{"title":"Ductless Multi-zone Standard Outdoor Units Cooper\u0026Hunter","description":null,"products":[{"product_id":"cooper-hunter-multi-zone-r454b-outdoor-condenser-18-000-btu-1-5-ton","title":"Cooper\u0026Hunter Multi-Zone R454B Outdoor Condenser 18,000 BTU (1.5 Ton)","description":"\u003cstyle\u003e\n  :root{\n    --hvx-golden:#FAA819;\n    --hvx-slate:#262626;\n    --hvx-ivory:#F4F1E6;\n    --hvx-border:#e2e0d5;\n    --hvx-card-bg:#ffffff;\n  }\n\n  .hvx-desc{\n    font-family:\"Articulat CF\",system-ui,-apple-system,BlinkMacSystemFont,\"Segoe UI\",sans-serif;\n    color:var(--hvx-slate);\n    line-height:1.6;\n    background:var(--hvx-ivory);\n    padding:18px 18px 20px;\n    border-radius:16px;\n  }\n\n  .hvx-desc-header{\n    border-radius:14px;\n    padding:14px 16px;\n    background:linear-gradient(120deg,var(--hvx-golden),var(--hvx-slate));\n    color:#fff;\n    margin:0 0 16px;\n    box-shadow:0 10px 24px rgba(0,0,0,.22);\n    display:flex;\n    align-items:flex-start;\n    gap:12px;\n    flex-wrap:wrap;\n  }\n\n  .hvx-header-text{display:flex;flex-direction:column;gap:4px;min-width:260px}\n  .hvx-eyebrow{\n    font-size:11px;\n    letter-spacing:.14em;\n    text-transform:uppercase;\n    opacity:.9;\n  }\n  .hvx-title{\n    margin:0;\n    font-family:\"Anton\",\"Impact\",system-ui,-apple-system,BlinkMacSystemFont,\"Segoe UI\",sans-serif;\n    font-size:22px;\n    line-height:1.15;\n  }\n\n  .hvx-desc-card{\n    border:1px solid var(--hvx-border);\n    border-radius:14px;\n    background:var(--hvx-card-bg);\n    padding:16px 18px 18px;\n    box-shadow:0 4px 12px rgba(0,0,0,.06);\n    margin:14px 0;\n  }\n\n  .hvx-section-title{\n    margin:0 0 10px;\n    font-family:\"Anton\",\"Impact\",system-ui,-apple-system,BlinkMacSystemFont,\"Segoe UI\",sans-serif;\n    font-size:17px;\n    letter-spacing:.08em;\n    text-transform:uppercase;\n    color:var(--hvx-slate);\n    display:inline-flex;\n    align-items:center;\n    gap:8px;\n  }\n  .hvx-section-title::after{\n    content:\"\";\n    flex:1;\n    height:2px;\n    border-radius:999px;\n    background:linear-gradient(90deg,var(--hvx-golden),transparent);\n    opacity:.9;\n  }\n\n  .hvx-cta{display:flex;flex-wrap:wrap;gap:10px;margin:10px 0 0}\n  .hvx-cta a{\n    display:inline-flex;\n    align-items:center;\n    gap:8px;\n    padding:10px 14px;\n    border-radius:12px;\n    border:1px solid var(--hvx-border);\n    background:#fff;\n    text-decoration:none;\n    color:var(--hvx-slate);\n    font-size:14px;\n    font-weight:700;\n  }\n  .hvx-cta a.primary{\n    background:var(--hvx-slate);\n    color:#fff;\n    border-color:transparent;\n  }\n\n  .hvx-badges{display:flex;flex-wrap:wrap;gap:8px;margin:10px 0 0}\n  .hvx-badge{\n    font-size:12px;\n    border:1px solid var(--hvx-border);\n    border-radius:999px;\n    padding:6px 10px;\n    background:#fff;\n    white-space:nowrap;\n  }\n\n  .hvx-kv{\n    display:grid;\n    grid-template-columns:repeat(4,minmax(160px,1fr));\n    gap:10px;\n    margin-top:10px;\n  }\n  .hvx-kv \u003e div{\n    border:1px solid var(--hvx-border);\n    background:#fff;\n    border-radius:12px;\n    padding:10px 12px;\n    text-align:center;\n  }\n  .hvx-kv strong{display:block}\n\n  .hvx-table{\n    width:100%;\n    border-collapse:collapse;\n    min-width:520px;\n    background:#fff;\n    border:1px solid var(--hvx-border);\n    border-radius:12px;\n    overflow:hidden;\n  }\n  .hvx-table th,.hvx-table td{\n    border-bottom:1px solid var(--hvx-border);\n    padding:10px 12px;\n    vertical-align:top;\n    font-size:14px;\n  }\n  .hvx-table th{ text-align:left; font-weight:800; background:#fff; }\n  .hvx-table tr:nth-child(odd) td{ background:#fff; }\n  .hvx-table tr:nth-child(even) td{ background:#fbfaf6; }\n  .hvx-table tr:last-child td{ border-bottom:none; }\n  .hvx-table-wrap{ overflow:auto; border-radius:12px; }\n\n  .hvx-note{\n    font-size:12px;\n    color:#555;\n    margin:10px 0 0;\n  }\n\n  details.hvx-faq{\n    border:1px solid var(--hvx-border);\n    background:#fff;\n    border-radius:12px;\n    padding:10px 12px;\n    margin:8px 0;\n  }\n  details.hvx-faq summary{\n    cursor:pointer;\n    font-weight:800;\n  }\n\n  @media(max-width:980px){\n    .hvx-kv{grid-template-columns:repeat(2,minmax(160px,1fr))}\n  }\n  @media(max-width:768px){\n    .hvx-desc{padding:14px 12px 16px;border-radius:12px}\n    .hvx-desc-header{padding:12px;border-radius:12px}\n    .hvx-title{font-size:19px}\n    .hvx-desc-card{padding:14px;margin:10px 0}\n  }\n\u003c\/style\u003e\n\n\u003cdiv class=\"hvx-desc\"\u003e\n  \u003cdiv class=\"hvx-desc-header\"\u003e\n    \u003cdiv class=\"hvx-header-text\"\u003e\n      \u003cdiv class=\"hvx-eyebrow\"\u003eCooper\u0026amp;Hunter Hyper Multi-Zone Outdoor • R454B • Multi-Zone\u003c\/div\u003e\n      \u003ch1 class=\"hvx-title\"\u003eCooper\u0026amp;Hunter Hyper Multi-Zone Outdoor — 18,000 BTU, R454B — CH-R18MES-230VO\u003c\/h1\u003e\n    \u003c\/div\u003e\n  \u003c\/div\u003e\n\n  \u003cdiv aria-label=\"Contact options\" class=\"hvx-cta\"\u003e\n    \u003ca title=\"Contact Us\" rel=\"noopener\" href=\"https:\/\/hvacsupplies.com\/pages\/contact\" class=\"primary\" target=\"_blank\"\u003e\n      CLICK HERE TO CONTACT US FOR CUSTOM QUOTES AND QUESTIONS\n    \u003c\/a\u003e\n    \u003ca title=\"Call Us Now!\" href=\"tel:+18005438933\"\u003e\n      CLICK TO CALL US 1-800-543-8933 FOR ANY QUESTIONS\n    \u003c\/a\u003e\n    \u003cbr\u003e\n  \u003c\/div\u003e\n\n  \u003cdiv class=\"hvx-desc-card\"\u003e\n    \u003ch2 class=\"hvx-section-title\"\u003eOverview\u003c\/h2\u003e\n    \u003cp style=\"margin:0;\"\u003e\n      Cooper\u0026amp;Hunter’s 18K BTU Hyper Multi-Zone outdoor unit is built for efficient, flexible comfort in residential\n      spaces. It supports up to three zones for independent room-by-room control and uses advanced inverter technology\n      to modulate compressor speed for steady performance and lower energy use. With up to 25.1 SEER2 efficiency and\n      R454B refrigerant (lower GWP vs. many conventional options), it’s a strong fit for modern, eco-conscious multi-zone\n      installations.\n    \u003c\/p\u003e\n  \u003c\/div\u003e\n\n  \u003cdiv class=\"hvx-desc-card\"\u003e\n    \u003ch2 class=\"hvx-section-title\"\u003eHighlights\u003c\/h2\u003e\n\n    \u003cdiv role=\"list\" class=\"hvx-badges\"\u003e\n      \u003cspan role=\"listitem\" class=\"hvx-badge\"\u003e18,000 BTU cool (5,400–21,600)\u003c\/span\u003e\n      \u003cspan role=\"listitem\" class=\"hvx-badge\"\u003e19,000 BTU heat (5,700–21,600)\u003c\/span\u003e\n      \u003cspan role=\"listitem\" class=\"hvx-badge\"\u003eUp to 3 zones\u003c\/span\u003e\n      \u003cspan role=\"listitem\" class=\"hvx-badge\"\u003eSEER2 25.1 · EER2 14\u003c\/span\u003e\n      \u003cspan role=\"listitem\" class=\"hvx-badge\"\u003eHSPF2 9.8 (Region IV) · 7.8 (Region V)\u003c\/span\u003e\n      \u003cspan role=\"listitem\" class=\"hvx-badge\"\u003eCOP 3.8\u003c\/span\u003e\n      \u003cspan role=\"listitem\" class=\"hvx-badge\"\u003eR454B\u003c\/span\u003e\n      \u003cspan role=\"listitem\" class=\"hvx-badge\"\u003e208–230V 1Ph\u003c\/span\u003e\n      \u003cspan role=\"listitem\" class=\"hvx-badge\"\u003e−13–122 °F cool · −13–75 °F heat\u003c\/span\u003e\n    \u003c\/div\u003e\n\n    \u003cul style=\"margin: 12px 0 0; padding-left: 18px;\"\u003e\n      \u003cli\u003e\n\u003cstrong\u003eMulti-zone flexibility:\u003c\/strong\u003e supports up to 3 independent zones with compatible indoor units.\u003c\/li\u003e\n      \u003cli\u003e\n\u003cstrong\u003eHigh efficiency:\u003c\/strong\u003e up to 25.1 SEER2 for strong seasonal energy savings.\u003c\/li\u003e\n      \u003cli\u003e\n\u003cstrong\u003eInverter performance:\u003c\/strong\u003e precise compressor modulation for stable comfort and reduced operating cost.\u003c\/li\u003e\n      \u003cli\u003e\n\u003cstrong\u003eEco-forward refrigerant:\u003c\/strong\u003e uses R454B to reduce environmental impact.\u003c\/li\u003e\n      \u003cli\u003e\n\u003cstrong\u003eCompact \u0026amp; practical:\u003c\/strong\u003e designed for easier placement where space is limited.\u003c\/li\u003e\n    \u003c\/ul\u003e\n\n    \u003cdiv aria-label=\"At-a-glance\" role=\"list\" class=\"hvx-kv\"\u003e\n      \u003cdiv role=\"listitem\"\u003e\n\u003cstrong\u003eModel\u003c\/strong\u003eCH-R18MES-230VO\u003c\/div\u003e\n      \u003cdiv role=\"listitem\"\u003e\n\u003cstrong\u003eZones\u003c\/strong\u003eUp to 3\u003c\/div\u003e\n      \u003cdiv role=\"listitem\"\u003e\n\u003cstrong\u003eOutdoor Sound\u003c\/strong\u003e59.5 dB(A)\u003c\/div\u003e\n      \u003cdiv role=\"listitem\"\u003e\n\u003cstrong\u003eLines\u003c\/strong\u003e3× 1\/4″ liquid · 3× 3\/8″ gas\u003c\/div\u003e\n    \u003c\/div\u003e\n  \u003c\/div\u003e\n\n  \u003cdiv class=\"hvx-desc-card\"\u003e\n    \u003ch2 class=\"hvx-section-title\"\u003eWhat's Included\u003c\/h2\u003e\n    \u003cul style=\"padding-left: 18px; margin: 8px 0;\"\u003e\n      \u003cli\u003eOutdoor unit CH-R18MES-230VO\u003c\/li\u003e\n      \u003cli\u003eOwner \/ installation documentation\u003c\/li\u003e\n    \u003c\/ul\u003e\n    \u003cp class=\"hvx-note\"\u003ePair only with compatible Cooper\u0026amp;Hunter Hyper Multi-Zone indoor units. Match zone combinations and piping requirements before installation.\u003c\/p\u003e\n  \u003c\/div\u003e\n\n  \u003cdiv class=\"hvx-desc-card\"\u003e\n    \u003ch2 class=\"hvx-section-title\"\u003eIndoor Specs\u003c\/h2\u003e\n    \u003cdiv class=\"hvx-table-wrap\"\u003e\n      \u003ctable aria-label=\"Indoor unit compatibility\" class=\"hvx-table\"\u003e\n        \u003cthead\u003e\n          \u003ctr\u003e\n\u003cth\u003eSpec\u003c\/th\u003e\n\u003cth\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\n        \u003c\/thead\u003e\n        \u003ctbody\u003e\n          \u003ctr\u003e\n            \u003ctd\u003e\u003cstrong\u003eSystem type\u003c\/strong\u003e\u003c\/td\u003e\n            \u003ctd\u003eMulti-zone unit (outdoor)\u003c\/td\u003e\n          \u003c\/tr\u003e\n          \u003ctr\u003e\n            \u003ctd\u003e\u003cstrong\u003eZones supported\u003c\/strong\u003e\u003c\/td\u003e\n            \u003ctd\u003eUp to 3 independent zones (depends on indoor unit selection)\u003c\/td\u003e\n          \u003c\/tr\u003e\n          \u003ctr\u003e\n            \u003ctd\u003e\u003cstrong\u003eCompatible indoor units\u003c\/strong\u003e\u003c\/td\u003e\n            \u003ctd\u003eCooper\u0026amp;Hunter Hyper Multi-Zone indoor units (zone mix varies by combination)\u003c\/td\u003e\n          \u003c\/tr\u003e\n          \u003ctr\u003e\n            \u003ctd\u003e\u003cstrong\u003eRefrigerant piping (per zone)\u003c\/strong\u003e\u003c\/td\u003e\n            \u003ctd\u003e1\/4″ liquid · 3\/8″ gas (3 circuits)\u003c\/td\u003e\n          \u003c\/tr\u003e\n          \u003ctr\u003e\n            \u003ctd\u003e\u003cstrong\u003eMax height difference (IDU↔ODU)\u003c\/strong\u003e\u003c\/td\u003e\n            \u003ctd\u003e49.2 ft\u003c\/td\u003e\n          \u003c\/tr\u003e\n          \u003ctr\u003e\n            \u003ctd\u003e\u003cstrong\u003eCombination guidance\u003c\/strong\u003e\u003c\/td\u003e\n            \u003ctd\u003eUse the provided Multi-Zone Combination PDFs to confirm valid indoor mixes\u003c\/td\u003e\n          \u003c\/tr\u003e\n        \u003c\/tbody\u003e\n      \u003c\/table\u003e\n    \u003c\/div\u003e\n    \u003cp class=\"hvx-note\"\u003eIndoor-unit capacities, features, and controls depend on the specific indoor models selected for each zone.\u003c\/p\u003e\n  \u003c\/div\u003e\n\n  \u003cdiv class=\"hvx-desc-card\"\u003e\n    \u003ch2 class=\"hvx-section-title\"\u003eOutdoor Specs\u003c\/h2\u003e\n    \u003cdiv class=\"hvx-table-wrap\"\u003e\n      \u003ctable aria-label=\"Outdoor unit specifications\" class=\"hvx-table\"\u003e\n        \u003cthead\u003e\n          \u003ctr\u003e\n\u003cth\u003eSpec\u003c\/th\u003e\n\u003cth\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\n        \u003c\/thead\u003e\n        \u003ctbody\u003e\n          \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCH-R18MES-230VO\u003c\/td\u003e\n\u003c\/tr\u003e\n          \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRefrigerant type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eR454B\u003c\/td\u003e\n\u003c\/tr\u003e\n          \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower source\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e208–230V, 1Ph, 60Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n          \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eVoltage range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e187–253 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\n          \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCooling capacity (Min\/Max)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e18,000 BTU\/h (5,400–21,600)\u003c\/td\u003e\n\u003c\/tr\u003e\n          \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eHeating capacity (Min\/Max)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e19,000 BTU\/h (5,700–21,600)\u003c\/td\u003e\n\u003c\/tr\u003e\n\n          \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSEER2 \/ EER2\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e25.1 \/ 14\u003c\/td\u003e\n\u003c\/tr\u003e\n          \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eHSPF2-4 \/ HSPF2-5\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e9.8 \/ 7.8\u003c\/td\u003e\n\u003c\/tr\u003e\n          \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCOP\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3.8\u003c\/td\u003e\n\u003c\/tr\u003e\n\n          \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMinimum circuit ampacity (MCA)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e16 A\u003c\/td\u003e\n\u003c\/tr\u003e\n          \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMax fuse\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e20 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\n          \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOutdoor Air Flow\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1,765.8 CFM\u003c\/td\u003e\n\u003c\/tr\u003e\n          \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOutdoor Noise Level\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e59.5 dB(A)\u003c\/td\u003e\n\u003c\/tr\u003e\n          \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDehumidification\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.42 pints\/day\u003c\/td\u003e\n\u003c\/tr\u003e\n\n          \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eUnit dimensions (W×H×D)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e35.04 × 13.46 × 26.50 in\u003c\/td\u003e\n\u003c\/tr\u003e\n          \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePacking dimensions (W×D×H)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e40.55 × 17.24 × 29.53 in\u003c\/td\u003e\n\u003c\/tr\u003e\n          \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNet \/ Gross weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e100.53 \/ 109.35 lb\u003c\/td\u003e\n\u003c\/tr\u003e\n\n          \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRefrigerant precharge\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e75 (factory charge)\u003c\/td\u003e\n\u003c\/tr\u003e\n          \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRefrigerant piping (Liquid\/Gas)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3× 1\/4″ · 3× 3\/8″\u003c\/td\u003e\n\u003c\/tr\u003e\n\n          \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAmbient temperature — Heating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e−13 to 75 °F\u003c\/td\u003e\n\u003c\/tr\u003e\n          \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAmbient temperature — Cooling\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e−13 to 122 °F\u003c\/td\u003e\n\u003c\/tr\u003e\n\n          \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAdditional refrigerant charge — 3\/8″ liquid line\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.32\u003c\/td\u003e\n\u003c\/tr\u003e\n          \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAdditional refrigerant charge — 1\/4″ liquid line\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.16\u003c\/td\u003e\n\u003c\/tr\u003e\n        \u003c\/tbody\u003e\n      \u003c\/table\u003e\n    \u003c\/div\u003e\n  \u003c\/div\u003e\n\n  \u003cdiv class=\"hvx-desc-card\"\u003e\n    \u003ch2 class=\"hvx-section-title\"\u003eDocuments \u0026amp; Downloads\u003c\/h2\u003e\n    \u003cul style=\"padding-left: 18px; margin: 8px 0;\"\u003e\n      \u003cli\u003e\u003ca rel=\"noopener\" href=\"https:\/\/media.cooperandhunter.us\/4443\/CH-R18MES-230VO.pdf\" target=\"_blank\"\u003eCH-R18MES-230VO Submittal (PDF)\u003c\/a\u003e\u003c\/li\u003e\n      \u003cli\u003e\u003ca rel=\"noopener\" href=\"https:\/\/media.cooperandhunter.us\/4444\/CH-R18MES-230VO-non.pdf\" target=\"_blank\"\u003eCH-R18MES-230VO Submittal — Non-Ducted (PDF)\u003c\/a\u003e\u003c\/li\u003e\n      \u003cli\u003e\u003ca rel=\"noopener\" href=\"https:\/\/media.cooperandhunter.us\/4442\/Installation-manual-Multi-R.pdf\" target=\"_blank\"\u003eInstallation Manual — Multi-R (PDF)\u003c\/a\u003e\u003c\/li\u003e\n      \u003cli\u003e\u003ca rel=\"noopener\" href=\"https:\/\/media.cooperandhunter.us\/3198\/MultiZone-Combination-HYPER.pdf\" target=\"_blank\"\u003eMulti-Zone Combination — HYPER (PDF)\u003c\/a\u003e\u003c\/li\u003e\n      \u003cli\u003e\u003ca rel=\"noopener\" href=\"https:\/\/media.cooperandhunter.us\/3199\/MultiZone-Combination-Regular.pdf\" target=\"_blank\"\u003eMulti-Zone Combination — Regular (PDF)\u003c\/a\u003e\u003c\/li\u003e\n    \u003c\/ul\u003e\n    \u003cp class=\"hvx-note\"\u003eAHRI certification numbers (reference): Ducted 215864254 · Non-Ducted 215864255 · Mixed 215864256.\u003c\/p\u003e\n  \u003c\/div\u003e\n\n  \u003cdiv class=\"hvx-desc-card\"\u003e\n    \u003ch2 class=\"hvx-section-title\"\u003eImportant\u003c\/h2\u003e\n    \u003cp style=\"font-size: 14px; color: var(--hvx-slate); margin: 0;\" class=\"hvx-note\"\u003e\n      Install by a licensed HVAC professional. Confirm indoor unit combinations, voltage range (187–253 V), MCA\/max-fuse,\n      refrigerant piping per zone, height limits, and ambient operating ranges before commissioning.\n    \u003c\/p\u003e\n  \u003c\/div\u003e\n\n  \u003cdiv class=\"hvx-desc-card\"\u003e\n    \u003ch2 class=\"hvx-section-title\"\u003eFAQs\u003c\/h2\u003e\n\n    \u003cdetails open class=\"hvx-faq\"\u003e\n      \u003csummary\u003eHow many zones can this support?\u003c\/summary\u003e\n      \u003cdiv style=\"margin-top: 8px;\"\u003eUp to three independent zones with compatible Cooper\u0026amp;Hunter Hyper Multi-Zone indoor units.\u003c\/div\u003e\n    \u003c\/details\u003e\n\n    \u003cdetails open class=\"hvx-faq\"\u003e\n      \u003csummary\u003eWhat line sizes are required?\u003c\/summary\u003e\n      \u003cdiv style=\"margin-top: 8px;\"\u003eThree circuits total: 3× 1\/4″ liquid and 3× 3\/8″ gas connections.\u003c\/div\u003e\n    \u003c\/details\u003e\n\n    \u003cdetails open class=\"hvx-faq\"\u003e\n      \u003csummary\u003eWhat are the power requirements?\u003c\/summary\u003e\n      \u003cdiv style=\"margin-top: 8px;\"\u003e208–230 V, single-phase, 60 Hz. Voltage range 187–253 V. MCA 16 A. Max fuse 20 A.\u003c\/div\u003e\n    \u003c\/details\u003e\n\n    \u003cdetails open class=\"hvx-faq\"\u003e\n      \u003csummary\u003eWhat refrigerant does it use?\u003c\/summary\u003e\n      \u003cdiv style=\"margin-top: 8px;\"\u003eR454B.\u003c\/div\u003e\n    \u003c\/details\u003e\n\n    \u003cdetails open class=\"hvx-faq\"\u003e\n      \u003csummary\u003eWhat are the operating temperature ranges?\u003c\/summary\u003e\n      \u003cdiv style=\"margin-top: 8px;\"\u003eCooling: −13 to 122 °F. Heating: −13 to 75 °F.\u003c\/div\u003e\n    \u003c\/details\u003e\n\n    \u003cdetails open class=\"hvx-faq\"\u003e\n      \u003csummary\u003eHow efficient is this outdoor unit?\u003c\/summary\u003e\n      \u003cdiv style=\"margin-top: 8px;\"\u003eRated up to 25.1 SEER2 and 14 EER2. HSPF2 is 9.8 (Region IV) \/ 7.8 (Region V).\u003c\/div\u003e\n    \u003c\/details\u003e\n  \u003c\/div\u003e\n\u003c\/div\u003e\n","brand":"Cooper\u0026Hunter","offers":[{"title":"Default Title","offer_id":42697595256875,"sku":"CH-R18MES-230VO","price":1580.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0625\/5647\/1339\/files\/36000BTU_c5d505e7-64c5-4441-ba6b-29b3483de2f2.png?v=1769190457"},{"product_id":"cooper-hunter-multi-zone-r454b-outdoor-condenser-28-000-btu-2-33-ton","title":"Cooper\u0026Hunter Multi-Zone R454B Outdoor Condenser 28,000 BTU (2.33 Ton)","description":"\u003cstyle\u003e\n  :root{\n    --hvx-golden:#FAA819;\n    --hvx-slate:#262626;\n    --hvx-ivory:#F4F1E6;\n    --hvx-border:#e2e0d5;\n    --hvx-card-bg:#ffffff;\n  }\n\n  .hvx-desc{\n    font-family:\"Articulat CF\",system-ui,-apple-system,BlinkMacSystemFont,\"Segoe UI\",sans-serif;\n    color:var(--hvx-slate);\n    line-height:1.6;\n    background:var(--hvx-ivory);\n    padding:18px 18px 20px;\n    border-radius:16px;\n  }\n\n  .hvx-desc-header{\n    border-radius:14px;\n    padding:14px 16px;\n    background:linear-gradient(120deg,var(--hvx-golden),var(--hvx-slate));\n    color:#fff;\n    margin:0 0 16px;\n    box-shadow:0 10px 24px rgba(0,0,0,.22);\n    display:flex;\n    align-items:flex-start;\n    gap:12px;\n    flex-wrap:wrap;\n  }\n\n  .hvx-header-text{display:flex;flex-direction:column;gap:4px;min-width:260px}\n  .hvx-eyebrow{\n    font-size:11px;\n    letter-spacing:.14em;\n    text-transform:uppercase;\n    opacity:.9;\n  }\n  .hvx-title{\n    margin:0;\n    font-family:\"Anton\",\"Impact\",system-ui,-apple-system,BlinkMacSystemFont,\"Segoe UI\",sans-serif;\n    font-size:22px;\n    line-height:1.15;\n  }\n\n  .hvx-desc-card{\n    border:1px solid var(--hvx-border);\n    border-radius:14px;\n    background:var(--hvx-card-bg);\n    padding:16px 18px 18px;\n    box-shadow:0 4px 12px rgba(0,0,0,.06);\n    margin:14px 0;\n  }\n\n  .hvx-section-title{\n    margin:0 0 10px;\n    font-family:\"Anton\",\"Impact\",system-ui,-apple-system,BlinkMacSystemFont,\"Segoe UI\",sans-serif;\n    font-size:17px;\n    letter-spacing:.08em;\n    text-transform:uppercase;\n    color:var(--hvx-slate);\n    display:inline-flex;\n    align-items:center;\n    gap:8px;\n  }\n  .hvx-section-title::after{\n    content:\"\";\n    flex:1;\n    height:2px;\n    border-radius:999px;\n    background:linear-gradient(90deg,var(--hvx-golden),transparent);\n    opacity:.9;\n  }\n\n  .hvx-cta{display:flex;flex-wrap:wrap;gap:10px;margin:10px 0 0}\n  .hvx-cta a{\n    display:inline-flex;\n    align-items:center;\n    gap:8px;\n    padding:10px 14px;\n    border-radius:12px;\n    border:1px solid var(--hvx-border);\n    background:#fff;\n    text-decoration:none;\n    color:var(--hvx-slate);\n    font-size:14px;\n    font-weight:700;\n  }\n  .hvx-cta a.primary{\n    background:var(--hvx-slate);\n    color:#fff;\n    border-color:transparent;\n  }\n\n  .hvx-badges{display:flex;flex-wrap:wrap;gap:8px;margin:10px 0 0}\n  .hvx-badge{\n    font-size:12px;\n    border:1px solid var(--hvx-border);\n    border-radius:999px;\n    padding:6px 10px;\n    background:#fff;\n    white-space:nowrap;\n  }\n\n  .hvx-kv{\n    display:grid;\n    grid-template-columns:repeat(4,minmax(160px,1fr));\n    gap:10px;\n    margin-top:10px;\n  }\n  .hvx-kv \u003e div{\n    border:1px solid var(--hvx-border);\n    background:#fff;\n    border-radius:12px;\n    padding:10px 12px;\n    text-align:center;\n  }\n  .hvx-kv strong{display:block}\n\n  .hvx-table{\n    width:100%;\n    border-collapse:collapse;\n    min-width:520px;\n    background:#fff;\n    border:1px solid var(--hvx-border);\n    border-radius:12px;\n    overflow:hidden;\n  }\n  .hvx-table th,.hvx-table td{\n    border-bottom:1px solid var(--hvx-border);\n    padding:10px 12px;\n    vertical-align:top;\n    font-size:14px;\n  }\n  .hvx-table th{ text-align:left; font-weight:800; background:#fff; }\n  .hvx-table tr:nth-child(odd) td{ background:#fff; }\n  .hvx-table tr:nth-child(even) td{ background:#fbfaf6; }\n  .hvx-table tr:last-child td{ border-bottom:none; }\n  .hvx-table-wrap{ overflow:auto; border-radius:12px; }\n\n  .hvx-note{\n    font-size:12px;\n    color:#555;\n    margin:10px 0 0;\n  }\n\n  details.hvx-faq{\n    border:1px solid var(--hvx-border);\n    background:#fff;\n    border-radius:12px;\n    padding:10px 12px;\n    margin:8px 0;\n  }\n  details.hvx-faq summary{\n    cursor:pointer;\n    font-weight:800;\n  }\n\n  @media(max-width:980px){\n    .hvx-kv{grid-template-columns:repeat(2,minmax(160px,1fr))}\n  }\n  @media(max-width:768px){\n    .hvx-desc{padding:14px 12px 16px;border-radius:12px}\n    .hvx-desc-header{padding:12px;border-radius:12px}\n    .hvx-title{font-size:19px}\n    .hvx-desc-card{padding:14px;margin:10px 0}\n  }\n\u003c\/style\u003e\n\n\u003cdiv class=\"hvx-desc\"\u003e\n  \u003cdiv class=\"hvx-desc-header\"\u003e\n    \u003cdiv class=\"hvx-header-text\"\u003e\n      \u003cdiv class=\"hvx-eyebrow\"\u003eCooper\u0026amp;Hunter Hyper Multi-Zone Outdoor • R454B • Multi-Zone\u003c\/div\u003e\n      \u003ch1 class=\"hvx-title\"\u003eCooper\u0026amp;Hunter Hyper Multi-Zone Outdoor — 28,000 BTU, R454B — CH-R28MES-230VO\u003c\/h1\u003e\n    \u003c\/div\u003e\n  \u003c\/div\u003e\n\n  \u003cdiv aria-label=\"Contact options\" class=\"hvx-cta\"\u003e\n    \u003ca title=\"Contact Us\" rel=\"noopener\" href=\"https:\/\/hvacsupplies.com\/pages\/contact\" class=\"primary\" target=\"_blank\"\u003e\n      CLICK HERE TO CONTACT US FOR CUSTOM QUOTES AND QUESTIONS\n    \u003c\/a\u003e\n    \u003ca title=\"Call Us Now!\" href=\"tel:+18005438933\"\u003e\n      CLICK TO CALL US 1-800-543-8933 FOR ANY QUESTIONS\n    \u003c\/a\u003e\n    \u003cbr\u003e\n  \u003c\/div\u003e\n\n  \u003cdiv class=\"hvx-desc-card\"\u003e\n    \u003ch2 class=\"hvx-section-title\"\u003eOverview\u003c\/h2\u003e\n    \u003cp style=\"margin:0;\"\u003e\n      Cooper\u0026amp;Hunter’s 28K BTU Hyper Multi-Zone outdoor unit is a highly adaptable, efficient system built to deliver\n      personalized comfort across residential spaces. Supporting up to four zones, it enables independent temperature\n      control in multiple rooms. Advanced inverter technology dynamically adjusts compressor output to match demand,\n      optimizing energy use while maintaining reliable performance. With up to 25 SEER2 efficiency and R454B refrigerant\n      (lower GWP vs. many conventional options), it’s a strong fit for modern, eco-conscious multi-zone installations.\n    \u003c\/p\u003e\n  \u003c\/div\u003e\n\n  \u003cdiv class=\"hvx-desc-card\"\u003e\n    \u003ch2 class=\"hvx-section-title\"\u003eHighlights\u003c\/h2\u003e\n\n    \u003cdiv role=\"list\" class=\"hvx-badges\"\u003e\n      \u003cspan role=\"listitem\" class=\"hvx-badge\"\u003e27,000 BTU cool (7,200–32,000)\u003c\/span\u003e\n      \u003cspan role=\"listitem\" class=\"hvx-badge\"\u003e27,000 BTU heat (8,400–29,000)\u003c\/span\u003e\n      \u003cspan role=\"listitem\" class=\"hvx-badge\"\u003eUp to 4 zones\u003c\/span\u003e\n      \u003cspan role=\"listitem\" class=\"hvx-badge\"\u003eSEER2 25 · EER2 13\u003c\/span\u003e\n      \u003cspan role=\"listitem\" class=\"hvx-badge\"\u003eHSPF2 9.5 (Region IV) · 7.4 (Region V)\u003c\/span\u003e\n      \u003cspan role=\"listitem\" class=\"hvx-badge\"\u003eCOP 3.8\u003c\/span\u003e\n      \u003cspan role=\"listitem\" class=\"hvx-badge\"\u003eR454B\u003c\/span\u003e\n      \u003cspan role=\"listitem\" class=\"hvx-badge\"\u003e208–230V 1Ph\u003c\/span\u003e\n      \u003cspan role=\"listitem\" class=\"hvx-badge\"\u003e−13–122 °F cool · −13–75 °F heat\u003c\/span\u003e\n    \u003c\/div\u003e\n\n    \u003cul style=\"margin: 12px 0 0; padding-left: 18px;\"\u003e\n      \u003cli\u003e\n\u003cstrong\u003eMulti-zone flexibility:\u003c\/strong\u003e supports up to 4 independent zones with compatible indoor units.\u003c\/li\u003e\n      \u003cli\u003e\n\u003cstrong\u003eHigh efficiency:\u003c\/strong\u003e up to 25 SEER2 for strong seasonal energy savings.\u003c\/li\u003e\n      \u003cli\u003e\n\u003cstrong\u003eInverter performance:\u003c\/strong\u003e dynamic compressor modulation for stable comfort and reduced operating cost.\u003c\/li\u003e\n      \u003cli\u003e\n\u003cstrong\u003eEco-forward refrigerant:\u003c\/strong\u003e uses R454B to reduce environmental impact.\u003c\/li\u003e\n      \u003cli\u003e\n\u003cstrong\u003eCompact \u0026amp; install-friendly:\u003c\/strong\u003e space-efficient footprint helps with tighter placements.\u003c\/li\u003e\n    \u003c\/ul\u003e\n\n    \u003cdiv aria-label=\"At-a-glance\" role=\"list\" class=\"hvx-kv\"\u003e\n      \u003cdiv role=\"listitem\"\u003e\n\u003cstrong\u003eModel\u003c\/strong\u003eCH-R28MES-230VO\u003c\/div\u003e\n      \u003cdiv role=\"listitem\"\u003e\n\u003cstrong\u003eZones\u003c\/strong\u003eUp to 4\u003c\/div\u003e\n      \u003cdiv role=\"listitem\"\u003e\n\u003cstrong\u003eOutdoor Sound\u003c\/strong\u003e61 dB(A)\u003c\/div\u003e\n      \u003cdiv role=\"listitem\"\u003e\n\u003cstrong\u003eLines\u003c\/strong\u003e4× 1\/4″ liquid · (3× 3\/8″ + 1× 1\/2″) gas\u003c\/div\u003e\n    \u003c\/div\u003e\n  \u003c\/div\u003e\n\n  \u003cdiv class=\"hvx-desc-card\"\u003e\n    \u003ch2 class=\"hvx-section-title\"\u003eWhat's Included\u003c\/h2\u003e\n    \u003cul style=\"padding-left: 18px; margin: 8px 0;\"\u003e\n      \u003cli\u003eOutdoor unit CH-R28MES-230VO\u003c\/li\u003e\n      \u003cli\u003eOwner \/ installation documentation\u003c\/li\u003e\n    \u003c\/ul\u003e\n    \u003cp class=\"hvx-note\"\u003ePair only with compatible Cooper\u0026amp;Hunter Hyper Multi-Zone indoor units. Confirm zone combinations and piping requirements before installation.\u003c\/p\u003e\n  \u003c\/div\u003e\n\n  \u003cdiv class=\"hvx-desc-card\"\u003e\n    \u003ch2 class=\"hvx-section-title\"\u003eIndoor Specs\u003c\/h2\u003e\n    \u003cdiv class=\"hvx-table-wrap\"\u003e\n      \u003ctable aria-label=\"Indoor unit compatibility\" class=\"hvx-table\"\u003e\n        \u003cthead\u003e\n          \u003ctr\u003e\n\u003cth\u003eSpec\u003c\/th\u003e\n\u003cth\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\n        \u003c\/thead\u003e\n        \u003ctbody\u003e\n          \u003ctr\u003e\n            \u003ctd\u003e\u003cstrong\u003eSystem type\u003c\/strong\u003e\u003c\/td\u003e\n            \u003ctd\u003eMulti-zone unit (outdoor)\u003c\/td\u003e\n          \u003c\/tr\u003e\n          \u003ctr\u003e\n            \u003ctd\u003e\u003cstrong\u003eZones supported\u003c\/strong\u003e\u003c\/td\u003e\n            \u003ctd\u003eUp to 4 independent zones (depends on indoor unit selection)\u003c\/td\u003e\n          \u003c\/tr\u003e\n          \u003ctr\u003e\n            \u003ctd\u003e\u003cstrong\u003eCompatible indoor units\u003c\/strong\u003e\u003c\/td\u003e\n            \u003ctd\u003eCooper\u0026amp;Hunter Hyper Multi-Zone indoor units (zone mix varies by combination)\u003c\/td\u003e\n          \u003c\/tr\u003e\n          \u003ctr\u003e\n            \u003ctd\u003e\u003cstrong\u003eRefrigerant piping (per zone)\u003c\/strong\u003e\u003c\/td\u003e\n            \u003ctd\u003e4 circuits total: 4× 1\/4″ liquid; gas connections are 3× 3\/8″ + 1× 1\/2″\u003c\/td\u003e\n          \u003c\/tr\u003e\n          \u003ctr\u003e\n            \u003ctd\u003e\u003cstrong\u003eMax height difference (IDU↔ODU)\u003c\/strong\u003e\u003c\/td\u003e\n            \u003ctd\u003e49.2 ft\u003c\/td\u003e\n          \u003c\/tr\u003e\n          \u003ctr\u003e\n            \u003ctd\u003e\u003cstrong\u003eCombination guidance\u003c\/strong\u003e\u003c\/td\u003e\n            \u003ctd\u003eUse the provided Multi-Zone Combination PDFs to confirm valid indoor mixes\u003c\/td\u003e\n          \u003c\/tr\u003e\n        \u003c\/tbody\u003e\n      \u003c\/table\u003e\n    \u003c\/div\u003e\n    \u003cp class=\"hvx-note\"\u003eIndoor-unit capacities, features, and controls depend on the specific indoor models selected for each zone.\u003c\/p\u003e\n  \u003c\/div\u003e\n\n  \u003cdiv class=\"hvx-desc-card\"\u003e\n    \u003ch2 class=\"hvx-section-title\"\u003eOutdoor Specs\u003c\/h2\u003e\n    \u003cdiv class=\"hvx-table-wrap\"\u003e\n      \u003ctable aria-label=\"Outdoor unit specifications\" class=\"hvx-table\"\u003e\n        \u003cthead\u003e\n          \u003ctr\u003e\n\u003cth\u003eSpec\u003c\/th\u003e\n\u003cth\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\n        \u003c\/thead\u003e\n        \u003ctbody\u003e\n          \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCH-R28MES-230VO\u003c\/td\u003e\n\u003c\/tr\u003e\n          \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRefrigerant type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eR454B\u003c\/td\u003e\n\u003c\/tr\u003e\n          \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower source\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e208–230V, 1Ph, 60Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n          \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eVoltage range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e187–253 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\n          \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCooling capacity (Min\/Max)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e27,000 BTU\/h (7,200–32,000)\u003c\/td\u003e\n\u003c\/tr\u003e\n          \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eHeating capacity (Min\/Max)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e27,000 BTU\/h (8,400–29,000)\u003c\/td\u003e\n\u003c\/tr\u003e\n\n          \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSEER2 \/ EER2\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e25 \/ 13\u003c\/td\u003e\n\u003c\/tr\u003e\n          \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eHSPF2-4 \/ HSPF2-5\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e9.5 \/ 7.4\u003c\/td\u003e\n\u003c\/tr\u003e\n          \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCOP\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3.8\u003c\/td\u003e\n\u003c\/tr\u003e\n\n          \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMinimum circuit ampacity (MCA)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e23 A\u003c\/td\u003e\n\u003c\/tr\u003e\n          \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMax fuse\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e25 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\n          \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOutdoor Air Flow\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2,130.7 CFM\u003c\/td\u003e\n\u003c\/tr\u003e\n          \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOutdoor Noise Level\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e61 dB(A)\u003c\/td\u003e\n\u003c\/tr\u003e\n          \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDehumidification\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1.69 pints\/day\u003c\/td\u003e\n\u003c\/tr\u003e\n\n          \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eUnit dimensions (W×H×D)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e37.24 × 16.14 × 31.89 in\u003c\/td\u003e\n\u003c\/tr\u003e\n          \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePacking dimensions (W×D×H)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e42.91 × 19.68 × 34.84 in\u003c\/td\u003e\n\u003c\/tr\u003e\n          \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNet \/ Gross weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e138.89 \/ 149.69 lb\u003c\/td\u003e\n\u003c\/tr\u003e\n\n          \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRefrigerant precharge\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e100 (factory charge)\u003c\/td\u003e\n\u003c\/tr\u003e\n          \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRefrigerant piping (Liquid\/Gas)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4× 1\/4″ liquid · (3× 3\/8″ + 1× 1\/2″) gas\u003c\/td\u003e\n\u003c\/tr\u003e\n\n          \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAmbient temperature — Heating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e−13 to 75 °F\u003c\/td\u003e\n\u003c\/tr\u003e\n          \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAmbient temperature — Cooling\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e−13 to 122 °F\u003c\/td\u003e\n\u003c\/tr\u003e\n\n          \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAdditional refrigerant charge — 3\/8″ liquid line\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.32\u003c\/td\u003e\n\u003c\/tr\u003e\n          \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAdditional refrigerant charge — 1\/4″ liquid line\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.16\u003c\/td\u003e\n\u003c\/tr\u003e\n        \u003c\/tbody\u003e\n      \u003c\/table\u003e\n    \u003c\/div\u003e\n  \u003c\/div\u003e\n\n  \u003cdiv class=\"hvx-desc-card\"\u003e\n    \u003ch2 class=\"hvx-section-title\"\u003eDocuments \u0026amp; Downloads\u003c\/h2\u003e\n    \u003cul style=\"padding-left: 18px; margin: 8px 0;\"\u003e\n      \u003cli\u003e\u003ca rel=\"noopener\" href=\"https:\/\/media.cooperandhunter.us\/4445\/CH-R28MES-230VO.pdf\" target=\"_blank\"\u003eCH-R28MES-230VO Submittal (PDF)\u003c\/a\u003e\u003c\/li\u003e\n      \u003cli\u003e\u003ca rel=\"noopener\" href=\"https:\/\/media.cooperandhunter.us\/4446\/CH-R28MES-230VO-non.pdf\" target=\"_blank\"\u003eCH-R28MES-230VO Submittal — Non-Ducted (PDF)\u003c\/a\u003e\u003c\/li\u003e\n      \u003cli\u003e\u003ca rel=\"noopener\" href=\"https:\/\/media.cooperandhunter.us\/4442\/Installation-manual-Multi-R.pdf\" target=\"_blank\"\u003eInstallation Manual — Multi-R (PDF)\u003c\/a\u003e\u003c\/li\u003e\n      \u003cli\u003e\u003ca rel=\"noopener\" href=\"https:\/\/media.cooperandhunter.us\/3198\/MultiZone-Combination-HYPER.pdf\" target=\"_blank\"\u003eMulti-Zone Combination — HYPER (PDF)\u003c\/a\u003e\u003c\/li\u003e\n      \u003cli\u003e\u003ca rel=\"noopener\" href=\"https:\/\/media.cooperandhunter.us\/3199\/MultiZone-Combination-Regular.pdf\" target=\"_blank\"\u003eMulti-Zone Combination — Regular (PDF)\u003c\/a\u003e\u003c\/li\u003e\n    \u003c\/ul\u003e\n    \u003cp class=\"hvx-note\"\u003eAHRI certification numbers (reference): Ducted 215864257 · Non-Ducted 215864258 · Mixed 215864259.\u003c\/p\u003e\n  \u003c\/div\u003e\n\n  \u003cdiv class=\"hvx-desc-card\"\u003e\n    \u003ch2 class=\"hvx-section-title\"\u003eImportant\u003c\/h2\u003e\n    \u003cp style=\"font-size: 14px; color: var(--hvx-slate); margin: 0;\" class=\"hvx-note\"\u003e\n      Install by a licensed HVAC professional. Confirm indoor unit combinations, voltage range (187–253 V), MCA\/max-fuse,\n      refrigerant piping per zone (including the 1\/2″ gas circuit), height limits, and ambient operating ranges before commissioning.\n    \u003c\/p\u003e\n  \u003c\/div\u003e\n\n  \u003cdiv class=\"hvx-desc-card\"\u003e\n    \u003ch2 class=\"hvx-section-title\"\u003eFAQs\u003c\/h2\u003e\n\n    \u003cdetails open class=\"hvx-faq\"\u003e\n      \u003csummary\u003eHow many zones can this support?\u003c\/summary\u003e\n      \u003cdiv style=\"margin-top: 8px;\"\u003eUp to four independent zones with compatible Cooper\u0026amp;Hunter Hyper Multi-Zone indoor units.\u003c\/div\u003e\n    \u003c\/details\u003e\n\n    \u003cdetails open class=\"hvx-faq\"\u003e\n      \u003csummary\u003eWhat line sizes are required?\u003c\/summary\u003e\n      \u003cdiv style=\"margin-top: 8px;\"\u003eFour circuits total: 4× 1\/4″ liquid; gas connections are 3× 3\/8″ plus 1× 1\/2″.\u003c\/div\u003e\n    \u003c\/details\u003e\n\n    \u003cdetails open class=\"hvx-faq\"\u003e\n      \u003csummary\u003eWhat are the power requirements?\u003c\/summary\u003e\n      \u003cdiv style=\"margin-top: 8px;\"\u003e208–230 V, single-phase, 60 Hz. Voltage range 187–253 V. MCA 23 A. Max fuse 25 A.\u003c\/div\u003e\n    \u003c\/details\u003e\n\n    \u003cdetails open class=\"hvx-faq\"\u003e\n      \u003csummary\u003eWhat refrigerant does it use?\u003c\/summary\u003e\n      \u003cdiv style=\"margin-top: 8px;\"\u003eR454B.\u003c\/div\u003e\n    \u003c\/details\u003e\n\n    \u003cdetails open class=\"hvx-faq\"\u003e\n      \u003csummary\u003eWhat are the operating temperature ranges?\u003c\/summary\u003e\n      \u003cdiv style=\"margin-top: 8px;\"\u003eCooling: −13 to 122 °F. Heating: −13 to 75 °F.\u003c\/div\u003e\n    \u003c\/details\u003e\n\n    \u003cdetails open class=\"hvx-faq\"\u003e\n      \u003csummary\u003eHow efficient is this outdoor unit?\u003c\/summary\u003e\n      \u003cdiv style=\"margin-top: 8px;\"\u003eRated up to 25 SEER2 and 13 EER2. HSPF2 is 9.5 (Region IV) \/ 7.4 (Region V).\u003c\/div\u003e\n    \u003c\/details\u003e\n  \u003c\/div\u003e\n\u003c\/div\u003e\n","brand":"Cooper\u0026Hunter","offers":[{"title":"Default Title","offer_id":42697646702635,"sku":"CH-R28MES-230VO","price":2107.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0625\/5647\/1339\/files\/36000BTU_c5d505e7-64c5-4441-ba6b-29b3483de2f2.png?v=1769190457"},{"product_id":"cooper-hunter-multi-zone-r454b-outdoor-condenser-36-000-btu-3-ton","title":"Cooper\u0026Hunter Multi-Zone R454B Outdoor Condenser 36,000 BTU (3 Ton)","description":"\u003cstyle\u003e\n  :root{\n    --hvx-golden:#FAA819;\n    --hvx-slate:#262626;\n    --hvx-ivory:#F4F1E6;\n    --hvx-border:#e2e0d5;\n    --hvx-card-bg:#ffffff;\n  }\n\n  .hvx-desc{\n    font-family:\"Articulat CF\",system-ui,-apple-system,BlinkMacSystemFont,\"Segoe UI\",sans-serif;\n    color:var(--hvx-slate);\n    line-height:1.6;\n    background:var(--hvx-ivory);\n    padding:18px 18px 20px;\n    border-radius:16px;\n  }\n\n  .hvx-desc-header{\n    border-radius:14px;\n    padding:14px 16px;\n    background:linear-gradient(120deg,var(--hvx-golden),var(--hvx-slate));\n    color:#fff;\n    margin:0 0 16px;\n    box-shadow:0 10px 24px rgba(0,0,0,.22);\n    display:flex;\n    align-items:flex-start;\n    gap:12px;\n    flex-wrap:wrap;\n  }\n\n  .hvx-header-text{display:flex;flex-direction:column;gap:4px;min-width:260px}\n  .hvx-eyebrow{\n    font-size:11px;\n    letter-spacing:.14em;\n    text-transform:uppercase;\n    opacity:.9;\n  }\n  .hvx-title{\n    margin:0;\n    font-family:\"Anton\",\"Impact\",system-ui,-apple-system,BlinkMacSystemFont,\"Segoe UI\",sans-serif;\n    font-size:22px;\n    line-height:1.15;\n  }\n\n  .hvx-desc-card{\n    border:1px solid var(--hvx-border);\n    border-radius:14px;\n    background:var(--hvx-card-bg);\n    padding:16px 18px 18px;\n    box-shadow:0 4px 12px rgba(0,0,0,.06);\n    margin:14px 0;\n  }\n\n  .hvx-section-title{\n    margin:0 0 10px;\n    font-family:\"Anton\",\"Impact\",system-ui,-apple-system,BlinkMacSystemFont,\"Segoe UI\",sans-serif;\n    font-size:17px;\n    letter-spacing:.08em;\n    text-transform:uppercase;\n    color:var(--hvx-slate);\n    display:inline-flex;\n    align-items:center;\n    gap:8px;\n  }\n  .hvx-section-title::after{\n    content:\"\";\n    flex:1;\n    height:2px;\n    border-radius:999px;\n    background:linear-gradient(90deg,var(--hvx-golden),transparent);\n    opacity:.9;\n  }\n\n  .hvx-cta{display:flex;flex-wrap:wrap;gap:10px;margin:10px 0 0}\n  .hvx-cta a{\n    display:inline-flex;\n    align-items:center;\n    gap:8px;\n    padding:10px 14px;\n    border-radius:12px;\n    border:1px solid var(--hvx-border);\n    background:#fff;\n    text-decoration:none;\n    color:var(--hvx-slate);\n    font-size:14px;\n    font-weight:700;\n  }\n  .hvx-cta a.primary{\n    background:var(--hvx-slate);\n    color:#fff;\n    border-color:transparent;\n  }\n\n  .hvx-badges{display:flex;flex-wrap:wrap;gap:8px;margin:10px 0 0}\n  .hvx-badge{\n    font-size:12px;\n    border:1px solid var(--hvx-border);\n    border-radius:999px;\n    padding:6px 10px;\n    background:#fff;\n    white-space:nowrap;\n  }\n\n  .hvx-kv{\n    display:grid;\n    grid-template-columns:repeat(4,minmax(160px,1fr));\n    gap:10px;\n    margin-top:10px;\n  }\n  .hvx-kv \u003e div{\n    border:1px solid var(--hvx-border);\n    background:#fff;\n    border-radius:12px;\n    padding:10px 12px;\n    text-align:center;\n  }\n  .hvx-kv strong{display:block}\n\n  .hvx-table{\n    width:100%;\n    border-collapse:collapse;\n    min-width:520px;\n    background:#fff;\n    border:1px solid var(--hvx-border);\n    border-radius:12px;\n    overflow:hidden;\n  }\n  .hvx-table th,.hvx-table td{\n    border-bottom:1px solid var(--hvx-border);\n    padding:10px 12px;\n    vertical-align:top;\n    font-size:14px;\n  }\n  .hvx-table th{ text-align:left; font-weight:800; background:#fff; }\n  .hvx-table tr:nth-child(odd) td{ background:#fff; }\n  .hvx-table tr:nth-child(even) td{ background:#fbfaf6; }\n  .hvx-table tr:last-child td{ border-bottom:none; }\n  .hvx-table-wrap{ overflow:auto; border-radius:12px; }\n\n  .hvx-note{\n    font-size:12px;\n    color:#555;\n    margin:10px 0 0;\n  }\n\n  details.hvx-faq{\n    border:1px solid var(--hvx-border);\n    background:#fff;\n    border-radius:12px;\n    padding:10px 12px;\n    margin:8px 0;\n  }\n  details.hvx-faq summary{\n    cursor:pointer;\n    font-weight:800;\n  }\n\n  @media(max-width:980px){\n    .hvx-kv{grid-template-columns:repeat(2,minmax(160px,1fr))}\n  }\n  @media(max-width:768px){\n    .hvx-desc{padding:14px 12px 16px;border-radius:12px}\n    .hvx-desc-header{padding:12px;border-radius:12px}\n    .hvx-title{font-size:19px}\n    .hvx-desc-card{padding:14px;margin:10px 0}\n  }\n\u003c\/style\u003e\n\u003cdiv class=\"hvx-desc\"\u003e\n\u003cdiv class=\"hvx-desc-header\"\u003e\n\u003cdiv class=\"hvx-header-text\"\u003e\n\u003cdiv class=\"hvx-eyebrow\"\u003eCooper\u0026amp;Hunter Hyper Multi-Zone Outdoor • R454B • Multi-Zone\u003c\/div\u003e\n\u003ch1 class=\"hvx-title\"\u003eCooper\u0026amp;Hunter Hyper Multi-Zone Outdoor — 36,000 BTU, R454B — CH-R36MES-230VO\u003c\/h1\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv aria-label=\"Contact options\" class=\"hvx-cta\"\u003e\n\u003ca title=\"Contact Us\" rel=\"noopener\" href=\"https:\/\/hvacsupplies.com\/pages\/contact\" class=\"primary\" target=\"_blank\"\u003e CLICK HERE TO CONTACT US FOR CUSTOM QUOTES AND QUESTIONS \u003c\/a\u003e \u003ca title=\"Call Us Now!\" href=\"tel:+18005438933\"\u003e CLICK TO CALL US 1-800-543-8933 FOR ANY QUESTIONS \u003c\/a\u003e \u003cbr\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"hvx-desc-card\"\u003e\n\u003ch2 class=\"hvx-section-title\"\u003eOverview\u003c\/h2\u003e\n\u003cp style=\"margin: 0;\"\u003eCooper\u0026amp;Hunter’s 36K BTU Hyper Multi-Zone outdoor unit is a powerful, adaptable solution for large residential applications. Supporting up to five zones, it delivers individualized temperature control across multiple rooms. State-of-the-art inverter technology dynamically modulates compressor output to match demand for steady comfort and optimized energy use. With up to 24 SEER2 efficiency and R454B refrigerant (lower GWP vs. many conventional options), it’s designed for modern, eco-conscious multi-zone installations.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"hvx-desc-card\"\u003e\n\u003ch2 class=\"hvx-section-title\"\u003eHighlights\u003c\/h2\u003e\n\u003cdiv role=\"list\" class=\"hvx-badges\"\u003e\n\u003cspan role=\"listitem\" class=\"hvx-badge\"\u003e36,000 BTU cool (9,000–42,000)\u003c\/span\u003e \u003cspan role=\"listitem\" class=\"hvx-badge\"\u003e37,000 BTU heat (10,000–42,500)\u003c\/span\u003e \u003cspan role=\"listitem\" class=\"hvx-badge\"\u003eUp to 5 zones\u003c\/span\u003e \u003cspan role=\"listitem\" class=\"hvx-badge\"\u003eSEER2 24 · EER2 12\u003c\/span\u003e \u003cspan role=\"listitem\" class=\"hvx-badge\"\u003eHSPF2 9.5 (Region IV) · 7.4 (Region V)\u003c\/span\u003e \u003cspan role=\"listitem\" class=\"hvx-badge\"\u003eCOP 3.5\u003c\/span\u003e \u003cspan role=\"listitem\" class=\"hvx-badge\"\u003eR454B\u003c\/span\u003e \u003cspan role=\"listitem\" class=\"hvx-badge\"\u003e208–230V 1Ph\u003c\/span\u003e \u003cspan role=\"listitem\" class=\"hvx-badge\"\u003e−13–122 °F cool · −13–75 °F heat\u003c\/span\u003e\n\u003c\/div\u003e\n\u003cul style=\"margin: 12px 0 0; padding-left: 18px;\"\u003e\n\u003cli\u003e\n\u003cstrong\u003eMulti-zone flexibility:\u003c\/strong\u003e supports up to 5 independent zones with compatible indoor units.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHigh efficiency:\u003c\/strong\u003e up to 24 SEER2 for strong seasonal energy savings.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInverter performance:\u003c\/strong\u003e dynamic compressor modulation for stable comfort and reduced operating cost.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEco-forward refrigerant:\u003c\/strong\u003e uses R454B to reduce environmental impact.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBuilt for larger homes:\u003c\/strong\u003e higher capacity and multi-room control for bigger layouts.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cdiv aria-label=\"At-a-glance\" role=\"list\" class=\"hvx-kv\"\u003e\n\u003cdiv role=\"listitem\"\u003e\n\u003cstrong\u003eModel\u003c\/strong\u003eCH-R36MES-230VO\u003c\/div\u003e\n\u003cdiv role=\"listitem\"\u003e\n\u003cstrong\u003eZones\u003c\/strong\u003eUp to 5\u003c\/div\u003e\n\u003cdiv role=\"listitem\"\u003e\n\u003cstrong\u003eOutdoor Sound\u003c\/strong\u003e64.5 dB(A)\u003c\/div\u003e\n\u003cdiv role=\"listitem\"\u003e\n\u003cstrong\u003eLines\u003c\/strong\u003e5× 1\/4″ liquid · (4× 3\/8″ + 1× 1\/2″) gas\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"hvx-desc-card\"\u003e\n\u003ch2 class=\"hvx-section-title\"\u003eWhat's Included\u003c\/h2\u003e\n\u003cul style=\"padding-left: 18px; margin: 8px 0;\"\u003e\n\u003cli\u003eOutdoor unit CH-R36MES-230VO\u003c\/li\u003e\n\u003cli\u003eOwner \/ installation documentation\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp class=\"hvx-note\"\u003ePair only with compatible Cooper\u0026amp;Hunter Hyper Multi-Zone indoor units. Confirm zone combinations and piping requirements before installation.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"hvx-desc-card\"\u003e\n\u003ch2 class=\"hvx-section-title\"\u003eIndoor Specs\u003c\/h2\u003e\n\u003cdiv class=\"hvx-table-wrap\"\u003e\n\u003ctable aria-label=\"Indoor unit compatibility\" class=\"hvx-table\" style=\"width: 101.881%; height: 268.8px;\"\u003e\n\u003cthead\u003e\n\u003ctr style=\"height: 22.4px;\"\u003e\n\u003cth style=\"width: 30.81%; height: 22.4px;\"\u003eSpec\u003c\/th\u003e\n\u003cth style=\"width: 59.4977%; height: 22.4px;\"\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr style=\"height: 22.4px;\"\u003e\n\u003ctd style=\"width: 30.81%; height: 22.4px;\"\u003e\u003cstrong\u003eSystem type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 59.4977%; height: 22.4px;\"\u003eMulti-zone unit (outdoor)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 44.8px;\"\u003e\n\u003ctd style=\"width: 30.81%; height: 44.8px;\"\u003e\u003cstrong\u003eZones supported\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 59.4977%; height: 44.8px;\"\u003eUp to 5 independent zones (depends on indoor unit selection)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 44.8px;\"\u003e\n\u003ctd style=\"width: 30.81%; height: 44.8px;\"\u003e\u003cstrong\u003eCompatible indoor units\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 59.4977%; height: 44.8px;\"\u003eCooper\u0026amp;Hunter Hyper Multi-Zone indoor units (zone mix varies by combination)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 44.8px;\"\u003e\n\u003ctd style=\"width: 30.81%; height: 44.8px;\"\u003e\u003cstrong\u003eRefrigerant piping (per zone)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 59.4977%; height: 44.8px;\"\u003e5 circuits total: 5× 1\/4″ liquid; gas connections are 4× 3\/8″ + 1× 1\/2″\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 44.8px;\"\u003e\n\u003ctd style=\"width: 30.81%; height: 44.8px;\"\u003e\u003cstrong\u003eMax height difference (IDU↔ODU)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 59.4977%; height: 44.8px;\"\u003e49.2 ft\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 44.8px;\"\u003e\n\u003ctd style=\"width: 30.81%; height: 44.8px;\"\u003e\u003cstrong\u003eCombination guidance\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 59.4977%; height: 44.8px;\"\u003eUse the provided Multi-Zone Combination PDFs to confirm valid indoor mixes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003cp class=\"hvx-note\"\u003eIndoor-unit capacities, features, and controls depend on the specific indoor models selected for each zone.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"hvx-desc-card\"\u003e\n\u003ch2 class=\"hvx-section-title\"\u003eOutdoor Specs\u003c\/h2\u003e\n\u003cdiv class=\"hvx-table-wrap\"\u003e\n\u003ctable aria-label=\"Outdoor unit specifications\" class=\"hvx-table\"\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eSpec\u003c\/th\u003e\n\u003cth\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCH-R36MES-230VO\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRefrigerant type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eR454B\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower source\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e208–230V, 1Ph, 60Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eVoltage range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e187–253 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCooling capacity (Min\/Max)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e36,000 BTU\/h (9,000–42,000)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eHeating capacity (Min\/Max)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e37,000 BTU\/h (10,000–42,500)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSEER2 \/ EER2\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e24 \/ 12\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eHSPF2-4 \/ HSPF2-5\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e9.5 \/ 7.4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCOP\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3.5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMinimum circuit ampacity (MCA)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e30.5 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMax fuse\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e35 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOutdoor Air Flow\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2,148.4 CFM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOutdoor Noise Level\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e64.5 dB(A)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDehumidification\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2.11 pints\/day\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eUnit dimensions (W×H×D)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e37.24 × 16.14 × 31.89 in\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePacking dimensions (W×D×H)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e42.91 × 19.68 × 34.84 in\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNet \/ Gross weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e168.87 \/ 180.12 lb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRefrigerant precharge\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e125 (factory charge)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRefrigerant piping (Liquid\/Gas)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e5× 1\/4″ liquid · (4× 3\/8″ + 1× 1\/2″) gas\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAmbient temperature — Heating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e−13 to 75 °F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAmbient temperature — Cooling\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e−13 to 122 °F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAdditional refrigerant charge — 3\/8″ liquid line\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.32\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAdditional refrigerant charge — 1\/4″ liquid line\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.16\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"hvx-desc-card\"\u003e\n\u003ch2 class=\"hvx-section-title\"\u003eDocuments \u0026amp; Downloads\u003c\/h2\u003e\n\u003cul style=\"padding-left: 18px; margin: 8px 0;\"\u003e\n\u003cli\u003e\u003ca rel=\"noopener\" href=\"https:\/\/media.cooperandhunter.us\/4447\/CH-R36MES-230VO.pdf\" target=\"_blank\"\u003eCH-R36MES-230VO Submittal (PDF)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca rel=\"noopener\" href=\"https:\/\/media.cooperandhunter.us\/4448\/CH-R36MES-230VO_Non-ducted.pdf\" target=\"_blank\"\u003eCH-R36MES-230VO Submittal — Non-Ducted (PDF)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca rel=\"noopener\" href=\"https:\/\/media.cooperandhunter.us\/4442\/Installation-manual-Multi-R.pdf\" target=\"_blank\"\u003eInstallation Manual — Multi-R (PDF)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca rel=\"noopener\" href=\"https:\/\/media.cooperandhunter.us\/3198\/MultiZone-Combination-HYPER.pdf\" target=\"_blank\"\u003eMulti-Zone Combination — HYPER (PDF)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca rel=\"noopener\" href=\"https:\/\/media.cooperandhunter.us\/3199\/MultiZone-Combination-Regular.pdf\" target=\"_blank\"\u003eMulti-Zone Combination — Regular (PDF)\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp class=\"hvx-note\"\u003eAHRI certification numbers (reference): Ducted 215864260 · Non-Ducted 215864261 · Mixed 215864262.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"hvx-desc-card\"\u003e\n\u003ch2 class=\"hvx-section-title\"\u003eImportant\u003c\/h2\u003e\n\u003cp style=\"font-size: 14px; color: var(--hvx-slate); margin: 0;\" class=\"hvx-note\"\u003eInstall by a licensed HVAC professional. Confirm indoor unit combinations, voltage range (187–253 V), MCA\/max-fuse, refrigerant piping per zone (including the 1\/2″ gas circuit), height limits, and ambient operating ranges before commissioning.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"hvx-desc-card\"\u003e\n\u003ch2 class=\"hvx-section-title\"\u003eFAQs\u003c\/h2\u003e\n\u003cdetails open=\"\" class=\"hvx-faq\"\u003e\n\u003csummary\u003eHow many zones can this support?\u003c\/summary\u003e\n\u003cdiv style=\"margin-top: 8px;\"\u003eUp to five independent zones with compatible Cooper\u0026amp;Hunter Hyper Multi-Zone indoor units.\u003c\/div\u003e\n\u003c\/details\u003e\n\u003cdetails open=\"\" class=\"hvx-faq\"\u003e\n\u003csummary\u003eWhat line sizes are required?\u003c\/summary\u003e\n\u003cdiv style=\"margin-top: 8px;\"\u003eFive circuits total: 5× 1\/4″ liquid; gas connections are 4× 3\/8″ plus 1× 1\/2″.\u003c\/div\u003e\n\u003c\/details\u003e\n\u003cdetails open=\"\" class=\"hvx-faq\"\u003e\n\u003csummary\u003eWhat are the power requirements?\u003c\/summary\u003e\n\u003cdiv style=\"margin-top: 8px;\"\u003e208–230 V, single-phase, 60 Hz. Voltage range 187–253 V. MCA 30.5 A. Max fuse 35 A.\u003c\/div\u003e\n\u003c\/details\u003e\n\u003cdetails open=\"\" class=\"hvx-faq\"\u003e\n\u003csummary\u003eWhat refrigerant does it use?\u003c\/summary\u003e\n\u003cdiv style=\"margin-top: 8px;\"\u003eR454B.\u003c\/div\u003e\n\u003c\/details\u003e\n\u003cdetails open=\"\" class=\"hvx-faq\"\u003e\n\u003csummary\u003eWhat are the operating temperature ranges?\u003c\/summary\u003e\n\u003cdiv style=\"margin-top: 8px;\"\u003eCooling: −13 to 122 °F. Heating: −13 to 75 °F.\u003c\/div\u003e\n\u003c\/details\u003e\n\u003cdetails open=\"\" class=\"hvx-faq\"\u003e\n\u003csummary\u003eHow efficient is this outdoor unit?\u003c\/summary\u003e\n\u003cdiv style=\"margin-top: 8px;\"\u003eRated up to 24 SEER2 and 12 EER2. HSPF2 is 9.5 (Region IV) \/ 7.4 (Region V).\u003c\/div\u003e\n\u003c\/details\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e","brand":"Cooper\u0026Hunter","offers":[{"title":"Default Title","offer_id":42697653780523,"sku":"CH-R36MES-230VO","price":3141.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0625\/5647\/1339\/files\/36000BTU_c5d505e7-64c5-4441-ba6b-29b3483de2f2.png?v=1769190457"},{"product_id":"cooper-hunter-multi-zone-r454b-outdoor-condenser-48-000-btu-4-ton","title":"Cooper\u0026Hunter Multi-Zone R454B Outdoor Condenser 48,000 BTU (4 Ton)","description":"\u003cstyle\u003e\n  :root{\n    --hvx-golden:#FAA819;\n    --hvx-slate:#262626;\n    --hvx-ivory:#F4F1E6;\n    --hvx-border:#e2e0d5;\n    --hvx-card-bg:#ffffff;\n  }\n\n  .hvx-desc{\n    font-family:\"Articulat CF\",system-ui,-apple-system,BlinkMacSystemFont,\"Segoe UI\",sans-serif;\n    color:var(--hvx-slate);\n    line-height:1.6;\n    background:var(--hvx-ivory);\n    padding:18px 18px 20px;\n    border-radius:16px;\n  }\n\n  .hvx-desc-header{\n    border-radius:14px;\n    padding:14px 16px;\n    background:linear-gradient(120deg,var(--hvx-golden),var(--hvx-slate));\n    color:#fff;\n    margin:0 0 16px;\n    box-shadow:0 10px 24px rgba(0,0,0,.22);\n    display:flex;\n    align-items:flex-start;\n    gap:12px;\n    flex-wrap:wrap;\n  }\n\n  .hvx-header-text{display:flex;flex-direction:column;gap:4px;min-width:260px}\n  .hvx-eyebrow{\n    font-size:11px;\n    letter-spacing:.14em;\n    text-transform:uppercase;\n    opacity:.9;\n  }\n  .hvx-title{\n    margin:0;\n    font-family:\"Anton\",\"Impact\",system-ui,-apple-system,BlinkMacSystemFont,\"Segoe UI\",sans-serif;\n    font-size:22px;\n    line-height:1.15;\n  }\n\n  .hvx-desc-card{\n    border:1px solid var(--hvx-border);\n    border-radius:14px;\n    background:var(--hvx-card-bg);\n    padding:16px 18px 18px;\n    box-shadow:0 4px 12px rgba(0,0,0,.06);\n    margin:14px 0;\n  }\n\n  .hvx-section-title{\n    margin:0 0 10px;\n    font-family:\"Anton\",\"Impact\",system-ui,-apple-system,BlinkMacSystemFont,\"Segoe UI\",sans-serif;\n    font-size:17px;\n    letter-spacing:.08em;\n    text-transform:uppercase;\n    color:var(--hvx-slate);\n    display:inline-flex;\n    align-items:center;\n    gap:8px;\n  }\n  .hvx-section-title::after{\n    content:\"\";\n    flex:1;\n    height:2px;\n    border-radius:999px;\n    background:linear-gradient(90deg,var(--hvx-golden),transparent);\n    opacity:.9;\n  }\n\n  .hvx-cta{display:flex;flex-wrap:wrap;gap:10px;margin:10px 0 0}\n  .hvx-cta a{\n    display:inline-flex;\n    align-items:center;\n    gap:8px;\n    padding:10px 14px;\n    border-radius:12px;\n    border:1px solid var(--hvx-border);\n    background:#fff;\n    text-decoration:none;\n    color:var(--hvx-slate);\n    font-size:14px;\n    font-weight:700;\n  }\n  .hvx-cta a.primary{\n    background:var(--hvx-slate);\n    color:#fff;\n    border-color:transparent;\n  }\n\n  .hvx-badges{display:flex;flex-wrap:wrap;gap:8px;margin:10px 0 0}\n  .hvx-badge{\n    font-size:12px;\n    border:1px solid var(--hvx-border);\n    border-radius:999px;\n    padding:6px 10px;\n    background:#fff;\n    white-space:nowrap;\n  }\n\n  .hvx-kv{\n    display:grid;\n    grid-template-columns:repeat(4,minmax(160px,1fr));\n    gap:10px;\n    margin-top:10px;\n  }\n  .hvx-kv \u003e div{\n    border:1px solid var(--hvx-border);\n    background:#fff;\n    border-radius:12px;\n    padding:10px 12px;\n    text-align:center;\n  }\n  .hvx-kv strong{display:block}\n\n  .hvx-table{\n    width:100%;\n    border-collapse:collapse;\n    min-width:520px;\n    background:#fff;\n    border:1px solid var(--hvx-border);\n    border-radius:12px;\n    overflow:hidden;\n  }\n  .hvx-table th,.hvx-table td{\n    border-bottom:1px solid var(--hvx-border);\n    padding:10px 12px;\n    vertical-align:top;\n    font-size:14px;\n  }\n  .hvx-table th{ text-align:left; font-weight:800; background:#fff; }\n  .hvx-table tr:nth-child(odd) td{ background:#fff; }\n  .hvx-table tr:nth-child(even) td{ background:#fbfaf6; }\n  .hvx-table tr:last-child td{ border-bottom:none; }\n  .hvx-table-wrap{ overflow:auto; border-radius:12px; }\n\n  .hvx-note{\n    font-size:12px;\n    color:#555;\n    margin:10px 0 0;\n  }\n\n  details.hvx-faq{\n    border:1px solid var(--hvx-border);\n    background:#fff;\n    border-radius:12px;\n    padding:10px 12px;\n    margin:8px 0;\n  }\n  details.hvx-faq summary{\n    cursor:pointer;\n    font-weight:800;\n  }\n\n  @media(max-width:980px){\n    .hvx-kv{grid-template-columns:repeat(2,minmax(160px,1fr))}\n  }\n  @media(max-width:768px){\n    .hvx-desc{padding:14px 12px 16px;border-radius:12px}\n    .hvx-desc-header{padding:12px;border-radius:12px}\n    .hvx-title{font-size:19px}\n    .hvx-desc-card{padding:14px;margin:10px 0}\n  }\n\u003c\/style\u003e\n\n\u003cdiv class=\"hvx-desc\"\u003e\n  \u003cdiv class=\"hvx-desc-header\"\u003e\n    \u003cdiv class=\"hvx-header-text\"\u003e\n      \u003cdiv class=\"hvx-eyebrow\"\u003eCooper\u0026amp;Hunter Hyper Multi-Zone Outdoor • R454B • Multi-Zone\u003c\/div\u003e\n      \u003ch1 class=\"hvx-title\"\u003eCooper\u0026amp;Hunter Hyper Multi-Zone Outdoor — 48,000 BTU, R454B — CH-R48MES-230VO\u003c\/h1\u003e\n    \u003c\/div\u003e\n  \u003c\/div\u003e\n\n  \u003cdiv aria-label=\"Contact options\" class=\"hvx-cta\"\u003e\n    \u003ca title=\"Contact Us\" rel=\"noopener\" href=\"https:\/\/hvacsupplies.com\/pages\/contact\" class=\"primary\" target=\"_blank\"\u003e\n      CLICK HERE TO CONTACT US FOR CUSTOM QUOTES AND QUESTIONS\n    \u003c\/a\u003e\n    \u003ca title=\"Call Us Now!\" href=\"tel:+18005438933\"\u003e\n      CLICK TO CALL US 1-800-543-8933 FOR ANY QUESTIONS\n    \u003c\/a\u003e\n    \u003cbr\u003e\n  \u003c\/div\u003e\n\n  \u003cdiv class=\"hvx-desc-card\"\u003e\n    \u003ch2 class=\"hvx-section-title\"\u003eOverview\u003c\/h2\u003e\n    \u003cp style=\"margin:0;\"\u003e\n      Cooper\u0026amp;Hunter’s 48K BTU Hyper Multi-Zone outdoor unit is a state-of-the-art solution for customized climate\n      control across large residential and light commercial spaces. Supporting up to six zones, it enables independent\n      temperature regulation in multiple rooms. Advanced inverter technology modulates compressor speed to match load\n      demand, helping reduce energy consumption while maintaining strong performance. With up to 24 SEER2 efficiency and\n      R454B refrigerant (lower GWP vs. many conventional options), it’s designed for modern, eco-conscious multi-zone\n      installations built for year-round comfort.\n    \u003c\/p\u003e\n  \u003c\/div\u003e\n\n  \u003cdiv class=\"hvx-desc-card\"\u003e\n    \u003ch2 class=\"hvx-section-title\"\u003eHighlights\u003c\/h2\u003e\n\n    \u003cdiv role=\"list\" class=\"hvx-badges\"\u003e\n      \u003cspan role=\"listitem\" class=\"hvx-badge\"\u003e47,000 BTU cool (12,000–55,000)\u003c\/span\u003e\n      \u003cspan role=\"listitem\" class=\"hvx-badge\"\u003e48,000 BTU heat (13,000–53,000)\u003c\/span\u003e\n      \u003cspan role=\"listitem\" class=\"hvx-badge\"\u003eUp to 6 zones\u003c\/span\u003e\n      \u003cspan role=\"listitem\" class=\"hvx-badge\"\u003eSEER2 24 · EER2 12.5\u003c\/span\u003e\n      \u003cspan role=\"listitem\" class=\"hvx-badge\"\u003eHSPF2 10.3 (Region IV) · 8.0 (Region V)\u003c\/span\u003e\n      \u003cspan role=\"listitem\" class=\"hvx-badge\"\u003eCOP 3.8\u003c\/span\u003e\n      \u003cspan role=\"listitem\" class=\"hvx-badge\"\u003eR454B\u003c\/span\u003e\n      \u003cspan role=\"listitem\" class=\"hvx-badge\"\u003e208–230V 1Ph\u003c\/span\u003e\n      \u003cspan role=\"listitem\" class=\"hvx-badge\"\u003e−13–122 °F cool · −13–75 °F heat\u003c\/span\u003e\n    \u003c\/div\u003e\n\n    \u003cul style=\"margin: 12px 0 0; padding-left: 18px;\"\u003e\n      \u003cli\u003e\n\u003cstrong\u003eMulti-zone flexibility:\u003c\/strong\u003e supports up to 6 independent zones with compatible indoor units.\u003c\/li\u003e\n      \u003cli\u003e\n\u003cstrong\u003eHigh efficiency:\u003c\/strong\u003e up to 24 SEER2 for strong seasonal energy savings.\u003c\/li\u003e\n      \u003cli\u003e\n\u003cstrong\u003eInverter performance:\u003c\/strong\u003e variable compressor output helps maintain steady comfort under changing loads.\u003c\/li\u003e\n      \u003cli\u003e\n\u003cstrong\u003eEco-forward refrigerant:\u003c\/strong\u003e uses R454B to reduce environmental impact.\u003c\/li\u003e\n      \u003cli\u003e\n\u003cstrong\u003eBuilt for bigger applications:\u003c\/strong\u003e excellent fit for larger homes and light commercial layouts.\u003c\/li\u003e\n    \u003c\/ul\u003e\n\n    \u003cdiv aria-label=\"At-a-glance\" role=\"list\" class=\"hvx-kv\"\u003e\n      \u003cdiv role=\"listitem\"\u003e\n\u003cstrong\u003eModel\u003c\/strong\u003eCH-R48MES-230VO\u003c\/div\u003e\n      \u003cdiv role=\"listitem\"\u003e\n\u003cstrong\u003eZones\u003c\/strong\u003eUp to 6\u003c\/div\u003e\n      \u003cdiv role=\"listitem\"\u003e\n\u003cstrong\u003eOutdoor Sound\u003c\/strong\u003e63 dB(A)\u003c\/div\u003e\n      \u003cdiv role=\"listitem\"\u003e\n\u003cstrong\u003eLines\u003c\/strong\u003e6× 1\/4″ liquid · (4× 3\/8″ + 2× 1\/2″) gas\u003c\/div\u003e\n    \u003c\/div\u003e\n  \u003c\/div\u003e\n\n  \u003cdiv class=\"hvx-desc-card\"\u003e\n    \u003ch2 class=\"hvx-section-title\"\u003eWhat's Included\u003c\/h2\u003e\n    \u003cul style=\"padding-left: 18px; margin: 8px 0;\"\u003e\n      \u003cli\u003eOutdoor unit CH-R48MES-230VO\u003c\/li\u003e\n      \u003cli\u003eOwner \/ installation documentation\u003c\/li\u003e\n    \u003c\/ul\u003e\n    \u003cp class=\"hvx-note\"\u003ePair only with compatible Cooper\u0026amp;Hunter Hyper Multi-Zone indoor units. Confirm zone combinations and piping requirements before installation.\u003c\/p\u003e\n  \u003c\/div\u003e\n\n  \u003cdiv class=\"hvx-desc-card\"\u003e\n    \u003ch2 class=\"hvx-section-title\"\u003eIndoor Specs\u003c\/h2\u003e\n    \u003cdiv class=\"hvx-table-wrap\"\u003e\n      \u003ctable aria-label=\"Indoor unit compatibility\" class=\"hvx-table\"\u003e\n        \u003cthead\u003e\n          \u003ctr\u003e\n\u003cth\u003eSpec\u003c\/th\u003e\n\u003cth\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\n        \u003c\/thead\u003e\n        \u003ctbody\u003e\n          \u003ctr\u003e\n            \u003ctd\u003e\u003cstrong\u003eSystem type\u003c\/strong\u003e\u003c\/td\u003e\n            \u003ctd\u003eMulti-zone unit (outdoor)\u003c\/td\u003e\n          \u003c\/tr\u003e\n          \u003ctr\u003e\n            \u003ctd\u003e\u003cstrong\u003eZones supported\u003c\/strong\u003e\u003c\/td\u003e\n            \u003ctd\u003eUp to 6 independent zones (depends on indoor unit selection)\u003c\/td\u003e\n          \u003c\/tr\u003e\n          \u003ctr\u003e\n            \u003ctd\u003e\u003cstrong\u003eCompatible indoor units\u003c\/strong\u003e\u003c\/td\u003e\n            \u003ctd\u003eCooper\u0026amp;Hunter Hyper Multi-Zone indoor units (zone mix varies by combination)\u003c\/td\u003e\n          \u003c\/tr\u003e\n          \u003ctr\u003e\n            \u003ctd\u003e\u003cstrong\u003eRefrigerant piping (per zone)\u003c\/strong\u003e\u003c\/td\u003e\n            \u003ctd\u003e6 circuits total: 6× 1\/4″ liquid; gas connections are 4× 3\/8″ + 2× 1\/2″\u003c\/td\u003e\n          \u003c\/tr\u003e\n          \u003ctr\u003e\n            \u003ctd\u003e\u003cstrong\u003eMax height difference (IDU↔ODU)\u003c\/strong\u003e\u003c\/td\u003e\n            \u003ctd\u003e49.2 ft\u003c\/td\u003e\n          \u003c\/tr\u003e\n          \u003ctr\u003e\n            \u003ctd\u003e\u003cstrong\u003eCombination guidance\u003c\/strong\u003e\u003c\/td\u003e\n            \u003ctd\u003eUse the provided Multi-Zone Combination PDFs to confirm valid indoor mixes\u003c\/td\u003e\n          \u003c\/tr\u003e\n        \u003c\/tbody\u003e\n      \u003c\/table\u003e\n    \u003c\/div\u003e\n    \u003cp class=\"hvx-note\"\u003eIndoor-unit capacities, features, and controls depend on the specific indoor models selected for each zone.\u003c\/p\u003e\n  \u003c\/div\u003e\n\n  \u003cdiv class=\"hvx-desc-card\"\u003e\n    \u003ch2 class=\"hvx-section-title\"\u003eOutdoor Specs\u003c\/h2\u003e\n    \u003cdiv class=\"hvx-table-wrap\"\u003e\n      \u003ctable aria-label=\"Outdoor unit specifications\" class=\"hvx-table\"\u003e\n        \u003cthead\u003e\n          \u003ctr\u003e\n\u003cth\u003eSpec\u003c\/th\u003e\n\u003cth\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\n        \u003c\/thead\u003e\n        \u003ctbody\u003e\n          \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCH-R48MES-230VO\u003c\/td\u003e\n\u003c\/tr\u003e\n          \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRefrigerant type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eR454B\u003c\/td\u003e\n\u003c\/tr\u003e\n          \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower source\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e208–230V, 1Ph, 60Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n          \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eVoltage range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e187–253 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\n          \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCooling capacity (Min\/Max)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e47,000 BTU\/h (12,000–55,000)\u003c\/td\u003e\n\u003c\/tr\u003e\n          \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eHeating capacity (Min\/Max)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e48,000 BTU\/h (13,000–53,000)\u003c\/td\u003e\n\u003c\/tr\u003e\n\n          \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSEER2 \/ EER2\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e24 \/ 12.5\u003c\/td\u003e\n\u003c\/tr\u003e\n          \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eHSPF2-4 \/ HSPF2-5\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e10.3 \/ 8.0\u003c\/td\u003e\n\u003c\/tr\u003e\n          \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCOP\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3.8\u003c\/td\u003e\n\u003c\/tr\u003e\n\n          \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMinimum circuit ampacity (MCA)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e34 A\u003c\/td\u003e\n\u003c\/tr\u003e\n          \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMax fuse\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e40 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\n          \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOutdoor Air Flow\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4,502.8 CFM\u003c\/td\u003e\n\u003c\/tr\u003e\n          \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOutdoor Noise Level\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e63 dB(A)\u003c\/td\u003e\n\u003c\/tr\u003e\n          \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDehumidification\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e6.98 pints\/day\u003c\/td\u003e\n\u003c\/tr\u003e\n\n          \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eUnit dimensions (W×H×D)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e37.48 × 16.34 × 52.48 in\u003c\/td\u003e\n\u003c\/tr\u003e\n          \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePacking dimensions (W×D×H)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e43.11 × 19.49 × 58.27 in\u003c\/td\u003e\n\u003c\/tr\u003e\n          \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNet \/ Gross weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e222.00 \/ 254.19 lb\u003c\/td\u003e\n\u003c\/tr\u003e\n\n          \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRefrigerant precharge\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e150 (factory charge)\u003c\/td\u003e\n\u003c\/tr\u003e\n          \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRefrigerant piping (Liquid\/Gas)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e6× 1\/4″ liquid · (4× 3\/8″ + 2× 1\/2″) gas\u003c\/td\u003e\n\u003c\/tr\u003e\n\n          \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAmbient temperature — Heating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e−13 to 75 °F\u003c\/td\u003e\n\u003c\/tr\u003e\n          \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAmbient temperature — Cooling\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e−13 to 122 °F\u003c\/td\u003e\n\u003c\/tr\u003e\n\n          \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAdditional refrigerant charge — 3\/8″ liquid line\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.32\u003c\/td\u003e\n\u003c\/tr\u003e\n          \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAdditional refrigerant charge — 1\/4″ liquid line\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.16\u003c\/td\u003e\n\u003c\/tr\u003e\n        \u003c\/tbody\u003e\n      \u003c\/table\u003e\n    \u003c\/div\u003e\n  \u003c\/div\u003e\n\n  \u003cdiv class=\"hvx-desc-card\"\u003e\n    \u003ch2 class=\"hvx-section-title\"\u003eDocuments \u0026amp; Downloads\u003c\/h2\u003e\n    \u003cul style=\"padding-left: 18px; margin: 8px 0;\"\u003e\n      \u003cli\u003e\u003ca rel=\"noopener\" href=\"https:\/\/media.cooperandhunter.us\/4449\/CH-R48MES-230VO.pdf\" target=\"_blank\"\u003eCH-R48MES-230VO Submittal (PDF)\u003c\/a\u003e\u003c\/li\u003e\n      \u003cli\u003e\u003ca rel=\"noopener\" href=\"https:\/\/media.cooperandhunter.us\/4450\/CH-R48MES-230VO-non.pdf\" target=\"_blank\"\u003eCH-R48MES-230VO Submittal — Non-Ducted (PDF)\u003c\/a\u003e\u003c\/li\u003e\n      \u003cli\u003e\u003ca rel=\"noopener\" href=\"https:\/\/media.cooperandhunter.us\/4442\/Installation-manual-Multi-R.pdf\" target=\"_blank\"\u003eInstallation Manual — Multi-R (PDF)\u003c\/a\u003e\u003c\/li\u003e\n      \u003cli\u003e\u003ca rel=\"noopener\" href=\"https:\/\/media.cooperandhunter.us\/3198\/MultiZone-Combination-HYPER.pdf\" target=\"_blank\"\u003eMulti-Zone Combination — HYPER (PDF)\u003c\/a\u003e\u003c\/li\u003e\n      \u003cli\u003e\u003ca rel=\"noopener\" href=\"https:\/\/media.cooperandhunter.us\/3199\/MultiZone-Combination-Regular.pdf\" target=\"_blank\"\u003eMulti-Zone Combination — Regular (PDF)\u003c\/a\u003e\u003c\/li\u003e\n    \u003c\/ul\u003e\n    \u003cp class=\"hvx-note\"\u003eAHRI certification numbers (reference): Ducted 215864263 · Non-Ducted 215864264 · Mixed 215864265.\u003c\/p\u003e\n  \u003c\/div\u003e\n\n  \u003cdiv class=\"hvx-desc-card\"\u003e\n    \u003ch2 class=\"hvx-section-title\"\u003eImportant\u003c\/h2\u003e\n    \u003cp style=\"font-size: 14px; color: var(--hvx-slate); margin: 0;\" class=\"hvx-note\"\u003e\n      Install by a licensed HVAC professional. Confirm indoor unit combinations, voltage range (187–253 V), MCA\/max-fuse,\n      refrigerant piping per zone (including the 1\/2″ gas circuits), height limits, and ambient operating ranges before commissioning.\n    \u003c\/p\u003e\n  \u003c\/div\u003e\n\n  \u003cdiv class=\"hvx-desc-card\"\u003e\n    \u003ch2 class=\"hvx-section-title\"\u003eFAQs\u003c\/h2\u003e\n\n    \u003cdetails open class=\"hvx-faq\"\u003e\n      \u003csummary\u003eHow many zones can this support?\u003c\/summary\u003e\n      \u003cdiv style=\"margin-top: 8px;\"\u003eUp to six independent zones with compatible Cooper\u0026amp;Hunter Hyper Multi-Zone indoor units.\u003c\/div\u003e\n    \u003c\/details\u003e\n\n    \u003cdetails open class=\"hvx-faq\"\u003e\n      \u003csummary\u003eWhat line sizes are required?\u003c\/summary\u003e\n      \u003cdiv style=\"margin-top: 8px;\"\u003eSix circuits total: 6× 1\/4″ liquid; gas connections are 4× 3\/8″ plus 2× 1\/2″.\u003c\/div\u003e\n    \u003c\/details\u003e\n\n    \u003cdetails open class=\"hvx-faq\"\u003e\n      \u003csummary\u003eWhat are the power requirements?\u003c\/summary\u003e\n      \u003cdiv style=\"margin-top: 8px;\"\u003e208–230 V, single-phase, 60 Hz. Voltage range 187–253 V. MCA 34 A. Max fuse 40 A.\u003c\/div\u003e\n    \u003c\/details\u003e\n\n    \u003cdetails open class=\"hvx-faq\"\u003e\n      \u003csummary\u003eWhat refrigerant does it use?\u003c\/summary\u003e\n      \u003cdiv style=\"margin-top: 8px;\"\u003eR454B.\u003c\/div\u003e\n    \u003c\/details\u003e\n\n    \u003cdetails open class=\"hvx-faq\"\u003e\n      \u003csummary\u003eWhat are the operating temperature ranges?\u003c\/summary\u003e\n      \u003cdiv style=\"margin-top: 8px;\"\u003eCooling: −13 to 122 °F. Heating: −13 to 75 °F.\u003c\/div\u003e\n    \u003c\/details\u003e\n\n    \u003cdetails open class=\"hvx-faq\"\u003e\n      \u003csummary\u003eHow efficient is this outdoor unit?\u003c\/summary\u003e\n      \u003cdiv style=\"margin-top: 8px;\"\u003eRated up to 24 SEER2 and 12.5 EER2. HSPF2 is 10.3 (Region IV) \/ 8.0 (Region V).\u003c\/div\u003e\n    \u003c\/details\u003e\n  \u003c\/div\u003e\n\u003c\/div\u003e\n","brand":"Cooper\u0026Hunter","offers":[{"title":"Default Title","offer_id":42697688809515,"sku":"CH-R48MES-230VO","price":4141.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0625\/5647\/1339\/files\/48000_BTU_1_0e74ef3f-f3aa-4d8c-9b11-c5cf360e6739.png?v=1769188285"},{"product_id":"cooper-hunter-multi-zone-r454b-outdoor-condenser-60-000-btu-5-ton","title":"Cooper\u0026Hunter Multi-Zone R454B Outdoor Condenser 60,000 BTU (5 Ton)","description":"\u003cstyle\u003e\n  :root{\n    --hvx-golden:#FAA819;\n    --hvx-slate:#262626;\n    --hvx-ivory:#F4F1E6;\n    --hvx-border:#e2e0d5;\n    --hvx-card-bg:#ffffff;\n  }\n\n  .hvx-desc{\n    font-family:\"Articulat CF\",system-ui,-apple-system,BlinkMacSystemFont,\"Segoe UI\",sans-serif;\n    color:var(--hvx-slate);\n    line-height:1.6;\n    background:var(--hvx-ivory);\n    padding:18px 18px 20px;\n    border-radius:16px;\n  }\n\n  .hvx-desc-header{\n    border-radius:14px;\n    padding:14px 16px;\n    background:linear-gradient(120deg,var(--hvx-golden),var(--hvx-slate));\n    color:#fff;\n    margin:0 0 16px;\n    box-shadow:0 10px 24px rgba(0,0,0,.22);\n    display:flex;\n    align-items:flex-start;\n    gap:12px;\n    flex-wrap:wrap;\n  }\n\n  .hvx-header-text{display:flex;flex-direction:column;gap:4px;min-width:260px}\n  .hvx-eyebrow{\n    font-size:11px;\n    letter-spacing:.14em;\n    text-transform:uppercase;\n    opacity:.9;\n  }\n  .hvx-title{\n    margin:0;\n    font-family:\"Anton\",\"Impact\",system-ui,-apple-system,BlinkMacSystemFont,\"Segoe UI\",sans-serif;\n    font-size:22px;\n    line-height:1.15;\n  }\n\n  .hvx-desc-card{\n    border:1px solid var(--hvx-border);\n    border-radius:14px;\n    background:var(--hvx-card-bg);\n    padding:16px 18px 18px;\n    box-shadow:0 4px 12px rgba(0,0,0,.06);\n    margin:14px 0;\n  }\n\n  .hvx-section-title{\n    margin:0 0 10px;\n    font-family:\"Anton\",\"Impact\",system-ui,-apple-system,BlinkMacSystemFont,\"Segoe UI\",sans-serif;\n    font-size:17px;\n    letter-spacing:.08em;\n    text-transform:uppercase;\n    color:var(--hvx-slate);\n    display:inline-flex;\n    align-items:center;\n    gap:8px;\n  }\n  .hvx-section-title::after{\n    content:\"\";\n    flex:1;\n    height:2px;\n    border-radius:999px;\n    background:linear-gradient(90deg,var(--hvx-golden),transparent);\n    opacity:.9;\n  }\n\n  .hvx-cta{display:flex;flex-wrap:wrap;gap:10px;margin:10px 0 0}\n  .hvx-cta a{\n    display:inline-flex;\n    align-items:center;\n    gap:8px;\n    padding:10px 14px;\n    border-radius:12px;\n    border:1px solid var(--hvx-border);\n    background:#fff;\n    text-decoration:none;\n    color:var(--hvx-slate);\n    font-size:14px;\n    font-weight:700;\n  }\n  .hvx-cta a.primary{\n    background:var(--hvx-slate);\n    color:#fff;\n    border-color:transparent;\n  }\n\n  .hvx-badges{display:flex;flex-wrap:wrap;gap:8px;margin:10px 0 0}\n  .hvx-badge{\n    font-size:12px;\n    border:1px solid var(--hvx-border);\n    border-radius:999px;\n    padding:6px 10px;\n    background:#fff;\n    white-space:nowrap;\n  }\n\n  .hvx-kv{\n    display:grid;\n    grid-template-columns:repeat(4,minmax(160px,1fr));\n    gap:10px;\n    margin-top:10px;\n  }\n  .hvx-kv \u003e div{\n    border:1px solid var(--hvx-border);\n    background:#fff;\n    border-radius:12px;\n    padding:10px 12px;\n    text-align:center;\n  }\n  .hvx-kv strong{display:block}\n\n  .hvx-table{\n    width:100%;\n    border-collapse:collapse;\n    min-width:520px;\n    background:#fff;\n    border:1px solid var(--hvx-border);\n    border-radius:12px;\n    overflow:hidden;\n  }\n  .hvx-table th,.hvx-table td{\n    border-bottom:1px solid var(--hvx-border);\n    padding:10px 12px;\n    vertical-align:top;\n    font-size:14px;\n  }\n  .hvx-table th{ text-align:left; font-weight:800; background:#fff; }\n  .hvx-table tr:nth-child(odd) td{ background:#fff; }\n  .hvx-table tr:nth-child(even) td{ background:#fbfaf6; }\n  .hvx-table tr:last-child td{ border-bottom:none; }\n  .hvx-table-wrap{ overflow:auto; border-radius:12px; }\n\n  .hvx-note{\n    font-size:12px;\n    color:#555;\n    margin:10px 0 0;\n  }\n\n  details.hvx-faq{\n    border:1px solid var(--hvx-border);\n    background:#fff;\n    border-radius:12px;\n    padding:10px 12px;\n    margin:8px 0;\n  }\n  details.hvx-faq summary{\n    cursor:pointer;\n    font-weight:800;\n  }\n\n  @media(max-width:980px){\n    .hvx-kv{grid-template-columns:repeat(2,minmax(160px,1fr))}\n  }\n  @media(max-width:768px){\n    .hvx-desc{padding:14px 12px 16px;border-radius:12px}\n    .hvx-desc-header{padding:12px;border-radius:12px}\n    .hvx-title{font-size:19px}\n    .hvx-desc-card{padding:14px;margin:10px 0}\n  }\n\u003c\/style\u003e\n\u003cdiv class=\"hvx-desc\"\u003e\n\u003cdiv class=\"hvx-desc-header\"\u003e\n\u003cdiv class=\"hvx-header-text\"\u003e\n\u003cdiv class=\"hvx-eyebrow\"\u003eCooper\u0026amp;Hunter Hyper Multi-Zone Outdoor • R454B • Multi-Zone\u003c\/div\u003e\n\u003ch1 class=\"hvx-title\"\u003eCooper\u0026amp;Hunter Hyper Multi-Zone Outdoor — 60,000 BTU, R454B — CH-R60MES-230VO\u003c\/h1\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"hvx-cta\" aria-label=\"Contact options\"\u003e\n\u003ca class=\"primary\" href=\"https:\/\/hvacsupplies.com\/pages\/contact\" rel=\"noopener\" title=\"Contact Us\" target=\"_blank\"\u003e CLICK HERE TO CONTACT US FOR CUSTOM QUOTES AND QUESTIONS \u003c\/a\u003e \u003ca href=\"tel:+18005438933\" title=\"Call Us Now!\"\u003e CLICK TO CALL US 1-800-543-8933 FOR ANY QUESTIONS \u003c\/a\u003e \u003cbr\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"hvx-desc-card\"\u003e\n\u003ch2 class=\"hvx-section-title\"\u003eOverview\u003c\/h2\u003e\n\u003cp style=\"margin: 0;\"\u003eCooper\u0026amp;Hunter’s 60K BTU Hyper Multi-Zone outdoor unit is an advanced solution for efficient climate control in large residential spaces. Supporting up to six zones, it enables independent temperature settings across multiple areas for tailored comfort. Cutting-edge inverter technology dynamically adjusts compressor activity to match load demands, optimizing energy usage while maintaining consistent performance. With up to 22 SEER2 efficiency and R454B refrigerant (lower GWP vs. many conventional options), it’s designed for reliable, eco-conscious multi-zone installations built for year-round comfort.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"hvx-desc-card\"\u003e\n\u003ch2 class=\"hvx-section-title\"\u003eHighlights\u003c\/h2\u003e\n\u003cdiv class=\"hvx-badges\" role=\"list\"\u003e\n\u003cspan class=\"hvx-badge\" role=\"listitem\"\u003e60,000 BTU cool (19,000–62,000)\u003c\/span\u003e \u003cspan class=\"hvx-badge\" role=\"listitem\"\u003e60,000 BTU heat (20,000–60,000)\u003c\/span\u003e \u003cspan class=\"hvx-badge\" role=\"listitem\"\u003eUp to 6 zones\u003c\/span\u003e \u003cspan class=\"hvx-badge\" role=\"listitem\"\u003eSEER2 22 · EER2 10\u003c\/span\u003e \u003cspan class=\"hvx-badge\" role=\"listitem\"\u003eHSPF2 9.5 (Region IV) · 7.4 (Region V)\u003c\/span\u003e \u003cspan class=\"hvx-badge\" role=\"listitem\"\u003eCOP 3.7\u003c\/span\u003e \u003cspan class=\"hvx-badge\" role=\"listitem\"\u003eR454B\u003c\/span\u003e \u003cspan class=\"hvx-badge\" role=\"listitem\"\u003e208–230V 1Ph\u003c\/span\u003e \u003cspan class=\"hvx-badge\" role=\"listitem\"\u003e−13–122 °F cool · −13–75 °F heat\u003c\/span\u003e\n\u003c\/div\u003e\n\u003cul style=\"margin: 12px 0 0; padding-left: 18px;\"\u003e\n\u003cli\u003e\n\u003cstrong\u003eMulti-zone flexibility:\u003c\/strong\u003e supports up to 6 independent zones with compatible indoor units.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOptimized efficiency:\u003c\/strong\u003e up to 22 SEER2 for meaningful seasonal energy savings.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInverter performance:\u003c\/strong\u003e dynamic compressor modulation helps maintain steady comfort under varying loads.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEco-forward refrigerant:\u003c\/strong\u003e uses R454B to reduce environmental impact.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBuilt for large spaces:\u003c\/strong\u003e strong capacity and multi-room control for bigger layouts.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cdiv class=\"hvx-kv\" role=\"list\" aria-label=\"At-a-glance\"\u003e\n\u003cdiv role=\"listitem\"\u003e\n\u003cstrong\u003eModel\u003c\/strong\u003eCH-R60MES-230VO\u003c\/div\u003e\n\u003cdiv role=\"listitem\"\u003e\n\u003cstrong\u003eZones\u003c\/strong\u003eUp to 6\u003c\/div\u003e\n\u003cdiv role=\"listitem\"\u003e\n\u003cstrong\u003eOutdoor Sound\u003c\/strong\u003e65 dB(A)\u003c\/div\u003e\n\u003cdiv role=\"listitem\"\u003e\n\u003cstrong\u003eLines\u003c\/strong\u003e6× 1\/4″ liquid · (4× 3\/8″ + 2× 1\/2″) gas\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"hvx-desc-card\"\u003e\n\u003ch2 class=\"hvx-section-title\"\u003eWhat's Included\u003c\/h2\u003e\n\u003cul style=\"padding-left: 18px; margin: 8px 0;\"\u003e\n\u003cli\u003eOutdoor unit CH-R60MES-230VO\u003c\/li\u003e\n\u003cli\u003eOwner \/ installation documentation\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp class=\"hvx-note\"\u003ePair only with compatible Cooper\u0026amp;Hunter Hyper Multi-Zone indoor units. Confirm zone combinations and piping requirements before installation.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"hvx-desc-card\"\u003e\n\u003ch2 class=\"hvx-section-title\"\u003eIndoor Specs\u003c\/h2\u003e\n\u003cdiv class=\"hvx-table-wrap\"\u003e\n\u003ctable class=\"hvx-table\" aria-label=\"Indoor unit compatibility\"\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eSpec\u003c\/th\u003e\n\u003cth\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSystem type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMulti-zone unit (outdoor)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eZones supported\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eUp to 6 independent zones (depends on indoor unit selection)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCompatible indoor units\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCooper\u0026amp;Hunter Hyper Multi-Zone indoor units (zone mix varies by combination)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRefrigerant piping (per zone)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e6 circuits total: 6× 1\/4″ liquid; gas connections are 4× 3\/8″ + 2× 1\/2″\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMax height difference (IDU↔ODU)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e49.2 ft\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCombination guidance\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eUse the provided Multi-Zone Combination PDFs to confirm valid indoor mixes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003cp class=\"hvx-note\"\u003eIndoor-unit capacities, features, and controls depend on the specific indoor models selected for each zone.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"hvx-desc-card\"\u003e\n\u003ch2 class=\"hvx-section-title\"\u003eOutdoor Specs\u003c\/h2\u003e\n\u003cdiv class=\"hvx-table-wrap\"\u003e\n\u003ctable class=\"hvx-table\" aria-label=\"Outdoor unit specifications\"\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eSpec\u003c\/th\u003e\n\u003cth\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCH-R60MES-230VO\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRefrigerant type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eR454B\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower source\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e208–230V, 1Ph, 60Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eVoltage range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e187–253 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCooling capacity (Min\/Max)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e60,000 BTU\/h (19,000–62,000)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eHeating capacity (Min\/Max)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e60,000 BTU\/h (20,000–60,000)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSEER2 \/ EER2\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e22 \/ 10\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eHSPF2-4 \/ HSPF2-5\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e9.5 \/ 7.4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCOP\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3.7\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMinimum circuit ampacity (MCA)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e36 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMax fuse\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e40 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOutdoor Air Flow\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4,502.8 CFM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOutdoor Noise Level\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e65 dB(A)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDehumidification\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e10.57 pints\/day\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eUnit dimensions (W×H×D)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e37.48 × 16.34 × 52.48 in\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePacking dimensions (W×D×H)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e43.11 × 19.49 × 58.27 in\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNet \/ Gross weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e237.88 \/ 270.28 lb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRefrigerant precharge\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e150 (factory charge)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRefrigerant piping (Liquid\/Gas)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e6× 1\/4″ liquid · (4× 3\/8″ + 2× 1\/2″) gas\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAmbient temperature — Heating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e−13 to 75 °F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAmbient temperature — Cooling\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e−13 to 122 °F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAdditional refrigerant charge — 3\/8″ liquid line\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.32\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAdditional refrigerant charge — 1\/4″ liquid line\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.16\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"hvx-desc-card\"\u003e\n\u003ch2 class=\"hvx-section-title\"\u003eDocuments \u0026amp; Downloads\u003c\/h2\u003e\n\u003cul style=\"padding-left: 18px; margin: 8px 0;\"\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/media.cooperandhunter.us\/4451\/CH-R60MES-230VO.pdf\" rel=\"noopener\" target=\"_blank\"\u003eCH-R60MES-230VO Submittal (PDF)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/media.cooperandhunter.us\/4452\/CH-R60MES-230VO-non.pdf\" rel=\"noopener\" target=\"_blank\"\u003eCH-R60MES-230VO Submittal — Non-Ducted (PDF)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/media.cooperandhunter.us\/4442\/Installation-manual-Multi-R.pdf\" rel=\"noopener\" target=\"_blank\"\u003eInstallation Manual — Multi-R (PDF)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/media.cooperandhunter.us\/3198\/MultiZone-Combination-HYPER.pdf\" rel=\"noopener\" target=\"_blank\"\u003eMulti-Zone Combination — HYPER (PDF)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/media.cooperandhunter.us\/3199\/MultiZone-Combination-Regular.pdf\" rel=\"noopener\" target=\"_blank\"\u003eMulti-Zone Combination — Regular (PDF)\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp class=\"hvx-note\"\u003eAHRI certification numbers (reference): Ducted 215864266 · Non-Ducted 215864267 · Mixed 215864268.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"hvx-desc-card\"\u003e\n\u003ch2 class=\"hvx-section-title\"\u003eImportant\u003c\/h2\u003e\n\u003cp class=\"hvx-note\" style=\"font-size: 14px; color: var(--hvx-slate); margin: 0;\"\u003eInstall by a licensed HVAC professional. Confirm indoor unit combinations, voltage range (187–253 V), MCA\/max-fuse, refrigerant piping per zone (including the 1\/2″ gas circuits), height limits, and ambient operating ranges before commissioning.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"hvx-desc-card\"\u003e\n\u003ch2 class=\"hvx-section-title\"\u003eFAQs\u003c\/h2\u003e\n\u003cdetails class=\"hvx-faq\" open=\"\"\u003e\n\u003csummary\u003eHow many zones can this support?\u003c\/summary\u003e\n\u003cdiv style=\"margin-top: 8px;\"\u003eUp to six independent zones with compatible Cooper\u0026amp;Hunter Hyper Multi-Zone indoor units.\u003c\/div\u003e\n\u003c\/details\u003e\n\u003cdetails class=\"hvx-faq\" open=\"\"\u003e\n\u003csummary\u003eWhat line sizes are required?\u003c\/summary\u003e\n\u003cdiv style=\"margin-top: 8px;\"\u003eSix circuits total: 6× 1\/4″ liquid; gas connections are 4× 3\/8″ plus 2× 1\/2″.\u003c\/div\u003e\n\u003c\/details\u003e\n\u003cdetails class=\"hvx-faq\" open=\"\"\u003e\n\u003csummary\u003eWhat are the power requirements?\u003c\/summary\u003e\n\u003cdiv style=\"margin-top: 8px;\"\u003e208–230 V, single-phase, 60 Hz. Voltage range 187–253 V. MCA 36 A. Max fuse 40 A.\u003c\/div\u003e\n\u003c\/details\u003e\n\u003cdetails class=\"hvx-faq\" open=\"\"\u003e\n\u003csummary\u003eWhat refrigerant does it use?\u003c\/summary\u003e\n\u003cdiv style=\"margin-top: 8px;\"\u003eR454B.\u003c\/div\u003e\n\u003c\/details\u003e\n\u003cdetails class=\"hvx-faq\" open=\"\"\u003e\n\u003csummary\u003eWhat are the operating temperature ranges?\u003c\/summary\u003e\n\u003cdiv style=\"margin-top: 8px;\"\u003eCooling: −13 to 122 °F. Heating: −13 to 75 °F.\u003c\/div\u003e\n\u003c\/details\u003e\n\u003cdetails class=\"hvx-faq\" open=\"\"\u003e\n\u003csummary\u003eHow efficient is this outdoor unit?\u003c\/summary\u003e\n\u003cdiv style=\"margin-top: 8px;\"\u003eRated up to 22 SEER2 and 10 EER2. HSPF2 is 9.5 (Region IV) \/ 7.4 (Region V).\u003c\/div\u003e\n\u003c\/details\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e","brand":"Cooper\u0026Hunter","offers":[{"title":"Default Title","offer_id":42697719119915,"sku":"CH-R60MES-230VO","price":4356.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0625\/5647\/1339\/files\/OliviaMidnight-38_1.png?v=1768419041"},{"product_id":"cooper-hunter-multi-zone-r410a-outdoor-condenser-18-000-btu-1-5-ton","title":"Cooper\u0026Hunter Multi-Zone R410A Outdoor Condenser 18,000 BTU (1.5 Ton)","description":"\u003cstyle\u003e\n  :root{\n    --hvx-golden:#FAA819;\n    --hvx-slate:#262626;\n    --hvx-ivory:#F4F1E6;\n    --hvx-border:#e2e0d5;\n    --hvx-card-bg:#ffffff;\n  }\n\n  .hvx-desc{\n    font-family:\"Articulat CF\",system-ui,-apple-system,BlinkMacSystemFont,\"Segoe UI\",sans-serif;\n    color:var(--hvx-slate);\n    line-height:1.6;\n    background:var(--hvx-ivory);\n    padding:18px 18px 20px;\n    border-radius:16px;\n  }\n\n  .hvx-desc-header{\n    border-radius:14px;\n    padding:14px 16px;\n    background:linear-gradient(120deg,var(--hvx-golden),var(--hvx-slate));\n    color:#fff;\n    margin:0 0 16px;\n    box-shadow:0 10px 24px rgba(0,0,0,.22);\n    display:flex;\n    align-items:flex-start;\n    gap:12px;\n    flex-wrap:wrap;\n  }\n\n  .hvx-header-text{display:flex;flex-direction:column;gap:6px;min-width:260px}\n  .hvx-eyebrow{\n    font-size:11px;\n    letter-spacing:.14em;\n    text-transform:uppercase;\n    opacity:.9;\n  }\n  .hvx-title{\n    margin:0;\n    font-family:\"Anton\",\"Impact\",system-ui,-apple-system,BlinkMacSystemFont,\"Segoe UI\",sans-serif;\n    font-size:22px;\n    line-height:1.15;\n  }\n  .hvx-subtitle{\n    margin:0;\n    font-size:14px;\n    opacity:.95;\n  }\n\n  .hvx-desc-card{\n    border:1px solid var(--hvx-border);\n    border-radius:14px;\n    background:var(--hvx-card-bg);\n    padding:16px 18px 18px;\n    box-shadow:0 4px 12px rgba(0,0,0,.06);\n    margin:14px 0;\n  }\n\n  .hvx-section-title{\n    margin:0 0 10px;\n    font-family:\"Anton\",\"Impact\",system-ui,-apple-system,BlinkMacSystemFont,\"Segoe UI\",sans-serif;\n    font-size:17px;\n    letter-spacing:.08em;\n    text-transform:uppercase;\n    color:var(--hvx-slate);\n    display:inline-flex;\n    align-items:center;\n    gap:8px;\n  }\n  .hvx-section-title::after{\n    content:\"\";\n    flex:1;\n    height:2px;\n    border-radius:999px;\n    background:linear-gradient(90deg,var(--hvx-golden),transparent);\n    opacity:.9;\n  }\n\n  .hvx-cta{display:flex;flex-wrap:wrap;gap:10px;margin:10px 0 0}\n  .hvx-cta a{\n    display:inline-flex;\n    align-items:center;\n    gap:8px;\n    padding:10px 14px;\n    border-radius:12px;\n    border:1px solid var(--hvx-border);\n    background:#fff;\n    text-decoration:none;\n    color:var(--hvx-slate);\n    font-size:14px;\n    font-weight:700;\n  }\n  .hvx-cta a.primary{\n    background:var(--hvx-slate);\n    color:#fff;\n    border-color:transparent;\n  }\n\n  .hvx-badges{display:flex;flex-wrap:wrap;gap:8px;margin:10px 0 0}\n  .hvx-badge{\n    font-size:12px;\n    border:1px solid var(--hvx-border);\n    border-radius:999px;\n    padding:6px 10px;\n    background:#fff;\n    white-space:nowrap;\n  }\n\n  .hvx-kv{\n    display:grid;\n    grid-template-columns:repeat(4,minmax(160px,1fr));\n    gap:10px;\n    margin-top:10px;\n  }\n  .hvx-kv \u003e div{\n    border:1px solid var(--hvx-border);\n    background:#fff;\n    border-radius:12px;\n    padding:10px 12px;\n    text-align:center;\n  }\n  .hvx-kv strong{display:block}\n\n  .hvx-table{\n    width:100%;\n    border-collapse:collapse;\n    min-width:520px;\n    background:#fff;\n    border:1px solid var(--hvx-border);\n    border-radius:12px;\n    overflow:hidden;\n  }\n  .hvx-table th,.hvx-table td{\n    border-bottom:1px solid var(--hvx-border);\n    padding:10px 12px;\n    vertical-align:top;\n    font-size:14px;\n  }\n  .hvx-table th{ text-align:left; font-weight:800; background:#fff; }\n  .hvx-table tr:nth-child(even) td{ background:#fbfaf6; }\n  .hvx-table tr:last-child td{ border-bottom:none; }\n  .hvx-table-wrap{ overflow:auto; border-radius:12px; }\n\n  .hvx-link{color:var(--hvx-slate); text-decoration:underline; text-underline-offset:2px}\n  .hvx-link:hover{opacity:.85}\n\n  details.hvx-faq{\n    border:1px solid var(--hvx-border);\n    background:#fff;\n    border-radius:12px;\n    padding:10px 12px;\n    margin:8px 0;\n  }\n  details.hvx-faq summary{cursor:pointer;font-weight:800;}\n\n  @media(max-width:980px){\n    .hvx-kv{grid-template-columns:repeat(2,minmax(160px,1fr))}\n  }\n  @media(max-width:768px){\n    .hvx-desc{padding:14px 12px 16px;border-radius:12px}\n    .hvx-desc-header{padding:12px;border-radius:12px}\n    .hvx-title{font-size:19px}\n    .hvx-desc-card{padding:14px;margin:10px 0}\n  }\n\u003c\/style\u003e\n\u003cdiv class=\"hvx-desc\"\u003e\n\u003cdiv class=\"hvx-desc-header\"\u003e\n\u003cdiv class=\"hvx-header-text\"\u003e\n\u003cdiv class=\"hvx-eyebrow\"\u003eCooper\u0026amp;Hunter ES Multi-Zone Outdoor Condenser • R410A • 230V\u003c\/div\u003e\n\u003ch1 class=\"hvx-title\"\u003eCooper\u0026amp;Hunter 18,000 BTU Multi-Zone Outdoor Condenser (1.5 Ton) — CH-18MES-230VO\u003c\/h1\u003e\n\u003cp class=\"hvx-subtitle\"\u003eEnergy Star–listed ES series multi-zone condenser for pairing with multiple indoor unit styles, supporting up to 24 SEER (system dependent).\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv aria-label=\"Contact options\" class=\"hvx-cta\"\u003e\n\u003ca title=\"Contact Us\" rel=\"noopener\" href=\"https:\/\/hvacsupplies.com\/pages\/contact\" class=\"primary\" target=\"_blank\"\u003eCLICK HERE TO CONTACT US FOR CUSTOM QUOTES AND QUESTIONS\u003c\/a\u003e \u003ca title=\"Call Us Now!\" href=\"tel:+18005438933\"\u003eCLICK TO CALL US 1-800-543-8933 FOR ANY QUESTIONS\u003c\/a\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"hvx-desc-card\"\u003e\n\u003ch2 class=\"hvx-section-title\"\u003eOverview\u003c\/h2\u003e\n\u003cp style=\"margin: 0;\"\u003eThe Cooper\u0026amp;Hunter \u003cstrong\u003eES condenser series\u003c\/strong\u003e includes Energy Star Certified options in 9K, 12K, 18K, and 24K capacities. ES condensers are available in both \u003cstrong\u003esingle\u003c\/strong\u003e and \u003cstrong\u003emulti-zone\u003c\/strong\u003e configurations and can be paired with a wide range of indoor unit styles—including wall mounts, ceiling cassettes, slim ducts, universal floor\/ceiling units, mini floor consoles, and air handlers (match-up dependent). \u003cbr\u003e\u003cbr\u003eThe \u003cstrong\u003eCH-18MES-230VO\u003c\/strong\u003e is a \u003cstrong\u003emulti-zone\u003c\/strong\u003e outdoor condenser rated at \u003cstrong\u003e18,000 BTU\u003c\/strong\u003e (1.5 ton) using \u003cstrong\u003eR410A\u003c\/strong\u003e refrigerant on \u003cstrong\u003e208–230V\u003c\/strong\u003e power. It supports total piping up to \u003cstrong\u003e131 ft\u003c\/strong\u003e and a maximum indoor\/outdoor height difference up to \u003cstrong\u003e49.21 ft\u003c\/strong\u003e. Ambient operating ranges are broad, with cooling down to \u003cstrong\u003e5°F\u003c\/strong\u003e and heating down to \u003cstrong\u003e-13°F\u003c\/strong\u003e.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"hvx-desc-card\"\u003e\n\u003ch2 class=\"hvx-section-title\"\u003eHighlights\u003c\/h2\u003e\n\u003cdiv role=\"list\" class=\"hvx-badges\"\u003e\n\u003cspan role=\"listitem\" class=\"hvx-badge\"\u003e18,000 BTU (rated)\u003c\/span\u003e \u003cspan role=\"listitem\" class=\"hvx-badge\"\u003eMulti-Zone\u003c\/span\u003e \u003cspan role=\"listitem\" class=\"hvx-badge\"\u003eR410A\u003c\/span\u003e \u003cspan role=\"listitem\" class=\"hvx-badge\"\u003eSEER2 19\u003c\/span\u003e \u003cspan role=\"listitem\" class=\"hvx-badge\"\u003eEER2 12\u003c\/span\u003e \u003cspan role=\"listitem\" class=\"hvx-badge\"\u003eHSPF2-4 9.8\u003c\/span\u003e \u003cspan role=\"listitem\" class=\"hvx-badge\"\u003eHSPF2-5 7.6\u003c\/span\u003e \u003cspan role=\"listitem\" class=\"hvx-badge\"\u003eMax Pipe 131 ft\u003c\/span\u003e \u003cspan role=\"listitem\" class=\"hvx-badge\"\u003eOutdoor Sound 58.5 dB(A)\u003c\/span\u003e \u003cspan role=\"listitem\" class=\"hvx-badge\"\u003ePrecharge up to 50 ft\u003c\/span\u003e \u003cspan role=\"listitem\" class=\"hvx-badge\"\u003e5°F Cooling \/ -13°F Heating\u003c\/span\u003e\n\u003c\/div\u003e\n\u003cul style=\"margin: 12px 0 0; padding-left: 18px;\"\u003e\n\u003cli\u003e\n\u003cstrong\u003eMulti-zone flexibility:\u003c\/strong\u003e Designed to serve multiple indoor units (match-up dependent).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSystem efficiency:\u003c\/strong\u003e Rated \u003cstrong\u003eSEER2 19\u003c\/strong\u003e and \u003cstrong\u003eEER2 12\u003c\/strong\u003e (system dependent).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWide operating range:\u003c\/strong\u003e Cooling \u003cstrong\u003e5–122°F\u003c\/strong\u003e; heating \u003cstrong\u003e-13–75°F\u003c\/strong\u003e.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCapacity modulation:\u003c\/strong\u003e Cooling range \u003cstrong\u003e3,850–22,400 BTU\/h\u003c\/strong\u003e; heating range \u003cstrong\u003e4,350–25,800 BTU\/h\u003c\/strong\u003e.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInstallation parameters:\u003c\/strong\u003e Max total piping \u003cstrong\u003e131 ft\u003c\/strong\u003e and height difference up to \u003cstrong\u003e49.21 ft\u003c\/strong\u003e.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eService planning:\u003c\/strong\u003e Additional refrigerant charge guidance included for 1\/4\" and 3\/8\" liquid lines.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cdiv aria-label=\"At-a-glance\" role=\"list\" class=\"hvx-kv\"\u003e\n\u003cdiv role=\"listitem\"\u003e\n\u003cstrong\u003eModel\u003c\/strong\u003eCH-18MES-230VO\u003c\/div\u003e\n\u003cdiv role=\"listitem\"\u003e\n\u003cstrong\u003eSystem Type\u003c\/strong\u003eMulti-Zone\u003c\/div\u003e\n\u003cdiv role=\"listitem\"\u003e\n\u003cstrong\u003ePorts\u003c\/strong\u003e2 Zones (2× liq \/ 2× gas)\u003c\/div\u003e\n\u003cdiv role=\"listitem\"\u003e\n\u003cstrong\u003ePower\u003c\/strong\u003e208–230V, 1Ph\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"hvx-desc-card\"\u003e\n\u003ch2 class=\"hvx-section-title\"\u003eWhat's Included\u003c\/h2\u003e\n\u003cul style=\"padding-left: 18px; margin: 8px 0;\"\u003e\n\u003cli\u003eOutdoor condenser unit: \u003cstrong\u003eCH-18MES-230VO\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"hvx-desc-card\"\u003e\n\u003ch2 class=\"hvx-section-title\"\u003eOutdoor Specs\u003c\/h2\u003e\n\u003cdiv class=\"hvx-table-wrap\"\u003e\n\u003ctable aria-label=\"Outdoor unit specifications\" class=\"hvx-table\"\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eSpec\u003c\/th\u003e\n\u003cth\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCH-18MES-230VO\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRefrigerant Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eR410A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSystem Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMulti-zone unit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBTU Rated\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e18,000\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCooling Capacity (Min\/Max)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e18,000 (3,850–22,400) BTU\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eHeating Capacity (Min\/Max)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e19,000 (4,350–25,800) BTU\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSEER2 \/ EER2\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e19 \/ 12\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eHSPF2-4 \/ HSPF2-5\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e9.8 \/ 7.6\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCOP\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3.62\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower Source\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e208–230V, 1Ph, 60Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eVoltage Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e187–253 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMinimum Circuit Ampacity (MCA)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e18 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMax Fuse\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e25 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMax Pipe Length\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e131 ft\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMax Height Difference (Indoor↔Outdoor)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e49.21 ft\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRefrigerant Piping (Liquid \/ Gas)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2× 1\/4\" (liq) \/ 2× 3\/8\" (gas)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRefrigerant Precharge\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eUp to 50 ft\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOutdoor Noise\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e58.5 dB(A)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOutdoor Air Flow\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1,764.71\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAmbient Range (Cooling)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e5–122 °F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAmbient Range (Heating)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-13–75 °F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAdditional Charge (3\/8\" liquid)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.32\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAdditional Charge (1\/4\" liquid)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.16\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eUnit Dimensions (W×H×D)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e35.04 × 13.46 × 26.50 in\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eUnit Net \/ Gross Weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e100.31 \/ 108.69 lb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePacking Dimensions (W×D×H)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e40.55 × 17.24 × 29.53\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDehumidification\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2.20 pints\/day\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"hvx-desc-card\"\u003e\n\u003ch2 class=\"hvx-section-title\"\u003eVideos\u003c\/h2\u003e\n\u003cdiv style=\"margin: 8px 0 0;\"\u003e\n\u003cdiv style=\"font-weight: 800; margin: 10px 0 6px;\"\u003eMini-split installation videos\u003c\/div\u003e\n\u003cul style=\"padding-left: 18px; margin: 0;\"\u003e\n\u003cli\u003e\u003ca rel=\"noopener\" href=\"https:\/\/youtu.be\/Cxuiytm_CMo\" class=\"hvx-link\" target=\"_blank\"\u003eHow to Install Multi Zone Mini Split System (Cooper\u0026amp;Hunter) 2020\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca rel=\"noopener\" href=\"https:\/\/youtu.be\/EU4Jd6QYgFE\" class=\"hvx-link\" target=\"_blank\"\u003eCooper\u0026amp;Hunter Outdoor Wall Mounting Bracket\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca rel=\"noopener\" href=\"https:\/\/youtu.be\/JQkth-AM5CE\" class=\"hvx-link\" target=\"_blank\"\u003eFull Installation of Mini Split Ductless Unit, Step by Step!\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"margin: 12px 0 0;\"\u003e\n\u003cdiv style=\"font-weight: 800; margin: 10px 0 6px;\"\u003eHow To \u0026amp; Instructional Videos\u003c\/div\u003e\n\u003cul style=\"padding-left: 18px; margin: 0;\"\u003e\n\u003cli\u003e\u003ca rel=\"noopener\" href=\"https:\/\/youtu.be\/7mzwevkxw20\" class=\"hvx-link\" target=\"_blank\"\u003eTop Tips from Cooper\u0026amp;Hunter Mini Split User Manual\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"margin: 12px 0 0;\"\u003e\n\u003cdiv style=\"font-weight: 800; margin: 10px 0 6px;\"\u003eProducts overview\u003c\/div\u003e\n\u003cul style=\"padding-left: 18px; margin: 0;\"\u003e\n\u003cli\u003e\u003ca rel=\"noopener\" href=\"https:\/\/youtu.be\/0kUh03W9qS8\" class=\"hvx-link\" target=\"_blank\"\u003eCooper\u0026amp;Hunter: Multi Zone AC for the Home\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca rel=\"noopener\" href=\"https:\/\/youtu.be\/TCcju8Ii6L8\" class=\"hvx-link\" target=\"_blank\"\u003eMulti-Zone Mini-Split System vs Central A\/C in Home (2019) Cooper\u0026amp;Hunter\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca rel=\"noopener\" href=\"https:\/\/youtu.be\/k6CLIFdvVXk\" class=\"hvx-link\" target=\"_blank\"\u003eCooper\u0026amp;Hunter Products at AHR Expo 2020 with Robot Millennia\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca rel=\"noopener\" href=\"https:\/\/youtu.be\/2u0pa2jThCM\" class=\"hvx-link\" target=\"_blank\"\u003eHVAC Installation Kit: 99.9% Copper Line Sets (Cooper\u0026amp;Hunter)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca rel=\"noopener\" href=\"https:\/\/youtu.be\/qCWu8HCNl3Q\" class=\"hvx-link\" target=\"_blank\"\u003eMini Split Indoor Unit Types Explained\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"hvx-desc-card\"\u003e\n\u003ch2 class=\"hvx-section-title\"\u003eDocuments \u0026amp; Downloads\u003c\/h2\u003e\n\u003cul style=\"padding-left: 18px; margin: 8px 0;\"\u003e\n\u003cli\u003e\u003ca rel=\"noopener\" href=\"https:\/\/media.cooperandhunter.us\/3160\/CH-18MES-230VO-%28Ducted%29.pdf\" class=\"hvx-link\" target=\"_blank\"\u003eSubmittal — CH-18MES-230VO (Ducted) (PDF)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca rel=\"noopener\" href=\"https:\/\/media.cooperandhunter.us\/3161\/CH-18MES-230VO-%28Non-ducted%29.pdf\" class=\"hvx-link\" target=\"_blank\"\u003eSubmittal — CH-18MES-230VO (Non-Ducted) (PDF)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca rel=\"noopener\" href=\"https:\/\/media.cooperandhunter.us\/3755\/Multi-Zone-Leaflet-2024.pdf\" class=\"hvx-link\" target=\"_blank\"\u003eMulti-Zone Series — Leaflet (2024) (PDF)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca rel=\"noopener\" href=\"https:\/\/media.cooperandhunter.us\/4433\/Installation-manual.pdf\" class=\"hvx-link\" target=\"_blank\"\u003eInstallation Manual — Multi-Zone Outdoor (PDF)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca rel=\"noopener\" href=\"https:\/\/media.cooperandhunter.us\/3199\/MultiZone-Combination-Regular.pdf\" class=\"hvx-link\" target=\"_blank\"\u003eMulti-Zone Combination — Regular (PDF)\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"hvx-desc-card\"\u003e\n\u003ch2 class=\"hvx-section-title\"\u003eImportant\u003c\/h2\u003e\n\u003cp style=\"margin: 0; font-size: 14px;\"\u003eInstall with a licensed HVAC professional. This is a \u003cstrong\u003emulti-zone outdoor condenser\u003c\/strong\u003e intended to be matched with compatible indoor units. Confirm match-ups, total connected indoor capacity, and piping design before ordering. Observe maximum total piping (\u003cstrong\u003e131 ft\u003c\/strong\u003e), height limits (\u003cstrong\u003e49.21 ft\u003c\/strong\u003e), and required electrical protection (\u003cstrong\u003eMCA 18A\u003c\/strong\u003e, \u003cstrong\u003emax fuse 25A\u003c\/strong\u003e). Refrigerant is \u003cstrong\u003eR410A\u003c\/strong\u003e with factory precharge up to \u003cstrong\u003e50 ft\u003c\/strong\u003e; additional charge may be required beyond that length.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"hvx-desc-card\"\u003e\n\u003ch2 class=\"hvx-section-title\"\u003eFAQs\u003c\/h2\u003e\n\u003cdetails open=\"\" class=\"hvx-faq\"\u003e\n\u003csummary\u003eIs this a single-zone or multi-zone outdoor unit?\u003c\/summary\u003e\n\u003cdiv style=\"margin-top: 8px;\"\u003eThis model is a \u003cstrong\u003emulti-zone\u003c\/strong\u003e outdoor condenser.\u003c\/div\u003e\n\u003c\/details\u003e\n\u003cdetails open=\"\" class=\"hvx-faq\"\u003e\n\u003csummary\u003eHow many indoor units can it connect to?\u003c\/summary\u003e\n\u003cdiv style=\"margin-top: 8px;\"\u003eThe piping spec lists \u003cstrong\u003e2 sets\u003c\/strong\u003e of connections (2× liquid and 2× gas), indicating support for up to \u003cstrong\u003etwo zones\u003c\/strong\u003e when matched correctly.\u003c\/div\u003e\n\u003c\/details\u003e\n\u003cdetails open=\"\" class=\"hvx-faq\"\u003e\n\u003csummary\u003eWhat are the operating temperature ranges?\u003c\/summary\u003e\n\u003cdiv style=\"margin-top: 8px;\"\u003eCooling ambient range is \u003cstrong\u003e5–122°F\u003c\/strong\u003e. Heating ambient range is \u003cstrong\u003e-13–75°F\u003c\/strong\u003e.\u003c\/div\u003e\n\u003c\/details\u003e\n\u003cdetails open=\"\" class=\"hvx-faq\"\u003e\n\u003csummary\u003eHow much piping is supported?\u003c\/summary\u003e\n\u003cdiv style=\"margin-top: 8px;\"\u003eMaximum total piping length is \u003cstrong\u003e131 ft\u003c\/strong\u003e, with a maximum indoor\/outdoor height difference up to \u003cstrong\u003e49.21 ft\u003c\/strong\u003e.\u003c\/div\u003e\n\u003c\/details\u003e\n\u003cdetails open=\"\" class=\"hvx-faq\"\u003e\n\u003csummary\u003eDoes it come precharged with refrigerant?\u003c\/summary\u003e\n\u003cdiv style=\"margin-top: 8px;\"\u003eYes. The factory refrigerant precharge covers up to \u003cstrong\u003e50 ft\u003c\/strong\u003e of piping. Additional refrigerant may be required beyond that length.\u003c\/div\u003e\n\u003c\/details\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e","brand":"Cooper\u0026Hunter","offers":[{"title":"Default Title","offer_id":43086443479083,"sku":"CH-18MES-230VO","price":1121.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0625\/5647\/1339\/files\/REGULAR-24-36K.jpg?v=1771368617"},{"product_id":"cooper-hunter-multi-zone-r410a-outdoor-condenser-28-000-btu-2-33-ton","title":"Cooper\u0026Hunter Multi-Zone R410A Outdoor Condenser 28,000 BTU (2.33 Ton)","description":"\u003cstyle\u003e\n  :root{\n    --hvx-golden:#FAA819;\n    --hvx-slate:#262626;\n    --hvx-ivory:#F4F1E6;\n    --hvx-border:#e2e0d5;\n    --hvx-card-bg:#ffffff;\n  }\n\n  .hvx-desc{\n    font-family:\"Articulat CF\",system-ui,-apple-system,BlinkMacSystemFont,\"Segoe UI\",sans-serif;\n    color:var(--hvx-slate);\n    line-height:1.6;\n    background:var(--hvx-ivory);\n    padding:18px 18px 20px;\n    border-radius:16px;\n  }\n\n  .hvx-desc-header{\n    border-radius:14px;\n    padding:14px 16px;\n    background:linear-gradient(120deg,var(--hvx-golden),var(--hvx-slate));\n    color:#fff;\n    margin:0 0 16px;\n    box-shadow:0 10px 24px rgba(0,0,0,.22);\n    display:flex;\n    align-items:flex-start;\n    gap:12px;\n    flex-wrap:wrap;\n  }\n\n  .hvx-header-text{display:flex;flex-direction:column;gap:6px;min-width:260px}\n  .hvx-eyebrow{\n    font-size:11px;\n    letter-spacing:.14em;\n    text-transform:uppercase;\n    opacity:.9;\n  }\n  .hvx-title{\n    margin:0;\n    font-family:\"Anton\",\"Impact\",system-ui,-apple-system,BlinkMacSystemFont,\"Segoe UI\",sans-serif;\n    font-size:22px;\n    line-height:1.15;\n  }\n  .hvx-subtitle{\n    margin:0;\n    font-size:14px;\n    opacity:.95;\n  }\n\n  .hvx-desc-card{\n    border:1px solid var(--hvx-border);\n    border-radius:14px;\n    background:var(--hvx-card-bg);\n    padding:16px 18px 18px;\n    box-shadow:0 4px 12px rgba(0,0,0,.06);\n    margin:14px 0;\n  }\n\n  .hvx-section-title{\n    margin:0 0 10px;\n    font-family:\"Anton\",\"Impact\",system-ui,-apple-system,BlinkMacSystemFont,\"Segoe UI\",sans-serif;\n    font-size:17px;\n    letter-spacing:.08em;\n    text-transform:uppercase;\n    color:var(--hvx-slate);\n    display:inline-flex;\n    align-items:center;\n    gap:8px;\n  }\n  .hvx-section-title::after{\n    content:\"\";\n    flex:1;\n    height:2px;\n    border-radius:999px;\n    background:linear-gradient(90deg,var(--hvx-golden),transparent);\n    opacity:.9;\n  }\n\n  .hvx-cta{display:flex;flex-wrap:wrap;gap:10px;margin:10px 0 0}\n  .hvx-cta a{\n    display:inline-flex;\n    align-items:center;\n    gap:8px;\n    padding:10px 14px;\n    border-radius:12px;\n    border:1px solid var(--hvx-border);\n    background:#fff;\n    text-decoration:none;\n    color:var(--hvx-slate);\n    font-size:14px;\n    font-weight:700;\n  }\n  .hvx-cta a.primary{\n    background:var(--hvx-slate);\n    color:#fff;\n    border-color:transparent;\n  }\n\n  .hvx-badges{display:flex;flex-wrap:wrap;gap:8px;margin:10px 0 0}\n  .hvx-badge{\n    font-size:12px;\n    border:1px solid var(--hvx-border);\n    border-radius:999px;\n    padding:6px 10px;\n    background:#fff;\n    white-space:nowrap;\n  }\n\n  .hvx-kv{\n    display:grid;\n    grid-template-columns:repeat(4,minmax(160px,1fr));\n    gap:10px;\n    margin-top:10px;\n  }\n  .hvx-kv \u003e div{\n    border:1px solid var(--hvx-border);\n    background:#fff;\n    border-radius:12px;\n    padding:10px 12px;\n    text-align:center;\n  }\n  .hvx-kv strong{display:block}\n\n  .hvx-table{\n    width:100%;\n    border-collapse:collapse;\n    min-width:520px;\n    background:#fff;\n    border:1px solid var(--hvx-border);\n    border-radius:12px;\n    overflow:hidden;\n  }\n  .hvx-table th,.hvx-table td{\n    border-bottom:1px solid var(--hvx-border);\n    padding:10px 12px;\n    vertical-align:top;\n    font-size:14px;\n  }\n  .hvx-table th{ text-align:left; font-weight:800; background:#fff; }\n  .hvx-table tr:nth-child(even) td{ background:#fbfaf6; }\n  .hvx-table tr:last-child td{ border-bottom:none; }\n  .hvx-table-wrap{ overflow:auto; border-radius:12px; }\n\n  .hvx-link{color:var(--hvx-slate); text-decoration:underline; text-underline-offset:2px}\n  .hvx-link:hover{opacity:.85}\n\n  details.hvx-faq{\n    border:1px solid var(--hvx-border);\n    background:#fff;\n    border-radius:12px;\n    padding:10px 12px;\n    margin:8px 0;\n  }\n  details.hvx-faq summary{cursor:pointer;font-weight:800;}\n\n  @media(max-width:980px){\n    .hvx-kv{grid-template-columns:repeat(2,minmax(160px,1fr))}\n  }\n  @media(max-width:768px){\n    .hvx-desc{padding:14px 12px 16px;border-radius:12px}\n    .hvx-desc-header{padding:12px;border-radius:12px}\n    .hvx-title{font-size:19px}\n    .hvx-desc-card{padding:14px;margin:10px 0}\n  }\n\u003c\/style\u003e\n\n\u003cdiv class=\"hvx-desc\"\u003e\n  \u003cdiv class=\"hvx-desc-header\"\u003e\n    \u003cdiv class=\"hvx-header-text\"\u003e\n      \u003cdiv class=\"hvx-eyebrow\"\u003eCooper\u0026amp;Hunter ES Multi-Zone Outdoor Condenser • R410A • 230V\u003c\/div\u003e\n      \u003ch1 class=\"hvx-title\"\u003eCooper\u0026amp;Hunter 28,000 BTU Multi-Zone Outdoor Condenser (2.33 Ton) — CH-28MES-230VO\u003c\/h1\u003e\n      \u003cp class=\"hvx-subtitle\"\u003eHigh-efficiency ES series multi-zone condenser for pairing with multiple indoor unit styles, rated up to 24.6 SEER2 (system dependent).\u003c\/p\u003e\n    \u003c\/div\u003e\n  \u003c\/div\u003e\n\n  \u003cdiv class=\"hvx-cta\" aria-label=\"Contact options\"\u003e\n    \u003ca class=\"primary\" href=\"https:\/\/hvacsupplies.com\/pages\/contact\" rel=\"noopener\" title=\"Contact Us\" target=\"_blank\"\u003eCLICK HERE TO CONTACT US FOR CUSTOM QUOTES AND QUESTIONS\u003c\/a\u003e\n    \u003ca href=\"tel:+18005438933\" title=\"Call Us Now!\"\u003eCLICK TO CALL US 1-800-543-8933 FOR ANY QUESTIONS\u003c\/a\u003e\n  \u003c\/div\u003e\n\n  \u003cdiv class=\"hvx-desc-card\"\u003e\n    \u003ch2 class=\"hvx-section-title\"\u003eOverview\u003c\/h2\u003e\n    \u003cp style=\"margin:0;\"\u003e\n      The Cooper\u0026amp;Hunter \u003cstrong\u003eES condenser series\u003c\/strong\u003e includes Energy Star Certified outdoor units and offers both \u003cstrong\u003esingle\u003c\/strong\u003e and\n      \u003cstrong\u003emulti-zone\u003c\/strong\u003e configurations. ES outdoor units can be paired with multiple indoor styles—wall mounts, ceiling cassettes, slim ducts,\n      universal floor\/ceiling, mini floor consoles, and air handlers (match-up dependent)—to build a complete system that can reach up to\n      \u003cstrong\u003e24 SEER\u003c\/strong\u003e (system dependent).\n      \u003cbr\u003e\u003cbr\u003e\n      The \u003cstrong\u003eCH-28MES-230VO\u003c\/strong\u003e is a \u003cstrong\u003emulti-zone\u003c\/strong\u003e outdoor condenser rated at \u003cstrong\u003e28,000 BTU\u003c\/strong\u003e (2.33 ton) using\n      \u003cstrong\u003eR410A\u003c\/strong\u003e refrigerant on \u003cstrong\u003e208–230V\u003c\/strong\u003e power. It supports total piping up to \u003cstrong\u003e197 ft\u003c\/strong\u003e, factory precharge up to\n      \u003cstrong\u003e75 ft\u003c\/strong\u003e, and a maximum indoor\/outdoor height difference up to \u003cstrong\u003e49.21 ft\u003c\/strong\u003e. Ambient operating ranges are broad:\n      cooling down to \u003cstrong\u003e5°F\u003c\/strong\u003e and heating down to \u003cstrong\u003e-13°F\u003c\/strong\u003e.\n    \u003c\/p\u003e\n  \u003c\/div\u003e\n\n  \u003cdiv class=\"hvx-desc-card\"\u003e\n    \u003ch2 class=\"hvx-section-title\"\u003eHighlights\u003c\/h2\u003e\n\n    \u003cdiv class=\"hvx-badges\" role=\"list\"\u003e\n      \u003cspan class=\"hvx-badge\" role=\"listitem\"\u003e28,000 BTU (rated)\u003c\/span\u003e\n      \u003cspan class=\"hvx-badge\" role=\"listitem\"\u003eMulti-Zone\u003c\/span\u003e\n      \u003cspan class=\"hvx-badge\" role=\"listitem\"\u003eR410A\u003c\/span\u003e\n      \u003cspan class=\"hvx-badge\" role=\"listitem\"\u003eSEER2 24.6\u003c\/span\u003e\n      \u003cspan class=\"hvx-badge\" role=\"listitem\"\u003eEER2 12.7\u003c\/span\u003e\n      \u003cspan class=\"hvx-badge\" role=\"listitem\"\u003eHSPF2-4 9.3\u003c\/span\u003e\n      \u003cspan class=\"hvx-badge\" role=\"listitem\"\u003eHSPF2-5 7.1\u003c\/span\u003e\n      \u003cspan class=\"hvx-badge\" role=\"listitem\"\u003eMax Pipe 197 ft\u003c\/span\u003e\n      \u003cspan class=\"hvx-badge\" role=\"listitem\"\u003ePrecharge up to 75 ft\u003c\/span\u003e\n      \u003cspan class=\"hvx-badge\" role=\"listitem\"\u003eOutdoor Sound 61 dB(A)\u003c\/span\u003e\n      \u003cspan class=\"hvx-badge\" role=\"listitem\"\u003e5°F Cooling \/ -13°F Heating\u003c\/span\u003e\n      \u003cspan class=\"hvx-badge\" role=\"listitem\"\u003e3-Zone Ports\u003c\/span\u003e\n    \u003c\/div\u003e\n\n    \u003cul style=\"margin:12px 0 0; padding-left:18px;\"\u003e\n      \u003cli\u003e\n\u003cstrong\u003eMulti-zone flexibility:\u003c\/strong\u003e Designed to serve multiple indoor units (match-up dependent).\u003c\/li\u003e\n      \u003cli\u003e\n\u003cstrong\u003eHigh efficiency:\u003c\/strong\u003e Rated \u003cstrong\u003eSEER2 24.6\u003c\/strong\u003e and \u003cstrong\u003eEER2 12.7\u003c\/strong\u003e (system dependent).\u003c\/li\u003e\n      \u003cli\u003e\n\u003cstrong\u003eWide operating range:\u003c\/strong\u003e Cooling \u003cstrong\u003e5–122°F\u003c\/strong\u003e; heating \u003cstrong\u003e-13–75°F\u003c\/strong\u003e.\u003c\/li\u003e\n      \u003cli\u003e\n\u003cstrong\u003eCapacity modulation:\u003c\/strong\u003e Cooling range \u003cstrong\u003e9,838–30,438 BTU\/h\u003c\/strong\u003e; heating range \u003cstrong\u003e8,218–31,000 BTU\/h\u003c\/strong\u003e.\u003c\/li\u003e\n      \u003cli\u003e\n\u003cstrong\u003eInstallation parameters:\u003c\/strong\u003e Max total piping \u003cstrong\u003e197 ft\u003c\/strong\u003e and height difference up to \u003cstrong\u003e49.21 ft\u003c\/strong\u003e.\u003c\/li\u003e\n      \u003cli\u003e\n\u003cstrong\u003eService planning:\u003c\/strong\u003e Additional refrigerant charge guidance included for 1\/4\" and 3\/8\" liquid lines.\u003c\/li\u003e\n    \u003c\/ul\u003e\n\n    \u003cdiv class=\"hvx-kv\" role=\"list\" aria-label=\"At-a-glance\"\u003e\n      \u003cdiv role=\"listitem\"\u003e\n\u003cstrong\u003eModel\u003c\/strong\u003eCH-28MES-230VO\u003c\/div\u003e\n      \u003cdiv role=\"listitem\"\u003e\n\u003cstrong\u003eSystem Type\u003c\/strong\u003eMulti-Zone\u003c\/div\u003e\n      \u003cdiv role=\"listitem\"\u003e\n\u003cstrong\u003ePorts\u003c\/strong\u003e3 Zones (3× liq \/ 3× gas)\u003c\/div\u003e\n      \u003cdiv role=\"listitem\"\u003e\n\u003cstrong\u003ePower\u003c\/strong\u003e208–230V, 1Ph\u003c\/div\u003e\n    \u003c\/div\u003e\n  \u003c\/div\u003e\n\n  \u003cdiv class=\"hvx-desc-card\"\u003e\n    \u003ch2 class=\"hvx-section-title\"\u003eWhat's Included\u003c\/h2\u003e\n    \u003cul style=\"padding-left:18px; margin:8px 0;\"\u003e\n      \u003cli\u003eOutdoor condenser unit: \u003cstrong\u003eCH-28MES-230VO\u003c\/strong\u003e\n\u003c\/li\u003e\n    \u003c\/ul\u003e\n  \u003c\/div\u003e\n\n  \u003cdiv class=\"hvx-desc-card\"\u003e\n    \u003ch2 class=\"hvx-section-title\"\u003eOutdoor Specs\u003c\/h2\u003e\n    \u003cdiv class=\"hvx-table-wrap\"\u003e\n      \u003ctable class=\"hvx-table\" aria-label=\"Outdoor unit specifications\"\u003e\n        \u003cthead\u003e\n          \u003ctr\u003e\n\u003cth\u003eSpec\u003c\/th\u003e\n\u003cth\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\n        \u003c\/thead\u003e\n        \u003ctbody\u003e\n          \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCH-28MES-230VO\u003c\/td\u003e\n\u003c\/tr\u003e\n          \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRefrigerant Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eR410A\u003c\/td\u003e\n\u003c\/tr\u003e\n          \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSystem Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMulti-zone unit\u003c\/td\u003e\n\u003c\/tr\u003e\n          \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBTU Rated\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e28,000\u003c\/td\u003e\n\u003c\/tr\u003e\n          \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCooling Capacity (Min\/Max)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e28,000 (9,838–30,438) BTU\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n          \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eHeating Capacity (Min\/Max)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e28,000 (8,218–31,000) BTU\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n          \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSEER2 \/ EER2\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e24.6 \/ 12.7\u003c\/td\u003e\n\u003c\/tr\u003e\n          \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eHSPF2-4 \/ HSPF2-5\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e9.3 \/ 7.1\u003c\/td\u003e\n\u003c\/tr\u003e\n          \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCOP\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3.73\u003c\/td\u003e\n\u003c\/tr\u003e\n          \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower Source\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e208–230V, 1Ph, 60Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n          \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eVoltage Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e187–253 V\u003c\/td\u003e\n\u003c\/tr\u003e\n          \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMinimum Circuit Ampacity (MCA)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e24.5 A\u003c\/td\u003e\n\u003c\/tr\u003e\n          \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMax Fuse\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e30 A\u003c\/td\u003e\n\u003c\/tr\u003e\n          \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMax Pipe Length\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e197 ft\u003c\/td\u003e\n\u003c\/tr\u003e\n          \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMax Height Difference (Indoor↔Outdoor)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e49.21 ft\u003c\/td\u003e\n\u003c\/tr\u003e\n          \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRefrigerant Piping (Liquid \/ Gas)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3× 1\/4\" (liq) \/ 3× 3\/8\" (gas)\u003c\/td\u003e\n\u003c\/tr\u003e\n          \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRefrigerant Precharge\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eUp to 75 ft\u003c\/td\u003e\n\u003c\/tr\u003e\n          \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOutdoor Noise\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e61 dB(A)\u003c\/td\u003e\n\u003c\/tr\u003e\n          \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOutdoor Air Flow\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2,129.41\u003c\/td\u003e\n\u003c\/tr\u003e\n          \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAmbient Range (Cooling)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e5–122 °F\u003c\/td\u003e\n\u003c\/tr\u003e\n          \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAmbient Range (Heating)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-13–75 °F\u003c\/td\u003e\n\u003c\/tr\u003e\n          \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAdditional Charge (3\/8\" liquid)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.32\u003c\/td\u003e\n\u003c\/tr\u003e\n          \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAdditional Charge (1\/4\" liquid)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.16\u003c\/td\u003e\n\u003c\/tr\u003e\n          \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eUnit Dimensions (W×H×D)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e37.24 × 16.14 × 31.89 in\u003c\/td\u003e\n\u003c\/tr\u003e\n          \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eUnit Net \/ Gross Weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e139.77 \/ 150.57 lb\u003c\/td\u003e\n\u003c\/tr\u003e\n          \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePacking Dimensions (W×D×H)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e42.91 × 19.69 × 34.84\u003c\/td\u003e\n\u003c\/tr\u003e\n          \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDehumidification\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4.14 pints\/day\u003c\/td\u003e\n\u003c\/tr\u003e\n        \u003c\/tbody\u003e\n      \u003c\/table\u003e\n    \u003c\/div\u003e\n  \u003c\/div\u003e\n\n  \u003cdiv class=\"hvx-desc-card\"\u003e\n    \u003ch2 class=\"hvx-section-title\"\u003eVideos\u003c\/h2\u003e\n\n    \u003cdiv style=\"margin:8px 0 0;\"\u003e\n      \u003cdiv style=\"font-weight:800; margin:10px 0 6px;\"\u003eMini-split installation videos\u003c\/div\u003e\n      \u003cul style=\"padding-left:18px; margin:0;\"\u003e\n        \u003cli\u003e\u003ca class=\"hvx-link\" href=\"https:\/\/youtu.be\/Cxuiytm_CMo\" rel=\"noopener\" target=\"_blank\"\u003eHow to Install Multi Zone Mini Split System (Cooper\u0026amp;Hunter) 2020\u003c\/a\u003e\u003c\/li\u003e\n        \u003cli\u003e\u003ca class=\"hvx-link\" href=\"https:\/\/youtu.be\/EU4Jd6QYgFE\" rel=\"noopener\" target=\"_blank\"\u003eCooper\u0026amp;Hunter Outdoor Wall Mounting Bracket\u003c\/a\u003e\u003c\/li\u003e\n        \u003cli\u003e\u003ca class=\"hvx-link\" href=\"https:\/\/youtu.be\/JQkth-AM5CE\" rel=\"noopener\" target=\"_blank\"\u003eFull Installation of Mini Split Ductless Unit, Step by Step!\u003c\/a\u003e\u003c\/li\u003e\n      \u003c\/ul\u003e\n    \u003c\/div\u003e\n\n    \u003cdiv style=\"margin:12px 0 0;\"\u003e\n      \u003cdiv style=\"font-weight:800; margin:10px 0 6px;\"\u003eHow To \u0026amp; Instructional Videos\u003c\/div\u003e\n      \u003cul style=\"padding-left:18px; margin:0;\"\u003e\n        \u003cli\u003e\u003ca class=\"hvx-link\" href=\"https:\/\/youtu.be\/mEP87TQVS6g\" rel=\"noopener\" target=\"_blank\"\u003eHow to Change Main Board Cooper\u0026amp;Hunter Sophia Wall Mount\u003c\/a\u003e\u003c\/li\u003e\n        \u003cli\u003e\u003ca class=\"hvx-link\" href=\"https:\/\/youtu.be\/7mzwevkxw20\" rel=\"noopener\" target=\"_blank\"\u003eTop Tips from Cooper\u0026amp;Hunter Mini Split User Manual\u003c\/a\u003e\u003c\/li\u003e\n      \u003c\/ul\u003e\n    \u003c\/div\u003e\n\n    \u003cdiv style=\"margin:12px 0 0;\"\u003e\n      \u003cdiv style=\"font-weight:800; margin:10px 0 6px;\"\u003eProducts overview\u003c\/div\u003e\n      \u003cul style=\"padding-left:18px; margin:0;\"\u003e\n        \u003cli\u003e\u003ca class=\"hvx-link\" href=\"https:\/\/youtu.be\/0kUh03W9qS8\" rel=\"noopener\" target=\"_blank\"\u003eCooper\u0026amp;Hunter: Multi Zone AC for the Home\u003c\/a\u003e\u003c\/li\u003e\n        \u003cli\u003e\u003ca class=\"hvx-link\" href=\"https:\/\/youtu.be\/TCcju8Ii6L8\" rel=\"noopener\" target=\"_blank\"\u003eMulti-Zone Mini-Split System vs Central A\/C in Home (2019) Cooper\u0026amp;Hunter\u003c\/a\u003e\u003c\/li\u003e\n        \u003cli\u003e\u003ca class=\"hvx-link\" href=\"https:\/\/youtu.be\/k6CLIFdvVXk\" rel=\"noopener\" target=\"_blank\"\u003eCooper\u0026amp;Hunter Products at AHR Expo 2020 with Robot Millennia\u003c\/a\u003e\u003c\/li\u003e\n        \u003cli\u003e\u003ca class=\"hvx-link\" href=\"https:\/\/youtu.be\/2u0pa2jThCM\" rel=\"noopener\" target=\"_blank\"\u003eHVAC Installation Kit: 99.9% Copper Line Sets (Cooper\u0026amp;Hunter)\u003c\/a\u003e\u003c\/li\u003e\n        \u003cli\u003e\u003ca class=\"hvx-link\" href=\"https:\/\/youtu.be\/qCWu8HCNl3Q\" rel=\"noopener\" target=\"_blank\"\u003eMini Split Indoor Unit Types Explained\u003c\/a\u003e\u003c\/li\u003e\n      \u003c\/ul\u003e\n    \u003c\/div\u003e\n\n    \u003cdiv style=\"margin:12px 0 0;\"\u003e\n      \u003cdiv style=\"font-weight:800; margin:10px 0 6px;\"\u003eMini-Splits\u003c\/div\u003e\n      \u003cul style=\"padding-left:18px; margin:0;\"\u003e\n        \u003cli\u003e\u003ca class=\"hvx-link\" href=\"https:\/\/www.youtube.com\/watch?v=n00qcO3iIR0\" rel=\"noopener\" target=\"_blank\"\u003eCan You Use a Mini Split in EXTREME COLD? Heat Pump vs. Propane Cost Comparison with Thermal Camera\u003c\/a\u003e\u003c\/li\u003e\n        \u003cli\u003e\u003ca class=\"hvx-link\" href=\"https:\/\/www.youtube.com\/watch?v=5QgZqyFp334\" rel=\"noopener\" target=\"_blank\"\u003eWhere To Mount a Mini Split Indoor Wall Hung Unit\u003c\/a\u003e\u003c\/li\u003e\n        \u003cli\u003e\u003ca class=\"hvx-link\" href=\"https:\/\/www.youtube.com\/watch?v=hxYrOv5bV9Y\" rel=\"noopener\" target=\"_blank\"\u003eHow To Wall Mount a Mini Split Outdoor Condenser Unit\u003c\/a\u003e\u003c\/li\u003e\n        \u003cli\u003e\u003ca class=\"hvx-link\" href=\"https:\/\/www.youtube.com\/watch?v=3DHyShrGUXw\" rel=\"noopener\" target=\"_blank\"\u003eAre Mini Split Air Conditioners Worth It? - Top 5 Pros \u0026amp; Cons\u003c\/a\u003e\u003c\/li\u003e\n        \u003cli\u003e\u003ca class=\"hvx-link\" href=\"https:\/\/www.youtube.com\/watch?v=USU0xujHHL8\" rel=\"noopener\" target=\"_blank\"\u003eDoes a Wall Mounted MINISPLIT Need a CONDENSATE TRAP? Ductless vs Ducted Air Handlers!\u003c\/a\u003e\u003c\/li\u003e\n        \u003cli\u003e\u003ca class=\"hvx-link\" href=\"https:\/\/www.youtube.com\/watch?v=ATk1fx_N_qc\" rel=\"noopener\" target=\"_blank\"\u003eMINI SPLIT Parts Explained! Understand What They Do!\u003c\/a\u003e\u003c\/li\u003e\n        \u003cli\u003e\u003ca class=\"hvx-link\" href=\"https:\/\/www.youtube.com\/watch?v=-GHFRcvQwNA\" rel=\"noopener\" target=\"_blank\"\u003eMini Split Failure from Electrical Surges, High and Low Voltage! HOW TO SOLVE IT!\u003c\/a\u003e\u003c\/li\u003e\n        \u003cli\u003e\u003ca class=\"hvx-link\" href=\"https:\/\/www.youtube.com\/watch?v=ZNRlS2xOcVc\" rel=\"noopener\" target=\"_blank\"\u003eFull Installation of an Inverter Minisplit Heat Pump with Indoor Ceiling Cassette\u003c\/a\u003e\u003c\/li\u003e\n        \u003cli\u003e\u003ca class=\"hvx-link\" href=\"https:\/\/www.youtube.com\/watch?v=BxMwbC_2ow8\" rel=\"noopener\" target=\"_blank\"\u003eChecking the Refrigerant Charge on a Running R-410A Inverter MINI SPLIT Unit\u003c\/a\u003e\u003c\/li\u003e\n        \u003cli\u003e\u003ca class=\"hvx-link\" href=\"https:\/\/www.youtube.com\/watch?v=qCWu8HCNl3Q\" rel=\"noopener\" target=\"_blank\"\u003eMini Split Indoor Unit Types Explained! 5 Types- Applications, Connection Points, Mounting!\u003c\/a\u003e\u003c\/li\u003e\n      \u003c\/ul\u003e\n    \u003c\/div\u003e\n  \u003c\/div\u003e\n\n  \u003cdiv class=\"hvx-desc-card\"\u003e\n    \u003ch2 class=\"hvx-section-title\"\u003eDocuments \u0026amp; Downloads\u003c\/h2\u003e\n    \u003cul style=\"padding-left:18px; margin:8px 0;\"\u003e\n      \u003cli\u003e\u003ca class=\"hvx-link\" href=\"https:\/\/media.cooperandhunter.us\/3162\/CH-28MES-230VO-%28Ducted%29.pdf\" rel=\"noopener\" target=\"_blank\"\u003eSubmittal — CH-28MES-230VO (Ducted) (PDF)\u003c\/a\u003e\u003c\/li\u003e\n      \u003cli\u003e\u003ca class=\"hvx-link\" href=\"https:\/\/media.cooperandhunter.us\/3163\/CH-28MES-230VO-%28Non-ducted%29.pdf\" rel=\"noopener\" target=\"_blank\"\u003eSubmittal — CH-28MES-230VO (Non-Ducted) (PDF)\u003c\/a\u003e\u003c\/li\u003e\n\n      \u003cli\u003e\u003ca class=\"hvx-link\" href=\"https:\/\/media.cooperandhunter.us\/3755\/Multi-Zone-Leaflet-2024.pdf\" rel=\"noopener\" target=\"_blank\"\u003eMulti-Zone Series — Leaflet (2024) (PDF)\u003c\/a\u003e\u003c\/li\u003e\n      \u003cli\u003e\u003ca class=\"hvx-link\" href=\"https:\/\/media.cooperandhunter.us\/4433\/Installation-manual.pdf\" rel=\"noopener\" target=\"_blank\"\u003eInstallation Manual — Multi-Zone Outdoor (PDF)\u003c\/a\u003e\u003c\/li\u003e\n\n      \u003cli\u003e\u003ca class=\"hvx-link\" href=\"https:\/\/media.cooperandhunter.us\/3199\/MultiZone-Combination-Regular.pdf\" rel=\"noopener\" target=\"_blank\"\u003eMulti-Zone Combination — Regular (PDF)\u003c\/a\u003e\u003c\/li\u003e\n    \u003c\/ul\u003e\n  \u003c\/div\u003e\n\n  \u003cdiv class=\"hvx-desc-card\"\u003e\n    \u003ch2 class=\"hvx-section-title\"\u003eCertifications\u003c\/h2\u003e\n    \u003cul style=\"padding-left:18px; margin:8px 0;\"\u003e\n      \u003cli\u003eAHRI Ducted — \u003cstrong\u003e210799620\u003c\/strong\u003e (\u003ca class=\"hvx-link\" href=\"https:\/\/www.ahridirectory.org\/NewSearch?programId=41\u0026amp;searchTypeId=3\u0026amp;productTypeId=4\" rel=\"noopener\" target=\"_blank\"\u003eAHRI Directory\u003c\/a\u003e)\u003c\/li\u003e\n      \u003cli\u003eAHRI Non-Ducted — \u003cstrong\u003e210799619\u003c\/strong\u003e (\u003ca class=\"hvx-link\" href=\"https:\/\/www.ahridirectory.org\/NewSearch?programId=41\u0026amp;searchTypeId=3\u0026amp;productTypeId=4\" rel=\"noopener\" target=\"_blank\"\u003eAHRI Directory\u003c\/a\u003e)\u003c\/li\u003e\n      \u003cli\u003eAHRI Mixed — \u003cstrong\u003e210799621\u003c\/strong\u003e (\u003ca class=\"hvx-link\" href=\"https:\/\/www.ahridirectory.org\/NewSearch?programId=41\u0026amp;searchTypeId=3\u0026amp;productTypeId=4\" rel=\"noopener\" target=\"_blank\"\u003eAHRI Directory\u003c\/a\u003e)\u003c\/li\u003e\n    \u003c\/ul\u003e\n  \u003c\/div\u003e\n\n  \u003cdiv class=\"hvx-desc-card\"\u003e\n    \u003ch2 class=\"hvx-section-title\"\u003eImportant\u003c\/h2\u003e\n    \u003cp style=\"margin:0; font-size:14px;\"\u003e\n      Install with a licensed HVAC professional. This is a \u003cstrong\u003emulti-zone outdoor condenser\u003c\/strong\u003e intended to be matched with compatible indoor units.\n      Confirm match-ups, total connected indoor capacity, and piping design before ordering. Observe maximum total piping (\u003cstrong\u003e197 ft\u003c\/strong\u003e),\n      height limits (\u003cstrong\u003e49.21 ft\u003c\/strong\u003e), and required electrical protection (\u003cstrong\u003eMCA 24.5A\u003c\/strong\u003e, \u003cstrong\u003emax fuse 30A\u003c\/strong\u003e).\n      Refrigerant is \u003cstrong\u003eR410A\u003c\/strong\u003e with factory precharge up to \u003cstrong\u003e75 ft\u003c\/strong\u003e; additional charge may be required beyond that length.\n    \u003c\/p\u003e\n  \u003c\/div\u003e\n\n  \u003cdiv class=\"hvx-desc-card\"\u003e\n    \u003ch2 class=\"hvx-section-title\"\u003eFAQs\u003c\/h2\u003e\n\n    \u003cdetails class=\"hvx-faq\" open\u003e\n      \u003csummary\u003eIs this a single-zone or multi-zone outdoor unit?\u003c\/summary\u003e\n      \u003cdiv style=\"margin-top:8px;\"\u003eThis model is a \u003cstrong\u003emulti-zone\u003c\/strong\u003e outdoor condenser.\u003c\/div\u003e\n    \u003c\/details\u003e\n\n    \u003cdetails class=\"hvx-faq\" open\u003e\n      \u003csummary\u003eHow many indoor units can it connect to?\u003c\/summary\u003e\n      \u003cdiv style=\"margin-top:8px;\"\u003eThe piping spec lists \u003cstrong\u003e3 sets\u003c\/strong\u003e of connections (3× liquid and 3× gas), indicating support for up to \u003cstrong\u003ethree zones\u003c\/strong\u003e when matched correctly.\u003c\/div\u003e\n    \u003c\/details\u003e\n\n    \u003cdetails class=\"hvx-faq\" open\u003e\n      \u003csummary\u003eWhat are the operating temperature ranges?\u003c\/summary\u003e\n      \u003cdiv style=\"margin-top:8px;\"\u003eCooling ambient range is \u003cstrong\u003e5–122°F\u003c\/strong\u003e. Heating ambient range is \u003cstrong\u003e-13–75°F\u003c\/strong\u003e.\u003c\/div\u003e\n    \u003c\/details\u003e\n\n    \u003cdetails class=\"hvx-faq\" open\u003e\n      \u003csummary\u003eHow much piping is supported?\u003c\/summary\u003e\n      \u003cdiv style=\"margin-top:8px;\"\u003eMaximum total piping length is \u003cstrong\u003e197 ft\u003c\/strong\u003e, with a maximum indoor\/outdoor height difference up to \u003cstrong\u003e49.21 ft\u003c\/strong\u003e.\u003c\/div\u003e\n    \u003c\/details\u003e\n\n    \u003cdetails class=\"hvx-faq\" open\u003e\n      \u003csummary\u003eDoes it come precharged with refrigerant?\u003c\/summary\u003e\n      \u003cdiv style=\"margin-top:8px;\"\u003eYes. The factory refrigerant precharge covers up to \u003cstrong\u003e75 ft\u003c\/strong\u003e of piping. Additional refrigerant may be required beyond that length.\u003c\/div\u003e\n    \u003c\/details\u003e\n  \u003c\/div\u003e\n\u003c\/div\u003e\n","brand":"Cooper\u0026Hunter","offers":[{"title":"Default Title","offer_id":43086444101675,"sku":"CH-28MES-230VO","price":1519.0,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0625\/5647\/1339\/files\/REGULAR-24-36K.jpg?v=1771368617"},{"product_id":"cooper-hunter-multi-zone-r410a-outdoor-condenser-48-000-btu-4-ton","title":"Cooper\u0026Hunter Multi-Zone R410A Outdoor Condenser 48,000 BTU (4 Ton)","description":"\u003cstyle\u003e\n  :root{\n    --hvx-golden:#FAA819;\n    --hvx-slate:#262626;\n    --hvx-ivory:#F4F1E6;\n    --hvx-border:#e2e0d5;\n    --hvx-card-bg:#ffffff;\n  }\n\n  .hvx-desc{\n    font-family:\"Articulat CF\",system-ui,-apple-system,BlinkMacSystemFont,\"Segoe UI\",sans-serif;\n    color:var(--hvx-slate);\n    line-height:1.6;\n    background:var(--hvx-ivory);\n    padding:18px 18px 20px;\n    border-radius:16px;\n  }\n\n  .hvx-desc-header{\n    border-radius:14px;\n    padding:14px 16px;\n    background:linear-gradient(120deg,var(--hvx-golden),var(--hvx-slate));\n    color:#fff;\n    margin:0 0 16px;\n    box-shadow:0 10px 24px rgba(0,0,0,.22);\n    display:flex;\n    align-items:flex-start;\n    gap:12px;\n    flex-wrap:wrap;\n  }\n\n  .hvx-header-text{display:flex;flex-direction:column;gap:6px;min-width:260px}\n  .hvx-eyebrow{\n    font-size:11px;\n    letter-spacing:.14em;\n    text-transform:uppercase;\n    opacity:.9;\n  }\n  .hvx-title{\n    margin:0;\n    font-family:\"Anton\",\"Impact\",system-ui,-apple-system,BlinkMacSystemFont,\"Segoe UI\",sans-serif;\n    font-size:22px;\n    line-height:1.15;\n  }\n  .hvx-subtitle{\n    margin:0;\n    font-size:14px;\n    opacity:.95;\n  }\n\n  .hvx-desc-card{\n    border:1px solid var(--hvx-border);\n    border-radius:14px;\n    background:var(--hvx-card-bg);\n    padding:16px 18px 18px;\n    box-shadow:0 4px 12px rgba(0,0,0,.06);\n    margin:14px 0;\n  }\n\n  .hvx-section-title{\n    margin:0 0 10px;\n    font-family:\"Anton\",\"Impact\",system-ui,-apple-system,BlinkMacSystemFont,\"Segoe UI\",sans-serif;\n    font-size:17px;\n    letter-spacing:.08em;\n    text-transform:uppercase;\n    color:var(--hvx-slate);\n    display:inline-flex;\n    align-items:center;\n    gap:8px;\n  }\n  .hvx-section-title::after{\n    content:\"\";\n    flex:1;\n    height:2px;\n    border-radius:999px;\n    background:linear-gradient(90deg,var(--hvx-golden),transparent);\n    opacity:.9;\n  }\n\n  .hvx-cta{display:flex;flex-wrap:wrap;gap:10px;margin:10px 0 0}\n  .hvx-cta a{\n    display:inline-flex;\n    align-items:center;\n    gap:8px;\n    padding:10px 14px;\n    border-radius:12px;\n    border:1px solid var(--hvx-border);\n    background:#fff;\n    text-decoration:none;\n    color:var(--hvx-slate);\n    font-size:14px;\n    font-weight:700;\n  }\n  .hvx-cta a.primary{\n    background:var(--hvx-slate);\n    color:#fff;\n    border-color:transparent;\n  }\n\n  .hvx-badges{display:flex;flex-wrap:wrap;gap:8px;margin:10px 0 0}\n  .hvx-badge{\n    font-size:12px;\n    border:1px solid var(--hvx-border);\n    border-radius:999px;\n    padding:6px 10px;\n    background:#fff;\n    white-space:nowrap;\n  }\n\n  .hvx-kv{\n    display:grid;\n    grid-template-columns:repeat(4,minmax(160px,1fr));\n    gap:10px;\n    margin-top:10px;\n  }\n  .hvx-kv \u003e div{\n    border:1px solid var(--hvx-border);\n    background:#fff;\n    border-radius:12px;\n    padding:10px 12px;\n    text-align:center;\n  }\n  .hvx-kv strong{display:block}\n\n  .hvx-table{\n    width:100%;\n    border-collapse:collapse;\n    min-width:520px;\n    background:#fff;\n    border:1px solid var(--hvx-border);\n    border-radius:12px;\n    overflow:hidden;\n  }\n  .hvx-table th,.hvx-table td{\n    border-bottom:1px solid var(--hvx-border);\n    padding:10px 12px;\n    vertical-align:top;\n    font-size:14px;\n  }\n  .hvx-table th{ text-align:left; font-weight:800; background:#fff; }\n  .hvx-table tr:nth-child(even) td{ background:#fbfaf6; }\n  .hvx-table tr:last-child td{ border-bottom:none; }\n  .hvx-table-wrap{ overflow:auto; border-radius:12px; }\n\n  .hvx-link{color:var(--hvx-slate); text-decoration:underline; text-underline-offset:2px}\n  .hvx-link:hover{opacity:.85}\n\n  details.hvx-faq{\n    border:1px solid var(--hvx-border);\n    background:#fff;\n    border-radius:12px;\n    padding:10px 12px;\n    margin:8px 0;\n  }\n  details.hvx-faq summary{cursor:pointer;font-weight:800;}\n\n  @media(max-width:980px){\n    .hvx-kv{grid-template-columns:repeat(2,minmax(160px,1fr))}\n  }\n  @media(max-width:768px){\n    .hvx-desc{padding:14px 12px 16px;border-radius:12px}\n    .hvx-desc-header{padding:12px;border-radius:12px}\n    .hvx-title{font-size:19px}\n    .hvx-desc-card{padding:14px;margin:10px 0}\n  }\n\u003c\/style\u003e\n\n\u003cdiv class=\"hvx-desc\"\u003e\n  \u003cdiv class=\"hvx-desc-header\"\u003e\n    \u003cdiv class=\"hvx-header-text\"\u003e\n      \u003cdiv class=\"hvx-eyebrow\"\u003eCooper\u0026amp;Hunter ES Multi-Zone Outdoor Condenser • R410A • 230V\u003c\/div\u003e\n      \u003ch1 class=\"hvx-title\"\u003eCooper\u0026amp;Hunter 48,000 BTU Multi-Zone Outdoor Condenser (4 Ton) — CH-48MES-230VO\u003c\/h1\u003e\n      \u003cp class=\"hvx-subtitle\"\u003eHigh-capacity ES series multi-zone condenser for pairing with multiple indoor unit styles, rated up to 23.4 SEER2 (system dependent).\u003c\/p\u003e\n    \u003c\/div\u003e\n  \u003c\/div\u003e\n\n  \u003cdiv class=\"hvx-cta\" aria-label=\"Contact options\"\u003e\n    \u003ca class=\"primary\" href=\"https:\/\/hvacsupplies.com\/pages\/contact\" rel=\"noopener\" title=\"Contact Us\" target=\"_blank\"\u003eCLICK HERE TO CONTACT US FOR CUSTOM QUOTES AND QUESTIONS\u003c\/a\u003e\n    \u003ca href=\"tel:+18005438933\" title=\"Call Us Now!\"\u003eCLICK TO CALL US 1-800-543-8933 FOR ANY QUESTIONS\u003c\/a\u003e\n  \u003c\/div\u003e\n\n  \u003cdiv class=\"hvx-desc-card\"\u003e\n    \u003ch2 class=\"hvx-section-title\"\u003eOverview\u003c\/h2\u003e\n    \u003cp style=\"margin:0;\"\u003e\n      The Cooper\u0026amp;Hunter \u003cstrong\u003eES condenser series\u003c\/strong\u003e includes Energy Star Certified outdoor units and offers both \u003cstrong\u003esingle\u003c\/strong\u003e and\n      \u003cstrong\u003emulti-zone\u003c\/strong\u003e configurations. ES outdoor units can be paired with multiple indoor styles—wall mounts, ceiling cassettes, slim ducts,\n      universal floor\/ceiling, mini floor consoles, and air handlers (match-up dependent)—to build a complete system that can reach up to\n      \u003cstrong\u003e24 SEER\u003c\/strong\u003e (system dependent).\n      \u003cbr\u003e\u003cbr\u003e\n      The \u003cstrong\u003eCH-48MES-230VO\u003c\/strong\u003e is a \u003cstrong\u003emulti-zone\u003c\/strong\u003e outdoor condenser rated at \u003cstrong\u003e48,000 BTU\u003c\/strong\u003e (4 ton) using\n      \u003cstrong\u003eR410A\u003c\/strong\u003e refrigerant on \u003cstrong\u003e208–230V\u003c\/strong\u003e power. It supports total piping up to \u003cstrong\u003e262 ft\u003c\/strong\u003e, factory precharge up to\n      \u003cstrong\u003e125 ft\u003c\/strong\u003e, and a maximum indoor\/outdoor height difference up to \u003cstrong\u003e49.21 ft\u003c\/strong\u003e. Ambient operating ranges are broad:\n      cooling down to \u003cstrong\u003e5°F\u003c\/strong\u003e and heating down to \u003cstrong\u003e-13°F\u003c\/strong\u003e.\n    \u003c\/p\u003e\n  \u003c\/div\u003e\n\n  \u003cdiv class=\"hvx-desc-card\"\u003e\n    \u003ch2 class=\"hvx-section-title\"\u003eHighlights\u003c\/h2\u003e\n\n    \u003cdiv class=\"hvx-badges\" role=\"list\"\u003e\n      \u003cspan class=\"hvx-badge\" role=\"listitem\"\u003e48,000 BTU (rated)\u003c\/span\u003e\n      \u003cspan class=\"hvx-badge\" role=\"listitem\"\u003eMulti-Zone\u003c\/span\u003e\n      \u003cspan class=\"hvx-badge\" role=\"listitem\"\u003eR410A\u003c\/span\u003e\n      \u003cspan class=\"hvx-badge\" role=\"listitem\"\u003eSEER2 23.4\u003c\/span\u003e\n      \u003cspan class=\"hvx-badge\" role=\"listitem\"\u003eEER2 12.5\u003c\/span\u003e\n      \u003cspan class=\"hvx-badge\" role=\"listitem\"\u003eHSPF2-4 8.7\u003c\/span\u003e\n      \u003cspan class=\"hvx-badge\" role=\"listitem\"\u003eHSPF2-5 6.8\u003c\/span\u003e\n      \u003cspan class=\"hvx-badge\" role=\"listitem\"\u003eMax Pipe 262 ft\u003c\/span\u003e\n      \u003cspan class=\"hvx-badge\" role=\"listitem\"\u003ePrecharge up to 125 ft\u003c\/span\u003e\n      \u003cspan class=\"hvx-badge\" role=\"listitem\"\u003eOutdoor Sound 64 dB(A)\u003c\/span\u003e\n      \u003cspan class=\"hvx-badge\" role=\"listitem\"\u003e5°F Cooling \/ -13°F Heating\u003c\/span\u003e\n      \u003cspan class=\"hvx-badge\" role=\"listitem\"\u003eUp to 5 Zones (ports)\u003c\/span\u003e\n    \u003c\/div\u003e\n\n    \u003cul style=\"margin:12px 0 0; padding-left:18px;\"\u003e\n      \u003cli\u003e\n\u003cstrong\u003eHigh-capacity multi-zone:\u003c\/strong\u003e Rated \u003cstrong\u003e48,000 BTU\u003c\/strong\u003e for larger multi-zone applications (match-up dependent).\u003c\/li\u003e\n      \u003cli\u003e\n\u003cstrong\u003eHigh efficiency:\u003c\/strong\u003e Rated \u003cstrong\u003eSEER2 23.4\u003c\/strong\u003e and \u003cstrong\u003eEER2 12.5\u003c\/strong\u003e (system dependent).\u003c\/li\u003e\n      \u003cli\u003e\n\u003cstrong\u003eWide operating range:\u003c\/strong\u003e Cooling \u003cstrong\u003e5–122°F\u003c\/strong\u003e; heating \u003cstrong\u003e-13–75°F\u003c\/strong\u003e.\u003c\/li\u003e\n      \u003cli\u003e\n\u003cstrong\u003eCapacity modulation:\u003c\/strong\u003e Cooling range \u003cstrong\u003e19,000–50,000 BTU\/h\u003c\/strong\u003e; heating range \u003cstrong\u003e12,500–52,000 BTU\/h\u003c\/strong\u003e.\u003c\/li\u003e\n      \u003cli\u003e\n\u003cstrong\u003eInstallation parameters:\u003c\/strong\u003e Max total piping \u003cstrong\u003e262 ft\u003c\/strong\u003e and height difference up to \u003cstrong\u003e49.21 ft\u003c\/strong\u003e.\u003c\/li\u003e\n      \u003cli\u003e\n\u003cstrong\u003eBranch connections:\u003c\/strong\u003e Listed connections include \u003cstrong\u003e5\u003c\/strong\u003e liquid ports and mixed gas port sizes (3\/8\" and 1\/2\").\u003c\/li\u003e\n    \u003c\/ul\u003e\n\n    \u003cdiv class=\"hvx-kv\" role=\"list\" aria-label=\"At-a-glance\"\u003e\n      \u003cdiv role=\"listitem\"\u003e\n\u003cstrong\u003eModel\u003c\/strong\u003eCH-48MES-230VO\u003c\/div\u003e\n      \u003cdiv role=\"listitem\"\u003e\n\u003cstrong\u003eSystem Type\u003c\/strong\u003eMulti-Zone\u003c\/div\u003e\n      \u003cdiv role=\"listitem\"\u003e\n\u003cstrong\u003eConnections\u003c\/strong\u003e5× 1\/4\" liq \/ (3× 3\/8\" + 2× 1\/2\") gas\u003c\/div\u003e\n      \u003cdiv role=\"listitem\"\u003e\n\u003cstrong\u003ePower\u003c\/strong\u003e208–230V, 1Ph\u003c\/div\u003e\n    \u003c\/div\u003e\n  \u003c\/div\u003e\n\n  \u003cdiv class=\"hvx-desc-card\"\u003e\n    \u003ch2 class=\"hvx-section-title\"\u003eWhat's Included\u003c\/h2\u003e\n    \u003cul style=\"padding-left:18px; margin:8px 0;\"\u003e\n      \u003cli\u003eOutdoor condenser unit: \u003cstrong\u003eCH-48MES-230VO\u003c\/strong\u003e\n\u003c\/li\u003e\n    \u003c\/ul\u003e\n  \u003c\/div\u003e\n\n  \u003cdiv class=\"hvx-desc-card\"\u003e\n    \u003ch2 class=\"hvx-section-title\"\u003eOutdoor Specs\u003c\/h2\u003e\n    \u003cdiv class=\"hvx-table-wrap\"\u003e\n      \u003ctable class=\"hvx-table\" aria-label=\"Outdoor unit specifications\"\u003e\n        \u003cthead\u003e\n          \u003ctr\u003e\n\u003cth\u003eSpec\u003c\/th\u003e\n\u003cth\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\n        \u003c\/thead\u003e\n        \u003ctbody\u003e\n          \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCH-48MES-230VO\u003c\/td\u003e\n\u003c\/tr\u003e\n          \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRefrigerant Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eR410A\u003c\/td\u003e\n\u003c\/tr\u003e\n          \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSystem Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMulti-zone unit\u003c\/td\u003e\n\u003c\/tr\u003e\n          \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBTU Rated\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e48,000\u003c\/td\u003e\n\u003c\/tr\u003e\n          \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCooling Capacity (Min\/Max)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e48,000 (19,000–50,000) BTU\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n          \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eHeating Capacity (Min\/Max)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e48,000 (12,500–52,000) BTU\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n          \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSEER2 \/ EER2\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e23.4 \/ 12.5\u003c\/td\u003e\n\u003c\/tr\u003e\n          \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eHSPF2-4 \/ HSPF2-5\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e8.7 \/ 6.8\u003c\/td\u003e\n\u003c\/tr\u003e\n          \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCOP\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3.57\u003c\/td\u003e\n\u003c\/tr\u003e\n          \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower Source\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e208–230V, 1Ph, 60Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n          \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eVoltage Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e187–253 V\u003c\/td\u003e\n\u003c\/tr\u003e\n          \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMinimum Circuit Ampacity (MCA)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e40 A\u003c\/td\u003e\n\u003c\/tr\u003e\n          \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMax Fuse\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e60 A\u003c\/td\u003e\n\u003c\/tr\u003e\n          \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMax Pipe Length\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e262 ft\u003c\/td\u003e\n\u003c\/tr\u003e\n          \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMax Height Difference (Indoor↔Outdoor)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e49.21 ft\u003c\/td\u003e\n\u003c\/tr\u003e\n          \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRefrigerant Piping (Liquid \/ Gas)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e5× 1\/4\" (liq) \/ 3× 3\/8\" + 2× 1\/2\" (gas)\u003c\/td\u003e\n\u003c\/tr\u003e\n          \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRefrigerant Precharge\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eUp to 125 ft\u003c\/td\u003e\n\u003c\/tr\u003e\n          \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOutdoor Noise\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e64 dB(A)\u003c\/td\u003e\n\u003c\/tr\u003e\n          \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOutdoor Air Flow\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4,500\u003c\/td\u003e\n\u003c\/tr\u003e\n          \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAmbient Range (Cooling)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e5–122 °F\u003c\/td\u003e\n\u003c\/tr\u003e\n          \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAmbient Range (Heating)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-13–75 °F\u003c\/td\u003e\n\u003c\/tr\u003e\n          \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAdditional Charge (3\/8\" liquid)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.32\u003c\/td\u003e\n\u003c\/tr\u003e\n          \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAdditional Charge (1\/4\" liquid)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.16\u003c\/td\u003e\n\u003c\/tr\u003e\n          \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eUnit Dimensions (W×H×D)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e37.48 × 16.34 × 52.48 in\u003c\/td\u003e\n\u003c\/tr\u003e\n          \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eUnit Net \/ Gross Weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e225.53 \/ 256.62 lb\u003c\/td\u003e\n\u003c\/tr\u003e\n          \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePacking Dimensions (W×D×H)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e43.11 × 19.49 × 58.27\u003c\/td\u003e\n\u003c\/tr\u003e\n          \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDehumidification\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e10.69 pints\/day\u003c\/td\u003e\n\u003c\/tr\u003e\n        \u003c\/tbody\u003e\n      \u003c\/table\u003e\n    \u003c\/div\u003e\n  \u003c\/div\u003e\n\n  \u003cdiv class=\"hvx-desc-card\"\u003e\n    \u003ch2 class=\"hvx-section-title\"\u003eVideos\u003c\/h2\u003e\n\n    \u003cdiv style=\"margin:8px 0 0;\"\u003e\n      \u003cdiv style=\"font-weight:800; margin:10px 0 6px;\"\u003eMini-split installation videos\u003c\/div\u003e\n      \u003cul style=\"padding-left:18px; margin:0;\"\u003e\n        \u003cli\u003e\u003ca class=\"hvx-link\" href=\"https:\/\/youtu.be\/Cxuiytm_CMo\" rel=\"noopener\" target=\"_blank\"\u003eHow to Install Multi Zone Mini Split System (Cooper\u0026amp;Hunter) 2020\u003c\/a\u003e\u003c\/li\u003e\n        \u003cli\u003e\u003ca class=\"hvx-link\" href=\"https:\/\/youtu.be\/EU4Jd6QYgFE\" rel=\"noopener\" target=\"_blank\"\u003eCooper\u0026amp;Hunter Outdoor Wall Mounting Bracket\u003c\/a\u003e\u003c\/li\u003e\n        \u003cli\u003e\u003ca class=\"hvx-link\" href=\"https:\/\/youtu.be\/JQkth-AM5CE\" rel=\"noopener\" target=\"_blank\"\u003eFull Installation of Mini Split Ductless Unit, Step by Step!\u003c\/a\u003e\u003c\/li\u003e\n      \u003c\/ul\u003e\n    \u003c\/div\u003e\n\n    \u003cdiv style=\"margin:12px 0 0;\"\u003e\n      \u003cdiv style=\"font-weight:800; margin:10px 0 6px;\"\u003eHow To \u0026amp; Instructional Videos\u003c\/div\u003e\n      \u003cul style=\"padding-left:18px; margin:0;\"\u003e\n        \u003cli\u003e\u003ca class=\"hvx-link\" href=\"https:\/\/youtu.be\/7mzwevkxw20\" rel=\"noopener\" target=\"_blank\"\u003eTop Tips from Cooper\u0026amp;Hunter Mini Split User Manual\u003c\/a\u003e\u003c\/li\u003e\n      \u003c\/ul\u003e\n    \u003c\/div\u003e\n\n    \u003cdiv style=\"margin:12px 0 0;\"\u003e\n      \u003cdiv style=\"font-weight:800; margin:10px 0 6px;\"\u003eProducts overview\u003c\/div\u003e\n      \u003cul style=\"padding-left:18px; margin:0;\"\u003e\n        \u003cli\u003e\u003ca class=\"hvx-link\" href=\"https:\/\/youtu.be\/0kUh03W9qS8\" rel=\"noopener\" target=\"_blank\"\u003eCooper\u0026amp;Hunter: Multi Zone AC for the Home\u003c\/a\u003e\u003c\/li\u003e\n        \u003cli\u003e\u003ca class=\"hvx-link\" href=\"https:\/\/youtu.be\/TCcju8Ii6L8\" rel=\"noopener\" target=\"_blank\"\u003eMulti-Zone Mini-Split System vs Central A\/C in Home (2019) Cooper\u0026amp;Hunter\u003c\/a\u003e\u003c\/li\u003e\n        \u003cli\u003e\u003ca class=\"hvx-link\" href=\"https:\/\/youtu.be\/k6CLIFdvVXk\" rel=\"noopener\" target=\"_blank\"\u003eCooper\u0026amp;Hunter Products at AHR Expo 2020 with Robot Millennia\u003c\/a\u003e\u003c\/li\u003e\n        \u003cli\u003e\u003ca class=\"hvx-link\" href=\"https:\/\/youtu.be\/2u0pa2jThCM\" rel=\"noopener\" target=\"_blank\"\u003eHVAC Installation Kit: 99.9% Copper Line Sets (Cooper\u0026amp;Hunter)\u003c\/a\u003e\u003c\/li\u003e\n        \u003cli\u003e\u003ca class=\"hvx-link\" href=\"https:\/\/youtu.be\/qCWu8HCNl3Q\" rel=\"noopener\" target=\"_blank\"\u003eMini Split Indoor Unit Types Explained\u003c\/a\u003e\u003c\/li\u003e\n      \u003c\/ul\u003e\n    \u003c\/div\u003e\n\n    \u003cdiv style=\"margin:12px 0 0;\"\u003e\n      \u003cdiv style=\"font-weight:800; margin:10px 0 6px;\"\u003eMini-Splits\u003c\/div\u003e\n      \u003cul style=\"padding-left:18px; margin:0;\"\u003e\n        \u003cli\u003e\u003ca class=\"hvx-link\" href=\"https:\/\/www.youtube.com\/watch?v=n00qcO3iIR0\" rel=\"noopener\" target=\"_blank\"\u003eCan You Use a Mini Split in EXTREME COLD? Heat Pump vs. Propane Cost Comparison with Thermal Camera\u003c\/a\u003e\u003c\/li\u003e\n        \u003cli\u003e\u003ca class=\"hvx-link\" href=\"https:\/\/www.youtube.com\/watch?v=5QgZqyFp334\" rel=\"noopener\" target=\"_blank\"\u003eWhere To Mount a Mini Split Indoor Wall Hung Unit\u003c\/a\u003e\u003c\/li\u003e\n        \u003cli\u003e\u003ca class=\"hvx-link\" href=\"https:\/\/www.youtube.com\/watch?v=hxYrOv5bV9Y\" rel=\"noopener\" target=\"_blank\"\u003eHow To Wall Mount a Mini Split Outdoor Condenser Unit\u003c\/a\u003e\u003c\/li\u003e\n        \u003cli\u003e\u003ca class=\"hvx-link\" href=\"https:\/\/www.youtube.com\/watch?v=3DHyShrGUXw\" rel=\"noopener\" target=\"_blank\"\u003eAre Mini Split Air Conditioners Worth It? - Top 5 Pros \u0026amp; Cons\u003c\/a\u003e\u003c\/li\u003e\n        \u003cli\u003e\u003ca class=\"hvx-link\" href=\"https:\/\/www.youtube.com\/watch?v=USU0xujHHL8\" rel=\"noopener\" target=\"_blank\"\u003eDoes a Wall Mounted MINISPLIT Need a CONDENSATE TRAP? Ductless vs Ducted Air Handlers!\u003c\/a\u003e\u003c\/li\u003e\n        \u003cli\u003e\u003ca class=\"hvx-link\" href=\"https:\/\/www.youtube.com\/watch?v=ATk1fx_N_qc\" rel=\"noopener\" target=\"_blank\"\u003eMINI SPLIT Parts Explained! Understand What They Do!\u003c\/a\u003e\u003c\/li\u003e\n        \u003cli\u003e\u003ca class=\"hvx-link\" href=\"https:\/\/www.youtube.com\/watch?v=-GHFRcvQwNA\" rel=\"noopener\" target=\"_blank\"\u003eMini Split Failure from Electrical Surges, High and Low Voltage! HOW TO SOLVE IT!\u003c\/a\u003e\u003c\/li\u003e\n        \u003cli\u003e\u003ca class=\"hvx-link\" href=\"https:\/\/www.youtube.com\/watch?v=ZNRlS2xOcVc\" rel=\"noopener\" target=\"_blank\"\u003eFull Installation of an Inverter Minisplit Heat Pump with Indoor Ceiling Cassette\u003c\/a\u003e\u003c\/li\u003e\n        \u003cli\u003e\u003ca class=\"hvx-link\" href=\"https:\/\/www.youtube.com\/watch?v=BxMwbC_2ow8\" rel=\"noopener\" target=\"_blank\"\u003eChecking the Refrigerant Charge on a Running R-410A Inverter MINI SPLIT Unit\u003c\/a\u003e\u003c\/li\u003e\n        \u003cli\u003e\u003ca class=\"hvx-link\" href=\"https:\/\/www.youtube.com\/watch?v=qCWu8HCNl3Q\" rel=\"noopener\" target=\"_blank\"\u003eMini Split Indoor Unit Types Explained! 5 Types- Applications, Connection Points, Mounting!\u003c\/a\u003e\u003c\/li\u003e\n      \u003c\/ul\u003e\n    \u003c\/div\u003e\n  \u003c\/div\u003e\n\n  \u003cdiv class=\"hvx-desc-card\"\u003e\n    \u003ch2 class=\"hvx-section-title\"\u003eDocuments \u0026amp; Downloads\u003c\/h2\u003e\n    \u003cul style=\"padding-left:18px; margin:8px 0;\"\u003e\n      \u003cli\u003e\u003ca class=\"hvx-link\" href=\"https:\/\/media.cooperandhunter.us\/3166\/CH-48MES-230VO-%28Ducted%29.pdf\" rel=\"noopener\" target=\"_blank\"\u003eSubmittal — CH-48MES-230VO (Ducted) (PDF)\u003c\/a\u003e\u003c\/li\u003e\n      \u003cli\u003e\u003ca class=\"hvx-link\" href=\"https:\/\/media.cooperandhunter.us\/3167\/CH-48MES-230VO-%28Non-ducted%29.pdf\" rel=\"noopener\" target=\"_blank\"\u003eSubmittal — CH-48MES-230VO (Non-Ducted) (PDF)\u003c\/a\u003e\u003c\/li\u003e\n\n      \u003cli\u003e\u003ca class=\"hvx-link\" href=\"https:\/\/media.cooperandhunter.us\/3755\/Multi-Zone-Leaflet-2024.pdf\" rel=\"noopener\" target=\"_blank\"\u003eMulti-Zone Series — Leaflet (2024) (PDF)\u003c\/a\u003e\u003c\/li\u003e\n      \u003cli\u003e\u003ca class=\"hvx-link\" href=\"https:\/\/media.cooperandhunter.us\/4433\/Installation-manual.pdf\" rel=\"noopener\" target=\"_blank\"\u003eInstallation Manual — Multi-Zone Outdoor (PDF)\u003c\/a\u003e\u003c\/li\u003e\n\n      \u003cli\u003e\u003ca class=\"hvx-link\" href=\"https:\/\/media.cooperandhunter.us\/3199\/MultiZone-Combination-Regular.pdf\" rel=\"noopener\" target=\"_blank\"\u003eMulti-Zone Combination — Regular (PDF)\u003c\/a\u003e\u003c\/li\u003e\n    \u003c\/ul\u003e\n  \u003c\/div\u003e\n\n  \u003cdiv class=\"hvx-desc-card\"\u003e\n    \u003ch2 class=\"hvx-section-title\"\u003eCertifications\u003c\/h2\u003e\n    \u003cul style=\"padding-left:18px; margin:8px 0;\"\u003e\n      \u003cli\u003eAHRI Ducted — \u003cstrong\u003e210799626\u003c\/strong\u003e (\u003ca class=\"hvx-link\" href=\"https:\/\/www.ahridirectory.org\/NewSearch?programId=41\u0026amp;searchTypeId=3\u0026amp;productTypeId=4\" rel=\"noopener\" target=\"_blank\"\u003eAHRI Directory\u003c\/a\u003e)\u003c\/li\u003e\n      \u003cli\u003eAHRI Non-Ducted — \u003cstrong\u003e210799625\u003c\/strong\u003e (\u003ca class=\"hvx-link\" href=\"https:\/\/www.ahridirectory.org\/NewSearch?programId=41\u0026amp;searchTypeId=3\u0026amp;productTypeId=4\" rel=\"noopener\" target=\"_blank\"\u003eAHRI Directory\u003c\/a\u003e)\u003c\/li\u003e\n      \u003cli\u003eAHRI Mixed — \u003cstrong\u003e210799627\u003c\/strong\u003e (\u003ca class=\"hvx-link\" href=\"https:\/\/www.ahridirectory.org\/NewSearch?programId=41\u0026amp;searchTypeId=3\u0026amp;productTypeId=4\" rel=\"noopener\" target=\"_blank\"\u003eAHRI Directory\u003c\/a\u003e)\u003c\/li\u003e\n    \u003c\/ul\u003e\n  \u003c\/div\u003e\n\n  \u003cdiv class=\"hvx-desc-card\"\u003e\n    \u003ch2 class=\"hvx-section-title\"\u003eImportant\u003c\/h2\u003e\n    \u003cp style=\"margin:0; font-size:14px;\"\u003e\n      Install with a licensed HVAC professional. This is a \u003cstrong\u003emulti-zone outdoor condenser\u003c\/strong\u003e intended to be matched with compatible indoor units.\n      Confirm match-ups, total connected indoor capacity, and piping design before ordering. Observe maximum total piping (\u003cstrong\u003e262 ft\u003c\/strong\u003e),\n      height limits (\u003cstrong\u003e49.21 ft\u003c\/strong\u003e), and required electrical protection (\u003cstrong\u003eMCA 40A\u003c\/strong\u003e, \u003cstrong\u003emax fuse 60A\u003c\/strong\u003e).\n      Refrigerant is \u003cstrong\u003eR410A\u003c\/strong\u003e with factory precharge up to \u003cstrong\u003e125 ft\u003c\/strong\u003e; additional charge may be required beyond that length.\n    \u003c\/p\u003e\n  \u003c\/div\u003e\n\n  \u003cdiv class=\"hvx-desc-card\"\u003e\n    \u003ch2 class=\"hvx-section-title\"\u003eFAQs\u003c\/h2\u003e\n\n    \u003cdetails class=\"hvx-faq\" open\u003e\n      \u003csummary\u003eIs this a single-zone or multi-zone outdoor unit?\u003c\/summary\u003e\n      \u003cdiv style=\"margin-top:8px;\"\u003eThis model is a \u003cstrong\u003emulti-zone\u003c\/strong\u003e outdoor condenser.\u003c\/div\u003e\n    \u003c\/details\u003e\n\n    \u003cdetails class=\"hvx-faq\" open\u003e\n      \u003csummary\u003eHow many indoor units can it connect to?\u003c\/summary\u003e\n      \u003cdiv style=\"margin-top:8px;\"\u003eThe piping spec lists \u003cstrong\u003e5\u003c\/strong\u003e liquid connections and gas connections split between \u003cstrong\u003e3\/8\"\u003c\/strong\u003e and \u003cstrong\u003e1\/2\"\u003c\/strong\u003e, indicating support for up to \u003cstrong\u003efive zones\u003c\/strong\u003e when matched correctly.\u003c\/div\u003e\n    \u003c\/details\u003e\n\n    \u003cdetails class=\"hvx-faq\" open\u003e\n      \u003csummary\u003eWhat are the operating temperature ranges?\u003c\/summary\u003e\n      \u003cdiv style=\"margin-top:8px;\"\u003eCooling ambient range is \u003cstrong\u003e5–122°F\u003c\/strong\u003e. Heating ambient range is \u003cstrong\u003e-13–75°F\u003c\/strong\u003e.\u003c\/div\u003e\n    \u003c\/details\u003e\n\n    \u003cdetails class=\"hvx-faq\" open\u003e\n      \u003csummary\u003eHow much piping is supported?\u003c\/summary\u003e\n      \u003cdiv style=\"margin-top:8px;\"\u003eMaximum total piping length is \u003cstrong\u003e262 ft\u003c\/strong\u003e, with a maximum indoor\/outdoor height difference up to \u003cstrong\u003e49.21 ft\u003c\/strong\u003e.\u003c\/div\u003e\n    \u003c\/details\u003e\n\n    \u003cdetails class=\"hvx-faq\" open\u003e\n      \u003csummary\u003eDoes it come precharged with refrigerant?\u003c\/summary\u003e\n      \u003cdiv style=\"margin-top:8px;\"\u003eYes. The factory refrigerant precharge covers up to \u003cstrong\u003e125 ft\u003c\/strong\u003e of piping. Additional refrigerant may be required beyond that length.\u003c\/div\u003e\n    \u003c\/details\u003e\n  \u003c\/div\u003e\n\u003c\/div\u003e\n","brand":"Cooper\u0026Hunter","offers":[{"title":"Default Title","offer_id":43086444462123,"sku":"CH-48MES-230VO","price":2787.0,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0625\/5647\/1339\/files\/48000_BTU.webp?v=1771368864"},{"product_id":"cooper-hunter-multi-zone-r410a-outdoor-condenser-55-000-btu-4-58-ton","title":"Cooper\u0026Hunter Multi-Zone R410A Outdoor Condenser 55,000 BTU (4.58 Ton)","description":"\u003cstyle\u003e\n  :root{\n    --hvx-golden:#FAA819;\n    --hvx-slate:#262626;\n    --hvx-ivory:#F4F1E6;\n    --hvx-border:#e2e0d5;\n    --hvx-card-bg:#ffffff;\n  }\n\n  .hvx-desc{\n    font-family:\"Articulat CF\",system-ui,-apple-system,BlinkMacSystemFont,\"Segoe UI\",sans-serif;\n    color:var(--hvx-slate);\n    line-height:1.6;\n    background:var(--hvx-ivory);\n    padding:18px 18px 20px;\n    border-radius:16px;\n  }\n\n  .hvx-desc-header{\n    border-radius:14px;\n    padding:14px 16px;\n    background:linear-gradient(120deg,var(--hvx-golden),var(--hvx-slate));\n    color:#fff;\n    margin:0 0 16px;\n    box-shadow:0 10px 24px rgba(0,0,0,.22);\n    display:flex;\n    align-items:flex-start;\n    gap:12px;\n    flex-wrap:wrap;\n  }\n\n  .hvx-header-text{display:flex;flex-direction:column;gap:6px;min-width:260px}\n  .hvx-eyebrow{\n    font-size:11px;\n    letter-spacing:.14em;\n    text-transform:uppercase;\n    opacity:.9;\n  }\n  .hvx-title{\n    margin:0;\n    font-family:\"Anton\",\"Impact\",system-ui,-apple-system,BlinkMacSystemFont,\"Segoe UI\",sans-serif;\n    font-size:22px;\n    line-height:1.15;\n  }\n  .hvx-subtitle{\n    margin:0;\n    font-size:14px;\n    opacity:.95;\n  }\n\n  .hvx-desc-card{\n    border:1px solid var(--hvx-border);\n    border-radius:14px;\n    background:var(--hvx-card-bg);\n    padding:16px 18px 18px;\n    box-shadow:0 4px 12px rgba(0,0,0,.06);\n    margin:14px 0;\n  }\n\n  .hvx-section-title{\n    margin:0 0 10px;\n    font-family:\"Anton\",\"Impact\",system-ui,-apple-system,BlinkMacSystemFont,\"Segoe UI\",sans-serif;\n    font-size:17px;\n    letter-spacing:.08em;\n    text-transform:uppercase;\n    color:var(--hvx-slate);\n    display:inline-flex;\n    align-items:center;\n    gap:8px;\n  }\n  .hvx-section-title::after{\n    content:\"\";\n    flex:1;\n    height:2px;\n    border-radius:999px;\n    background:linear-gradient(90deg,var(--hvx-golden),transparent);\n    opacity:.9;\n  }\n\n  .hvx-cta{display:flex;flex-wrap:wrap;gap:10px;margin:10px 0 0}\n  .hvx-cta a{\n    display:inline-flex;\n    align-items:center;\n    gap:8px;\n    padding:10px 14px;\n    border-radius:12px;\n    border:1px solid var(--hvx-border);\n    background:#fff;\n    text-decoration:none;\n    color:var(--hvx-slate);\n    font-size:14px;\n    font-weight:700;\n  }\n  .hvx-cta a.primary{\n    background:var(--hvx-slate);\n    color:#fff;\n    border-color:transparent;\n  }\n\n  .hvx-badges{display:flex;flex-wrap:wrap;gap:8px;margin:10px 0 0}\n  .hvx-badge{\n    font-size:12px;\n    border:1px solid var(--hvx-border);\n    border-radius:999px;\n    padding:6px 10px;\n    background:#fff;\n    white-space:nowrap;\n  }\n\n  .hvx-kv{\n    display:grid;\n    grid-template-columns:repeat(4,minmax(160px,1fr));\n    gap:10px;\n    margin-top:10px;\n  }\n  .hvx-kv \u003e div{\n    border:1px solid var(--hvx-border);\n    background:#fff;\n    border-radius:12px;\n    padding:10px 12px;\n    text-align:center;\n  }\n  .hvx-kv strong{display:block}\n\n  .hvx-table{\n    width:100%;\n    border-collapse:collapse;\n    min-width:520px;\n    background:#fff;\n    border:1px solid var(--hvx-border);\n    border-radius:12px;\n    overflow:hidden;\n  }\n  .hvx-table th,.hvx-table td{\n    border-bottom:1px solid var(--hvx-border);\n    padding:10px 12px;\n    vertical-align:top;\n    font-size:14px;\n  }\n  .hvx-table th{ text-align:left; font-weight:800; background:#fff; }\n  .hvx-table tr:nth-child(even) td{ background:#fbfaf6; }\n  .hvx-table tr:last-child td{ border-bottom:none; }\n  .hvx-table-wrap{ overflow:auto; border-radius:12px; }\n\n  .hvx-link{color:var(--hvx-slate); text-decoration:underline; text-underline-offset:2px}\n  .hvx-link:hover{opacity:.85}\n\n  details.hvx-faq{\n    border:1px solid var(--hvx-border);\n    background:#fff;\n    border-radius:12px;\n    padding:10px 12px;\n    margin:8px 0;\n  }\n  details.hvx-faq summary{cursor:pointer;font-weight:800;}\n\n  @media(max-width:980px){\n    .hvx-kv{grid-template-columns:repeat(2,minmax(160px,1fr))}\n  }\n  @media(max-width:768px){\n    .hvx-desc{padding:14px 12px 16px;border-radius:12px}\n    .hvx-desc-header{padding:12px;border-radius:12px}\n    .hvx-title{font-size:19px}\n    .hvx-desc-card{padding:14px;margin:10px 0}\n  }\n\u003c\/style\u003e\n\u003cdiv class=\"hvx-desc\"\u003e\n\u003cdiv class=\"hvx-desc-header\"\u003e\n\u003cdiv class=\"hvx-header-text\"\u003e\n\u003cdiv class=\"hvx-eyebrow\"\u003eCooper\u0026amp;Hunter ES Multi-Zone Outdoor Condenser • R410A • 230V\u003c\/div\u003e\n\u003ch1 class=\"hvx-title\"\u003eCooper\u0026amp;Hunter 55,000 BTU Multi-Zone Outdoor Condenser (4.58 Ton) — CH-55MES-230VO\u003c\/h1\u003e\n\u003cp class=\"hvx-subtitle\"\u003eHigh-capacity ES series multi-zone condenser for pairing with multiple indoor unit styles, rated up to 21.3 SEER2 (system dependent).\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv aria-label=\"Contact options\" class=\"hvx-cta\"\u003e\n\u003ca title=\"Contact Us\" rel=\"noopener\" href=\"https:\/\/hvacsupplies.com\/pages\/contact\" class=\"primary\" target=\"_blank\"\u003eCLICK HERE TO CONTACT US FOR CUSTOM QUOTES AND QUESTIONS\u003c\/a\u003e \u003ca title=\"Call Us Now!\" href=\"tel:+18005438933\"\u003eCLICK TO CALL US 1-800-543-8933 FOR ANY QUESTIONS\u003c\/a\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"hvx-desc-card\"\u003e\n\u003ch2 class=\"hvx-section-title\"\u003eOverview\u003c\/h2\u003e\n\u003cp style=\"margin: 0;\"\u003eThe Cooper\u0026amp;Hunter \u003cstrong\u003eES condenser series\u003c\/strong\u003e includes Energy Star Certified outdoor units and offers both \u003cstrong\u003esingle\u003c\/strong\u003e and \u003cstrong\u003emulti-zone\u003c\/strong\u003e configurations. ES outdoor units can be paired with multiple indoor styles—wall mounts, ceiling cassettes, slim ducts, universal floor\/ceiling, mini floor consoles, and air handlers (match-up dependent)—to build a complete system that can reach up to \u003cstrong\u003e24 SEER\u003c\/strong\u003e (system dependent). \u003cbr\u003e\u003cbr\u003eThe \u003cstrong\u003eCH-55MES-230VO\u003c\/strong\u003e is a \u003cstrong\u003emulti-zone\u003c\/strong\u003e outdoor condenser rated at \u003cstrong\u003e55,000 BTU\u003c\/strong\u003e (4.58 ton) using \u003cstrong\u003eR410A\u003c\/strong\u003e refrigerant on \u003cstrong\u003e208–230V\u003c\/strong\u003e power. It supports total piping up to \u003cstrong\u003e262 ft\u003c\/strong\u003e, factory precharge up to \u003cstrong\u003e125 ft\u003c\/strong\u003e, and a maximum indoor\/outdoor height difference up to \u003cstrong\u003e49.21 ft\u003c\/strong\u003e. Ambient operating ranges are broad: cooling down to \u003cstrong\u003e5°F\u003c\/strong\u003e and heating down to \u003cstrong\u003e-13°F\u003c\/strong\u003e.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"hvx-desc-card\"\u003e\n\u003ch2 class=\"hvx-section-title\"\u003eHighlights\u003c\/h2\u003e\n\u003cdiv role=\"list\" class=\"hvx-badges\"\u003e\n\u003cspan role=\"listitem\" class=\"hvx-badge\"\u003e55,000 BTU (rated)\u003c\/span\u003e \u003cspan role=\"listitem\" class=\"hvx-badge\"\u003eMulti-Zone\u003c\/span\u003e \u003cspan role=\"listitem\" class=\"hvx-badge\"\u003eR410A\u003c\/span\u003e \u003cspan role=\"listitem\" class=\"hvx-badge\"\u003eSEER2 21.3\u003c\/span\u003e \u003cspan role=\"listitem\" class=\"hvx-badge\"\u003eEER2 10.5\u003c\/span\u003e \u003cspan role=\"listitem\" class=\"hvx-badge\"\u003eHSPF2-4 9.1\u003c\/span\u003e \u003cspan role=\"listitem\" class=\"hvx-badge\"\u003eHSPF2-5 6.8\u003c\/span\u003e \u003cspan role=\"listitem\" class=\"hvx-badge\"\u003eMax Pipe 262 ft\u003c\/span\u003e \u003cspan role=\"listitem\" class=\"hvx-badge\"\u003ePrecharge up to 125 ft\u003c\/span\u003e \u003cspan role=\"listitem\" class=\"hvx-badge\"\u003eOutdoor Sound 62 dB(A)\u003c\/span\u003e \u003cspan role=\"listitem\" class=\"hvx-badge\"\u003e5°F Cooling \/ -13°F Heating\u003c\/span\u003e \u003cspan role=\"listitem\" class=\"hvx-badge\"\u003eUp to 5 Zones (ports)\u003c\/span\u003e\n\u003c\/div\u003e\n\u003cul style=\"margin: 12px 0 0; padding-left: 18px;\"\u003e\n\u003cli\u003e\n\u003cstrong\u003eHigh-capacity multi-zone:\u003c\/strong\u003e Rated \u003cstrong\u003e55,000 BTU\u003c\/strong\u003e for larger multi-zone applications (match-up dependent).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEfficiency:\u003c\/strong\u003e Rated \u003cstrong\u003eSEER2 21.3\u003c\/strong\u003e and \u003cstrong\u003eEER2 10.5\u003c\/strong\u003e (system dependent).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWide operating range:\u003c\/strong\u003e Cooling \u003cstrong\u003e5–122°F\u003c\/strong\u003e; heating \u003cstrong\u003e-13–75°F\u003c\/strong\u003e.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCapacity modulation:\u003c\/strong\u003e Cooling range \u003cstrong\u003e19,000–57,300 BTU\/h\u003c\/strong\u003e; heating range \u003cstrong\u003e12,500–60,000 BTU\/h\u003c\/strong\u003e.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInstallation parameters:\u003c\/strong\u003e Max total piping \u003cstrong\u003e262 ft\u003c\/strong\u003e and height difference up to \u003cstrong\u003e49.21 ft\u003c\/strong\u003e.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBranch connections:\u003c\/strong\u003e Listed connections include \u003cstrong\u003e5\u003c\/strong\u003e liquid ports and mixed gas port sizes (3\/8\" and 1\/2\").\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cdiv aria-label=\"At-a-glance\" role=\"list\" class=\"hvx-kv\"\u003e\n\u003cdiv role=\"listitem\"\u003e\n\u003cstrong\u003eModel\u003c\/strong\u003eCH-55MES-230VO\u003c\/div\u003e\n\u003cdiv role=\"listitem\"\u003e\n\u003cstrong\u003eSystem Type\u003c\/strong\u003eMulti-Zone\u003c\/div\u003e\n\u003cdiv role=\"listitem\"\u003e\n\u003cstrong\u003eConnections\u003c\/strong\u003e5× 1\/4\" liq \/ (3× 3\/8\" + 2× 1\/2\") gas\u003c\/div\u003e\n\u003cdiv role=\"listitem\"\u003e\n\u003cstrong\u003ePower\u003c\/strong\u003e208–230V, 1Ph\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"hvx-desc-card\"\u003e\n\u003ch2 class=\"hvx-section-title\"\u003eWhat's Included\u003c\/h2\u003e\n\u003cul style=\"padding-left: 18px; margin: 8px 0;\"\u003e\n\u003cli\u003eOutdoor condenser unit: \u003cstrong\u003eCH-55MES-230VO\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"hvx-desc-card\"\u003e\n\u003ch2 class=\"hvx-section-title\"\u003eOutdoor Specs\u003c\/h2\u003e\n\u003cdiv class=\"hvx-table-wrap\"\u003e\n\u003ctable aria-label=\"Outdoor unit specifications\" class=\"hvx-table\"\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eSpec\u003c\/th\u003e\n\u003cth\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCH-55MES-230VO\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRefrigerant Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eR410A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSystem Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMulti-zone unit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBTU Rated\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e55,000\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCooling Capacity (Min\/Max)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e55,000 (19,000–57,300) BTU\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eHeating Capacity (Min\/Max)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e55,000 (12,500–60,000) BTU\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSEER2 \/ EER2\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e21.3 \/ 10.5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eHSPF2-4 \/ HSPF2-5\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e9.1 \/ 6.8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCOP\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3.2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower Source\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e208–230V, 1Ph, 60Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eVoltage Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e187–253 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMinimum Circuit Ampacity (MCA)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e40 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMax Fuse\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e60 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMax Pipe Length\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e262 ft\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMax Height Difference (Indoor↔Outdoor)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e49.21 ft\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRefrigerant Piping (Liquid \/ Gas)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e5× 1\/4\" (liq) \/ 3× 3\/8\" + 2× 1\/2\" (gas)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRefrigerant Precharge\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eUp to 125 ft\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOutdoor Noise\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e62 dB(A)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOutdoor Air Flow\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4,500\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAmbient Range (Cooling)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e5–122 °F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAmbient Range (Heating)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-13–75 °F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAdditional Charge (3\/8\" liquid)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.32\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAdditional Charge (1\/4\" liquid)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.16\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eUnit Dimensions (W×H×D)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e37.48 × 16.34 × 52.48 in\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eUnit Net \/ Gross Weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e224.21 \/ 257.28 lb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePacking Dimensions (W×D×H)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e43.11 × 19.49 × 58.27\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDehumidification\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e12.72 pints\/day\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"hvx-desc-card\"\u003e\n\u003ch2 class=\"hvx-section-title\"\u003eVideos\u003c\/h2\u003e\n\u003cdiv style=\"margin: 8px 0 0;\"\u003e\n\u003cdiv style=\"font-weight: 800; margin: 10px 0 6px;\"\u003eMini-split installation videos\u003c\/div\u003e\n\u003cul style=\"padding-left: 18px; margin: 0;\"\u003e\n\u003cli\u003e\u003ca rel=\"noopener\" href=\"https:\/\/youtu.be\/Cxuiytm_CMo\" class=\"hvx-link\" target=\"_blank\"\u003eHow to Install Multi Zone Mini Split System (Cooper\u0026amp;Hunter) 2020\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca rel=\"noopener\" href=\"https:\/\/youtu.be\/JQkth-AM5CE\" class=\"hvx-link\" target=\"_blank\"\u003eFull Installation of Mini Split Ductless Unit, Step by Step!\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"margin: 12px 0 0;\"\u003e\n\u003cdiv style=\"font-weight: 800; margin: 10px 0 6px;\"\u003eProducts overview\u003c\/div\u003e\n\u003cul style=\"padding-left: 18px; margin: 0;\"\u003e\n\u003cli\u003e\u003ca rel=\"noopener\" href=\"https:\/\/youtu.be\/0kUh03W9qS8\" class=\"hvx-link\" target=\"_blank\"\u003eCooper\u0026amp;Hunter: Multi Zone AC for the Home\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca rel=\"noopener\" href=\"https:\/\/youtu.be\/2u0pa2jThCM\" class=\"hvx-link\" target=\"_blank\"\u003eHVAC Installation Kit: 99.9% Copper Line Sets (Cooper\u0026amp;Hunter)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca rel=\"noopener\" href=\"https:\/\/youtu.be\/qCWu8HCNl3Q\" class=\"hvx-link\" target=\"_blank\"\u003eMini Split Indoor Unit Types Explained\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"hvx-desc-card\"\u003e\n\u003ch2 class=\"hvx-section-title\"\u003eDocuments \u0026amp; Downloads\u003c\/h2\u003e\n\u003cul style=\"padding-left: 18px; margin: 8px 0;\"\u003e\n\u003cli\u003e\u003ca rel=\"noopener\" href=\"https:\/\/media.cooperandhunter.us\/3168\/CH-55MES-230VO-%28Ducted%29.pdf\" class=\"hvx-link\" target=\"_blank\"\u003eSubmittal — CH-55MES-230VO (Ducted) (PDF)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca rel=\"noopener\" href=\"https:\/\/media.cooperandhunter.us\/3169\/CH-55MES-230VO-%28Non-ducted%29.pdf\" class=\"hvx-link\" target=\"_blank\"\u003eSubmittal — CH-55MES-230VO (Non-Ducted) (PDF)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca rel=\"noopener\" href=\"https:\/\/media.cooperandhunter.us\/3759\/Accessories-Leaflet-2023.pdf\" class=\"hvx-link\" target=\"_blank\"\u003eAccessories — Leaflet (2023) (PDF)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca rel=\"noopener\" href=\"https:\/\/media.cooperandhunter.us\/1126\/QUICK-START-GUIDE.pdf\" class=\"hvx-link\" target=\"_blank\"\u003eQuick Start Guide (PDF)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca rel=\"noopener\" href=\"https:\/\/media.cooperandhunter.us\/4433\/Installation-manual.pdf\" class=\"hvx-link\" target=\"_blank\"\u003eInstallation Manual — Multi-Zone Outdoor (PDF)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca rel=\"noopener\" href=\"https:\/\/media.cooperandhunter.us\/3199\/MultiZone-Combination-Regular.pdf\" class=\"hvx-link\" target=\"_blank\"\u003eMulti-Zone Combination — Regular (PDF)\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"hvx-desc-card\"\u003e\n\u003ch2 class=\"hvx-section-title\"\u003eCertifications\u003c\/h2\u003e\n\u003cul style=\"padding-left: 18px; margin: 8px 0;\"\u003e\n\u003cli\u003eAHRI Ducted — \u003cstrong\u003e210799642\u003c\/strong\u003e (\u003ca rel=\"noopener\" href=\"https:\/\/www.ahridirectory.org\/NewSearch?programId=41\u0026amp;searchTypeId=3\u0026amp;productTypeId=4\" class=\"hvx-link\" target=\"_blank\"\u003eAHRI Directory\u003c\/a\u003e)\u003c\/li\u003e\n\u003cli\u003eAHRI Non-Ducted — \u003cstrong\u003e210799641\u003c\/strong\u003e (\u003ca rel=\"noopener\" href=\"https:\/\/www.ahridirectory.org\/NewSearch?programId=41\u0026amp;searchTypeId=3\u0026amp;productTypeId=4\" class=\"hvx-link\" target=\"_blank\"\u003eAHRI Directory\u003c\/a\u003e)\u003c\/li\u003e\n\u003cli\u003eAHRI Mixed — \u003cstrong\u003e210799643\u003c\/strong\u003e (\u003ca rel=\"noopener\" href=\"https:\/\/www.ahridirectory.org\/NewSearch?programId=41\u0026amp;searchTypeId=3\u0026amp;productTypeId=4\" class=\"hvx-link\" target=\"_blank\"\u003eAHRI Directory\u003c\/a\u003e)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"hvx-desc-card\"\u003e\n\u003ch2 class=\"hvx-section-title\"\u003eImportant\u003c\/h2\u003e\n\u003cp style=\"margin: 0; font-size: 14px;\"\u003eInstall with a licensed HVAC professional. This is a \u003cstrong\u003emulti-zone outdoor condenser\u003c\/strong\u003e intended to be matched with compatible indoor units. Confirm match-ups, total connected indoor capacity, and piping design before ordering. Observe maximum total piping (\u003cstrong\u003e262 ft\u003c\/strong\u003e), height limits (\u003cstrong\u003e49.21 ft\u003c\/strong\u003e), and required electrical protection (\u003cstrong\u003eMCA 40A\u003c\/strong\u003e, \u003cstrong\u003emax fuse 60A\u003c\/strong\u003e). Refrigerant is \u003cstrong\u003eR410A\u003c\/strong\u003e with factory precharge up to \u003cstrong\u003e125 ft\u003c\/strong\u003e; additional charge may be required beyond that length.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"hvx-desc-card\"\u003e\n\u003ch2 class=\"hvx-section-title\"\u003eFAQs\u003c\/h2\u003e\n\u003cdetails open=\"\" class=\"hvx-faq\"\u003e\n\u003csummary\u003eIs this a single-zone or multi-zone outdoor unit?\u003c\/summary\u003e\n\u003cdiv style=\"margin-top: 8px;\"\u003eThis model is a \u003cstrong\u003emulti-zone\u003c\/strong\u003e outdoor condenser.\u003c\/div\u003e\n\u003c\/details\u003e\n\u003cdetails open=\"\" class=\"hvx-faq\"\u003e\n\u003csummary\u003eHow many indoor units can it connect to?\u003c\/summary\u003e\n\u003cdiv style=\"margin-top: 8px;\"\u003eThe piping spec lists \u003cstrong\u003e5\u003c\/strong\u003e liquid connections and gas connections split between \u003cstrong\u003e3\/8\"\u003c\/strong\u003e and \u003cstrong\u003e1\/2\"\u003c\/strong\u003e, indicating support for up to \u003cstrong\u003efive zones\u003c\/strong\u003e when matched correctly.\u003c\/div\u003e\n\u003c\/details\u003e\n\u003cdetails open=\"\" class=\"hvx-faq\"\u003e\n\u003csummary\u003eWhat are the operating temperature ranges?\u003c\/summary\u003e\n\u003cdiv style=\"margin-top: 8px;\"\u003eCooling ambient range is \u003cstrong\u003e5–122°F\u003c\/strong\u003e. Heating ambient range is \u003cstrong\u003e-13–75°F\u003c\/strong\u003e.\u003c\/div\u003e\n\u003c\/details\u003e\n\u003cdetails open=\"\" class=\"hvx-faq\"\u003e\n\u003csummary\u003eHow much piping is supported?\u003c\/summary\u003e\n\u003cdiv style=\"margin-top: 8px;\"\u003eMaximum total piping length is \u003cstrong\u003e262 ft\u003c\/strong\u003e, with a maximum indoor\/outdoor height difference up to \u003cstrong\u003e49.21 ft\u003c\/strong\u003e.\u003c\/div\u003e\n\u003c\/details\u003e\n\u003cdetails open=\"\" class=\"hvx-faq\"\u003e\n\u003csummary\u003eDoes it come precharged with refrigerant?\u003c\/summary\u003e\n\u003cdiv style=\"margin-top: 8px;\"\u003eYes. The factory refrigerant precharge covers up to \u003cstrong\u003e125 ft\u003c\/strong\u003e of piping. Additional refrigerant may be required beyond that length.\u003c\/div\u003e\n\u003c\/details\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e","brand":"Cooper\u0026Hunter","offers":[{"title":"Default Title","offer_id":43086451736619,"sku":"CH-55MES-230VO","price":2930.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0625\/5647\/1339\/files\/48000_BTU.webp?v=1771368864"}],"url":"https:\/\/hvacsupplies.com\/collections\/ductless-multi-zone-standard-outdoor-units-cooper-and-hunter.oembed","provider":"HVACSupplies.com","version":"1.0","type":"link"}