{"product_id":"cooper-hunter-24-000-btu-single-zone-slim-duct-ducted-minisplit-heat-pump-system-r410a-230v","title":"Cooper\u0026Hunter 24,000 BTU Single Zone Slim Duct Ducted Minisplit Heat Pump System R410A 230V","description":"\u003cstyle\u003e\n  :root{\n    --hvx-golden:#FAA819;\n    --hvx-slate:#262626;\n    --hvx-ivory:#F4F1E6;\n    --hvx-border:#e2e0d5;\n    --hvx-card-bg:#ffffff;\n  }\n\n  .hvx-desc{\n    font-family:\"Articulat CF\",system-ui,-apple-system,BlinkMacSystemFont,\"Segoe UI\",sans-serif;\n    color:var(--hvx-slate);\n    line-height:1.6;\n    background:var(--hvx-ivory);\n    padding:18px 18px 20px;\n    border-radius:16px;\n  }\n\n  .hvx-desc-header{\n    border-radius:14px;\n    padding:14px 16px;\n    background:linear-gradient(120deg,var(--hvx-golden),var(--hvx-slate));\n    color:#fff;\n    margin:0 0 16px;\n    box-shadow:0 10px 24px rgba(0,0,0,.22);\n    display:flex;\n    align-items:flex-start;\n    gap:12px;\n    flex-wrap:wrap;\n  }\n\n  .hvx-header-text{display:flex;flex-direction:column;gap:6px;min-width:260px}\n  .hvx-eyebrow{\n    font-size:11px;\n    letter-spacing:.14em;\n    text-transform:uppercase;\n    opacity:.9;\n  }\n  .hvx-title{\n    margin:0;\n    font-family:\"Anton\",\"Impact\",system-ui,-apple-system,BlinkMacSystemFont,\"Segoe UI\",sans-serif;\n    font-size:22px;\n    line-height:1.15;\n  }\n  .hvx-subtitle{margin:0;font-size:14px;opacity:.95}\n\n  .hvx-desc-card{\n    border:1px solid var(--hvx-border);\n    border-radius:14px;\n    background:var(--hvx-card-bg);\n    padding:16px 18px 18px;\n    box-shadow:0 4px 12px rgba(0,0,0,.06);\n    margin:14px 0;\n  }\n\n  .hvx-section-title{\n    margin:0 0 10px;\n    font-family:\"Anton\",\"Impact\",system-ui,-apple-system,BlinkMacSystemFont,\"Segoe UI\",sans-serif;\n    font-size:17px;\n    letter-spacing:.08em;\n    text-transform:uppercase;\n    color:var(--hvx-slate);\n    display:inline-flex;\n    align-items:center;\n    gap:8px;\n  }\n  .hvx-section-title::after{\n    content:\"\";\n    flex:1;\n    height:2px;\n    border-radius:999px;\n    background:linear-gradient(90deg,var(--hvx-golden),transparent);\n    opacity:.9;\n  }\n\n  .hvx-cta{display:flex;flex-wrap:wrap;gap:10px;margin:10px 0 0}\n  .hvx-cta a{\n    display:inline-flex;\n    align-items:center;\n    gap:8px;\n    padding:10px 14px;\n    border-radius:12px;\n    border:1px solid var(--hvx-border);\n    background:#fff;\n    text-decoration:none;\n    color:var(--hvx-slate);\n    font-size:14px;\n    font-weight:700;\n  }\n  .hvx-cta a.primary{\n    background:var(--hvx-slate);\n    color:#fff;\n    border-color:transparent;\n  }\n\n  .hvx-badges{display:flex;flex-wrap:wrap;gap:8px;margin:10px 0 0}\n  .hvx-badge{\n    font-size:12px;\n    border:1px solid var(--hvx-border);\n    border-radius:999px;\n    padding:6px 10px;\n    background:#fff;\n    white-space:nowrap;\n  }\n\n  .hvx-kv{\n    display:grid;\n    grid-template-columns:repeat(4,minmax(160px,1fr));\n    gap:10px;\n    margin-top:10px;\n  }\n  .hvx-kv \u003e div{\n    border:1px solid var(--hvx-border);\n    background:#fff;\n    border-radius:12px;\n    padding:10px 12px;\n    text-align:center;\n  }\n  .hvx-kv strong{display:block}\n\n  .hvx-table{\n    width:100%;\n    border-collapse:collapse;\n    min-width:520px;\n    background:#fff;\n    border:1px solid var(--hvx-border);\n    border-radius:12px;\n    overflow:hidden;\n  }\n  .hvx-table th,.hvx-table td{\n    border-bottom:1px solid var(--hvx-border);\n    padding:10px 12px;\n    vertical-align:top;\n    font-size:14px;\n  }\n  .hvx-table th{ text-align:left; font-weight:800; background:#fff; }\n  .hvx-table tr:nth-child(even) td{ background:#fbfaf6; }\n  .hvx-table tr:last-child td{ border-bottom:none; }\n  .hvx-table-wrap{ overflow:auto; border-radius:12px; }\n\n  .hvx-link{color:var(--hvx-slate); text-decoration:underline; text-underline-offset:2px}\n  .hvx-link:hover{opacity:.85}\n\n  details.hvx-faq{\n    border:1px solid var(--hvx-border);\n    background:#fff;\n    border-radius:12px;\n    padding:10px 12px;\n    margin:8px 0;\n  }\n  details.hvx-faq summary{cursor:pointer;font-weight:800}\n\n  @media(max-width:980px){\n    .hvx-kv{grid-template-columns:repeat(2,minmax(160px,1fr))}\n  }\n  @media(max-width:768px){\n    .hvx-desc{padding:14px 12px 16px;border-radius:12px}\n    .hvx-desc-header{padding:12px;border-radius:12px}\n    .hvx-title{font-size:19px}\n    .hvx-desc-card{padding:14px;margin:10px 0}\n  }\n\u003c\/style\u003e\n\n\u003cdiv class=\"hvx-desc\"\u003e\n  \u003cdiv class=\"hvx-desc-header\"\u003e\n    \u003cdiv class=\"hvx-header-text\"\u003e\n      \u003cdiv class=\"hvx-eyebrow\"\u003eCooper\u0026amp;Hunter Slim Duct • R410A • 208–230V\u003c\/div\u003e\n      \u003ch1 class=\"hvx-title\"\u003eCooper\u0026amp;Hunter 24,000 BTU Single Zone Slim Duct Ducted Minisplit Heat Pump System R410A 230V\u003c\/h1\u003e\n      \u003cp class=\"hvx-subtitle\"\u003e\u003cstrong\u003eSKU:\u003c\/strong\u003e CH-24MDT-W + CH-ES24-230VO\u003c\/p\u003e\n    \u003c\/div\u003e\n  \u003c\/div\u003e\n\n  \u003cdiv aria-label=\"Contact options\" class=\"hvx-cta\"\u003e\n    \u003ca title=\"Contact Us\" rel=\"noopener\" href=\"https:\/\/hvacsupplies.com\/pages\/contact\" class=\"primary\" target=\"_blank\"\u003e\n      CLICK HERE TO CONTACT US FOR CUSTOM QUOTES AND QUESTIONS\n    \u003c\/a\u003e\n    \u003ca title=\"Call Us Now!\" href=\"tel:+18005438933\"\u003e\n      CLICK TO CALL US 800-543-8933 FOR ANY QUESTIONS\n    \u003c\/a\u003e\n  \u003c\/div\u003e\n\n  \u003cdiv class=\"hvx-desc-card\"\u003e\n    \u003ch2 class=\"hvx-section-title\"\u003eOverview\u003c\/h2\u003e\n    \u003cp style=\"margin:0;\"\u003e\n      Cooper\u0026amp;Hunter \u003cstrong\u003eLight Commercial Slim Duct\u003c\/strong\u003e systems deliver an inconspicuous, ducted comfort solution that can be\n      concealed in attics and ceiling crawl spaces—without the energy loss typical of many central ducted systems.\n      This bundle pairs the \u003cstrong\u003eCH-24MDT-W\u003c\/strong\u003e slim duct indoor unit with the \u003cstrong\u003eCH-ES24-230VO\u003c\/strong\u003e outdoor condenser as a\n      \u003cstrong\u003esingle-zone\u003c\/strong\u003e system on \u003cstrong\u003e208–230V\u003c\/strong\u003e power.\n    \u003c\/p\u003e\n    \u003cp style=\"margin:10px 0 0;\"\u003e\n      Slim Duct installation can be highly flexible—duct runs can be directed into separate areas while being collectively controlled by\n      a single thermostat\/controller, making it a clean option where wall-mounted heads are not preferred.\n    \u003c\/p\u003e\n  \u003c\/div\u003e\n\n  \u003cdiv class=\"hvx-desc-card\"\u003e\n    \u003ch2 class=\"hvx-section-title\"\u003eHighlights\u003c\/h2\u003e\n\n    \u003cdiv role=\"list\" class=\"hvx-badges\"\u003e\n      \u003cspan role=\"listitem\" class=\"hvx-badge\"\u003e24,000 BTU class\u003c\/span\u003e\n      \u003cspan role=\"listitem\" class=\"hvx-badge\"\u003eSingle Zone bundle\u003c\/span\u003e\n      \u003cspan role=\"listitem\" class=\"hvx-badge\"\u003e208–230V, 1Ph, 60Hz\u003c\/span\u003e\n      \u003cspan role=\"listitem\" class=\"hvx-badge\"\u003eR410A refrigerant\u003c\/span\u003e\n      \u003cspan role=\"listitem\" class=\"hvx-badge\"\u003eIndoor SEER2: 19.2\u003c\/span\u003e\n      \u003cspan role=\"listitem\" class=\"hvx-badge\"\u003eOutdoor SEER2: 21.2\u003c\/span\u003e\n      \u003cspan role=\"listitem\" class=\"hvx-badge\"\u003eEER2: 12–12.5\u003c\/span\u003e\n      \u003cspan role=\"listitem\" class=\"hvx-badge\"\u003eHSPF2-5: 7.8\u003c\/span\u003e\n      \u003cspan role=\"listitem\" class=\"hvx-badge\"\u003eMax line: 164.04 ft\u003c\/span\u003e\n      \u003cspan role=\"listitem\" class=\"hvx-badge\"\u003eESP range: 0–0.64\u003c\/span\u003e\n      \u003cspan role=\"listitem\" class=\"hvx-badge\"\u003eAHRI Ref: 207742326\u003c\/span\u003e\n    \u003c\/div\u003e\n\n    \u003cul style=\"margin:12px 0 0; padding-left:18px;\"\u003e\n      \u003cli\u003e\n\u003cstrong\u003eHidden, ducted comfort:\u003c\/strong\u003e slim duct design supports discreet installs in attics\/ceilings.\u003c\/li\u003e\n      \u003cli\u003e\n\u003cstrong\u003eFlexible air distribution:\u003c\/strong\u003e ducting can be routed to multiple areas under one zone control.\u003c\/li\u003e\n      \u003cli\u003e\n\u003cstrong\u003eStrong performance range:\u003c\/strong\u003e outdoor ambient cooling down to \u003cstrong\u003e-13°F\u003c\/strong\u003e and up to \u003cstrong\u003e122°F\u003c\/strong\u003e; heating down to \u003cstrong\u003e-13°F\u003c\/strong\u003e.\u003c\/li\u003e\n      \u003cli\u003e\n\u003cstrong\u003eHigh static capability:\u003c\/strong\u003e indoor ESP range \u003cstrong\u003e0–0.64\u003c\/strong\u003e supports duct design flexibility.\u003c\/li\u003e\n      \u003cli\u003e\n\u003cstrong\u003eControl options:\u003c\/strong\u003e RG10K remote plus wired controller compatibility (120X or 120N).\u003c\/li\u003e\n    \u003c\/ul\u003e\n\n    \u003cdiv aria-label=\"At-a-glance\" role=\"list\" class=\"hvx-kv\"\u003e\n      \u003cdiv role=\"listitem\"\u003e\n\u003cstrong\u003eIndoor\u003c\/strong\u003eCH-24MDT-W\u003c\/div\u003e\n      \u003cdiv role=\"listitem\"\u003e\n\u003cstrong\u003eOutdoor\u003c\/strong\u003eCH-ES24-230VO\u003c\/div\u003e\n      \u003cdiv role=\"listitem\"\u003e\n\u003cstrong\u003eLines\u003c\/strong\u003e3\/8\" liquid · 5\/8\" gas\u003c\/div\u003e\n      \u003cdiv role=\"listitem\"\u003e\n\u003cstrong\u003eMax run\u003c\/strong\u003e164.04 ft\u003c\/div\u003e\n    \u003c\/div\u003e\n\n    \u003cp style=\"margin:10px 0 0; font-size:13px;\"\u003e\n      \u003cstrong\u003eNote:\u003c\/strong\u003e The indoor unit spec lists SEER2 \u003cstrong\u003e19.2\u003c\/strong\u003e while the paired outdoor unit lists SEER2 \u003cstrong\u003e21.2\u003c\/strong\u003e.\n      For AHRI-rated performance, use the bundled submittal for \u003cstrong\u003eCH-ES24-230VO + CH-24MDT-W\u003c\/strong\u003e in Documents \u0026amp; Downloads.\n    \u003c\/p\u003e\n  \u003c\/div\u003e\n\n  \u003cdiv class=\"hvx-desc-card\"\u003e\n    \u003ch2 class=\"hvx-section-title\"\u003eWhat’s Included\u003c\/h2\u003e\n    \u003cul style=\"padding-left:18px; margin:8px 0;\"\u003e\n      \u003cli\u003eIndoor slim duct unit: CH-24MDT-W\u003c\/li\u003e\n      \u003cli\u003eOutdoor condenser: CH-ES24-230VO\u003c\/li\u003e\n      \u003cli\u003eRemote control support: RG10K (wired controller compatible: 120X or 120N)\u003c\/li\u003e\n      \u003cli\u003eManufacturer documentation (see Documents \u0026amp; Downloads)\u003c\/li\u003e\n      \u003cli\u003e\n\u003cstrong\u003eInstallation kits are not included\u003c\/strong\u003e unless selected on the Variant Options (\u003cstrong\u003eNo installation\u003c\/strong\u003e, \u003cstrong\u003e16ft\u003c\/strong\u003e, \u003cstrong\u003e25ft\u003c\/strong\u003e, \u003cstrong\u003e50ft\u003c\/strong\u003e).\u003c\/li\u003e\n    \u003c\/ul\u003e\n  \u003c\/div\u003e\n\n  \u003cdiv class=\"hvx-desc-card\"\u003e\n    \u003ch2 class=\"hvx-section-title\"\u003eIndoor Specs\u003c\/h2\u003e\n    \u003cdiv class=\"hvx-table-wrap\"\u003e\n      \u003ctable aria-label=\"Indoor unit specifications\" class=\"hvx-table\"\u003e\n        \u003cthead\u003e\n          \u003ctr\u003e\n\u003cth\u003eSpec\u003c\/th\u003e\n\u003cth\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\n        \u003c\/thead\u003e\n        \u003ctbody\u003e\n          \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCH-24MDT-W\u003c\/td\u003e\n\u003c\/tr\u003e\n          \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSystem type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSingle\/Multi-zone unit (configured here as a single-zone bundle)\u003c\/td\u003e\n\u003c\/tr\u003e\n          \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBTU rated\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e24,000\u003c\/td\u003e\n\u003c\/tr\u003e\n          \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower source\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e208–230V, 1Ph, 60Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n          \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eVoltage range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e187–253 V\u003c\/td\u003e\n\u003c\/tr\u003e\n          \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDehumidification\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4.18 pnt\/day\u003c\/td\u003e\n\u003c\/tr\u003e\n          \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEER2\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e12\u003c\/td\u003e\n\u003c\/tr\u003e\n          \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSEER2\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e19.2\u003c\/td\u003e\n\u003c\/tr\u003e\n          \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRefrigerant piping (liq\/gas)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3\/8\" – 5\/8\"\u003c\/td\u003e\n\u003c\/tr\u003e\n          \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMinimum circuit ampacity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003c\/tr\u003e\n          \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMax fuse\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e15\u003c\/td\u003e\n\u003c\/tr\u003e\n          \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIndoor noise level (H\/M\/L)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e44 \/ 41 \/ 37 dB(A)\u003c\/td\u003e\n\u003c\/tr\u003e\n          \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIndoor air flow\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e775.47 \/ 693.06 \/ 434.88 CFM\u003c\/td\u003e\n\u003c\/tr\u003e\n          \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eESP range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0 – 0.64\u003c\/td\u003e\n\u003c\/tr\u003e\n          \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDrain pipe diameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1\"\u003c\/td\u003e\n\u003c\/tr\u003e\n          \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating range (Cooling)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e62–90°F\u003c\/td\u003e\n\u003c\/tr\u003e\n          \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating range (Heating)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e32–86°F\u003c\/td\u003e\n\u003c\/tr\u003e\n          \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eController\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eRG10K-exclusive remote \u0026amp; 120X or 120N wire controller\u003c\/td\u003e\n\u003c\/tr\u003e\n          \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eUnit dimensions (W×H×D)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e43.31 × 30.47 × 9.80 in\u003c\/td\u003e\n\u003c\/tr\u003e\n          \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNet \/ Gross weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e90.39 \/ 105.82 lb\u003c\/td\u003e\n\u003c\/tr\u003e\n          \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePacking dimensions (W×D×H)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e51.38 × 31.69 × 12.40 in\u003c\/td\u003e\n\u003c\/tr\u003e\n        \u003c\/tbody\u003e\n      \u003c\/table\u003e\n    \u003c\/div\u003e\n  \u003c\/div\u003e\n\n  \u003cdiv class=\"hvx-desc-card\"\u003e\n    \u003ch2 class=\"hvx-section-title\"\u003eOutdoor Specs\u003c\/h2\u003e\n    \u003cdiv class=\"hvx-table-wrap\"\u003e\n      \u003ctable aria-label=\"Outdoor unit specifications\" class=\"hvx-table\"\u003e\n        \u003cthead\u003e\n          \u003ctr\u003e\n\u003cth\u003eSpec\u003c\/th\u003e\n\u003cth\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\n        \u003c\/thead\u003e\n        \u003ctbody\u003e\n          \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCH-ES24-230VO\u003c\/td\u003e\n\u003c\/tr\u003e\n          \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSystem type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSingle-zone unit\u003c\/td\u003e\n\u003c\/tr\u003e\n          \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRefrigerant type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eR410A\u003c\/td\u003e\n\u003c\/tr\u003e\n          \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBTU rated\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e24,000\u003c\/td\u003e\n\u003c\/tr\u003e\n          \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower source\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e208–230V, 1Ph, 60Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n          \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eVoltage range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e187–253 V\u003c\/td\u003e\n\u003c\/tr\u003e\n          \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRefrigerant piping (liq\/gas)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3\/8\" \/ 5\/8\"\u003c\/td\u003e\n\u003c\/tr\u003e\n          \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMax pipe length\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e164.04 ft\u003c\/td\u003e\n\u003c\/tr\u003e\n          \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMax height difference (IDU↔ODU)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e82.02 ft\u003c\/td\u003e\n\u003c\/tr\u003e\n          \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCooling capacity (Min\/Max)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e24,000 (7,700–25,500) BTU\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n          \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eHeating capacity (Min\/Max)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e24,000 (11,600–30,900) BTU\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n          \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSEER2\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e21.2\u003c\/td\u003e\n\u003c\/tr\u003e\n          \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEER2\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e12.5\u003c\/td\u003e\n\u003c\/tr\u003e\n          \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eHSPF2-5\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e7.8\u003c\/td\u003e\n\u003c\/tr\u003e\n          \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eHSPF2-4\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e10.3\u003c\/td\u003e\n\u003c\/tr\u003e\n          \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCOP\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3.66\u003c\/td\u003e\n\u003c\/tr\u003e\n          \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDehumidification\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e6.23 pnt\/day\u003c\/td\u003e\n\u003c\/tr\u003e\n          \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOutdoor noise level\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e61 dB(A)\u003c\/td\u003e\n\u003c\/tr\u003e\n          \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOutdoor air flow\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2,235.29 CFM\u003c\/td\u003e\n\u003c\/tr\u003e\n          \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMinimum circuit ampacity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e23\u003c\/td\u003e\n\u003c\/tr\u003e\n          \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMax fuse\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e30\u003c\/td\u003e\n\u003c\/tr\u003e\n          \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAmbient temp (Heating)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-13–75°F\u003c\/td\u003e\n\u003c\/tr\u003e\n          \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAmbient temp (Cooling)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-13–122°F\u003c\/td\u003e\n\u003c\/tr\u003e\n          \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eUnit dimensions (W×H×D)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e37.24 × 16.14 × 31.89 in\u003c\/td\u003e\n\u003c\/tr\u003e\n          \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNet \/ Gross weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e124.78 \/ 134.92 lb\u003c\/td\u003e\n\u003c\/tr\u003e\n          \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePacking dimensions (W×D×H)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e42.91 × 19.69 × 34.84 in\u003c\/td\u003e\n\u003c\/tr\u003e\n          \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRefrigerant precharge\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e25\u003c\/td\u003e\n\u003c\/tr\u003e\n          \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAdditional charge (3\/8\" liquid)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.32\u003c\/td\u003e\n\u003c\/tr\u003e\n        \u003c\/tbody\u003e\n      \u003c\/table\u003e\n    \u003c\/div\u003e\n  \u003c\/div\u003e\n\n  \u003cdiv class=\"hvx-desc-card\"\u003e\n    \u003ch2 class=\"hvx-section-title\"\u003eDocuments \u0026amp; Downloads\u003c\/h2\u003e\n    \u003cul style=\"padding-left:18px; margin:8px 0;\"\u003e\n      \u003cli\u003e\u003ca rel=\"noopener\" href=\"https:\/\/media.cooperandhunter.us\/3869\/CH-24MDT-W.pdf\" class=\"hvx-link\" target=\"_blank\"\u003eSubmittal (PDF) — CH-24MDT-W\u003c\/a\u003e\u003c\/li\u003e\n      \u003cli\u003e\u003ca rel=\"noopener\" href=\"https:\/\/media.cooperandhunter.us\/3870\/CH-ES24-230VO-%2B-CH-24MDT-W.pdf\" class=\"hvx-link\" target=\"_blank\"\u003eSubmittal (PDF) — CH-ES24-230VO + CH-24MDT-W\u003c\/a\u003e\u003c\/li\u003e\n      \u003cli\u003e\u003ca rel=\"noopener\" href=\"https:\/\/media.cooperandhunter.us\/2279\/Duct-24K-Submittal%C2%A0.pdf\" class=\"hvx-link\" target=\"_blank\"\u003eDuct 24K Submittal (PDF)\u003c\/a\u003e\u003c\/li\u003e\n      \u003cli\u003e\u003ca rel=\"noopener\" href=\"https:\/\/media.cooperandhunter.us\/3014\/Installation-manual-Duct-09-24.pdf\" class=\"hvx-link\" target=\"_blank\"\u003eInstallation Manual (PDF) — Duct 09–24\u003c\/a\u003e\u003c\/li\u003e\n      \u003cli\u003e\u003ca rel=\"noopener\" href=\"https:\/\/media.cooperandhunter.us\/3199\/MultiZone-Combination-Regular.pdf\" class=\"hvx-link\" target=\"_blank\"\u003eMulti-Zone Combination (PDF) — Regular\u003c\/a\u003e\u003c\/li\u003e\n      \u003cli\u003e\u003ca rel=\"noopener\" href=\"https:\/\/media.cooperandhunter.us\/3198\/MultiZone-Combination-HYPER.pdf\" class=\"hvx-link\" target=\"_blank\"\u003eMulti-Zone Combination (PDF) — Hyper\u003c\/a\u003e\u003c\/li\u003e\n      \u003cli\u003eAHRI Directory Listing — AHRI #207742326\u003c\/li\u003e\n    \u003c\/ul\u003e\n  \u003c\/div\u003e\n\n  \u003cdiv class=\"hvx-desc-card\"\u003e\n    \u003ch2 class=\"hvx-section-title\"\u003eVideos\u003c\/h2\u003e\n\n    \u003cp style=\"margin:0 0 8px;\"\u003e\u003cstrong\u003eFeatured video\u003c\/strong\u003e\u003c\/p\u003e\n    \u003cdiv style=\"margin:0 0 12px;\"\u003e\n      \u003ciframe width=\"560\" height=\"315\" src=\"https:\/\/www.youtube.com\/embed\/ieOdKq8yBKY\" title=\"Cooper\u0026amp;Hunter Mini Split Slim Duct Installation\" frameborder=\"0\" allow=\"accelerometer; autoplay; clipboard-write; encrypted-media; gyroscope; picture-in-picture; web-share\" referrerpolicy=\"strict-origin-when-cross-origin\" allowfullscreen\u003e\n      \u003c\/iframe\u003e\n    \u003c\/div\u003e\n\n    \u003cp style=\"margin:0 0 6px;\"\u003e\u003cstrong\u003eMini-split installation videos\u003c\/strong\u003e\u003c\/p\u003e\n    \u003cul style=\"padding-left:18px; margin:0;\"\u003e\n      \u003cli\u003e\u003ca rel=\"noopener\" href=\"https:\/\/youtu.be\/ieOdKq8yBKY\" class=\"hvx-link\" target=\"_blank\"\u003eCooper\u0026amp;Hunter Mini Split Slim Duct Installation\u003c\/a\u003e\u003c\/li\u003e\n    \u003c\/ul\u003e\n\n    \u003cp style=\"margin:12px 0 6px;\"\u003e\u003cstrong\u003eMini-Splits\u003c\/strong\u003e\u003c\/p\u003e\n    \u003cul style=\"padding-left:18px; margin:0;\"\u003e\n      \u003cli\u003e\u003ca rel=\"noopener\" href=\"https:\/\/www.youtube.com\/watch?v=n00qcO3iIR0\" class=\"hvx-link\" target=\"_blank\"\u003eCan You Use a Mini Split in EXTREME COLD? Heat Pump vs. Propane Cost Comparison with Thermal Camera\u003c\/a\u003e\u003c\/li\u003e\n      \u003cli\u003e\u003ca rel=\"noopener\" href=\"https:\/\/www.youtube.com\/watch?v=5QgZqyFp334\" class=\"hvx-link\" target=\"_blank\"\u003eWhere To Mount a Mini Split Indoor Wall Hung Unit\u003c\/a\u003e\u003c\/li\u003e\n      \u003cli\u003e\u003ca rel=\"noopener\" href=\"https:\/\/www.youtube.com\/watch?v=hxYrOv5bV9Y\" class=\"hvx-link\" target=\"_blank\"\u003eHow To Wall Mount a Mini Split Outdoor Condenser Unit\u003c\/a\u003e\u003c\/li\u003e\n      \u003cli\u003e\u003ca rel=\"noopener\" href=\"https:\/\/www.youtube.com\/watch?v=3DHyShrGUXw\" class=\"hvx-link\" target=\"_blank\"\u003eAre Mini Split Air Conditioners Worth It? - Top 5 Pros \u0026amp; Cons\u003c\/a\u003e\u003c\/li\u003e\n      \u003cli\u003e\u003ca rel=\"noopener\" href=\"https:\/\/www.youtube.com\/watch?v=USU0xujHHL8\" class=\"hvx-link\" target=\"_blank\"\u003eDoes a Wall Mounted MINISPLIT Need a CONDENSATE TRAP? Ductless vs Ducted Air Handlers!\u003c\/a\u003e\u003c\/li\u003e\n      \u003cli\u003e\u003ca rel=\"noopener\" href=\"https:\/\/www.youtube.com\/watch?v=ATk1fx_N_qc\" class=\"hvx-link\" target=\"_blank\"\u003eMINI SPLIT Parts Explained! Understand What They Do!\u003c\/a\u003e\u003c\/li\u003e\n      \u003cli\u003e\u003ca rel=\"noopener\" href=\"https:\/\/www.youtube.com\/watch?v=-GHFRcvQwNA\" class=\"hvx-link\" target=\"_blank\"\u003eMini Split Failure from Electrical Surges, High and Low Voltage! HOW TO SOLVE IT!\u003c\/a\u003e\u003c\/li\u003e\n      \u003cli\u003e\u003ca rel=\"noopener\" href=\"https:\/\/www.youtube.com\/watch?v=ZNRlS2xOcVc\" class=\"hvx-link\" target=\"_blank\"\u003eFull Installation of an Inverter Minisplit Heat Pump with Indoor Ceiling Cassette\u003c\/a\u003e\u003c\/li\u003e\n      \u003cli\u003e\u003ca rel=\"noopener\" href=\"https:\/\/www.youtube.com\/watch?v=BxMwbC_2ow8\" class=\"hvx-link\" target=\"_blank\"\u003eChecking the Refrigerant Charge on a Running R-410A Inverter MINI SPLIT Unit\u003c\/a\u003e\u003c\/li\u003e\n      \u003cli\u003e\u003ca rel=\"noopener\" href=\"https:\/\/www.youtube.com\/watch?v=qCWu8HCNl3Q\" class=\"hvx-link\" target=\"_blank\"\u003eMini Split Indoor Unit Types Explained! 5 Types- Applications, Connection Points, Mounting!\u003c\/a\u003e\u003c\/li\u003e\n    \u003c\/ul\u003e\n  \u003c\/div\u003e\n\n  \u003cdiv class=\"hvx-desc-card\"\u003e\n    \u003ch2 class=\"hvx-section-title\"\u003eImportant\u003c\/h2\u003e\n    \u003cp style=\"margin:0; font-size:14px;\"\u003e\n      Professional installation is recommended. Confirm duct design, static pressure requirements, electrical requirements, line sizes,\n      maximum line length\/height limits, and ambient operating limits before installation. Installation kits are not included unless selected\n      on the Variant Options (No installation, 16ft, 25ft, 50ft).\n    \u003c\/p\u003e\n  \u003c\/div\u003e\n\n  \u003cdiv class=\"hvx-desc-card\"\u003e\n    \u003ch2 class=\"hvx-section-title\"\u003eFAQs\u003c\/h2\u003e\n\n    \u003cdetails open class=\"hvx-faq\"\u003e\n      \u003csummary\u003eIs this a single-zone system?\u003c\/summary\u003e\n      \u003cdiv style=\"margin-top:8px;\"\u003e\n        Yes—this listing is a \u003cstrong\u003esingle-zone bundle\u003c\/strong\u003e pairing CH-24MDT-W with CH-ES24-230VO.\n      \u003c\/div\u003e\n    \u003c\/details\u003e\n\n    \u003cdetails open class=\"hvx-faq\"\u003e\n      \u003csummary\u003eWhere is the slim duct indoor unit installed?\u003c\/summary\u003e\n      \u003cdiv style=\"margin-top:8px;\"\u003e\n        Slim duct air handlers are typically hidden in attics, soffits, or ceiling crawl spaces, with short duct runs feeding grilles in the occupied space.\n      \u003c\/div\u003e\n    \u003c\/details\u003e\n\n    \u003cdetails open class=\"hvx-faq\"\u003e\n      \u003csummary\u003eWhat line sizes does this system use?\u003c\/summary\u003e\n      \u003cdiv style=\"margin-top:8px;\"\u003e\n        3\/8\" liquid and 5\/8\" gas.\n      \u003c\/div\u003e\n    \u003c\/details\u003e\n\n    \u003cdetails open class=\"hvx-faq\"\u003e\n      \u003csummary\u003eWhat are the max line length and height difference?\u003c\/summary\u003e\n      \u003cdiv style=\"margin-top:8px;\"\u003e\n        Maximum line length is \u003cstrong\u003e164.04 ft\u003c\/strong\u003e and maximum height difference is \u003cstrong\u003e82.02 ft\u003c\/strong\u003e.\n      \u003c\/div\u003e\n    \u003c\/details\u003e\n\n    \u003cdetails open class=\"hvx-faq\"\u003e\n      \u003csummary\u003eAre installation kits included?\u003c\/summary\u003e\n      \u003cdiv style=\"margin-top:8px;\"\u003e\n        No. Installation kits are only included if selected on the Variant Options (No installation, 16ft, 25ft, 50ft).\n      \u003c\/div\u003e\n    \u003c\/details\u003e\n  \u003c\/div\u003e\n\u003c\/div\u003e\n","brand":"Cooper\u0026Hunter","offers":[{"title":"No installation","offer_id":43088486334507,"sku":"CH-24MDT-W + CH-ES24-230VO","price":2003.43,"currency_code":"USD","in_stock":false},{"title":"16FT","offer_id":43088486367275,"sku":"CH-24MDT-W + CH-ES24-230VO","price":2217.93,"currency_code":"USD","in_stock":false},{"title":"25FT","offer_id":43088486400043,"sku":"CH-24MDT-W + CH-ES24-230VO","price":2346.63,"currency_code":"USD","in_stock":false},{"title":"50FT","offer_id":43088486432811,"sku":"CH-24MDT-W + CH-ES24-230VO","price":2651.22,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0625\/5647\/1339\/files\/SlimDucts_Hyper_Product__Hero_24_2973ec53-997b-457e-bc29-3afad7d2b02d.png?v=1769193873","url":"https:\/\/hvacsupplies.com\/products\/cooper-hunter-24-000-btu-single-zone-slim-duct-ducted-minisplit-heat-pump-system-r410a-230v","provider":"HVACSupplies.com","version":"1.0","type":"link"}