{"product_id":"cooper-hunter-48-000-btu-hyper-high-efficiency-multi-position-air-handler-unit-ducted-heat-pump-split-system-r410a-230v","title":"Cooper\u0026Hunter 48,000 BTU Hyper High Efficiency Multi Position Air Handler Unit Ducted Heat Pump Split System R410A 230V","description":"\u003cstyle\u003e\n  :root{\n    --hvx-golden:#FAA819;\n    --hvx-slate:#262626;\n    --hvx-ivory:#F4F1E6;\n    --hvx-border:#e2e0d5;\n    --hvx-card-bg:#ffffff;\n  }\n\n  .hvx-desc{\n    font-family:\"Articulat CF\",system-ui,-apple-system,BlinkMacSystemFont,\"Segoe UI\",sans-serif;\n    color:var(--hvx-slate);\n    line-height:1.6;\n    background:var(--hvx-ivory);\n    padding:18px 18px 20px;\n    border-radius:16px;\n  }\n\n  .hvx-desc-header{\n    border-radius:14px;\n    padding:14px 16px;\n    background:linear-gradient(120deg,var(--hvx-golden),var(--hvx-slate));\n    color:#fff;\n    margin:0 0 16px;\n    box-shadow:0 10px 24px rgba(0,0,0,.22);\n    display:flex;\n    align-items:flex-start;\n    gap:12px;\n    flex-wrap:wrap;\n  }\n\n  .hvx-header-text{display:flex;flex-direction:column;gap:6px;min-width:260px}\n  .hvx-eyebrow{\n    font-size:11px;\n    letter-spacing:.14em;\n    text-transform:uppercase;\n    opacity:.9;\n  }\n  .hvx-title{\n    margin:0;\n    font-family:\"Anton\",\"Impact\",system-ui,-apple-system,BlinkMacSystemFont,\"Segoe UI\",sans-serif;\n    font-size:22px;\n    line-height:1.15;\n  }\n  .hvx-subtitle{margin:0;font-size:14px;opacity:.95}\n\n  .hvx-desc-card{\n    border:1px solid var(--hvx-border);\n    border-radius:14px;\n    background:var(--hvx-card-bg);\n    padding:16px 18px 18px;\n    box-shadow:0 4px 12px rgba(0,0,0,.06);\n    margin:14px 0;\n  }\n\n  .hvx-section-title{\n    margin:0 0 10px;\n    font-family:\"Anton\",\"Impact\",system-ui,-apple-system,BlinkMacSystemFont,\"Segoe UI\",sans-serif;\n    font-size:17px;\n    letter-spacing:.08em;\n    text-transform:uppercase;\n    color:var(--hvx-slate);\n    display:inline-flex;\n    align-items:center;\n    gap:8px;\n  }\n  .hvx-section-title::after{\n    content:\"\";\n    flex:1;\n    height:2px;\n    border-radius:999px;\n    background:linear-gradient(90deg,var(--hvx-golden),transparent);\n    opacity:.9;\n  }\n\n  .hvx-cta{display:flex;flex-wrap:wrap;gap:10px;margin:10px 0 0}\n  .hvx-cta a{\n    display:inline-flex;\n    align-items:center;\n    gap:8px;\n    padding:10px 14px;\n    border-radius:12px;\n    border:1px solid var(--hvx-border);\n    background:#fff;\n    text-decoration:none;\n    color:var(--hvx-slate);\n    font-size:14px;\n    font-weight:700;\n  }\n  .hvx-cta a.primary{\n    background:var(--hvx-slate);\n    color:#fff;\n    border-color:transparent;\n  }\n\n  .hvx-badges{display:flex;flex-wrap:wrap;gap:8px;margin:10px 0 0}\n  .hvx-badge{\n    font-size:12px;\n    border:1px solid var(--hvx-border);\n    border-radius:999px;\n    padding:6px 10px;\n    background:#fff;\n    white-space:nowrap;\n  }\n\n  .hvx-kv{\n    display:grid;\n    grid-template-columns:repeat(4,minmax(160px,1fr));\n    gap:10px;\n    margin-top:10px;\n  }\n  .hvx-kv \u003e div{\n    border:1px solid var(--hvx-border);\n    background:#fff;\n    border-radius:12px;\n    padding:10px 12px;\n    text-align:center;\n  }\n  .hvx-kv strong{display:block}\n\n  .hvx-table{\n    width:100%;\n    border-collapse:collapse;\n    min-width:520px;\n    background:#fff;\n    border:1px solid var(--hvx-border);\n    border-radius:12px;\n    overflow:hidden;\n  }\n  .hvx-table th,.hvx-table td{\n    border-bottom:1px solid var(--hvx-border);\n    padding:10px 12px;\n    vertical-align:top;\n    font-size:14px;\n  }\n  .hvx-table th{ text-align:left; font-weight:800; background:#fff; }\n  .hvx-table tr:nth-child(even) td{ background:#fbfaf6; }\n  .hvx-table tr:last-child td{ border-bottom:none; }\n  .hvx-table-wrap{ overflow:auto; border-radius:12px; }\n\n  .hvx-link{color:var(--hvx-slate); text-decoration:underline; text-underline-offset:2px}\n  .hvx-link:hover{opacity:.85}\n\n  details.hvx-faq{\n    border:1px solid var(--hvx-border);\n    background:#fff;\n    border-radius:12px;\n    padding:10px 12px;\n    margin:8px 0;\n  }\n  details.hvx-faq summary{cursor:pointer;font-weight:800}\n\n  @media(max-width:980px){\n    .hvx-kv{grid-template-columns:repeat(2,minmax(160px,1fr))}\n  }\n  @media(max-width:768px){\n    .hvx-desc{padding:14px 12px 16px;border-radius:12px}\n    .hvx-desc-header{padding:12px;border-radius:12px}\n    .hvx-title{font-size:19px}\n    .hvx-desc-card{padding:14px;margin:10px 0}\n  }\n\u003c\/style\u003e\n\u003cdiv class=\"hvx-desc\"\u003e\n\u003cdiv class=\"hvx-desc-header\"\u003e\n\u003cdiv class=\"hvx-header-text\"\u003e\n\u003cdiv class=\"hvx-eyebrow\"\u003eCooper\u0026amp;Hunter Light Commercial Hyper • Multi-Position AHU • R410A • 208–230V\u003c\/div\u003e\n\u003ch1 class=\"hvx-title\"\u003eCooper\u0026amp;Hunter 48,000 BTU Hyper High Efficiency Multi Position Air Handler Unit Ducted Heat Pump Split System R410A 230V\u003c\/h1\u003e\n\u003cp class=\"hvx-subtitle\"\u003e\u003cstrong\u003eSystem:\u003c\/strong\u003e CH-48AHU + CH-NHPR48LCU-230VO\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv aria-label=\"Contact options\" class=\"hvx-cta\"\u003e\n\u003ca title=\"Contact Us\" href=\"https:\/\/hvacsupplies.com\/pages\/contact\" rel=\"noopener\" class=\"primary\" target=\"_blank\"\u003e CLICK HERE TO CONTACT US FOR CUSTOM QUOTES AND QUESTIONS \u003c\/a\u003e \u003ca title=\"Call Us Now!\" href=\"tel:+18005438933\"\u003e CLICK TO CALL US 800-543-8933 FOR ANY QUESTIONS \u003c\/a\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"hvx-desc-card\"\u003e\n\u003ch2 class=\"hvx-section-title\"\u003eOverview\u003c\/h2\u003e\n\u003cp style=\"margin: 0;\"\u003eCooper\u0026amp;Hunter \u003cstrong\u003emulti-position air handler units\u003c\/strong\u003e are a versatile replacement for traditional ducted systems, designed to connect to \u003cstrong\u003epre-existing ductwork\u003c\/strong\u003e while delivering quieter operation and improved efficiency with a variable-speed fan motor. This bundle pairs the \u003cstrong\u003eCH-48AHU\u003c\/strong\u003e indoor air handler with the \u003cstrong\u003eCH-NHPR48LCU-230VO\u003c\/strong\u003e Light Commercial Hyper outdoor unit for a \u003cstrong\u003esingle-zone\u003c\/strong\u003e, ducted heat pump split system using \u003cstrong\u003eR410A\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp style=\"margin: 10px 0 0;\"\u003eThe AHU supports \u003cstrong\u003evertical, horizontal, or downflow\u003c\/strong\u003e installation and can be connected to a standard \u003cstrong\u003e24V wall thermostat\u003c\/strong\u003e. The Hyper outdoor option provides dependable heating down to \u003cstrong\u003e-22°F\u003c\/strong\u003e ambient.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"hvx-desc-card\"\u003e\n\u003ch2 class=\"hvx-section-title\"\u003eHighlights\u003c\/h2\u003e\n\u003cdiv role=\"list\" class=\"hvx-badges\"\u003e\n\u003cspan role=\"listitem\" class=\"hvx-badge\"\u003eSingle Zone bundle\u003c\/span\u003e \u003cspan role=\"listitem\" class=\"hvx-badge\"\u003eMulti-position install (IDU)\u003c\/span\u003e \u003cspan role=\"listitem\" class=\"hvx-badge\"\u003e24V thermostat compatible\u003c\/span\u003e \u003cspan role=\"listitem\" class=\"hvx-badge\"\u003eHigh static pressure (ESP 0–0.8)\u003c\/span\u003e \u003cspan role=\"listitem\" class=\"hvx-badge\"\u003eHeat to -22°F (ODU)\u003c\/span\u003e \u003cspan role=\"listitem\" class=\"hvx-badge\"\u003eR410A refrigerant\u003c\/span\u003e \u003cspan role=\"listitem\" class=\"hvx-badge\"\u003eIndoor SEER2: 16.2\u003c\/span\u003e \u003cspan role=\"listitem\" class=\"hvx-badge\"\u003eOutdoor SEER2: 14.6\u003c\/span\u003e \u003cspan role=\"listitem\" class=\"hvx-badge\"\u003eLines: 3\/8\" • 5\/8\"\u003c\/span\u003e \u003cspan role=\"listitem\" class=\"hvx-badge\"\u003eMax line: 213.25 ft\u003c\/span\u003e \u003cspan role=\"listitem\" class=\"hvx-badge\"\u003eAHRI Ref: 210799615\u003c\/span\u003e\n\u003c\/div\u003e\n\u003cul style=\"margin: 12px 0 0; padding-left: 18px;\"\u003e\n\u003cli\u003e\n\u003cstrong\u003eDuctwork-friendly:\u003c\/strong\u003e built to integrate with existing ducts for a cleaner retrofit path.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQuiet operation:\u003c\/strong\u003e variable-speed fan motor and staged airflow.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFlexible install:\u003c\/strong\u003e vertical, horizontal, or downflow configurations.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eControl flexibility:\u003c\/strong\u003e compatible with standard 24V thermostat; also supports RG10D remote + wired controller (120X\/120N).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCold-climate heating:\u003c\/strong\u003e outdoor operation down to -22°F ambient in heating mode.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cdiv aria-label=\"At-a-glance\" role=\"list\" class=\"hvx-kv\"\u003e\n\u003cdiv role=\"listitem\"\u003e\n\u003cstrong\u003eIndoor\u003c\/strong\u003eCH-48AHU\u003c\/div\u003e\n\u003cdiv role=\"listitem\"\u003e\n\u003cstrong\u003eOutdoor\u003c\/strong\u003eCH-NHPR48LCU-230VO\u003c\/div\u003e\n\u003cdiv role=\"listitem\"\u003e\n\u003cstrong\u003eESP range\u003c\/strong\u003e0–0.8\u003c\/div\u003e\n\u003cdiv role=\"listitem\"\u003e\n\u003cstrong\u003eMax run\u003c\/strong\u003e213.25 ft\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"hvx-desc-card\"\u003e\n\u003ch2 class=\"hvx-section-title\"\u003eWhat’s Included\u003c\/h2\u003e\n\u003cul style=\"padding-left: 18px; margin: 8px 0;\"\u003e\n\u003cli\u003eIndoor air handler unit: CH-48AHU\u003c\/li\u003e\n\u003cli\u003eOutdoor Light Commercial Hyper condenser: CH-NHPR48LCU-230VO\u003c\/li\u003e\n\u003cli\u003eRemote\/control support: RG10D standard remote \u0026amp; 120X or 120N wire controller compatibility\u003c\/li\u003e\n\u003cli\u003eManufacturer documentation (see Documents \u0026amp; Downloads)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInstallation kits are not included\u003c\/strong\u003e unless selected on the Variant Options (\u003cstrong\u003eNo installation\u003c\/strong\u003e, \u003cstrong\u003e16ft\u003c\/strong\u003e, \u003cstrong\u003e25ft\u003c\/strong\u003e, \u003cstrong\u003e50ft\u003c\/strong\u003e).\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"hvx-desc-card\"\u003e\n\u003ch2 class=\"hvx-section-title\"\u003eIndoor Specs\u003c\/h2\u003e\n\u003cdiv class=\"hvx-table-wrap\"\u003e\n\u003ctable aria-label=\"Indoor air handler specifications\" class=\"hvx-table\"\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eSpec\u003c\/th\u003e\n\u003cth\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCH-48AHU\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSystem type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSingle-zone unit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRefrigerant type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eR410A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBTU rated\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e48,000\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower source\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e208–230V, 1Ph, 60Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eVoltage range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e187–253 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDehumidification\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e10.82 pnt\/day\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEER2\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e8.6\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSEER2\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e16.2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRefrigerant piping (liq\/gas)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3\/8\" \/ 5\/8\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFilter dimensions (W×D)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e19.40 × 20.35 in\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMinimum circuit ampacity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e7.5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMax fuse\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e15\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIndoor noise level (H\/M\/L)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e53.5 \/ 47 \/ 43.5 dB(A)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIndoor air flow\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1,470.59 \/ 1,282.35 \/ 1,094.12 \/ 905.88 CFM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eESP range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0 – 0.8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDrain pipe diameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating range (Cooling)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e60–90°F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating range (Heating)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e32–86°F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eController\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eRG10D standard remote \u0026amp; 120X or 120N wire controller\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eUnit dimensions (W×H×D)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e21.02 × 21.02 × 49.02 in\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNet \/ Gross weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e132.50 \/ 155.87 lb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePacking dimensions (W×D×H)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e26.57 × 24.41 × 52.56 in\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"hvx-desc-card\"\u003e\n\u003ch2 class=\"hvx-section-title\"\u003eOutdoor Specs\u003c\/h2\u003e\n\u003cdiv class=\"hvx-table-wrap\"\u003e\n\u003ctable aria-label=\"Outdoor unit specifications\" class=\"hvx-table\"\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eSpec\u003c\/th\u003e\n\u003cth\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCH-NHPR48LCU-230VO\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSystem type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSingle-zone unit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRefrigerant type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eR410A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBTU rated\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e48,000\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower source\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e208–230V, 1Ph, 60Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eVoltage range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e187–253 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDehumidification\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e10.82 pnt\/day\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRefrigerant piping (liq\/gas)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3\/8\" \/ 5\/8\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMax pipe length\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e213.25 ft\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMax height difference (IDU↔ODU)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e98.42 ft\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCooling capacity (Min\/Max)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e47,000 (9,500–48,500) BTU\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eHeating capacity (Min\/Max)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e48,000 (10,500–55,000) BTU\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSEER2\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e14.6\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEER2\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e7.8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eHSPF2-5\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e7.3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eHSPF2-4\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e8.8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCOP\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2.96\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOutdoor noise level\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e64 dB(A)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOutdoor air flow\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4,500 CFM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMinimum circuit ampacity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e40\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMax fuse\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e50\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAmbient temp (Heating)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-22–75°F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAmbient temp (Cooling)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e5–122°F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eUnit dimensions (W×H×D)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e37.48 × 16.34 × 52.48 in\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNet \/ Gross weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e227.07 \/ 255.73 lb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePacking dimensions (W×D×H)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e43.11 × 19.49 × 58.27 in\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRefrigerant precharge\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e25\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAdditional charge (3\/8\" liquid)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.32\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"hvx-desc-card\"\u003e\n\u003ch2 class=\"hvx-section-title\"\u003eDocuments \u0026amp; Downloads\u003c\/h2\u003e\n\u003cul style=\"padding-left: 18px; margin: 8px 0;\"\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/media.cooperandhunter.us\/3714\/CH-NHPR48LCU-230VO%2BCH-48AHU.pdf\" rel=\"noopener\" class=\"hvx-link\" target=\"_blank\"\u003eSubmittal (PDF) — CH-NHPR48LCU-230VO + CH-48AHU\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/media.cooperandhunter.us\/3466\/CH-N48LCU-230VO-%2B-CH-48AHU.pdf\" rel=\"noopener\" class=\"hvx-link\" target=\"_blank\"\u003eSubmittal (PDF) — CH-N48LCU-230VO + CH-48AHU\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/media.cooperandhunter.us\/4125\/120N-wire-controller---owners-manual.pdf\" rel=\"noopener\" class=\"hvx-link\" target=\"_blank\"\u003e120N Wire Controller Owner’s Manual (PDF)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/media.cooperandhunter.us\/1767\/Manual-AHU-Remote-manual.pdf\" rel=\"noopener\" class=\"hvx-link\" target=\"_blank\"\u003eAHU Remote Manual (PDF)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/media.cooperandhunter.us\/1769\/User-manual-36-60KAHU.pdf\" rel=\"noopener\" class=\"hvx-link\" target=\"_blank\"\u003eUser Manual (PDF) — 36–60K AHU\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/media.cooperandhunter.us\/3753\/AHU-leaflet.pdf\" rel=\"noopener\" class=\"hvx-link\" target=\"_blank\"\u003eAHU Leaflet (PDF)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003eAHRI Directory Reference — 210799615\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"hvx-desc-card\"\u003e\n\u003ch2 class=\"hvx-section-title\"\u003eVideos\u003c\/h2\u003e\n\u003cp style=\"margin: 0 0 8px;\"\u003e\u003cstrong\u003eFeatured video\u003c\/strong\u003e\u003c\/p\u003e\n\u003cdiv style=\"margin: 0 0 12px;\"\u003e\u003ciframe title=\"Multi Position Air Handler\" src=\"https:\/\/www.youtube.com\/embed\/pvnUzLYgcBk\" height=\"315\" width=\"560\"\u003e\n      \u003c\/iframe\u003e\u003c\/div\u003e\n\u003cp style=\"margin: 0 0 6px;\"\u003e\u003cstrong\u003eProducts overview\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul style=\"padding-left: 18px; margin: 0;\"\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/youtu.be\/0kUh03W9qS8\" rel=\"noopener\" class=\"hvx-link\" target=\"_blank\"\u003eCooper\u0026amp;Hunter: Multi Zone AC for the Home\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/youtu.be\/TCcju8Ii6L8\" rel=\"noopener\" class=\"hvx-link\" target=\"_blank\"\u003eMulti-Zone Mini-Split System vs Central A\/C in Home (2019) Cooper\u0026amp;Hunter\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp style=\"margin: 12px 0 6px;\"\u003e\u003cstrong\u003eAHU\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul style=\"padding-left: 18px; margin: 0;\"\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/youtu.be\/pvnUzLYgcBk\" rel=\"noopener\" class=\"hvx-link\" target=\"_blank\"\u003eMulti Position Air Handler\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp style=\"margin: 12px 0 6px;\"\u003e\u003cstrong\u003eOutdoor unit video groups\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul style=\"padding-left: 18px; margin: 0;\"\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/youtu.be\/Cxuiytm_CMo\" rel=\"noopener\" class=\"hvx-link\" target=\"_blank\"\u003eHow to Install Multi Zone Mini Split System (Cooper\u0026amp;Hunter) 2020\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/youtu.be\/JQkth-AM5CE\" rel=\"noopener\" class=\"hvx-link\" target=\"_blank\"\u003eFull Installation of Mini Split Ductless Unit, Step by Step!\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/youtu.be\/7mzwevkxw20\" rel=\"noopener\" class=\"hvx-link\" target=\"_blank\"\u003eTop Tips from Cooper\u0026amp;Hunter Mini Split User Manual\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/youtu.be\/Z7jhBvW4uw8\" rel=\"noopener\" class=\"hvx-link\" target=\"_blank\"\u003eCooper\u0026amp;Hunter New Remote Control (2022)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/youtu.be\/2u0pa2jThCM\" rel=\"noopener\" class=\"hvx-link\" target=\"_blank\"\u003eHVAC Installation Kit: 99.9% Copper Line Sets (Cooper\u0026amp;Hunter)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/youtu.be\/qCWu8HCNl3Q\" rel=\"noopener\" class=\"hvx-link\" target=\"_blank\"\u003eMini Split Indoor Unit Types Explained\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.youtube.com\/watch?v=n00qcO3iIR0\" rel=\"noopener\" class=\"hvx-link\" target=\"_blank\"\u003eCan You Use a Mini Split in EXTREME COLD? Heat Pump vs. Propane Cost Comparison with Thermal Camera\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.youtube.com\/watch?v=5QgZqyFp334\" rel=\"noopener\" class=\"hvx-link\" target=\"_blank\"\u003eWhere To Mount a Mini Split Indoor Wall Hung Unit\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.youtube.com\/watch?v=hxYrOv5bV9Y\" rel=\"noopener\" class=\"hvx-link\" target=\"_blank\"\u003eHow To Wall Mount a Mini Split Outdoor Condenser Unit\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.youtube.com\/watch?v=3DHyShrGUXw\" rel=\"noopener\" class=\"hvx-link\" target=\"_blank\"\u003eAre Mini Split Air Conditioners Worth It? - Top 5 Pros \u0026amp; Cons\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.youtube.com\/watch?v=USU0xujHHL8\" rel=\"noopener\" class=\"hvx-link\" target=\"_blank\"\u003eDoes a Wall Mounted MINISPLIT Need a CONDENSATE TRAP? Ductless vs Ducted Air Handlers!\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.youtube.com\/watch?v=ATk1fx_N_qc\" rel=\"noopener\" class=\"hvx-link\" target=\"_blank\"\u003eMINI SPLIT Parts Explained! Understand What They Do!\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.youtube.com\/watch?v=-GHFRcvQwNA\" rel=\"noopener\" class=\"hvx-link\" target=\"_blank\"\u003eMini Split Failure from Electrical Surges, High and Low Voltage! HOW TO SOLVE IT!\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.youtube.com\/watch?v=ZNRlS2xOcVc\" rel=\"noopener\" class=\"hvx-link\" target=\"_blank\"\u003eFull Installation of an Inverter Minisplit Heat Pump with Indoor Ceiling Cassette\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.youtube.com\/watch?v=BxMwbC_2ow8\" rel=\"noopener\" class=\"hvx-link\" target=\"_blank\"\u003eChecking the Refrigerant Charge on a Running R-410A Inverter MINI SPLIT Unit\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"hvx-desc-card\"\u003e\n\u003ch2 class=\"hvx-section-title\"\u003eImportant\u003c\/h2\u003e\n\u003cul style=\"margin: 0; padding-left: 18px; font-size: 14px;\"\u003e\n\u003cli\u003eConfirm thermostat selection (24V), duct sizing\/static pressure, electrical requirements, line sizes, and maximum line length\/height limits before installation.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInstallation kits are not included\u003c\/strong\u003e unless selected on the Variant Options (No installation, 16ft, 25ft, 50ft).\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"hvx-desc-card\"\u003e\n\u003ch2 class=\"hvx-section-title\"\u003eFAQs\u003c\/h2\u003e\n\u003cdetails open=\"\" class=\"hvx-faq\"\u003e\n\u003csummary\u003eIs this a single-zone system?\u003c\/summary\u003e\n\u003cdiv style=\"margin-top: 8px;\"\u003eYes—this is a \u003cstrong\u003esingle-zone bundle\u003c\/strong\u003e pairing CH-48AHU with CH-NHPR48LCU-230VO.\u003c\/div\u003e\n\u003c\/details\u003e\n\u003cdetails open=\"\" class=\"hvx-faq\"\u003e\n\u003csummary\u003eCan this connect to a standard wall thermostat?\u003c\/summary\u003e\n\u003cdiv style=\"margin-top: 8px;\"\u003eYes. The air handler is compatible with a \u003cstrong\u003estandard 24V wall thermostat\u003c\/strong\u003e.\u003c\/div\u003e\n\u003c\/details\u003e\n\u003cdetails open=\"\" class=\"hvx-faq\"\u003e\n\u003csummary\u003eWhat installation orientations are supported?\u003c\/summary\u003e\n\u003cdiv style=\"margin-top: 8px;\"\u003eThe air handler can be installed \u003cstrong\u003evertically\u003c\/strong\u003e, \u003cstrong\u003ehorizontally\u003c\/strong\u003e, or in a \u003cstrong\u003edownflow\u003c\/strong\u003e configuration.\u003c\/div\u003e\n\u003c\/details\u003e\n\u003cdetails open=\"\" class=\"hvx-faq\"\u003e\n\u003csummary\u003eHow cold can it heat?\u003c\/summary\u003e\n\u003cdiv style=\"margin-top: 8px;\"\u003eThe Hyper outdoor unit operates in heating down to \u003cstrong\u003e-22°F\u003c\/strong\u003e ambient.\u003c\/div\u003e\n\u003c\/details\u003e\n\u003cdetails open=\"\" class=\"hvx-faq\"\u003e\n\u003csummary\u003eAre installation kits included?\u003c\/summary\u003e\n\u003cdiv style=\"margin-top: 8px;\"\u003eNo. Installation kits are only included if selected on the Variant Options (No installation, 16ft, 25ft, 50ft).\u003c\/div\u003e\n\u003c\/details\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e","brand":"Cooper\u0026Hunter","offers":[{"title":"No installation","offer_id":43091909607467,"sku":"CH-48AHU + CH-NHPR48LCU-230VO","price":4195.26,"currency_code":"USD","in_stock":true},{"title":"16FT","offer_id":43091911016491,"sku":"CH-48AHU + CH-NHPR48LCU-230VO","price":4424.76,"currency_code":"USD","in_stock":true},{"title":"25FT","offer_id":43091909640235,"sku":"CH-48AHU + CH-NHPR48LCU-230VO","price":4562.46,"currency_code":"USD","in_stock":true},{"title":"50FT","offer_id":43091909673003,"sku":"CH-48AHU + CH-NHPR48LCU-230VO","price":4888.35,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0625\/5647\/1339\/files\/Untitled_design_19_2.png?v=1771541786","url":"https:\/\/hvacsupplies.com\/products\/cooper-hunter-48-000-btu-hyper-high-efficiency-multi-position-air-handler-unit-ducted-heat-pump-split-system-r410a-230v","provider":"HVACSupplies.com","version":"1.0","type":"link"}