary\u003eWhat line sizes are required?\u003c\/summary\u003e\n\u003cdiv style=\"margin-top: 8px;\"\u003eUse \u003cstrong\u003e3\/8\"\u003c\/strong\u003e liquid and \u003cstrong\u003e5\/8\"\u003c\/strong\u003e gas refrigerant piping.\u003c\/div\u003e\n\u003c\/details\u003e\n\u003cdetails class=\"hvx-faq\" open=\"\"\u003e\n\u003csummary\u003eWhat does ESP mean for this unit?\u003c\/summary\u003e\n\u003cdiv style=\"margin-top: 8px;\"\u003eESP is the unit’s external static pressure capability. This model lists an \u003cstrong\u003eESP range of 0–0.64\u003c\/strong\u003e to support more ducting resistance and layout flexibility.\u003c\/div\u003e\n\u003c\/details\u003e\n\u003cdetails class=\"hvx-faq\" open=\"\"\u003e\n\u003csummary\u003eWhat are the unit dimensions and noise levels?\u003c\/summary\u003e\n\u003cdiv style=\"margin-top: 8px;\"\u003eDimensions are \u003cstrong\u003e43.31 × 30.47 × 9.80 in\u003c\/strong\u003e (W×H×D). Noise levels are \u003cstrong\u003e44\/41\/37 dB(A)\u003c\/strong\u003e (H\/M\/L).\u003c\/div\u003e\n\u003c\/details\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e","brand":"Cooper\u0026Hunter","offers":[{"title":"No Installation","offer_id":43086434762795,"sku":"CH-24MDT-W","price":818.0,"currency_code":"USD","in_stock":false},{"title":"16FT","offer_id":43086434795563,"sku":"CH-24MDT-W","price":1032.0,"currency_code":"USD","in_stock":false},{"title":"25FT","offer_id":43086434828331,"sku":"CH-24MDT-W","price":1161.0,"currency_code":"USD","in_stock":false},{"title":"50FT","offer_id":43086434861099,"sku":"CH-24MDT-W","price":1466.0,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0625\/5647\/1339\/files\/98223e95-7806-4524-871a-57cb6edd9373.png?v=1771367716","url":"https:\/\/hvacsupplies.com\/products\/cooper-hunter-slim-duct-ducted-mini-split-ac-indoor-unit-24000-btu-r410a","provider":"HVACSupplies.com","version":"1.0","type":"link"}