{"product_id":"cooper-hunter-hyper-multi-zone-r454b-outdoor-condenser-28-000-btu-2-33-ton","title":"Cooper\u0026Hunter Hyper Multi-Zone R454B Outdoor Condenser 28,000 BTU (2.33 Ton)","description":"\u003cstyle\u003e\n  :root{\n    --hvx-golden:#FAA819;\n    --hvx-slate:#262626;\n    --hvx-ivory:#F4F1E6;\n    --hvx-border:#e2e0d5;\n    --hvx-card-bg:#ffffff;\n  }\n\n  .hvx-desc{\n    font-family:\"Articulat CF\",system-ui,-apple-system,BlinkMacSystemFont,\"Segoe UI\",sans-serif;\n    color:var(--hvx-slate);\n    line-height:1.6;\n    background:var(--hvx-ivory);\n    padding:18px 18px 20px;\n    border-radius:16px;\n  }\n\n  .hvx-desc-header{\n    border-radius:14px;\n    padding:14px 16px;\n    background:linear-gradient(120deg,var(--hvx-golden),var(--hvx-slate));\n    color:#fff;\n    margin:0 0 16px;\n    box-shadow:0 10px 24px rgba(0,0,0,.22);\n    display:flex;\n    align-items:flex-start;\n    gap:12px;\n    flex-wrap:wrap;\n  }\n\n  .hvx-header-text{display:flex;flex-direction:column;gap:4px;min-width:260px}\n  .hvx-eyebrow{\n    font-size:11px;\n    letter-spacing:.14em;\n    text-transform:uppercase;\n    opacity:.9;\n  }\n  .hvx-title{\n    margin:0;\n    font-family:\"Anton\",\"Impact\",system-ui,-apple-system,BlinkMacSystemFont,\"Segoe UI\",sans-serif;\n    font-size:22px;\n    line-height:1.15;\n  }\n\n  .hvx-desc-card{\n    border:1px solid var(--hvx-border);\n    border-radius:14px;\n    background:var(--hvx-card-bg);\n    padding:16px 18px 18px;\n    box-shadow:0 4px 12px rgba(0,0,0,.06);\n    margin:14px 0;\n  }\n\n  .hvx-section-title{\n    margin:0 0 10px;\n    font-family:\"Anton\",\"Impact\",system-ui,-apple-system,BlinkMacSystemFont,\"Segoe UI\",sans-serif;\n    font-size:17px;\n    letter-spacing:.08em;\n    text-transform:uppercase;\n    color:var(--hvx-slate);\n    display:inline-flex;\n    align-items:center;\n    gap:8px;\n  }\n  .hvx-section-title::after{\n    content:\"\";\n    flex:1;\n    height:2px;\n    border-radius:999px;\n    background:linear-gradient(90deg,var(--hvx-golden),transparent);\n    opacity:.9;\n  }\n\n  .hvx-cta{display:flex;flex-wrap:wrap;gap:10px;margin:10px 0 0}\n  .hvx-cta a{\n    display:inline-flex;\n    align-items:center;\n    gap:8px;\n    padding:10px 14px;\n    border-radius:12px;\n    border:1px solid var(--hvx-border);\n    background:#fff;\n    text-decoration:none;\n    color:var(--hvx-slate);\n    font-size:14px;\n    font-weight:700;\n  }\n  .hvx-cta a.primary{\n    background:var(--hvx-slate);\n    color:#fff;\n    border-color:transparent;\n  }\n\n  .hvx-badges{display:flex;flex-wrap:wrap;gap:8px;margin:10px 0 0}\n  .hvx-badge{\n    font-size:12px;\n    border:1px solid var(--hvx-border);\n    border-radius:999px;\n    padding:6px 10px;\n    background:#fff;\n    white-space:nowrap;\n  }\n\n  .hvx-kv{\n    display:grid;\n    grid-template-columns:repeat(4,minmax(160px,1fr));\n    gap:10px;\n    margin-top:10px;\n  }\n  .hvx-kv \u003e div{\n    border:1px solid var(--hvx-border);\n    background:#fff;\n    border-radius:12px;\n    padding:10px 12px;\n    text-align:center;\n  }\n  .hvx-kv strong{display:block}\n\n  .hvx-table{\n    width:100%;\n    border-collapse:collapse;\n    min-width:520px;\n    background:#fff;\n    border:1px solid var(--hvx-border);\n    border-radius:12px;\n    overflow:hidden;\n  }\n  .hvx-table th,.hvx-table td{\n    border-bottom:1px solid var(--hvx-border);\n    padding:10px 12px;\n    vertical-align:top;\n    font-size:14px;\n  }\n  .hvx-table th{ text-align:left; font-weight:800; background:#fff; }\n  .hvx-table tr:nth-child(odd) td{ background:#fff; }\n  .hvx-table tr:nth-child(even) td{ background:#fbfaf6; }\n  .hvx-table tr:last-child td{ border-bottom:none; }\n  .hvx-table-wrap{ overflow:auto; border-radius:12px; }\n\n  .hvx-note{\n    font-size:12px;\n    color:#555;\n    margin:10px 0 0;\n  }\n\n  details.hvx-faq{\n    border:1px solid var(--hvx-border);\n    background:#fff;\n    border-radius:12px;\n    padding:10px 12px;\n    margin:8px 0;\n  }\n  details.hvx-faq summary{\n    cursor:pointer;\n    font-weight:800;\n  }\n\n  @media(max-width:980px){\n    .hvx-kv{grid-template-columns:repeat(2,minmax(160px,1fr))}\n  }\n  @media(max-width:768px){\n    .hvx-desc{padding:14px 12px 16px;border-radius:12px}\n    .hvx-desc-header{padding:12px;border-radius:12px}\n    .hvx-title{font-size:19px}\n    .hvx-desc-card{padding:14px;margin:10px 0}\n  }\n\u003c\/style\u003e\n\u003cdiv class=\"hvx-desc\"\u003e\n\u003cdiv class=\"hvx-desc-header\"\u003e\n\u003cdiv class=\"hvx-header-text\"\u003e\n\u003cdiv class=\"hvx-eyebrow\"\u003eCooper\u0026amp;Hunter Hyper Heat Multi-Zone Outdoor • R454B • Up to 4 Zones\u003c\/div\u003e\n\u003ch1 class=\"hvx-title\"\u003eCooper\u0026amp;Hunter Hyper Heat Multi-Zone Outdoor — 28,000 BTU, R454B — CH-RVHP28M-230VO\u003c\/h1\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"hvx-cta\" aria-label=\"Contact options\"\u003e\n\u003ca class=\"primary\" href=\"https:\/\/hvacsupplies.com\/pages\/contact\" rel=\"noopener\" title=\"Contact Us\" target=\"_blank\"\u003e CLICK HERE TO CONTACT US FOR CUSTOM QUOTES AND QUESTIONS \u003c\/a\u003e \u003ca href=\"tel:+18005438933\" title=\"Call Us Now!\"\u003e CLICK TO CALL US 1-800-543-8933 FOR ANY QUESTIONS \u003c\/a\u003e \u003cbr\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"hvx-desc-card\"\u003e\n\u003ch2 class=\"hvx-section-title\"\u003eOverview\u003c\/h2\u003e\n\u003cp style=\"margin: 0;\"\u003eCooper\u0026amp;Hunter’s 28K BTU Hyper Heat Multi-Zone outdoor unit delivers high-performance comfort for residential spaces with up to four zones of independent room-by-room control. Hyper Heating technology provides dependable operation in extreme cold, with heating rated down to −22 °F. Inverter technology dynamically adjusts compressor output to match zone demand for efficient, steady performance. With up to 23 SEER2 efficiency and R454B refrigerant (lower GWP vs. many conventional options), it’s built for modern, eco-conscious multi-zone installations.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"hvx-desc-card\"\u003e\n\u003ch2 class=\"hvx-section-title\"\u003eHighlights\u003c\/h2\u003e\n\u003cdiv class=\"hvx-badges\" role=\"list\"\u003e\n\u003cspan class=\"hvx-badge\" role=\"listitem\"\u003eUp to 4 zones\u003c\/span\u003e \u003cspan class=\"hvx-badge\" role=\"listitem\"\u003eSEER2 23 · EER2 12.5\u003c\/span\u003e \u003cspan class=\"hvx-badge\" role=\"listitem\"\u003eHSPF 10.5 (Region IV) · 8.5 (Region V)\u003c\/span\u003e \u003cspan class=\"hvx-badge\" role=\"listitem\"\u003eCOP 3.8 @ 47 °F\u003c\/span\u003e \u003cspan class=\"hvx-badge\" role=\"listitem\"\u003eHyper Heat to −22 °F\u003c\/span\u003e \u003cspan class=\"hvx-badge\" role=\"listitem\"\u003eR454B\u003c\/span\u003e \u003cspan class=\"hvx-badge\" role=\"listitem\"\u003e208–230V 1Ph\u003c\/span\u003e \u003cspan class=\"hvx-badge\" role=\"listitem\"\u003eMax total piping 262.4 ft\u003c\/span\u003e\n\u003c\/div\u003e\n\u003cul style=\"margin: 12px 0 0; padding-left: 18px;\"\u003e\n\u003cli\u003e\n\u003cstrong\u003eCold-climate heating:\u003c\/strong\u003e heating operation rated down to −22 °F.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMulti-zone control:\u003c\/strong\u003e supports up to four independent zones with compatible indoor units.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEnergy smart:\u003c\/strong\u003e inverter-driven operation with up to 23 SEER2 efficiency.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEco-forward refrigerant:\u003c\/strong\u003e R454B helps reduce environmental impact.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInstaller-friendly:\u003c\/strong\u003e generous piping allowances for flexible layouts (within design limits).\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cdiv class=\"hvx-kv\" role=\"list\" aria-label=\"At-a-glance\"\u003e\n\u003cdiv role=\"listitem\"\u003e\n\u003cstrong\u003eModel\u003c\/strong\u003eCH-RVHP28M-230VO\u003c\/div\u003e\n\u003cdiv role=\"listitem\"\u003e\n\u003cstrong\u003eZones\u003c\/strong\u003eUp to 4\u003c\/div\u003e\n\u003cdiv role=\"listitem\"\u003e\n\u003cstrong\u003eOutdoor Sound\u003c\/strong\u003e61 dB(A)\u003c\/div\u003e\n\u003cdiv role=\"listitem\"\u003e\n\u003cstrong\u003eLines\u003c\/strong\u003e4× 1\/4″ liquid · (3× 3\/8″ + 1× 1\/2″) gas\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"hvx-desc-card\"\u003e\n\u003ch2 class=\"hvx-section-title\"\u003eWhat's Included\u003c\/h2\u003e\n\u003cul style=\"padding-left: 18px; margin: 8px 0;\"\u003e\n\u003cli\u003eOutdoor unit CH-RVHP28M-230VO\u003c\/li\u003e\n\u003cli\u003eOwner \/ installation documentation\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp class=\"hvx-note\"\u003ePair only with compatible Cooper\u0026amp;Hunter multi-zone indoor units. Confirm zone combinations, piping, and length limits before installation.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"hvx-desc-card\"\u003e\n\u003ch2 class=\"hvx-section-title\"\u003eIndoor Specs\u003c\/h2\u003e\n\u003cdiv class=\"hvx-table-wrap\"\u003e\n\u003ctable class=\"hvx-table\" aria-label=\"Indoor unit compatibility\"\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eSpec\u003c\/th\u003e\n\u003cth\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSystem type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eHyper Heat multi-zone outdoor unit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eZones supported\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eUp to 4 independent zones (depends on indoor unit selection)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRefrigerant piping\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4 circuits: 4× 1\/4″ liquid · gas connections are 3× 3\/8″ + 1× 1\/2″\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMax total pipe length\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e262.4 ft\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMax length per indoor unit\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e114.8 ft\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMax height difference (IDU↔ODU)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e49.2 ft\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMax height difference (between indoor units)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e33 ft\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCombination guidance\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eUse the provided Multi-Zone Combination PDF to confirm valid indoor mixes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003cp class=\"hvx-note\"\u003eIndoor-unit capacities, controls, and features depend on the specific indoor models selected for each zone.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"hvx-desc-card\"\u003e\n\u003ch2 class=\"hvx-section-title\"\u003eOutdoor Specs\u003c\/h2\u003e\n\u003cdiv class=\"hvx-table-wrap\"\u003e\n\u003ctable class=\"hvx-table\" aria-label=\"Outdoor unit specifications\"\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eSpec\u003c\/th\u003e\n\u003cth\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCH-RVHP28M-230VO\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e208\/230 V, 1-Phase, 60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eVoltage range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e187–253 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCooling capacity (range)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e7,200–37,000 BTU\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCooling current (rated)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e9.5 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSEER2 \/ EER2\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e23 \/ 12.5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eHeating capacity @ 47 °F (range)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e8,400–36,000 BTU\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eHeating current @ 47 °F (rated)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e9.1 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCOP @ 47 °F\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3.8 W\/W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eHSPF (Region IV \/ V)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e10.5 \/ 8.5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eHeating capacity @ 5 °F (rated)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e27,000 BTU\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMCA \/ Max fuse\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e30 A \/ 35 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOutdoor airflow (max)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2,148.4 CFM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOutdoor sound\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e61 dB(A)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eUnit size (W×D×H)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e37.24 × 16.14 × 31.89 in\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePacking size (W×D×H)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e42.91 × 19.68 × 34.84 in\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNet \/ Gross weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e168.43 \/ 179.67 lb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRefrigerant \/ Charge\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eR454B \/ 120.63 oz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFactory precharge\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e100 ft\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAdditional refrigerant charge\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.16 oz\/ft\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDesign pressure\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e550 \/ 340 PSIG\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAmbient range (cool \/ heat)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e−22–122 °F \/ −22–75 °F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eLine sizes\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eLiquid: 4× 1\/4″ · Gas: 3× 3\/8″ + 1× 1\/2″\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMax piping (total \/ per indoor)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e262.4 ft \/ 114.8 ft\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMax height difference\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIDU↔ODU: 49.2 ft · Between IDUs: 33 ft\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"hvx-desc-card\"\u003e\n\u003ch2 class=\"hvx-section-title\"\u003eDocuments \u0026amp; Downloads\u003c\/h2\u003e\n\u003cul style=\"padding-left: 18px; margin: 8px 0;\"\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/media.cooperandhunter.us\/4809\/CH-RVHP28M-230VO.pdf\" rel=\"noopener\" target=\"_blank\"\u003eCH-RVHP28M-230VO Submittal (PDF)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/media.cooperandhunter.us\/4433\/Installation-manual.pdf\" rel=\"noopener\" target=\"_blank\"\u003eInstallation Manual (PDF)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/media.cooperandhunter.us\/4811\/RVHP-Installation-manual-Multi-Zone-Units_compressed.pdf\" rel=\"noopener\" target=\"_blank\"\u003eRVHP Multi-Zone Units Installation Manual (PDF)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/media.cooperandhunter.us\/3198\/MultiZone-Combination-HYPER.pdf\" rel=\"noopener\" target=\"_blank\"\u003eMulti-Zone Combination — HYPER (PDF)\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp class=\"hvx-note\"\u003eAHRI certification numbers (reference): Ducted 210799632 · Non-Ducted 210799631 · Mixed 210799633.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"hvx-desc-card\"\u003e\n\u003ch2 class=\"hvx-section-title\"\u003eImportant\u003c\/h2\u003e\n\u003cp class=\"hvx-note\" style=\"font-size: 14px; color: var(--hvx-slate); margin: 0;\"\u003eInstall by a licensed HVAC professional. Confirm zone combinations, electrical requirements (187–253 V), MCA\/max-fuse, line sizes (including the 1\/2″ gas circuit), total\/branch piping limits, and ambient operating ranges (down to −22 °F) before commissioning.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"hvx-desc-card\"\u003e\n\u003ch2 class=\"hvx-section-title\"\u003eFAQs\u003c\/h2\u003e\n\u003cdetails class=\"hvx-faq\" open=\"\"\u003e\n\u003csummary\u003eHow many zones can this support?\u003c\/summary\u003e\n\u003cdiv style=\"margin-top: 8px;\"\u003eUp to four independent zones with compatible Cooper\u0026amp;Hunter multi-zone indoor units.\u003c\/div\u003e\n\u003c\/details\u003e\n\u003cdetails class=\"hvx-faq\" open=\"\"\u003e\n\u003csummary\u003eHow cold can it heat in Hyper Heat mode?\u003c\/summary\u003e\n\u003cdiv style=\"margin-top: 8px;\"\u003eHeating operation is rated down to −22 °F.\u003c\/div\u003e\n\u003c\/details\u003e\n\u003cdetails class=\"hvx-faq\" open=\"\"\u003e\n\u003csummary\u003eWhat line sizes are required?\u003c\/summary\u003e\n\u003cdiv style=\"margin-top: 8px;\"\u003eFour circuits total: 4× 1\/4″ liquid and gas connections of 3× 3\/8″ plus 1× 1\/2″.\u003c\/div\u003e\n\u003c\/details\u003e\n\u003cdetails class=\"hvx-faq\" open=\"\"\u003e\n\u003csummary\u003eWhat are the power requirements?\u003c\/summary\u003e\n\u003cdiv style=\"margin-top: 8px;\"\u003e208\/230 V, single-phase, 60 Hz. Voltage range 187–253 V. MCA 30 A. Max fuse 35 A.\u003c\/div\u003e\n\u003c\/details\u003e\n\u003cdetails class=\"hvx-faq\" open=\"\"\u003e\n\u003csummary\u003eWhat are the piping limits?\u003c\/summary\u003e\n\u003cdiv style=\"margin-top: 8px;\"\u003eUp to 262.4 ft total piping, and up to 114.8 ft for a single indoor unit run, within system design limits.\u003c\/div\u003e\n\u003c\/details\u003e\n\u003cdetails class=\"hvx-faq\" open=\"\"\u003e\n\u003csummary\u003eWhat refrigerant does it use?\u003c\/summary\u003e\n\u003cdiv style=\"margin-top: 8px;\"\u003eR454B (factory charge: 120.63 oz; precharge: 100 ft).\u003c\/div\u003e\n\u003c\/details\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e","brand":"Cooper\u0026Hunter","offers":[{"title":"Default Title","offer_id":42697727639595,"sku":"CH-RVHP28M-230VO","price":2867.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0625\/5647\/1339\/files\/19000BTUHYPER_1.png?v=1769188233","url":"https:\/\/hvacsupplies.com\/products\/cooper-hunter-hyper-multi-zone-r454b-outdoor-condenser-28-000-btu-2-33-ton","provider":"HVACSupplies.com","version":"1.0","type":"link"}