{"product_id":"cooper-hunter-6-000-btu-hyper-single-zone-one-way-cassette-minisplit-heat-pump-system-r454b-230v","title":"Cooper\u0026Hunter 6,000 BTU Hyper Single Zone One-Way Cassette Minisplit Heat Pump System R454B 230V","description":"\u003cstyle\u003e\n    :root{--hvx-golden:#FAA819;--hvx-slate:#262626;--hvx-ivory:#F4F1E6;--hvx-border:#e2e0d5;--hvx-card-bg:#ffffff;}\n    .hvx-desc{background:var(--hvx-ivory);padding:18px;border-radius:18px;font-family:\"Articulat CF\",system-ui,-apple-system,Segoe UI,Roboto,Arial,sans-serif;color:#111;}\n    .hvx-desc-header{background:linear-gradient(120deg,var(--hvx-golden),var(--hvx-slate));border-radius:16px;padding:16px 16px 14px;color:#fff;margin-bottom:14px;}\n    .hvx-eyebrow{font-size:12px;letter-spacing:.12em;text-transform:uppercase;opacity:.9;margin:0 0 6px;}\n    .hvx-title{font-family:\"Anton\",Impact,Haettenschweiler,\"Arial Narrow Bold\",sans-serif;font-size:26px;line-height:1.05;margin:0;}\n    .hvx-desc-card{background:var(--hvx-card-bg);border:1px solid var(--hvx-border);border-radius:16px;padding:14px;margin:12px 0;box-shadow:0 10px 18px rgba(0,0,0,.06);}\n    .hvx-section-title{margin:0 0 10px;font-size:13px;letter-spacing:.12em;text-transform:uppercase;display:inline-block;padding-bottom:6px;position:relative;}\n    .hvx-section-title:after{content:\"\";position:absolute;left:0;bottom:0;height:3px;width:100%;border-radius:99px;background:linear-gradient(90deg,var(--hvx-golden),var(--hvx-slate));}\n    .hvx-badges{display:flex;flex-wrap:wrap;gap:8px;margin:6px 0 10px;}\n    .hvx-badge{display:inline-flex;align-items:center;gap:6px;padding:6px 10px;border-radius:999px;border:1px solid var(--hvx-border);background:#fff;font-size:12px;font-weight:600;}\n    .hvx-grid{display:grid;grid-template-columns:repeat(3,minmax(0,1fr));gap:10px;}\n    .hvx-kv{border:1px solid var(--hvx-border);border-radius:14px;padding:10px;background:#fff;}\n    .hvx-k{font-size:12px;letter-spacing:.08em;text-transform:uppercase;color:#333;margin:0 0 6px;}\n    .hvx-v{font-size:14px;font-weight:700;margin:0;}\n    .hvx-table-wrap{overflow:auto;border-radius:14px;border:1px solid var(--hvx-border);background:#fff;}\n    table.hvx-table{width:100%;border-collapse:collapse;min-width:520px;}\n    .hvx-table th,.hvx-table td{padding:10px 12px;border-bottom:1px solid var(--hvx-border);vertical-align:top;font-size:14px;}\n    .hvx-table th{background:rgba(250,168,25,.12);text-align:left;font-size:12px;letter-spacing:.1em;text-transform:uppercase;}\n    .hvx-table tr:last-child td{border-bottom:none;}\n    .hvx-link{color:#111;text-decoration:none;border-bottom:2px solid rgba(250,168,25,.7);}\n    .hvx-link:hover{border-bottom-color:#111;}\n    .hvx-faq details{border:1px solid var(--hvx-border);border-radius:14px;background:#fff;padding:10px 12px;margin:10px 0;}\n    .hvx-faq summary{cursor:pointer;font-weight:800;}\n    .hvx-muted{color:#333;margin:6px 0 0;}\n    @media (max-width:720px){.hvx-grid{grid-template-columns:1fr;}.hvx-title{font-size:24px;}}\n  \u003c\/style\u003e\n\u003cdiv class=\"hvx-desc\"\u003e\n\u003cdiv class=\"hvx-desc-header\"\u003e\n\u003cp class=\"hvx-eyebrow\"\u003eSingle Zone • One-Way Ceiling Cassette • 6K–12K Configurable • R454B • 208–230V\u003c\/p\u003e\n\u003ch2 class=\"hvx-title\"\u003eCooper\u0026amp;Hunter 6,000 BTU Hyper Single Zone One-Way Cassette Minisplit Heat Pump System R454B 230V\u003c\/h2\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"hvx-desc-card\"\u003e\n\u003ch3 class=\"hvx-section-title\"\u003eOverview\u003c\/h3\u003e\n\u003cp class=\"hvx-muted\"\u003eCompact, between-joist one-way ceiling cassette built for flexible installs in smaller spaces. The CH-RSH06-12MCT1W supports capacity selection (6K \/ 9K \/ 12K) via ENC1 dip switch and includes a built-in condensate pump. Pairing with the Hyper outdoor unit adds strong low-ambient performance for heating and cooling.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"hvx-desc-card\"\u003e\n\u003ch3 class=\"hvx-section-title\"\u003eHighlights\u003c\/h3\u003e\n\u003cdiv class=\"hvx-badges\"\u003e\n\u003cspan class=\"hvx-badge\"\u003eR454B Refrigerant\u003c\/span\u003e \u003cspan class=\"hvx-badge\"\u003eBetween-Joist Fit\u003c\/span\u003e \u003cspan class=\"hvx-badge\"\u003e6K \/ 9K \/ 12K Selectable\u003c\/span\u003e \u003cspan class=\"hvx-badge\"\u003eBuilt-In Pump\u003c\/span\u003e \u003cspan class=\"hvx-badge\"\u003eHumidity Sensor\u003c\/span\u003e \u003cspan class=\"hvx-badge\"\u003eRefrigerant Sensor\u003c\/span\u003e \u003cspan class=\"hvx-badge\"\u003eHyper Heating Outdoor\u003c\/span\u003e\n\u003c\/div\u003e\n\u003cul class=\"hvx-muted\" style=\"margin: 0 0 10px; padding-left: 18px;\"\u003e\n\u003cli\u003eDesigned to fit cleanly between structural ceiling beams for flexible placement.\u003c\/li\u003e\n\u003cli\u003eCapacity can be set to 6K, 9K, or 12K via ENC1 dip switch for right-sized comfort.\u003c\/li\u003e\n\u003cli\u003eBuilt-in condensate pump helps simplify drainage routing.\u003c\/li\u003e\n\u003cli\u003eHumidity and refrigerant sensors support stable indoor conditions and system monitoring.\u003c\/li\u003e\n\u003cli\u003eHyper outdoor unit supports operation down to -22°F ambient in heating.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cdiv class=\"hvx-grid\"\u003e\n\u003cdiv class=\"hvx-kv\"\u003e\n\u003cp class=\"hvx-k\"\u003eIndoor Model\u003c\/p\u003e\n\u003cp class=\"hvx-v\"\u003e\u003ca class=\"hvx-link\" href=\"https:\/\/hvacsupplies.com\/search?options%5Bprefix%5D=last\u0026amp;q=CH-RSH06-12MCT1W\"\u003eCH-RSH06-12MCT1W\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"hvx-kv\"\u003e\n\u003cp class=\"hvx-k\"\u003eOutdoor Model\u003c\/p\u003e\n\u003cp class=\"hvx-v\"\u003e\u003ca class=\"hvx-link\" href=\"https:\/\/hvacsupplies.com\/search?options%5Bprefix%5D=last\u0026amp;q=CH-RHP06F9-230VO\"\u003eCH-RHP06F9-230VO\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"hvx-kv\"\u003e\n\u003cp class=\"hvx-k\"\u003eLine Set Size\u003c\/p\u003e\n\u003cp class=\"hvx-v\"\u003e1\/4\" Liquid • 3\/8\" Gas\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"hvx-kv\"\u003e\n\u003cp class=\"hvx-k\"\u003eSelectable Capacity\u003c\/p\u003e\n\u003cp class=\"hvx-v\"\u003e6K \/ 9K \/ 12K (ENC1)\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"hvx-kv\"\u003e\n\u003cp class=\"hvx-k\"\u003eMax Line Length\u003c\/p\u003e\n\u003cp class=\"hvx-v\"\u003e82 ft\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"hvx-kv\"\u003e\n\u003cp class=\"hvx-k\"\u003eLow-Ambient Heating\u003c\/p\u003e\n\u003cp class=\"hvx-v\"\u003eDown to -22°F\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"hvx-desc-card\"\u003e\n\u003ch3 class=\"hvx-section-title\"\u003eWhat’s Included\u003c\/h3\u003e\n\u003cul class=\"hvx-muted\" style=\"margin: 0; padding-left: 18px;\"\u003e\n\u003cli\u003eIndoor one-way ceiling cassette: CH-RSH06-12MCT1W\u003c\/li\u003e\n\u003cli\u003eOutdoor condenser: CH-RHP06F9-230VO (Hyper)\u003c\/li\u003e\n\u003cli\u003eRemote control (indoor control package)\u003c\/li\u003e\n\u003cli\u003eBuilt-in condensate pump (indoor)\u003c\/li\u003e\n\u003cli\u003eSmart kit capability for app control (setup required)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"hvx-desc-card\"\u003e\n\u003ch3 class=\"hvx-section-title\"\u003eIndoor Specs (CH-RSH06-12MCT1W)\u003c\/h3\u003e\n\u003cdiv class=\"hvx-table-wrap\"\u003e\n\u003ctable class=\"hvx-table\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eSpec\u003c\/th\u003e\n\u003cth\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRefrigerant Type\u003c\/td\u003e\n\u003ctd\u003eR454B\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSystem Type\u003c\/td\u003e\n\u003ctd\u003eSingle Zone\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBTU Rated\u003c\/td\u003e\n\u003ctd\u003e12,000 (capacity selectable: 6K \/ 9K \/ 12K)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower\u003c\/td\u003e\n\u003ctd\u003e208–230V • 1Ph • 60Hz (Voltage Range: 187–253V)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSEER2 \/ EER2\u003c\/td\u003e\n\u003ctd\u003e23 \/ 13\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDehumidification\u003c\/td\u003e\n\u003ctd\u003e3.57 pints\/day\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIndoor Airflow (CFM)\u003c\/td\u003e\n\u003ctd\u003e353.2 \/ 312 \/ 282.5 \/ 247.2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNoise (dB(A))\u003c\/td\u003e\n\u003ctd\u003e41 \/ 37 \/ 33 (H\/M\/L)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUnit Dimensions (W×D×H)\u003c\/td\u003e\n\u003ctd\u003e50.31 × 13.19 × 8.98 in\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNet \/ Gross Weight\u003c\/td\u003e\n\u003ctd\u003e45.19 \/ 82.45 lb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRefrigerant Piping\u003c\/td\u003e\n\u003ctd\u003e1\/4\" Liquid • 3\/8\" Gas\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDrain Pipe Diameter\u003c\/td\u003e\n\u003ctd\u003e3\/4\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Range\u003c\/td\u003e\n\u003ctd\u003eCooling: 60–90°F • Heating: 32–86°F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMinimum Circuit Ampacity\u003c\/td\u003e\n\u003ctd\u003e3 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax Fuse\u003c\/td\u003e\n\u003ctd\u003e15 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePacking Dimensions (WxDxH)\u003c\/td\u003e\n\u003ctd\u003e57.60 × 22.48 × 22.64 in\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"hvx-desc-card\"\u003e\n\u003ch3 class=\"hvx-section-title\"\u003eOutdoor Specs (CH-RHP06F9-230VO)\u003c\/h3\u003e\n\u003cdiv class=\"hvx-table-wrap\"\u003e\n\u003ctable class=\"hvx-table\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eSpec\u003c\/th\u003e\n\u003cth\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRefrigerant Type\u003c\/td\u003e\n\u003ctd\u003eR454B\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBTU Rated\u003c\/td\u003e\n\u003ctd\u003e6,000\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCooling Capacity (Min–Max)\u003c\/td\u003e\n\u003ctd\u003e6,000 (2,300–12,600) BTU\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHeating Capacity (Min–Max)\u003c\/td\u003e\n\u003ctd\u003e7,000 (3,000–11,000) BTU\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHSPF2 (Region IV \/ V)\u003c\/td\u003e\n\u003ctd\u003e14.8 \/ 11.5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCOP\u003c\/td\u003e\n\u003ctd\u003e4.2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAHRI\u003c\/td\u003e\n\u003ctd\u003e215864151\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower\u003c\/td\u003e\n\u003ctd\u003e208–230V • 1Ph • 60Hz (Voltage Range: 187–253V)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax Pipe Length\u003c\/td\u003e\n\u003ctd\u003e82 ft\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax Height Difference\u003c\/td\u003e\n\u003ctd\u003e49.2 ft\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMinimum Circuit Ampacity\u003c\/td\u003e\n\u003ctd\u003e12 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax Fuse\u003c\/td\u003e\n\u003ctd\u003e15 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutdoor Airflow\u003c\/td\u003e\n\u003ctd\u003e1,235.3 CFM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutdoor Noise\u003c\/td\u003e\n\u003ctd\u003e53 dB(A)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUnit Dimensions (W×D×H)\u003c\/td\u003e\n\u003ctd\u003e30.12 × 11.93 × 21.85 in\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNet \/ Gross Weight\u003c\/td\u003e\n\u003ctd\u003e62.17 \/ 67.68 lb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAmbient Temperature\u003c\/td\u003e\n\u003ctd\u003eCooling: -22–122°F • Heating: -22–75°F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAdditional Charge\u003c\/td\u003e\n\u003ctd\u003e0.16 oz\/ft (1\/4\" liquid line)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"hvx-desc-card\"\u003e\n\u003ch3 class=\"hvx-section-title\"\u003eDocuments \u0026amp; Downloads\u003c\/h3\u003e\n\u003cul class=\"hvx-muted\" style=\"margin: 0; padding-left: 18px;\"\u003e\n\u003cli\u003e\u003ca class=\"hvx-link\" href=\"https:\/\/media.cooperandhunter.us\/4380\/CH-RES09-230VO%3ACH-RSH06-12MCT1W.pdf\"\u003eSubmittal Sheet: CH-RES09-230VO + CH-RSH06-12MCT1W\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca class=\"hvx-link\" href=\"https:\/\/media.cooperandhunter.us\/4381\/CH-RES12-230VO%3ACH-RSH06-12MCT1W.pdf\"\u003eSubmittal Sheet: CH-RES12-230VO + CH-RSH06-12MCT1W\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca class=\"hvx-link\" href=\"https:\/\/media.cooperandhunter.us\/4383\/CH-RHP06F9-230VO%3ACH-RSH06-12MCT1W.pdf\"\u003eSubmittal Sheet: CH-RHP06F9-230VO + CH-RSH06-12MCT1W\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca class=\"hvx-link\" href=\"https:\/\/media.cooperandhunter.us\/4384\/CH-RHP09-230VO%3ACH-RSH06-12MCT1W.pdf\"\u003eSubmittal Sheet: CH-RHP09-230VO + CH-RSH06-12MCT1W\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca class=\"hvx-link\" href=\"https:\/\/media.cooperandhunter.us\/4385\/CH-RHP12-230VO%3ACH-RSH06-12MCT1W.pdf\"\u003eSubmittal Sheet: CH-RHP12-230VO + CH-RSH06-12MCT1W\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca class=\"hvx-link\" href=\"https:\/\/media.cooperandhunter.us\/4403\/Owner_s-Manual_One-Way-Cassette.pdf\"\u003eOwner’s Manual: One-Way Cassette\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca class=\"hvx-link\" href=\"https:\/\/media.cooperandhunter.us\/2779\/Remote-controller-manual.pdf\"\u003eRemote Controller Manual\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca class=\"hvx-link\" href=\"https:\/\/media.cooperandhunter.us\/4404\/OneWayCassette-R454B-Leflet.pdf\"\u003eOne-Way Cassette Leaflet (R454B)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca class=\"hvx-link\" href=\"https:\/\/media.cooperandhunter.us\/4118\/Installation-Manual-R454B-Outdoor-units--.pdf\"\u003eOutdoor Units Installation Manual (R454B)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca class=\"hvx-link\" href=\"https:\/\/media.cooperandhunter.us\/4200\/SlimDuct-Leaflet-R454B.pdf\"\u003eSlimDuct Leaflet (R454B)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca class=\"hvx-link\" href=\"https:\/\/media.cooperandhunter.us\/3198\/MultiZone-Combination-HYPER.pdf\"\u003eMultiZone Combination Guide — Hyper\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca class=\"hvx-link\" href=\"https:\/\/media.cooperandhunter.us\/3199\/MultiZone-Combination-Regular.pdf\"\u003eMultiZone Combination Guide — Regular\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca class=\"hvx-link\" href=\"https:\/\/media.cooperandhunter.us\/4154\/CH-RHP06F9-230VO-%2B-CH-PRO06MASTWM-230VI.pdf\"\u003eSubmittal Sheet: CH-RHP06F9-230VO + CH-PRO06MASTWM-230VI\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca class=\"hvx-link\" href=\"https:\/\/media.cooperandhunter.us\/4165\/CH-RHP06F9-230VO-%2B-CH-RH06MASTWM-230VI.pdf\"\u003eSubmittal Sheet: CH-RHP06F9-230VO + CH-RH06MASTWM-230VI\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca class=\"hvx-link\" href=\"https:\/\/media.cooperandhunter.us\/4201\/CH-RHP06F9-230VO-%2B-CH-RS06-12MDT--MS.pdf\"\u003eSubmittal Sheet: CH-RHP06F9-230VO + CH-RS06-12MDT--MS\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp class=\"hvx-muted\" style=\"margin-top: 10px;\"\u003eVideo title (not linked): Cooper\u0026amp;Hunter’s One Way Cassette\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"hvx-desc-card\"\u003e\n\u003ch3 class=\"hvx-section-title\"\u003eImportant\u003c\/h3\u003e\n\u003cul class=\"hvx-muted\" style=\"margin: 0; padding-left: 18px;\"\u003e\n\u003cli\u003eProfessional installation is recommended.\u003c\/li\u003e\n\u003cli\u003eConfirm ENC1 dip switch capacity setting (6K \/ 9K \/ 12K) during commissioning.\u003c\/li\u003e\n\u003cli\u003eMatch line set sizes to the equipment: 1\/4\" liquid and 3\/8\" suction.\u003c\/li\u003e\n\u003cli\u003eVerify the dedicated circuit is sized per equipment MCA and local code.\u003c\/li\u003e\n\u003cli\u003eNeed help choosing equipment? \u003ca class=\"hvx-link\" href=\"https:\/\/hvacsupplies.com\/pages\/contact\"\u003ehvacsupplies.com\/pages\/contact\u003c\/a\u003e • \u003ca class=\"hvx-link\" href=\"tel:+18005438933\"\u003e(800) 543-8933\u003c\/a\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"hvx-desc-card hvx-faq\"\u003e\n\u003ch3 class=\"hvx-section-title\"\u003eFAQs\u003c\/h3\u003e\n\u003cdetails\u003e\n\u003csummary\u003eHow do I change the capacity from 6K to 9K or 12K?\u003c\/summary\u003e\n\u003cp class=\"hvx-muted\"\u003eUse the ENC1 dip switch on the CH-RSH06-12MCT1W to set the desired capacity (6K \/ 9K \/ 12K).\u003c\/p\u003e\n\u003c\/details\u003e\n\u003cdetails\u003e\n\u003csummary\u003eDoes the indoor cassette include a condensate pump?\u003c\/summary\u003e\n\u003cp class=\"hvx-muted\"\u003eYes. The CH-RSH06-12MCT1W includes a built-in condensate pump.\u003c\/p\u003e\n\u003c\/details\u003e\n\u003cdetails\u003e\n\u003csummary\u003eWhat line set sizes are required?\u003c\/summary\u003e\n\u003cp class=\"hvx-muted\"\u003e1\/4\" liquid line and 3\/8\" suction (gas) line.\u003c\/p\u003e\n\u003c\/details\u003e\n\u003cdetails\u003e\n\u003csummary\u003eHow cold can the Hyper outdoor unit operate in heating?\u003c\/summary\u003e\n\u003cp class=\"hvx-muted\"\u003eCH-RHP06F9-230VO supports heating operation down to -22°F ambient.\u003c\/p\u003e\n\u003c\/details\u003e\n\u003cdetails\u003e\n\u003csummary\u003eCan I control the system with an app?\u003c\/summary\u003e\n\u003cp class=\"hvx-muted\"\u003eSmart kit capability supports app control through the C\u0026amp;H platform after setup.\u003c\/p\u003e\n\u003c\/details\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e","brand":"Cooper\u0026Hunter","offers":[{"title":"No installation","offer_id":42694006210603,"sku":"CH-RSH06-12MCT1W + CH-RHP06F9-230VO","price":2415.0,"currency_code":"USD","in_stock":true},{"title":"16FT","offer_id":42694006243371,"sku":"CH-RSH06-12MCT1W + CH-RHP06F9-230VO","price":2596.0,"currency_code":"USD","in_stock":true},{"title":"25FT","offer_id":42694006276139,"sku":"CH-RSH06-12MCT1W + CH-RHP06F9-230VO","price":2643.0,"currency_code":"USD","in_stock":true},{"title":"50FT","offer_id":42694006308907,"sku":"CH-RSH06-12MCT1W + CH-RHP06F9-230VO","price":2863.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0625\/5647\/1339\/files\/2-Zone_Ductless_Mini_Split_AC_Heat_Pump_48000_BTU_23.png?v=1769197641","url":"https:\/\/hvacsupplies.com\/products\/cooper-hunter-6-000-btu-hyper-single-zone-one-way-cassette-minisplit-heat-pump-system-r454b-230v","provider":"HVACSupplies.com","version":"1.0","type":"link"}