{"title":"Single Zone Universal Floor\/Ceiling (UFC) Cooper\u0026Hunter","description":null,"products":[{"product_id":"cooper-hunter-18-000-btu-hyper-single-zone-universal-floor-ceiling-minisplit-heat-pump-system-r454b-230v","title":"Cooper\u0026Hunter 18,000 BTU Hyper Single Zone Universal Floor\/Ceiling Minisplit Heat Pump System R454B 230V","description":"\u003c!-- SYSTEM 1: CH-RSH18MFC + CH-RHP18-230VO --\u003e\n\u003cstyle\u003e\n    :root{--hvx-golden:#FAA819;--hvx-slate:#262626;--hvx-ivory:#F4F1E6;--hvx-border:#e2e0d5;--hvx-card-bg:#ffffff;}\n    .hvx-desc{background:var(--hvx-ivory);padding:18px;border-radius:18px;font-family:\"Articulat CF\",system-ui,-apple-system,Segoe UI,Roboto,Arial,sans-serif;color:#111;}\n    .hvx-desc-header{background:linear-gradient(120deg,var(--hvx-golden),var(--hvx-slate));border-radius:16px;padding:16px 16px 14px;color:#fff;margin-bottom:14px;}\n    .hvx-eyebrow{font-size:12px;letter-spacing:.12em;text-transform:uppercase;opacity:.9;margin:0 0 6px;}\n    .hvx-title{font-family:\"Anton\",Impact,Haettenschweiler,\"Arial Narrow Bold\",sans-serif;font-size:26px;line-height:1.05;margin:0;}\n    .hvx-desc-card{background:var(--hvx-card-bg);border:1px solid var(--hvx-border);border-radius:16px;padding:14px;margin:12px 0;box-shadow:0 10px 18px rgba(0,0,0,.06);}\n    .hvx-section-title{margin:0 0 10px;font-size:13px;letter-spacing:.12em;text-transform:uppercase;display:inline-block;padding-bottom:6px;position:relative;}\n    .hvx-section-title:after{content:\"\";position:absolute;left:0;bottom:0;height:3px;width:100%;border-radius:99px;background:linear-gradient(90deg,var(--hvx-golden),var(--hvx-slate));}\n    .hvx-badges{display:flex;flex-wrap:wrap;gap:8px;margin:6px 0 10px;}\n    .hvx-badge{display:inline-flex;align-items:center;gap:6px;padding:6px 10px;border-radius:999px;border:1px solid var(--hvx-border);background:#fff;font-size:12px;font-weight:600;}\n    .hvx-grid{display:grid;grid-template-columns:repeat(3,minmax(0,1fr));gap:10px;}\n    .hvx-kv{border:1px solid var(--hvx-border);border-radius:14px;padding:10px;background:#fff;}\n    .hvx-k{font-size:12px;letter-spacing:.08em;text-transform:uppercase;color:#333;margin:0 0 6px;}\n    .hvx-v{font-size:14px;font-weight:700;margin:0;}\n    .hvx-table-wrap{overflow:auto;border-radius:14px;border:1px solid var(--hvx-border);background:#fff;}\n    table.hvx-table{width:100%;border-collapse:collapse;min-width:520px;}\n    .hvx-table th,.hvx-table td{padding:10px 12px;border-bottom:1px solid var(--hvx-border);vertical-align:top;font-size:14px;}\n    .hvx-table th{background:rgba(250,168,25,.12);text-align:left;font-size:12px;letter-spacing:.1em;text-transform:uppercase;}\n    .hvx-table tr:last-child td{border-bottom:none;}\n    .hvx-link{color:#111;text-decoration:none;border-bottom:2px solid rgba(250,168,25,.7);}\n    .hvx-link:hover{border-bottom-color:#111;}\n    .hvx-faq details{border:1px solid var(--hvx-border);border-radius:14px;background:#fff;padding:10px 12px;margin:10px 0;}\n    .hvx-faq summary{cursor:pointer;font-weight:800;}\n    .hvx-muted{color:#333;margin:6px 0 0;}\n    @media (max-width:720px){.hvx-grid{grid-template-columns:1fr;}.hvx-title{font-size:24px;}}\n  \u003c\/style\u003e\n\u003cdiv class=\"hvx-desc\"\u003e\n\u003cdiv class=\"hvx-desc-header\"\u003e\n\u003cp class=\"hvx-eyebrow\"\u003eUniversal Floor\/Ceiling + Hyper Outdoor • R454B • 208–230V\u003c\/p\u003e\n\u003ch2 class=\"hvx-title\"\u003eCooper\u0026amp;Hunter 18,000 BTU Hyper Single Zone Universal Floor\/Ceiling Minisplit Heat Pump System R454B 230V\u003c\/h2\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"hvx-desc-card\"\u003e\n\u003ch3 class=\"hvx-section-title\"\u003eOverview\u003c\/h3\u003e\n\u003cp class=\"hvx-muted\"\u003eThis system pairs the CH-RSH18MFC Universal Floor\/Ceiling indoor unit with the CH-RHP18-230VO Hyper single-zone outdoor unit. The indoor unit supports horizontal ceiling or vertical wall installation for layout flexibility, plus built-in smart control capability, humidity sensing, and refrigerant sensing. The Hyper outdoor unit adds cold-climate heating performance with heating ambient operation listed down to -22°F.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"hvx-desc-card\"\u003e\n\u003ch3 class=\"hvx-section-title\"\u003eHighlights\u003c\/h3\u003e\n\u003cdiv class=\"hvx-badges\"\u003e\n\u003cspan class=\"hvx-badge\"\u003eR454B Refrigerant\u003c\/span\u003e \u003cspan class=\"hvx-badge\"\u003eFloor or Ceiling Install\u003c\/span\u003e \u003cspan class=\"hvx-badge\"\u003eHyper Heating to -22°F\u003c\/span\u003e \u003cspan class=\"hvx-badge\"\u003eHumidity + Refrigerant Sensors\u003c\/span\u003e \u003cspan class=\"hvx-badge\"\u003eSmart Kit + Remote + Wall Thermostat\u003c\/span\u003e \u003cspan class=\"hvx-badge\"\u003e1\/4\" \/ 1\/2\" Line Set\u003c\/span\u003e \u003cspan class=\"hvx-badge\"\u003eUp to 20.4 SEER2 (Indoor)\u003c\/span\u003e\n\u003c\/div\u003e\n\u003cul style=\"margin: 0 0 12px; padding-left: 18px;\" class=\"hvx-muted\"\u003e\n\u003cli\u003eUniversal mounting options: ceiling-suspended or wall-mounted orientation to fit the space.\u003c\/li\u003e\n\u003cli\u003eSmart control support via built-in smart kit and app connectivity (setup required).\u003c\/li\u003e\n\u003cli\u003eInverter-driven outdoor operation for steady comfort and efficient performance.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cdiv class=\"hvx-grid\"\u003e\n\u003cdiv class=\"hvx-kv\"\u003e\n\u003cp class=\"hvx-k\"\u003eSystem Search\u003c\/p\u003e\n\u003cp class=\"hvx-v\"\u003e\u003ca href=\"https:\/\/hvacsupplies.com\/search?options%5Bprefix%5D=last\u0026amp;q=CH-RSH18MFC+%2B+CH-RHP18-230VO\" class=\"hvx-link\"\u003eCH-RSH18MFC + CH-RHP18-230VO\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"hvx-kv\"\u003e\n\u003cp class=\"hvx-k\"\u003eLine Set Size\u003c\/p\u003e\n\u003cp class=\"hvx-v\"\u003e1\/4\" Liquid • 1\/2\" Gas\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"hvx-kv\"\u003e\n\u003cp class=\"hvx-k\"\u003eMax Line Length\u003c\/p\u003e\n\u003cp class=\"hvx-v\"\u003e98.4 ft\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"hvx-kv\"\u003e\n\u003cp class=\"hvx-k\"\u003eVoltage\u003c\/p\u003e\n\u003cp class=\"hvx-v\"\u003e208–230V (187–253V)\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"hvx-kv\"\u003e\n\u003cp class=\"hvx-k\"\u003eOutdoor Rated BTU\u003c\/p\u003e\n\u003cp class=\"hvx-v\"\u003e18,000\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"hvx-kv\"\u003e\n\u003cp class=\"hvx-k\"\u003eOutdoor AHRI\u003c\/p\u003e\n\u003cp class=\"hvx-v\"\u003e207742320\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"hvx-desc-card\"\u003e\n\u003ch3 class=\"hvx-section-title\"\u003eWhat’s Included\u003c\/h3\u003e\n\u003cul style=\"margin: 0; padding-left: 18px;\" class=\"hvx-muted\"\u003e\n\u003cli\u003eUniversal floor\/ceiling indoor unit: \u003ca href=\"https:\/\/hvacsupplies.com\/search?options%5Bprefix%5D=last\u0026amp;q=CH-RSH18MFC\" class=\"hvx-link\"\u003eCH-RSH18MFC\u003c\/a\u003e\n\u003c\/li\u003e\n\u003cli\u003eHyper outdoor condenser: \u003ca href=\"https:\/\/hvacsupplies.com\/search?options%5Bprefix%5D=last\u0026amp;q=CH-RHP18-230VO\" class=\"hvx-link\"\u003eCH-RHP18-230VO\u003c\/a\u003e\n\u003c\/li\u003e\n\u003cli\u003eIncluded remote control + wall thermostat support\u003c\/li\u003e\n\u003cli\u003eBuilt-in smart kit capability for app control (setup required)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"hvx-desc-card\"\u003e\n\u003ch3 class=\"hvx-section-title\"\u003eIndoor Specs (CH-RSH18MFC)\u003c\/h3\u003e\n\u003cdiv class=\"hvx-table-wrap\"\u003e\n\u003ctable class=\"hvx-table\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eSpec\u003c\/th\u003e\n\u003cth\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated V-Ph-Hz\u003c\/td\u003e\n\u003ctd\u003e208\/230 • 1 • 60\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCooling \/ Heating\u003c\/td\u003e\n\u003ctd\u003e18,000 \/ 18,000 BTU\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMinimum Circuit Ampacity (MCA)\u003c\/td\u003e\n\u003ctd\u003e1.9A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax Fuse\u003c\/td\u003e\n\u003ctd\u003e15A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIndoor Air Flow (Turbo\/Hi\/Mi\/Lo)\u003c\/td\u003e\n\u003ctd\u003e576.6 \/ 574.5 \/ 485.6 \/ 428.0 CFM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNoise (Hi\/Mi\/Lo\/Si)\u003c\/td\u003e\n\u003ctd\u003e43.0 \/ 40.0 \/ 32.0 \/ 29.0 dB(A)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions (W×D×H)\u003c\/td\u003e\n\u003ctd\u003e42.0 × 26.5 × 7.9 in\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePacking (W×D×H)\u003c\/td\u003e\n\u003ctd\u003e45.0 × 29.7 × 12.5 in\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNet \/ Gross Weight\u003c\/td\u003e\n\u003ctd\u003e58.42 \/ 70.55 lb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Range\u003c\/td\u003e\n\u003ctd\u003eCooling: 60–90°F • Heating: 32–86°F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLine Set\u003c\/td\u003e\n\u003ctd\u003e1\/4\" Liquid • 1\/2\" Gas\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"hvx-desc-card\"\u003e\n\u003ch3 class=\"hvx-section-title\"\u003eOutdoor Specs (CH-RHP18-230VO)\u003c\/h3\u003e\n\u003cdiv class=\"hvx-table-wrap\"\u003e\n\u003ctable class=\"hvx-table\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eSpec\u003c\/th\u003e\n\u003cth\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRefrigerant Type\u003c\/td\u003e\n\u003ctd\u003eR454B\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated BTU\u003c\/td\u003e\n\u003ctd\u003e18,000\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSEER2 \/ EER2\u003c\/td\u003e\n\u003ctd\u003e18 \/ 12\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCooling Capacity (Min\/Max)\u003c\/td\u003e\n\u003ctd\u003e17,000 (6,500–18,800) BTU\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHeating Capacity (Min\/Max)\u003c\/td\u003e\n\u003ctd\u003e19,000 (8,900–22,000) BTU\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHSPF2 (Region V \/ IV)\u003c\/td\u003e\n\u003ctd\u003e9 \/ 10.5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAmbient Temperature\u003c\/td\u003e\n\u003ctd\u003eCooling: -22–122°F • Heating: -22–75°F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax Pipe Length \/ Height Difference\u003c\/td\u003e\n\u003ctd\u003e98.4 ft \/ 65.6 ft\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions (W×D×H)\u003c\/td\u003e\n\u003ctd\u003e35.04 × 13.46 × 26.50 in\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNet \/ Gross Weight\u003c\/td\u003e\n\u003ctd\u003e99.87 \/ 107.80 lb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMCA \/ Max Fuse\u003c\/td\u003e\n\u003ctd\u003e19A \/ 20A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAHRI\u003c\/td\u003e\n\u003ctd\u003e207742320\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"hvx-desc-card\"\u003e\n\u003ch3 class=\"hvx-section-title\"\u003eDocuments \u0026amp; Downloads\u003c\/h3\u003e\n\u003cul style=\"margin: 0; padding-left: 18px;\" class=\"hvx-muted\"\u003e\n\u003cli\u003e\n\u003cstrong\u003eSystem Submittal (This Combination)\u003c\/strong\u003e: \u003ca href=\"https:\/\/media.cooperandhunter.us\/4630\/CH-RHP18-230VO_CH-RSH18MFC.pdf\" class=\"hvx-link\"\u003eCH-RHP18-230VO + CH-RSH18MFC\u003c\/a\u003e\n\u003c\/li\u003e\n\u003cli style=\"margin-top: 10px;\"\u003e\n\u003cstrong\u003eOutdoor Manuals\u003c\/strong\u003e\u003cstrong\u003e\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/media.cooperandhunter.us\/4118\/Installation-Manual-R454B-Outdoor-units--.pdf\" class=\"hvx-link\"\u003eInstallation Manual — R454B Outdoor Units\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/media.cooperandhunter.us\/4291\/Floor-Ceiling-Leaflet-2025.pdf\"\u003eUFC Leaflet (R454B)\u003c\/a\u003e\u003cbr\u003e\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli style=\"font-weight: bold;\"\u003e\u003cstrong\u003eIndoor Manuals\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca rel=\"noopener\" href=\"https:\/\/media.cooperandhunter.us\/4289\/Installation-manual-LCFC.pdf\" target=\"_blank\"\u003eInstallation Manual\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/media.cooperandhunter.us\/4291\/Floor-Ceiling-Leaflet-2025.pdf\" target=\"_blank\" rel=\"noopener\"\u003eUFC Leaflet (R454B)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\n\u003ca rel=\"noopener\" href=\"https:\/\/media.cooperandhunter.us\/4290\/Owners-manul-UFC_R454B.pdf\" target=\"_blank\"\u003eOwners Manual\u003c\/a\u003e\u003cbr\u003e\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli style=\"margin-top: 10px;\"\u003e\u003cstrong\u003eOutdoor Submittals (CH-RHP18-230VO)\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/media.cooperandhunter.us\/4158\/CH-RHP18-230VO-%2B-CH-PRO18MASTWM-230VI.pdf\" class=\"hvx-link\"\u003eCH-RHP18-230VO + CH-PRO18MASTWM-230VI\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/media.cooperandhunter.us\/4172\/CH-RHP18-230VO-%2B-CH-RH18MASTWM-230VI.pdf\" class=\"hvx-link\"\u003eCH-RHP18-230VO + CH-RH18MASTWM-230VI\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/media.cooperandhunter.us\/4204\/CH-RHP18-230VO-%2B-CH-RS18MDT-MS.pdf\" class=\"hvx-link\"\u003eCH-RHP18-230VO + CH-RS18MDT-MS\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/media.cooperandhunter.us\/4251\/CH-RHP18-230VO-%2B-CH-RS18MAHU.pdf\" class=\"hvx-link\"\u003eCH-RHP18-230VO + CH-RS18MAHU\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/media.cooperandhunter.us\/4686\/CH-RHP18-230VO_CH-RH18MCT.pdf\" class=\"hvx-link\"\u003eCH-RHP18-230VO + CH-RH18MCT\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/media.cooperandhunter.us\/4687\/CH-RHP18-230VO_CH-RSH18MCT.pdf\" class=\"hvx-link\"\u003eCH-RHP18-230VO + CH-RSH18MCT\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"hvx-desc-card\"\u003e\n\u003ch3 class=\"hvx-section-title\"\u003eImportant\u003c\/h3\u003e\n\u003cul style=\"margin: 0; padding-left: 18px;\" class=\"hvx-muted\"\u003e\n\u003cli\u003eUse the specified line set size: 1\/4\" liquid and 1\/2\" suction (gas).\u003c\/li\u003e\n\u003cli\u003eConfirm circuit sizing and breaker\/fuse selection per MCA and local code.\u003c\/li\u003e\n\u003cli\u003eSupport: \u003ca href=\"https:\/\/hvacsupplies.com\/pages\/contact\" class=\"hvx-link\"\u003ehvacsupplies.com\/pages\/contact\u003c\/a\u003e • \u003ca href=\"tel:+18005438933\" class=\"hvx-link\"\u003e(800) 543-8933\u003c\/a\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"hvx-desc-card hvx-faq\"\u003e\n\u003ch3 class=\"hvx-section-title\"\u003eFAQs\u003c\/h3\u003e\n\u003cdetails\u003e\n\u003csummary\u003eCan the indoor unit be installed on the ceiling or wall?\u003c\/summary\u003e\n\u003cp class=\"hvx-muted\"\u003eYes. The CH-RSH18MFC supports ceiling (horizontal) or wall (vertical) installation.\u003c\/p\u003e\n\u003c\/details\u003e\n\u003cdetails\u003e\n\u003csummary\u003eHow cold can this Hyper system heat?\u003c\/summary\u003e\n\u003cp class=\"hvx-muted\"\u003eThe outdoor unit’s heating ambient range is listed to -22°F.\u003c\/p\u003e\n\u003c\/details\u003e\n\u003cdetails\u003e\n\u003csummary\u003eWhat control options are supported?\u003c\/summary\u003e\n\u003cp class=\"hvx-muted\"\u003eSmart kit\/app capability (setup required), included remote control, and wall thermostat support.\u003c\/p\u003e\n\u003c\/details\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e","brand":"Cooper\u0026Hunter","offers":[{"title":"No installation","offer_id":42694901727275,"sku":"CH-RSH18MFC + CH-RHP18-230VO","price":2587.0,"currency_code":"USD","in_stock":true},{"title":"16FT","offer_id":42694901760043,"sku":"CH-RSH18MFC + CH-RHP18-230VO","price":2796.0,"currency_code":"USD","in_stock":true},{"title":"25FT","offer_id":42694901792811,"sku":"CH-RSH18MFC + CH-RHP18-230VO","price":2841.0,"currency_code":"USD","in_stock":true},{"title":"50FT","offer_id":42694901825579,"sku":"CH-RSH18MFC + CH-RHP18-230VO","price":3044.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0625\/5647\/1339\/files\/2-Zone_Ductless_Mini_Split_AC_Heat_Pump_48000_BTU_21.png?v=1769196773"},{"product_id":"cooper-hunter-18-000-btu-single-zone-universal-floor-ceiling-minisplit-heat-pump-system-r454b-230v","title":"Cooper\u0026Hunter 18,000 BTU Single Zone Universal Floor\/Ceiling Minisplit Heat Pump System R454B 230V","description":"\u003c!-- SYSTEM 2: CH-RSH18MFC + CH-RES18-230VO --\u003e\n\u003cstyle\u003e\n    :root{--hvx-golden:#FAA819;--hvx-slate:#262626;--hvx-ivory:#F4F1E6;--hvx-border:#e2e0d5;--hvx-card-bg:#ffffff;}\n    .hvx-desc{background:var(--hvx-ivory);padding:18px;border-radius:18px;font-family:\"Articulat CF\",system-ui,-apple-system,Segoe UI,Roboto,Arial,sans-serif;color:#111;}\n    .hvx-desc-header{background:linear-gradient(120deg,var(--hvx-golden),var(--hvx-slate));border-radius:16px;padding:16px 16px 14px;color:#fff;margin-bottom:14px;}\n    .hvx-eyebrow{font-size:12px;letter-spacing:.12em;text-transform:uppercase;opacity:.9;margin:0 0 6px;}\n    .hvx-title{font-family:\"Anton\",Impact,Haettenschweiler,\"Arial Narrow Bold\",sans-serif;font-size:26px;line-height:1.05;margin:0;}\n    .hvx-desc-card{background:var(--hvx-card-bg);border:1px solid var(--hvx-border);border-radius:16px;padding:14px;margin:12px 0;box-shadow:0 10px 18px rgba(0,0,0,.06);}\n    .hvx-section-title{margin:0 0 10px;font-size:13px;letter-spacing:.12em;text-transform:uppercase;display:inline-block;padding-bottom:6px;position:relative;}\n    .hvx-section-title:after{content:\"\";position:absolute;left:0;bottom:0;height:3px;width:100%;border-radius:99px;background:linear-gradient(90deg,var(--hvx-golden),var(--hvx-slate));}\n    .hvx-badges{display:flex;flex-wrap:wrap;gap:8px;margin:6px 0 10px;}\n    .hvx-badge{display:inline-flex;align-items:center;gap:6px;padding:6px 10px;border-radius:999px;border:1px solid var(--hvx-border);background:#fff;font-size:12px;font-weight:600;}\n    .hvx-grid{display:grid;grid-template-columns:repeat(3,minmax(0,1fr));gap:10px;}\n    .hvx-kv{border:1px solid var(--hvx-border);border-radius:14px;padding:10px;background:#fff;}\n    .hvx-k{font-size:12px;letter-spacing:.08em;text-transform:uppercase;color:#333;margin:0 0 6px;}\n    .hvx-v{font-size:14px;font-weight:700;margin:0;}\n    .hvx-table-wrap{overflow:auto;border-radius:14px;border:1px solid var(--hvx-border);background:#fff;}\n    table.hvx-table{width:100%;border-collapse:collapse;min-width:520px;}\n    .hvx-table th,.hvx-table td{padding:10px 12px;border-bottom:1px solid var(--hvx-border);vertical-align:top;font-size:14px;}\n    .hvx-table th{background:rgba(250,168,25,.12);text-align:left;font-size:12px;letter-spacing:.1em;text-transform:uppercase;}\n    .hvx-table tr:last-child td{border-bottom:none;}\n    .hvx-link{color:#111;text-decoration:none;border-bottom:2px solid rgba(250,168,25,.7);}\n    .hvx-link:hover{border-bottom-color:#111;}\n    .hvx-faq details{border:1px solid var(--hvx-border);border-radius:14px;background:#fff;padding:10px 12px;margin:10px 0;}\n    .hvx-faq summary{cursor:pointer;font-weight:800;}\n    .hvx-muted{color:#333;margin:6px 0 0;}\n    @media (max-width:720px){.hvx-grid{grid-template-columns:1fr;}.hvx-title{font-size:24px;}}\n  \u003c\/style\u003e\n\u003cdiv class=\"hvx-desc\"\u003e\n\u003cdiv class=\"hvx-desc-header\"\u003e\n\u003cp class=\"hvx-eyebrow\"\u003eUniversal Floor\/Ceiling + Regular Outdoor • R454B • 208–230V\u003c\/p\u003e\n\u003ch2 class=\"hvx-title\"\u003eCooper\u0026amp;Hunter 18,000 BTU Single Zone Universal Floor\/Ceiling Minisplit Heat Pump System R454B 230V\u003c\/h2\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"hvx-desc-card\"\u003e\n\u003ch3 class=\"hvx-section-title\"\u003eOverview\u003c\/h3\u003e\n\u003cp class=\"hvx-muted\"\u003eThis system pairs the CH-RSH18MFC Universal Floor\/Ceiling indoor unit with the CH-RES18-230VO Regular single-zone outdoor unit. The indoor unit supports horizontal ceiling or vertical wall installation for layout flexibility, plus built-in smart control capability, humidity sensing, and refrigerant sensing. The Regular outdoor unit delivers efficient inverter heating and cooling with heating ambient operation listed to -13°F.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"hvx-desc-card\"\u003e\n\u003ch3 class=\"hvx-section-title\"\u003eHighlights\u003c\/h3\u003e\n\u003cdiv class=\"hvx-badges\"\u003e\n\u003cspan class=\"hvx-badge\"\u003eR454B Refrigerant\u003c\/span\u003e \u003cspan class=\"hvx-badge\"\u003eFloor or Ceiling Install\u003c\/span\u003e \u003cspan class=\"hvx-badge\"\u003eInverter Comfort Control\u003c\/span\u003e \u003cspan class=\"hvx-badge\"\u003eHumidity + Refrigerant Sensors\u003c\/span\u003e \u003cspan class=\"hvx-badge\"\u003eSmart Kit + Remote + Wall Thermostat\u003c\/span\u003e \u003cspan class=\"hvx-badge\"\u003e1\/4\" \/ 1\/2\" Line Set\u003c\/span\u003e \u003cspan class=\"hvx-badge\"\u003eUp to 22.3 SEER2 (Indoor)\u003c\/span\u003e\n\u003c\/div\u003e\n\u003cul class=\"hvx-muted\" style=\"margin: 0 0 12px; padding-left: 18px;\"\u003e\n\u003cli\u003eUniversal mounting options: ceiling-suspended or wall-mounted orientation to fit the space.\u003c\/li\u003e\n\u003cli\u003eSmart control support via built-in smart kit and app connectivity (setup required).\u003c\/li\u003e\n\u003cli\u003eEfficient inverter outdoor operation for stable temperatures and day-to-day savings.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cdiv class=\"hvx-grid\"\u003e\n\u003cdiv class=\"hvx-kv\"\u003e\n\u003cp class=\"hvx-k\"\u003eSystem Search\u003c\/p\u003e\n\u003cp class=\"hvx-v\"\u003e\u003ca class=\"hvx-link\" href=\"https:\/\/hvacsupplies.com\/search?options%5Bprefix%5D=last\u0026amp;q=CH-RSH18MFC+%2B+CH-RES18-230VO\"\u003eCH-RSH18MFC + CH-RES18-230VO\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"hvx-kv\"\u003e\n\u003cp class=\"hvx-k\"\u003eLine Set Size\u003c\/p\u003e\n\u003cp class=\"hvx-v\"\u003e1\/4\" Liquid • 1\/2\" Gas\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"hvx-kv\"\u003e\n\u003cp class=\"hvx-k\"\u003eMax Line Length\u003c\/p\u003e\n\u003cp class=\"hvx-v\"\u003e98.4 ft\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"hvx-kv\"\u003e\n\u003cp class=\"hvx-k\"\u003eVoltage\u003c\/p\u003e\n\u003cp class=\"hvx-v\"\u003e208–230V (187–253V)\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"hvx-kv\"\u003e\n\u003cp class=\"hvx-k\"\u003eOutdoor Rated BTU\u003c\/p\u003e\n\u003cp class=\"hvx-v\"\u003e18,000\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"hvx-kv\"\u003e\n\u003cp class=\"hvx-k\"\u003eOutdoor AHRI\u003c\/p\u003e\n\u003cp class=\"hvx-v\"\u003e207742320\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"hvx-desc-card\"\u003e\n\u003ch3 class=\"hvx-section-title\"\u003eWhat’s Included\u003c\/h3\u003e\n\u003cul class=\"hvx-muted\" style=\"margin: 0; padding-left: 18px;\"\u003e\n\u003cli\u003eUniversal floor\/ceiling indoor unit: \u003ca class=\"hvx-link\" href=\"https:\/\/hvacsupplies.com\/search?options%5Bprefix%5D=last\u0026amp;q=CH-RSH18MFC\"\u003eCH-RSH18MFC\u003c\/a\u003e\n\u003c\/li\u003e\n\u003cli\u003eRegular outdoor condenser: \u003ca class=\"hvx-link\" href=\"https:\/\/hvacsupplies.com\/search?options%5Bprefix%5D=last\u0026amp;q=CH-RES18-230VO\"\u003eCH-RES18-230VO\u003c\/a\u003e\n\u003c\/li\u003e\n\u003cli\u003eIncluded remote control + wall thermostat support\u003c\/li\u003e\n\u003cli\u003eBuilt-in smart kit capability for app control (setup required)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"hvx-desc-card\"\u003e\n\u003ch3 class=\"hvx-section-title\"\u003eIndoor Specs (CH-RSH18MFC)\u003c\/h3\u003e\n\u003cdiv class=\"hvx-table-wrap\"\u003e\n\u003ctable class=\"hvx-table\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eSpec\u003c\/th\u003e\n\u003cth\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated V-Ph-Hz\u003c\/td\u003e\n\u003ctd\u003e208\/230 • 1 • 60\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCooling \/ Heating\u003c\/td\u003e\n\u003ctd\u003e18,000 \/ 18,000 BTU\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMinimum Circuit Ampacity (MCA)\u003c\/td\u003e\n\u003ctd\u003e1.9A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax Fuse\u003c\/td\u003e\n\u003ctd\u003e15A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIndoor Air Flow (Turbo\/Hi\/Mi\/Lo)\u003c\/td\u003e\n\u003ctd\u003e576.6 \/ 574.5 \/ 485.6 \/ 428.0 CFM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNoise (Hi\/Mi\/Lo\/Si)\u003c\/td\u003e\n\u003ctd\u003e43.0 \/ 40.0 \/ 32.0 \/ 29.0 dB(A)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions (W×D×H)\u003c\/td\u003e\n\u003ctd\u003e42.0 × 26.5 × 7.9 in\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePacking (W×D×H)\u003c\/td\u003e\n\u003ctd\u003e45.0 × 29.7 × 12.5 in\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNet \/ Gross Weight\u003c\/td\u003e\n\u003ctd\u003e58.42 \/ 70.55 lb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Range\u003c\/td\u003e\n\u003ctd\u003eCooling: 60–90°F • Heating: 32–86°F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLine Set\u003c\/td\u003e\n\u003ctd\u003e1\/4\" Liquid • 1\/2\" Gas\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"hvx-desc-card\"\u003e\n\u003ch3 class=\"hvx-section-title\"\u003eOutdoor Specs (CH-RES18-230VO)\u003c\/h3\u003e\n\u003cdiv class=\"hvx-table-wrap\"\u003e\n\u003ctable class=\"hvx-table\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eSpec\u003c\/th\u003e\n\u003cth\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRefrigerant Type\u003c\/td\u003e\n\u003ctd\u003eR454B\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated BTU\u003c\/td\u003e\n\u003ctd\u003e18,000\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSEER2 \/ EER2\u003c\/td\u003e\n\u003ctd\u003e20 \/ 12.5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCooling Capacity (Min\/Max)\u003c\/td\u003e\n\u003ctd\u003e17,000 (7,000–19,000) BTU\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHeating Capacity (Min\/Max)\u003c\/td\u003e\n\u003ctd\u003e20,000 (5,500–22,000) BTU\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHSPF2 (Region V \/ IV)\u003c\/td\u003e\n\u003ctd\u003e8.2 \/ 10.5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAmbient Temperature\u003c\/td\u003e\n\u003ctd\u003eCooling: -13–122°F • Heating: -13–75°F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax Pipe Length \/ Height Difference\u003c\/td\u003e\n\u003ctd\u003e98.4 ft \/ 65.6 ft\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions (W×D×H)\u003c\/td\u003e\n\u003ctd\u003e35.04 × 13.46 × 26.5 in\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNet \/ Gross Weight\u003c\/td\u003e\n\u003ctd\u003e92.59 \/ 100.31 lb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMCA \/ Max Fuse\u003c\/td\u003e\n\u003ctd\u003e18A \/ 20A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAHRI\u003c\/td\u003e\n\u003ctd\u003e207742320\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"hvx-desc-card\"\u003e\n\u003ch3 class=\"hvx-section-title\"\u003eDocuments \u0026amp; Downloads\u003c\/h3\u003e\n\u003cul class=\"hvx-muted\" style=\"margin: 0; padding-left: 18px;\"\u003e\n\u003cli\u003e\n\u003cstrong\u003eSystem Submittal (This Combination)\u003c\/strong\u003e: \u003ca class=\"hvx-link\" href=\"https:\/\/media.cooperandhunter.us\/4625\/CH-RES18-230VO_CH-RSH18MFC.pdf\"\u003eCH-RES18-230VO + CH-RSH18MFC\u003c\/a\u003e\n\u003c\/li\u003e\n\u003cli style=\"margin-top: 10px;\"\u003e\u003cstrong\u003eOutdoor Manuals\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca class=\"hvx-link\" href=\"https:\/\/media.cooperandhunter.us\/4118\/Installation-Manual-R454B-Outdoor-units--.pdf\"\u003eInstallation Manual — R454B Outdoor Units\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\n\u003ca rel=\"noopener\" href=\"https:\/\/media.cooperandhunter.us\/4291\/Floor-Ceiling-Leaflet-2025.pdf\" target=\"_blank\"\u003eUFC Leaflet (R454B)\u003c\/a\u003e\u003cbr\u003e\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli style=\"font-weight: bold;\"\u003e\u003cstrong\u003eIndoor Manuals\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca rel=\"noopener\" href=\"https:\/\/media.cooperandhunter.us\/4289\/Installation-manual-LCFC.pdf\" target=\"_blank\"\u003eInstallation Manual\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/media.cooperandhunter.us\/4291\/Floor-Ceiling-Leaflet-2025.pdf\" target=\"_blank\" rel=\"noopener\"\u003eUFC Leaflet (R454B)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca rel=\"noopener\" href=\"https:\/\/media.cooperandhunter.us\/4290\/Owners-manul-UFC_R454B.pdf\" target=\"_blank\"\u003eOwners Manual\u003c\/a\u003e\u003c\/li\u003e\n\u003cli style=\"margin-top: 10px;\"\u003e\u003cstrong\u003eOutdoor Submittals (CH-RES18-230VO)\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca class=\"hvx-link\" href=\"https:\/\/media.cooperandhunter.us\/4157\/CH-RES18-230VO-%2B-CH-PRO18MASTWM-230VI.pdf\"\u003eCH-RES18-230VO + CH-PRO18MASTWM-230VI\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca class=\"hvx-link\" href=\"https:\/\/media.cooperandhunter.us\/4171\/CH-RES18-230VO-%2B-CH-RH18MASTWM-230VI.pdf\"\u003eCH-RES18-230VO + CH-RH18MASTWM-230VI\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca class=\"hvx-link\" href=\"https:\/\/media.cooperandhunter.us\/4211\/CH-RES18-230VO-%2B-CH-RS18MDT-MS.pdf\"\u003eCH-RES18-230VO + CH-RS18MDT-MS\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca class=\"hvx-link\" href=\"https:\/\/media.cooperandhunter.us\/4679\/CH-RES18-230VO_CH-RSH18MCT.pdf\"\u003eCH-RES18-230VO + CH-RSH18MCT\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca class=\"hvx-link\" href=\"https:\/\/media.cooperandhunter.us\/4678\/CH-RES18-230VO_CH-RH18MCT.pdf\"\u003eCH-RES18-230VO + CH-RH18MCT\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"hvx-desc-card\"\u003e\n\u003ch3 class=\"hvx-section-title\"\u003eImportant\u003c\/h3\u003e\n\u003cul class=\"hvx-muted\" style=\"margin: 0; padding-left: 18px;\"\u003e\n\u003cli\u003eUse the specified line set size: 1\/4\" liquid and 1\/2\" suction (gas).\u003c\/li\u003e\n\u003cli\u003eConfirm circuit sizing and breaker\/fuse selection per MCA and local code.\u003c\/li\u003e\n\u003cli\u003eSupport: \u003ca class=\"hvx-link\" href=\"https:\/\/hvacsupplies.com\/pages\/contact\"\u003ehvacsupplies.com\/pages\/contact\u003c\/a\u003e • \u003ca class=\"hvx-link\" href=\"tel:+18005438933\"\u003e(800) 543-8933\u003c\/a\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"hvx-desc-card hvx-faq\"\u003e\n\u003ch3 class=\"hvx-section-title\"\u003eFAQs\u003c\/h3\u003e\n\u003cdetails\u003e\n\u003csummary\u003eCan the indoor unit be installed on the ceiling or wall?\u003c\/summary\u003e\n\u003cp class=\"hvx-muted\"\u003eYes. The CH-RSH18MFC supports ceiling (horizontal) or wall (vertical) installation.\u003c\/p\u003e\n\u003c\/details\u003e\n\u003cdetails\u003e\n\u003csummary\u003eHow cold can this Regular system heat?\u003c\/summary\u003e\n\u003cp class=\"hvx-muted\"\u003eThe outdoor unit’s heating ambient range is listed to -13°F.\u003c\/p\u003e\n\u003c\/details\u003e\n\u003cdetails\u003e\n\u003csummary\u003eWhat control options are supported?\u003c\/summary\u003e\n\u003cp class=\"hvx-muted\"\u003eSmart kit\/app capability (setup required), included remote control, and wall thermostat support.\u003c\/p\u003e\n\u003c\/details\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e","brand":"Cooper\u0026Hunter","offers":[{"title":"No installation","offer_id":42694925320235,"sku":"CH-RSH18MFC + CH-RES18-230VO","price":2209.0,"currency_code":"USD","in_stock":true},{"title":"16FT","offer_id":42694925353003,"sku":"CH-RSH18MFC + CH-RES18-230VO","price":2418.0,"currency_code":"USD","in_stock":true},{"title":"25FT","offer_id":42694925385771,"sku":"CH-RSH18MFC + CH-RES18-230VO","price":2462.0,"currency_code":"USD","in_stock":true},{"title":"50FT","offer_id":42694925418539,"sku":"CH-RSH18MFC + CH-RES18-230VO","price":2665.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0625\/5647\/1339\/files\/UniversalFloorCeiling_Hyper_Product_Hero_36_75d9187f-f215-4f64-b11a-17e8dc60ffc3.png?v=1769196751"},{"product_id":"cooper-hunter-24-000-btu-hyper-single-zone-universal-floor-ceiling-minisplit-heat-pump-system-r454b-230v","title":"Cooper\u0026Hunter 24,000 BTU Hyper Single Zone Universal Floor\/Ceiling Minisplit Heat Pump System R454B 230V","description":"\u003c!-- SYSTEM 1: CH-RSH24MFC + CH-RHP24-230VO --\u003e\n\u003cstyle\u003e\n    :root{--hvx-golden:#FAA819;--hvx-slate:#262626;--hvx-ivory:#F4F1E6;--hvx-border:#e2e0d5;--hvx-card-bg:#ffffff;}\n    .hvx-desc{background:var(--hvx-ivory);padding:18px;border-radius:18px;font-family:\"Articulat CF\",system-ui,-apple-system,Segoe UI,Roboto,Arial,sans-serif;color:#111;}\n    .hvx-desc-header{background:linear-gradient(120deg,var(--hvx-golden),var(--hvx-slate));border-radius:16px;padding:16px 16px 14px;color:#fff;margin-bottom:14px;}\n    .hvx-eyebrow{font-size:12px;letter-spacing:.12em;text-transform:uppercase;opacity:.9;margin:0 0 6px;}\n    .hvx-title{font-family:\"Anton\",Impact,Haettenschweiler,\"Arial Narrow Bold\",sans-serif;font-size:26px;line-height:1.05;margin:0;}\n    .hvx-desc-card{background:var(--hvx-card-bg);border:1px solid var(--hvx-border);border-radius:16px;padding:14px;margin:12px 0;box-shadow:0 10px 18px rgba(0,0,0,.06);}\n    .hvx-section-title{margin:0 0 10px;font-size:13px;letter-spacing:.12em;text-transform:uppercase;display:inline-block;padding-bottom:6px;position:relative;}\n    .hvx-section-title:after{content:\"\";position:absolute;left:0;bottom:0;height:3px;width:100%;border-radius:99px;background:linear-gradient(90deg,var(--hvx-golden),var(--hvx-slate));}\n    .hvx-badges{display:flex;flex-wrap:wrap;gap:8px;margin:6px 0 10px;}\n    .hvx-badge{display:inline-flex;align-items:center;gap:6px;padding:6px 10px;border-radius:999px;border:1px solid var(--hvx-border);background:#fff;font-size:12px;font-weight:600;}\n    .hvx-grid{display:grid;grid-template-columns:repeat(3,minmax(0,1fr));gap:10px;}\n    .hvx-kv{border:1px solid var(--hvx-border);border-radius:14px;padding:10px;background:#fff;}\n    .hvx-k{font-size:12px;letter-spacing:.08em;text-transform:uppercase;color:#333;margin:0 0 6px;}\n    .hvx-v{font-size:14px;font-weight:700;margin:0;}\n    .hvx-table-wrap{overflow:auto;border-radius:14px;border:1px solid var(--hvx-border);background:#fff;}\n    table.hvx-table{width:100%;border-collapse:collapse;min-width:520px;}\n    .hvx-table th,.hvx-table td{padding:10px 12px;border-bottom:1px solid var(--hvx-border);vertical-align:top;font-size:14px;}\n    .hvx-table th{background:rgba(250,168,25,.12);text-align:left;font-size:12px;letter-spacing:.1em;text-transform:uppercase;}\n    .hvx-table tr:last-child td{border-bottom:none;}\n    .hvx-link{color:#111;text-decoration:none;border-bottom:2px solid rgba(250,168,25,.7);}\n    .hvx-link:hover{border-bottom-color:#111;}\n    .hvx-faq details{border:1px solid var(--hvx-border);border-radius:14px;background:#fff;padding:10px 12px;margin:10px 0;}\n    .hvx-faq summary{cursor:pointer;font-weight:800;}\n    .hvx-muted{color:#333;margin:6px 0 0;}\n    @media (max-width:720px){.hvx-grid{grid-template-columns:1fr;}.hvx-title{font-size:24px;}}\n  \u003c\/style\u003e\n\u003cdiv class=\"hvx-desc\"\u003e\n\u003cdiv class=\"hvx-desc-header\"\u003e\n\u003cp class=\"hvx-eyebrow\"\u003eUniversal Floor\/Ceiling + Hyper Outdoor • R454B • 208–230V\u003c\/p\u003e\n\u003ch2 class=\"hvx-title\"\u003eCooper\u0026amp;Hunter 24,000 BTU Hyper Single Zone Universal Floor\/Ceiling Minisplit Heat Pump System R454B 230V\u003c\/h2\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"hvx-desc-card\"\u003e\n\u003ch3 class=\"hvx-section-title\"\u003eOverview\u003c\/h3\u003e\n\u003cp class=\"hvx-muted\"\u003eThis system pairs the CH-RSH24MFC Universal Floor\/Ceiling indoor unit with the CH-RHP24-230VO Hyper single-zone outdoor unit. The indoor unit supports horizontal ceiling or vertical wall installation for layout flexibility, plus built-in smart control capability, humidity sensing, and refrigerant sensing. The Hyper outdoor unit adds cold-climate heating performance with heating ambient operation listed down to -22°F.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"hvx-desc-card\"\u003e\n\u003ch3 class=\"hvx-section-title\"\u003eHighlights\u003c\/h3\u003e\n\u003cdiv class=\"hvx-badges\"\u003e\n\u003cspan class=\"hvx-badge\"\u003eR454B Refrigerant\u003c\/span\u003e \u003cspan class=\"hvx-badge\"\u003eFloor or Ceiling Install\u003c\/span\u003e \u003cspan class=\"hvx-badge\"\u003eHyper Heating to -22°F\u003c\/span\u003e \u003cspan class=\"hvx-badge\"\u003eHumidity + Refrigerant Sensors\u003c\/span\u003e \u003cspan class=\"hvx-badge\"\u003eSmart Kit + Remote + Wall Thermostat\u003c\/span\u003e \u003cspan class=\"hvx-badge\"\u003e3\/8\" \/ 5\/8\" Line Set\u003c\/span\u003e \u003cspan class=\"hvx-badge\"\u003eUp to 20.4 SEER2 (Indoor)\u003c\/span\u003e\n\u003c\/div\u003e\n\u003cul class=\"hvx-muted\" style=\"margin: 0 0 12px; padding-left: 18px;\"\u003e\n\u003cli\u003eUniversal mounting options: ceiling-suspended or wall-mounted orientation to fit the space.\u003c\/li\u003e\n\u003cli\u003eSmart control support via built-in smart kit and app connectivity (setup required).\u003c\/li\u003e\n\u003cli\u003eInverter-driven outdoor operation for steady comfort and efficient performance.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cdiv class=\"hvx-grid\"\u003e\n\u003cdiv class=\"hvx-kv\"\u003e\n\u003cp class=\"hvx-k\"\u003eSystem Search\u003c\/p\u003e\n\u003cp class=\"hvx-v\"\u003e\u003ca class=\"hvx-link\" href=\"https:\/\/hvacsupplies.com\/search?options%5Bprefix%5D=last\u0026amp;q=CH-RSH24MFC+%2B+CH-RHP24-230VO\"\u003eCH-RSH24MFC + CH-RHP24-230VO\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"hvx-kv\"\u003e\n\u003cp class=\"hvx-k\"\u003eLine Set Size\u003c\/p\u003e\n\u003cp class=\"hvx-v\"\u003e3\/8\" Liquid • 5\/8\" Gas\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"hvx-kv\"\u003e\n\u003cp class=\"hvx-k\"\u003eMax Line Length\u003c\/p\u003e\n\u003cp class=\"hvx-v\"\u003e164 ft\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"hvx-kv\"\u003e\n\u003cp class=\"hvx-k\"\u003eVoltage\u003c\/p\u003e\n\u003cp class=\"hvx-v\"\u003e208–230V (187–253V)\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"hvx-kv\"\u003e\n\u003cp class=\"hvx-k\"\u003eOutdoor Rated BTU\u003c\/p\u003e\n\u003cp class=\"hvx-v\"\u003e24,000\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"hvx-kv\"\u003e\n\u003cp class=\"hvx-k\"\u003eOutdoor AHRI\u003c\/p\u003e\n\u003cp class=\"hvx-v\"\u003e207742320\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"hvx-desc-card\"\u003e\n\u003ch3 class=\"hvx-section-title\"\u003eWhat’s Included\u003c\/h3\u003e\n\u003cul class=\"hvx-muted\" style=\"margin: 0; padding-left: 18px;\"\u003e\n\u003cli\u003eUniversal floor\/ceiling indoor unit: \u003ca class=\"hvx-link\" href=\"https:\/\/hvacsupplies.com\/search?options%5Bprefix%5D=last\u0026amp;q=CH-RSH24MFC\"\u003eCH-RSH24MFC\u003c\/a\u003e\n\u003c\/li\u003e\n\u003cli\u003eHyper outdoor condenser: \u003ca class=\"hvx-link\" href=\"https:\/\/hvacsupplies.com\/search?options%5Bprefix%5D=last\u0026amp;q=CH-RHP24-230VO\"\u003eCH-RHP24-230VO\u003c\/a\u003e\n\u003c\/li\u003e\n\u003cli\u003eIncluded remote control + wall thermostat support\u003c\/li\u003e\n\u003cli\u003eBuilt-in smart kit capability for app control (setup required)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"hvx-desc-card\"\u003e\n\u003ch3 class=\"hvx-section-title\"\u003eIndoor Specs (CH-RSH24MFC)\u003c\/h3\u003e\n\u003cdiv class=\"hvx-table-wrap\"\u003e\n\u003ctable class=\"hvx-table\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eSpec\u003c\/th\u003e\n\u003cth\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated V-Ph-Hz\u003c\/td\u003e\n\u003ctd\u003e208\/230 • 1 • 60\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCooling \/ Heating\u003c\/td\u003e\n\u003ctd\u003e24,000 \/ 24,000 BTU\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMinimum Circuit Ampacity (MCA)\u003c\/td\u003e\n\u003ctd\u003e2.5A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax Fuse\u003c\/td\u003e\n\u003ctd\u003e15A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIndoor Air Flow (Turbo\/Hi\/Mi\/Lo\/Si)\u003c\/td\u003e\n\u003ctd\u003e735.8 \/ 706.5 \/ 605.3 \/ 452.5 \/ 376.7 CFM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIndoor Noise (Turbo\/Hi\/Mi\/Lo\/Si)\u003c\/td\u003e\n\u003ctd\u003e51.5 \/ 49.5 \/ 45 \/ 34 \/ 29 dB(A)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions (W×D×H)\u003c\/td\u003e\n\u003ctd\u003e42.0 × 26.5 × 7.9 in\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePacking (W×D×H)\u003c\/td\u003e\n\u003ctd\u003e45.0 × 29.7 × 12.5 in\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNet \/ Gross Weight\u003c\/td\u003e\n\u003ctd\u003e61.29 \/ 73.19 lb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Range\u003c\/td\u003e\n\u003ctd\u003eCooling: 60–90°F • Heating: 32–86°F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLine Set\u003c\/td\u003e\n\u003ctd\u003e3\/8\" Liquid • 5\/8\" Gas\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"hvx-desc-card\"\u003e\n\u003ch3 class=\"hvx-section-title\"\u003eOutdoor Specs (CH-RHP24-230VO)\u003c\/h3\u003e\n\u003cdiv class=\"hvx-table-wrap\"\u003e\n\u003ctable class=\"hvx-table\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eSpec\u003c\/th\u003e\n\u003cth\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRefrigerant Type\u003c\/td\u003e\n\u003ctd\u003eR454B\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated BTU\u003c\/td\u003e\n\u003ctd\u003e24,000\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCooling Capacity (Min\/Max)\u003c\/td\u003e\n\u003ctd\u003e24,000 (12,600–27,900) BTU\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHeating Capacity (Min\/Max)\u003c\/td\u003e\n\u003ctd\u003e29,000 (11,800–29,700) BTU\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHSPF2 (Region V \/ IV)\u003c\/td\u003e\n\u003ctd\u003e9.8 \/ 13.5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAmbient Temperature\u003c\/td\u003e\n\u003ctd\u003eCooling: -22–122°F • Heating: -22–75°F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax Pipe Length \/ Height Difference\u003c\/td\u003e\n\u003ctd\u003e164 ft \/ 82 ft\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions (W×D×H)\u003c\/td\u003e\n\u003ctd\u003e37.24 × 16.14 × 31.89 in\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNet \/ Gross Weight\u003c\/td\u003e\n\u003ctd\u003e130.29 \/ 141.31 lb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMCA \/ Max Fuse\u003c\/td\u003e\n\u003ctd\u003e24.9A \/ 25A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutdoor Noise\u003c\/td\u003e\n\u003ctd\u003e61.5 dB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAHRI\u003c\/td\u003e\n\u003ctd\u003e207742320\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"hvx-desc-card\"\u003e\n\u003ch3 class=\"hvx-section-title\"\u003eDocuments \u0026amp; Downloads\u003c\/h3\u003e\n\u003cul class=\"hvx-muted\" style=\"margin: 0; padding-left: 18px;\"\u003e\n\u003cli\u003e\n\u003cstrong\u003eSystem Submittal (This Combination)\u003c\/strong\u003e: \u003ca class=\"hvx-link\" href=\"https:\/\/media.cooperandhunter.us\/4631\/CH-RHP24-230VO_CH-RSH24MFC.pdf\"\u003eCH-RHP24-230VO + CH-RSH24MFC\u003c\/a\u003e\n\u003c\/li\u003e\n\u003cli style=\"margin-top: 10px;\"\u003e\u003cstrong\u003eOutdoor Manuals\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca class=\"hvx-link\" href=\"https:\/\/media.cooperandhunter.us\/4118\/Installation-Manual-R454B-Outdoor-units--.pdf\"\u003eInstallation Manual — R454B Outdoor Units\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/media.cooperandhunter.us\/4291\/Floor-Ceiling-Leaflet-2025.pdf\"\u003eUFC Leaflet (R454B)\u003c\/a\u003e\u003cbr\u003e\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli style=\"font-weight: bold;\"\u003e\u003cstrong\u003eIndoor Manuals\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca rel=\"noopener\" href=\"https:\/\/media.cooperandhunter.us\/4289\/Installation-manual-LCFC.pdf\" target=\"_blank\"\u003eInstallation Manual\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca rel=\"noopener\" href=\"https:\/\/media.cooperandhunter.us\/4291\/Floor-Ceiling-Leaflet-2025.pdf\" target=\"_blank\"\u003eUFC Leaflet (R454B)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca rel=\"noopener\" href=\"https:\/\/media.cooperandhunter.us\/4290\/Owners-manul-UFC_R454B.pdf\" target=\"_blank\"\u003eOwners Manual\u003c\/a\u003e\u003c\/li\u003e\n\u003cli style=\"margin-top: 10px;\"\u003e\u003cstrong\u003eOutdoor Submittals (CH-RHP24-230VO)\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca class=\"hvx-link\" href=\"https:\/\/media.cooperandhunter.us\/3959\/CH-RHP24-230VO-%2B-CH-RS24MAHU.pdf\"\u003eCH-RHP24-230VO + CH-RS24MAHU\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca class=\"hvx-link\" href=\"https:\/\/media.cooperandhunter.us\/4160\/CH-RHP24-230VO-%2B-CH-PRO24MASTWM-230VI.pdf\"\u003eCH-RHP24-230VO + CH-PRO24MASTWM-230VI\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca class=\"hvx-link\" href=\"https:\/\/media.cooperandhunter.us\/4174\/CH-RHP24-230VO-%2B-CH-RH24MASTWM-230VI.pdf\"\u003eCH-RHP24-230VO + CH-RH24MASTWM-230VI\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca class=\"hvx-link\" href=\"https:\/\/media.cooperandhunter.us\/4205\/CH-RHP24-230VO-%2B-CH-RS24MDT-HS.pdf\"\u003eCH-RHP24-230VO + CH-RS24MDT-HS\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca class=\"hvx-link\" href=\"https:\/\/media.cooperandhunter.us\/4688\/CH-RHP24-230VO_CH-RH24MCT.pdf\"\u003eCH-RHP24-230VO + CH-RH24MCT\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"hvx-desc-card\"\u003e\n\u003ch3 class=\"hvx-section-title\"\u003eImportant\u003c\/h3\u003e\n\u003cul class=\"hvx-muted\" style=\"margin: 0; padding-left: 18px;\"\u003e\n\u003cli\u003eUse the specified line set size: 3\/8\" liquid and 5\/8\" suction (gas).\u003c\/li\u003e\n\u003cli\u003eConfirm circuit sizing and breaker\/fuse selection per MCA and local code.\u003c\/li\u003e\n\u003cli\u003eSupport: \u003ca class=\"hvx-link\" href=\"https:\/\/hvacsupplies.com\/pages\/contact\"\u003ehvacsupplies.com\/pages\/contact\u003c\/a\u003e • \u003ca class=\"hvx-link\" href=\"tel:+18005438933\"\u003e(800) 543-8933\u003c\/a\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"hvx-desc-card hvx-faq\"\u003e\n\u003ch3 class=\"hvx-section-title\"\u003eFAQs\u003c\/h3\u003e\n\u003cdetails\u003e\n\u003csummary\u003eCan the indoor unit be installed on the ceiling or wall?\u003c\/summary\u003e\n\u003cp class=\"hvx-muted\"\u003eYes. The CH-RSH24MFC supports ceiling (horizontal) or wall (vertical) installation.\u003c\/p\u003e\n\u003c\/details\u003e\n\u003cdetails\u003e\n\u003csummary\u003eHow cold can this Hyper system heat?\u003c\/summary\u003e\n\u003cp class=\"hvx-muted\"\u003eThe outdoor unit’s heating ambient range is listed to -22°F.\u003c\/p\u003e\n\u003c\/details\u003e\n\u003cdetails\u003e\n\u003csummary\u003eWhat line set size does this 24K system use?\u003c\/summary\u003e\n\u003cp class=\"hvx-muted\"\u003eThis pairing uses a 3\/8\" liquid line and a 5\/8\" gas (suction) line.\u003c\/p\u003e\n\u003c\/details\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e","brand":"Cooper\u0026Hunter","offers":[{"title":"No installation","offer_id":42694967885867,"sku":"CH-RSH24MFC + CH-RHP24-230VO","price":2909.0,"currency_code":"USD","in_stock":true},{"title":"16FT","offer_id":42694967918635,"sku":"CH-RSH24MFC + CH-RHP24-230VO","price":3125.0,"currency_code":"USD","in_stock":true},{"title":"25FT","offer_id":42694967951403,"sku":"CH-RSH24MFC + CH-RHP24-230VO","price":3255.0,"currency_code":"USD","in_stock":true},{"title":"50FT","offer_id":42694967984171,"sku":"CH-RSH24MFC + CH-RHP24-230VO","price":3561.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0625\/5647\/1339\/files\/2-Zone_Ductless_Mini_Split_AC_Heat_Pump_48000_BTU_21.png?v=1769196773"},{"product_id":"cooper-hunter-24-000-btu-single-zone-universal-floor-ceiling-minisplit-heat-pump-system-r454b-230v","title":"Cooper\u0026Hunter 24,000 BTU Single Zone Universal Floor\/Ceiling Minisplit Heat Pump System R454B 230V","description":"\u003c!-- SYSTEM 1: CH-RSH24MFC + CH-RHP24-230VO --\u003e\n\u003cstyle\u003e\n    :root{--hvx-golden:#FAA819;--hvx-slate:#262626;--hvx-ivory:#F4F1E6;--hvx-border:#e2e0d5;--hvx-card-bg:#ffffff;}\n    .hvx-desc{background:var(--hvx-ivory);padding:18px;border-radius:18px;font-family:\"Articulat CF\",system-ui,-apple-system,Segoe UI,Roboto,Arial,sans-serif;color:#111;}\n    .hvx-desc-header{background:linear-gradient(120deg,var(--hvx-golden),var(--hvx-slate));border-radius:16px;padding:16px 16px 14px;color:#fff;margin-bottom:14px;}\n    .hvx-eyebrow{font-size:12px;letter-spacing:.12em;text-transform:uppercase;opacity:.9;margin:0 0 6px;}\n    .hvx-title{font-family:\"Anton\",Impact,Haettenschweiler,\"Arial Narrow Bold\",sans-serif;font-size:26px;line-height:1.05;margin:0;}\n    .hvx-desc-card{background:var(--hvx-card-bg);border:1px solid var(--hvx-border);border-radius:16px;padding:14px;margin:12px 0;box-shadow:0 10px 18px rgba(0,0,0,.06);}\n    .hvx-section-title{margin:0 0 10px;font-size:13px;letter-spacing:.12em;text-transform:uppercase;display:inline-block;padding-bottom:6px;position:relative;}\n    .hvx-section-title:after{content:\"\";position:absolute;left:0;bottom:0;height:3px;width:100%;border-radius:99px;background:linear-gradient(90deg,var(--hvx-golden),var(--hvx-slate));}\n    .hvx-badges{display:flex;flex-wrap:wrap;gap:8px;margin:6px 0 10px;}\n    .hvx-badge{display:inline-flex;align-items:center;gap:6px;padding:6px 10px;border-radius:999px;border:1px solid var(--hvx-border);background:#fff;font-size:12px;font-weight:600;}\n    .hvx-grid{display:grid;grid-template-columns:repeat(3,minmax(0,1fr));gap:10px;}\n    .hvx-kv{border:1px solid var(--hvx-border);border-radius:14px;padding:10px;background:#fff;}\n    .hvx-k{font-size:12px;letter-spacing:.08em;text-transform:uppercase;color:#333;margin:0 0 6px;}\n    .hvx-v{font-size:14px;font-weight:700;margin:0;}\n    .hvx-table-wrap{overflow:auto;border-radius:14px;border:1px solid var(--hvx-border);background:#fff;}\n    table.hvx-table{width:100%;border-collapse:collapse;min-width:520px;}\n    .hvx-table th,.hvx-table td{padding:10px 12px;border-bottom:1px solid var(--hvx-border);vertical-align:top;font-size:14px;}\n    .hvx-table th{background:rgba(250,168,25,.12);text-align:left;font-size:12px;letter-spacing:.1em;text-transform:uppercase;}\n    .hvx-table tr:last-child td{border-bottom:none;}\n    .hvx-link{color:#111;text-decoration:none;border-bottom:2px solid rgba(250,168,25,.7);}\n    .hvx-link:hover{border-bottom-color:#111;}\n    .hvx-faq details{border:1px solid var(--hvx-border);border-radius:14px;background:#fff;padding:10px 12px;margin:10px 0;}\n    .hvx-faq summary{cursor:pointer;font-weight:800;}\n    .hvx-muted{color:#333;margin:6px 0 0;}\n    @media (max-width:720px){.hvx-grid{grid-template-columns:1fr;}.hvx-title{font-size:24px;}}\n  \u003c\/style\u003e\n\u003cdiv class=\"hvx-desc\"\u003e\n\u003cdiv class=\"hvx-desc-header\"\u003e\n\u003cp class=\"hvx-eyebrow\"\u003eUniversal Floor\/Ceiling + Hyper Outdoor • R454B • 208–230V\u003c\/p\u003e\n\u003ch2 class=\"hvx-title\"\u003eCooper\u0026amp;Hunter 24,000 BTU Hyper Single Zone Universal Floor\/Ceiling Minisplit Heat Pump System R454B 230V\u003c\/h2\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"hvx-desc-card\"\u003e\n\u003ch3 class=\"hvx-section-title\"\u003eOverview\u003c\/h3\u003e\n\u003cp class=\"hvx-muted\"\u003eThis system pairs the CH-RSH24MFC Universal Floor\/Ceiling indoor unit with the CH-RHP24-230VO Hyper single-zone outdoor unit. The indoor unit supports horizontal ceiling or vertical wall installation for layout flexibility, plus built-in smart control capability, humidity sensing, and refrigerant sensing. The Hyper outdoor unit adds cold-climate heating performance with heating ambient operation listed down to -22°F.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"hvx-desc-card\"\u003e\n\u003ch3 class=\"hvx-section-title\"\u003eHighlights\u003c\/h3\u003e\n\u003cdiv class=\"hvx-badges\"\u003e\n\u003cspan class=\"hvx-badge\"\u003eR454B Refrigerant\u003c\/span\u003e \u003cspan class=\"hvx-badge\"\u003eFloor or Ceiling Install\u003c\/span\u003e \u003cspan class=\"hvx-badge\"\u003eHyper Heating to -22°F\u003c\/span\u003e \u003cspan class=\"hvx-badge\"\u003eHumidity + Refrigerant Sensors\u003c\/span\u003e \u003cspan class=\"hvx-badge\"\u003eSmart Kit + Remote + Wall Thermostat\u003c\/span\u003e \u003cspan class=\"hvx-badge\"\u003e3\/8\" \/ 5\/8\" Line Set\u003c\/span\u003e \u003cspan class=\"hvx-badge\"\u003eUp to 21.1 SEER2 (Indoor)\u003c\/span\u003e\n\u003c\/div\u003e\n\u003cul class=\"hvx-muted\" style=\"margin: 0 0 12px; padding-left: 18px;\"\u003e\n\u003cli\u003eUniversal mounting options: ceiling-suspended or wall-mounted orientation to fit the space.\u003c\/li\u003e\n\u003cli\u003eSmart control support via built-in smart kit and app connectivity (setup required).\u003c\/li\u003e\n\u003cli\u003eInverter-driven outdoor operation for steady comfort and efficient performance.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cdiv class=\"hvx-grid\"\u003e\n\u003cdiv class=\"hvx-kv\"\u003e\n\u003cp class=\"hvx-k\"\u003eSystem Search\u003c\/p\u003e\n\u003cp class=\"hvx-v\"\u003e\u003ca class=\"hvx-link\" href=\"https:\/\/hvacsupplies.com\/search?options%5Bprefix%5D=last\u0026amp;q=CH-RSH24MFC+%2B+CH-RHP24-230VO\"\u003eCH-RSH24MFC + CH-RHP24-230VO\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"hvx-kv\"\u003e\n\u003cp class=\"hvx-k\"\u003eLine Set Size\u003c\/p\u003e\n\u003cp class=\"hvx-v\"\u003e3\/8\" Liquid • 5\/8\" Gas\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"hvx-kv\"\u003e\n\u003cp class=\"hvx-k\"\u003eMax Line Length\u003c\/p\u003e\n\u003cp class=\"hvx-v\"\u003e164 ft\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"hvx-kv\"\u003e\n\u003cp class=\"hvx-k\"\u003eVoltage\u003c\/p\u003e\n\u003cp class=\"hvx-v\"\u003e208–230V (187–253V)\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"hvx-kv\"\u003e\n\u003cp class=\"hvx-k\"\u003eOutdoor Rated BTU\u003c\/p\u003e\n\u003cp class=\"hvx-v\"\u003e24,000\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"hvx-kv\"\u003e\n\u003cp class=\"hvx-k\"\u003eOutdoor AHRI\u003c\/p\u003e\n\u003cp class=\"hvx-v\"\u003e207742320\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"hvx-desc-card\"\u003e\n\u003ch3 class=\"hvx-section-title\"\u003eWhat’s Included\u003c\/h3\u003e\n\u003cul class=\"hvx-muted\" style=\"margin: 0; padding-left: 18px;\"\u003e\n\u003cli\u003eUniversal floor\/ceiling indoor unit: \u003ca class=\"hvx-link\" href=\"https:\/\/hvacsupplies.com\/search?options%5Bprefix%5D=last\u0026amp;q=CH-RSH24MFC\"\u003eCH-RSH24MFC\u003c\/a\u003e\n\u003c\/li\u003e\n\u003cli\u003eHyper outdoor condenser: \u003ca class=\"hvx-link\" href=\"https:\/\/hvacsupplies.com\/search?options%5Bprefix%5D=last\u0026amp;q=CH-RHP24-230VO\"\u003eCH-RHP24-230VO\u003c\/a\u003e\n\u003c\/li\u003e\n\u003cli\u003eIncluded remote control + wall thermostat support\u003c\/li\u003e\n\u003cli\u003eBuilt-in smart kit capability for app control (setup required)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"hvx-desc-card\"\u003e\n\u003ch3 class=\"hvx-section-title\"\u003eIndoor Specs (CH-RSH24MFC)\u003c\/h3\u003e\n\u003cdiv class=\"hvx-table-wrap\"\u003e\n\u003ctable class=\"hvx-table\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eSpec\u003c\/th\u003e\n\u003cth\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated V-Ph-Hz\u003c\/td\u003e\n\u003ctd\u003e208\/230 • 1 • 60\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCooling \/ Heating\u003c\/td\u003e\n\u003ctd\u003e24,000 \/ 24,000 BTU\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMinimum Circuit Ampacity (MCA)\u003c\/td\u003e\n\u003ctd\u003e2.5A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax Fuse\u003c\/td\u003e\n\u003ctd\u003e15A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIndoor Air Flow (Turbo\/Hi\/Mi\/Lo\/Si)\u003c\/td\u003e\n\u003ctd\u003e735.8 \/ 706.5 \/ 605.3 \/ 452.5 \/ 376.7 CFM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIndoor Noise (Turbo\/Hi\/Mi\/Lo\/Si)\u003c\/td\u003e\n\u003ctd\u003e51.5 \/ 49.5 \/ 45 \/ 34 \/ 29 dB(A)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions (W×D×H)\u003c\/td\u003e\n\u003ctd\u003e42.0 × 26.5 × 7.9 in\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePacking (W×D×H)\u003c\/td\u003e\n\u003ctd\u003e45.0 × 29.7 × 12.5 in\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNet \/ Gross Weight\u003c\/td\u003e\n\u003ctd\u003e61.29 \/ 73.19 lb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Range\u003c\/td\u003e\n\u003ctd\u003eCooling: 60–90°F • Heating: 32–86°F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLine Set\u003c\/td\u003e\n\u003ctd\u003e3\/8\" Liquid • 5\/8\" Gas\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"hvx-desc-card\"\u003e\n\u003ch3 class=\"hvx-section-title\"\u003eOutdoor Specs (CH-RHP24-230VO)\u003c\/h3\u003e\n\u003cdiv class=\"hvx-table-wrap\"\u003e\n\u003ctable class=\"hvx-table\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eSpec\u003c\/th\u003e\n\u003cth\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRefrigerant Type\u003c\/td\u003e\n\u003ctd\u003eR454B\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated BTU\u003c\/td\u003e\n\u003ctd\u003e24,000\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCooling Capacity (Min\/Max)\u003c\/td\u003e\n\u003ctd\u003e24,000 (12,600–27,900) BTU\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHeating Capacity (Min\/Max)\u003c\/td\u003e\n\u003ctd\u003e29,000 (11,800–29,700) BTU\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHSPF2 (Region V \/ IV)\u003c\/td\u003e\n\u003ctd\u003e9.8 \/ 13.5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAmbient Temperature\u003c\/td\u003e\n\u003ctd\u003eCooling: -22–122°F • Heating: -22–75°F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax Pipe Length \/ Height Difference\u003c\/td\u003e\n\u003ctd\u003e164 ft \/ 82 ft\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions (W×D×H)\u003c\/td\u003e\n\u003ctd\u003e37.24 × 16.14 × 31.89 in\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNet \/ Gross Weight\u003c\/td\u003e\n\u003ctd\u003e130.29 \/ 141.31 lb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMCA \/ Max Fuse\u003c\/td\u003e\n\u003ctd\u003e24.9A \/ 25A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutdoor Noise\u003c\/td\u003e\n\u003ctd\u003e61.5 dB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAHRI\u003c\/td\u003e\n\u003ctd\u003e207742320\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"hvx-desc-card\"\u003e\n\u003ch3 class=\"hvx-section-title\"\u003eDocuments \u0026amp; Downloads\u003c\/h3\u003e\n\u003cul class=\"hvx-muted\" style=\"margin: 0; padding-left: 18px;\"\u003e\n\u003cli\u003e\n\u003cstrong\u003eSystem Submittal (This Combination)\u003c\/strong\u003e: \u003ca class=\"hvx-link\" href=\"https:\/\/media.cooperandhunter.us\/4631\/CH-RHP24-230VO_CH-RSH24MFC.pdf\"\u003eCH-RHP24-230VO + CH-RSH24MFC\u003c\/a\u003e\n\u003c\/li\u003e\n\u003cli style=\"margin-top: 10px;\"\u003e\u003cstrong\u003eOutdoor Manuals\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca class=\"hvx-link\" href=\"https:\/\/media.cooperandhunter.us\/4118\/Installation-Manual-R454B-Outdoor-units--.pdf\"\u003eInstallation Manual — R454B Outdoor Units\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/media.cooperandhunter.us\/4291\/Floor-Ceiling-Leaflet-2025.pdf\"\u003eUFC Leaflet (R454B)\u003c\/a\u003e\u003cbr\u003e\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli style=\"font-weight: bold;\"\u003e\u003cstrong\u003eIndoor Manuals\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/media.cooperandhunter.us\/4289\/Installation-manual-LCFC.pdf\" rel=\"noopener\" target=\"_blank\"\u003eInstallation Manual\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca rel=\"noopener\" href=\"https:\/\/media.cooperandhunter.us\/4291\/Floor-Ceiling-Leaflet-2025.pdf\" target=\"_blank\"\u003eUFC Leaflet (R454B)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/media.cooperandhunter.us\/4290\/Owners-manul-UFC_R454B.pdf\" rel=\"noopener\" target=\"_blank\"\u003eOwners Manual\u003c\/a\u003e\u003c\/li\u003e\n\u003cli style=\"margin-top: 10px;\"\u003e\u003cstrong\u003eOutdoor Submittals (CH-RHP24-230VO)\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca class=\"hvx-link\" href=\"https:\/\/media.cooperandhunter.us\/3959\/CH-RHP24-230VO-%2B-CH-RS24MAHU.pdf\"\u003eCH-RHP24-230VO + CH-RS24MAHU\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca class=\"hvx-link\" href=\"https:\/\/media.cooperandhunter.us\/4160\/CH-RHP24-230VO-%2B-CH-PRO24MASTWM-230VI.pdf\"\u003eCH-RHP24-230VO + CH-PRO24MASTWM-230VI\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca class=\"hvx-link\" href=\"https:\/\/media.cooperandhunter.us\/4174\/CH-RHP24-230VO-%2B-CH-RH24MASTWM-230VI.pdf\"\u003eCH-RHP24-230VO + CH-RH24MASTWM-230VI\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca class=\"hvx-link\" href=\"https:\/\/media.cooperandhunter.us\/4205\/CH-RHP24-230VO-%2B-CH-RS24MDT-HS.pdf\"\u003eCH-RHP24-230VO + CH-RS24MDT-HS\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca class=\"hvx-link\" href=\"https:\/\/media.cooperandhunter.us\/4688\/CH-RHP24-230VO_CH-RH24MCT.pdf\"\u003eCH-RHP24-230VO + CH-RH24MCT\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"hvx-desc-card\"\u003e\n\u003ch3 class=\"hvx-section-title\"\u003eImportant\u003c\/h3\u003e\n\u003cul class=\"hvx-muted\" style=\"margin: 0; padding-left: 18px;\"\u003e\n\u003cli\u003eUse the specified line set size: 3\/8\" liquid and 5\/8\" suction (gas).\u003c\/li\u003e\n\u003cli\u003eConfirm circuit sizing and breaker\/fuse selection per MCA and local code.\u003c\/li\u003e\n\u003cli\u003eSupport: \u003ca class=\"hvx-link\" href=\"https:\/\/hvacsupplies.com\/pages\/contact\"\u003ehvacsupplies.com\/pages\/contact\u003c\/a\u003e • \u003ca class=\"hvx-link\" href=\"tel:+18005438933\"\u003e(800) 543-8933\u003c\/a\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"hvx-desc-card hvx-faq\"\u003e\n\u003ch3 class=\"hvx-section-title\"\u003eFAQs\u003c\/h3\u003e\n\u003cdetails\u003e\n\u003csummary\u003eCan the indoor unit be installed on the ceiling or wall?\u003c\/summary\u003e\n\u003cp class=\"hvx-muted\"\u003eYes. The CH-RSH24MFC supports ceiling (horizontal) or wall (vertical) installation.\u003c\/p\u003e\n\u003c\/details\u003e\n\u003cdetails\u003e\n\u003csummary\u003eHow cold can this Hyper system heat?\u003c\/summary\u003e\n\u003cp class=\"hvx-muted\"\u003eThe outdoor unit’s heating ambient range is listed to -22°F.\u003c\/p\u003e\n\u003c\/details\u003e\n\u003cdetails\u003e\n\u003csummary\u003eWhat line set size does this 24K system use?\u003c\/summary\u003e\n\u003cp class=\"hvx-muted\"\u003eThis pairing uses a 3\/8\" liquid line and a 5\/8\" gas (suction) line.\u003c\/p\u003e\n\u003c\/details\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e","brand":"Cooper\u0026Hunter","offers":[{"title":"No installation","offer_id":42695060488235,"sku":"CH-RSH24MFC + CH-RES24-230VO","price":2352.0,"currency_code":"USD","in_stock":true},{"title":"16FT","offer_id":42695060521003,"sku":"CH-RSH24MFC + CH-RES24-230VO","price":2568.0,"currency_code":"USD","in_stock":true},{"title":"25FT","offer_id":42695060553771,"sku":"CH-RSH24MFC + CH-RES24-230VO","price":2697.0,"currency_code":"USD","in_stock":true},{"title":"50FT","offer_id":42695060586539,"sku":"CH-RSH24MFC + CH-RES24-230VO","price":3004.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0625\/5647\/1339\/files\/UniversalFloorCeiling_Hyper_Product_Hero_36_75d9187f-f215-4f64-b11a-17e8dc60ffc3.png?v=1769196751"},{"product_id":"cooper-hunter-36-000-btu-hyper-single-zone-universal-floor-ceiling-minisplit-heat-pump-system-r454b-230v","title":"Cooper\u0026Hunter 36,000 BTU Hyper Single Zone Universal Floor\/Ceiling Minisplit Heat Pump System R454B 230V","description":"\u003c!-- SYSTEM 1: CH-RSH36LCFC + CH-RHP36LCU-230VO (HYPER) --\u003e\n\u003cstyle\u003e\n    :root{--hvx-golden:#FAA819;--hvx-slate:#262626;--hvx-ivory:#F4F1E6;--hvx-border:#e2e0d5;--hvx-card-bg:#ffffff;}\n    .hvx-desc{background:var(--hvx-ivory);padding:18px;border-radius:18px;font-family:\"Articulat CF\",system-ui,-apple-system,Segoe UI,Roboto,Arial,sans-serif;color:#111;}\n    .hvx-desc-header{background:linear-gradient(120deg,var(--hvx-golden),var(--hvx-slate));border-radius:16px;padding:16px 16px 14px;color:#fff;margin-bottom:14px;}\n    .hvx-eyebrow{font-size:12px;letter-spacing:.12em;text-transform:uppercase;opacity:.9;margin:0 0 6px;}\n    .hvx-title{font-family:\"Anton\",Impact,Haettenschweiler,\"Arial Narrow Bold\",sans-serif;font-size:26px;line-height:1.05;margin:0;}\n    .hvx-desc-card{background:var(--hvx-card-bg);border:1px solid var(--hvx-border);border-radius:16px;padding:14px;margin:12px 0;box-shadow:0 10px 18px rgba(0,0,0,.06);}\n    .hvx-section-title{margin:0 0 10px;font-size:13px;letter-spacing:.12em;text-transform:uppercase;display:inline-block;padding-bottom:6px;position:relative;}\n    .hvx-section-title:after{content:\"\";position:absolute;left:0;bottom:0;height:3px;width:100%;border-radius:99px;background:linear-gradient(90deg,var(--hvx-golden),var(--hvx-slate));}\n    .hvx-badges{display:flex;flex-wrap:wrap;gap:8px;margin:6px 0 10px;}\n    .hvx-badge{display:inline-flex;align-items:center;gap:6px;padding:6px 10px;border-radius:999px;border:1px solid var(--hvx-border);background:#fff;font-size:12px;font-weight:600;}\n    .hvx-grid{display:grid;grid-template-columns:repeat(3,minmax(0,1fr));gap:10px;}\n    .hvx-kv{border:1px solid var(--hvx-border);border-radius:14px;padding:10px;background:#fff;}\n    .hvx-k{font-size:12px;letter-spacing:.08em;text-transform:uppercase;color:#333;margin:0 0 6px;}\n    .hvx-v{font-size:14px;font-weight:700;margin:0;}\n    .hvx-table-wrap{overflow:auto;border-radius:14px;border:1px solid var(--hvx-border);background:#fff;}\n    table.hvx-table{width:100%;border-collapse:collapse;min-width:520px;}\n    .hvx-table th,.hvx-table td{padding:10px 12px;border-bottom:1px solid var(--hvx-border);vertical-align:top;font-size:14px;}\n    .hvx-table th{background:rgba(250,168,25,.12);text-align:left;font-size:12px;letter-spacing:.1em;text-transform:uppercase;}\n    .hvx-table tr:last-child td{border-bottom:none;}\n    .hvx-link{color:#111;text-decoration:none;border-bottom:2px solid rgba(250,168,25,.7);}\n    .hvx-link:hover{border-bottom-color:#111;}\n    .hvx-faq details{border:1px solid var(--hvx-border);border-radius:14px;background:#fff;padding:10px 12px;margin:10px 0;}\n    .hvx-faq summary{cursor:pointer;font-weight:800;}\n    .hvx-muted{color:#333;margin:6px 0 0;}\n    @media (max-width:720px){.hvx-grid{grid-template-columns:1fr;}.hvx-title{font-size:24px;}}\n  \u003c\/style\u003e\n\u003cdiv class=\"hvx-desc\"\u003e\n\u003cdiv class=\"hvx-desc-header\"\u003e\n\u003cp class=\"hvx-eyebrow\"\u003eUniversal Floor\/Ceiling (Light Commercial) + Hyper Outdoor • R454B • 208–230V\u003c\/p\u003e\n\u003ch2 class=\"hvx-title\"\u003eCooper\u0026amp;Hunter 36,000 BTU Hyper Single Zone Universal Floor\/Ceiling Minisplit Heat Pump System R454B 230V\u003c\/h2\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"hvx-desc-card\"\u003e\n\u003ch3 class=\"hvx-section-title\"\u003eOverview\u003c\/h3\u003e\n\u003cp class=\"hvx-muted\"\u003eThis system pairs the CH-RSH36LCFC Universal Floor\/Ceiling indoor unit (single-zone \/ light commercial) with the CH-RHP36LCU-230VO Hyper outdoor unit. The indoor unit supports horizontal ceiling or vertical wall installation, built-in smart control capability, and humidity + refrigerant sensing. The Hyper outdoor unit is built for cold-climate heating performance with a heating ambient range listed down to -22°F.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"hvx-desc-card\"\u003e\n\u003ch3 class=\"hvx-section-title\"\u003eHighlights\u003c\/h3\u003e\n\u003cdiv class=\"hvx-badges\"\u003e\n\u003cspan class=\"hvx-badge\"\u003eR454B Refrigerant\u003c\/span\u003e \u003cspan class=\"hvx-badge\"\u003eCeiling or Wall Install\u003c\/span\u003e \u003cspan class=\"hvx-badge\"\u003eLight Commercial Ready\u003c\/span\u003e \u003cspan class=\"hvx-badge\"\u003eHyper Heating to -22°F\u003c\/span\u003e \u003cspan class=\"hvx-badge\"\u003eHumidity + Refrigerant Sensors\u003c\/span\u003e \u003cspan class=\"hvx-badge\"\u003eSmart Kit + Remote + Wall Thermostat\u003c\/span\u003e \u003cspan class=\"hvx-badge\"\u003e3\/8\" \/ 3\/4\" Line Set\u003c\/span\u003e\n\u003c\/div\u003e\n\u003cul class=\"hvx-muted\" style=\"margin: 0 0 12px; padding-left: 18px;\"\u003e\n\u003cli\u003eUniversal mounting options for flexible layouts: ceiling-suspended or wall-mounted orientation.\u003c\/li\u003e\n\u003cli\u003eLong line length support for challenging installations (up to 246 ft max line length listed on outdoor unit).\u003c\/li\u003e\n\u003cli\u003eInverter-driven outdoor operation for steady temperature control and efficient performance.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cdiv class=\"hvx-grid\"\u003e\n\u003cdiv class=\"hvx-kv\"\u003e\n\u003cp class=\"hvx-k\"\u003eSystem Search\u003c\/p\u003e\n\u003cp class=\"hvx-v\"\u003e\u003ca class=\"hvx-link\" href=\"https:\/\/hvacsupplies.com\/search?options%5Bprefix%5D=last\u0026amp;q=CH-RSH36LCFC+%2B+CH-RHP36LCU-230VO\"\u003eCH-RSH36LCFC + CH-RHP36LCU-230VO\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"hvx-kv\"\u003e\n\u003cp class=\"hvx-k\"\u003eLine Set Size\u003c\/p\u003e\n\u003cp class=\"hvx-v\"\u003e3\/8\" Liquid • 3\/4\" Gas\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"hvx-kv\"\u003e\n\u003cp class=\"hvx-k\"\u003eMax Line \/ Lift\u003c\/p\u003e\n\u003cp class=\"hvx-v\"\u003e246 ft • 98.4 ft\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"hvx-kv\"\u003e\n\u003cp class=\"hvx-k\"\u003eVoltage\u003c\/p\u003e\n\u003cp class=\"hvx-v\"\u003e208–230V (187–253V)\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"hvx-kv\"\u003e\n\u003cp class=\"hvx-k\"\u003eIndoor \/ Outdoor BTU\u003c\/p\u003e\n\u003cp class=\"hvx-v\"\u003e36,000 \/ 36,000\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"hvx-kv\"\u003e\n\u003cp class=\"hvx-k\"\u003eOutdoor SEER2\u003c\/p\u003e\n\u003cp class=\"hvx-v\"\u003e20\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"hvx-desc-card\"\u003e\n\u003ch3 class=\"hvx-section-title\"\u003eWhat’s Included\u003c\/h3\u003e\n\u003cul class=\"hvx-muted\" style=\"margin: 0; padding-left: 18px;\"\u003e\n\u003cli\u003eUniversal floor\/ceiling indoor unit: \u003ca class=\"hvx-link\" href=\"https:\/\/hvacsupplies.com\/search?options%5Bprefix%5D=last\u0026amp;q=CH-RSH36LCFC\"\u003eCH-RSH36LCFC\u003c\/a\u003e\n\u003c\/li\u003e\n\u003cli\u003eHyper outdoor condenser: \u003ca class=\"hvx-link\" href=\"https:\/\/hvacsupplies.com\/search?options%5Bprefix%5D=last\u0026amp;q=CH-RHP36LCU-230VO\"\u003eCH-RHP36LCU-230VO\u003c\/a\u003e\n\u003c\/li\u003e\n\u003cli\u003eRemote control + wall thermostat support\u003c\/li\u003e\n\u003cli\u003eBuilt-in smart kit capability for app control (setup required)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"hvx-desc-card\"\u003e\n\u003ch3 class=\"hvx-section-title\"\u003eIndoor Specs (CH-RSH36LCFC)\u003c\/h3\u003e\n\u003cdiv class=\"hvx-table-wrap\"\u003e\n\u003ctable class=\"hvx-table\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eSpec\u003c\/th\u003e\n\u003cth\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRefrigerant Type\u003c\/td\u003e\n\u003ctd\u003eR454B\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated BTU\u003c\/td\u003e\n\u003ctd\u003e36,000\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower\u003c\/td\u003e\n\u003ctd\u003e208–230V, 1Ph, 60Hz (187–253V)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSEER2 \/ EER2\u003c\/td\u003e\n\u003ctd\u003e20 \/ 12\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDehumidification\u003c\/td\u003e\n\u003ctd\u003e6.55 pints\/day\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRefrigerant Piping\u003c\/td\u003e\n\u003ctd\u003e3\/8\" Liquid • 3\/4\" Gas\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIndoor Air Flow\u003c\/td\u003e\n\u003ctd\u003e1,224.3 \/ 1,088.9 \/ 988.8 \/ 765.2 CFM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIndoor Noise (H\/M\/L)\u003c\/td\u003e\n\u003ctd\u003e51 \/ 45.5 \/ 39 dB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions (W×H×D)\u003c\/td\u003e\n\u003ctd\u003e64.96 × 26.57 × 9.25 in\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePacking (W×D×H)\u003c\/td\u003e\n\u003ctd\u003e67.91 × 29.72 × 12.52 in\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNet \/ Gross Weight\u003c\/td\u003e\n\u003ctd\u003e88.85 \/ 104.94 lb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Range\u003c\/td\u003e\n\u003ctd\u003eCooling: 60–90°F • Heating: 32–86°F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMCA \/ Max Fuse\u003c\/td\u003e\n\u003ctd\u003e3A \/ 15A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDrain Pipe\u003c\/td\u003e\n\u003ctd\u003e1\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"hvx-desc-card\"\u003e\n\u003ch3 class=\"hvx-section-title\"\u003eOutdoor Specs (CH-RHP36LCU-230VO)\u003c\/h3\u003e\n\u003cdiv class=\"hvx-table-wrap\"\u003e\n\u003ctable class=\"hvx-table\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eSpec\u003c\/th\u003e\n\u003cth\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRefrigerant Type\u003c\/td\u003e\n\u003ctd\u003eR454B\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated BTU\u003c\/td\u003e\n\u003ctd\u003e36,000\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSEER2 \/ EER2\u003c\/td\u003e\n\u003ctd\u003e17.7 \/ 12\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCooling Capacity (Min\/Max)\u003c\/td\u003e\n\u003ctd\u003e36,000 (9,800–37,000) BTU\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHeating Capacity (Min\/Max)\u003c\/td\u003e\n\u003ctd\u003e42,000 (11,000–45,500) BTU\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHSPF2 (Region V \/ IV)\u003c\/td\u003e\n\u003ctd\u003e9.2 \/ 11.1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAmbient Temperature\u003c\/td\u003e\n\u003ctd\u003eCooling: -22–122°F • Heating: -22–75°F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax Pipe Length \/ Height Difference\u003c\/td\u003e\n\u003ctd\u003e246 ft \/ 98.4 ft\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions (W×D×H)\u003c\/td\u003e\n\u003ctd\u003e38.58 × 16.34 × 38.39 in\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNet \/ Gross Weight\u003c\/td\u003e\n\u003ctd\u003e206.57 \/ 237.44 lb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMCA \/ Max Fuse\u003c\/td\u003e\n\u003ctd\u003e38A \/ 40A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutdoor Noise\u003c\/td\u003e\n\u003ctd\u003e65 dB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"hvx-desc-card\"\u003e\n\u003ch3 class=\"hvx-section-title\"\u003eDocuments \u0026amp; Downloads\u003c\/h3\u003e\n\u003cul class=\"hvx-muted\" style=\"margin: 0; padding-left: 18px;\"\u003e\n\u003cli\u003e\n\u003cstrong\u003eSystem Submittal (This Combination)\u003c\/strong\u003e: \u003ca class=\"hvx-link\" href=\"https:\/\/media.cooperandhunter.us\/4632\/CH-RHP36LCU-230VO_CH-RSH36LCFC.pdf\"\u003eCH-RHP36LCU-230VO + CH-RSH36LCFC\u003c\/a\u003e\n\u003c\/li\u003e\n\u003cli style=\"margin-top: 10px;\"\u003e\u003cstrong\u003eIndoor Manuals\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca class=\"hvx-link\" href=\"https:\/\/media.cooperandhunter.us\/4289\/Installation-manual-LCFC.pdf\"\u003eInstallation Manual — LCFC\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca class=\"hvx-link\" href=\"https:\/\/media.cooperandhunter.us\/4290\/Owners-manul-UFC_R454B.pdf\"\u003eOwner’s Manual — UFC (R454B)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca class=\"hvx-link\" href=\"https:\/\/media.cooperandhunter.us\/4291\/Floor-Ceiling-Leaflet-2025.pdf\"\u003eFloor\/Ceiling Leaflet (2025)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli style=\"margin-top: 10px;\"\u003e\u003cstrong\u003eIndoor Reference Docs\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca class=\"hvx-link\" href=\"https:\/\/media.cooperandhunter.us\/3198\/MultiZone-Combination-HYPER.pdf\"\u003eMulti-Zone Combination — Hyper\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca class=\"hvx-link\" href=\"https:\/\/media.cooperandhunter.us\/3199\/MultiZone-Combination-Regular.pdf\"\u003eMulti-Zone Combination — Regular\u003c\/a\u003e\u003c\/li\u003e\n\u003cli style=\"margin-top: 10px;\"\u003e\u003cstrong\u003eOutdoor Manuals\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca class=\"hvx-link\" href=\"https:\/\/media.cooperandhunter.us\/4200\/SlimDuct-Leaflet-R454B.pdf\"\u003eSlimDuct Leaflet (R454B)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli style=\"margin-top: 10px;\"\u003e\u003cstrong\u003eOutdoor Submittals (CH-RHP36LCU-230VO)\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca class=\"hvx-link\" href=\"https:\/\/media.cooperandhunter.us\/3960\/CH-RHP36LCU-230VO-%2B-CH-RS36LCAHU.pdf\"\u003eCH-RHP36LCU-230VO + CH-RS36LCAHU\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca class=\"hvx-link\" href=\"https:\/\/media.cooperandhunter.us\/4206\/CH-RHP36LCU-230VO-%2B-CH-RS36LCDT-HS.pdf\"\u003eCH-RHP36LCU-230VO + CH-RS36LCDT-HS\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca class=\"hvx-link\" href=\"https:\/\/media.cooperandhunter.us\/4693\/CH-RHP36LCU-230VO_CH-RH36LCCT.pdf\"\u003eCH-RHP36LCU-230VO + CH-RH36LCCT\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca class=\"hvx-link\" href=\"https:\/\/media.cooperandhunter.us\/4694\/CH-RHP36LCU-230VO_CH-RSH36LCCT.pdf\"\u003eCH-RHP36LCU-230VO + CH-RSH36LCCT\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"hvx-desc-card\"\u003e\n\u003ch3 class=\"hvx-section-title\"\u003eImportant\u003c\/h3\u003e\n\u003cul class=\"hvx-muted\" style=\"margin: 0; padding-left: 18px;\"\u003e\n\u003cli\u003eLine set size for this pairing: 3\/8\" liquid and 3\/4\" suction (gas).\u003c\/li\u003e\n\u003cli\u003eConfirm circuit sizing and overcurrent protection per outdoor MCA and local code requirements.\u003c\/li\u003e\n\u003cli\u003eSupport: \u003ca class=\"hvx-link\" href=\"https:\/\/hvacsupplies.com\/pages\/contact\"\u003ehvacsupplies.com\/pages\/contact\u003c\/a\u003e • \u003ca class=\"hvx-link\" href=\"tel:+18005438933\"\u003e(800) 543-8933\u003c\/a\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"hvx-desc-card hvx-faq\"\u003e\n\u003ch3 class=\"hvx-section-title\"\u003eFAQs\u003c\/h3\u003e\n\u003cdetails\u003e\n\u003csummary\u003eCan the indoor unit be installed on the ceiling or wall?\u003c\/summary\u003e\n\u003cp class=\"hvx-muted\"\u003eYes. The CH-RSH36LCFC supports ceiling (horizontal) or wall (vertical) installation.\u003c\/p\u003e\n\u003c\/details\u003e\n\u003cdetails\u003e\n\u003csummary\u003eHow cold can this Hyper system heat?\u003c\/summary\u003e\n\u003cp class=\"hvx-muted\"\u003eThe Hyper outdoor unit’s heating ambient range is listed down to -22°F.\u003c\/p\u003e\n\u003c\/details\u003e\n\u003cdetails\u003e\n\u003csummary\u003eWhat line set size does this 36K LC floor\/ceiling system use?\u003c\/summary\u003e\n\u003cp class=\"hvx-muted\"\u003eThis pairing uses a 3\/8\" liquid line and a 3\/4\" gas (suction) line.\u003c\/p\u003e\n\u003c\/details\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e","brand":"Cooper\u0026Hunter","offers":[{"title":"No installation","offer_id":42695082541099,"sku":"CH-RSH36LCFC + CH-RHP36LCU-230VO","price":4953.0,"currency_code":"USD","in_stock":true},{"title":"25FT","offer_id":42695082606635,"sku":"CH-RSH36LCFC + CH-RHP36LCU-230VO","price":5434.0,"currency_code":"USD","in_stock":true},{"title":"50FT","offer_id":42695082639403,"sku":"CH-RSH36LCFC + CH-RHP36LCU-230VO","price":5627.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0625\/5647\/1339\/files\/2-Zone_Ductless_Mini_Split_AC_Heat_Pump_48000_BTU_21.png?v=1769196773"},{"product_id":"cooper-hunter-36-000-btu-single-zone-universal-floor-ceiling-minisplit-heat-pump-system-r454b-230v","title":"Cooper\u0026Hunter 36,000 BTU Single Zone Universal Floor\/Ceiling Minisplit Heat Pump System R454B 230V","description":"\u003c!-- SYSTEM 2: CH-RSH36LCFC + CH-R36LCU-230VO (REGULAR) --\u003e\n\u003cstyle\u003e\n    :root{--hvx-golden:#FAA819;--hvx-slate:#262626;--hvx-ivory:#F4F1E6;--hvx-border:#e2e0d5;--hvx-card-bg:#ffffff;}\n    .hvx-desc{background:var(--hvx-ivory);padding:18px;border-radius:18px;font-family:\"Articulat CF\",system-ui,-apple-system,Segoe UI,Roboto,Arial,sans-serif;color:#111;}\n    .hvx-desc-header{background:linear-gradient(120deg,var(--hvx-golden),var(--hvx-slate));border-radius:16px;padding:16px 16px 14px;color:#fff;margin-bottom:14px;}\n    .hvx-eyebrow{font-size:12px;letter-spacing:.12em;text-transform:uppercase;opacity:.9;margin:0 0 6px;}\n    .hvx-title{font-family:\"Anton\",Impact,Haettenschweiler,\"Arial Narrow Bold\",sans-serif;font-size:26px;line-height:1.05;margin:0;}\n    .hvx-desc-card{background:var(--hvx-card-bg);border:1px solid var(--hvx-border);border-radius:16px;padding:14px;margin:12px 0;box-shadow:0 10px 18px rgba(0,0,0,.06);}\n    .hvx-section-title{margin:0 0 10px;font-size:13px;letter-spacing:.12em;text-transform:uppercase;display:inline-block;padding-bottom:6px;position:relative;}\n    .hvx-section-title:after{content:\"\";position:absolute;left:0;bottom:0;height:3px;width:100%;border-radius:99px;background:linear-gradient(90deg,var(--hvx-golden),var(--hvx-slate));}\n    .hvx-badges{display:flex;flex-wrap:wrap;gap:8px;margin:6px 0 10px;}\n    .hvx-badge{display:inline-flex;align-items:center;gap:6px;padding:6px 10px;border-radius:999px;border:1px solid var(--hvx-border);background:#fff;font-size:12px;font-weight:600;}\n    .hvx-grid{display:grid;grid-template-columns:repeat(3,minmax(0,1fr));gap:10px;}\n    .hvx-kv{border:1px solid var(--hvx-border);border-radius:14px;padding:10px;background:#fff;}\n    .hvx-k{font-size:12px;letter-spacing:.08em;text-transform:uppercase;color:#333;margin:0 0 6px;}\n    .hvx-v{font-size:14px;font-weight:700;margin:0;}\n    .hvx-table-wrap{overflow:auto;border-radius:14px;border:1px solid var(--hvx-border);background:#fff;}\n    table.hvx-table{width:100%;border-collapse:collapse;min-width:520px;}\n    .hvx-table th,.hvx-table td{padding:10px 12px;border-bottom:1px solid var(--hvx-border);vertical-align:top;font-size:14px;}\n    .hvx-table th{background:rgba(250,168,25,.12);text-align:left;font-size:12px;letter-spacing:.1em;text-transform:uppercase;}\n    .hvx-table tr:last-child td{border-bottom:none;}\n    .hvx-link{color:#111;text-decoration:none;border-bottom:2px solid rgba(250,168,25,.7);}\n    .hvx-link:hover{border-bottom-color:#111;}\n    .hvx-faq details{border:1px solid var(--hvx-border);border-radius:14px;background:#fff;padding:10px 12px;margin:10px 0;}\n    .hvx-faq summary{cursor:pointer;font-weight:800;}\n    .hvx-muted{color:#333;margin:6px 0 0;}\n    @media (max-width:720px){.hvx-grid{grid-template-columns:1fr;}.hvx-title{font-size:24px;}}\n  \u003c\/style\u003e\n\u003cdiv class=\"hvx-desc\"\u003e\n\u003cdiv class=\"hvx-desc-header\"\u003e\n\u003cp class=\"hvx-eyebrow\"\u003eUniversal Floor\/Ceiling (Light Commercial) + Regular Outdoor • R454B • 208–230V\u003c\/p\u003e\n\u003ch2 class=\"hvx-title\"\u003eCooper\u0026amp;Hunter 36,000 BTU Single Zone Universal Floor\/Ceiling Minisplit Heat Pump System R454B 230V=\u003c\/h2\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"hvx-desc-card\"\u003e\n\u003ch3 class=\"hvx-section-title\"\u003eOverview\u003c\/h3\u003e\n\u003cp class=\"hvx-muted\"\u003eThis system pairs the CH-RSH36LCFC Universal Floor\/Ceiling indoor unit (single-zone \/ light commercial) with the CH-R36LCU-230VO Regular outdoor unit. The indoor unit supports horizontal ceiling or vertical wall installation, built-in smart control capability, and humidity + refrigerant sensing. The Regular outdoor unit provides inverter heating and cooling with a heating ambient range listed to -13°F.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"hvx-desc-card\"\u003e\n\u003ch3 class=\"hvx-section-title\"\u003eHighlights\u003c\/h3\u003e\n\u003cdiv class=\"hvx-badges\"\u003e\n\u003cspan class=\"hvx-badge\"\u003eR454B Refrigerant\u003c\/span\u003e \u003cspan class=\"hvx-badge\"\u003eCeiling or Wall Install\u003c\/span\u003e \u003cspan class=\"hvx-badge\"\u003eLight Commercial Ready\u003c\/span\u003e \u003cspan class=\"hvx-badge\"\u003eInverter Comfort Control\u003c\/span\u003e \u003cspan class=\"hvx-badge\"\u003eHumidity + Refrigerant Sensors\u003c\/span\u003e \u003cspan class=\"hvx-badge\"\u003eSmart Kit + Remote + Wall Thermostat\u003c\/span\u003e \u003cspan class=\"hvx-badge\"\u003e3\/8\" \/ 3\/4\" Line Set\u003c\/span\u003e\n\u003c\/div\u003e\n\u003cul style=\"margin: 0 0 12px; padding-left: 18px;\" class=\"hvx-muted\"\u003e\n\u003cli\u003eUniversal mounting options for flexible layouts: ceiling-suspended or wall-mounted orientation.\u003c\/li\u003e\n\u003cli\u003eLong line length support for challenging installations (up to 246 ft max line length listed on outdoor unit).\u003c\/li\u003e\n\u003cli\u003eEfficient inverter outdoor operation for steady comfort and day-to-day savings.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cdiv class=\"hvx-grid\"\u003e\n\u003cdiv class=\"hvx-kv\"\u003e\n\u003cp class=\"hvx-k\"\u003eSystem Search\u003c\/p\u003e\n\u003cp class=\"hvx-v\"\u003e\u003ca href=\"https:\/\/hvacsupplies.com\/search?options%5Bprefix%5D=last\u0026amp;q=CH-RSH36LCFC+%2B+CH-R36LCU-230VO\" class=\"hvx-link\"\u003eCH-RSH36LCFC + CH-R36LCU-230VO\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"hvx-kv\"\u003e\n\u003cp class=\"hvx-k\"\u003eLine Set Size\u003c\/p\u003e\n\u003cp class=\"hvx-v\"\u003e3\/8\" Liquid • 3\/4\" Gas\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"hvx-kv\"\u003e\n\u003cp class=\"hvx-k\"\u003eMax Line \/ Lift\u003c\/p\u003e\n\u003cp class=\"hvx-v\"\u003e246 ft • 98.4 ft\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"hvx-kv\"\u003e\n\u003cp class=\"hvx-k\"\u003eVoltage\u003c\/p\u003e\n\u003cp class=\"hvx-v\"\u003e208–230V (187–253V)\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"hvx-kv\"\u003e\n\u003cp class=\"hvx-k\"\u003eOutdoor AHRI\u003c\/p\u003e\n\u003cp class=\"hvx-v\"\u003e207742340\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"hvx-kv\"\u003e\n\u003cp class=\"hvx-k\"\u003eOutdoor SEER2\u003c\/p\u003e\n\u003cp class=\"hvx-v\"\u003e20\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"hvx-desc-card\"\u003e\n\u003ch3 class=\"hvx-section-title\"\u003eWhat’s Included\u003c\/h3\u003e\n\u003cul style=\"margin: 0; padding-left: 18px;\" class=\"hvx-muted\"\u003e\n\u003cli\u003eUniversal floor\/ceiling indoor unit: \u003ca href=\"https:\/\/hvacsupplies.com\/search?options%5Bprefix%5D=last\u0026amp;q=CH-RSH36LCFC\" class=\"hvx-link\"\u003eCH-RSH36LCFC\u003c\/a\u003e\n\u003c\/li\u003e\n\u003cli\u003eRegular outdoor condenser: \u003ca href=\"https:\/\/hvacsupplies.com\/search?options%5Bprefix%5D=last\u0026amp;q=CH-R36LCU-230VO\" class=\"hvx-link\"\u003eCH-R36LCU-230VO\u003c\/a\u003e\n\u003c\/li\u003e\n\u003cli\u003eRemote control + wall thermostat support\u003c\/li\u003e\n\u003cli\u003eBuilt-in smart kit capability for app control (setup required)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"hvx-desc-card\"\u003e\n\u003ch3 class=\"hvx-section-title\"\u003eIndoor Specs (CH-RSH36LCFC)\u003c\/h3\u003e\n\u003cdiv class=\"hvx-table-wrap\"\u003e\n\u003ctable class=\"hvx-table\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eSpec\u003c\/th\u003e\n\u003cth\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRefrigerant Type\u003c\/td\u003e\n\u003ctd\u003eR454B\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated BTU\u003c\/td\u003e\n\u003ctd\u003e36,000\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower\u003c\/td\u003e\n\u003ctd\u003e208–230V, 1Ph, 60Hz (187–253V)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSEER2 \/ EER2\u003c\/td\u003e\n\u003ctd\u003e20 \/ 12\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDehumidification\u003c\/td\u003e\n\u003ctd\u003e6.55 pints\/day\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRefrigerant Piping\u003c\/td\u003e\n\u003ctd\u003e3\/8\" Liquid • 3\/4\" Gas\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIndoor Air Flow\u003c\/td\u003e\n\u003ctd\u003e1,224.3 \/ 1,088.9 \/ 988.8 \/ 765.2 CFM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIndoor Noise (H\/M\/L)\u003c\/td\u003e\n\u003ctd\u003e51 \/ 45.5 \/ 39 dB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions (W×H×D)\u003c\/td\u003e\n\u003ctd\u003e64.96 × 26.57 × 9.25 in\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePacking (W×D×H)\u003c\/td\u003e\n\u003ctd\u003e67.91 × 29.72 × 12.52 in\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNet \/ Gross Weight\u003c\/td\u003e\n\u003ctd\u003e88.85 \/ 104.94 lb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Range\u003c\/td\u003e\n\u003ctd\u003eCooling: 60–90°F • Heating: 32–86°F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMCA \/ Max Fuse\u003c\/td\u003e\n\u003ctd\u003e3A \/ 15A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDrain Pipe\u003c\/td\u003e\n\u003ctd\u003e1\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"hvx-desc-card\"\u003e\n\u003ch3 class=\"hvx-section-title\"\u003eOutdoor Specs (CH-R36LCU-230VO)\u003c\/h3\u003e\n\u003cdiv class=\"hvx-table-wrap\"\u003e\n\u003ctable class=\"hvx-table\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eSpec\u003c\/th\u003e\n\u003cth\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRefrigerant Type\u003c\/td\u003e\n\u003ctd\u003eR454B\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated BTU\u003c\/td\u003e\n\u003ctd\u003e36,000\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSEER2 \/ EER2\u003c\/td\u003e\n\u003ctd\u003e18.7 \/ 10.1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCooling Capacity (Min\/Max)\u003c\/td\u003e\n\u003ctd\u003e36,000 (7,900–42,500) BTU\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHeating Capacity (Min\/Max)\u003c\/td\u003e\n\u003ctd\u003e40,000 (8,100–43,500) BTU\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHSPF2 (Region V \/ IV)\u003c\/td\u003e\n\u003ctd\u003e7.8 \/ 10.2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAmbient Temperature\u003c\/td\u003e\n\u003ctd\u003eCooling: -13–122°F • Heating: -13–75°F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax Pipe Length \/ Height Difference\u003c\/td\u003e\n\u003ctd\u003e246 ft \/ 98.4 ft\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions (W×D×H)\u003c\/td\u003e\n\u003ctd\u003e37.24 × 16.14 × 31.89 in\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNet \/ Gross Weight\u003c\/td\u003e\n\u003ctd\u003e152.34 \/ 162.48 lb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMCA \/ Max Fuse\u003c\/td\u003e\n\u003ctd\u003e33A \/ 35A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutdoor Noise\u003c\/td\u003e\n\u003ctd\u003e63 dB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAHRI\u003c\/td\u003e\n\u003ctd\u003e207742340\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"hvx-desc-card\"\u003e\n\u003ch3 class=\"hvx-section-title\"\u003eDocuments \u0026amp; Downloads\u003c\/h3\u003e\n\u003cul style=\"margin: 0; padding-left: 18px;\" class=\"hvx-muted\"\u003e\n\u003cli\u003e\n\u003cstrong\u003eSystem Submittal (This Combination)\u003c\/strong\u003e: \u003ca href=\"https:\/\/media.cooperandhunter.us\/4627\/CH-R36LCU-230VO_CH-RSH36LCFC.pdf\" class=\"hvx-link\"\u003eCH-R36LCU-230VO + CH-RSH36LCFC\u003c\/a\u003e\n\u003c\/li\u003e\n\u003cli style=\"margin-top: 10px;\"\u003e\u003cstrong\u003eIndoor Manuals\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/media.cooperandhunter.us\/4289\/Installation-manual-LCFC.pdf\" class=\"hvx-link\"\u003eInstallation Manual — LCFC\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/media.cooperandhunter.us\/4290\/Owners-manul-UFC_R454B.pdf\" class=\"hvx-link\"\u003eOwner’s Manual — UFC (R454B)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/media.cooperandhunter.us\/4291\/Floor-Ceiling-Leaflet-2025.pdf\" class=\"hvx-link\"\u003eFloor\/Ceiling Leaflet (2025)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli style=\"margin-top: 10px;\"\u003e\u003cstrong\u003eIndoor Reference Docs\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/media.cooperandhunter.us\/3198\/MultiZone-Combination-HYPER.pdf\" class=\"hvx-link\"\u003eMulti-Zone Combination — Hyper\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/media.cooperandhunter.us\/3199\/MultiZone-Combination-Regular.pdf\" class=\"hvx-link\"\u003eMulti-Zone Combination — Regular\u003c\/a\u003e\u003c\/li\u003e\n\u003cli style=\"margin-top: 10px;\"\u003e\u003cstrong\u003eOutdoor Manuals\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/media.cooperandhunter.us\/4200\/SlimDuct-Leaflet-R454B.pdf\" class=\"hvx-link\"\u003eSlimDuct Leaflet (R454B)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli style=\"margin-top: 10px;\"\u003e\u003cstrong\u003eOutdoor Submittals (CH-R36LCU-230VO)\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/media.cooperandhunter.us\/4213\/CH-R36LCU-230VO-%2B-CH-RS36LCDT-HS.pdf\" class=\"hvx-link\"\u003eCH-R36LCU-230VO + CH-RS36LCDT-HS\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/media.cooperandhunter.us\/4689\/CH-R36LCU-230VO_CH-RH36LCCT.pdf\" class=\"hvx-link\"\u003eCH-R36LCU-230VO + CH-RH36LCCT\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/media.cooperandhunter.us\/4690\/CH-R36LCU-230VO_CH-RSH36LCCT.pdf\" class=\"hvx-link\"\u003eCH-R36LCU-230VO + CH-RSH36LCCT\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"hvx-desc-card\"\u003e\n\u003ch3 class=\"hvx-section-title\"\u003eImportant\u003c\/h3\u003e\n\u003cul style=\"margin: 0; padding-left: 18px;\" class=\"hvx-muted\"\u003e\n\u003cli\u003eLine set size for this pairing: 3\/8\" liquid and 3\/4\" suction (gas).\u003c\/li\u003e\n\u003cli\u003eConfirm circuit sizing and overcurrent protection per outdoor MCA and local code requirements.\u003c\/li\u003e\n\u003cli\u003eSupport: \u003ca href=\"https:\/\/hvacsupplies.com\/pages\/contact\" class=\"hvx-link\"\u003ehvacsupplies.com\/pages\/contact\u003c\/a\u003e • \u003ca href=\"tel:+18005438933\" class=\"hvx-link\"\u003e(800) 543-8933\u003c\/a\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"hvx-desc-card hvx-faq\"\u003e\n\u003ch3 class=\"hvx-section-title\"\u003eFAQs\u003c\/h3\u003e\n\u003cdetails\u003e\n\u003csummary\u003eCan the indoor unit be installed on the ceiling or wall?\u003c\/summary\u003e\n\u003cp class=\"hvx-muted\"\u003eYes. The CH-RSH36LCFC supports ceiling (horizontal) or wall (vertical) installation.\u003c\/p\u003e\n\u003c\/details\u003e\n\u003cdetails\u003e\n\u003csummary\u003eHow cold can this Regular system heat?\u003c\/summary\u003e\n\u003cp class=\"hvx-muted\"\u003eThe Regular outdoor unit’s heating ambient range is listed to -13°F.\u003c\/p\u003e\n\u003c\/details\u003e\n\u003cdetails\u003e\n\u003csummary\u003eWhat line set size does this 36K LC floor\/ceiling system use?\u003c\/summary\u003e\n\u003cp class=\"hvx-muted\"\u003eThis pairing uses a 3\/8\" liquid line and a 3\/4\" gas (suction) line.\u003c\/p\u003e\n\u003c\/details\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e","brand":"Cooper\u0026Hunter","offers":[{"title":"No installation","offer_id":42695098761259,"sku":"CH-RSH36LCFC + CH-R36LCU-230VO","price":3565.0,"currency_code":"USD","in_stock":true},{"title":"25FT","offer_id":42695098794027,"sku":"CH-RSH36LCFC + CH-R36LCU-230VO","price":4046.0,"currency_code":"USD","in_stock":true},{"title":"50FT","offer_id":42695098826795,"sku":"CH-RSH36LCFC + CH-R36LCU-230VO","price":4239.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0625\/5647\/1339\/files\/UniversalFloorCeiling_Hyper_Product_Hero_36_75d9187f-f215-4f64-b11a-17e8dc60ffc3.png?v=1769196751"},{"product_id":"cooper-hunter-48-000-btu-hyper-single-zone-universal-floor-ceiling-minisplit-heat-pump-system-r454b-230v","title":"Cooper\u0026Hunter 48,000 BTU Hyper Single Zone Universal Floor\/Ceiling Minisplit Heat Pump System R454B 230V","description":"\u003c!-- SYSTEM 1: CH-RSH48LCFC + CH-RHP48LCU-230VO (HYPER) --\u003e\n\u003cstyle\u003e\n    :root{--hvx-golden:#FAA819;--hvx-slate:#262626;--hvx-ivory:#F4F1E6;--hvx-border:#e2e0d5;--hvx-card-bg:#ffffff;}\n    .hvx-desc{background:var(--hvx-ivory);padding:18px;border-radius:18px;font-family:\"Articulat CF\",system-ui,-apple-system,Segoe UI,Roboto,Arial,sans-serif;color:#111;}\n    .hvx-desc-header{background:linear-gradient(120deg,var(--hvx-golden),var(--hvx-slate));border-radius:16px;padding:16px 16px 14px;color:#fff;margin-bottom:14px;}\n    .hvx-eyebrow{font-size:12px;letter-spacing:.12em;text-transform:uppercase;opacity:.9;margin:0 0 6px;}\n    .hvx-title{font-family:\"Anton\",Impact,Haettenschweiler,\"Arial Narrow Bold\",sans-serif;font-size:26px;line-height:1.05;margin:0;}\n    .hvx-desc-card{background:var(--hvx-card-bg);border:1px solid var(--hvx-border);border-radius:16px;padding:14px;margin:12px 0;box-shadow:0 10px 18px rgba(0,0,0,.06);}\n    .hvx-section-title{margin:0 0 10px;font-size:13px;letter-spacing:.12em;text-transform:uppercase;display:inline-block;padding-bottom:6px;position:relative;}\n    .hvx-section-title:after{content:\"\";position:absolute;left:0;bottom:0;height:3px;width:100%;border-radius:99px;background:linear-gradient(90deg,var(--hvx-golden),var(--hvx-slate));}\n    .hvx-badges{display:flex;flex-wrap:wrap;gap:8px;margin:6px 0 10px;}\n    .hvx-badge{display:inline-flex;align-items:center;gap:6px;padding:6px 10px;border-radius:999px;border:1px solid var(--hvx-border);background:#fff;font-size:12px;font-weight:600;}\n    .hvx-grid{display:grid;grid-template-columns:repeat(3,minmax(0,1fr));gap:10px;}\n    .hvx-kv{border:1px solid var(--hvx-border);border-radius:14px;padding:10px;background:#fff;}\n    .hvx-k{font-size:12px;letter-spacing:.08em;text-transform:uppercase;color:#333;margin:0 0 6px;}\n    .hvx-v{font-size:14px;font-weight:700;margin:0;}\n    .hvx-table-wrap{overflow:auto;border-radius:14px;border:1px solid var(--hvx-border);background:#fff;}\n    table.hvx-table{width:100%;border-collapse:collapse;min-width:520px;}\n    .hvx-table th,.hvx-table td{padding:10px 12px;border-bottom:1px solid var(--hvx-border);vertical-align:top;font-size:14px;}\n    .hvx-table th{background:rgba(250,168,25,.12);text-align:left;font-size:12px;letter-spacing:.1em;text-transform:uppercase;}\n    .hvx-table tr:last-child td{border-bottom:none;}\n    .hvx-link{color:#111;text-decoration:none;border-bottom:2px solid rgba(250,168,25,.7);}\n    .hvx-link:hover{border-bottom-color:#111;}\n    .hvx-faq details{border:1px solid var(--hvx-border);border-radius:14px;background:#fff;padding:10px 12px;margin:10px 0;}\n    .hvx-faq summary{cursor:pointer;font-weight:800;}\n    .hvx-muted{color:#333;margin:6px 0 0;}\n    @media (max-width:720px){.hvx-grid{grid-template-columns:1fr;}.hvx-title{font-size:24px;}}\n  \u003c\/style\u003e\n\u003cdiv class=\"hvx-desc\"\u003e\n\u003cdiv class=\"hvx-desc-header\"\u003e\n\u003cp class=\"hvx-eyebrow\"\u003eUniversal Floor\/Ceiling (Light Commercial) + Hyper Outdoor • R454B • 208–230V\u003c\/p\u003e\n\u003ch2 class=\"hvx-title\"\u003eCooper\u0026amp;Hunter 48,000 BTU Hyper Single Zone Universal Floor\/Ceiling Minisplit Heat Pump System R454B 230V\u003c\/h2\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"hvx-desc-card\"\u003e\n\u003ch3 class=\"hvx-section-title\"\u003eOverview\u003c\/h3\u003e\n\u003cp class=\"hvx-muted\"\u003eThis system pairs the CH-RSH48LCFC Universal Floor\/Ceiling indoor unit (single-zone \/ light commercial) with the CH-RHP48LCU-230VO Hyper outdoor unit. The indoor unit supports horizontal ceiling or vertical wall installation, built-in smart control capability, and humidity + refrigerant sensing. The Hyper outdoor unit is built for cold-climate heating performance with a heating ambient range listed down to -22°F.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"hvx-desc-card\"\u003e\n\u003ch3 class=\"hvx-section-title\"\u003eHighlights\u003c\/h3\u003e\n\u003cdiv class=\"hvx-badges\"\u003e\n\u003cspan class=\"hvx-badge\"\u003eR454B Refrigerant\u003c\/span\u003e \u003cspan class=\"hvx-badge\"\u003eCeiling or Wall Install\u003c\/span\u003e \u003cspan class=\"hvx-badge\"\u003eLight Commercial Ready\u003c\/span\u003e \u003cspan class=\"hvx-badge\"\u003eHyper Heating to -22°F\u003c\/span\u003e \u003cspan class=\"hvx-badge\"\u003eHumidity + Refrigerant Sensors\u003c\/span\u003e \u003cspan class=\"hvx-badge\"\u003eSmart Kit + Remote + Wall Thermostat\u003c\/span\u003e \u003cspan class=\"hvx-badge\"\u003e3\/8\" \/ 3\/4\" Line Set\u003c\/span\u003e\n\u003c\/div\u003e\n\u003cul style=\"margin: 0 0 12px; padding-left: 18px;\" class=\"hvx-muted\"\u003e\n\u003cli\u003eUniversal mounting options for flexible layouts: ceiling-suspended or wall-mounted orientation.\u003c\/li\u003e\n\u003cli\u003eLong line length support for challenging installations (up to 246 ft max line length listed on outdoor unit).\u003c\/li\u003e\n\u003cli\u003eInverter-driven outdoor operation for steady temperature control and efficient performance.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cdiv class=\"hvx-grid\"\u003e\n\u003cdiv class=\"hvx-kv\"\u003e\n\u003cp class=\"hvx-k\"\u003eSystem Search\u003c\/p\u003e\n\u003cp class=\"hvx-v\"\u003e\u003ca href=\"https:\/\/hvacsupplies.com\/search?options%5Bprefix%5D=last\u0026amp;q=CH-RSH48LCFC+%2B+CH-RHP48LCU-230VO\" class=\"hvx-link\"\u003eCH-RSH48LCFC + CH-RHP48LCU-230VO\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"hvx-kv\"\u003e\n\u003cp class=\"hvx-k\"\u003eLine Set Size\u003c\/p\u003e\n\u003cp class=\"hvx-v\"\u003e3\/8\" Liquid • 3\/4\" Gas\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"hvx-kv\"\u003e\n\u003cp class=\"hvx-k\"\u003eMax Line \/ Lift\u003c\/p\u003e\n\u003cp class=\"hvx-v\"\u003e246 ft • 98.4 ft\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"hvx-kv\"\u003e\n\u003cp class=\"hvx-k\"\u003eVoltage\u003c\/p\u003e\n\u003cp class=\"hvx-v\"\u003e208–230V (187–253V)\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"hvx-kv\"\u003e\n\u003cp class=\"hvx-k\"\u003eIndoor \/ Outdoor BTU\u003c\/p\u003e\n\u003cp class=\"hvx-v\"\u003e48,000 \/ 48,000\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"hvx-kv\"\u003e\n\u003cp class=\"hvx-k\"\u003eOutdoor SEER2\u003c\/p\u003e\n\u003cp class=\"hvx-v\"\u003e18.5\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"hvx-desc-card\"\u003e\n\u003ch3 class=\"hvx-section-title\"\u003eWhat’s Included\u003c\/h3\u003e\n\u003cul style=\"margin: 0; padding-left: 18px;\" class=\"hvx-muted\"\u003e\n\u003cli\u003eUniversal floor\/ceiling indoor unit: \u003ca href=\"https:\/\/hvacsupplies.com\/search?options%5Bprefix%5D=last\u0026amp;q=CH-RSH48LCFC\" class=\"hvx-link\"\u003eCH-RSH48LCFC\u003c\/a\u003e\n\u003c\/li\u003e\n\u003cli\u003eHyper outdoor condenser: \u003ca href=\"https:\/\/hvacsupplies.com\/search?options%5Bprefix%5D=last\u0026amp;q=CH-RHP48LCU-230VO\" class=\"hvx-link\"\u003eCH-RHP48LCU-230VO\u003c\/a\u003e\n\u003c\/li\u003e\n\u003cli\u003eRemote control + wall thermostat support\u003c\/li\u003e\n\u003cli\u003eBuilt-in smart kit capability for app control (setup required)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"hvx-desc-card\"\u003e\n\u003ch3 class=\"hvx-section-title\"\u003eIndoor Specs (CH-RSH48LCFC)\u003c\/h3\u003e\n\u003cdiv class=\"hvx-table-wrap\"\u003e\n\u003ctable class=\"hvx-table\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eSpec\u003c\/th\u003e\n\u003cth\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRefrigerant Type\u003c\/td\u003e\n\u003ctd\u003eR454B\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated BTU\u003c\/td\u003e\n\u003ctd\u003e48,000\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower\u003c\/td\u003e\n\u003ctd\u003e208–230V, 1Ph, 60Hz (187–253V)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSEER2 \/ EER2\u003c\/td\u003e\n\u003ctd\u003e18.5 \/ 9.4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDehumidification\u003c\/td\u003e\n\u003ctd\u003e13.36 pints\/day\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRefrigerant Piping\u003c\/td\u003e\n\u003ctd\u003e3\/8\" Liquid • 3\/4\" Gas\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIndoor Air Flow\u003c\/td\u003e\n\u003ctd\u003e1,353.8 \/ 1,236.1 \/ 1,083.0 \/ 800.5 CFM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIndoor Noise (H\/M\/L)\u003c\/td\u003e\n\u003ctd\u003e53 \/ 48.5 \/ 39 dB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions (W×H×D)\u003c\/td\u003e\n\u003ctd\u003e64.96 × 26.57 × 9.25 in\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePacking (W×D×H)\u003c\/td\u003e\n\u003ctd\u003e67.91 × 29.72 × 12.52 in\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNet \/ Gross Weight\u003c\/td\u003e\n\u003ctd\u003e89.07 \/ 105.16 lb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Range\u003c\/td\u003e\n\u003ctd\u003eCooling: 60–90°F • Heating: 32–86°F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMCA \/ Max Fuse\u003c\/td\u003e\n\u003ctd\u003e3A \/ 15A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDrain Pipe\u003c\/td\u003e\n\u003ctd\u003e1\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"hvx-desc-card\"\u003e\n\u003ch3 class=\"hvx-section-title\"\u003eOutdoor Specs (CH-RHP48LCU-230VO)\u003c\/h3\u003e\n\u003cdiv class=\"hvx-table-wrap\"\u003e\n\u003ctable class=\"hvx-table\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eSpec\u003c\/th\u003e\n\u003cth\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRefrigerant Type\u003c\/td\u003e\n\u003ctd\u003eR454B\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated BTU\u003c\/td\u003e\n\u003ctd\u003e48,000\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSEER2 \/ EER2\u003c\/td\u003e\n\u003ctd\u003e16.7 \/ 10.4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCooling Capacity (Min\/Max)\u003c\/td\u003e\n\u003ctd\u003e48,000 (11,000–56,500) BTU\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHeating Capacity (Min\/Max)\u003c\/td\u003e\n\u003ctd\u003e52,000 (11,200–60,000) BTU\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHSPF2 (Region V \/ IV)\u003c\/td\u003e\n\u003ctd\u003e8.8 \/ 10.8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAmbient Temperature\u003c\/td\u003e\n\u003ctd\u003eCooling: -22–122°F • Heating: -22–75°F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax Pipe Length \/ Height Difference\u003c\/td\u003e\n\u003ctd\u003e246 ft \/ 98.4 ft\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions (W×D×H)\u003c\/td\u003e\n\u003ctd\u003e37.48 × 16.34 × 52.48 in\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNet \/ Gross Weight\u003c\/td\u003e\n\u003ctd\u003e208.78 \/ 239.86 lb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMCA \/ Max Fuse\u003c\/td\u003e\n\u003ctd\u003e44A \/ 45A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutdoor Noise\u003c\/td\u003e\n\u003ctd\u003e65 dB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"hvx-desc-card\"\u003e\n\u003ch3 class=\"hvx-section-title\"\u003eDocuments \u0026amp; Downloads\u003c\/h3\u003e\n\u003cul style=\"margin: 0; padding-left: 18px;\" class=\"hvx-muted\"\u003e\n\u003cli\u003e\n\u003cstrong\u003eSystem Submittal (This Combination)\u003c\/strong\u003e: \u003ca href=\"https:\/\/media.cooperandhunter.us\/4633\/CH-RHP48LCU-230VO_CH-RSH48LCFC.pdf\" class=\"hvx-link\"\u003eCH-RHP48LCU-230VO + CH-RSH48LCFC\u003c\/a\u003e\n\u003c\/li\u003e\n\u003cli style=\"margin-top: 10px;\"\u003e\u003cstrong\u003eIndoor Manuals\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/media.cooperandhunter.us\/4289\/Installation-manual-LCFC.pdf\" class=\"hvx-link\"\u003eInstallation Manual — LCFC\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/media.cooperandhunter.us\/4290\/Owners-manul-UFC_R454B.pdf\" class=\"hvx-link\"\u003eOwner’s Manual — UFC (R454B)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/media.cooperandhunter.us\/4291\/Floor-Ceiling-Leaflet-2025.pdf\" class=\"hvx-link\"\u003eFloor\/Ceiling Leaflet (2025)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli style=\"margin-top: 10px;\"\u003e\u003cstrong\u003eIndoor Reference Docs\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/media.cooperandhunter.us\/3198\/MultiZone-Combination-HYPER.pdf\" class=\"hvx-link\"\u003eMulti-Zone Combination — Hyper\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/media.cooperandhunter.us\/3199\/MultiZone-Combination-Regular.pdf\" class=\"hvx-link\"\u003eMulti-Zone Combination — Regular\u003c\/a\u003e\u003c\/li\u003e\n\u003cli style=\"margin-top: 10px;\"\u003e\u003cstrong\u003eOutdoor Manuals\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/media.cooperandhunter.us\/4200\/SlimDuct-Leaflet-R454B.pdf\" class=\"hvx-link\"\u003eSlimDuct Leaflet (R454B)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli style=\"margin-top: 10px;\"\u003e\u003cstrong\u003eOutdoor Submittals (CH-RHP48LCU-230VO)\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/media.cooperandhunter.us\/4207\/CH-RHP48LCU-230VO-%2B-CH-RS48LCDT-HS.pdf\" class=\"hvx-link\"\u003eCH-RHP48LCU-230VO + CH-RS48LCDT-HS\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/media.cooperandhunter.us\/4695\/CH-RHP48LCU-230VO_CH-RH48LCCT.pdf\" class=\"hvx-link\"\u003eCH-RHP48LCU-230VO + CH-RH48LCCT\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/media.cooperandhunter.us\/4696\/CH-RHP48LCU-230VO_CH-RSH48LCCT.pdf\" class=\"hvx-link\"\u003eCH-RHP48LCU-230VO + CH-RSH48LCCT\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"hvx-desc-card\"\u003e\n\u003ch3 class=\"hvx-section-title\"\u003eImportant\u003c\/h3\u003e\n\u003cul style=\"margin: 0; padding-left: 18px;\" class=\"hvx-muted\"\u003e\n\u003cli\u003eLine set size for this pairing: 3\/8\" liquid and 3\/4\" suction (gas).\u003c\/li\u003e\n\u003cli\u003eConfirm circuit sizing and overcurrent protection per outdoor MCA and local code requirements.\u003c\/li\u003e\n\u003cli\u003eSupport: \u003ca href=\"https:\/\/hvacsupplies.com\/pages\/contact\" class=\"hvx-link\"\u003ehvacsupplies.com\/pages\/contact\u003c\/a\u003e • \u003ca href=\"tel:+18005438933\" class=\"hvx-link\"\u003e(800) 543-8933\u003c\/a\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"hvx-desc-card hvx-faq\"\u003e\n\u003ch3 class=\"hvx-section-title\"\u003eFAQs\u003c\/h3\u003e\n\u003cdetails\u003e\n\u003csummary\u003eCan the indoor unit be installed on the ceiling or wall?\u003c\/summary\u003e\n\u003cp class=\"hvx-muted\"\u003eYes. The CH-RSH48LCFC supports ceiling (horizontal) or wall (vertical) installation.\u003c\/p\u003e\n\u003c\/details\u003e\n\u003cdetails\u003e\n\u003csummary\u003eHow cold can this Hyper system heat?\u003c\/summary\u003e\n\u003cp class=\"hvx-muted\"\u003eThe Hyper outdoor unit’s heating ambient range is listed down to -22°F.\u003c\/p\u003e\n\u003c\/details\u003e\n\u003cdetails\u003e\n\u003csummary\u003eWhat line set size does this 48K LC floor\/ceiling system use?\u003c\/summary\u003e\n\u003cp class=\"hvx-muted\"\u003eThis pairing uses a 3\/8\" liquid line and a 3\/4\" gas (suction) line.\u003c\/p\u003e\n\u003c\/details\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e","brand":"Cooper\u0026Hunter","offers":[{"title":"No installation","offer_id":42695103414315,"sku":"CH-RSH48LCFC + CH-RHP48LCU-230VO","price":5673.0,"currency_code":"USD","in_stock":true},{"title":"25FT","offer_id":42695103447083,"sku":"CH-RSH48LCFC + CH-RHP48LCU-230VO","price":6154.0,"currency_code":"USD","in_stock":true},{"title":"50FT","offer_id":42695103479851,"sku":"CH-RSH48LCFC + CH-RHP48LCU-230VO","price":6347.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0625\/5647\/1339\/files\/2-ZoneDuctlessMiniSplitAC_HeatPump48000BTU_20.png?v=1769196500"},{"product_id":"cooper-hunter-48-000-btu-single-zone-universal-floor-ceiling-minisplit-heat-pump-system-r454b-230v","title":"Cooper\u0026Hunter 48,000 BTU Single Zone Universal Floor\/Ceiling Minisplit Heat Pump System R454B 230V","description":"\u003c!-- SYSTEM 2: CH-RSH48LCFC + CH-R48LCU-230VO (REGULAR) --\u003e\n\u003cstyle\u003e\n    :root{--hvx-golden:#FAA819;--hvx-slate:#262626;--hvx-ivory:#F4F1E6;--hvx-border:#e2e0d5;--hvx-card-bg:#ffffff;}\n    .hvx-desc{background:var(--hvx-ivory);padding:18px;border-radius:18px;font-family:\"Articulat CF\",system-ui,-apple-system,Segoe UI,Roboto,Arial,sans-serif;color:#111;}\n    .hvx-desc-header{background:linear-gradient(120deg,var(--hvx-golden),var(--hvx-slate));border-radius:16px;padding:16px 16px 14px;color:#fff;margin-bottom:14px;}\n    .hvx-eyebrow{font-size:12px;letter-spacing:.12em;text-transform:uppercase;opacity:.9;margin:0 0 6px;}\n    .hvx-title{font-family:\"Anton\",Impact,Haettenschweiler,\"Arial Narrow Bold\",sans-serif;font-size:26px;line-height:1.05;margin:0;}\n    .hvx-desc-card{background:var(--hvx-card-bg);border:1px solid var(--hvx-border);border-radius:16px;padding:14px;margin:12px 0;box-shadow:0 10px 18px rgba(0,0,0,.06);}\n    .hvx-section-title{margin:0 0 10px;font-size:13px;letter-spacing:.12em;text-transform:uppercase;display:inline-block;padding-bottom:6px;position:relative;}\n    .hvx-section-title:after{content:\"\";position:absolute;left:0;bottom:0;height:3px;width:100%;border-radius:99px;background:linear-gradient(90deg,var(--hvx-golden),var(--hvx-slate));}\n    .hvx-badges{display:flex;flex-wrap:wrap;gap:8px;margin:6px 0 10px;}\n    .hvx-badge{display:inline-flex;align-items:center;gap:6px;padding:6px 10px;border-radius:999px;border:1px solid var(--hvx-border);background:#fff;font-size:12px;font-weight:600;}\n    .hvx-grid{display:grid;grid-template-columns:repeat(3,minmax(0,1fr));gap:10px;}\n    .hvx-kv{border:1px solid var(--hvx-border);border-radius:14px;padding:10px;background:#fff;}\n    .hvx-k{font-size:12px;letter-spacing:.08em;text-transform:uppercase;color:#333;margin:0 0 6px;}\n    .hvx-v{font-size:14px;font-weight:700;margin:0;}\n    .hvx-table-wrap{overflow:auto;border-radius:14px;border:1px solid var(--hvx-border);background:#fff;}\n    table.hvx-table{width:100%;border-collapse:collapse;min-width:520px;}\n    .hvx-table th,.hvx-table td{padding:10px 12px;border-bottom:1px solid var(--hvx-border);vertical-align:top;font-size:14px;}\n    .hvx-table th{background:rgba(250,168,25,.12);text-align:left;font-size:12px;letter-spacing:.1em;text-transform:uppercase;}\n    .hvx-table tr:last-child td{border-bottom:none;}\n    .hvx-link{color:#111;text-decoration:none;border-bottom:2px solid rgba(250,168,25,.7);}\n    .hvx-link:hover{border-bottom-color:#111;}\n    .hvx-faq details{border:1px solid var(--hvx-border);border-radius:14px;background:#fff;padding:10px 12px;margin:10px 0;}\n    .hvx-faq summary{cursor:pointer;font-weight:800;}\n    .hvx-muted{color:#333;margin:6px 0 0;}\n    @media (max-width:720px){.hvx-grid{grid-template-columns:1fr;}.hvx-title{font-size:24px;}}\n  \u003c\/style\u003e\n\u003cdiv class=\"hvx-desc\"\u003e\n\u003cdiv class=\"hvx-desc-header\"\u003e\n\u003cp class=\"hvx-eyebrow\"\u003eUniversal Floor\/Ceiling (Light Commercial) + Regular Outdoor • R454B • 208–230V\u003c\/p\u003e\n\u003ch2 class=\"hvx-title\"\u003eCooper\u0026amp;Hunter 48,000 BTU Single Zone Universal Floor\/Ceiling Minisplit Heat Pump System R454B 230V\u003c\/h2\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"hvx-desc-card\"\u003e\n\u003ch3 class=\"hvx-section-title\"\u003eOverview\u003c\/h3\u003e\n\u003cp class=\"hvx-muted\"\u003eThis system pairs the CH-RSH48LCFC Universal Floor\/Ceiling indoor unit (single-zone \/ light commercial) with the CH-R48LCU-230VO Regular outdoor unit. The indoor unit supports horizontal ceiling or vertical wall installation, built-in smart control capability, and humidity + refrigerant sensing. The Regular outdoor unit provides inverter heating and cooling with a heating ambient range listed to -13°F.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"hvx-desc-card\"\u003e\n\u003ch3 class=\"hvx-section-title\"\u003eHighlights\u003c\/h3\u003e\n\u003cdiv class=\"hvx-badges\"\u003e\n\u003cspan class=\"hvx-badge\"\u003eR454B Refrigerant\u003c\/span\u003e \u003cspan class=\"hvx-badge\"\u003eCeiling or Wall Install\u003c\/span\u003e \u003cspan class=\"hvx-badge\"\u003eLight Commercial Ready\u003c\/span\u003e \u003cspan class=\"hvx-badge\"\u003eInverter Comfort Control\u003c\/span\u003e \u003cspan class=\"hvx-badge\"\u003eHumidity + Refrigerant Sensors\u003c\/span\u003e \u003cspan class=\"hvx-badge\"\u003eSmart Kit + Remote + Wall Thermostat\u003c\/span\u003e \u003cspan class=\"hvx-badge\"\u003e3\/8\" \/ 3\/4\" Line Set\u003c\/span\u003e\n\u003c\/div\u003e\n\u003cul style=\"margin: 0 0 12px; padding-left: 18px;\" class=\"hvx-muted\"\u003e\n\u003cli\u003eUniversal mounting options for flexible layouts: ceiling-suspended or wall-mounted orientation.\u003c\/li\u003e\n\u003cli\u003eLong line length support for challenging installations (up to 246 ft max line length listed on outdoor unit).\u003c\/li\u003e\n\u003cli\u003eEfficient inverter outdoor operation for steady comfort and day-to-day savings.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cdiv class=\"hvx-grid\"\u003e\n\u003cdiv class=\"hvx-kv\"\u003e\n\u003cp class=\"hvx-k\"\u003eSystem Search\u003c\/p\u003e\n\u003cp class=\"hvx-v\"\u003e\u003ca href=\"https:\/\/hvacsupplies.com\/search?options%5Bprefix%5D=last\u0026amp;q=CH-RSH48LCFC+%2B+CH-R48LCU-230VO\" class=\"hvx-link\"\u003eCH-RSH48LCFC + CH-R48LCU-230VO\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"hvx-kv\"\u003e\n\u003cp class=\"hvx-k\"\u003eLine Set Size\u003c\/p\u003e\n\u003cp class=\"hvx-v\"\u003e3\/8\" Liquid • 3\/4\" Gas\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"hvx-kv\"\u003e\n\u003cp class=\"hvx-k\"\u003eMax Line \/ Lift\u003c\/p\u003e\n\u003cp class=\"hvx-v\"\u003e246 ft • 98.4 ft\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"hvx-kv\"\u003e\n\u003cp class=\"hvx-k\"\u003eVoltage\u003c\/p\u003e\n\u003cp class=\"hvx-v\"\u003e208–230V (187–253V)\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"hvx-kv\"\u003e\n\u003cp class=\"hvx-k\"\u003eOutdoor AHRI\u003c\/p\u003e\n\u003cp class=\"hvx-v\"\u003e207742340\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"hvx-kv\"\u003e\n\u003cp class=\"hvx-k\"\u003eOutdoor Dehum\u003c\/p\u003e\n\u003cp class=\"hvx-v\"\u003e9.83 pints\/day\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"hvx-desc-card\"\u003e\n\u003ch3 class=\"hvx-section-title\"\u003eWhat’s Included\u003c\/h3\u003e\n\u003cul style=\"margin: 0; padding-left: 18px;\" class=\"hvx-muted\"\u003e\n\u003cli\u003eUniversal floor\/ceiling indoor unit: \u003ca href=\"https:\/\/hvacsupplies.com\/search?options%5Bprefix%5D=last\u0026amp;q=CH-RSH48LCFC\" class=\"hvx-link\"\u003eCH-RSH48LCFC\u003c\/a\u003e\n\u003c\/li\u003e\n\u003cli\u003eRegular outdoor condenser: \u003ca href=\"https:\/\/hvacsupplies.com\/search?options%5Bprefix%5D=last\u0026amp;q=CH-R48LCU-230VO\" class=\"hvx-link\"\u003eCH-R48LCU-230VO\u003c\/a\u003e\n\u003c\/li\u003e\n\u003cli\u003eRemote control + wall thermostat support\u003c\/li\u003e\n\u003cli\u003eBuilt-in smart kit capability for app control (setup required)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"hvx-desc-card\"\u003e\n\u003ch3 class=\"hvx-section-title\"\u003eIndoor Specs (CH-RSH48LCFC)\u003c\/h3\u003e\n\u003cdiv class=\"hvx-table-wrap\"\u003e\n\u003ctable class=\"hvx-table\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eSpec\u003c\/th\u003e\n\u003cth\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRefrigerant Type\u003c\/td\u003e\n\u003ctd\u003eR454B\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated BTU\u003c\/td\u003e\n\u003ctd\u003e48,000\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower\u003c\/td\u003e\n\u003ctd\u003e208–230V, 1Ph, 60Hz (187–253V)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSEER2 \/ EER2\u003c\/td\u003e\n\u003ctd\u003e18.5 \/ 9.4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDehumidification\u003c\/td\u003e\n\u003ctd\u003e13.36 pints\/day\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRefrigerant Piping\u003c\/td\u003e\n\u003ctd\u003e3\/8\" Liquid • 3\/4\" Gas\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIndoor Air Flow\u003c\/td\u003e\n\u003ctd\u003e1,353.8 \/ 1,236.1 \/ 1,083.0 \/ 800.5 CFM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIndoor Noise (H\/M\/L)\u003c\/td\u003e\n\u003ctd\u003e53 \/ 48.5 \/ 39 dB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions (W×H×D)\u003c\/td\u003e\n\u003ctd\u003e64.96 × 26.57 × 9.25 in\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePacking (W×D×H)\u003c\/td\u003e\n\u003ctd\u003e67.91 × 29.72 × 12.52 in\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNet \/ Gross Weight\u003c\/td\u003e\n\u003ctd\u003e89.07 \/ 105.16 lb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Range\u003c\/td\u003e\n\u003ctd\u003eCooling: 60–90°F • Heating: 32–86°F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMCA \/ Max Fuse\u003c\/td\u003e\n\u003ctd\u003e3A \/ 15A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDrain Pipe\u003c\/td\u003e\n\u003ctd\u003e1\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"hvx-desc-card\"\u003e\n\u003ch3 class=\"hvx-section-title\"\u003eOutdoor Specs (CH-R48LCU-230VO)\u003c\/h3\u003e\n\u003cdiv class=\"hvx-table-wrap\"\u003e\n\u003ctable class=\"hvx-table\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eSpec\u003c\/th\u003e\n\u003cth\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRefrigerant Type\u003c\/td\u003e\n\u003ctd\u003eR454B\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated BTU\u003c\/td\u003e\n\u003ctd\u003e48,000\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCooling Capacity (Min\/Max)\u003c\/td\u003e\n\u003ctd\u003e48,000 (9,500–52,000) BTU\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHeating Capacity (Min\/Max)\u003c\/td\u003e\n\u003ctd\u003e50,000 (11,700–60,000) BTU\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHSPF2 (Region V \/ IV)\u003c\/td\u003e\n\u003ctd\u003e7.7 \/ 10.0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAmbient Temperature\u003c\/td\u003e\n\u003ctd\u003eCooling: -13–122°F • Heating: -13–75°F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax Pipe Length \/ Height Difference\u003c\/td\u003e\n\u003ctd\u003e246 ft \/ 98.4 ft\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions (W×D×H)\u003c\/td\u003e\n\u003ctd\u003e37.48 × 16.34 × 52.48 in\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNet \/ Gross Weight\u003c\/td\u003e\n\u003ctd\u003e208.78 \/ 239.86 lb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMCA \/ Max Fuse\u003c\/td\u003e\n\u003ctd\u003e39A \/ 40A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutdoor Noise\u003c\/td\u003e\n\u003ctd\u003e65 dB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAHRI\u003c\/td\u003e\n\u003ctd\u003e207742340\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"hvx-desc-card\"\u003e\n\u003ch3 class=\"hvx-section-title\"\u003eDocuments \u0026amp; Downloads\u003c\/h3\u003e\n\u003cul style=\"margin: 0; padding-left: 18px;\" class=\"hvx-muted\"\u003e\n\u003cli\u003e\n\u003cstrong\u003eSystem Submittal (This Combination)\u003c\/strong\u003e: \u003ca href=\"https:\/\/media.cooperandhunter.us\/4628\/CH-R48LCU-230VO_CH-RSH48LCFC.pdf\" class=\"hvx-link\"\u003eCH-R48LCU-230VO + CH-RSH48LCFC\u003c\/a\u003e\n\u003c\/li\u003e\n\u003cli style=\"margin-top: 10px;\"\u003e\u003cstrong\u003eIndoor Manuals\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/media.cooperandhunter.us\/4289\/Installation-manual-LCFC.pdf\" class=\"hvx-link\"\u003eInstallation Manual — LCFC\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/media.cooperandhunter.us\/4290\/Owners-manul-UFC_R454B.pdf\" class=\"hvx-link\"\u003eOwner’s Manual — UFC (R454B)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/media.cooperandhunter.us\/4291\/Floor-Ceiling-Leaflet-2025.pdf\" class=\"hvx-link\"\u003eFloor\/Ceiling Leaflet (2025)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli style=\"margin-top: 10px;\"\u003e\u003cstrong\u003eIndoor Reference Docs\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/media.cooperandhunter.us\/3198\/MultiZone-Combination-HYPER.pdf\" class=\"hvx-link\"\u003eMulti-Zone Combination — Hyper\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/media.cooperandhunter.us\/3199\/MultiZone-Combination-Regular.pdf\" class=\"hvx-link\"\u003eMulti-Zone Combination — Regular\u003c\/a\u003e\u003c\/li\u003e\n\u003cli style=\"margin-top: 10px;\"\u003e\u003cstrong\u003eOutdoor Manuals\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/media.cooperandhunter.us\/4200\/SlimDuct-Leaflet-R454B.pdf\" class=\"hvx-link\"\u003eSlimDuct Leaflet (R454B)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli style=\"margin-top: 10px;\"\u003e\u003cstrong\u003eOutdoor Submittals (CH-R48LCU-230VO)\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/media.cooperandhunter.us\/4214\/CH-R48LCU-230VO-%2B-CH-RS48LCDT-HS.pdf\" class=\"hvx-link\"\u003eCH-R48LCU-230VO + CH-RS48LCDT-HS\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/media.cooperandhunter.us\/4621\/CH-R48LCU-230VO-%2B-CH-RS48LCAHU.pdf\" class=\"hvx-link\"\u003eCH-R48LCU-230VO + CH-RS48LCAHU\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/media.cooperandhunter.us\/4691\/CH-R48LCU-230VO_CH-RH48LCCT.pdf\" class=\"hvx-link\"\u003eCH-R48LCU-230VO + CH-RH48LCCT\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/media.cooperandhunter.us\/4692\/CH-R48LCU-230VO_CH-RSH48LCCT.pdf\" class=\"hvx-link\"\u003eCH-R48LCU-230VO + CH-RSH48LCCT\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"hvx-desc-card\"\u003e\n\u003ch3 class=\"hvx-section-title\"\u003eImportant\u003c\/h3\u003e\n\u003cul style=\"margin: 0; padding-left: 18px;\" class=\"hvx-muted\"\u003e\n\u003cli\u003eLine set size for this pairing: 3\/8\" liquid and 3\/4\" suction (gas).\u003c\/li\u003e\n\u003cli\u003eConfirm circuit sizing and overcurrent protection per outdoor MCA and local code requirements.\u003c\/li\u003e\n\u003cli\u003eSupport: \u003ca href=\"https:\/\/hvacsupplies.com\/pages\/contact\" class=\"hvx-link\"\u003ehvacsupplies.com\/pages\/contact\u003c\/a\u003e • \u003ca href=\"tel:+18005438933\" class=\"hvx-link\"\u003e(800) 543-8933\u003c\/a\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"hvx-desc-card hvx-faq\"\u003e\n\u003ch3 class=\"hvx-section-title\"\u003eFAQs\u003c\/h3\u003e\n\u003cdetails\u003e\n\u003csummary\u003eCan the indoor unit be installed on the ceiling or wall?\u003c\/summary\u003e\n\u003cp class=\"hvx-muted\"\u003eYes. The CH-RSH48LCFC supports ceiling (horizontal) or wall (vertical) installation.\u003c\/p\u003e\n\u003c\/details\u003e\n\u003cdetails\u003e\n\u003csummary\u003eHow cold can this Regular system heat?\u003c\/summary\u003e\n\u003cp class=\"hvx-muted\"\u003eThe Regular outdoor unit’s heating ambient range is listed to -13°F.\u003c\/p\u003e\n\u003c\/details\u003e\n\u003cdetails\u003e\n\u003csummary\u003eWhat line set size does this 48K LC floor\/ceiling system use?\u003c\/summary\u003e\n\u003cp class=\"hvx-muted\"\u003eThis pairing uses a 3\/8\" liquid line and a 3\/4\" gas (suction) line.\u003c\/p\u003e\n\u003c\/details\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e","brand":"Cooper\u0026Hunter","offers":[{"title":"No installation","offer_id":42695112130603,"sku":"CH-RSH48LCFC + CH-R48LCU-230VO","price":4435.0,"currency_code":"USD","in_stock":true},{"title":"25FT","offer_id":42695112163371,"sku":"CH-RSH48LCFC + CH-R48LCU-230VO","price":4916.0,"currency_code":"USD","in_stock":true},{"title":"50FT","offer_id":42695112196139,"sku":"CH-RSH48LCFC + CH-R48LCU-230VO","price":5109.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0625\/5647\/1339\/files\/2-ZoneDuctlessMiniSplitAC_HeatPump48000BTU_19.png?v=1769196461"},{"product_id":"cooper-hunter-60-000-btu-hyper-single-zone-universal-floor-ceiling-minisplit-heat-pump-system-r454b-230v","title":"Cooper\u0026Hunter 60,000 BTU Hyper Single Zone Universal Floor\/Ceiling Minisplit Heat Pump System R454B 230V","description":"\u003c!-- SYSTEM 1: CH-RSH60LCFC + CH-RHP60LCU-230VO (HYPER) --\u003e\n\u003cstyle\u003e\n    :root{--hvx-golden:#FAA819;--hvx-slate:#262626;--hvx-ivory:#F4F1E6;--hvx-border:#e2e0d5;--hvx-card-bg:#ffffff;}\n    .hvx-desc{background:var(--hvx-ivory);padding:18px;border-radius:18px;font-family:\"Articulat CF\",system-ui,-apple-system,Segoe UI,Roboto,Arial,sans-serif;color:#111;}\n    .hvx-desc-header{background:linear-gradient(120deg,var(--hvx-golden),var(--hvx-slate));border-radius:16px;padding:16px 16px 14px;color:#fff;margin-bottom:14px;}\n    .hvx-eyebrow{font-size:12px;letter-spacing:.12em;text-transform:uppercase;opacity:.9;margin:0 0 6px;}\n    .hvx-title{font-family:\"Anton\",Impact,Haettenschweiler,\"Arial Narrow Bold\",sans-serif;font-size:26px;line-height:1.05;margin:0;}\n    .hvx-desc-card{background:var(--hvx-card-bg);border:1px solid var(--hvx-border);border-radius:16px;padding:14px;margin:12px 0;box-shadow:0 10px 18px rgba(0,0,0,.06);}\n    .hvx-section-title{margin:0 0 10px;font-size:13px;letter-spacing:.12em;text-transform:uppercase;display:inline-block;padding-bottom:6px;position:relative;}\n    .hvx-section-title:after{content:\"\";position:absolute;left:0;bottom:0;height:3px;width:100%;border-radius:99px;background:linear-gradient(90deg,var(--hvx-golden),var(--hvx-slate));}\n    .hvx-badges{display:flex;flex-wrap:wrap;gap:8px;margin:6px 0 10px;}\n    .hvx-badge{display:inline-flex;align-items:center;gap:6px;padding:6px 10px;border-radius:999px;border:1px solid var(--hvx-border);background:#fff;font-size:12px;font-weight:600;}\n    .hvx-grid{display:grid;grid-template-columns:repeat(3,minmax(0,1fr));gap:10px;}\n    .hvx-kv{border:1px solid var(--hvx-border);border-radius:14px;padding:10px;background:#fff;}\n    .hvx-k{font-size:12px;letter-spacing:.08em;text-transform:uppercase;color:#333;margin:0 0 6px;}\n    .hvx-v{font-size:14px;font-weight:700;margin:0;}\n    .hvx-table-wrap{overflow:auto;border-radius:14px;border:1px solid var(--hvx-border);background:#fff;}\n    table.hvx-table{width:100%;border-collapse:collapse;min-width:520px;}\n    .hvx-table th,.hvx-table td{padding:10px 12px;border-bottom:1px solid var(--hvx-border);vertical-align:top;font-size:14px;}\n    .hvx-table th{background:rgba(250,168,25,.12);text-align:left;font-size:12px;letter-spacing:.1em;text-transform:uppercase;}\n    .hvx-table tr:last-child td{border-bottom:none;}\n    .hvx-link{color:#111;text-decoration:none;border-bottom:2px solid rgba(250,168,25,.7);}\n    .hvx-link:hover{border-bottom-color:#111;}\n    .hvx-faq details{border:1px solid var(--hvx-border);border-radius:14px;background:#fff;padding:10px 12px;margin:10px 0;}\n    .hvx-faq summary{cursor:pointer;font-weight:800;}\n    .hvx-muted{color:#333;margin:6px 0 0;}\n    @media (max-width:720px){.hvx-grid{grid-template-columns:1fr;}.hvx-title{font-size:24px;}}\n  \u003c\/style\u003e\n\u003cdiv class=\"hvx-desc\"\u003e\n\u003cdiv class=\"hvx-desc-header\"\u003e\n\u003cp class=\"hvx-eyebrow\"\u003eUniversal Floor\/Ceiling (Light Commercial) + Hyper Outdoor • R454B • 208–230V\u003c\/p\u003e\n\u003ch2 class=\"hvx-title\"\u003eCooper\u0026amp;Hunter 60,000 BTU Hyper Single Zone Universal Floor\/Ceiling Minisplit Heat Pump System R454B 230V\u003c\/h2\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"hvx-desc-card\"\u003e\n\u003ch3 class=\"hvx-section-title\"\u003eOverview\u003c\/h3\u003e\n\u003cp class=\"hvx-muted\"\u003eThis system pairs the CH-RSH60LCFC Universal Floor\/Ceiling indoor unit (single-zone \/ light commercial) with the CH-RHP60LCU-230VO Hyper outdoor unit. The indoor unit supports horizontal ceiling or vertical wall installation and uses R454B refrigerant with 3\/8\" liquid and 3\/4\" gas piping. The Hyper outdoor unit is built for cold-climate heating operation, with a heating ambient range listed down to -22°F.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"hvx-desc-card\"\u003e\n\u003ch3 class=\"hvx-section-title\"\u003eHighlights\u003c\/h3\u003e\n\u003cdiv class=\"hvx-badges\"\u003e\n\u003cspan class=\"hvx-badge\"\u003eR454B Refrigerant\u003c\/span\u003e \u003cspan class=\"hvx-badge\"\u003eCeiling or Wall Install\u003c\/span\u003e \u003cspan class=\"hvx-badge\"\u003eLight Commercial Ready\u003c\/span\u003e \u003cspan class=\"hvx-badge\"\u003eHyper Heating to -22°F\u003c\/span\u003e \u003cspan class=\"hvx-badge\"\u003eInverter Outdoor Control\u003c\/span\u003e \u003cspan class=\"hvx-badge\"\u003e3\/8\" \/ 3\/4\" Line Set\u003c\/span\u003e \u003cspan class=\"hvx-badge\"\u003eAHRI: 205287344\u003c\/span\u003e\n\u003c\/div\u003e\n\u003cul style=\"margin: 0 0 12px; padding-left: 18px;\" class=\"hvx-muted\"\u003e\n\u003cli\u003eFlexible installation options: ceiling-suspended or wall-mounted orientation.\u003c\/li\u003e\n\u003cli\u003eLong-reach installation support (up to 246 ft max line length and 98.4 ft max height difference listed).\u003c\/li\u003e\n\u003cli\u003eHyper outdoor heating range supports operation in extreme cold climates.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cdiv class=\"hvx-grid\"\u003e\n\u003cdiv class=\"hvx-kv\"\u003e\n\u003cp class=\"hvx-k\"\u003eSystem Search\u003c\/p\u003e\n\u003cp class=\"hvx-v\"\u003e\u003ca href=\"https:\/\/hvacsupplies.com\/search?options%5Bprefix%5D=last\u0026amp;q=CH-RSH60LCFC+%2B+CH-RHP60LCU-230VO\" class=\"hvx-link\"\u003eCH-RSH60LCFC + CH-RHP60LCU-230VO\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"hvx-kv\"\u003e\n\u003cp class=\"hvx-k\"\u003eLine Set Size\u003c\/p\u003e\n\u003cp class=\"hvx-v\"\u003e3\/8\" Liquid • 3\/4\" Gas\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"hvx-kv\"\u003e\n\u003cp class=\"hvx-k\"\u003eMax Line \/ Lift\u003c\/p\u003e\n\u003cp class=\"hvx-v\"\u003e246 ft • 98.4 ft\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"hvx-kv\"\u003e\n\u003cp class=\"hvx-k\"\u003eVoltage\u003c\/p\u003e\n\u003cp class=\"hvx-v\"\u003e208–230V (187–253V)\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"hvx-kv\"\u003e\n\u003cp class=\"hvx-k\"\u003eOutdoor SEER2\u003c\/p\u003e\n\u003cp class=\"hvx-v\"\u003e18\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"hvx-kv\"\u003e\n\u003cp class=\"hvx-k\"\u003eOutdoor MCA \/ Max Fuse\u003c\/p\u003e\n\u003cp class=\"hvx-v\"\u003e44A • 45A\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"hvx-desc-card\"\u003e\n\u003ch3 class=\"hvx-section-title\"\u003eWhat’s Included\u003c\/h3\u003e\n\u003cul style=\"margin: 0; padding-left: 18px;\" class=\"hvx-muted\"\u003e\n\u003cli\u003eUniversal floor\/ceiling indoor unit: \u003ca href=\"https:\/\/hvacsupplies.com\/search?options%5Bprefix%5D=last\u0026amp;q=CH-RSH60LCFC\" class=\"hvx-link\"\u003eCH-RSH60LCFC\u003c\/a\u003e\n\u003c\/li\u003e\n\u003cli\u003eHyper outdoor condenser: \u003ca href=\"https:\/\/hvacsupplies.com\/search?options%5Bprefix%5D=last\u0026amp;q=CH-RHP60LCU-230VO\" class=\"hvx-link\"\u003eCH-RHP60LCU-230VO\u003c\/a\u003e\n\u003c\/li\u003e\n\u003cli\u003eRemote control + wall thermostat support\u003c\/li\u003e\n\u003cli\u003eBuilt-in smart kit capability for app control (setup required)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"hvx-desc-card\"\u003e\n\u003ch3 class=\"hvx-section-title\"\u003eIndoor Specs (CH-RSH60LCFC)\u003c\/h3\u003e\n\u003cdiv class=\"hvx-table-wrap\"\u003e\n\u003ctable class=\"hvx-table\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eSpec\u003c\/th\u003e\n\u003cth\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated V-Ph-Hz\u003c\/td\u003e\n\u003ctd\u003e208\/230, 1, 60\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCooling \/ Heating\u003c\/td\u003e\n\u003ctd\u003e54,000 \/ 60,000 BTU\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMCA \/ Max Fuse\u003c\/td\u003e\n\u003ctd\u003e3A \/ 15A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIndoor Air Flow (Turbo\/Hi\/Mi\/Lo\/Si)\u003c\/td\u003e\n\u003ctd\u003e1365.6 \/ 1236.1 \/ 1083.0 \/ 892.8 \/ 777.0 CFM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIndoor Noise (Hi\/Mi\/Lo\/Si)\u003c\/td\u003e\n\u003ctd\u003e54.5 \/ 49.4 \/ 41.5 \/ 38.5 dB(A)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions (W×D×H)\u003c\/td\u003e\n\u003ctd\u003e64.9 × 26.5 × 7.9 in\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePacking (W×D×H)\u003c\/td\u003e\n\u003ctd\u003e67.9 × 29.7 × 12.5 in\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNet \/ Gross Weight\u003c\/td\u003e\n\u003ctd\u003e95.24 \/ 111.33 lb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Range\u003c\/td\u003e\n\u003ctd\u003eCooling: 60–90°F • Heating: 32–86°F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRefrigerant Piping\u003c\/td\u003e\n\u003ctd\u003e3\/8\" Liquid • 3\/4\" Gas\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"hvx-desc-card\"\u003e\n\u003ch3 class=\"hvx-section-title\"\u003eOutdoor Specs (CH-RHP60LCU-230VO)\u003c\/h3\u003e\n\u003cdiv class=\"hvx-table-wrap\"\u003e\n\u003ctable class=\"hvx-table\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eSpec\u003c\/th\u003e\n\u003cth\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRefrigerant Type\u003c\/td\u003e\n\u003ctd\u003eR454B\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated BTU\u003c\/td\u003e\n\u003ctd\u003e60,000\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSEER2 \/ EER2\u003c\/td\u003e\n\u003ctd\u003e15.8 \/ 10.2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCooling Capacity (Min\/Max)\u003c\/td\u003e\n\u003ctd\u003e55,000 (14,200–60,000) BTU\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHeating Capacity (Min\/Max)\u003c\/td\u003e\n\u003ctd\u003e60,000 (11,200–66,000) BTU\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHSPF2 (Region V \/ IV)\u003c\/td\u003e\n\u003ctd\u003e8.7 \/ 10.4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAmbient Temperature\u003c\/td\u003e\n\u003ctd\u003eCooling: -22–122°F • Heating: -22–75°F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax Pipe Length \/ Height Difference\u003c\/td\u003e\n\u003ctd\u003e246 ft \/ 98.4 ft\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVoltage Range\u003c\/td\u003e\n\u003ctd\u003e187–253V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDehumidification\u003c\/td\u003e\n\u003ctd\u003e7.67 pints\/day\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions (W×H×D)\u003c\/td\u003e\n\u003ctd\u003e37.48 × 16.34 × 52.48 in\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNet \/ Gross Weight\u003c\/td\u003e\n\u003ctd\u003e230.38 \/ 261.69 lb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMCA \/ Max Fuse\u003c\/td\u003e\n\u003ctd\u003e44A \/ 45A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutdoor Noise\u003c\/td\u003e\n\u003ctd\u003e63 dB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAHRI\u003c\/td\u003e\n\u003ctd\u003e205287344\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"hvx-desc-card\"\u003e\n\u003ch3 class=\"hvx-section-title\"\u003eDocuments \u0026amp; Downloads\u003c\/h3\u003e\n\u003cul style=\"margin: 0; padding-left: 18px;\" class=\"hvx-muted\"\u003e\n\u003cli\u003e\n\u003cstrong\u003eSystem Submittal (This Combination)\u003c\/strong\u003e: \u003ca href=\"https:\/\/media.cooperandhunter.us\/4634\/CH-RHP60LCU-230VO_CH-RSH60LCFC.pdf\" class=\"hvx-link\"\u003eCH-RHP60LCU-230VO + CH-RSH60LCFC\u003c\/a\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cul class=\"hvx-muted\" style=\"margin: 0; padding-left: 18px;\"\u003e\n\u003cli style=\"font-weight: bold;\"\u003e\u003cstrong\u003eIndoor Manuals\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca rel=\"noopener\" href=\"https:\/\/media.cooperandhunter.us\/4289\/Installation-manual-LCFC.pdf\" target=\"_blank\"\u003eInstallation Manual\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca rel=\"noopener\" href=\"https:\/\/media.cooperandhunter.us\/4291\/Floor-Ceiling-Leaflet-2025.pdf\" target=\"_blank\"\u003eUFC Leaflet (R454B)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca rel=\"noopener\" href=\"https:\/\/media.cooperandhunter.us\/4290\/Owners-manul-UFC_R454B.pdf\" target=\"_blank\"\u003eOwners Manual\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cul style=\"margin: 0; padding-left: 18px;\" class=\"hvx-muted\"\u003e\n\u003cli style=\"margin-top: 10px;\"\u003e\u003cstrong\u003eOutdoor Manuals\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/media.cooperandhunter.us\/4200\/SlimDuct-Leaflet-R454B.pdf\" class=\"hvx-link\"\u003eUFC Leaflet (R454B)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli style=\"margin-top: 10px;\"\u003e\u003cstrong\u003eOutdoor Submittals (CH-RHP60LCU-230VO)\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/media.cooperandhunter.us\/4208\/CH-RHP60LCU-230VO-%2B-CH-RS60LCDT-HS.pdf\" class=\"hvx-link\"\u003eCH-RHP60LCU-230VO + CH-RS60LCDT-HS\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/media.cooperandhunter.us\/4435\/CH-RHP60LCU-230VO-%2B-CH-RS60LCAHU.pdf\" class=\"hvx-link\"\u003eCH-RHP60LCU-230VO + CH-RS60LCAHU\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"hvx-desc-card\"\u003e\n\u003ch3 class=\"hvx-section-title\"\u003eImportant\u003c\/h3\u003e\n\u003cul style=\"margin: 0; padding-left: 18px;\" class=\"hvx-muted\"\u003e\n\u003cli\u003eLine set size for this pairing: 3\/8\" liquid and 3\/4\" suction (gas).\u003c\/li\u003e\n\u003cli\u003eConfirm circuit sizing and overcurrent protection per outdoor MCA and local code requirements.\u003c\/li\u003e\n\u003cli\u003eSupport: \u003ca href=\"https:\/\/hvacsupplies.com\/pages\/contact\" class=\"hvx-link\"\u003ehvacsupplies.com\/pages\/contact\u003c\/a\u003e • \u003ca href=\"tel:+18005438933\" class=\"hvx-link\"\u003e(800) 543-8933\u003c\/a\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"hvx-desc-card hvx-faq\"\u003e\n\u003ch3 class=\"hvx-section-title\"\u003eFAQs\u003c\/h3\u003e\n\u003cdetails\u003e\n\u003csummary\u003eCan the indoor unit be installed on the ceiling or wall?\u003c\/summary\u003e\n\u003cp class=\"hvx-muted\"\u003eYes. The CH-RSH60LCFC supports ceiling (horizontal) or wall (vertical) installation.\u003c\/p\u003e\n\u003c\/details\u003e\n\u003cdetails\u003e\n\u003csummary\u003eHow cold can this Hyper system heat?\u003c\/summary\u003e\n\u003cp class=\"hvx-muted\"\u003eThe Hyper outdoor unit’s heating ambient range is listed down to -22°F.\u003c\/p\u003e\n\u003c\/details\u003e\n\u003cdetails\u003e\n\u003csummary\u003eWhat line set size does this 60K LC floor\/ceiling system use?\u003c\/summary\u003e\n\u003cp class=\"hvx-muted\"\u003eThis pairing uses a 3\/8\" liquid line and a 3\/4\" gas (suction) line.\u003c\/p\u003e\n\u003c\/details\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e","brand":"Cooper\u0026Hunter","offers":[{"title":"No installation","offer_id":42695114817579,"sku":"CH-RSH60LCFC + CH-RHP60LCU-230VO","price":6653.0,"currency_code":"USD","in_stock":true},{"title":"25FT","offer_id":42695114850347,"sku":"CH-RSH60LCFC + CH-RHP60LCU-230VO","price":7134.0,"currency_code":"USD","in_stock":true},{"title":"50FT","offer_id":42695114883115,"sku":"CH-RSH60LCFC + CH-RHP60LCU-230VO","price":7327.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0625\/5647\/1339\/files\/2-ZoneDuctlessMiniSplitAC_HeatPump48000BTU_20.png?v=1769196500"},{"product_id":"cooper-hunter-60-000-btu-single-zone-universal-floor-ceiling-minisplit-heat-pump-system-r454b-230v","title":"Cooper\u0026Hunter 60,000 BTU Single Zone Universal Floor\/Ceiling Minisplit Heat Pump System R454B 230V","description":"\u003c!-- SYSTEM 1: CH-RSH48LCFC + CH-RHP48LCU-230VO (HYPER) --\u003e\n\u003cstyle\u003e\n    :root{--hvx-golden:#FAA819;--hvx-slate:#262626;--hvx-ivory:#F4F1E6;--hvx-border:#e2e0d5;--hvx-card-bg:#ffffff;}\n    .hvx-desc{background:var(--hvx-ivory);padding:18px;border-radius:18px;font-family:\"Articulat CF\",system-ui,-apple-system,Segoe UI,Roboto,Arial,sans-serif;color:#111;}\n    .hvx-desc-header{background:linear-gradient(120deg,var(--hvx-golden),var(--hvx-slate));border-radius:16px;padding:16px 16px 14px;color:#fff;margin-bottom:14px;}\n    .hvx-eyebrow{font-size:12px;letter-spacing:.12em;text-transform:uppercase;opacity:.9;margin:0 0 6px;}\n    .hvx-title{font-family:\"Anton\",Impact,Haettenschweiler,\"Arial Narrow Bold\",sans-serif;font-size:26px;line-height:1.05;margin:0;}\n    .hvx-desc-card{background:var(--hvx-card-bg);border:1px solid var(--hvx-border);border-radius:16px;padding:14px;margin:12px 0;box-shadow:0 10px 18px rgba(0,0,0,.06);}\n    .hvx-section-title{margin:0 0 10px;font-size:13px;letter-spacing:.12em;text-transform:uppercase;display:inline-block;padding-bottom:6px;position:relative;}\n    .hvx-section-title:after{content:\"\";position:absolute;left:0;bottom:0;height:3px;width:100%;border-radius:99px;background:linear-gradient(90deg,var(--hvx-golden),var(--hvx-slate));}\n    .hvx-badges{display:flex;flex-wrap:wrap;gap:8px;margin:6px 0 10px;}\n    .hvx-badge{display:inline-flex;align-items:center;gap:6px;padding:6px 10px;border-radius:999px;border:1px solid var(--hvx-border);background:#fff;font-size:12px;font-weight:600;}\n    .hvx-grid{display:grid;grid-template-columns:repeat(3,minmax(0,1fr));gap:10px;}\n    .hvx-kv{border:1px solid var(--hvx-border);border-radius:14px;padding:10px;background:#fff;}\n    .hvx-k{font-size:12px;letter-spacing:.08em;text-transform:uppercase;color:#333;margin:0 0 6px;}\n    .hvx-v{font-size:14px;font-weight:700;margin:0;}\n    .hvx-table-wrap{overflow:auto;border-radius:14px;border:1px solid var(--hvx-border);background:#fff;}\n    table.hvx-table{width:100%;border-collapse:collapse;min-width:520px;}\n    .hvx-table th,.hvx-table td{padding:10px 12px;border-bottom:1px solid var(--hvx-border);vertical-align:top;font-size:14px;}\n    .hvx-table th{background:rgba(250,168,25,.12);text-align:left;font-size:12px;letter-spacing:.1em;text-transform:uppercase;}\n    .hvx-table tr:last-child td{border-bottom:none;}\n    .hvx-link{color:#111;text-decoration:none;border-bottom:2px solid rgba(250,168,25,.7);}\n    .hvx-link:hover{border-bottom-color:#111;}\n    .hvx-faq details{border:1px solid var(--hvx-border);border-radius:14px;background:#fff;padding:10px 12px;margin:10px 0;}\n    .hvx-faq summary{cursor:pointer;font-weight:800;}\n    .hvx-muted{color:#333;margin:6px 0 0;}\n    @media (max-width:720px){.hvx-grid{grid-template-columns:1fr;}.hvx-title{font-size:24px;}}\n  \u003c\/style\u003e\n\u003cdiv class=\"hvx-desc\"\u003e\n\u003cdiv class=\"hvx-desc-header\"\u003e\n\u003cp class=\"hvx-eyebrow\"\u003eUniversal Floor\/Ceiling (Light Commercial) + Hyper Outdoor • R454B • 208–230V\u003c\/p\u003e\n\u003ch2 class=\"hvx-title\"\u003eCooper\u0026amp;Hunter 48,000 BTU Hyper Single Zone Universal Floor\/Ceiling Minisplit Heat Pump System R454B 230V\u003c\/h2\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"hvx-desc-card\"\u003e\n\u003ch3 class=\"hvx-section-title\"\u003eOverview\u003c\/h3\u003e\n\u003cp class=\"hvx-muted\"\u003eThis system pairs the CH-RSH48LCFC Universal Floor\/Ceiling indoor unit (single-zone \/ light commercial) with the CH-RHP48LCU-230VO Hyper outdoor unit. The indoor unit supports horizontal ceiling or vertical wall installation, built-in smart control capability, and humidity + refrigerant sensing. The Hyper outdoor unit is built for cold-climate heating performance with a heating ambient range listed down to -22°F.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"hvx-desc-card\"\u003e\n\u003ch3 class=\"hvx-section-title\"\u003eHighlights\u003c\/h3\u003e\n\u003cdiv class=\"hvx-badges\"\u003e\n\u003cspan class=\"hvx-badge\"\u003eR454B Refrigerant\u003c\/span\u003e \u003cspan class=\"hvx-badge\"\u003eCeiling or Wall Install\u003c\/span\u003e \u003cspan class=\"hvx-badge\"\u003eLight Commercial Ready\u003c\/span\u003e \u003cspan class=\"hvx-badge\"\u003eHyper Heating to -22°F\u003c\/span\u003e \u003cspan class=\"hvx-badge\"\u003eHumidity + Refrigerant Sensors\u003c\/span\u003e \u003cspan class=\"hvx-badge\"\u003eSmart Kit + Remote + Wall Thermostat\u003c\/span\u003e \u003cspan class=\"hvx-badge\"\u003e3\/8\" \/ 3\/4\" Line Set\u003c\/span\u003e\n\u003c\/div\u003e\n\u003cul style=\"margin: 0 0 12px; padding-left: 18px;\" class=\"hvx-muted\"\u003e\n\u003cli\u003eUniversal mounting options for flexible layouts: ceiling-suspended or wall-mounted orientation.\u003c\/li\u003e\n\u003cli\u003eLong line length support for challenging installations (up to 246 ft max line length listed on outdoor unit).\u003c\/li\u003e\n\u003cli\u003eInverter-driven outdoor operation for steady temperature control and efficient performance.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cdiv class=\"hvx-grid\"\u003e\n\u003cdiv class=\"hvx-kv\"\u003e\n\u003cp class=\"hvx-k\"\u003eSystem Search\u003c\/p\u003e\n\u003cp class=\"hvx-v\"\u003e\u003ca href=\"https:\/\/hvacsupplies.com\/search?options%5Bprefix%5D=last\u0026amp;q=CH-RSH48LCFC+%2B+CH-RHP48LCU-230VO\" class=\"hvx-link\"\u003eCH-RSH48LCFC + CH-RHP48LCU-230VO\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"hvx-kv\"\u003e\n\u003cp class=\"hvx-k\"\u003eLine Set Size\u003c\/p\u003e\n\u003cp class=\"hvx-v\"\u003e3\/8\" Liquid • 3\/4\" Gas\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"hvx-kv\"\u003e\n\u003cp class=\"hvx-k\"\u003eMax Line \/ Lift\u003c\/p\u003e\n\u003cp class=\"hvx-v\"\u003e246 ft • 98.4 ft\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"hvx-kv\"\u003e\n\u003cp class=\"hvx-k\"\u003eVoltage\u003c\/p\u003e\n\u003cp class=\"hvx-v\"\u003e208–230V (187–253V)\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"hvx-kv\"\u003e\n\u003cp class=\"hvx-k\"\u003eIndoor \/ Outdoor BTU\u003c\/p\u003e\n\u003cp class=\"hvx-v\"\u003e48,000 \/ 48,000\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"hvx-kv\"\u003e\n\u003cp class=\"hvx-k\"\u003eOutdoor SEER2\u003c\/p\u003e\n\u003cp class=\"hvx-v\"\u003e18.5\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"hvx-desc-card\"\u003e\n\u003ch3 class=\"hvx-section-title\"\u003eWhat’s Included\u003c\/h3\u003e\n\u003cul style=\"margin: 0; padding-left: 18px;\" class=\"hvx-muted\"\u003e\n\u003cli\u003eUniversal floor\/ceiling indoor unit: \u003ca href=\"https:\/\/hvacsupplies.com\/search?options%5Bprefix%5D=last\u0026amp;q=CH-RSH48LCFC\" class=\"hvx-link\"\u003eCH-RSH48LCFC\u003c\/a\u003e\n\u003c\/li\u003e\n\u003cli\u003eHyper outdoor condenser: \u003ca href=\"https:\/\/hvacsupplies.com\/search?options%5Bprefix%5D=last\u0026amp;q=CH-RHP48LCU-230VO\" class=\"hvx-link\"\u003eCH-RHP48LCU-230VO\u003c\/a\u003e\n\u003c\/li\u003e\n\u003cli\u003eRemote control + wall thermostat support\u003c\/li\u003e\n\u003cli\u003eBuilt-in smart kit capability for app control (setup required)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"hvx-desc-card\"\u003e\n\u003ch3 class=\"hvx-section-title\"\u003eIndoor Specs (CH-RSH48LCFC)\u003c\/h3\u003e\n\u003cdiv class=\"hvx-table-wrap\"\u003e\n\u003ctable class=\"hvx-table\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eSpec\u003c\/th\u003e\n\u003cth\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRefrigerant Type\u003c\/td\u003e\n\u003ctd\u003eR454B\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated BTU\u003c\/td\u003e\n\u003ctd\u003e48,000\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower\u003c\/td\u003e\n\u003ctd\u003e208–230V, 1Ph, 60Hz (187–253V)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSEER2 \/ EER2\u003c\/td\u003e\n\u003ctd\u003e18.5 \/ 9.4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDehumidification\u003c\/td\u003e\n\u003ctd\u003e13.36 pints\/day\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRefrigerant Piping\u003c\/td\u003e\n\u003ctd\u003e3\/8\" Liquid • 3\/4\" Gas\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIndoor Air Flow\u003c\/td\u003e\n\u003ctd\u003e1,353.8 \/ 1,236.1 \/ 1,083.0 \/ 800.5 CFM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIndoor Noise (H\/M\/L)\u003c\/td\u003e\n\u003ctd\u003e53 \/ 48.5 \/ 39 dB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions (W×H×D)\u003c\/td\u003e\n\u003ctd\u003e64.96 × 26.57 × 9.25 in\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePacking (W×D×H)\u003c\/td\u003e\n\u003ctd\u003e67.91 × 29.72 × 12.52 in\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNet \/ Gross Weight\u003c\/td\u003e\n\u003ctd\u003e89.07 \/ 105.16 lb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Range\u003c\/td\u003e\n\u003ctd\u003eCooling: 60–90°F • Heating: 32–86°F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMCA \/ Max Fuse\u003c\/td\u003e\n\u003ctd\u003e3A \/ 15A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDrain Pipe\u003c\/td\u003e\n\u003ctd\u003e1\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"hvx-desc-card\"\u003e\n\u003ch3 class=\"hvx-section-title\"\u003eOutdoor Specs (CH-RHP48LCU-230VO)\u003c\/h3\u003e\n\u003cdiv class=\"hvx-table-wrap\"\u003e\n\u003ctable class=\"hvx-table\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eSpec\u003c\/th\u003e\n\u003cth\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRefrigerant Type\u003c\/td\u003e\n\u003ctd\u003eR454B\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated BTU\u003c\/td\u003e\n\u003ctd\u003e48,000\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSEER2 \/ EER2\u003c\/td\u003e\n\u003ctd\u003e16.7 \/ 10.4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCooling Capacity (Min\/Max)\u003c\/td\u003e\n\u003ctd\u003e48,000 (11,000–56,500) BTU\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHeating Capacity (Min\/Max)\u003c\/td\u003e\n\u003ctd\u003e52,000 (11,200–60,000) BTU\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHSPF2 (Region V \/ IV)\u003c\/td\u003e\n\u003ctd\u003e8.8 \/ 10.8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAmbient Temperature\u003c\/td\u003e\n\u003ctd\u003eCooling: -22–122°F • Heating: -22–75°F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax Pipe Length \/ Height Difference\u003c\/td\u003e\n\u003ctd\u003e246 ft \/ 98.4 ft\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions (W×D×H)\u003c\/td\u003e\n\u003ctd\u003e37.48 × 16.34 × 52.48 in\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNet \/ Gross Weight\u003c\/td\u003e\n\u003ctd\u003e208.78 \/ 239.86 lb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMCA \/ Max Fuse\u003c\/td\u003e\n\u003ctd\u003e44A \/ 45A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutdoor Noise\u003c\/td\u003e\n\u003ctd\u003e65 dB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"hvx-desc-card\"\u003e\n\u003ch3 class=\"hvx-section-title\"\u003eDocuments \u0026amp; Downloads\u003c\/h3\u003e\n\u003cul style=\"margin: 0; padding-left: 18px;\" class=\"hvx-muted\"\u003e\n\u003cli\u003e\n\u003cstrong\u003eSystem Submittal (This Combination)\u003c\/strong\u003e: \u003ca href=\"https:\/\/media.cooperandhunter.us\/4633\/CH-RHP48LCU-230VO_CH-RSH48LCFC.pdf\" class=\"hvx-link\"\u003eCH-RHP48LCU-230VO + CH-RSH48LCFC\u003c\/a\u003e\n\u003c\/li\u003e\n\u003cli style=\"margin-top: 10px;\"\u003e\u003cstrong\u003eIndoor Manuals\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/media.cooperandhunter.us\/4289\/Installation-manual-LCFC.pdf\" class=\"hvx-link\"\u003eInstallation Manual — LCFC\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/media.cooperandhunter.us\/4290\/Owners-manul-UFC_R454B.pdf\" class=\"hvx-link\"\u003eOwner’s Manual — UFC (R454B)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/media.cooperandhunter.us\/4291\/Floor-Ceiling-Leaflet-2025.pdf\" class=\"hvx-link\"\u003eFloor\/Ceiling Leaflet (2025)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli style=\"margin-top: 10px;\"\u003e\u003cstrong\u003eIndoor Reference Docs\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/media.cooperandhunter.us\/3198\/MultiZone-Combination-HYPER.pdf\" class=\"hvx-link\"\u003eMulti-Zone Combination — Hyper\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/media.cooperandhunter.us\/3199\/MultiZone-Combination-Regular.pdf\" class=\"hvx-link\"\u003eMulti-Zone Combination — Regular\u003c\/a\u003e\u003c\/li\u003e\n\u003cli style=\"margin-top: 10px;\"\u003e\u003cstrong\u003eOutdoor Manuals\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/media.cooperandhunter.us\/4200\/SlimDuct-Leaflet-R454B.pdf\" class=\"hvx-link\"\u003eSlimDuct Leaflet (R454B)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli style=\"margin-top: 10px;\"\u003e\u003cstrong\u003eOutdoor Submittals (CH-RHP48LCU-230VO)\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/media.cooperandhunter.us\/4207\/CH-RHP48LCU-230VO-%2B-CH-RS48LCDT-HS.pdf\" class=\"hvx-link\"\u003eCH-RHP48LCU-230VO + CH-RS48LCDT-HS\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/media.cooperandhunter.us\/4695\/CH-RHP48LCU-230VO_CH-RH48LCCT.pdf\" class=\"hvx-link\"\u003eCH-RHP48LCU-230VO + CH-RH48LCCT\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/media.cooperandhunter.us\/4696\/CH-RHP48LCU-230VO_CH-RSH48LCCT.pdf\" class=\"hvx-link\"\u003eCH-RHP48LCU-230VO + CH-RSH48LCCT\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"hvx-desc-card\"\u003e\n\u003ch3 class=\"hvx-section-title\"\u003eImportant\u003c\/h3\u003e\n\u003cul style=\"margin: 0; padding-left: 18px;\" class=\"hvx-muted\"\u003e\n\u003cli\u003eLine set size for this pairing: 3\/8\" liquid and 3\/4\" suction (gas).\u003c\/li\u003e\n\u003cli\u003eConfirm circuit sizing and overcurrent protection per outdoor MCA and local code requirements.\u003c\/li\u003e\n\u003cli\u003eSupport: \u003ca href=\"https:\/\/hvacsupplies.com\/pages\/contact\" class=\"hvx-link\"\u003ehvacsupplies.com\/pages\/contact\u003c\/a\u003e • \u003ca href=\"tel:+18005438933\" class=\"hvx-link\"\u003e(800) 543-8933\u003c\/a\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"hvx-desc-card hvx-faq\"\u003e\n\u003ch3 class=\"hvx-section-title\"\u003eFAQs\u003c\/h3\u003e\n\u003cdetails\u003e\n\u003csummary\u003eCan the indoor unit be installed on the ceiling or wall?\u003c\/summary\u003e\n\u003cp class=\"hvx-muted\"\u003eYes. The CH-RSH48LCFC supports ceiling (horizontal) or wall (vertical) installation.\u003c\/p\u003e\n\u003c\/details\u003e\n\u003cdetails\u003e\n\u003csummary\u003eHow cold can this Hyper system heat?\u003c\/summary\u003e\n\u003cp class=\"hvx-muted\"\u003eThe Hyper outdoor unit’s heating ambient range is listed down to -22°F.\u003c\/p\u003e\n\u003c\/details\u003e\n\u003cdetails\u003e\n\u003csummary\u003eWhat line set size does this 48K LC floor\/ceiling system use?\u003c\/summary\u003e\n\u003cp class=\"hvx-muted\"\u003eThis pairing uses a 3\/8\" liquid line and a 3\/4\" gas (suction) line.\u003c\/p\u003e\n\u003c\/details\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e","brand":"Cooper\u0026Hunter","offers":[{"title":"No installation","offer_id":42695116849195,"sku":"CH-RSH60LCFC + CH-R60LCU-230VO","price":4732.0,"currency_code":"USD","in_stock":true},{"title":"25FT","offer_id":42695116881963,"sku":"CH-RSH60LCFC + CH-R60LCU-230VO","price":5213.0,"currency_code":"USD","in_stock":true},{"title":"50FT","offer_id":42695116914731,"sku":"CH-RSH60LCFC + CH-R60LCU-230VO","price":5406.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0625\/5647\/1339\/files\/UniversalFloorCeiling_Hyper_Product_Hero_60_f4a0eb69-b1bd-47c0-b86a-83693cc279bd.png?v=1769194212"},{"product_id":"cooper-hunter-60-000-btu-single-zone-universal-floor-ceiling-minisplit-heat-pump-system-r410a-230v","title":"Cooper\u0026Hunter 60,000 BTU Single Zone Universal Floor\/Ceiling Minisplit Heat Pump System R410A 230V","description":"\u003cstyle\u003e\n  :root{\n    --hvx-golden:#FAA819;\n    --hvx-slate:#262626;\n    --hvx-ivory:#F4F1E6;\n    --hvx-border:#e2e0d5;\n    --hvx-card-bg:#ffffff;\n  }\n\n  .hvx-desc{\n    font-family:\"Articulat CF\",system-ui,-apple-system,BlinkMacSystemFont,\"Segoe UI\",sans-serif;\n    color:var(--hvx-slate);\n    line-height:1.6;\n    background:var(--hvx-ivory);\n    padding:18px 18px 20px;\n    border-radius:16px;\n  }\n\n  .hvx-desc-header{\n    border-radius:14px;\n    padding:14px 16px;\n    background:linear-gradient(120deg,var(--hvx-golden),var(--hvx-slate));\n    color:#fff;\n    margin:0 0 16px;\n    box-shadow:0 10px 24px rgba(0,0,0,.22);\n    display:flex;\n    align-items:flex-start;\n    gap:12px;\n    flex-wrap:wrap;\n  }\n\n  .hvx-header-text{display:flex;flex-direction:column;gap:6px;min-width:260px}\n  .hvx-eyebrow{\n    font-size:11px;\n    letter-spacing:.14em;\n    text-transform:uppercase;\n    opacity:.9;\n  }\n  .hvx-title{\n    margin:0;\n    font-family:\"Anton\",\"Impact\",system-ui,-apple-system,BlinkMacSystemFont,\"Segoe UI\",sans-serif;\n    font-size:22px;\n    line-height:1.15;\n  }\n  .hvx-subtitle{margin:0;font-size:14px;opacity:.95}\n\n  .hvx-desc-card{\n    border:1px solid var(--hvx-border);\n    border-radius:14px;\n    background:var(--hvx-card-bg);\n    padding:16px 18px 18px;\n    box-shadow:0 4px 12px rgba(0,0,0,.06);\n    margin:14px 0;\n  }\n\n  .hvx-section-title{\n    margin:0 0 10px;\n    font-family:\"Anton\",\"Impact\",system-ui,-apple-system,BlinkMacSystemFont,\"Segoe UI\",sans-serif;\n    font-size:17px;\n    letter-spacing:.08em;\n    text-transform:uppercase;\n    color:var(--hvx-slate);\n    display:inline-flex;\n    align-items:center;\n    gap:8px;\n  }\n  .hvx-section-title::after{\n    content:\"\";\n    flex:1;\n    height:2px;\n    border-radius:999px;\n    background:linear-gradient(90deg,var(--hvx-golden),transparent);\n    opacity:.9;\n  }\n\n  .hvx-cta{display:flex;flex-wrap:wrap;gap:10px;margin:10px 0 0}\n  .hvx-cta a{\n    display:inline-flex;\n    align-items:center;\n    gap:8px;\n    padding:10px 14px;\n    border-radius:12px;\n    border:1px solid var(--hvx-border);\n    background:#fff;\n    text-decoration:none;\n    color:var(--hvx-slate);\n    font-size:14px;\n    font-weight:700;\n  }\n  .hvx-cta a.primary{\n    background:var(--hvx-slate);\n    color:#fff;\n    border-color:transparent;\n  }\n\n  .hvx-badges{display:flex;flex-wrap:wrap;gap:8px;margin:10px 0 0}\n  .hvx-badge{\n    font-size:12px;\n    border:1px solid var(--hvx-border);\n    border-radius:999px;\n    padding:6px 10px;\n    background:#fff;\n    white-space:nowrap;\n  }\n\n  .hvx-kv{\n    display:grid;\n    grid-template-columns:repeat(4,minmax(160px,1fr));\n    gap:10px;\n    margin-top:10px;\n  }\n  .hvx-kv \u003e div{\n    border:1px solid var(--hvx-border);\n    background:#fff;\n    border-radius:12px;\n    padding:10px 12px;\n    text-align:center;\n  }\n  .hvx-kv strong{display:block}\n\n  .hvx-table{\n    width:100%;\n    border-collapse:collapse;\n    min-width:520px;\n    background:#fff;\n    border:1px solid var(--hvx-border);\n    border-radius:12px;\n    overflow:hidden;\n  }\n  .hvx-table th,.hvx-table td{\n    border-bottom:1px solid var(--hvx-border);\n    padding:10px 12px;\n    vertical-align:top;\n    font-size:14px;\n  }\n  .hvx-table th{ text-align:left; font-weight:800; background:#fff; }\n  .hvx-table tr:nth-child(even) td{ background:#fbfaf6; }\n  .hvx-table tr:last-child td{ border-bottom:none; }\n  .hvx-table-wrap{ overflow:auto; border-radius:12px; }\n\n  .hvx-link{color:var(--hvx-slate); text-decoration:underline; text-underline-offset:2px}\n  .hvx-link:hover{opacity:.85}\n\n  details.hvx-faq{\n    border:1px solid var(--hvx-border);\n    background:#fff;\n    border-radius:12px;\n    padding:10px 12px;\n    margin:8px 0;\n  }\n  details.hvx-faq summary{cursor:pointer;font-weight:800}\n\n  @media(max-width:980px){\n    .hvx-kv{grid-template-columns:repeat(2,minmax(160px,1fr))}\n  }\n  @media(max-width:768px){\n    .hvx-desc{padding:14px 12px 16px;border-radius:12px}\n    .hvx-desc-header{padding:12px;border-radius:12px}\n    .hvx-title{font-size:19px}\n    .hvx-desc-card{padding:14px;margin:10px 0}\n  }\n\u003c\/style\u003e\n\n\u003cdiv class=\"hvx-desc\"\u003e\n  \u003cdiv class=\"hvx-desc-header\"\u003e\n    \u003cdiv class=\"hvx-header-text\"\u003e\n      \u003cdiv class=\"hvx-eyebrow\"\u003eCooper\u0026amp;Hunter Light Commercial • Universal Floor\/Ceiling • R410A • 208–230V\u003c\/div\u003e\n      \u003ch1 class=\"hvx-title\"\u003eCooper\u0026amp;Hunter 60,000 BTU Single Zone Universal Floor\/Ceiling Minisplit Heat Pump System R410A 230V\u003c\/h1\u003e\n      \u003cp class=\"hvx-subtitle\"\u003e\u003cstrong\u003eSystem:\u003c\/strong\u003e CH-60LCFC-W + CH-N60LCU-230VO\u003c\/p\u003e\n    \u003c\/div\u003e\n  \u003c\/div\u003e\n\n  \u003cdiv class=\"hvx-cta\" aria-label=\"Contact options\"\u003e\n    \u003ca class=\"primary\" target=\"_blank\" rel=\"noopener\" href=\"https:\/\/hvacsupplies.com\/pages\/contact\"\u003e\n      CLICK HERE TO CONTACT US FOR CUSTOM QUOTES AND QUESTIONS\n    \u003c\/a\u003e\n    \u003ca href=\"tel:+18005438933\"\u003e\n      CLICK TO CALL US 800-543-8933 FOR ANY QUESTIONS\n    \u003c\/a\u003e\n  \u003c\/div\u003e\n\n  \u003cdiv class=\"hvx-desc-card\"\u003e\n    \u003ch2 class=\"hvx-section-title\"\u003eOverview\u003c\/h2\u003e\n    \u003cp style=\"margin:0;\"\u003e\n      Universal Floor\/Ceiling units are built for flexible placement—install \u003cstrong\u003ehorizontally on a ceiling\u003c\/strong\u003e or\n      \u003cstrong\u003evertically on a wall\u003c\/strong\u003e depending on the space. This bundle pairs the \u003cstrong\u003eCH-60LCFC-W\u003c\/strong\u003e indoor unit\n      with the \u003cstrong\u003eCH-N60LCU-230VO\u003c\/strong\u003e outdoor condenser for a \u003cstrong\u003esingle-zone\u003c\/strong\u003e R410A heat pump system on\n      \u003cstrong\u003e208–230V\u003c\/strong\u003e power.\n    \u003c\/p\u003e\n    \u003cp style=\"margin:10px 0 0;\"\u003e\n      Control options include the included remote, compatibility with wired controllers (120X\/120N), and app control when used with\n      Cooper\u0026amp;Hunter’s optional WiFi kit.\n    \u003c\/p\u003e\n  \u003c\/div\u003e\n\n  \u003cdiv class=\"hvx-desc-card\"\u003e\n    \u003ch2 class=\"hvx-section-title\"\u003eHighlights\u003c\/h2\u003e\n\n    \u003cdiv class=\"hvx-badges\" role=\"list\"\u003e\n      \u003cspan class=\"hvx-badge\" role=\"listitem\"\u003eSingle Zone bundle\u003c\/span\u003e\n      \u003cspan class=\"hvx-badge\" role=\"listitem\"\u003eFloor or ceiling mount\u003c\/span\u003e\n      \u003cspan class=\"hvx-badge\" role=\"listitem\"\u003eR410A refrigerant\u003c\/span\u003e\n      \u003cspan class=\"hvx-badge\" role=\"listitem\"\u003eIndoor SEER2: 19.8\u003c\/span\u003e\n      \u003cspan class=\"hvx-badge\" role=\"listitem\"\u003eOutdoor SEER2: 17.3\u003c\/span\u003e\n      \u003cspan class=\"hvx-badge\" role=\"listitem\"\u003eLines: 3\/8\" • 7\/8\"\u003c\/span\u003e\n      \u003cspan class=\"hvx-badge\" role=\"listitem\"\u003eOutdoor max line: 213.25 ft\u003c\/span\u003e\n      \u003cspan class=\"hvx-badge\" role=\"listitem\"\u003eHeat down to -22°F ambient\u003c\/span\u003e\n      \u003cspan class=\"hvx-badge\" role=\"listitem\"\u003eAHRI Ref: 210799609\u003c\/span\u003e\n    \u003c\/div\u003e\n\n    \u003cul style=\"margin:12px 0 0; padding-left:18px;\"\u003e\n      \u003cli\u003e\n\u003cstrong\u003eFlexible installation:\u003c\/strong\u003e mount on the ceiling (horizontal) or on the wall (vertical).\u003c\/li\u003e\n      \u003cli\u003e\n\u003cstrong\u003eMultiple control paths:\u003c\/strong\u003e remote included; supports wired controllers and optional app control with WiFi kit.\u003c\/li\u003e\n      \u003cli\u003e\n\u003cstrong\u003eLong-run capable:\u003c\/strong\u003e outdoor platform supports extended line sets and significant elevation changes (see Outdoor Specs).\u003c\/li\u003e\n      \u003cli\u003e\n\u003cstrong\u003eCold-climate capable:\u003c\/strong\u003e outdoor unit supports heating in low ambient conditions down to -22°F.\u003c\/li\u003e\n    \u003c\/ul\u003e\n\n    \u003cdiv class=\"hvx-kv\" role=\"list\" aria-label=\"At-a-glance\"\u003e\n      \u003cdiv role=\"listitem\"\u003e\n\u003cstrong\u003eIndoor\u003c\/strong\u003eCH-60LCFC-W\u003c\/div\u003e\n      \u003cdiv role=\"listitem\"\u003e\n\u003cstrong\u003eOutdoor\u003c\/strong\u003eCH-N60LCU-230VO\u003c\/div\u003e\n      \u003cdiv role=\"listitem\"\u003e\n\u003cstrong\u003eCooling\u003c\/strong\u003e55,000 BTU\/h (outdoor)\u003c\/div\u003e\n      \u003cdiv role=\"listitem\"\u003e\n\u003cstrong\u003eHeat\u003c\/strong\u003e60,000 BTU\/h (10,200–62,000)\u003c\/div\u003e\n    \u003c\/div\u003e\n  \u003c\/div\u003e\n\n  \u003cdiv class=\"hvx-desc-card\"\u003e\n    \u003ch2 class=\"hvx-section-title\"\u003eWhat’s Included\u003c\/h2\u003e\n    \u003cul style=\"padding-left:18px; margin:8px 0;\"\u003e\n      \u003cli\u003eIndoor universal floor\/ceiling unit: CH-60LCFC-W\u003c\/li\u003e\n      \u003cli\u003eOutdoor condenser: CH-N60LCU-230VO\u003c\/li\u003e\n      \u003cli\u003eManufacturer documentation (see Documents \u0026amp; Downloads)\u003c\/li\u003e\n      \u003cli\u003e\n\u003cstrong\u003eInstallation kits are not included\u003c\/strong\u003e unless selected on the Variant Options (\u003cstrong\u003eNo installation\u003c\/strong\u003e, \u003cstrong\u003e16ft\u003c\/strong\u003e, \u003cstrong\u003e25ft\u003c\/strong\u003e, \u003cstrong\u003e50ft\u003c\/strong\u003e).\u003c\/li\u003e\n    \u003c\/ul\u003e\n  \u003c\/div\u003e\n\n  \u003cdiv class=\"hvx-desc-card\"\u003e\n    \u003ch2 class=\"hvx-section-title\"\u003eIndoor Specs\u003c\/h2\u003e\n    \u003cdiv class=\"hvx-table-wrap\"\u003e\n      \u003ctable class=\"hvx-table\" aria-label=\"Indoor universal floor\/ceiling specifications\"\u003e\n        \u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eSpec\u003c\/th\u003e\n\u003cth\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n        \u003ctbody\u003e\n          \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCH-60LCFC-W\u003c\/td\u003e\n\u003c\/tr\u003e\n          \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSystem type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSingle-zone unit\u003c\/td\u003e\n\u003c\/tr\u003e\n          \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRefrigerant type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eR410A\u003c\/td\u003e\n\u003c\/tr\u003e\n          \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBTU rated\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e60,000\u003c\/td\u003e\n\u003c\/tr\u003e\n          \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower source\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e208–230V, 1Ph, 60Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n          \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eVoltage range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e187–253 V\u003c\/td\u003e\n\u003c\/tr\u003e\n          \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDehumidification\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e16.00 pints\/day\u003c\/td\u003e\n\u003c\/tr\u003e\n          \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEER2\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e9.8\u003c\/td\u003e\n\u003c\/tr\u003e\n          \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSEER2\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e19.8\u003c\/td\u003e\n\u003c\/tr\u003e\n          \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRefrigerant piping (liq\/gas)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3\/8\" \/ 7\/8\"\u003c\/td\u003e\n\u003c\/tr\u003e\n          \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eController\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eRG10K-exclusive remote \u0026amp; 120X or 120N wire controller compatible\u003c\/td\u003e\n\u003c\/tr\u003e\n          \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIndoor noise (H\/M\/L)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e54 \/ 47 \/ 44 dB(A)\u003c\/td\u003e\n\u003c\/tr\u003e\n          \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIndoor air flow\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1,430 \/ 1,384.12 \/ 1,028.82 \/ 795.29 CFM\u003c\/td\u003e\n\u003c\/tr\u003e\n          \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperation range (Heating)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e32–86°F (room)\u003c\/td\u003e\n\u003c\/tr\u003e\n          \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperation range (Cooling)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e62–90°F (room)\u003c\/td\u003e\n\u003c\/tr\u003e\n          \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMinimum circuit ampacity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003c\/tr\u003e\n          \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMax fuse\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e15\u003c\/td\u003e\n\u003c\/tr\u003e\n          \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eUnit dimensions (W×H×D)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e64.96 × 26.57 × 9.25 in\u003c\/td\u003e\n\u003c\/tr\u003e\n          \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePacking dimensions (W×D×H)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e67.91 × 29.72 × 12.52 in\u003c\/td\u003e\n\u003c\/tr\u003e\n          \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNet \/ Gross weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e96.56 \/ 111.99 lb\u003c\/td\u003e\n\u003c\/tr\u003e\n          \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDrain pipe diameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1\"\u003c\/td\u003e\n\u003c\/tr\u003e\n        \u003c\/tbody\u003e\n      \u003c\/table\u003e\n    \u003c\/div\u003e\n  \u003c\/div\u003e\n\n  \u003cdiv class=\"hvx-desc-card\"\u003e\n    \u003ch2 class=\"hvx-section-title\"\u003eOutdoor Specs\u003c\/h2\u003e\n    \u003cdiv class=\"hvx-table-wrap\"\u003e\n      \u003ctable class=\"hvx-table\" aria-label=\"Outdoor condenser specifications\"\u003e\n        \u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eSpec\u003c\/th\u003e\n\u003cth\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n        \u003ctbody\u003e\n          \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCH-N60LCU-230VO\u003c\/td\u003e\n\u003c\/tr\u003e\n          \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSystem type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSingle-zone unit\u003c\/td\u003e\n\u003c\/tr\u003e\n          \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRefrigerant type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eR410A\u003c\/td\u003e\n\u003c\/tr\u003e\n          \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBTU rated\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e60,000\u003c\/td\u003e\n\u003c\/tr\u003e\n          \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower source\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e208–230V, 1Ph, 60Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n          \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eVoltage range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e187–253 V\u003c\/td\u003e\n\u003c\/tr\u003e\n          \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMax pipe length\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e213.25 ft\u003c\/td\u003e\n\u003c\/tr\u003e\n          \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMax height difference\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e98.42 ft\u003c\/td\u003e\n\u003c\/tr\u003e\n          \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRefrigerant piping (liq\/gas)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3\/8\" \/ 7\/8\"\u003c\/td\u003e\n\u003c\/tr\u003e\n          \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCooling capacity (Min\/Max)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e55,000 (20,000–55,000) BTU\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n          \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eHeating capacity (Min\/Max)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e60,000 (10,200–62,000) BTU\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n          \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSEER2\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e17.3\u003c\/td\u003e\n\u003c\/tr\u003e\n          \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEER2\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e9\u003c\/td\u003e\n\u003c\/tr\u003e\n          \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eHSPF2-5\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e8.4\u003c\/td\u003e\n\u003c\/tr\u003e\n          \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eHSPF2-4\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e10.2\u003c\/td\u003e\n\u003c\/tr\u003e\n          \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCOP\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2.98\u003c\/td\u003e\n\u003c\/tr\u003e\n          \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOutdoor noise level\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e61 dB(A)\u003c\/td\u003e\n\u003c\/tr\u003e\n          \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOutdoor air flow\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4,235.29 CFM\u003c\/td\u003e\n\u003c\/tr\u003e\n          \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMinimum circuit ampacity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e44\u003c\/td\u003e\n\u003c\/tr\u003e\n          \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMax fuse\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e60\u003c\/td\u003e\n\u003c\/tr\u003e\n          \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAmbient temp (Heating)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-22–75°F\u003c\/td\u003e\n\u003c\/tr\u003e\n          \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAmbient temp (Cooling)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e5–122°F\u003c\/td\u003e\n\u003c\/tr\u003e\n          \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eUnit dimensions (W×H×D)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e37.48 × 16.34 × 52.48 in\u003c\/td\u003e\n\u003c\/tr\u003e\n          \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNet \/ Gross weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e240.74 \/ 271.61 lb\u003c\/td\u003e\n\u003c\/tr\u003e\n          \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRefrigerant precharge\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e25\u003c\/td\u003e\n\u003c\/tr\u003e\n          \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAdditional charge (3\/8\" liquid)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.32\u003c\/td\u003e\n\u003c\/tr\u003e\n        \u003c\/tbody\u003e\n      \u003c\/table\u003e\n    \u003c\/div\u003e\n  \u003c\/div\u003e\n\n  \u003cdiv class=\"hvx-desc-card\"\u003e\n    \u003ch2 class=\"hvx-section-title\"\u003eDocuments \u0026amp; Downloads\u003c\/h2\u003e\n    \u003cul style=\"padding-left:18px; margin:8px 0;\"\u003e\n      \u003cli\u003e\u003ca class=\"hvx-link\" target=\"_blank\" rel=\"noopener\" href=\"https:\/\/media.cooperandhunter.us\/3903\/CH-N60LCU-230VO-%2B-CH-60LCFC-W.pdf\"\u003eSubmittal (PDF) — CH-N60LCU-230VO + CH-60LCFC-W\u003c\/a\u003e\u003c\/li\u003e\n      \u003cli\u003e\u003ca class=\"hvx-link\" target=\"_blank\" rel=\"noopener\" href=\"https:\/\/media.cooperandhunter.us\/3904\/CH-NHPR60LCU-230VO-%2B-CH-60LCFC-W.pdf\"\u003eSubmittal (PDF) — CH-NHPR60LCU-230VO + CH-60LCFC-W\u003c\/a\u003e\u003c\/li\u003e\n\n      \u003cli\u003e\u003ca class=\"hvx-link\" target=\"_blank\" rel=\"noopener\" href=\"https:\/\/media.cooperandhunter.us\/2217\/_UNIVERSALFLOORCEILING-BOOKLET-compressed.pdf\"\u003eUniversal Floor\/Ceiling Booklet (PDF)\u003c\/a\u003e\u003c\/li\u003e\n\n      \u003cli\u003e\u003ca class=\"hvx-link\" target=\"_blank\" rel=\"noopener\" href=\"https:\/\/media.cooperandhunter.us\/3198\/MultiZone-Combination-HYPER.pdf\"\u003eMultiZone Combination (PDF) — HYPER\u003c\/a\u003e\u003c\/li\u003e\n      \u003cli\u003e\u003ca class=\"hvx-link\" target=\"_blank\" rel=\"noopener\" href=\"https:\/\/media.cooperandhunter.us\/3199\/MultiZone-Combination-Regular.pdf\"\u003eMultiZone Combination (PDF) — Regular\u003c\/a\u003e\u003c\/li\u003e\n\n      \u003cli\u003e\u003ca class=\"hvx-link\" target=\"_blank\" rel=\"noopener\" href=\"https:\/\/media.cooperandhunter.us\/3235\/CH-N60LCU-230VO-%2B-CH-60LCDTUI.pdf\"\u003eSubmittal (PDF) — CH-N60LCU-230VO + CH-60LCDTUI\u003c\/a\u003e\u003c\/li\u003e\n      \u003cli\u003e\u003ca class=\"hvx-link\" target=\"_blank\" rel=\"noopener\" href=\"https:\/\/media.cooperandhunter.us\/3467\/CH-N60LCU-230VO-%2B-CH-60AHU.pdf\"\u003eSubmittal (PDF) — CH-N60LCU-230VO + CH-60AHU\u003c\/a\u003e\u003c\/li\u003e\n      \u003cli\u003e\u003ca class=\"hvx-link\" target=\"_blank\" rel=\"noopener\" href=\"https:\/\/media.cooperandhunter.us\/3860\/CH-N60LCU-230VO-%2B-CH-60LCFCI.pdf\"\u003eSubmittal (PDF) — CH-N60LCU-230VO + CH-60LCFCI\u003c\/a\u003e\u003c\/li\u003e\n\n      \u003cli\u003e\u003ca class=\"hvx-link\" target=\"_blank\" rel=\"noopener\" href=\"https:\/\/media.cooperandhunter.us\/3753\/AHU-leaflet.pdf\"\u003eAHU Leaflet (PDF)\u003c\/a\u003e\u003c\/li\u003e\n      \u003cli\u003e\u003ca class=\"hvx-link\" target=\"_blank\" rel=\"noopener\" href=\"https:\/\/media.cooperandhunter.us\/1769\/User-manual-36-60KAHU.pdf\"\u003eUser Manual (PDF) — 36–60K AHU\u003c\/a\u003e\u003c\/li\u003e\n\n      \u003cli\u003eAHRI Directory Reference — 210799609\u003c\/li\u003e\n    \u003c\/ul\u003e\n  \u003c\/div\u003e\n\n  \u003cdiv class=\"hvx-desc-card\"\u003e\n    \u003ch2 class=\"hvx-section-title\"\u003eVideos\u003c\/h2\u003e\n\n    \u003cp style=\"margin:0 0 6px;\"\u003e\u003cstrong\u003eMini-split installation videos\u003c\/strong\u003e\u003c\/p\u003e\n    \u003cul style=\"padding-left:18px; margin:0;\"\u003e\n      \u003cli\u003e\u003ca class=\"hvx-link\" target=\"_blank\" rel=\"noopener\" href=\"https:\/\/youtu.be\/ieOdKq8yBKY\"\u003eCooper\u0026amp;Hunter Mini Split Slim Duct Installation\u003c\/a\u003e\u003c\/li\u003e\n    \u003c\/ul\u003e\n\n    \u003cp style=\"margin:12px 0 6px;\"\u003e\u003cstrong\u003eProducts overview\u003c\/strong\u003e\u003c\/p\u003e\n    \u003cul style=\"padding-left:18px; margin:0;\"\u003e\n      \u003cli\u003e\u003ca class=\"hvx-link\" target=\"_blank\" rel=\"noopener\" href=\"https:\/\/youtu.be\/2u0pa2jThCM\"\u003eHVAC Installation Kit: 99.9% Copper Line Sets (Cooper\u0026amp;Hunter)\u003c\/a\u003e\u003c\/li\u003e\n    \u003c\/ul\u003e\n\n    \u003cp style=\"margin:12px 0 6px;\"\u003e\u003cstrong\u003eMini-Splits\u003c\/strong\u003e\u003c\/p\u003e\n    \u003cul style=\"padding-left:18px; margin:0;\"\u003e\n      \u003cli\u003e\u003ca class=\"hvx-link\" target=\"_blank\" rel=\"noopener\" href=\"https:\/\/www.youtube.com\/watch?v=n00qcO3iIR0\"\u003eCan You Use a Mini Split in EXTREME COLD? Heat Pump vs. Propane Cost Comparison with Thermal Camera\u003c\/a\u003e\u003c\/li\u003e\n    \u003c\/ul\u003e\n  \u003c\/div\u003e\n\n  \u003cdiv class=\"hvx-desc-card\"\u003e\n    \u003ch2 class=\"hvx-section-title\"\u003eImportant\u003c\/h2\u003e\n    \u003cul style=\"margin:0; padding-left:18px; font-size:14px;\"\u003e\n      \u003cli\u003eConfirm mounting orientation (ceiling vs wall), clearances, and condensate routing prior to installation.\u003c\/li\u003e\n      \u003cli\u003eVerify line size requirements (3\/8\" liquid, 7\/8\" suction) and maximum run\/height limits before ordering materials.\u003c\/li\u003e\n      \u003cli\u003e\n\u003cstrong\u003eInstallation kits are not included\u003c\/strong\u003e unless selected on the Variant Options (No installation, 16ft, 25ft, 50ft).\u003c\/li\u003e\n    \u003c\/ul\u003e\n  \u003c\/div\u003e\n\n  \u003cdiv class=\"hvx-desc-card\"\u003e\n    \u003ch2 class=\"hvx-section-title\"\u003eFAQs\u003c\/h2\u003e\n\n    \u003cdetails class=\"hvx-faq\" open\u003e\n      \u003csummary\u003eIs this a single-zone system?\u003c\/summary\u003e\n      \u003cdiv style=\"margin-top:8px;\"\u003e\n        Yes—this is a \u003cstrong\u003esingle-zone bundle\u003c\/strong\u003e pairing CH-60LCFC-W with CH-N60LCU-230VO.\n      \u003c\/div\u003e\n    \u003c\/details\u003e\n\n    \u003cdetails class=\"hvx-faq\" open\u003e\n      \u003csummary\u003eWhere can the indoor unit be installed?\u003c\/summary\u003e\n      \u003cdiv style=\"margin-top:8px;\"\u003e\n        The universal indoor unit can be installed \u003cstrong\u003ehorizontally on a ceiling\u003c\/strong\u003e or \u003cstrong\u003evertically on a wall\u003c\/strong\u003e.\n      \u003c\/div\u003e\n    \u003c\/details\u003e\n\n    \u003cdetails class=\"hvx-faq\" open\u003e\n      \u003csummary\u003eAre installation kits included?\u003c\/summary\u003e\n      \u003cdiv style=\"margin-top:8px;\"\u003e\n        No. Installation kits are only included if selected on the Variant Options (No installation, 16ft, 25ft, 50ft).\n      \u003c\/div\u003e\n    \u003c\/details\u003e\n\n    \u003cdetails class=\"hvx-faq\" open\u003e\n      \u003csummary\u003eCan I use app control?\u003c\/summary\u003e\n      \u003cdiv style=\"margin-top:8px;\"\u003e\n        App control is available when used with Cooper\u0026amp;Hunter’s optional WiFi kit and the C\u0026amp;H app.\n      \u003c\/div\u003e\n    \u003c\/details\u003e\n\n    \u003cdetails class=\"hvx-faq\" open\u003e\n      \u003csummary\u003eHow cold can this system heat?\u003c\/summary\u003e\n      \u003cdiv style=\"margin-top:8px;\"\u003e\n        The outdoor unit supports heating in ambient temperatures down to \u003cstrong\u003e-22°F\u003c\/strong\u003e.\n      \u003c\/div\u003e\n    \u003c\/details\u003e\n  \u003c\/div\u003e\n\u003c\/div\u003e","brand":"Cooper\u0026Hunter","offers":[{"title":"No installation","offer_id":43091949518891,"sku":"CH-60LCFC-W + CH-N60LCU-230VO","price":3639.33,"currency_code":"USD","in_stock":false},{"title":"25FT","offer_id":43091949551659,"sku":"CH-60LCFC-W + CH-N60LCU-230VO","price":4116.97,"currency_code":"USD","in_stock":false},{"title":"50FT","offer_id":43091949584427,"sku":"CH-60LCFC-W + CH-N60LCU-230VO","price":4308.59,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0625\/5647\/1339\/files\/UniversalFloorCeiling_Hyper_Product_Hero_60_f4a0eb69-b1bd-47c0-b86a-83693cc279bd.png?v=1769194212"}],"url":"https:\/\/hvacsupplies.com\/collections\/single-zone-universal-floor-ceiling-ufc-cooper-and-hunter.oembed","provider":"HVACSupplies.com","version":"1.0","type":"link"}