{"title":"Single Zone Four-Way Ceiling Cassette 12K-15K","description":null,"products":[{"product_id":"aciq-12-000-btu-aciq-extreme-22-2-seer2-single-zone-ceiling-cassette-mini-split-heat-pump-system-r454b-230v","title":"ACIQ 12,000 BTU ACIQ Extreme 22.2 SEER2 Single Zone Ceiling Cassette Mini Split Heat Pump System - R454B | 230V","description":"\u003cstyle\u003e\n  :root {\n    --hvx-golden: #FAA819;\n    --hvx-slate: #262626;\n    --hvx-ivory: #F4F1E6;\n    --hvx-border: #e2e0d5;\n    --hvx-card-bg: #ffffff;\n  }\n  .hvx-desc { font-family: \"Articulat CF\", system-ui, -apple-system, BlinkMacSystemFont, \"Segoe UI\", sans-serif; color: var(--hvx-slate); line-height: 1.6; background: var(--hvx-ivory); padding: 18px 18px 20px; border-radius: 16px; }\n  .hvx-desc-header { border-radius: 14px; padding: 14px 16px; background: linear-gradient(120deg, var(--hvx-golden), var(--hvx-slate)); color: #fff; margin: 0 0 16px; display: flex; flex-direction: column; gap: 6px; box-shadow: 0 10px 24px rgba(0, 0, 0, 0.22); }\n  .hvx-desc-eyebrow { font-size: 11px; letter-spacing: 0.14em; text-transform: uppercase; opacity: 0.8; }\n  .hvx-desc-title { margin: 0; font-family: \"Anton\", \"Impact\", system-ui, -apple-system, BlinkMacSystemFont, \"Segoe UI\", sans-serif; font-size: 20px; line-height: 1.2; }\n  .hvx-desc-card { border: 1px solid var(--hvx-border); border-radius: 14px; background: var(--hvx-card-bg); padding: 16px 18px 18px; box-shadow: 0 4px 12px rgba(0, 0, 0, 0.06); margin: 14px 0; }\n  .hvx-section-title { margin: 0 0 8px; font-family: \"Anton\",\"Impact\",system-ui,-apple-system,BlinkMacSystemFont,\"Segoe UI\",sans-serif; font-size: 17px; letter-spacing: .08em; text-transform: uppercase; color: var(--hvx-slate); display: inline-flex; align-items: center; gap: 8px; }\n  .hvx-section-title::after { content: \"\"; flex: 1; height: 2px; border-radius: 999px; background: linear-gradient(90deg, var(--hvx-golden), transparent); opacity: .9; }\n  .hvx-text { margin: 6px 0; font-size: 14px; }\n  .hvx-list { margin: 6px 0 10px; padding-left: 20px; font-size: 14px; }\n  .hvx-li { margin-bottom: 4px; }\n  .hvx-table-wrap { width: 100%; overflow-x: auto; }\n  .hvx-table { width: 100%; border-collapse: collapse; font-size: 13px; min-width: 520px; }\n  .hvx-th,.hvx-td { border: 1px solid var(--hvx-border); padding: 9px 11px; text-align: left; vertical-align: top; }\n  .hvx-th { background: #f7f3e8; color: var(--hvx-slate); width: 26ch; font-weight: 600; text-transform: capitalize; }\n  .hvx-link { text-decoration: underline; text-decoration-thickness: 1px; text-underline-offset: 2px; color: var(--hvx-slate); }\n  .hvx-link:hover { color: var(--hvx-golden); }\n  @media (max-width: 768px){ .hvx-desc{padding:14px 12px 16px;border-radius:12px}.hvx-desc-header{padding:12px;border-radius:12px}.hvx-desc-title{font-size:18px}.hvx-desc-card{padding:14px;margin:10px 0} }\n\u003c\/style\u003e\n\u003cdiv class=\"hvx-desc\"\u003e\n  \u003cdiv class=\"hvx-desc-header\"\u003e\n    \u003cdiv class=\"hvx-desc-eyebrow\"\u003eACIQ\u003c\/div\u003e\n    \u003cdiv class=\"hvx-desc-title\"\u003eACIQ 12,000 BTU ACIQ Extreme 22.2 SEER2 Single Zone Ceiling Cassette Mini Split Heat Pump System - R454B | 230V\u003c\/div\u003e\n  \u003c\/div\u003e\n\n  \u003cdiv class=\"hvx-desc-card\"\u003e\n\u003ch2 class=\"hvx-section-title\"\u003eProduct Overview\u003c\/h2\u003e\n\u003cstyle\u003e#html-body [data-pb-style=N315LC3]{justify-content:flex-start;display:flex;flex-direction:column;background-position:left top;background-size:cover;background-repeat:no-repeat;background-attachment:scroll;border-style:none;border-width:1px;border-radius:0;margin:0 0 10px;padding:10px}#html-body [data-pb-style=WC6AVTV]{border-style:none;border-width:1px;border-radius:0;margin:0;padding:0}\u003c\/style\u003e\n\u003cdiv\u003e\u003cdiv\u003e\u003cdiv\u003eThe ACIQ Extreme series makes ultra-high efficiency heating and cooling affordable for everyone.  With SEER as high as 25 and HSPF as high as 13 you can experience the high performance and maximum efficiency that usually costs much more. \u003c\/div\u003e\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\n  \n          \u003cdiv class=\"hvx-desc-card\"\u003e\n            \u003ch2 class=\"hvx-section-title\"\u003eTechnical Specifications — ACIQ-12ZPL-HP230C\u003c\/h2\u003e\n            \u003cdiv class=\"hvx-table-wrap\"\u003e\n              \u003ctable class=\"hvx-table\"\u003e\n                \u003ctbody\u003e\n\u003ctr\u003e\n\u003cth class=\"hvx-th\"\u003esku\u003c\/th\u003e\n\u003ctd class=\"hvx-td\"\u003eACIQ-12ZPL-HP230C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth class=\"hvx-th\"\u003erefrigerant charge\u003c\/th\u003e\n\u003ctd class=\"hvx-td\"\u003e35.27 oz.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth class=\"hvx-th\"\u003eweight\u003c\/th\u003e\n\u003ctd class=\"hvx-td\"\u003e78.700000\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth class=\"hvx-th\"\u003emanufacturer\u003c\/th\u003e\n\u003ctd class=\"hvx-td\"\u003eACiQ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth class=\"hvx-th\"\u003eproduct features\u003c\/th\u003e\n\u003ctd class=\"hvx-td\"\u003eLow Ambient Heating\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth class=\"hvx-th\"\u003ehspf2\u003c\/th\u003e\n\u003ctd class=\"hvx-td\"\u003e10.5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth class=\"hvx-th\"\u003ecooling btu\u003c\/th\u003e\n\u003ctd class=\"hvx-td\"\u003e12,000 BTU\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth class=\"hvx-th\"\u003eheating btu\u003c\/th\u003e\n\u003ctd class=\"hvx-td\"\u003e12,000 BTU\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth class=\"hvx-th\"\u003emaximum cfm\u003c\/th\u003e\n\u003ctd class=\"hvx-td\"\u003e1470.6\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth class=\"hvx-th\"\u003edecibel level (dba)\u003c\/th\u003e\n\u003ctd class=\"hvx-td\"\u003e56\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth class=\"hvx-th\"\u003eelectric heat\u003c\/th\u003e\n\u003ctd class=\"hvx-td\"\u003eHeat Pump\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth class=\"hvx-th\"\u003eenergy star\u003c\/th\u003e\n\u003ctd class=\"hvx-td\"\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth class=\"hvx-th\"\u003erefrigerant\u003c\/th\u003e\n\u003ctd class=\"hvx-td\"\u003eR454B\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth class=\"hvx-th\"\u003eseer2\u003c\/th\u003e\n\u003ctd class=\"hvx-td\"\u003e25.5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth class=\"hvx-th\"\u003ecompressor type\u003c\/th\u003e\n\u003ctd class=\"hvx-td\"\u003eRotary\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth class=\"hvx-th\"\u003eliquid line\u003c\/th\u003e\n\u003ctd class=\"hvx-td\"\u003e1\/4\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth class=\"hvx-th\"\u003esuction line\u003c\/th\u003e\n\u003ctd class=\"hvx-td\"\u003e3\/8\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth class=\"hvx-th\"\u003eelectrical\u003c\/th\u003e\n\u003ctd class=\"hvx-td\"\u003e208\/230V, 1 Phase, 60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth class=\"hvx-th\"\u003eelectric phase filter\u003c\/th\u003e\n\u003ctd class=\"hvx-td\"\u003eSingle Phase\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth class=\"hvx-th\"\u003emax breaker size\u003c\/th\u003e\n\u003ctd class=\"hvx-td\"\u003e15A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth class=\"hvx-th\"\u003emin. breaker size\u003c\/th\u003e\n\u003ctd class=\"hvx-td\"\u003e15A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth class=\"hvx-th\"\u003ebtu\/tonnage\u003c\/th\u003e\n\u003ctd class=\"hvx-td\"\u003e12,000 BTU\/1 Ton\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth class=\"hvx-th\"\u003emin\/max outdoor temp for heating\u003c\/th\u003e\n\u003ctd class=\"hvx-td\"\u003e-22~75 °F \/ -30~24 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth class=\"hvx-th\"\u003emin\/max outdoor temp for cooling\u003c\/th\u003e\n\u003ctd class=\"hvx-td\"\u003e-22~122 °F \/ -30~50 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth class=\"hvx-th\"\u003ezone compatibility\u003c\/th\u003e\n\u003ctd class=\"hvx-td\"\u003eSingle Zone\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth class=\"hvx-th\"\u003ecertification\u003c\/th\u003e\n\u003ctd class=\"hvx-td\"\u003eEnergy Star, NEEP, UL AHRI\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth class=\"hvx-th\"\u003eheight\u003c\/th\u003e\n\u003ctd class=\"hvx-td\"\u003e21.81\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth class=\"hvx-th\"\u003ewidth\u003c\/th\u003e\n\u003ctd class=\"hvx-td\"\u003e31.69\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth class=\"hvx-th\"\u003edepth\u003c\/th\u003e\n\u003ctd class=\"hvx-td\"\u003e12.99\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth class=\"hvx-th\"\u003ewarranty\u003c\/th\u003e\n\u003ctd class=\"hvx-td\"\u003e12 year compressor, 7 year parts with online registration\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth class=\"hvx-th\"\u003esafety information\u003c\/th\u003e\n\u003ctd class=\"hvx-td\"\u003ePROPOSITION 65 WARNINGThis product and many products on our site may contain a chemical know to the state of California to cause cancer or birth defects or other reproductive harm. For more information about Proposition 65 pleaseClick Here.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n              \u003c\/table\u003e\n            \u003c\/div\u003e\n          \u003c\/div\u003e\n        \n          \u003cdiv class=\"hvx-desc-card\"\u003e\n            \u003ch2 class=\"hvx-section-title\"\u003eTechnical Specifications — ACIQ-12CC-HH-MC\u003c\/h2\u003e\n            \u003cdiv class=\"hvx-table-wrap\"\u003e\n              \u003ctable class=\"hvx-table\"\u003e\n                \u003ctbody\u003e\n\u003ctr\u003e\n\u003cth class=\"hvx-th\"\u003esku\u003c\/th\u003e\n\u003ctd class=\"hvx-td\"\u003eACIQ-12CC-HH-MC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth class=\"hvx-th\"\u003eweight\u003c\/th\u003e\n\u003ctd class=\"hvx-td\"\u003e41.890000\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth class=\"hvx-th\"\u003emanufacturer\u003c\/th\u003e\n\u003ctd class=\"hvx-td\"\u003eACiQ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth class=\"hvx-th\"\u003econtroller\u003c\/th\u003e\n\u003ctd class=\"hvx-td\"\u003eWireless Included\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth class=\"hvx-th\"\u003eproduct features\u003c\/th\u003e\n\u003ctd class=\"hvx-td\"\u003eWiFi\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth class=\"hvx-th\"\u003ecooling btu\u003c\/th\u003e\n\u003ctd class=\"hvx-td\"\u003e12,000 BTU\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth class=\"hvx-th\"\u003eheating btu\u003c\/th\u003e\n\u003ctd class=\"hvx-td\"\u003e12,000 BTU\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth class=\"hvx-th\"\u003emaximum cfm\u003c\/th\u003e\n\u003ctd class=\"hvx-td\"\u003eUp to 417.9 CFM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth class=\"hvx-th\"\u003edecibel level (dba)\u003c\/th\u003e\n\u003ctd class=\"hvx-td\"\u003eAs low as 26.0 Decibels\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth class=\"hvx-th\"\u003eelectric heat\u003c\/th\u003e\n\u003ctd class=\"hvx-td\"\u003eHeat Pump\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth class=\"hvx-th\"\u003erefrigerant\u003c\/th\u003e\n\u003ctd class=\"hvx-td\"\u003eR454B\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth class=\"hvx-th\"\u003eliquid line\u003c\/th\u003e\n\u003ctd class=\"hvx-td\"\u003e1\/4\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth class=\"hvx-th\"\u003esuction line\u003c\/th\u003e\n\u003ctd class=\"hvx-td\"\u003e3\/8\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth class=\"hvx-th\"\u003eelectrical\u003c\/th\u003e\n\u003ctd class=\"hvx-td\"\u003e208\/230V, 1 Phase, 60Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth class=\"hvx-th\"\u003eelectric phase filter\u003c\/th\u003e\n\u003ctd class=\"hvx-td\"\u003eSingle Phase\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth class=\"hvx-th\"\u003ebtu\/tonnage\u003c\/th\u003e\n\u003ctd class=\"hvx-td\"\u003e12,000 BTU\/1 Ton\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth class=\"hvx-th\"\u003emini split type\u003c\/th\u003e\n\u003ctd class=\"hvx-td\"\u003eCeiling Cassette\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth class=\"hvx-th\"\u003ezone compatibility\u003c\/th\u003e\n\u003ctd class=\"hvx-td\"\u003eSingle Zone, Multi Zone\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth class=\"hvx-th\"\u003eheight\u003c\/th\u003e\n\u003ctd class=\"hvx-td\"\u003e9.65\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth class=\"hvx-th\"\u003ewidth\u003c\/th\u003e\n\u003ctd class=\"hvx-td\"\u003e22.44\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth class=\"hvx-th\"\u003edepth\u003c\/th\u003e\n\u003ctd class=\"hvx-td\"\u003e22.44\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth class=\"hvx-th\"\u003ewarranty\u003c\/th\u003e\n\u003ctd class=\"hvx-td\"\u003e12 year compressor, 7 year parts with online registration\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth class=\"hvx-th\"\u003esafety information\u003c\/th\u003e\n\u003ctd class=\"hvx-td\"\u003ePROPOSITION 65 WARNINGThis product and many products on our site may contain a chemical know to the state of California to cause cancer or birth defects or other reproductive harm. For more information about Proposition 65 pleaseClick Here.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n              \u003c\/table\u003e\n            \u003c\/div\u003e\n          \u003c\/div\u003e\n        \n  \n      \u003cdiv class=\"hvx-desc-card\"\u003e\n        \u003ch2 class=\"hvx-section-title\"\u003eManuals\u003c\/h2\u003e\n        \u003cul class=\"hvx-list\"\u003e\n\u003cli class=\"hvx-li\"\u003e\u003ca class=\"hvx-link\" href=\"https:\/\/portal.aciq.com\/media\/pdf\/ACIQ-SZ-ODU-EH-SH-sm-en-01-051625(6K-60K-NA_H_240527_33).pdf\" target=\"_blank\" rel=\"noopener\"\u003eService Manual\u003c\/a\u003e\u003c\/li\u003e\n\u003cli class=\"hvx-li\"\u003e\u003ca class=\"hvx-link\" href=\"https:\/\/portal.aciq.com\/media\/pdf\/ACiQ-EHSZ-MZ-CC-MC-im-en-01-022025(9K-48K-16122700A24835).pdf\" target=\"_blank\" rel=\"noopener\"\u003eInstallation Manual\u003c\/a\u003e\u003c\/li\u003e\n\u003cli class=\"hvx-li\"\u003e\u003ca class=\"hvx-link\" href=\"https:\/\/portal.aciq.com\/media\/pdf\/ACiQ-EHSZ-MZ-CC-MC-om-en-01-022025(9K-48K-16122700A24836).pdf\" target=\"_blank\" rel=\"noopener\"\u003eOwner's Manual\u003c\/a\u003e\u003c\/li\u003e\n\u003cli class=\"hvx-li\"\u003e\u003ca class=\"hvx-link\" href=\"https:\/\/portal.aciq.com\/media\/pdf\/ACiQ-EHSZ-MZ-CC-MC-RC-um-en-01-022025(9K-48K-16117000A49730).pdf\" target=\"_blank\" rel=\"noopener\"\u003eRemote Manual\u003c\/a\u003e\u003c\/li\u003e\n\u003cli class=\"hvx-li\"\u003e\u003ca class=\"hvx-link\" href=\"https:\/\/portal.aciq.com\/media\/pdf\/ACiQ-EHSZ-MZ-CC-MC-sm-en-01-061825(9K-48K-NA_H_240717).pdf\" target=\"_blank\" rel=\"noopener\"\u003eService Manual\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n      \u003c\/div\u003e\n    \n      \u003cdiv class=\"hvx-desc-card\"\u003e\n        \u003ch2 class=\"hvx-section-title\"\u003eDocuments\u003c\/h2\u003e\n        \u003cul class=\"hvx-list\"\u003e\n\u003cli class=\"hvx-li\"\u003e\u003ca class=\"hvx-link\" href=\"https:\/\/portal.aciq.com\/media\/pdf\/ACiQ-AHRI-EHSZ-12ZPL-HP230C-031725(Combined-All-AH).pdf\" target=\"_blank\" rel=\"noopener\"\u003eAHRI Certificates (12K with all available air handlers)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli class=\"hvx-li\"\u003e\u003ca class=\"hvx-link\" href=\"https:\/\/portal.aciq.com\/media\/pdf\/ACiQ-CC-Sub-12CC-MC-12ZPL-HP230C-063024.pdf\" target=\"_blank\" rel=\"noopener\"\u003eSubmittal with 12K Ceiling Cassette\u003c\/a\u003e\u003c\/li\u003e\n\u003cli class=\"hvx-li\"\u003e\u003ca class=\"hvx-link\" href=\"https:\/\/portal.aciq.com\/media\/pdf\/ACiQ-CD-Sub-12CD-HH-MC-12ZPL-HP230C-061424.pdf\" target=\"_blank\" rel=\"noopener\"\u003eSubmittal with 12K Concealed Duct\u003c\/a\u003e\u003c\/li\u003e\n\u003cli class=\"hvx-li\"\u003e\u003ca class=\"hvx-link\" href=\"https:\/\/portal.aciq.com\/media\/pdf\/ACiQ-FM-Sub-12FM-MD-12ZPL-HP230C-061024.pdf\" target=\"_blank\" rel=\"noopener\"\u003eSubmittal with 12K Floor\/Ceiling Mount\u003c\/a\u003e\u003c\/li\u003e\n\u003cli class=\"hvx-li\"\u003e\u003ca class=\"hvx-link\" href=\"https:\/\/portal.aciq.com\/media\/pdf\/ACIQ-SCC-Sub-12SCC-MB-12ZPL-HP230C-060524.pdf\" target=\"_blank\" rel=\"noopener\"\u003eSubmittal with 12K Slim Ceiling Cassette\u003c\/a\u003e\u003c\/li\u003e\n\u003cli class=\"hvx-li\"\u003e\u003ca class=\"hvx-link\" href=\"https:\/\/portal.aciq.com\/media\/pdf\/ACiQ-SZ-ZPL-Sub-12W-HH-MD-12ZPL-HP230C-053124.pdf\" target=\"_blank\" rel=\"noopener\"\u003eSubmittal with 12k Wall Mount\u003c\/a\u003e\u003c\/li\u003e\n\u003cli class=\"hvx-li\"\u003e\u003ca class=\"hvx-link\" href=\"https:\/\/portal.aciq.com\/media\/pdf\/ACiQ-EHSZ-Nominal-Capacity-Performance-Charts-090325(Combined-All-AH).pdf\" target=\"_blank\" rel=\"noopener\"\u003eNominal Capacity Performance Charts\u003c\/a\u003e\u003c\/li\u003e\n\u003cli class=\"hvx-li\"\u003e\u003ca class=\"hvx-link\" href=\"https:\/\/portal.aciq.com\/media\/pdf\/ACiQ-CC-Sub-12CC-MC-063024(AH-Only).pdf\" target=\"_blank\" rel=\"noopener\"\u003eSubmittal\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n      \u003c\/div\u003e\n    \n      \u003cdiv class=\"hvx-desc-card\"\u003e\n        \u003ch2 class=\"hvx-section-title\"\u003eWarranty\u003c\/h2\u003e\n        \u003cul class=\"hvx-list\"\u003e\n\u003cli class=\"hvx-li\"\u003e\u003ca class=\"hvx-link\" href=\"https:\/\/portal.aciq.com\/media\/pdf\/aciq-mini-split-HES-warranty-12YR-Edit-2-8-4-2-1.pdf\" target=\"_blank\" rel=\"noopener\"\u003eWarranty\u003c\/a\u003e\u003c\/li\u003e\n\u003cli class=\"hvx-li\"\u003e\u003ca class=\"hvx-link\" href=\"https:\/\/portal.aciq.com\/media\/pdf\/aciq-warranty-12YR-Edit%202-8.pdf\" target=\"_blank\" rel=\"noopener\"\u003eWarranty Information\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n      \u003c\/div\u003e\n    \n\u003c\/div\u003e","brand":"ACIQ","offers":[{"title":"No installation","offer_id":42561278050347,"sku":"ACIQ-12ZPL-HP230C + ACIQ-12CC-HH-MC","price":1999.99,"currency_code":"USD","in_stock":true},{"title":"15FT","offer_id":42561278083115,"sku":"ACIQ-12ZPL-HP230C + ACIQ-12CC-HH-MC + 201813","price":2185.83,"currency_code":"USD","in_stock":true},{"title":"30FT","offer_id":42561278115883,"sku":"ACIQ-12ZPL-HP230C + ACIQ-12CC-HH-MC + 216740","price":2287.78,"currency_code":"USD","in_stock":true},{"title":"50FT","offer_id":42561278148651,"sku":"ACIQ-12ZPL-HP230C + ACIQ-12CC-HH-MC + 366396","price":2389.98,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0625\/5647\/1339\/files\/image_4__1.png?v=1765476703"},{"product_id":"cooper-hunter-12-000-btu-dip-switch-9k-12k-hyper-pro-single-zone-four-way-ceiling-cassette-w-refrigerant-humidity-sensor-minisplit-heat-pump-system-r454b-230v","title":"Cooper\u0026Hunter 12,000 BTU Dip Switch (9k-12k) Hyper Pro Single Zone Four-Way Ceiling Cassette w\/ Refrigerant \u0026 Humidity Sensor Minisplit Heat Pump System R454B 230V","description":"\u003cstyle\u003e\n    :root{\n      --hvx-golden:#FAA819; --hvx-slate:#262626; --hvx-ivory:#F4F1E6; --hvx-border:#e2e0d5; --hvx-card-bg:#ffffff;\n    }\n    .hvx-desc{background:var(--hvx-ivory); padding:18px; border-radius:18px; font-family:\"Articulat CF\",system-ui,-apple-system,Segoe UI,Roboto,Arial,sans-serif; color:#111;}\n    .hvx-desc-header{background:linear-gradient(120deg,var(--hvx-golden),var(--hvx-slate)); border-radius:16px; padding:16px 16px 14px; color:#fff; margin-bottom:14px;}\n    .hvx-eyebrow{font-size:12px; letter-spacing:.12em; text-transform:uppercase; opacity:.9; margin:0 0 6px;}\n    .hvx-title{font-family:\"Anton\",Impact,Haettenschweiler,\"Arial Narrow Bold\",sans-serif; font-size:26px; line-height:1.05; margin:0;}\n    .hvx-desc-card{background:var(--hvx-card-bg); border:1px solid var(--hvx-border); border-radius:16px; padding:14px; margin:12px 0; box-shadow:0 10px 18px rgba(0,0,0,.06);}\n    .hvx-section-title{margin:0 0 10px; font-size:13px; letter-spacing:.12em; text-transform:uppercase; display:inline-block; padding-bottom:6px; position:relative;}\n    .hvx-section-title:after{content:\"\"; position:absolute; left:0; bottom:0; height:3px; width:100%; border-radius:99px; background:linear-gradient(90deg,var(--hvx-golden),var(--hvx-slate));}\n    .hvx-badges{display:flex; flex-wrap:wrap; gap:8px; margin:6px 0 10px;}\n    .hvx-badge{display:inline-flex; align-items:center; gap:6px; padding:6px 10px; border-radius:999px; border:1px solid var(--hvx-border); background:#fff; font-size:12px; font-weight:600;}\n    .hvx-grid{display:grid; grid-template-columns:repeat(3,minmax(0,1fr)); gap:10px;}\n    .hvx-kv{border:1px solid var(--hvx-border); border-radius:14px; padding:10px; background:#fff;}\n    .hvx-k{font-size:12px; letter-spacing:.08em; text-transform:uppercase; color:#333; margin:0 0 6px;}\n    .hvx-v{font-size:14px; font-weight:700; margin:0;}\n    .hvx-table-wrap{overflow:auto; border-radius:14px; border:1px solid var(--hvx-border); background:#fff;}\n    table.hvx-table{width:100%; border-collapse:collapse; min-width:520px;}\n    .hvx-table th,.hvx-table td{padding:10px 12px; border-bottom:1px solid var(--hvx-border); vertical-align:top; font-size:14px;}\n    .hvx-table th{background:rgba(250,168,25,.12); text-align:left; font-size:12px; letter-spacing:.1em; text-transform:uppercase;}\n    .hvx-table tr:last-child td{border-bottom:none;}\n    .hvx-link{color:#111; text-decoration:none; border-bottom:2px solid rgba(250,168,25,.7);}\n    .hvx-link:hover{border-bottom-color:#111;}\n    .hvx-faq details{border:1px solid var(--hvx-border); border-radius:14px; background:#fff; padding:10px 12px; margin:10px 0;}\n    .hvx-faq summary{cursor:pointer; font-weight:800;}\n    .hvx-muted{color:#333; margin:6px 0 0;}\n    @media (max-width:720px){ .hvx-grid{grid-template-columns:1fr;} .hvx-title{font-size:24px;} }\n  \u003c\/style\u003e\n\u003cdiv class=\"hvx-desc\"\u003e\n\u003cdiv class=\"hvx-desc-header\"\u003e\n\u003cp class=\"hvx-eyebrow\"\u003eSingle Zone • 4-Way Ceiling Cassette • R454B • 208–230V\u003c\/p\u003e\n\u003ch2 class=\"hvx-title\"\u003eCooper\u0026amp;Hunter 12,000 BTU Dip Switch (9k-12k) Hyper Pro Single Zone Four-Way Ceiling Cassette w\/ Refrigerant \u0026amp; Humidity Sensor Minisplit Heat Pump System R454B 230V\u003c\/h2\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"hvx-desc-card\"\u003e\n\u003ch3 class=\"hvx-section-title\"\u003eOverview\u003c\/h3\u003e\n\u003cp class=\"hvx-muted\"\u003eA four-way ceiling cassette setup built for clean air delivery, even airflow, and smart control. The CH-RSH09-12MCT indoor cassette supports capacity selection (9K–12K class) via dip switch, and adds advanced monitoring features. Paired here with the CH-RHP12-230VO Hyper outdoor unit for strong cold-weather performance.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"hvx-desc-card\"\u003e\n\u003ch3 class=\"hvx-section-title\"\u003eHighlights\u003c\/h3\u003e\n\u003cdiv class=\"hvx-badges\"\u003e\n\u003cspan class=\"hvx-badge\"\u003eR454B Refrigerant\u003c\/span\u003e \u003cspan class=\"hvx-badge\"\u003e360° Airflow Panel\u003c\/span\u003e \u003cspan class=\"hvx-badge\"\u003eHumidity + Leak Detection (RSH)\u003c\/span\u003e \u003cspan class=\"hvx-badge\"\u003eGoldFin Coil Coating\u003c\/span\u003e \u003cspan class=\"hvx-badge\"\u003eBuilt-In Condensate Pump\u003c\/span\u003e \u003cspan class=\"hvx-badge\"\u003eSmart Kit Ready\u003c\/span\u003e\n\u003c\/div\u003e\n\u003cul style=\"margin: 0 0 10px; padding-left: 18px;\" class=\"hvx-muted\"\u003e\n\u003cli\u003eOmni-directional airflow with 360° panel for even room coverage.\u003c\/li\u003e\n\u003cli\u003eActivated carbon filtration support for fresher indoor air.\u003c\/li\u003e\n\u003cli\u003eAnti-cold-air heating behavior to reduce uncomfortable drafts.\u003c\/li\u003e\n\u003cli\u003eQuiet built-in pump with float switch (20.9\" lift) for condensate removal.\u003c\/li\u003e\n\u003cli\u003eTurbo operation, sleep mode, and multiple fan speeds for comfort tuning.\u003c\/li\u003e\n\u003cli\u003eHyper outdoor unit supports low-ambient heating down to -22°F.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cdiv class=\"hvx-grid\"\u003e\n\u003cdiv class=\"hvx-kv\"\u003e\n\u003cp class=\"hvx-k\"\u003eIndoor Model\u003c\/p\u003e\n\u003cp class=\"hvx-v\"\u003e\u003ca href=\"https:\/\/hvacsupplies.com\/search?options%5Bprefix%5D=last\u0026amp;q=CH-RSH09-12MCT\" class=\"hvx-link\"\u003eCH-RSH09-12MCT\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"hvx-kv\"\u003e\n\u003cp class=\"hvx-k\"\u003eOutdoor Model\u003c\/p\u003e\n\u003cp class=\"hvx-v\"\u003e\u003ca href=\"https:\/\/hvacsupplies.com\/search?options%5Bprefix%5D=last\u0026amp;q=CH-RHP12-230VO\" class=\"hvx-link\"\u003eCH-RHP12-230VO\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"hvx-kv\"\u003e\n\u003cp class=\"hvx-k\"\u003eLine Set Size\u003c\/p\u003e\n\u003cp class=\"hvx-v\"\u003e1\/4\" Liquid • 3\/8\" Gas\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"hvx-kv\"\u003e\n\u003cp class=\"hvx-k\"\u003ePower\u003c\/p\u003e\n\u003cp class=\"hvx-v\"\u003e208–230V • 1Ph • 60Hz\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"hvx-kv\"\u003e\n\u003cp class=\"hvx-k\"\u003eOutdoor Max Line Length\u003c\/p\u003e\n\u003cp class=\"hvx-v\"\u003e82 ft\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"hvx-kv\"\u003e\n\u003cp class=\"hvx-k\"\u003eLow-Ambient Heating\u003c\/p\u003e\n\u003cp class=\"hvx-v\"\u003eDown to -22°F\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"hvx-desc-card\"\u003e\n\u003ch3 class=\"hvx-section-title\"\u003eWhat’s Included\u003c\/h3\u003e\n\u003cul style=\"margin: 0; padding-left: 18px;\" class=\"hvx-muted\"\u003e\n\u003cli\u003eIndoor 4-way ceiling cassette: CH-RSH09-12MCT\u003c\/li\u003e\n\u003cli\u003eOutdoor condenser: CH-RHP12-230VO (Hyper)\u003c\/li\u003e\n\u003cli\u003eRemote control (indoor control package)\u003c\/li\u003e\n\u003cli\u003eCeiling Cassette Panel\u003c\/li\u003e\n\u003cli\u003eBuilt-in condensate pump with float switch (indoor)\u003c\/li\u003e\n\u003cli\u003eSmart Kit capability for app control (setup required)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"hvx-desc-card\"\u003e\n\u003ch3 class=\"hvx-section-title\"\u003eIndoor Specs (CH-RSH09-12MCT)\u003c\/h3\u003e\n\u003cdiv class=\"hvx-table-wrap\"\u003e\n\u003ctable class=\"hvx-table\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eSpec\u003c\/th\u003e\n\u003cth\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRefrigerant Type\u003c\/td\u003e\n\u003ctd\u003eR454B\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSystem Type\u003c\/td\u003e\n\u003ctd\u003eSingle Zone\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated Capacity\u003c\/td\u003e\n\u003ctd\u003e12,000 BTU class (dip-switch capacity selection model)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower\u003c\/td\u003e\n\u003ctd\u003e208–230V • 1Ph • 60Hz (Voltage Range: 187–253V)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSEER2 \/ EER2\u003c\/td\u003e\n\u003ctd\u003e22.2 \/ 12.5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDehumidification\u003c\/td\u003e\n\u003ctd\u003e3.07 pints\/day\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIndoor Airflow (CFM)\u003c\/td\u003e\n\u003ctd\u003e417.9 \/ 364.9 \/ 306.1 \/ 194.2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNoise (dB(A))\u003c\/td\u003e\n\u003ctd\u003e43.5 \/ 40.5 \/ 27.5 (H\/M\/L)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUnit Dimensions (W×D×H)\u003c\/td\u003e\n\u003ctd\u003e22.44 × 22.44 × 9.65 in\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNet \/ Gross Weight\u003c\/td\u003e\n\u003ctd\u003e35.27 \/ 41.89 lb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRefrigerant Piping\u003c\/td\u003e\n\u003ctd\u003e1\/4\" Liquid • 3\/8\" Gas\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDrain Pipe Diameter\u003c\/td\u003e\n\u003ctd\u003e1\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Range\u003c\/td\u003e\n\u003ctd\u003eCooling: 60–90°F • Heating: 32–86°F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"hvx-desc-card\"\u003e\n\u003ch3 class=\"hvx-section-title\"\u003eOutdoor Specs (CH-RHP12-230VO)\u003c\/h3\u003e\n\u003cdiv class=\"hvx-table-wrap\"\u003e\n\u003ctable class=\"hvx-table\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eSpec\u003c\/th\u003e\n\u003cth\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRefrigerant Type\u003c\/td\u003e\n\u003ctd\u003eR454B\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated Capacity\u003c\/td\u003e\n\u003ctd\u003e12,000 BTU\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCooling Capacity (Min–Max)\u003c\/td\u003e\n\u003ctd\u003e12,000 (3,800–14,600) BTU\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHeating Capacity (Min–Max)\u003c\/td\u003e\n\u003ctd\u003e12,000 (3,800–16,000) BTU\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower\u003c\/td\u003e\n\u003ctd\u003e208–230V • 1Ph • 60Hz (Voltage Range: 187–253V)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHSPF2 (Region IV \/ V)\u003c\/td\u003e\n\u003ctd\u003e10.5 \/ 8.0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCOP\u003c\/td\u003e\n\u003ctd\u003e3.76\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax Pipe Length\u003c\/td\u003e\n\u003ctd\u003e82 ft\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax Height Difference\u003c\/td\u003e\n\u003ctd\u003e49.2 ft\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMinimum Circuit Ampacity\u003c\/td\u003e\n\u003ctd\u003e15 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax Fuse\u003c\/td\u003e\n\u003ctd\u003e15 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutdoor Airflow\u003c\/td\u003e\n\u003ctd\u003e1,470.6 CFM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutdoor Noise\u003c\/td\u003e\n\u003ctd\u003e56 dB(A)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUnit Dimensions (W×D×H)\u003c\/td\u003e\n\u003ctd\u003e31.69 × 12.99 × 21.81 in\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNet \/ Gross Weight\u003c\/td\u003e\n\u003ctd\u003e72.75 \/ 78.70 lb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAmbient Temperature\u003c\/td\u003e\n\u003ctd\u003eCooling: -22–122°F • Heating: -22–75°F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAdditional Charge\u003c\/td\u003e\n\u003ctd\u003e0.16 oz\/ft (1\/4\" liquid line)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"hvx-desc-card\"\u003e\n\u003ch3 class=\"hvx-section-title\"\u003eDocuments \u0026amp; Downloads\u003c\/h3\u003e\n\u003cul style=\"margin: 0; padding-left: 18px;\" class=\"hvx-muted\"\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/media.cooperandhunter.us\/4118\/Installation-Manual-R454B-Outdoor-units--.pdf\" class=\"hvx-link\"\u003eOutdoor Units Installation Manual (R454B)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/media.cooperandhunter.us\/4200\/SlimDuct-Leaflet-R454B.pdf\" class=\"hvx-link\"\u003eSlimDuct Leaflet (R454B)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/media.cooperandhunter.us\/4654\/Installation-manual-R454B-Ceiling-cassette_compressed.pdf\" class=\"hvx-link\"\u003eCeiling Cassette Installation Manual (R454B)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/media.cooperandhunter.us\/4655\/Owners_-manual-R454B-Ceiling-cassette_compressed.pdf\" class=\"hvx-link\"\u003eCeiling Cassette Owner’s Manual (R454B)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/media.cooperandhunter.us\/4125\/120N-wire-controller---owners-manual.pdf\" class=\"hvx-link\"\u003e120N Wire Controller Owner’s Manual\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/media.cooperandhunter.us\/3198\/MultiZone-Combination-HYPER.pdf\" class=\"hvx-link\"\u003eMultiZone Combination Guide — Hyper\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/media.cooperandhunter.us\/3199\/MultiZone-Combination-Regular.pdf\" class=\"hvx-link\"\u003eMultiZone Combination Guide — Regular\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/media.cooperandhunter.us\/4170\/CH-RHP12-230VO-%2B-CH-RH12MASTWM-230VI.pdf\" class=\"hvx-link\"\u003eSubmittal Sheet: CH-RHP12-230VO + CH-RH12MASTWM-230VI\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/media.cooperandhunter.us\/4203\/CH-RHP12-230VO-%2B-CH-RS06-12MDT--MS.pdf\" class=\"hvx-link\"\u003eSubmittal Sheet: CH-RHP12-230VO + CH-RS06-12MDT\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"hvx-desc-card\"\u003e\n\u003ch3 class=\"hvx-section-title\"\u003eImportant\u003c\/h3\u003e\n\u003cul style=\"margin: 0; padding-left: 18px;\" class=\"hvx-muted\"\u003e\n\u003cli\u003eProfessional installation is recommended.\u003c\/li\u003e\n\u003cli\u003eVerify electrical requirements: 208–230V dedicated circuit sized per nameplate\/MCA.\u003c\/li\u003e\n\u003cli\u003eUse correct line set sizing: 1\/4\" liquid and 3\/8\" suction.\u003c\/li\u003e\n\u003cli\u003eFor help choosing equipment, contact us: \u003ca href=\"https:\/\/hvacsupplies.com\/pages\/contact\" class=\"hvx-link\"\u003ehvacsupplies.com\/pages\/contact\u003c\/a\u003e • \u003ca href=\"tel:+18005438933\" class=\"hvx-link\"\u003e(800) 543-8933\u003c\/a\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"hvx-desc-card hvx-faq\"\u003e\n\u003ch3 class=\"hvx-section-title\"\u003eFAQs\u003c\/h3\u003e\n\u003cdetails open=\"\"\u003e\n\u003csummary\u003eDoes this cassette include a condensate pump?\u003c\/summary\u003e\n\u003cp class=\"hvx-muted\"\u003eYes. The indoor cassette includes a built-in pump with float switch (20.9\" lift).\u003c\/p\u003e\n\u003c\/details\u003e\n\u003cdetails open=\"\"\u003e\n\u003csummary\u003eCan I control it with an app?\u003c\/summary\u003e\n\u003cp class=\"hvx-muted\"\u003eSmart Kit capability supports app control through the C\u0026amp;H platform after setup.\u003c\/p\u003e\n\u003c\/details\u003e\n\u003cdetails open=\"\"\u003e\n\u003csummary\u003eWhat line set sizes are required?\u003c\/summary\u003e\n\u003cp class=\"hvx-muted\"\u003eThis cassette uses 1\/4\" liquid and 3\/8\" gas piping.\u003c\/p\u003e\n\u003c\/details\u003e\n\u003cdetails open=\"\"\u003e\n\u003csummary\u003eHow does the Hyper outdoor unit handle cold weather?\u003c\/summary\u003e\n\u003cp class=\"hvx-muted\"\u003eThe CH-RHP12-230VO supports heating operation down to -22°F ambient.\u003c\/p\u003e\n\u003c\/details\u003e\n\u003cdetails open=\"\"\u003e\n\u003csummary\u003eIs a wall thermostat required?\u003c\/summary\u003e\n\u003cp class=\"hvx-muted\"\u003eNo. The system supports remote control operation; wall thermostat options may be added if desired.\u003c\/p\u003e\n\u003c\/details\u003e\n\u003cdetails open=\"\"\u003e\n\u003csummary\u003eIs this single-zone only?\u003c\/summary\u003e\n\u003cp class=\"hvx-muted\"\u003eThis configuration is presented as single-zone pairing.\u003c\/p\u003e\n\u003c\/details\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e","brand":"Cooper\u0026Hunter","offers":[{"title":"No Installation","offer_id":42690630516779,"sku":"CH-RSH09-12MCT + CH-RHP12-230VO","price":2107.06,"currency_code":"USD","in_stock":true},{"title":"16FT","offer_id":42690630549547,"sku":"CH-RSH09-12MCT + CH-RHP12-230VO","price":2288.5,"currency_code":"USD","in_stock":true},{"title":"25FT","offer_id":42690630582315,"sku":"CH-RSH09-12MCT + CH-RHP12-230VO","price":2334.58,"currency_code":"USD","in_stock":true},{"title":"50FT","offer_id":42690630615083,"sku":"CH-RSH09-12MCT + CH-RHP12-230VO","price":2577.94,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0625\/5647\/1339\/files\/2-ZoneDuctlessMiniSplitAC_HeatPump48000BTU_26.png?v=1769199192"},{"product_id":"cooper-hunter-12-000-btu-dip-switch-9k-12k-pro-single-zone-four-way-ceiling-cassette-w-refrigerant-humidity-sensor-minisplit-heat-pump-system-r454b-230v","title":"Cooper\u0026Hunter 12,000 BTU Dip Switch (9k-12k) Pro Single Zone Four-Way Ceiling Cassette w\/ Refrigerant \u0026 Humidity Sensor Minisplit Heat Pump System R454B 230V","description":"\u003cstyle\u003e\n    :root{--hvx-golden:#FAA819; --hvx-slate:#262626; --hvx-ivory:#F4F1E6; --hvx-border:#e2e0d5; --hvx-card-bg:#ffffff;}\n    .hvx-desc{background:var(--hvx-ivory); padding:18px; border-radius:18px; font-family:\"Articulat CF\",system-ui,-apple-system,Segoe UI,Roboto,Arial,sans-serif; color:#111;}\n    .hvx-desc-header{background:linear-gradient(120deg,var(--hvx-golden),var(--hvx-slate)); border-radius:16px; padding:16px 16px 14px; color:#fff; margin-bottom:14px;}\n    .hvx-eyebrow{font-size:12px; letter-spacing:.12em; text-transform:uppercase; opacity:.9; margin:0 0 6px;}\n    .hvx-title{font-family:\"Anton\",Impact,Haettenschweiler,\"Arial Narrow Bold\",sans-serif; font-size:26px; line-height:1.05; margin:0;}\n    .hvx-desc-card{background:var(--hvx-card-bg); border:1px solid var(--hvx-border); border-radius:16px; padding:14px; margin:12px 0; box-shadow:0 10px 18px rgba(0,0,0,.06);}\n    .hvx-section-title{margin:0 0 10px; font-size:13px; letter-spacing:.12em; text-transform:uppercase; display:inline-block; padding-bottom:6px; position:relative;}\n    .hvx-section-title:after{content:\"\"; position:absolute; left:0; bottom:0; height:3px; width:100%; border-radius:99px; background:linear-gradient(90deg,var(--hvx-golden),var(--hvx-slate));}\n    .hvx-badges{display:flex; flex-wrap:wrap; gap:8px; margin:6px 0 10px;}\n    .hvx-badge{display:inline-flex; align-items:center; gap:6px; padding:6px 10px; border-radius:999px; border:1px solid var(--hvx-border); background:#fff; font-size:12px; font-weight:600;}\n    .hvx-grid{display:grid; grid-template-columns:repeat(3,minmax(0,1fr)); gap:10px;}\n    .hvx-kv{border:1px solid var(--hvx-border); border-radius:14px; padding:10px; background:#fff;}\n    .hvx-k{font-size:12px; letter-spacing:.08em; text-transform:uppercase; color:#333; margin:0 0 6px;}\n    .hvx-v{font-size:14px; font-weight:700; margin:0;}\n    .hvx-table-wrap{overflow:auto; border-radius:14px; border:1px solid var(--hvx-border); background:#fff;}\n    table.hvx-table{width:100%; border-collapse:collapse; min-width:520px;}\n    .hvx-table th,.hvx-table td{padding:10px 12px; border-bottom:1px solid var(--hvx-border); vertical-align:top; font-size:14px;}\n    .hvx-table th{background:rgba(250,168,25,.12); text-align:left; font-size:12px; letter-spacing:.1em; text-transform:uppercase;}\n    .hvx-table tr:last-child td{border-bottom:none;}\n    .hvx-link{color:#111; text-decoration:none; border-bottom:2px solid rgba(250,168,25,.7);}\n    .hvx-link:hover{border-bottom-color:#111;}\n    .hvx-faq details{border:1px solid var(--hvx-border); border-radius:14px; background:#fff; padding:10px 12px; margin:10px 0;}\n    .hvx-faq summary{cursor:pointer; font-weight:800;}\n    .hvx-muted{color:#333; margin:6px 0 0;}\n    @media (max-width:720px){ .hvx-grid{grid-template-columns:1fr;} .hvx-title{font-size:24px;} }\n  \u003c\/style\u003e\n\u003cdiv class=\"hvx-desc\"\u003e\n\u003cdiv class=\"hvx-desc-header\"\u003e\n\u003cp class=\"hvx-eyebrow\"\u003eSingle Zone • 4-Way Ceiling Cassette • R454B • 208–230V\u003c\/p\u003e\n\u003ch2 class=\"hvx-title\"\u003eCooper\u0026amp;Hunter 12,000 BTU Dip Switch (9k-12k) Pro Single Zone Four-Way Ceiling Cassette w\/ Refrigerant \u0026amp; Humidity Sensor Minisplit Heat Pump System R454B 230V\u003c\/h2\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"hvx-desc-card\"\u003e\n\u003ch3 class=\"hvx-section-title\"\u003eOverview\u003c\/h3\u003e\n\u003cp class=\"hvx-muted\"\u003eA four-way ceiling cassette configuration designed for strong airflow distribution, clean-air support, and smart control options. The CH-RSH09-12MCT indoor cassette supports dip-switch capacity selection (9K–12K class) and adds advanced monitoring features. Paired here with the CH-RES12-230VO regular outdoor unit for efficient, dependable heating and cooling.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"hvx-desc-card\"\u003e\n\u003ch3 class=\"hvx-section-title\"\u003eHighlights\u003c\/h3\u003e\n\u003cdiv class=\"hvx-badges\"\u003e\n\u003cspan class=\"hvx-badge\"\u003eR454B Refrigerant\u003c\/span\u003e \u003cspan class=\"hvx-badge\"\u003e360° Airflow Panel\u003c\/span\u003e \u003cspan class=\"hvx-badge\"\u003eHumidity + Leak Detection (RSH)\u003c\/span\u003e \u003cspan class=\"hvx-badge\"\u003eGoldFin Coil Coating\u003c\/span\u003e \u003cspan class=\"hvx-badge\"\u003eBuilt-In Condensate Pump\u003c\/span\u003e \u003cspan class=\"hvx-badge\"\u003eInverter Outdoor\u003c\/span\u003e\n\u003c\/div\u003e\n\u003cul class=\"hvx-muted\" style=\"margin: 0 0 10px; padding-left: 18px;\"\u003e\n\u003cli\u003eOmni-directional airflow with 360° panel for even room coverage.\u003c\/li\u003e\n\u003cli\u003eActivated carbon filtration support for fresher indoor air.\u003c\/li\u003e\n\u003cli\u003eAnti-cold-air heating behavior to reduce drafts.\u003c\/li\u003e\n\u003cli\u003eQuiet built-in pump with float switch (20.9\" lift) for condensate removal.\u003c\/li\u003e\n\u003cli\u003eTurbo operation, sleep mode, and multiple fan speeds.\u003c\/li\u003e\n\u003cli\u003eRegular outdoor unit supports low-ambient heating down to -13°F.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cdiv class=\"hvx-grid\"\u003e\n\u003cdiv class=\"hvx-kv\"\u003e\n\u003cp class=\"hvx-k\"\u003eIndoor Model\u003c\/p\u003e\n\u003cp class=\"hvx-v\"\u003e\u003ca class=\"hvx-link\" href=\"https:\/\/hvacsupplies.com\/search?options%5Bprefix%5D=last\u0026amp;q=CH-RSH09-12MCT\"\u003eCH-RSH09-12MCT\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"hvx-kv\"\u003e\n\u003cp class=\"hvx-k\"\u003eOutdoor Model\u003c\/p\u003e\n\u003cp class=\"hvx-v\"\u003e\u003ca class=\"hvx-link\" href=\"https:\/\/hvacsupplies.com\/search?options%5Bprefix%5D=last\u0026amp;q=CH-RES12-230VO\"\u003eCH-RES12-230VO\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"hvx-kv\"\u003e\n\u003cp class=\"hvx-k\"\u003eLine Set Size\u003c\/p\u003e\n\u003cp class=\"hvx-v\"\u003e1\/4\" Liquid • 3\/8\" Gas\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"hvx-kv\"\u003e\n\u003cp class=\"hvx-k\"\u003eSEER2\u003c\/p\u003e\n\u003cp class=\"hvx-v\"\u003e21.1\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"hvx-kv\"\u003e\n\u003cp class=\"hvx-k\"\u003eOutdoor Max Line Length\u003c\/p\u003e\n\u003cp class=\"hvx-v\"\u003e82 ft\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"hvx-kv\"\u003e\n\u003cp class=\"hvx-k\"\u003eLow-Ambient Heating\u003c\/p\u003e\n\u003cp class=\"hvx-v\"\u003eDown to -13°F\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"hvx-desc-card\"\u003e\n\u003ch3 class=\"hvx-section-title\"\u003eWhat’s Included\u003c\/h3\u003e\n\u003cul class=\"hvx-muted\" style=\"margin: 0; padding-left: 18px;\"\u003e\n\u003cli\u003eIndoor 4-way ceiling cassette: CH-RSH09-12MCT\u003c\/li\u003e\n\u003cli\u003eOutdoor condenser: CH-RES12-230VO (Regular)\u003c\/li\u003e\n\u003cli\u003eRemote control (indoor control package)\u003c\/li\u003e\n\u003cli\u003eCeiling Cassette Panel\u003c\/li\u003e\n\u003cli\u003eBuilt-in condensate pump with float switch (indoor)\u003c\/li\u003e\n\u003cli\u003eSmart Kit capability for app control (setup required)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"hvx-desc-card\"\u003e\n\u003ch3 class=\"hvx-section-title\"\u003eIndoor Specs (CH-RSH09-12MCT)\u003c\/h3\u003e\n\u003cdiv class=\"hvx-table-wrap\"\u003e\n\u003ctable class=\"hvx-table\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eSpec\u003c\/th\u003e\n\u003cth\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRefrigerant Type\u003c\/td\u003e\n\u003ctd\u003eR454B\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSystem Type\u003c\/td\u003e\n\u003ctd\u003eSingle Zone\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated Capacity\u003c\/td\u003e\n\u003ctd\u003e12,000 BTU class (dip-switch capacity selection model)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower\u003c\/td\u003e\n\u003ctd\u003e208–230V • 1Ph • 60Hz (Voltage Range: 187–253V)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSEER2 \/ EER2\u003c\/td\u003e\n\u003ctd\u003e22.2 \/ 12.5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDehumidification\u003c\/td\u003e\n\u003ctd\u003e3.07 pints\/day\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIndoor Airflow (CFM)\u003c\/td\u003e\n\u003ctd\u003e417.9 \/ 364.9 \/ 306.1 \/ 194.2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNoise (dB(A))\u003c\/td\u003e\n\u003ctd\u003e43.5 \/ 40.5 \/ 27.5 (H\/M\/L)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUnit Dimensions (W×D×H)\u003c\/td\u003e\n\u003ctd\u003e22.44 × 22.44 × 9.65 in\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNet \/ Gross Weight\u003c\/td\u003e\n\u003ctd\u003e35.27 \/ 41.89 lb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRefrigerant Piping\u003c\/td\u003e\n\u003ctd\u003e1\/4\" Liquid • 3\/8\" Gas\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDrain Pipe Diameter\u003c\/td\u003e\n\u003ctd\u003e1\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Range\u003c\/td\u003e\n\u003ctd\u003eCooling: 60–90°F • Heating: 32–86°F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"hvx-desc-card\"\u003e\n\u003ch3 class=\"hvx-section-title\"\u003eOutdoor Specs (CH-RES12-230VO)\u003c\/h3\u003e\n\u003cdiv class=\"hvx-table-wrap\"\u003e\n\u003ctable class=\"hvx-table\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eSpec\u003c\/th\u003e\n\u003cth\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRefrigerant Type\u003c\/td\u003e\n\u003ctd\u003eR454B\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated Capacity\u003c\/td\u003e\n\u003ctd\u003e12,000 BTU\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCooling Capacity (Min–Max)\u003c\/td\u003e\n\u003ctd\u003e11,500 (3,100–13,000) BTU\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHeating Capacity (Min–Max)\u003c\/td\u003e\n\u003ctd\u003e12,000 (3,700–15,600) BTU\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower\u003c\/td\u003e\n\u003ctd\u003e208–230V • 1Ph • 60Hz (Voltage Range: 187–253V)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSEER2 \/ EER2\u003c\/td\u003e\n\u003ctd\u003e19 \/ 11.7\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHSPF2 (Region IV \/ V)\u003c\/td\u003e\n\u003ctd\u003e10.2 \/ 8.0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCOP\u003c\/td\u003e\n\u003ctd\u003e3.42\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax Pipe Length\u003c\/td\u003e\n\u003ctd\u003e82 ft\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax Height Difference\u003c\/td\u003e\n\u003ctd\u003e49.2 ft\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMinimum Circuit Ampacity\u003c\/td\u003e\n\u003ctd\u003e12 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax Fuse\u003c\/td\u003e\n\u003ctd\u003e15 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutdoor Airflow\u003c\/td\u003e\n\u003ctd\u003e1,236.1 CFM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutdoor Noise\u003c\/td\u003e\n\u003ctd\u003e55.5 dB(A)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUnit Dimensions (W×D×H)\u003c\/td\u003e\n\u003ctd\u003e30.12 × 11.93 × 21.85 in\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNet \/ Gross Weight\u003c\/td\u003e\n\u003ctd\u003e62.17 \/ 67.68 lb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAmbient Temperature\u003c\/td\u003e\n\u003ctd\u003eCooling: -13–122°F • Heating: -13–75°F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAdditional Charge\u003c\/td\u003e\n\u003ctd\u003e0.16 oz\/ft (1\/4\" liquid line)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"hvx-desc-card\"\u003e\n\u003ch3 class=\"hvx-section-title\"\u003eDocuments \u0026amp; Downloads\u003c\/h3\u003e\n\u003cul class=\"hvx-muted\" style=\"margin: 0; padding-left: 18px;\"\u003e\n\u003cli\u003e\u003ca class=\"hvx-link\" href=\"https:\/\/media.cooperandhunter.us\/4118\/Installation-Manual-R454B-Outdoor-units--.pdf\"\u003eOutdoor Units Installation Manual (R454B)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca class=\"hvx-link\" href=\"https:\/\/media.cooperandhunter.us\/4200\/SlimDuct-Leaflet-R454B.pdf\"\u003eSlimDuct Leaflet (R454B)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca class=\"hvx-link\" href=\"https:\/\/media.cooperandhunter.us\/4654\/Installation-manual-R454B-Ceiling-cassette_compressed.pdf\"\u003eCeiling Cassette Installation Manual (R454B)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca class=\"hvx-link\" href=\"https:\/\/media.cooperandhunter.us\/4655\/Owners_-manual-R454B-Ceiling-cassette_compressed.pdf\"\u003eCeiling Cassette Owner’s Manual (R454B)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca class=\"hvx-link\" href=\"https:\/\/media.cooperandhunter.us\/4125\/120N-wire-controller---owners-manual.pdf\"\u003e120N Wire Controller Owner’s Manual\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca class=\"hvx-link\" href=\"https:\/\/media.cooperandhunter.us\/3198\/MultiZone-Combination-HYPER.pdf\"\u003eMultiZone Combination Guide — Hyper\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca class=\"hvx-link\" href=\"https:\/\/media.cooperandhunter.us\/3199\/MultiZone-Combination-Regular.pdf\"\u003eMultiZone Combination Guide — Regular\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca class=\"hvx-link\" href=\"https:\/\/media.cooperandhunter.us\/4156\/CH-RES12-230VO-%2B-CH-PRO12MASTWM-230VI.pdf\"\u003eSubmittal Sheet: CH-RES12-230VO + CH-PRO12MASTWM-230VI\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca class=\"hvx-link\" href=\"https:\/\/media.cooperandhunter.us\/4169\/CH-RES12-230VO-%2B-CH-RH12MASTWM-230VI.pdf\"\u003eSubmittal Sheet: CH-RES12-230VO + CH-RH12MASTWM-230VI\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca class=\"hvx-link\" href=\"https:\/\/media.cooperandhunter.us\/4210\/CH-RES12-230VO-%2B-CH-RS06-12MDT--MS.pdf\"\u003eSubmittal Sheet: CH-RES12-230VO + CH-RS06-12MDT\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca class=\"hvx-link\" href=\"https:\/\/media.cooperandhunter.us\/4677\/CH-RES12-230VO_CH-RSH12MCT.pdf\"\u003eSubmittal Sheet: CH-RES12-230VO + CH-RSH12MCT\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca class=\"hvx-link\" href=\"https:\/\/media.cooperandhunter.us\/4676\/CH-RES12-230VO_CH-RH12MCT.pdf\"\u003eSubmittal Sheet: CH-RES12-230VO + CH-RH12MCT\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"hvx-desc-card\"\u003e\n\u003ch3 class=\"hvx-section-title\"\u003eImportant\u003c\/h3\u003e\n\u003cul class=\"hvx-muted\" style=\"margin: 0; padding-left: 18px;\"\u003e\n\u003cli\u003eProfessional installation is recommended.\u003c\/li\u003e\n\u003cli\u003eVerify electrical requirements: 208–230V dedicated circuit sized per nameplate\/MCA.\u003c\/li\u003e\n\u003cli\u003eUse correct line set sizing: 1\/4\" liquid and 3\/8\" suction.\u003c\/li\u003e\n\u003cli\u003eFor help choosing equipment, contact us: \u003ca class=\"hvx-link\" href=\"https:\/\/hvacsupplies.com\/pages\/contact\"\u003ehvacsupplies.com\/pages\/contact\u003c\/a\u003e • \u003ca class=\"hvx-link\" href=\"tel:+18005438933\"\u003e(800) 543-8933\u003c\/a\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"hvx-desc-card hvx-faq\"\u003e\n\u003ch3 class=\"hvx-section-title\"\u003eFAQs\u003c\/h3\u003e\n\u003cdetails\u003e\n\u003csummary\u003eDoes this cassette include a condensate pump?\u003c\/summary\u003e\n\u003cp class=\"hvx-muted\"\u003eYes. The indoor cassette includes a built-in pump with float switch (20.9\" lift).\u003c\/p\u003e\n\u003c\/details\u003e\n\u003cdetails\u003e\n\u003csummary\u003eWhat line set sizes are required?\u003c\/summary\u003e\n\u003cp class=\"hvx-muted\"\u003eThis cassette uses 1\/4\" liquid and 3\/8\" gas piping.\u003c\/p\u003e\n\u003c\/details\u003e\n\u003cdetails\u003e\n\u003csummary\u003eHow cold can the regular outdoor unit operate in heating?\u003c\/summary\u003e\n\u003cp class=\"hvx-muted\"\u003eThe CH-RES12-230VO supports heating operation down to -13°F ambient.\u003c\/p\u003e\n\u003c\/details\u003e\n\u003cdetails\u003e\n\u003csummary\u003eCan I control it with an app?\u003c\/summary\u003e\n\u003cp class=\"hvx-muted\"\u003eSmart Kit capability supports app control through the C\u0026amp;H platform after setup.\u003c\/p\u003e\n\u003c\/details\u003e\n\u003cdetails\u003e\n\u003csummary\u003eIs a wall thermostat required?\u003c\/summary\u003e\n\u003cp class=\"hvx-muted\"\u003eNo. The system supports remote control operation; wall thermostat options may be added if desired.\u003c\/p\u003e\n\u003c\/details\u003e\n\u003cdetails\u003e\n\u003csummary\u003eIs this single-zone only?\u003c\/summary\u003e\n\u003cp class=\"hvx-muted\"\u003eThis configuration is presented as single-zone pairing.\u003c\/p\u003e\n\u003c\/details\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e","brand":"Cooper\u0026Hunter","offers":[{"title":"No Installation","offer_id":42690661875755,"sku":"CH-RSH09-12MCT + CH-RES12-230VO","price":1874.88,"currency_code":"USD","in_stock":true},{"title":"16FT","offer_id":42690661908523,"sku":"CH-RSH09-12MCT + CH-RES12-230VO","price":2056.32,"currency_code":"USD","in_stock":true},{"title":"25FT","offer_id":42690661941291,"sku":"CH-RSH09-12MCT + CH-RES12-230VO","price":2102.4,"currency_code":"USD","in_stock":true},{"title":"50FT","offer_id":42690661974059,"sku":"CH-RSH09-12MCT + CH-RES12-230VO","price":2345.76,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0625\/5647\/1339\/files\/FourWay_Regular_Product_Hero_48_33b3a9f5-7a1c-442f-a881-e51e604eb6c3.png?v=1769199174"},{"product_id":"cooper-hunter-12-000-btu-hyper-single-zone-four-way-ceiling-cassette-w-humidity-sensor-minisplit-heat-pump-system-r454b-230v","title":"Cooper\u0026Hunter 12,000 BTU Hyper Single Zone Four-Way Ceiling Cassette w\/ Humidity Sensor Minisplit Heat Pump System R454B 230V","description":"\u003cstyle\u003e\n    :root{--hvx-golden:#FAA819; --hvx-slate:#262626; --hvx-ivory:#F4F1E6; --hvx-border:#e2e0d5; --hvx-card-bg:#ffffff;}\n    .hvx-desc{background:var(--hvx-ivory); padding:18px; border-radius:18px; font-family:\"Articulat CF\",system-ui,-apple-system,Segoe UI,Roboto,Arial,sans-serif; color:#111;}\n    .hvx-desc-header{background:linear-gradient(120deg,var(--hvx-golden),var(--hvx-slate)); border-radius:16px; padding:16px 16px 14px; color:#fff; margin-bottom:14px;}\n    .hvx-eyebrow{font-size:12px; letter-spacing:.12em; text-transform:uppercase; opacity:.9; margin:0 0 6px;}\n    .hvx-title{font-family:\"Anton\",Impact,Haettenschweiler,\"Arial Narrow Bold\",sans-serif; font-size:26px; line-height:1.05; margin:0;}\n    .hvx-desc-card{background:var(--hvx-card-bg); border:1px solid var(--hvx-border); border-radius:16px; padding:14px; margin:12px 0; box-shadow:0 10px 18px rgba(0,0,0,.06);}\n    .hvx-section-title{margin:0 0 10px; font-size:13px; letter-spacing:.12em; text-transform:uppercase; display:inline-block; padding-bottom:6px; position:relative;}\n    .hvx-section-title:after{content:\"\"; position:absolute; left:0; bottom:0; height:3px; width:100%; border-radius:99px; background:linear-gradient(90deg,var(--hvx-golden),var(--hvx-slate));}\n    .hvx-badges{display:flex; flex-wrap:wrap; gap:8px; margin:6px 0 10px;}\n    .hvx-badge{display:inline-flex; align-items:center; gap:6px; padding:6px 10px; border-radius:999px; border:1px solid var(--hvx-border); background:#fff; font-size:12px; font-weight:600;}\n    .hvx-grid{display:grid; grid-template-columns:repeat(3,minmax(0,1fr)); gap:10px;}\n    .hvx-kv{border:1px solid var(--hvx-border); border-radius:14px; padding:10px; background:#fff;}\n    .hvx-k{font-size:12px; letter-spacing:.08em; text-transform:uppercase; color:#333; margin:0 0 6px;}\n    .hvx-v{font-size:14px; font-weight:700; margin:0;}\n    .hvx-table-wrap{overflow:auto; border-radius:14px; border:1px solid var(--hvx-border); background:#fff;}\n    table.hvx-table{width:100%; border-collapse:collapse; min-width:520px;}\n    .hvx-table th,.hvx-table td{padding:10px 12px; border-bottom:1px solid var(--hvx-border); vertical-align:top; font-size:14px;}\n    .hvx-table th{background:rgba(250,168,25,.12); text-align:left; font-size:12px; letter-spacing:.1em; text-transform:uppercase;}\n    .hvx-table tr:last-child td{border-bottom:none;}\n    .hvx-link{color:#111; text-decoration:none; border-bottom:2px solid rgba(250,168,25,.7);}\n    .hvx-link:hover{border-bottom-color:#111;}\n    .hvx-faq details{border:1px solid var(--hvx-border); border-radius:14px; background:#fff; padding:10px 12px; margin:10px 0;}\n    .hvx-faq summary{cursor:pointer; font-weight:800;}\n    .hvx-muted{color:#333; margin:6px 0 0;}\n    @media (max-width:720px){ .hvx-grid{grid-template-columns:1fr;} .hvx-title{font-size:24px;} }\n  \u003c\/style\u003e\n\u003cdiv class=\"hvx-desc\"\u003e\n\u003cdiv class=\"hvx-desc-header\"\u003e\n\u003cp class=\"hvx-eyebrow\"\u003eSingle Zone • 4-Way Ceiling Cassette • R454B • 208–230V\u003c\/p\u003e\n\u003ch2 class=\"hvx-title\"\u003eCooper\u0026amp;Hunter 12,000 BTU Hyper Single Zone Four-Way Ceiling Cassette w\/ Humidity Sensor Minisplit Heat Pump System R454B 230V\u003c\/h2\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"hvx-desc-card\"\u003e\n\u003ch3 class=\"hvx-section-title\"\u003eOverview\u003c\/h3\u003e\n\u003cp class=\"hvx-muted\"\u003eA 12K-class four-way ceiling cassette pairing built for even airflow, clean-air support, and convenient control. The CH-RH12MCT indoor cassette uses a 360° air flow panel and omni-directional delivery to cover the entire space. Paired here with the CH-RHP12-230VO Hyper outdoor unit for strong cold-weather heating down to -22°F.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"hvx-desc-card\"\u003e\n\u003ch3 class=\"hvx-section-title\"\u003eHighlights\u003c\/h3\u003e\n\u003cdiv class=\"hvx-badges\"\u003e\n\u003cspan class=\"hvx-badge\"\u003eR454B Refrigerant\u003c\/span\u003e \u003cspan class=\"hvx-badge\"\u003e360° Airflow Panel\u003c\/span\u003e \u003cspan class=\"hvx-badge\"\u003eHumidity Sensor\u003c\/span\u003e \u003cspan class=\"hvx-badge\"\u003eGoldFin Coil Coating\u003c\/span\u003e \u003cspan class=\"hvx-badge\"\u003eBuilt-In Condensate Pump\u003c\/span\u003e \u003cspan class=\"hvx-badge\"\u003eHyper Heating Outdoor\u003c\/span\u003e\n\u003c\/div\u003e\n\u003cul class=\"hvx-muted\" style=\"margin: 0 0 10px; padding-left: 18px;\"\u003e\n\u003cli\u003eOmni-directional airflow with 360° panel for even room coverage.\u003c\/li\u003e\n\u003cli\u003eActivated carbon filtration support for fresher indoor air.\u003c\/li\u003e\n\u003cli\u003eAnti-cold-air heating behavior to reduce drafts.\u003c\/li\u003e\n\u003cli\u003eQuiet built-in pump with float switch (20.9\" lift) for condensate removal.\u003c\/li\u003e\n\u003cli\u003eTurbo operation, sleep mode, and multiple fan speeds.\u003c\/li\u003e\n\u003cli\u003eHyper outdoor unit supports low-ambient heating down to -22°F.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cdiv class=\"hvx-grid\"\u003e\n\u003cdiv class=\"hvx-kv\"\u003e\n\u003cp class=\"hvx-k\"\u003eIndoor Model\u003c\/p\u003e\n\u003cp class=\"hvx-v\"\u003e\u003ca class=\"hvx-link\" href=\"https:\/\/hvacsupplies.com\/search?options%5Bprefix%5D=last\u0026amp;q=CH-RH12MCT\"\u003eCH-RH12MCT\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"hvx-kv\"\u003e\n\u003cp class=\"hvx-k\"\u003eOutdoor Model\u003c\/p\u003e\n\u003cp class=\"hvx-v\"\u003e\u003ca class=\"hvx-link\" href=\"https:\/\/hvacsupplies.com\/search?options%5Bprefix%5D=last\u0026amp;q=CH-RHP12-230VO\"\u003eCH-RHP12-230VO\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"hvx-kv\"\u003e\n\u003cp class=\"hvx-k\"\u003eLine Set Size\u003c\/p\u003e\n\u003cp class=\"hvx-v\"\u003e1\/4\" Liquid • 3\/8\" Gas\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"hvx-kv\"\u003e\n\u003cp class=\"hvx-k\"\u003eSEER2\u003c\/p\u003e\n\u003cp class=\"hvx-v\"\u003e22.2\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"hvx-kv\"\u003e\n\u003cp class=\"hvx-k\"\u003eOutdoor Max Line Length\u003c\/p\u003e\n\u003cp class=\"hvx-v\"\u003e82 ft\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"hvx-kv\"\u003e\n\u003cp class=\"hvx-k\"\u003eLow-Ambient Heating\u003c\/p\u003e\n\u003cp class=\"hvx-v\"\u003eDown to -22°F\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"hvx-desc-card\"\u003e\n\u003ch3 class=\"hvx-section-title\"\u003eWhat’s Included\u003c\/h3\u003e\n\u003cul class=\"hvx-muted\" style=\"margin: 0; padding-left: 18px;\"\u003e\n\u003cli\u003eIndoor 4-way ceiling cassette: CH-RH12MCT\u003c\/li\u003e\n\u003cli\u003eOutdoor condenser: CH-RHP12-230VO (Hyper)\u003c\/li\u003e\n\u003cli\u003eRemote control (indoor control package)\u003c\/li\u003e\n\u003cli\u003eCeiling Cassette Panel\u003c\/li\u003e\n\u003cli\u003eBuilt-in condensate pump with float switch (indoor)\u003c\/li\u003e\n\u003cli\u003eSmart Kit capability for app control (setup required)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"hvx-desc-card\"\u003e\n\u003ch3 class=\"hvx-section-title\"\u003eIndoor Specs (CH-RH12MCT)\u003c\/h3\u003e\n\u003cdiv class=\"hvx-table-wrap\"\u003e\n\u003ctable class=\"hvx-table\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eSpec\u003c\/th\u003e\n\u003cth\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRefrigerant Type\u003c\/td\u003e\n\u003ctd\u003eR454B\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSystem Type\u003c\/td\u003e\n\u003ctd\u003eSingle Zone\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBTU Rated\u003c\/td\u003e\n\u003ctd\u003e12,000\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower\u003c\/td\u003e\n\u003ctd\u003e208–230V • 1Ph • 60Hz (Voltage Range: 187–253V)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSEER2 \/ EER2\u003c\/td\u003e\n\u003ctd\u003e22.2 \/ 12.5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDehumidification\u003c\/td\u003e\n\u003ctd\u003e3.07 pints\/day\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIndoor Airflow (CFM)\u003c\/td\u003e\n\u003ctd\u003e417.9 \/ 364.9 \/ 306.1 \/ 194.2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNoise (dB(A))\u003c\/td\u003e\n\u003ctd\u003e43.5 \/ 40.5 \/ 27.5 (H\/M\/L)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUnit Dimensions (W×D×H)\u003c\/td\u003e\n\u003ctd\u003e22.44 × 22.44 × 9.65 in\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNet \/ Gross Weight\u003c\/td\u003e\n\u003ctd\u003e35.27 \/ 41.89 lb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRefrigerant Piping\u003c\/td\u003e\n\u003ctd\u003e1\/4\" Liquid • 3\/8\" Gas\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDrain Pipe Diameter\u003c\/td\u003e\n\u003ctd\u003e1\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Range\u003c\/td\u003e\n\u003ctd\u003eCooling: 60–90°F • Heating: 32–86°F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"hvx-desc-card\"\u003e\n\u003ch3 class=\"hvx-section-title\"\u003eOutdoor Specs (CH-RHP12-230VO)\u003c\/h3\u003e\n\u003cdiv class=\"hvx-table-wrap\"\u003e\n\u003ctable class=\"hvx-table\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eSpec\u003c\/th\u003e\n\u003cth\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRefrigerant Type\u003c\/td\u003e\n\u003ctd\u003eR454B\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated Capacity\u003c\/td\u003e\n\u003ctd\u003e12,000 BTU\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCooling Capacity (Min–Max)\u003c\/td\u003e\n\u003ctd\u003e12,000 (3,800–14,600) BTU\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHeating Capacity (Min–Max)\u003c\/td\u003e\n\u003ctd\u003e12,000 (3,800–16,000) BTU\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower\u003c\/td\u003e\n\u003ctd\u003e208–230V • 1Ph • 60Hz (Voltage Range: 187–253V)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHSPF2 (Region IV \/ V)\u003c\/td\u003e\n\u003ctd\u003e10.5 \/ 8.0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCOP\u003c\/td\u003e\n\u003ctd\u003e3.76\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax Pipe Length\u003c\/td\u003e\n\u003ctd\u003e82 ft\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax Height Difference\u003c\/td\u003e\n\u003ctd\u003e49.2 ft\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMinimum Circuit Ampacity\u003c\/td\u003e\n\u003ctd\u003e15 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax Fuse\u003c\/td\u003e\n\u003ctd\u003e15 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutdoor Airflow\u003c\/td\u003e\n\u003ctd\u003e1,470.6 CFM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutdoor Noise\u003c\/td\u003e\n\u003ctd\u003e56 dB(A)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUnit Dimensions (W×D×H)\u003c\/td\u003e\n\u003ctd\u003e31.69 × 12.99 × 21.81 in\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNet \/ Gross Weight\u003c\/td\u003e\n\u003ctd\u003e72.75 \/ 78.70 lb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAmbient Temperature\u003c\/td\u003e\n\u003ctd\u003eCooling: -22–122°F • Heating: -22–75°F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAdditional Charge\u003c\/td\u003e\n\u003ctd\u003e0.16 oz\/ft (1\/4\" liquid line)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"hvx-desc-card\"\u003e\n\u003ch3 class=\"hvx-section-title\"\u003eDocuments \u0026amp; Downloads\u003c\/h3\u003e\n\u003cul class=\"hvx-muted\" style=\"margin: 0; padding-left: 18px;\"\u003e\n\u003cli\u003e\u003ca class=\"hvx-link\" href=\"https:\/\/media.cooperandhunter.us\/4684\/CH-RHP12-230VO_CH-RH12MCT.pdf\"\u003eSubmittal Sheet: CH-RHP12-230VO + CH-RH12MCT\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca class=\"hvx-link\" href=\"https:\/\/media.cooperandhunter.us\/4118\/Installation-Manual-R454B-Outdoor-units--.pdf\"\u003eOutdoor Units Installation Manual (R454B)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca class=\"hvx-link\" href=\"https:\/\/media.cooperandhunter.us\/4200\/SlimDuct-Leaflet-R454B.pdf\"\u003eSlimDuct Leaflet (R454B)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca class=\"hvx-link\" href=\"https:\/\/media.cooperandhunter.us\/4654\/Installation-manual-R454B-Ceiling-cassette_compressed.pdf\"\u003eCeiling Cassette Installation Manual (R454B)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca class=\"hvx-link\" href=\"https:\/\/media.cooperandhunter.us\/4655\/Owners_-manual-R454B-Ceiling-cassette_compressed.pdf\"\u003eCeiling Cassette Owner’s Manual (R454B)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca class=\"hvx-link\" href=\"https:\/\/media.cooperandhunter.us\/4028\/120N-wire-controller---owners-manual.pdf\"\u003e120N Wire Controller Owner’s Manual\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca class=\"hvx-link\" href=\"https:\/\/media.cooperandhunter.us\/3198\/MultiZone-Combination-HYPER.pdf\"\u003eMultiZone Combination Guide — Hyper\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca class=\"hvx-link\" href=\"https:\/\/media.cooperandhunter.us\/3199\/MultiZone-Combination-Regular.pdf\"\u003eMultiZone Combination Guide — Regular\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca class=\"hvx-link\" href=\"https:\/\/media.cooperandhunter.us\/4170\/CH-RHP12-230VO-%2B-CH-RH12MASTWM-230VI.pdf\"\u003eSubmittal Sheet: CH-RHP12-230VO + CH-RH12MASTWM-230VI\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca class=\"hvx-link\" href=\"https:\/\/media.cooperandhunter.us\/4203\/CH-RHP12-230VO-%2B-CH-RS06-12MDT--MS.pdf\"\u003eSubmittal Sheet: CH-RHP12-230VO + CH-RS06-12MDT\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"hvx-desc-card\"\u003e\n\u003ch3 class=\"hvx-section-title\"\u003eImportant\u003c\/h3\u003e\n\u003cul class=\"hvx-muted\" style=\"margin: 0; padding-left: 18px;\"\u003e\n\u003cli\u003eProfessional installation is recommended.\u003c\/li\u003e\n\u003cli\u003eVerify electrical requirements: 208–230V dedicated circuit sized per nameplate\/MCA.\u003c\/li\u003e\n\u003cli\u003eUse correct line set sizing: 1\/4\" liquid and 3\/8\" suction.\u003c\/li\u003e\n\u003cli\u003eFor help choosing equipment, contact us: \u003ca class=\"hvx-link\" href=\"https:\/\/hvacsupplies.com\/pages\/contact\"\u003ehvacsupplies.com\/pages\/contact\u003c\/a\u003e • \u003ca class=\"hvx-link\" href=\"tel:+18005438933\"\u003e(800) 543-8933\u003c\/a\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"hvx-desc-card hvx-faq\"\u003e\n\u003ch3 class=\"hvx-section-title\"\u003eFAQs\u003c\/h3\u003e\n\u003cdetails\u003e\n\u003csummary\u003eDoes this cassette include a condensate pump?\u003c\/summary\u003e\n\u003cp class=\"hvx-muted\"\u003eYes. The indoor cassette includes a built-in pump with float switch (20.9\" lift).\u003c\/p\u003e\n\u003c\/details\u003e\n\u003cdetails\u003e\n\u003csummary\u003eWhat line set sizes are required?\u003c\/summary\u003e\n\u003cp class=\"hvx-muted\"\u003eThis cassette uses 1\/4\" liquid and 3\/8\" gas piping.\u003c\/p\u003e\n\u003c\/details\u003e\n\u003cdetails\u003e\n\u003csummary\u003eHow does the Hyper outdoor unit handle cold weather?\u003c\/summary\u003e\n\u003cp class=\"hvx-muted\"\u003eThe CH-RHP12-230VO supports heating operation down to -22°F ambient.\u003c\/p\u003e\n\u003c\/details\u003e\n\u003cdetails\u003e\n\u003csummary\u003eCan I control it with an app?\u003c\/summary\u003e\n\u003cp class=\"hvx-muted\"\u003eSmart Kit capability supports app control through the C\u0026amp;H platform after setup.\u003c\/p\u003e\n\u003c\/details\u003e\n\u003cdetails\u003e\n\u003csummary\u003eIs a wall thermostat required?\u003c\/summary\u003e\n\u003cp class=\"hvx-muted\"\u003eNo. The system supports remote control operation; wall thermostat options may be added if desired.\u003c\/p\u003e\n\u003c\/details\u003e\n\u003cdetails\u003e\n\u003csummary\u003eIs this single-zone only?\u003c\/summary\u003e\n\u003cp class=\"hvx-muted\"\u003eThis configuration is presented as single-zone pairing.\u003c\/p\u003e\n\u003c\/details\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e","brand":"Cooper\u0026Hunter","offers":[{"title":"No Installation","offer_id":42690672492587,"sku":"CH-RH12MCT + CH-RHP12-230VO","price":2026.42,"currency_code":"USD","in_stock":true},{"title":"16FT","offer_id":42690672525355,"sku":"CH-RH12MCT + CH-RHP12-230VO","price":2207.86,"currency_code":"USD","in_stock":true},{"title":"25FT","offer_id":42690672558123,"sku":"CH-RH12MCT + CH-RHP12-230VO","price":2253.94,"currency_code":"USD","in_stock":true},{"title":"50FT","offer_id":42690672590891,"sku":"CH-RH12MCT + CH-RHP12-230VO","price":2497.3,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0625\/5647\/1339\/files\/2-ZoneDuctlessMiniSplitAC_HeatPump48000BTU_26.png?v=1769199192"},{"product_id":"cooper-hunter-12-000-btu-single-zone-four-way-ceiling-cassette-w-humidity-sensor-minisplit-heat-pump-system-r454b-230v","title":"Cooper\u0026Hunter 12,000 BTU Single Zone Four-Way Ceiling Cassette w\/ Humidity Sensor Minisplit Heat Pump System R454B 230V","description":"\u003cstyle\u003e\n    :root{--hvx-golden:#FAA819; --hvx-slate:#262626; --hvx-ivory:#F4F1E6; --hvx-border:#e2e0d5; --hvx-card-bg:#ffffff;}\n    .hvx-desc{background:var(--hvx-ivory); padding:18px; border-radius:18px; font-family:\"Articulat CF\",system-ui,-apple-system,Segoe UI,Roboto,Arial,sans-serif; color:#111;}\n    .hvx-desc-header{background:linear-gradient(120deg,var(--hvx-golden),var(--hvx-slate)); border-radius:16px; padding:16px 16px 14px; color:#fff; margin-bottom:14px;}\n    .hvx-eyebrow{font-size:12px; letter-spacing:.12em; text-transform:uppercase; opacity:.9; margin:0 0 6px;}\n    .hvx-title{font-family:\"Anton\",Impact,Haettenschweiler,\"Arial Narrow Bold\",sans-serif; font-size:26px; line-height:1.05; margin:0;}\n    .hvx-desc-card{background:var(--hvx-card-bg); border:1px solid var(--hvx-border); border-radius:16px; padding:14px; margin:12px 0; box-shadow:0 10px 18px rgba(0,0,0,.06);}\n    .hvx-section-title{margin:0 0 10px; font-size:13px; letter-spacing:.12em; text-transform:uppercase; display:inline-block; padding-bottom:6px; position:relative;}\n    .hvx-section-title:after{content:\"\"; position:absolute; left:0; bottom:0; height:3px; width:100%; border-radius:99px; background:linear-gradient(90deg,var(--hvx-golden),var(--hvx-slate));}\n    .hvx-badges{display:flex; flex-wrap:wrap; gap:8px; margin:6px 0 10px;}\n    .hvx-badge{display:inline-flex; align-items:center; gap:6px; padding:6px 10px; border-radius:999px; border:1px solid var(--hvx-border); background:#fff; font-size:12px; font-weight:600;}\n    .hvx-grid{display:grid; grid-template-columns:repeat(3,minmax(0,1fr)); gap:10px;}\n    .hvx-kv{border:1px solid var(--hvx-border); border-radius:14px; padding:10px; background:#fff;}\n    .hvx-k{font-size:12px; letter-spacing:.08em; text-transform:uppercase; color:#333; margin:0 0 6px;}\n    .hvx-v{font-size:14px; font-weight:700; margin:0;}\n    .hvx-table-wrap{overflow:auto; border-radius:14px; border:1px solid var(--hvx-border); background:#fff;}\n    table.hvx-table{width:100%; border-collapse:collapse; min-width:520px;}\n    .hvx-table th,.hvx-table td{padding:10px 12px; border-bottom:1px solid var(--hvx-border); vertical-align:top; font-size:14px;}\n    .hvx-table th{background:rgba(250,168,25,.12); text-align:left; font-size:12px; letter-spacing:.1em; text-transform:uppercase;}\n    .hvx-table tr:last-child td{border-bottom:none;}\n    .hvx-link{color:#111; text-decoration:none; border-bottom:2px solid rgba(250,168,25,.7);}\n    .hvx-link:hover{border-bottom-color:#111;}\n    .hvx-faq details{border:1px solid var(--hvx-border); border-radius:14px; background:#fff; padding:10px 12px; margin:10px 0;}\n    .hvx-faq summary{cursor:pointer; font-weight:800;}\n    .hvx-muted{color:#333; margin:6px 0 0;}\n    @media (max-width:720px){ .hvx-grid{grid-template-columns:1fr;} .hvx-title{font-size:24px;} }\n  \u003c\/style\u003e\n\u003cdiv class=\"hvx-desc\"\u003e\n\u003cdiv class=\"hvx-desc-header\"\u003e\n\u003cp class=\"hvx-eyebrow\"\u003eSingle Zone • 4-Way Ceiling Cassette • R454B • 208–230V\u003c\/p\u003e\n\u003ch2 class=\"hvx-title\"\u003eCooper\u0026amp;Hunter 12,000 BTU Single Zone Four-Way Ceiling Cassette w\/ Humidity Sensor Minisplit Heat Pump System R454B 230V\u003c\/h2\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"hvx-desc-card\"\u003e\n\u003ch3 class=\"hvx-section-title\"\u003eOverview\u003c\/h3\u003e\n\u003cp class=\"hvx-muted\"\u003eA balanced 12K-class ceiling cassette pairing designed for even airflow, clean-air support, and efficient inverter operation. The CH-RH12MCT cassette delivers omni-directional comfort through a 360° air flow panel, while the CH-RES12-230VO outdoor unit provides dependable heating and cooling with strong efficiency.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"hvx-desc-card\"\u003e\n\u003ch3 class=\"hvx-section-title\"\u003eHighlights\u003c\/h3\u003e\n\u003cdiv class=\"hvx-badges\"\u003e\n\u003cspan class=\"hvx-badge\"\u003eR454B Refrigerant\u003c\/span\u003e \u003cspan class=\"hvx-badge\"\u003e360° Airflow Panel\u003c\/span\u003e \u003cspan class=\"hvx-badge\"\u003eHumidity Sensor\u003c\/span\u003e \u003cspan class=\"hvx-badge\"\u003eGoldFin Coil Coating\u003c\/span\u003e \u003cspan class=\"hvx-badge\"\u003eBuilt-In Condensate Pump\u003c\/span\u003e \u003cspan class=\"hvx-badge\"\u003eInverter Outdoor\u003c\/span\u003e\n\u003c\/div\u003e\n\u003cul style=\"margin: 0 0 10px; padding-left: 18px;\" class=\"hvx-muted\"\u003e\n\u003cli\u003eOmni-directional airflow with 360° panel for even room coverage.\u003c\/li\u003e\n\u003cli\u003eActivated carbon filtration support for fresher indoor air.\u003c\/li\u003e\n\u003cli\u003eAnti-cold-air heating behavior to reduce drafts.\u003c\/li\u003e\n\u003cli\u003eQuiet built-in pump with float switch (20.9\" lift) for condensate removal.\u003c\/li\u003e\n\u003cli\u003eTurbo operation, sleep mode, and multiple fan speeds.\u003c\/li\u003e\n\u003cli\u003eRegular outdoor unit supports low-ambient heating down to -13°F.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cdiv class=\"hvx-grid\"\u003e\n\u003cdiv class=\"hvx-kv\"\u003e\n\u003cp class=\"hvx-k\"\u003eIndoor Model\u003c\/p\u003e\n\u003cp class=\"hvx-v\"\u003e\u003ca href=\"https:\/\/hvacsupplies.com\/search?options%5Bprefix%5D=last\u0026amp;q=CH-RH12MCT\" class=\"hvx-link\"\u003eCH-RH12MCT\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"hvx-kv\"\u003e\n\u003cp class=\"hvx-k\"\u003eOutdoor Model\u003c\/p\u003e\n\u003cp class=\"hvx-v\"\u003e\u003ca href=\"https:\/\/hvacsupplies.com\/search?options%5Bprefix%5D=last\u0026amp;q=CH-RES12-230VO\" class=\"hvx-link\"\u003eCH-RES12-230VO\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"hvx-kv\"\u003e\n\u003cp class=\"hvx-k\"\u003eLine Set Size\u003c\/p\u003e\n\u003cp class=\"hvx-v\"\u003e1\/4\" Liquid • 3\/8\" Gas\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"hvx-kv\"\u003e\n\u003cp class=\"hvx-k\"\u003eSEER2\u003c\/p\u003e\n\u003cp class=\"hvx-v\"\u003e21.1\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"hvx-kv\"\u003e\n\u003cp class=\"hvx-k\"\u003eOutdoor Max Line Length\u003c\/p\u003e\n\u003cp class=\"hvx-v\"\u003e82 ft\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"hvx-kv\"\u003e\n\u003cp class=\"hvx-k\"\u003eLow-Ambient Heating\u003c\/p\u003e\n\u003cp class=\"hvx-v\"\u003eDown to -13°F\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"hvx-desc-card\"\u003e\n\u003ch3 class=\"hvx-section-title\"\u003eWhat’s Included\u003c\/h3\u003e\n\u003cul style=\"margin: 0; padding-left: 18px;\" class=\"hvx-muted\"\u003e\n\u003cli\u003eIndoor 4-way ceiling cassette: CH-RH12MCT\u003c\/li\u003e\n\u003cli\u003eOutdoor condenser: CH-RES12-230VO (Regular)\u003c\/li\u003e\n\u003cli\u003eRemote control (indoor control package)\u003c\/li\u003e\n\u003cli\u003eCeiling Cassette Panel\u003c\/li\u003e\n\u003cli\u003eBuilt-in condensate pump with float switch (indoor)\u003c\/li\u003e\n\u003cli\u003eSmart Kit capability for app control (setup required)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"hvx-desc-card\"\u003e\n\u003ch3 class=\"hvx-section-title\"\u003eIndoor Specs (CH-RH12MCT)\u003c\/h3\u003e\n\u003cdiv class=\"hvx-table-wrap\"\u003e\n\u003ctable class=\"hvx-table\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eSpec\u003c\/th\u003e\n\u003cth\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRefrigerant Type\u003c\/td\u003e\n\u003ctd\u003eR454B\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSystem Type\u003c\/td\u003e\n\u003ctd\u003eSingle Zone\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBTU Rated\u003c\/td\u003e\n\u003ctd\u003e12,000\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower\u003c\/td\u003e\n\u003ctd\u003e208–230V • 1Ph • 60Hz (Voltage Range: 187–253V)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSEER2 \/ EER2\u003c\/td\u003e\n\u003ctd\u003e22.2 \/ 12.5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDehumidification\u003c\/td\u003e\n\u003ctd\u003e3.07 pints\/day\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIndoor Airflow (CFM)\u003c\/td\u003e\n\u003ctd\u003e417.9 \/ 364.9 \/ 306.1 \/ 194.2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNoise (dB(A))\u003c\/td\u003e\n\u003ctd\u003e43.5 \/ 40.5 \/ 27.5 (H\/M\/L)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUnit Dimensions (W×D×H)\u003c\/td\u003e\n\u003ctd\u003e22.44 × 22.44 × 9.65 in\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNet \/ Gross Weight\u003c\/td\u003e\n\u003ctd\u003e35.27 \/ 41.89 lb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRefrigerant Piping\u003c\/td\u003e\n\u003ctd\u003e1\/4\" Liquid • 3\/8\" Gas\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDrain Pipe Diameter\u003c\/td\u003e\n\u003ctd\u003e1\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Range\u003c\/td\u003e\n\u003ctd\u003eCooling: 60–90°F • Heating: 32–86°F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"hvx-desc-card\"\u003e\n\u003ch3 class=\"hvx-section-title\"\u003eOutdoor Specs (CH-RES12-230VO)\u003c\/h3\u003e\n\u003cdiv class=\"hvx-table-wrap\"\u003e\n\u003ctable class=\"hvx-table\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eSpec\u003c\/th\u003e\n\u003cth\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRefrigerant Type\u003c\/td\u003e\n\u003ctd\u003eR454B\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated Capacity\u003c\/td\u003e\n\u003ctd\u003e12,000 BTU\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCooling Capacity (Min–Max)\u003c\/td\u003e\n\u003ctd\u003e11,500 (3,100–13,000) BTU\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHeating Capacity (Min–Max)\u003c\/td\u003e\n\u003ctd\u003e12,000 (3,700–15,600) BTU\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower\u003c\/td\u003e\n\u003ctd\u003e208–230V • 1Ph • 60Hz (Voltage Range: 187–253V)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSEER2 \/ EER2\u003c\/td\u003e\n\u003ctd\u003e19 \/ 11.7\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHSPF2 (Region IV \/ V)\u003c\/td\u003e\n\u003ctd\u003e10.2 \/ 8.0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCOP\u003c\/td\u003e\n\u003ctd\u003e3.42\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax Pipe Length\u003c\/td\u003e\n\u003ctd\u003e82 ft\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax Height Difference\u003c\/td\u003e\n\u003ctd\u003e49.2 ft\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMinimum Circuit Ampacity\u003c\/td\u003e\n\u003ctd\u003e12 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax Fuse\u003c\/td\u003e\n\u003ctd\u003e15 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutdoor Airflow\u003c\/td\u003e\n\u003ctd\u003e1,236.1 CFM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutdoor Noise\u003c\/td\u003e\n\u003ctd\u003e55.5 dB(A)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUnit Dimensions (W×D×H)\u003c\/td\u003e\n\u003ctd\u003e30.12 × 11.93 × 21.85 in\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNet \/ Gross Weight\u003c\/td\u003e\n\u003ctd\u003e62.17 \/ 67.68 lb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAmbient Temperature\u003c\/td\u003e\n\u003ctd\u003eCooling: -13–122°F • Heating: -13–75°F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAdditional Charge\u003c\/td\u003e\n\u003ctd\u003e0.16 oz\/ft (1\/4\" liquid line)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"hvx-desc-card\"\u003e\n\u003ch3 class=\"hvx-section-title\"\u003eDocuments \u0026amp; Downloads\u003c\/h3\u003e\n\u003cul style=\"margin: 0; padding-left: 18px;\" class=\"hvx-muted\"\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/media.cooperandhunter.us\/4676\/CH-RES12-230VO_CH-RH12MCT.pdf\" class=\"hvx-link\"\u003eSubmittal Sheet: CH-RES12-230VO + CH-RH12MCT\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/media.cooperandhunter.us\/4118\/Installation-Manual-R454B-Outdoor-units--.pdf\" class=\"hvx-link\"\u003eOutdoor Units Installation Manual (R454B)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/media.cooperandhunter.us\/4200\/SlimDuct-Leaflet-R454B.pdf\" class=\"hvx-link\"\u003eSlimDuct Leaflet (R454B)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/media.cooperandhunter.us\/4654\/Installation-manual-R454B-Ceiling-cassette_compressed.pdf\" class=\"hvx-link\"\u003eCeiling Cassette Installation Manual (R454B)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/media.cooperandhunter.us\/4655\/Owners_-manual-R454B-Ceiling-cassette_compressed.pdf\" class=\"hvx-link\"\u003eCeiling Cassette Owner’s Manual (R454B)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/media.cooperandhunter.us\/4028\/120N-wire-controller---owners-manual.pdf\" class=\"hvx-link\"\u003e120N Wire Controller Owner’s Manual\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/media.cooperandhunter.us\/3198\/MultiZone-Combination-HYPER.pdf\" class=\"hvx-link\"\u003eMultiZone Combination Guide — Hyper\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/media.cooperandhunter.us\/3199\/MultiZone-Combination-Regular.pdf\" class=\"hvx-link\"\u003eMultiZone Combination Guide — Regular\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/media.cooperandhunter.us\/4156\/CH-RES12-230VO-%2B-CH-PRO12MASTWM-230VI.pdf\" class=\"hvx-link\"\u003eSubmittal Sheet: CH-RES12-230VO + CH-PRO12MASTWM-230VI\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/media.cooperandhunter.us\/4169\/CH-RES12-230VO-%2B-CH-RH12MASTWM-230VI.pdf\" class=\"hvx-link\"\u003eSubmittal Sheet: CH-RES12-230VO + CH-RH12MASTWM-230VI\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/media.cooperandhunter.us\/4210\/CH-RES12-230VO-%2B-CH-RS06-12MDT--MS.pdf\" class=\"hvx-link\"\u003eSubmittal Sheet: CH-RES12-230VO + CH-RS06-12MDT\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/media.cooperandhunter.us\/4677\/CH-RES12-230VO_CH-RSH12MCT.pdf\" class=\"hvx-link\"\u003eSubmittal Sheet: CH-RES12-230VO + CH-RSH12MCT\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"hvx-desc-card\"\u003e\n\u003ch3 class=\"hvx-section-title\"\u003eImportant\u003c\/h3\u003e\n\u003cul style=\"margin: 0; padding-left: 18px;\" class=\"hvx-muted\"\u003e\n\u003cli\u003eProfessional installation is recommended.\u003c\/li\u003e\n\u003cli\u003eVerify electrical requirements: 208–230V dedicated circuit sized per nameplate\/MCA.\u003c\/li\u003e\n\u003cli\u003eUse correct line set sizing: 1\/4\" liquid and 3\/8\" suction.\u003c\/li\u003e\n\u003cli\u003eFor help choosing equipment, contact us: \u003ca href=\"https:\/\/hvacsupplies.com\/pages\/contact\" class=\"hvx-link\"\u003ehvacsupplies.com\/pages\/contact\u003c\/a\u003e • \u003ca href=\"tel:+18005438933\" class=\"hvx-link\"\u003e(800) 543-8933\u003c\/a\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"hvx-desc-card hvx-faq\"\u003e\n\u003ch3 class=\"hvx-section-title\"\u003eFAQs\u003c\/h3\u003e\n\u003cdetails\u003e\n\u003csummary\u003eDoes this cassette include a condensate pump?\u003c\/summary\u003e\n\u003cp class=\"hvx-muted\"\u003eYes. The indoor cassette includes a built-in pump with float switch (20.9\" lift).\u003c\/p\u003e\n\u003c\/details\u003e\n\u003cdetails\u003e\n\u003csummary\u003eWhat line set sizes are required?\u003c\/summary\u003e\n\u003cp class=\"hvx-muted\"\u003eThis cassette uses 1\/4\" liquid and 3\/8\" gas piping.\u003c\/p\u003e\n\u003c\/details\u003e\n\u003cdetails\u003e\n\u003csummary\u003eHow cold can the regular outdoor unit operate in heating?\u003c\/summary\u003e\n\u003cp class=\"hvx-muted\"\u003eThe CH-RES12-230VO supports heating operation down to -13°F ambient.\u003c\/p\u003e\n\u003c\/details\u003e\n\u003cdetails\u003e\n\u003csummary\u003eCan I control it with an app?\u003c\/summary\u003e\n\u003cp class=\"hvx-muted\"\u003eSmart Kit capability supports app control through the C\u0026amp;H platform after setup.\u003c\/p\u003e\n\u003c\/details\u003e\n\u003cdetails\u003e\n\u003csummary\u003eIs a wall thermostat required?\u003c\/summary\u003e\n\u003cp class=\"hvx-muted\"\u003eNo. The system supports remote control operation; wall thermostat options may be added if desired.\u003c\/p\u003e\n\u003c\/details\u003e\n\u003cdetails\u003e\n\u003csummary\u003eIs this single-zone only?\u003c\/summary\u003e\n\u003cp class=\"hvx-muted\"\u003eThis configuration is presented as single-zone pairing.\u003c\/p\u003e\n\u003c\/details\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e","brand":"Cooper\u0026Hunter","offers":[{"title":"No Installation","offer_id":42690705358891,"sku":"CH-RH12MCT + CH-RES12-230VO","price":1794.24,"currency_code":"USD","in_stock":true},{"title":"16FT","offer_id":42690705391659,"sku":"CH-RH12MCT + CH-RES12-230VO","price":1975.68,"currency_code":"USD","in_stock":true},{"title":"25FT","offer_id":42690705424427,"sku":"CH-RH12MCT + CH-RES12-230VO","price":2021.76,"currency_code":"USD","in_stock":true},{"title":"50FT","offer_id":42690705457195,"sku":"CH-RH12MCT + CH-RES12-230VO","price":2265.12,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0625\/5647\/1339\/files\/FourWay_Regular_Product_Hero_48_33b3a9f5-7a1c-442f-a881-e51e604eb6c3.png?v=1769199174"},{"product_id":"mrcool-4th-gen-olympus-e-star-12-000-btu-single-zone-mini-split-with-ceiling-air-handler-and-heat-pump-condenser","title":"MRCOOL 4th Gen Olympus E Star 12,000 BTU Single Zone Mini Split with Ceiling Air Handler and Heat Pump Condenser","description":"\u003cstyle\u003e\n  :root{\n    --hvx-golden:#FAA819;\n    --hvx-slate:#262626;\n    --hvx-ivory:#F4F1E6;\n    --hvx-border:#e2e0d5;\n    --hvx-card-bg:#ffffff;\n    --hvx-muted:#5c5a52;\n  }\n\n  .hvx-desc{\n    font-family:\"Articulat CF\",system-ui,-apple-system,BlinkMacSystemFont,\"Segoe UI\",sans-serif;\n    color:var(--hvx-slate);\n    line-height:1.6;\n    background:var(--hvx-ivory);\n    padding:18px 18px 20px;\n    border-radius:16px;\n  }\n\n  .hvx-desc-header{\n    border-radius:14px;\n    padding:14px 16px;\n    background:linear-gradient(120deg,var(--hvx-golden),var(--hvx-slate));\n    color:#fff;\n    margin:0 0 16px;\n    box-shadow:0 10px 24px rgba(0,0,0,.22);\n    display:flex;\n    align-items:center;\n    gap:12px;\n    flex-wrap:wrap;\n  }\n\n  .hvx-header-text{display:flex;flex-direction:column;gap:4px;min-width:240px}\n  .hvx-eyebrow{\n    font-size:11px;\n    letter-spacing:.14em;\n    text-transform:uppercase;\n    opacity:.9;\n  }\n  .hvx-title{\n    margin:0;\n    font-family:\"Anton\",\"Impact\",system-ui,-apple-system,BlinkMacSystemFont,\"Segoe UI\",sans-serif;\n    font-size:22px;\n    line-height:1.15;\n  }\n  .hvx-sub{margin:10px 0 0;font-size:14px;color:#3b3b3b}\n\n  .hvx-desc-card{\n    border:1px solid var(--hvx-border);\n    border-radius:14px;\n    background:var(--hvx-card-bg);\n    padding:16px 18px 18px;\n    box-shadow:0 4px 12px rgba(0,0,0,.06);\n    margin:14px 0;\n  }\n\n  .hvx-section-title{\n    margin:0 0 8px;\n    font-family:\"Anton\",\"Impact\",system-ui,-apple-system,BlinkMacSystemFont,\"Segoe UI\",sans-serif;\n    font-size:17px;\n    letter-spacing:.08em;\n    text-transform:uppercase;\n    color:var(--hvx-slate);\n    display:inline-flex;\n    align-items:center;\n    gap:8px;\n  }\n  .hvx-section-title::after{\n    content:\"\";\n    flex:1;\n    height:2px;\n    border-radius:999px;\n    background:linear-gradient(90deg,var(--hvx-golden),transparent);\n    opacity:.9;\n  }\n\n  .hvx-badges{display:flex;flex-wrap:wrap;gap:8px;margin:10px 0 2px}\n  .hvx-badge{\n    font-size:12px;\n    border:1px solid var(--hvx-border);\n    border-radius:999px;\n    padding:6px 10px;\n    background:#fff;\n    color:var(--hvx-slate);\n    white-space:nowrap;\n  }\n\n  .hvx-cta{display:flex;flex-wrap:wrap;gap:10px;margin:10px 0 0}\n  .hvx-cta a{\n    display:inline-flex;\n    align-items:center;\n    gap:8px;\n    padding:10px 14px;\n    border-radius:12px;\n    border:1px solid var(--hvx-border);\n    background:#fff;\n    text-decoration:none;\n    color:var(--hvx-slate);\n    font-size:14px;\n    font-weight:600;\n  }\n  .hvx-cta a.primary{\n    background:var(--hvx-slate);\n    color:#fff;\n    border-color:transparent;\n  }\n\n  .hvx-list{margin:6px 0 10px;padding-left:18px;font-size:14px}\n  .hvx-note{margin:8px 0 0;font-size:12px;color:var(--hvx-muted)}\n\n  .hvx-kv{display:grid;grid-template-columns:1fr 1fr;gap:8px;margin-top:8px}\n  .hvx-kv\u003ediv{\n    padding:10px 10px;\n    border:1px solid var(--hvx-border);\n    border-radius:12px;\n    background:#fff;\n    text-align:center;\n    font-size:14px;\n  }\n\n  .hvx-table-wrap{width:100%;overflow-x:auto}\n  .hvx-table{width:100%;border-collapse:collapse;font-size:13px;min-width:520px}\n  .hvx-th,.hvx-td{border:1px solid var(--hvx-border);padding:9px 11px;text-align:left;vertical-align:top;line-height:1.45}\n  .hvx-th{background:#f7f3e8;color:var(--hvx-slate);width:28ch;font-weight:700}\n\n  details{border:1px solid var(--hvx-border);border-radius:12px;padding:12px 14px;background:#fff}\n  summary{cursor:pointer;font-weight:800}\n\n  @media(max-width:768px){\n    .hvx-desc{padding:14px 12px 16px;border-radius:12px}\n    .hvx-desc-header{padding:12px;border-radius:12px}\n    .hvx-title{font-size:19px}\n    .hvx-desc-card{padding:14px;margin:10px 0}\n  }\n\u003c\/style\u003e\n\u003cdiv class=\"hvx-desc\"\u003e\n\u003cdiv class=\"hvx-desc-header\"\u003e\n\u003cdiv class=\"hvx-header-text\"\u003e\n\u003cdiv class=\"hvx-eyebrow\"\u003eMRCOOL — Olympus 4th Gen (Ceiling Cassette Single-Zone)\u003c\/div\u003e\n\u003ch1 class=\"hvx-title\"\u003eMRCOOL® Olympus 12,000 BTU (1 Ton) Ceiling Cassette Mini Split Heat Pump — O-ES-12-HP-C-230C-O1 + CASSETTE12HP-230C-P-O\u003c\/h1\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv aria-label=\"Contact options\" class=\"hvx-cta\"\u003e\n\u003ca rel=\"noopener\" href=\"https:\/\/hvacsupplies.com\/pages\/contact\" class=\"primary\"\u003eContact for custom quotes\u003c\/a\u003e \u003ca aria-label=\"Call 800-543-8933\" href=\"tel:+18005438933\"\u003eCall 800-543-8933\u003c\/a\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"hvx-desc-card\"\u003e\n\u003ch2 class=\"hvx-section-title\"\u003eOverview\u003c\/h2\u003e\n\u003cdiv aria-label=\"Key badges\" class=\"hvx-badges\"\u003e\n\u003cspan class=\"hvx-badge\"\u003e12,000 BTU Cooling\u003c\/span\u003e \u003cspan class=\"hvx-badge\"\u003e12,000 BTU Heating\u003c\/span\u003e \u003cspan class=\"hvx-badge\"\u003eUp to 25.4 SEER2\u003c\/span\u003e \u003cspan class=\"hvx-badge\"\u003eUp to 13.4 EER2\u003c\/span\u003e \u003cspan class=\"hvx-badge\"\u003eHSPF2-4 10.5\u003c\/span\u003e \u003cspan class=\"hvx-badge\"\u003e1 Ton\u003c\/span\u003e \u003cspan class=\"hvx-badge\"\u003eR-454B\u003c\/span\u003e \u003cspan class=\"hvx-badge\"\u003eCeiling Cassette\u003c\/span\u003e \u003cspan class=\"hvx-badge\"\u003e5 Speeds (Variable)\u003c\/span\u003e \u003cspan class=\"hvx-badge\"\u003eDC Inverter\u003c\/span\u003e \u003cspan class=\"hvx-badge\"\u003eENERGY STAR®\u003c\/span\u003e \u003cspan class=\"hvx-badge\"\u003eAHRI Certified\u003c\/span\u003e \u003cspan class=\"hvx-badge\"\u003eRemote Included\u003c\/span\u003e \u003cspan class=\"hvx-badge\"\u003ePro Install Required\u003c\/span\u003e\n\u003c\/div\u003e\n\u003cp class=\"hvx-sub\"\u003eThe \u003cstrong\u003eMRCOOL® Olympus 12K Ceiling Cassette\u003c\/strong\u003e delivers reliable heating and cooling for smaller spaces while keeping a clean, flush ceiling appearance. It pairs a ceiling cassette (with panel) with an inverter-driven outdoor unit for efficient performance using \u003cstrong\u003eR-454B\u003c\/strong\u003e refrigerant.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"hvx-desc-card\"\u003e\n\u003ch2 class=\"hvx-section-title\"\u003eHighlights\u003c\/h2\u003e\n\u003cul class=\"hvx-list\"\u003e\n\u003cli\u003e\n\u003cstrong\u003eFlush ceiling look:\u003c\/strong\u003e Cassette design blends into the ceiling for a sleek, modern finish.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCoverage:\u003c\/strong\u003e Designed for areas up to \u003cstrong\u003e550 sq ft\u003c\/strong\u003e.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQuiet comfort:\u003c\/strong\u003e Indoor sound levels down to \u003cstrong\u003e26 dB(A)\u003c\/strong\u003e with a high rating of \u003cstrong\u003e46 dB(A)\u003c\/strong\u003e.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDownflow delivery:\u003c\/strong\u003e Downflow airflow with \u003cstrong\u003eoscillation\u003c\/strong\u003e for better room mixing.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEnergy efficiency:\u003c\/strong\u003e High efficiency ratings with inverter-driven outdoor performance.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEasy maintenance:\u003c\/strong\u003e \u003cstrong\u003eReusable filter\u003c\/strong\u003e design.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cdiv aria-label=\"Quick specs\" class=\"hvx-kv\"\u003e\n\u003cdiv\u003e\n\u003cstrong\u003eCoverage\u003c\/strong\u003e\u003cbr\u003eUp to 550 sq ft*\u003c\/div\u003e\n\u003cdiv\u003e\n\u003cstrong\u003eCooling \/ Heating\u003c\/strong\u003e\u003cbr\u003e12,000 \/ 12,000 BTU\u003c\/div\u003e\n\u003cdiv\u003e\n\u003cstrong\u003eEfficiency\u003c\/strong\u003e\u003cbr\u003eUp to 25.4 SEER2\u003c\/div\u003e\n\u003cdiv\u003e\n\u003cstrong\u003eSound\u003c\/strong\u003e\u003cbr\u003eIndoor 26–46 dB(A)\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cp class=\"hvx-note\"\u003e*Coverage varies by climate, insulation, layout, and load.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"hvx-desc-card\"\u003e\n\u003ch2 class=\"hvx-section-title\"\u003eWhat’s Included\u003c\/h2\u003e\n\u003cul class=\"hvx-list\"\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutdoor Condenser:\u003c\/strong\u003e O-ES-12-HP-C-230C-O1\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCeiling Cassette (with Panel):\u003c\/strong\u003e CASSETTE12HP-230C-P-O\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eRemote Control\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003eInstallation \/ user documentation (see Documents \u0026amp; Downloads)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"hvx-desc-card\"\u003e\n\u003ch2 class=\"hvx-section-title\"\u003eIndoor Specs\u003c\/h2\u003e\n\u003cp class=\"hvx-sub\"\u003e\u003cstrong\u003eModel:\u003c\/strong\u003e CASSETTE12HP-230C-P-O (Ceiling Cassette with Panel)\u003c\/p\u003e\n\u003cdiv class=\"hvx-table-wrap\"\u003e\n\u003ctable aria-label=\"Indoor cassette specs\" class=\"hvx-table\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd class=\"hvx-th\"\u003eSystem Type\u003c\/td\u003e\n\u003ctd class=\"hvx-td\"\u003eSingle-Zone Ductless Mini Split (Ceiling Cassette)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"hvx-th\"\u003eTonnage\u003c\/td\u003e\n\u003ctd class=\"hvx-td\"\u003e1 Ton\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"hvx-th\"\u003eMax Coverage Area\u003c\/td\u003e\n\u003ctd class=\"hvx-td\"\u003eUp to 550 sq ft\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"hvx-th\"\u003eAirflow Direction\u003c\/td\u003e\n\u003ctd class=\"hvx-td\"\u003eDownflow\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"hvx-th\"\u003eIndoor Noise (dB[A])\u003c\/td\u003e\n\u003ctd class=\"hvx-td\"\u003e46 \/ 43.5 \/ 40.5 \/ 27.5 \/ 26\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"hvx-th\"\u003eNumber of Speeds\u003c\/td\u003e\n\u003ctd class=\"hvx-td\"\u003e5 (Variable)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"hvx-th\"\u003eOscillation\u003c\/td\u003e\n\u003ctd class=\"hvx-td\"\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"hvx-th\"\u003eWiFi \/ App\u003c\/td\u003e\n\u003ctd class=\"hvx-td\"\u003eNo \/ No\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"hvx-th\"\u003eRemote Control Included\u003c\/td\u003e\n\u003ctd class=\"hvx-td\"\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"hvx-th\"\u003eElectrical\u003c\/td\u003e\n\u003ctd class=\"hvx-td\"\u003e208\/230V • 1-Phase • 60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"hvx-th\"\u003eMax Fuse \/ Breaker\u003c\/td\u003e\n\u003ctd class=\"hvx-td\"\u003e15A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"hvx-th\"\u003eMin Circuit Ampacity\u003c\/td\u003e\n\u003ctd class=\"hvx-td\"\u003e3A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"hvx-th\"\u003eLine Set Fitting Type\u003c\/td\u003e\n\u003ctd class=\"hvx-td\"\u003eFlare\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"hvx-th\"\u003eLiquid \/ Suction Line\u003c\/td\u003e\n\u003ctd class=\"hvx-td\"\u003e1\/4\" \/ 3\/8\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"hvx-th\"\u003eBlower Motor Speeds\u003c\/td\u003e\n\u003ctd class=\"hvx-td\"\u003e417.9 \/ 364.9 \/ 306.1 \/ 194.2 \/ 147.2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"hvx-th\"\u003eBlower Motor RPM\u003c\/td\u003e\n\u003ctd class=\"hvx-td\"\u003e700 \/ 600 \/ 400\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"hvx-th\"\u003eFilter Type\u003c\/td\u003e\n\u003ctd class=\"hvx-td\"\u003eReusable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"hvx-th\"\u003eFan Only \/ Sleep \/ Auto Cool\u003c\/td\u003e\n\u003ctd class=\"hvx-td\"\u003eYes \/ Yes \/ Yes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"hvx-th\"\u003eColor \/ Mount Type\u003c\/td\u003e\n\u003ctd class=\"hvx-td\"\u003eWhite \/ Ceiling\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"hvx-th\"\u003eDimensions (W×D×H)\u003c\/td\u003e\n\u003ctd class=\"hvx-td\"\u003e22.44\" × 24.44\" × 9.65\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"hvx-th\"\u003eNet Weight\u003c\/td\u003e\n\u003ctd class=\"hvx-td\"\u003e35.27 lb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"hvx-th\"\u003eUPC \/ GTIN\u003c\/td\u003e\n\u003ctd class=\"hvx-td\"\u003eUPC 840255587976 • GTIN 00840255587976\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"hvx-th\"\u003eRestricted States\u003c\/td\u003e\n\u003ctd class=\"hvx-td\"\u003eGU, PR, VI\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"hvx-th\"\u003eProposition 65 Warning\u003c\/td\u003e\n\u003ctd class=\"hvx-td\"\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"hvx-th\"\u003eWorks With\u003c\/td\u003e\n\u003ctd class=\"hvx-td\"\u003eO-ES-12-HP-C-230C-O1 • MULTI3-18HP230C-O • MULTI4-27HP230C-O • MULTI5-36HP230C-O • MULTI6-48HP230C-O\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"hvx-desc-card\"\u003e\n\u003ch2 class=\"hvx-section-title\"\u003eOutdoor Specs\u003c\/h2\u003e\n\u003cp class=\"hvx-sub\"\u003e\u003cstrong\u003eModel:\u003c\/strong\u003e O-ES-12-HP-C-230C-O1 (Single-Zone Condenser)\u003c\/p\u003e\n\u003cdiv class=\"hvx-table-wrap\"\u003e\n\u003ctable aria-label=\"Outdoor condenser specs\" class=\"hvx-table\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd class=\"hvx-th\"\u003eSystem Type\u003c\/td\u003e\n\u003ctd class=\"hvx-td\"\u003eSingle-Zone Ductless Mini Split Heat Pump\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"hvx-th\"\u003eTonnage\u003c\/td\u003e\n\u003ctd class=\"hvx-td\"\u003e1 Ton\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"hvx-th\"\u003eCooling \/ Heating Capacity\u003c\/td\u003e\n\u003ctd class=\"hvx-td\"\u003e12,000 BTU \/ 12,000 BTU\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"hvx-th\"\u003eMax Coverage Area\u003c\/td\u003e\n\u003ctd class=\"hvx-td\"\u003eUp to 550 sq ft\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"hvx-th\"\u003eSEER2 \/ EER2\u003c\/td\u003e\n\u003ctd class=\"hvx-td\"\u003eUp to 25.4 \/ Up to 13.4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"hvx-th\"\u003eHSPF2-4 \/ HSPF2-5\u003c\/td\u003e\n\u003ctd class=\"hvx-td\"\u003e10.5 \/ 8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"hvx-th\"\u003eOutdoor Noise\u003c\/td\u003e\n\u003ctd class=\"hvx-td\"\u003e56 dB(A)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"hvx-th\"\u003eElectrical\u003c\/td\u003e\n\u003ctd class=\"hvx-td\"\u003e208\/230V • 1-Phase • 60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"hvx-th\"\u003eMCA \/ Max Breaker\u003c\/td\u003e\n\u003ctd class=\"hvx-td\"\u003e15A \/ 15A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"hvx-th\"\u003eRefrigerant\u003c\/td\u003e\n\u003ctd class=\"hvx-td\"\u003eR-454B • 35.27 oz factory charge\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"hvx-th\"\u003eInverter\u003c\/td\u003e\n\u003ctd class=\"hvx-td\"\u003eDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"hvx-th\"\u003eCompressor Motor Type\u003c\/td\u003e\n\u003ctd class=\"hvx-td\"\u003eRotary\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"hvx-th\"\u003eMetering Device\u003c\/td\u003e\n\u003ctd class=\"hvx-td\"\u003eEXV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"hvx-th\"\u003eLine Set\u003c\/td\u003e\n\u003ctd class=\"hvx-td\"\u003eFlared fittings • Liquid 1\/4\" • Suction 3\/8\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"hvx-th\"\u003eMax Line Set Length\u003c\/td\u003e\n\u003ctd class=\"hvx-td\"\u003e82 ft\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"hvx-th\"\u003eDimensions (W×D×H)\u003c\/td\u003e\n\u003ctd class=\"hvx-td\"\u003e31.69\" × 12.99\" × 21.81\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"hvx-th\"\u003eNet Weight\u003c\/td\u003e\n\u003ctd class=\"hvx-td\"\u003e72.75 lb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"hvx-th\"\u003eEnergy Star Certified\u003c\/td\u003e\n\u003ctd class=\"hvx-td\"\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"hvx-th\"\u003eAHRI Certified\u003c\/td\u003e\n\u003ctd class=\"hvx-td\"\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"hvx-th\"\u003eUPC \/ GTIN\u003c\/td\u003e\n\u003ctd class=\"hvx-td\"\u003eUPC 840255587631 • GTIN 00840255587631\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"hvx-th\"\u003eRestricted States\u003c\/td\u003e\n\u003ctd class=\"hvx-td\"\u003eGU, PR, VI\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"hvx-th\"\u003eProposition 65 Warning\u003c\/td\u003e\n\u003ctd class=\"hvx-td\"\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"hvx-th\"\u003eWorks With\u003c\/td\u003e\n\u003ctd class=\"hvx-td\"\u003eO-12-HP-WMAH-230C-O • DUCT-12HP-230B-O • CASSETTE12HP-230C-O\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"hvx-desc-card\"\u003e\n\u003ch2 class=\"hvx-section-title\"\u003eDocuments \u0026amp; Downloads\u003c\/h2\u003e\n\u003cul class=\"hvx-list\"\u003e\n\u003cli\u003e\u003ca rel=\"noopener\" href=\"https:\/\/doxrepo.mrcool.com\/mc-oly-mz-4g-br-en.pdf\" target=\"_blank\"\u003eOlympus Multi-Zone 4th Gen Brochure (EN)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca rel=\"noopener\" href=\"https:\/\/doxrepo.mrcool.com\/mc-oly-mz-4g-cass-im-um-en-01.pdf\" target=\"_blank\"\u003eCeiling Cassette Installation \u0026amp; User Manual (EN)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca rel=\"noopener\" href=\"https:\/\/doxrepo.mrcool.com\/mc-oly-mz-4g-perf-ss-CASS-en.pdf\" target=\"_blank\"\u003eCeiling Cassette Performance \/ Spec Sheet (EN)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca rel=\"noopener\" href=\"https:\/\/doxrepo.mrcool.com\/mc-oly-mz-4g-cass-sm-en-01.pdf\" target=\"_blank\"\u003eCeiling Cassette Service Manual (EN)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\n\u003ca rel=\"noopener\" href=\"https:\/\/doxrepo.mrcool.com\/mc-oly-4g-sz-mz-wr-en-01.pdf\" target=\"_blank\"\u003eWarranty (EN)\u003c\/a\u003e\u003ca rel=\"noopener\" href=\"https:\/\/doxrepo.mrcool.com\/mc-oly-mz-4g-cass-im-um-fr-ca-01.pdf\" target=\"_blank\"\u003e\u003c\/a\u003e\n\u003c\/li\u003e\n\u003cli\u003e\u003ca rel=\"noopener\" href=\"https:\/\/doxrepo.mrcool.com\/mc-oly-sz-4g-br-en.pdf\" target=\"_blank\"\u003eOlympus Single-Zone 4th Gen Brochure (EN)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca rel=\"noopener\" href=\"https:\/\/doxrepo.mrcool.com\/mc-oly-sz-4g-im-um-en-01.pdf\" target=\"_blank\"\u003eSingle-Zone Installation \u0026amp; User Manual (EN)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca rel=\"noopener\" href=\"https:\/\/doxrepo.mrcool.com\/mc-oly-sz-4g-sm-en-01.pdf\" target=\"_blank\"\u003eSingle-Zone Service Manual (EN)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca rel=\"noopener\" href=\"https:\/\/doxrepo.mrcool.com\/AHRI\/mc-O-ES-12-HP-C-230C-O1-certs.pdf\" target=\"_blank\"\u003eAHRI Certificate (PDF)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca rel=\"noopener\" href=\"https:\/\/doxrepo.mrcool.com\/EnergyGuide\/mc-O-ES-12-HP-C-230C-O1-eg-certs.pdf\" target=\"_blank\"\u003eEnergyGuide (PDF)\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"hvx-desc-card\"\u003e\n\u003ch2 class=\"hvx-section-title\"\u003eImportant\u003c\/h2\u003e\n\u003cul class=\"hvx-list\"\u003e\n\u003cli\u003e\n\u003cstrong\u003eProfessional installation:\u003c\/strong\u003e Installation by a licensed HVAC professional required where applicable.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eElectrical circuit:\u003c\/strong\u003e Size the circuit from the outdoor unit: \u003cstrong\u003e15A MCA\u003c\/strong\u003e with a \u003cstrong\u003e15A max breaker\u003c\/strong\u003e.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRefrigerant \u0026amp; line length:\u003c\/strong\u003e Factory charge supports standard runs; longer runs may require additional refrigerant.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProposition 65:\u003c\/strong\u003e Warning applies (see product documentation).\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"hvx-desc-card\"\u003e\n\u003ch2 class=\"hvx-section-title\"\u003eFAQs\u003c\/h2\u003e\n\u003cdetails open=\"\"\u003e\n\u003csummary\u003eDoes this cassette include WiFi \/ app control?\u003c\/summary\u003e\n\u003cp class=\"hvx-sub\"\u003eNo. This cassette model is listed as \u003cstrong\u003eno WiFi\u003c\/strong\u003e and \u003cstrong\u003eno app compatibility\u003c\/strong\u003e. Remote control is included.\u003c\/p\u003e\n\u003c\/details\u003e\n\u003cdiv style=\"height: 10px;\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cdetails open=\"\"\u003e\n\u003csummary\u003eWhat line set sizes does it use?\u003c\/summary\u003e\n\u003cp class=\"hvx-sub\"\u003eFlare connections: \u003cstrong\u003e1\/4\" liquid\u003c\/strong\u003e and \u003cstrong\u003e3\/8\" suction\u003c\/strong\u003e.\u003c\/p\u003e\n\u003c\/details\u003e\n\u003cdiv style=\"height: 10px;\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cdetails open=\"\"\u003e\n\u003csummary\u003eWhat electrical circuit is required?\u003c\/summary\u003e\n\u003cp class=\"hvx-sub\"\u003e208\/230V, 1-phase, 60 Hz. The outdoor unit specifies \u003cstrong\u003e15A MCA\u003c\/strong\u003e and a \u003cstrong\u003e15A max breaker\u003c\/strong\u003e.\u003c\/p\u003e\n\u003c\/details\u003e\n\u003cdiv style=\"height: 10px;\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cdetails open=\"\"\u003e\n\u003csummary\u003eWhat warranty comes with it?\u003c\/summary\u003e\n\u003cp class=\"hvx-sub\"\u003eBase warranty includes \u003cstrong\u003e5-year parts\u003c\/strong\u003e and \u003cstrong\u003e7-year compressor coverage\u003c\/strong\u003e (see the warranty document for full terms).\u003c\/p\u003e\n\u003c\/details\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e","brand":"MRCOOL","offers":[{"title":"No Installation","offer_id":43028574044203,"sku":"O-ES-12-HP-C-230C-O1 + CASSETTE12HP-230C-P-O","price":1774.0,"currency_code":"USD","in_stock":true},{"title":"16FT","offer_id":43028574076971,"sku":"O-ES-12-HP-C-230C-O1 + CASSETTE12HP-230C-P-O + MC16-1438","price":1895.0,"currency_code":"USD","in_stock":true},{"title":"25FT","offer_id":43028574109739,"sku":"O-ES-12-HP-C-230C-O1 + CASSETTE12HP-230C-P-O + MC25-1438","price":1900.0,"currency_code":"USD","in_stock":true},{"title":"50FT","offer_id":43028574142507,"sku":"O-ES-12-HP-C-230C-O1 + CASSETTE12HP-230C-P-O + MC50-1438","price":2082.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0625\/5647\/1339\/files\/1-Zone9K-36K_800x_f6e85c87-8a8d-4924-b086-c3eb8f8318be.webp?v=1769538660"},{"product_id":"bravo-12-000-btu-pisa-series-up-to-22-0-seer2-single-zone-ceiling-cassette-mini-split-heat-pump-system-w-16ft-installation-kit-r32-230v","title":"Bravo 12,000 BTU Pisa Series Up to 22.0 SEER2 Single Zone Ceiling Cassette Mini Split Heat Pump System w\/ 16ft Installation Kit - R32 | 230V","description":"\u003cstyle\u003e\n  :root {\n    --hvx-golden: #FAA819;\n    --hvx-slate: #262626;\n    --hvx-ivory: #F4F1E6;\n    --hvx-border: #e2e0d5;\n    --hvx-card-bg: #ffffff;\n  }\n\n  .hvx-desc{\n    font-family:\"Articulat CF\",system-ui,-apple-system,BlinkMacSystemFont,\"Segoe UI\",sans-serif;\n    color:var(--hvx-slate);\n    line-height:1.6;\n    background:var(--hvx-ivory);\n    padding:18px 18px 20px;\n    border-radius:16px;\n  }\n\n  .hvx-desc-header{\n    border-radius:14px;\n    padding:14px 16px;\n    background:linear-gradient(120deg,var(--hvx-golden),var(--hvx-slate));\n    color:#fff;\n    margin:0 0 16px;\n    box-shadow:0 10px 24px rgba(0,0,0,.22);\n    display:flex;\n    align-items:flex-start;\n    gap:12px;\n    flex-wrap:wrap;\n  }\n\n  .hvx-header-text{display:flex;flex-direction:column;gap:6px;min-width:260px}\n  .hvx-eyebrow{font-size:11px;letter-spacing:.14em;text-transform:uppercase;opacity:.9;}\n  .hvx-title{margin:0;font-family:\"Anton\",\"Impact\",system-ui,-apple-system,BlinkMacSystemFont,\"Segoe UI\",sans-serif;font-size:22px;line-height:1.15;}\n  .hvx-subtitle{margin:0;font-size:14px;opacity:.95}\n\n  .hvx-desc-card{border:1px solid var(--hvx-border);border-radius:14px;background:var(--hvx-card-bg);padding:16px 18px 18px;box-shadow:0 4px 12px rgba(0,0,0,.06);margin:14px 0;}\n  .hvx-section-title{margin:0 0 10px;font-family:\"Anton\",\"Impact\",system-ui,-apple-system,BlinkMacSystemFont,\"Segoe UI\",sans-serif;font-size:17px;letter-spacing:.08em;text-transform:uppercase;color:var(--hvx-slate);display:inline-flex;align-items:center;gap:8px;}\n  .hvx-section-title::after{content:\"\";flex:1;height:2px;border-radius:999px;background:linear-gradient(90deg,var(--hvx-golden),transparent);opacity:.9;}\n  .hvx-cta{display:flex;flex-wrap:wrap;gap:10px;margin:10px 0 0}\n  .hvx-cta a{display:inline-flex;align-items:center;gap:8px;padding:10px 14px;border-radius:12px;border:1px solid var(--hvx-border);background:#fff;text-decoration:none;color:var(--hvx-slate);font-size:14px;font-weight:700;}\n  .hvx-cta a.primary{background:var(--hvx-slate);color:#fff;border-color:transparent;}\n  .hvx-badges{display:flex;flex-wrap:wrap;gap:8px;margin:10px 0 0}\n  .hvx-badge{font-size:12px;border:1px solid var(--hvx-border);border-radius:999px;padding:6px 10px;background:#fff;white-space:nowrap;}\n  .hvx-kv{display:grid;grid-template-columns:repeat(4,minmax(160px,1fr));gap:10px;margin-top:10px;}\n  .hvx-kv \u003e div{border:1px solid var(--hvx-border);background:#fff;border-radius:12px;padding:10px 12px;text-align:center;}\n  .hvx-kv strong{display:block}\n  .hvx-table{width:100%;border-collapse:collapse;min-width:520px;background:#fff;border:1px solid var(--hvx-border);border-radius:12px;overflow:hidden;}\n  .hvx-table th,.hvx-table td{border-bottom:1px solid var(--hvx-border);padding:10px 12px;vertical-align:top;font-size:14px;}\n  .hvx-table th{text-align:left;font-weight:800;background:#fff;}\n  .hvx-table tr:nth-child(even) td{background:#fbfaf6;}\n  .hvx-table tr:last-child td{border-bottom:none;}\n  .hvx-table-wrap{overflow:auto;border-radius:12px;}\n  .hvx-link{color:var(--hvx-slate);text-decoration:underline;text-underline-offset:2px}\n  .hvx-link:hover{opacity:.85}\n  details.hvx-faq{border:1px solid var(--hvx-border);background:#fff;border-radius:12px;padding:10px 12px;margin:8px 0;}\n  details.hvx-faq summary{cursor:pointer;font-weight:800}\n  @media(max-width:980px){.hvx-kv{grid-template-columns:repeat(2,minmax(160px,1fr))}}\n  @media(max-width:768px){.hvx-desc{padding:14px 12px 16px;border-radius:12px}.hvx-desc-header{padding:12px;border-radius:12px}.hvx-title{font-size:19px}.hvx-desc-card{padding:14px;margin:10px 0}}\n\u003c\/style\u003e\n\u003cdiv class=\"hvx-desc\"\u003e\n\u003cdiv class=\"hvx-desc-header\"\u003e\n\u003cdiv class=\"hvx-header-text\"\u003e\n\u003cdiv class=\"hvx-eyebrow\"\u003eBravo • Pisa Series • 12,000 BTU • Single Zone Heat Pump • R32 • 208-230V\u003c\/div\u003e\n\u003ch1 class=\"hvx-title\"\u003eBravo Pisa Series 12,000 BTU Single Zone Heat Pump System with Ceiling Cassette, 208-230V\u003c\/h1\u003e\n\u003cp class=\"hvx-subtitle\"\u003e\u003cstrong\u003eSKU:\u003c\/strong\u003e BRV-P12LS-230VO + BRV-P12CT-230VI\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv aria-label=\"Contact options\" class=\"hvx-cta\"\u003e\n\u003ca title=\"Contact Us\" rel=\"noopener\" href=\"https:\/\/hvacsupplies.com\/pages\/contact\" class=\"primary\" target=\"_blank\"\u003eCLICK HERE TO CONTACT US FOR CUSTOM QUOTES AND QUESTIONS\u003c\/a\u003e \u003ca title=\"Call Us Now!\" href=\"tel:+18005438933\"\u003eCLICK TO CALL US (800) 543-8933 FOR ANY QUESTIONS\u003c\/a\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"hvx-desc-card\"\u003e\n\u003ch2 class=\"hvx-section-title\"\u003eOverview\u003c\/h2\u003e\n\u003cp style=\"margin:0;\"\u003eThe Bravo Pisa Series \u003cstrong\u003e12,000 BTU\u003c\/strong\u003e heat pump system pairs the \u003cstrong\u003eBRV-P12LS-230VO outdoor unit\u003c\/strong\u003e with the \u003cstrong\u003eBRV-P12CT-230VI indoor unit\u003c\/strong\u003e to deliver dependable year-round comfort in a single-zone application. This pairing uses \u003cstrong\u003eR32 refrigerant\u003c\/strong\u003e, operates on \u003cstrong\u003e208-230V, 1Ph, 60Hz\u003c\/strong\u003e, and is designed around a clean ceiling cassette layout for rooms where wall space is limited.\u003c\/p\u003e\n\u003cp style=\"margin:10px 0 0;\"\u003eWith up to \u003cstrong\u003e22.0 SEER2\u003c\/strong\u003e, up to \u003cstrong\u003e9.5 EER2\u003c\/strong\u003e, and listed heating operation down to \u003cstrong\u003e-4~75°F\u003c\/strong\u003e, this system gives contractors and homeowners a compact option for efficient cooling and heating. Pairing, electrical requirements, drainage, and line set sizing should be verified before installation.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"hvx-desc-card\"\u003e\n\u003ch2 class=\"hvx-section-title\"\u003eHighlights\u003c\/h2\u003e\n\u003cdiv role=\"list\" class=\"hvx-badges\"\u003e\n\u003cspan role=\"listitem\" class=\"hvx-badge\"\u003e12,000 BTU class\u003c\/span\u003e \u003cspan role=\"listitem\" class=\"hvx-badge\"\u003eSingle-zone system\u003c\/span\u003e \u003cspan role=\"listitem\" class=\"hvx-badge\"\u003e208-230V, 1Ph, 60Hz\u003c\/span\u003e \u003cspan role=\"listitem\" class=\"hvx-badge\"\u003eR32 refrigerant\u003c\/span\u003e \u003cspan role=\"listitem\" class=\"hvx-badge\"\u003e22.0 SEER2\u003c\/span\u003e \u003cspan role=\"listitem\" class=\"hvx-badge\"\u003e9.5 EER2\u003c\/span\u003e \u003cspan role=\"listitem\" class=\"hvx-badge\"\u003eCeiling Cassette\u003c\/span\u003e \u003cspan role=\"listitem\" class=\"hvx-badge\"\u003eRemote Controller\u003c\/span\u003e \u003cspan role=\"listitem\" class=\"hvx-badge\"\u003eMax line length 49 ft\u003c\/span\u003e \u003cspan role=\"listitem\" class=\"hvx-badge\"\u003eHeating down to -4~75°F\u003c\/span\u003e\n\u003c\/div\u003e\n\u003cul style=\"margin:12px 0 0;padding-left:18px;\"\u003e\n\u003cli\u003e\n\u003cstrong\u003eSingle-zone comfort:\u003c\/strong\u003e One outdoor unit is paired with one indoor ceiling cassette for a dedicated zone.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEfficient R32 performance:\u003c\/strong\u003e Rated up to \u003cstrong\u003e22.0 SEER2\u003c\/strong\u003e and \u003cstrong\u003e9.5 EER2\u003c\/strong\u003e in the provided specifications.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFlexible indoor style:\u003c\/strong\u003e The \u003cstrong\u003eCeiling Cassette\u003c\/strong\u003e indoor unit is built for applications where a standard wall-mounted head is not the preferred fit.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eControl included:\u003c\/strong\u003e Includes a \u003cstrong\u003eRemote Controller\u003c\/strong\u003e for system operation.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLine set capability:\u003c\/strong\u003e Supports up to \u003cstrong\u003e49 ft\u003c\/strong\u003e maximum pipe length and \u003cstrong\u003e33 ft\u003c\/strong\u003e maximum level difference.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOperating range:\u003c\/strong\u003e Outdoor cooling range is \u003cstrong\u003e5~127°F\u003c\/strong\u003e, and outdoor heating range is \u003cstrong\u003e-4~75°F\u003c\/strong\u003e.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInstallation note:\u003c\/strong\u003e Installation kits are not included unless selected through the product variant options.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cdiv aria-label=\"At-a-glance\" role=\"list\" class=\"hvx-kv\"\u003e\n\u003cdiv role=\"listitem\"\u003e\n\u003cstrong\u003eIndoor\u003c\/strong\u003e BRV-P12CT-230VI\u003c\/div\u003e\n\u003cdiv role=\"listitem\"\u003e\n\u003cstrong\u003eOutdoor\u003c\/strong\u003e BRV-P12LS-230VO\u003c\/div\u003e\n\u003cdiv role=\"listitem\"\u003e\n\u003cstrong\u003eVoltage\u003c\/strong\u003e 208-230V, 1Ph, 60Hz\u003c\/div\u003e\n\u003cdiv role=\"listitem\"\u003e\n\u003cstrong\u003eRefrigerant\u003c\/strong\u003e R32\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"hvx-desc-card\"\u003e\n\u003ch2 class=\"hvx-section-title\"\u003eWhat's Included\u003c\/h2\u003e\n\u003cul style=\"padding-left:18px;margin:8px 0;\"\u003e\n\u003cli\u003eIndoor unit: BRV-P12CT-230VI\u003c\/li\u003e\n\u003cli\u003eOutdoor unit: BRV-P12LS-230VO\u003c\/li\u003e\n\u003cli\u003eRemote Controller\u003c\/li\u003e\n\u003cli\u003eInstallation kits are not included unless selected through the product variant options.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"hvx-desc-card\"\u003e\n\u003ch2 class=\"hvx-section-title\"\u003eIndoor Specs\u003c\/h2\u003e\n\u003cdiv class=\"hvx-table-wrap\"\u003e\u003ctable aria-label=\"Indoor unit specifications\" class=\"hvx-table\"\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eSpec\u003c\/th\u003e\n\u003cth\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBRV-P12CT-230VI\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower supply\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e208-230V, 1Ph, 60Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eVoltage range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e187-253\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCommunication wiring\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAWG 16x4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCooling capacity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e12,000 (2000~13600) BTU\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCooling input\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e980 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCooling rated current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4.3 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eHeating capacity at 47°F\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3100~12700 BTU\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eHeating input at 47°F\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e960 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eHeating rated current at 47°F\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4.2 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEER2\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e9.5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSEER2\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e22.0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCOP\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3.5 W\/W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eHSPF2-4\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e9.5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eHSPF2-5\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e8.9\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIndoor fan motor qty\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIndoor fan motor output\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e30 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIndoor fan motor RLA\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.13 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIndoor airflow\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e360\/320\/260\/200\/190 CFM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIndoor noise level\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e45\/43\/39\/35\/32 dB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDehumidification\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3.38 Pints\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDrain connection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.63\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRefrigerant piping\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1\/4 in. liquid, 3\/8 in. gas\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eController\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eRemote Controller\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRoom temperature range, cooling\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e62~89°F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRoom temperature range, heating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e32~86°F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFilter dimensions\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e23-3\/8\"x7-1\/4\"x1\/8\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePanel dimensions\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e25 -5\/8\"×25 -5\/8\"×1  -1\/8\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eUnit dimensions (W x D x H)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e22 -1\/2\"×22 -1\/2\"×10 -1\/4\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePacked dimensions (W x D x H)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e28 -1\/4\"×25 -7\/8\"×11 -7\/8\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNet \/ gross weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e31.9 lbs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDesign pressure\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e609\/174 PSIG\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"hvx-desc-card\"\u003e\n\u003ch2 class=\"hvx-section-title\"\u003eOutdoor Specs\u003c\/h2\u003e\n\u003cdiv class=\"hvx-table-wrap\"\u003e\u003ctable aria-label=\"Outdoor unit specifications\" class=\"hvx-table\"\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eSpec\u003c\/th\u003e\n\u003cth\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBRV-P12LS-230VO\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower supply\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e208-230V, 1Ph, 60Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eVoltage range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e187-253\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMinimum circuit ampacity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e11 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMaximum fuse\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e15 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCompressor model\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eWMO98SJ72-B01\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCompressor type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eRotary\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCompressor brand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eRechi\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCompressor capacity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e11942 BTU\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCompressor input\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e875 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCompressor rated current (RLA)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRefrigerant oil \/ charge\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e8.12 oz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOutdoor fan motor qty\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOutdoor fan motor output\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e33 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOutdoor fan motor RLA\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.15 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOutdoor fan speed\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1000 r\/min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOutdoor airflow\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e900 CFM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOutdoor noise level\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e55 dB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eThrottle type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCapillary\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRefrigerant type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eR32\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRefrigerant amount\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e20.46\/1.27\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFactory precharge\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e25 ft\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAdditional charge for 1\/4 in. liquid pipe\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.11 oz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRefrigerant piping\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1\/4 in. liquid, 3\/8 in. gas\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMaximum level difference\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e33 ft\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMaximum pipe length\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e49 ft\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAmbient range, cooling\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e5~127°F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAmbient range, heating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-4~75°F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eUnit dimensions (W x D x H)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e31 -1\/2\"×12\"×21 -3\/4\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePacked dimensions (W x D x H)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e32 -7\/8\"×13 -3\/8\"×23\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNet \/ gross weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e51.8 lbs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"hvx-desc-card\"\u003e\n\u003ch2 class=\"hvx-section-title\"\u003eDocuments \u0026amp; Downloads\u003c\/h2\u003e\n\u003cul style=\"padding-left:18px;margin:8px 0;\"\u003e\n\u003cli\u003eContact us for current submittals, installation documents, and compatibility questions before ordering or installation.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"hvx-desc-card\"\u003e\n\u003ch2 class=\"hvx-section-title\"\u003eImportant\u003c\/h2\u003e\n\u003cp style=\"margin:0;font-size:14px;color:var(--hvx-slate);\"\u003eProfessional installation is recommended. Verify electrical requirements, line set sizing, refrigerant charge, drainage, clearances, and local code requirements before installation. Installation kits are not included unless selected through the product variant options.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"hvx-desc-card\"\u003e\n\u003ch2 class=\"hvx-section-title\"\u003eFAQs\u003c\/h2\u003e\n\u003cdetails open=\"\" class=\"hvx-faq\"\u003e\u003csummary\u003eWhat refrigerant does this Bravo Pisa system use?\u003c\/summary\u003e\u003cdiv style=\"margin-top:8px;\"\u003eThis system uses R32 refrigerant.\u003c\/div\u003e\u003c\/details\u003e\n\u003cdetails open=\"\" class=\"hvx-faq\"\u003e\u003csummary\u003eWhat voltage does this system require?\u003c\/summary\u003e\u003cdiv style=\"margin-top:8px;\"\u003e208-230V, 1Ph, 60Hz.\u003c\/div\u003e\u003c\/details\u003e\n\u003cdetails open=\"\" class=\"hvx-faq\"\u003e\u003csummary\u003eIs this a single-zone system?\u003c\/summary\u003e\u003cdiv style=\"margin-top:8px;\"\u003eYes, this pairing is a single-zone system with one indoor unit and one outdoor unit.\u003c\/div\u003e\u003c\/details\u003e\n\u003cdetails open=\"\" class=\"hvx-faq\"\u003e\u003csummary\u003eWhat type of indoor unit is included?\u003c\/summary\u003e\u003cdiv style=\"margin-top:8px;\"\u003eThis listing includes a ceiling cassette indoor unit, model BRV-P12CT-230VI.\u003c\/div\u003e\u003c\/details\u003e\n\u003cdetails open=\"\" class=\"hvx-faq\"\u003e\u003csummary\u003eWhat controls are included?\u003c\/summary\u003e\u003cdiv style=\"margin-top:8px;\"\u003eThis system includes a Remote Controller.\u003c\/div\u003e\u003c\/details\u003e\n\u003cdetails open=\"\" class=\"hvx-faq\"\u003e\u003csummary\u003eWhat is the maximum line set length?\u003c\/summary\u003e\u003cdiv style=\"margin-top:8px;\"\u003eMaximum pipe length is 49 ft, with a maximum level difference of 33 ft.\u003c\/div\u003e\u003c\/details\u003e\n\u003cdetails open=\"\" class=\"hvx-faq\"\u003e\u003csummary\u003eIs an installation kit included?\u003c\/summary\u003e\u003cdiv style=\"margin-top:8px;\"\u003eInstallation kits are not included unless selected through the product variant options.\u003c\/div\u003e\u003c\/details\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e","brand":"Bravo","offers":[{"title":"Default Title","offer_id":44163933437995,"sku":"BRV-P12CT-230VI + BRV-P12LS-230VO","price":1216.8,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0625\/5647\/1339\/files\/bravo-pisa-12-000-btu-single-zone-ceiling-cassette-230v-r32-ductless-373.jpg?v=1783711646"}],"url":"https:\/\/hvacsupplies.com\/collections\/single-zone-four-way-ceiling-cassette-12k-15k.oembed","provider":"HVACSupplies.com","version":"1.0","type":"link"}