{"product_id":"cooper-hunter-12-000-btu-single-zone-floor-console-minisplit-heat-pump-system-r454b-230v","title":"Cooper\u0026Hunter 12,000 BTU Single Zone Floor Console Minisplit Heat Pump System R454B 230V","description":"\u003c!-- SYSTEM 2: CH-RSH12MMC + CH-RES12-230VO --\u003e\n\u003cstyle\u003e\n    :root{--hvx-golden:#FAA819;--hvx-slate:#262626;--hvx-ivory:#F4F1E6;--hvx-border:#e2e0d5;--hvx-card-bg:#ffffff;}\n    .hvx-desc{background:var(--hvx-ivory);padding:18px;border-radius:18px;font-family:\"Articulat CF\",system-ui,-apple-system,Segoe UI,Roboto,Arial,sans-serif;color:#111;}\n    .hvx-desc-header{background:linear-gradient(120deg,var(--hvx-golden),var(--hvx-slate));border-radius:16px;padding:16px 16px 14px;color:#fff;margin-bottom:14px;}\n    .hvx-eyebrow{font-size:12px;letter-spacing:.12em;text-transform:uppercase;opacity:.9;margin:0 0 6px;}\n    .hvx-title{font-family:\"Anton\",Impact,Haettenschweiler,\"Arial Narrow Bold\",sans-serif;font-size:26px;line-height:1.05;margin:0;}\n    .hvx-desc-card{background:var(--hvx-card-bg);border:1px solid var(--hvx-border);border-radius:16px;padding:14px;margin:12px 0;box-shadow:0 10px 18px rgba(0,0,0,.06);}\n    .hvx-section-title{margin:0 0 10px;font-size:13px;letter-spacing:.12em;text-transform:uppercase;display:inline-block;padding-bottom:6px;position:relative;}\n    .hvx-section-title:after{content:\"\";position:absolute;left:0;bottom:0;height:3px;width:100%;border-radius:99px;background:linear-gradient(90deg,var(--hvx-golden),var(--hvx-slate));}\n    .hvx-badges{display:flex;flex-wrap:wrap;gap:8px;margin:6px 0 10px;}\n    .hvx-badge{display:inline-flex;align-items:center;gap:6px;padding:6px 10px;border-radius:999px;border:1px solid var(--hvx-border);background:#fff;font-size:12px;font-weight:600;}\n    .hvx-grid{display:grid;grid-template-columns:repeat(3,minmax(0,1fr));gap:10px;}\n    .hvx-kv{border:1px solid var(--hvx-border);border-radius:14px;padding:10px;background:#fff;}\n    .hvx-k{font-size:12px;letter-spacing:.08em;text-transform:uppercase;color:#333;margin:0 0 6px;}\n    .hvx-v{font-size:14px;font-weight:700;margin:0;}\n    .hvx-table-wrap{overflow:auto;border-radius:14px;border:1px solid var(--hvx-border);background:#fff;}\n    table.hvx-table{width:100%;border-collapse:collapse;min-width:520px;}\n    .hvx-table th,.hvx-table td{padding:10px 12px;border-bottom:1px solid var(--hvx-border);vertical-align:top;font-size:14px;}\n    .hvx-table th{background:rgba(250,168,25,.12);text-align:left;font-size:12px;letter-spacing:.1em;text-transform:uppercase;}\n    .hvx-table tr:last-child td{border-bottom:none;}\n    .hvx-link{color:#111;text-decoration:none;border-bottom:2px solid rgba(250,168,25,.7);}\n    .hvx-link:hover{border-bottom-color:#111;}\n    .hvx-faq details{border:1px solid var(--hvx-border);border-radius:14px;background:#fff;padding:10px 12px;margin:10px 0;}\n    .hvx-faq summary{cursor:pointer;font-weight:800;}\n    .hvx-muted{color:#333;margin:6px 0 0;}\n    @media (max-width:720px){.hvx-grid{grid-template-columns:1fr;}.hvx-title{font-size:24px;}}\n  \u003c\/style\u003e\n\u003cdiv class=\"hvx-desc\"\u003e\n\u003cdiv class=\"hvx-desc-header\"\u003e\n\u003cp class=\"hvx-eyebrow\"\u003eMini Floor Console + Regular Outdoor • 12K • R454B • 208–230V\u003c\/p\u003e\n\u003ch2 class=\"hvx-title\"\u003eCooper\u0026amp;Hunter 12,000 BTU Single Zone Floor Console Minisplit Heat Pump System R454B 230V\u003c\/h2\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"hvx-desc-card\"\u003e\n\u003ch3 class=\"hvx-section-title\"\u003eOverview\u003c\/h3\u003e\n\u003cp class=\"hvx-muted\"\u003eThis system pairs the CH-RSH12MMC Mini Floor Console indoor unit with the CH-RES12-230VO Regular single-zone outdoor unit. The indoor console supports flexible comfort delivery with humidity and refrigerant sensors plus smart control support. The Regular outdoor unit provides efficient inverter heating and cooling with heating ambient operation listed to -13°F.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"hvx-desc-card\"\u003e\n\u003ch3 class=\"hvx-section-title\"\u003eHighlights\u003c\/h3\u003e\n\u003cdiv class=\"hvx-badges\"\u003e\n\u003cspan class=\"hvx-badge\"\u003eR454B Refrigerant\u003c\/span\u003e \u003cspan class=\"hvx-badge\"\u003eInverter Comfort Control\u003c\/span\u003e \u003cspan class=\"hvx-badge\"\u003eHumidity + Refrigerant Sensors\u003c\/span\u003e \u003cspan class=\"hvx-badge\"\u003eSmart Kit + Remote + Wall Thermostat\u003c\/span\u003e \u003cspan class=\"hvx-badge\"\u003eUp to 24.6 SEER2 (Indoor)\u003c\/span\u003e \u003cspan class=\"hvx-badge\"\u003e1\/4\" \/ 3\/8\" Line Set\u003c\/span\u003e\n\u003c\/div\u003e\n\u003cul class=\"hvx-muted\" style=\"margin: 0 0 12px; padding-left: 18px;\"\u003e\n\u003cli\u003eFloor console design for versatile placement and room comfort control.\u003c\/li\u003e\n\u003cli\u003eEnhanced airflow outlets designed for more even temperature distribution.\u003c\/li\u003e\n\u003cli\u003eEfficient inverter outdoor operation for steady temperature control.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cdiv class=\"hvx-grid\"\u003e\n\u003cdiv class=\"hvx-kv\"\u003e\n\u003cp class=\"hvx-k\"\u003eSystem Search\u003c\/p\u003e\n\u003cp class=\"hvx-v\"\u003e\u003ca class=\"hvx-link\" href=\"https:\/\/hvacsupplies.com\/search?options%5Bprefix%5D=last\u0026amp;q=CH-RSH12MMC+%2B+CH-RES12-230VO\"\u003eCH-RSH12MMC + CH-RES12-230VO\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"hvx-kv\"\u003e\n\u003cp class=\"hvx-k\"\u003eLine Set Size\u003c\/p\u003e\n\u003cp class=\"hvx-v\"\u003e1\/4\" Liquid • 3\/8\" Gas\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"hvx-kv\"\u003e\n\u003cp class=\"hvx-k\"\u003eMax Line Length\u003c\/p\u003e\n\u003cp class=\"hvx-v\"\u003e82 ft\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"hvx-kv\"\u003e\n\u003cp class=\"hvx-k\"\u003eVoltage\u003c\/p\u003e\n\u003cp class=\"hvx-v\"\u003e208–230V (187–253V)\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"hvx-kv\"\u003e\n\u003cp class=\"hvx-k\"\u003eOutdoor Rated BTU\u003c\/p\u003e\n\u003cp class=\"hvx-v\"\u003e12,000\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"hvx-kv\"\u003e\n\u003cp class=\"hvx-k\"\u003eOutdoor AHRI\u003c\/p\u003e\n\u003cp class=\"hvx-v\"\u003e207742320\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"hvx-desc-card\"\u003e\n\u003ch3 class=\"hvx-section-title\"\u003eWhat’s Included\u003c\/h3\u003e\n\u003cul class=\"hvx-muted\" style=\"margin: 0; padding-left: 18px;\"\u003e\n\u003cli\u003eIndoor mini floor console: \u003ca class=\"hvx-link\" href=\"https:\/\/hvacsupplies.com\/search?options%5Bprefix%5D=last\u0026amp;q=CH-RSH12MMC\"\u003eCH-RSH12MMC\u003c\/a\u003e\n\u003c\/li\u003e\n\u003cli\u003eOutdoor condenser (Regular): \u003ca class=\"hvx-link\" href=\"https:\/\/hvacsupplies.com\/search?options%5Bprefix%5D=last\u0026amp;q=CH-RES12-230VO\"\u003eCH-RES12-230VO\u003c\/a\u003e\n\u003c\/li\u003e\n\u003cli\u003eIncluded remote control + wall thermostat support\u003c\/li\u003e\n\u003cli\u003eBuilt-in smart kit capability for app control (setup required)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp class=\"hvx-muted\" style=\"margin-top: 10px;\"\u003eVideo title (not linked): Multi-Zone System with R454B\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"hvx-desc-card\"\u003e\n\u003ch3 class=\"hvx-section-title\"\u003eIndoor Specs (CH-RSH12MMC)\u003c\/h3\u003e\n\u003cdiv class=\"hvx-table-wrap\"\u003e\n\u003ctable class=\"hvx-table\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eSpec\u003c\/th\u003e\n\u003cth\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRefrigerant Type\u003c\/td\u003e\n\u003ctd\u003eR454B\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBTU Rated\u003c\/td\u003e\n\u003ctd\u003e12K\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSEER2 \/ EER2\u003c\/td\u003e\n\u003ctd\u003e25.0 \/ 12.5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower\u003c\/td\u003e\n\u003ctd\u003e208–230V • 1Ph • 60Hz (187–253V)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDehumidification\u003c\/td\u003e\n\u003ctd\u003e3.13 pints\/day\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIndoor Airflow\u003c\/td\u003e\n\u003ctd\u003e441.4 \/ 376.7 \/ 323.7 \/ 188.4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNoise (H\/M\/L)\u003c\/td\u003e\n\u003ctd\u003e40.5 \/ 37 \/ 26.5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions (W×D×H)\u003c\/td\u003e\n\u003ctd\u003e31.26 × 7.87 × 24.45 in\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNet \/ Gross Weight\u003c\/td\u003e\n\u003ctd\u003e32.85 \/ 41.89\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLine Set\u003c\/td\u003e\n\u003ctd\u003e1\/4\" Liquid • 3\/8\" Gas\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDrain Pipe Diameter\u003c\/td\u003e\n\u003ctd\u003e5\/8\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Range\u003c\/td\u003e\n\u003ctd\u003eCooling: 60–90°F • Heating: 32–86°F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMCA \/ Max Fuse\u003c\/td\u003e\n\u003ctd\u003e3A \/ 15A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePacking (W×D×H)\u003c\/td\u003e\n\u003ctd\u003e34.06 × 11.02 × 28.31 in\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eController\u003c\/td\u003e\n\u003ctd\u003eRemote controller\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"hvx-desc-card\"\u003e\n\u003ch3 class=\"hvx-section-title\"\u003eOutdoor Specs (CH-RES12-230VO)\u003c\/h3\u003e\n\u003cdiv class=\"hvx-table-wrap\"\u003e\n\u003ctable class=\"hvx-table\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eSpec\u003c\/th\u003e\n\u003cth\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRefrigerant Type\u003c\/td\u003e\n\u003ctd\u003eR454B\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated BTU\u003c\/td\u003e\n\u003ctd\u003e12,000\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSEER2 \/ EER2\u003c\/td\u003e\n\u003ctd\u003e19 \/ 11.7\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCooling Capacity (Min\/Max)\u003c\/td\u003e\n\u003ctd\u003e11,500 (3,100–13,000) BTU\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHeating Capacity (Min\/Max)\u003c\/td\u003e\n\u003ctd\u003e12,000 (3,700–15,600) BTU\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHSPF2 (Region V \/ IV)\u003c\/td\u003e\n\u003ctd\u003e8 \/ 10.2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCOP\u003c\/td\u003e\n\u003ctd\u003e3.42\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAmbient Temperature\u003c\/td\u003e\n\u003ctd\u003eCooling: -13–122°F • Heating: -13–75°F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax Pipe Length \/ Height Difference\u003c\/td\u003e\n\u003ctd\u003e82 ft \/ 49.2 ft\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutdoor Air Flow\u003c\/td\u003e\n\u003ctd\u003e1,236.1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNoise\u003c\/td\u003e\n\u003ctd\u003e55.5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions (W×D×H)\u003c\/td\u003e\n\u003ctd\u003e30.12 × 11.93 × 21.85 in\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNet \/ Gross Weight\u003c\/td\u003e\n\u003ctd\u003e62.17 \/ 67.68\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMCA \/ Max Fuse\u003c\/td\u003e\n\u003ctd\u003e12A \/ 15A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAdditional Charge (1\/4\" liquid)\u003c\/td\u003e\n\u003ctd\u003e0.16\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAHRI\u003c\/td\u003e\n\u003ctd\u003e207742320\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"hvx-desc-card\"\u003e\n\u003ch3 class=\"hvx-section-title\"\u003eDocuments \u0026amp; Downloads\u003c\/h3\u003e\n\u003cul class=\"hvx-muted\" style=\"margin: 0; padding-left: 18px;\"\u003e\n\u003cli\u003e\n\u003cstrong\u003eSystem Submittal (This Combination)\u003c\/strong\u003e: \u003ca class=\"hvx-link\" href=\"https:\/\/media.cooperandhunter.us\/4462\/CH-RES12-230VO-%2B-CH-RSH12MMC.pdf\"\u003eCH-RES12-230VO + CH-RSH12MMC\u003c\/a\u003e\n\u003c\/li\u003e\n\u003cli style=\"margin-top: 10px;\"\u003e\u003cstrong\u003eIndoor Manuals\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca class=\"hvx-link\" href=\"https:\/\/media.cooperandhunter.us\/4460\/Owners-manual-CH-RSH09-16MMC-%28R454B%29-.pdf\"\u003eOwner’s Manual — CH-RSH09-16MMC (R454B)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca class=\"hvx-link\" href=\"https:\/\/media.cooperandhunter.us\/4461\/Installation-manual-CH-RSH09-16MMC-%28R454B%29-.pdf\"\u003eInstallation Manual — CH-RSH09-16MMC (R454B)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli style=\"margin-top: 10px;\"\u003e\u003cstrong\u003eOutdoor Manuals\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca class=\"hvx-link\" href=\"https:\/\/media.cooperandhunter.us\/4118\/Installation-Manual-R454B-Outdoor-units--.pdf\"\u003eInstallation Manual — R454B Outdoor Units\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca class=\"hvx-link\" href=\"https:\/\/media.cooperandhunter.us\/4200\/SlimDuct-Leaflet-R454B.pdf\"\u003eSlimDuct Leaflet (R454B)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli style=\"margin-top: 10px;\"\u003e\u003cstrong\u003eOutdoor Submittals (CH-RES12-230VO)\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca class=\"hvx-link\" href=\"https:\/\/media.cooperandhunter.us\/4156\/CH-RES12-230VO-%2B-CH-PRO12MASTWM-230VI.pdf\"\u003eCH-RES12-230VO + CH-PRO12MASTWM-230VI\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca class=\"hvx-link\" href=\"https:\/\/media.cooperandhunter.us\/4169\/CH-RES12-230VO-%2B-CH-RH12MASTWM-230VI.pdf\"\u003eCH-RES12-230VO + CH-RH12MASTWM-230VI\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca class=\"hvx-link\" href=\"https:\/\/media.cooperandhunter.us\/4210\/CH-RES12-230VO-%2B-CH-RS06-12MDT--MS.pdf\"\u003eCH-RES12-230VO + CH-RS06-12MDT--MS\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca class=\"hvx-link\" href=\"https:\/\/media.cooperandhunter.us\/4677\/CH-RES12-230VO_CH-RSH12MCT.pdf\"\u003eCH-RES12-230VO + CH-RSH12MCT\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca class=\"hvx-link\" href=\"https:\/\/media.cooperandhunter.us\/4676\/CH-RES12-230VO_CH-RH12MCT.pdf\"\u003eCH-RES12-230VO + CH-RH12MCT\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"hvx-desc-card\"\u003e\n\u003ch3 class=\"hvx-section-title\"\u003eImportant\u003c\/h3\u003e\n\u003cul class=\"hvx-muted\" style=\"margin: 0; padding-left: 18px;\"\u003e\n\u003cli\u003eUse the specified line set size: 1\/4\" liquid and 3\/8\" suction (gas).\u003c\/li\u003e\n\u003cli\u003eConfirm circuit sizing and breaker\/fuse selection per MCA and local code.\u003c\/li\u003e\n\u003cli\u003eSupport: \u003ca class=\"hvx-link\" href=\"https:\/\/hvacsupplies.com\/pages\/contact\"\u003ehvacsupplies.com\/pages\/contact\u003c\/a\u003e • \u003ca class=\"hvx-link\" href=\"tel:+18005438933\"\u003e(800) 543-8933\u003c\/a\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"hvx-desc-card hvx-faq\"\u003e\n\u003ch3 class=\"hvx-section-title\"\u003eFAQs\u003c\/h3\u003e\n\u003cdetails\u003e\n\u003csummary\u003eWhat line set size is required?\u003c\/summary\u003e\n\u003cp class=\"hvx-muted\"\u003e1\/4\" liquid and 3\/8\" suction (gas).\u003c\/p\u003e\n\u003c\/details\u003e\n\u003cdetails\u003e\n\u003csummary\u003eHow cold can this Regular system heat?\u003c\/summary\u003e\n\u003cp class=\"hvx-muted\"\u003eThe outdoor unit’s heating ambient range is listed to -13°F.\u003c\/p\u003e\n\u003c\/details\u003e\n\u003cdetails\u003e\n\u003csummary\u003eWhat control options are supported?\u003c\/summary\u003e\n\u003cp class=\"hvx-muted\"\u003eRemote control, wall thermostat support, and smart kit\/app capability (setup required).\u003c\/p\u003e\n\u003c\/details\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e","brand":"Cooper\u0026Hunter","offers":[{"title":"No installation","offer_id":42694355615787,"sku":"CH-RSH12MMC + CH-RES12-230VO","price":1526.0,"currency_code":"USD","in_stock":true},{"title":"16FT","offer_id":42694355648555,"sku":"CH-RSH12MMC + CH-RES12-230VO","price":1708.0,"currency_code":"USD","in_stock":true},{"title":"25FT","offer_id":42694355681323,"sku":"CH-RSH12MMC + CH-RES12-230VO","price":1754.0,"currency_code":"USD","in_stock":true},{"title":"50FT","offer_id":42694355714091,"sku":"CH-RSH12MMC + CH-RES12-230VO","price":1974.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0625\/5647\/1339\/files\/MFC_Regular_Product_Hero_16_4673ae76-6481-4057-b095-b4808f7bb17d.png?v=1769197002","url":"https:\/\/hvacsupplies.com\/products\/cooper-hunter-12-000-btu-single-zone-floor-console-minisplit-heat-pump-system-r454b-230v","provider":"HVACSupplies.com","version":"1.0","type":"link"}