{"title":"Ductless Multi-zone Hyper Heat Outdoor Units Cooper\u0026Hunter","description":null,"products":[{"product_id":"cooper-hunte-hyper-multi-zone-r454b-outdoor-condenser-19-000-btu-1-58-ton","title":"Cooper\u0026Hunte Hyper Multi-Zone R454B Outdoor Condenser 19,000 BTU (1.58 Ton)","description":"\u003cstyle\u003e\n  :root{\n    --hvx-golden:#FAA819;\n    --hvx-slate:#262626;\n    --hvx-ivory:#F4F1E6;\n    --hvx-border:#e2e0d5;\n    --hvx-card-bg:#ffffff;\n  }\n\n  .hvx-desc{\n    font-family:\"Articulat CF\",system-ui,-apple-system,BlinkMacSystemFont,\"Segoe UI\",sans-serif;\n    color:var(--hvx-slate);\n    line-height:1.6;\n    background:var(--hvx-ivory);\n    padding:18px 18px 20px;\n    border-radius:16px;\n  }\n\n  .hvx-desc-header{\n    border-radius:14px;\n    padding:14px 16px;\n    background:linear-gradient(120deg,var(--hvx-golden),var(--hvx-slate));\n    color:#fff;\n    margin:0 0 16px;\n    box-shadow:0 10px 24px rgba(0,0,0,.22);\n    display:flex;\n    align-items:flex-start;\n    gap:12px;\n    flex-wrap:wrap;\n  }\n\n  .hvx-header-text{display:flex;flex-direction:column;gap:4px;min-width:260px}\n  .hvx-eyebrow{\n    font-size:11px;\n    letter-spacing:.14em;\n    text-transform:uppercase;\n    opacity:.9;\n  }\n  .hvx-title{\n    margin:0;\n    font-family:\"Anton\",\"Impact\",system-ui,-apple-system,BlinkMacSystemFont,\"Segoe UI\",sans-serif;\n    font-size:22px;\n    line-height:1.15;\n  }\n\n  .hvx-desc-card{\n    border:1px solid var(--hvx-border);\n    border-radius:14px;\n    background:var(--hvx-card-bg);\n    padding:16px 18px 18px;\n    box-shadow:0 4px 12px rgba(0,0,0,.06);\n    margin:14px 0;\n  }\n\n  .hvx-section-title{\n    margin:0 0 10px;\n    font-family:\"Anton\",\"Impact\",system-ui,-apple-system,BlinkMacSystemFont,\"Segoe UI\",sans-serif;\n    font-size:17px;\n    letter-spacing:.08em;\n    text-transform:uppercase;\n    color:var(--hvx-slate);\n    display:inline-flex;\n    align-items:center;\n    gap:8px;\n  }\n  .hvx-section-title::after{\n    content:\"\";\n    flex:1;\n    height:2px;\n    border-radius:999px;\n    background:linear-gradient(90deg,var(--hvx-golden),transparent);\n    opacity:.9;\n  }\n\n  .hvx-cta{display:flex;flex-wrap:wrap;gap:10px;margin:10px 0 0}\n  .hvx-cta a{\n    display:inline-flex;\n    align-items:center;\n    gap:8px;\n    padding:10px 14px;\n    border-radius:12px;\n    border:1px solid var(--hvx-border);\n    background:#fff;\n    text-decoration:none;\n    color:var(--hvx-slate);\n    font-size:14px;\n    font-weight:700;\n  }\n  .hvx-cta a.primary{\n    background:var(--hvx-slate);\n    color:#fff;\n    border-color:transparent;\n  }\n\n  .hvx-badges{display:flex;flex-wrap:wrap;gap:8px;margin:10px 0 0}\n  .hvx-badge{\n    font-size:12px;\n    border:1px solid var(--hvx-border);\n    border-radius:999px;\n    padding:6px 10px;\n    background:#fff;\n    white-space:nowrap;\n  }\n\n  .hvx-kv{\n    display:grid;\n    grid-template-columns:repeat(4,minmax(160px,1fr));\n    gap:10px;\n    margin-top:10px;\n  }\n  .hvx-kv \u003e div{\n    border:1px solid var(--hvx-border);\n    background:#fff;\n    border-radius:12px;\n    padding:10px 12px;\n    text-align:center;\n  }\n  .hvx-kv strong{display:block}\n\n  .hvx-table{\n    width:100%;\n    border-collapse:collapse;\n    min-width:520px;\n    background:#fff;\n    border:1px solid var(--hvx-border);\n    border-radius:12px;\n    overflow:hidden;\n  }\n  .hvx-table th,.hvx-table td{\n    border-bottom:1px solid var(--hvx-border);\n    padding:10px 12px;\n    vertical-align:top;\n    font-size:14px;\n  }\n  .hvx-table th{ text-align:left; font-weight:800; background:#fff; }\n  .hvx-table tr:nth-child(odd) td{ background:#fff; }\n  .hvx-table tr:nth-child(even) td{ background:#fbfaf6; }\n  .hvx-table tr:last-child td{ border-bottom:none; }\n  .hvx-table-wrap{ overflow:auto; border-radius:12px; }\n\n  .hvx-note{\n    font-size:12px;\n    color:#555;\n    margin:10px 0 0;\n  }\n\n  details.hvx-faq{\n    border:1px solid var(--hvx-border);\n    background:#fff;\n    border-radius:12px;\n    padding:10px 12px;\n    margin:8px 0;\n  }\n  details.hvx-faq summary{\n    cursor:pointer;\n    font-weight:800;\n  }\n\n  @media(max-width:980px){\n    .hvx-kv{grid-template-columns:repeat(2,minmax(160px,1fr))}\n  }\n  @media(max-width:768px){\n    .hvx-desc{padding:14px 12px 16px;border-radius:12px}\n    .hvx-desc-header{padding:12px;border-radius:12px}\n    .hvx-title{font-size:19px}\n    .hvx-desc-card{padding:14px;margin:10px 0}\n  }\n\u003c\/style\u003e\n\u003cdiv class=\"hvx-desc\"\u003e\n\u003cdiv class=\"hvx-desc-header\"\u003e\n\u003cdiv class=\"hvx-header-text\"\u003e\n\u003cdiv class=\"hvx-eyebrow\"\u003eCooper\u0026amp;Hunter Hyper Heat Multi-Zone Outdoor • R454B • Up to 3 Zones\u003c\/div\u003e\n\u003ch1 class=\"hvx-title\"\u003eCooper\u0026amp;Hunter Hyper Heat Multi-Zone Outdoor — 19,000 BTU, R454B — CH-RVHP19M-230VO\u003c\/h1\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"hvx-cta\" aria-label=\"Contact options\"\u003e\n\u003ca class=\"primary\" href=\"https:\/\/hvacsupplies.com\/pages\/contact\" rel=\"noopener\" title=\"Contact Us\" target=\"_blank\"\u003e CLICK HERE TO CONTACT US FOR CUSTOM QUOTES AND QUESTIONS \u003c\/a\u003e \u003ca href=\"tel:+18005438933\" title=\"Call Us Now!\"\u003e CLICK TO CALL US 1-800-543-8933 FOR ANY QUESTIONS \u003c\/a\u003e \u003cbr\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"hvx-desc-card\"\u003e\n\u003ch2 class=\"hvx-section-title\"\u003eOverview\u003c\/h2\u003e\n\u003cp style=\"margin: 0;\"\u003eCooper\u0026amp;Hunter’s 19K BTU Hyper Heat Multi-Zone outdoor unit is built for efficient, personalized comfort in residential spaces. It supports up to three zones for independent room-by-room control and uses inverter technology to precisely adjust compressor output to match real-time demand. The Hyper Heat design delivers dependable heating in extreme weather, with heating operation rated down to −22 °F. With up to 25 SEER2 efficiency and R454B refrigerant (lower GWP vs. many conventional options), it’s a strong fit for high-performance, eco-conscious multi-zone installs.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"hvx-desc-card\"\u003e\n\u003ch2 class=\"hvx-section-title\"\u003eHighlights\u003c\/h2\u003e\n\u003cdiv class=\"hvx-badges\" role=\"list\"\u003e\n\u003cspan class=\"hvx-badge\" role=\"listitem\"\u003eUp to 3 zones\u003c\/span\u003e \u003cspan class=\"hvx-badge\" role=\"listitem\"\u003eSEER2 25 · EER2 15\u003c\/span\u003e \u003cspan class=\"hvx-badge\" role=\"listitem\"\u003eHSPF 10.4 (Region IV) · 8.5 (Region V)\u003c\/span\u003e \u003cspan class=\"hvx-badge\" role=\"listitem\"\u003eCOP 4.0 @ 47 °F\u003c\/span\u003e \u003cspan class=\"hvx-badge\" role=\"listitem\"\u003eHyper Heat to −22 °F\u003c\/span\u003e \u003cspan class=\"hvx-badge\" role=\"listitem\"\u003eR454B\u003c\/span\u003e \u003cspan class=\"hvx-badge\" role=\"listitem\"\u003e208–230V 1Ph\u003c\/span\u003e \u003cspan class=\"hvx-badge\" role=\"listitem\"\u003eMax total piping 196.8 ft\u003c\/span\u003e\n\u003c\/div\u003e\n\u003cul style=\"margin: 12px 0 0; padding-left: 18px;\"\u003e\n\u003cli\u003e\n\u003cstrong\u003eCold-climate heating:\u003c\/strong\u003e reliable heating operation down to −22 °F for harsh winter conditions.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHigh efficiency:\u003c\/strong\u003e up to 25 SEER2 for excellent seasonal energy savings.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInverter performance:\u003c\/strong\u003e dynamic modulation for stable comfort and lower operating cost.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEco-forward refrigerant:\u003c\/strong\u003e R454B supports a lower environmental footprint.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMulti-zone control:\u003c\/strong\u003e tailor comfort for up to three rooms\/areas with compatible indoor units.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cdiv class=\"hvx-kv\" role=\"list\" aria-label=\"At-a-glance\"\u003e\n\u003cdiv role=\"listitem\"\u003e\n\u003cstrong\u003eModel\u003c\/strong\u003eCH-RVHP19M-230VO\u003c\/div\u003e\n\u003cdiv role=\"listitem\"\u003e\n\u003cstrong\u003eZones\u003c\/strong\u003eUp to 3\u003c\/div\u003e\n\u003cdiv role=\"listitem\"\u003e\n\u003cstrong\u003eOutdoor Sound\u003c\/strong\u003e61.5 dB(A)\u003c\/div\u003e\n\u003cdiv role=\"listitem\"\u003e\n\u003cstrong\u003eLines\u003c\/strong\u003e3× 1\/4″ liquid · 3× 3\/8″ gas\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"hvx-desc-card\"\u003e\n\u003ch2 class=\"hvx-section-title\"\u003eWhat's Included\u003c\/h2\u003e\n\u003cul style=\"padding-left: 18px; margin: 8px 0;\"\u003e\n\u003cli\u003eOutdoor unit CH-RVHP19M-230VO\u003c\/li\u003e\n\u003cli\u003eOwner \/ installation documentation\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp class=\"hvx-note\"\u003ePair only with compatible Cooper\u0026amp;Hunter multi-zone indoor units. Confirm zone combinations, piping, and length limits before installation.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"hvx-desc-card\"\u003e\n\u003ch2 class=\"hvx-section-title\"\u003eIndoor Specs\u003c\/h2\u003e\n\u003cdiv class=\"hvx-table-wrap\"\u003e\n\u003ctable class=\"hvx-table\" aria-label=\"Indoor unit compatibility\"\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eSpec\u003c\/th\u003e\n\u003cth\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSystem type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eHyper Heat multi-zone outdoor unit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eZones supported\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eUp to 3 independent zones (depends on indoor unit selection)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRefrigerant piping\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3 circuits: 3× 1\/4″ liquid · 3× 3\/8″ gas\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMax total pipe length\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e196.8 ft\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMax length per indoor unit\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e98.4 ft\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMax height difference (IDU↔ODU)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e49.2 ft\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMax height difference (between indoor units)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e33 ft\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCombination guidance\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eUse the provided Multi-Zone Combination PDF to confirm valid indoor mixes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003cp class=\"hvx-note\"\u003eIndoor-unit capacities, controls, and features depend on the specific indoor models selected for each zone.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"hvx-desc-card\"\u003e\n\u003ch2 class=\"hvx-section-title\"\u003eOutdoor Specs\u003c\/h2\u003e\n\u003cdiv class=\"hvx-table-wrap\"\u003e\n\u003ctable class=\"hvx-table\" aria-label=\"Outdoor unit specifications\"\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eSpec\u003c\/th\u003e\n\u003cth\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCH-RVHP19M-230VO\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e208\/230 V, 1-Phase, 60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eVoltage range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e187–253 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCooling capacity (range)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e5,400–28,000 BTU\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCooling current (rated)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e5.6 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSEER2 \/ EER2\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e25 \/ 15\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eHeating capacity @ 47 °F (range)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e5,700–27,000 BTU\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eHeating current @ 47 °F (rated)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e6.5 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCOP @ 47 °F\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4.0 W\/W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eHSPF (Region IV \/ V)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e10.4 \/ 8.5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eHeating capacity @ 5 °F (rated)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e19,000 BTU\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMCA \/ Max fuse\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e17.5 A \/ 20 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOutdoor airflow (max)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2,130.7 CFM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOutdoor sound\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e61.5 dB(A)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eUnit size (W×D×H)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e37.24 × 16.14 × 31.89 in\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePacking size (W×D×H)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e42.91 × 19.68 × 34.84 in\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNet \/ Gross weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e137.35 \/ 148.15 lb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRefrigerant \/ Charge\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eR454B \/ 78.31 oz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFactory precharge\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e75 ft\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAdditional refrigerant charge\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.16 oz\/ft\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDesign pressure\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e550 \/ 340 PSIG\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAmbient range (cool \/ heat)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e−22–122 °F \/ −22–75 °F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eLine sizes\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eLiquid: 3× 1\/4″ · Gas: 3× 3\/8″\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMax piping (total \/ per indoor)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e196.8 ft \/ 98.4 ft\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMax height difference\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIDU↔ODU: 49.2 ft · Between IDUs: 33 ft\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003cp class=\"hvx-note\"\u003eCertifications: AHRI ✓ · Energy Star for Cold Climate ✓ · NEEP ✓ · ETL ✓.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"hvx-desc-card\"\u003e\n\u003ch2 class=\"hvx-section-title\"\u003eDocuments \u0026amp; Downloads\u003c\/h2\u003e\n\u003cul style=\"padding-left: 18px; margin: 8px 0;\"\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/media.cooperandhunter.us\/4808\/CH-RVHP19M-230VO.pdf\" rel=\"noopener\" target=\"_blank\"\u003eCH-RVHP19M-230VO Submittal (PDF)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/media.cooperandhunter.us\/4811\/RVHP-Installation-manual-Multi-Zone-Units_compressed.pdf\" rel=\"noopener\" target=\"_blank\"\u003eRVHP Multi-Zone Units Installation Manual (PDF)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/media.cooperandhunter.us\/3198\/MultiZone-Combination-HYPER.pdf\" rel=\"noopener\" target=\"_blank\"\u003eMulti-Zone Combination — HYPER (PDF)\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp class=\"hvx-note\"\u003eAHRI certification numbers (reference): Ducted 210799629 · Non-Ducted 210799628 · Mixed 210799630.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"hvx-desc-card\"\u003e\n\u003ch2 class=\"hvx-section-title\"\u003eImportant\u003c\/h2\u003e\n\u003cp class=\"hvx-note\" style=\"font-size: 14px; color: var(--hvx-slate); margin: 0;\"\u003eInstall by a licensed HVAC professional. Confirm zone combinations, electrical requirements (187–253 V), MCA\/max-fuse, line sizes, total\/branch piping limits, and ambient operating ranges (down to −22 °F) before commissioning.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"hvx-desc-card\"\u003e\n\u003ch2 class=\"hvx-section-title\"\u003eFAQs\u003c\/h2\u003e\n\u003cdetails class=\"hvx-faq\" open=\"\"\u003e\n\u003csummary\u003eHow many zones can this support?\u003c\/summary\u003e\n\u003cdiv style=\"margin-top: 8px;\"\u003eUp to three independent zones with compatible Cooper\u0026amp;Hunter multi-zone indoor units.\u003c\/div\u003e\n\u003c\/details\u003e\n\u003cdetails class=\"hvx-faq\" open=\"\"\u003e\n\u003csummary\u003eHow cold can it heat in Hyper Heat mode?\u003c\/summary\u003e\n\u003cdiv style=\"margin-top: 8px;\"\u003eHeating operation is rated down to −22 °F.\u003c\/div\u003e\n\u003c\/details\u003e\n\u003cdetails class=\"hvx-faq\" open=\"\"\u003e\n\u003csummary\u003eWhat line sizes are required?\u003c\/summary\u003e\n\u003cdiv style=\"margin-top: 8px;\"\u003eThree circuits total: 3× 1\/4″ liquid and 3× 3\/8″ gas connections.\u003c\/div\u003e\n\u003c\/details\u003e\n\u003cdetails class=\"hvx-faq\" open=\"\"\u003e\n\u003csummary\u003eWhat are the power requirements?\u003c\/summary\u003e\n\u003cdiv style=\"margin-top: 8px;\"\u003e208\/230 V, single-phase, 60 Hz. Voltage range 187–253 V. MCA 17.5 A. Max fuse 20 A.\u003c\/div\u003e\n\u003c\/details\u003e\n\u003cdetails class=\"hvx-faq\" open=\"\"\u003e\n\u003csummary\u003eWhat are the piping limits?\u003c\/summary\u003e\n\u003cdiv style=\"margin-top: 8px;\"\u003eUp to 196.8 ft total piping, and up to 98.4 ft for a single indoor unit run, within system design limits.\u003c\/div\u003e\n\u003c\/details\u003e\n\u003cdetails class=\"hvx-faq\" open=\"\"\u003e\n\u003csummary\u003eWhat refrigerant does it use?\u003c\/summary\u003e\n\u003cdiv style=\"margin-top: 8px;\"\u003eR454B (factory charge: 78.31 oz; precharge: 75 ft).\u003c\/div\u003e\n\u003c\/details\u003e\n\u003cdetails class=\"hvx-faq\" open=\"\"\u003e\n\u003csummary\u003eIs it certified for cold climate efficiency programs?\u003c\/summary\u003e\n\u003cdiv style=\"margin-top: 8px;\"\u003eIt lists Energy Star for Cold Climate, NEEP, ETL, and AHRI certifications.\u003c\/div\u003e\n\u003c\/details\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e","brand":"Cooper\u0026Hunter","offers":[{"title":"Default Title","offer_id":42697724592171,"sku":"CH-RVHP19M-230VO","price":2299.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0625\/5647\/1339\/files\/19000BTUHYPER_1.png?v=1769188233"},{"product_id":"cooper-hunter-hyper-multi-zone-r454b-outdoor-condenser-28-000-btu-2-33-ton","title":"Cooper\u0026Hunter Hyper Multi-Zone R454B Outdoor Condenser 28,000 BTU (2.33 Ton)","description":"\u003cstyle\u003e\n  :root{\n    --hvx-golden:#FAA819;\n    --hvx-slate:#262626;\n    --hvx-ivory:#F4F1E6;\n    --hvx-border:#e2e0d5;\n    --hvx-card-bg:#ffffff;\n  }\n\n  .hvx-desc{\n    font-family:\"Articulat CF\",system-ui,-apple-system,BlinkMacSystemFont,\"Segoe UI\",sans-serif;\n    color:var(--hvx-slate);\n    line-height:1.6;\n    background:var(--hvx-ivory);\n    padding:18px 18px 20px;\n    border-radius:16px;\n  }\n\n  .hvx-desc-header{\n    border-radius:14px;\n    padding:14px 16px;\n    background:linear-gradient(120deg,var(--hvx-golden),var(--hvx-slate));\n    color:#fff;\n    margin:0 0 16px;\n    box-shadow:0 10px 24px rgba(0,0,0,.22);\n    display:flex;\n    align-items:flex-start;\n    gap:12px;\n    flex-wrap:wrap;\n  }\n\n  .hvx-header-text{display:flex;flex-direction:column;gap:4px;min-width:260px}\n  .hvx-eyebrow{\n    font-size:11px;\n    letter-spacing:.14em;\n    text-transform:uppercase;\n    opacity:.9;\n  }\n  .hvx-title{\n    margin:0;\n    font-family:\"Anton\",\"Impact\",system-ui,-apple-system,BlinkMacSystemFont,\"Segoe UI\",sans-serif;\n    font-size:22px;\n    line-height:1.15;\n  }\n\n  .hvx-desc-card{\n    border:1px solid var(--hvx-border);\n    border-radius:14px;\n    background:var(--hvx-card-bg);\n    padding:16px 18px 18px;\n    box-shadow:0 4px 12px rgba(0,0,0,.06);\n    margin:14px 0;\n  }\n\n  .hvx-section-title{\n    margin:0 0 10px;\n    font-family:\"Anton\",\"Impact\",system-ui,-apple-system,BlinkMacSystemFont,\"Segoe UI\",sans-serif;\n    font-size:17px;\n    letter-spacing:.08em;\n    text-transform:uppercase;\n    color:var(--hvx-slate);\n    display:inline-flex;\n    align-items:center;\n    gap:8px;\n  }\n  .hvx-section-title::after{\n    content:\"\";\n    flex:1;\n    height:2px;\n    border-radius:999px;\n    background:linear-gradient(90deg,var(--hvx-golden),transparent);\n    opacity:.9;\n  }\n\n  .hvx-cta{display:flex;flex-wrap:wrap;gap:10px;margin:10px 0 0}\n  .hvx-cta a{\n    display:inline-flex;\n    align-items:center;\n    gap:8px;\n    padding:10px 14px;\n    border-radius:12px;\n    border:1px solid var(--hvx-border);\n    background:#fff;\n    text-decoration:none;\n    color:var(--hvx-slate);\n    font-size:14px;\n    font-weight:700;\n  }\n  .hvx-cta a.primary{\n    background:var(--hvx-slate);\n    color:#fff;\n    border-color:transparent;\n  }\n\n  .hvx-badges{display:flex;flex-wrap:wrap;gap:8px;margin:10px 0 0}\n  .hvx-badge{\n    font-size:12px;\n    border:1px solid var(--hvx-border);\n    border-radius:999px;\n    padding:6px 10px;\n    background:#fff;\n    white-space:nowrap;\n  }\n\n  .hvx-kv{\n    display:grid;\n    grid-template-columns:repeat(4,minmax(160px,1fr));\n    gap:10px;\n    margin-top:10px;\n  }\n  .hvx-kv \u003e div{\n    border:1px solid var(--hvx-border);\n    background:#fff;\n    border-radius:12px;\n    padding:10px 12px;\n    text-align:center;\n  }\n  .hvx-kv strong{display:block}\n\n  .hvx-table{\n    width:100%;\n    border-collapse:collapse;\n    min-width:520px;\n    background:#fff;\n    border:1px solid var(--hvx-border);\n    border-radius:12px;\n    overflow:hidden;\n  }\n  .hvx-table th,.hvx-table td{\n    border-bottom:1px solid var(--hvx-border);\n    padding:10px 12px;\n    vertical-align:top;\n    font-size:14px;\n  }\n  .hvx-table th{ text-align:left; font-weight:800; background:#fff; }\n  .hvx-table tr:nth-child(odd) td{ background:#fff; }\n  .hvx-table tr:nth-child(even) td{ background:#fbfaf6; }\n  .hvx-table tr:last-child td{ border-bottom:none; }\n  .hvx-table-wrap{ overflow:auto; border-radius:12px; }\n\n  .hvx-note{\n    font-size:12px;\n    color:#555;\n    margin:10px 0 0;\n  }\n\n  details.hvx-faq{\n    border:1px solid var(--hvx-border);\n    background:#fff;\n    border-radius:12px;\n    padding:10px 12px;\n    margin:8px 0;\n  }\n  details.hvx-faq summary{\n    cursor:pointer;\n    font-weight:800;\n  }\n\n  @media(max-width:980px){\n    .hvx-kv{grid-template-columns:repeat(2,minmax(160px,1fr))}\n  }\n  @media(max-width:768px){\n    .hvx-desc{padding:14px 12px 16px;border-radius:12px}\n    .hvx-desc-header{padding:12px;border-radius:12px}\n    .hvx-title{font-size:19px}\n    .hvx-desc-card{padding:14px;margin:10px 0}\n  }\n\u003c\/style\u003e\n\u003cdiv class=\"hvx-desc\"\u003e\n\u003cdiv class=\"hvx-desc-header\"\u003e\n\u003cdiv class=\"hvx-header-text\"\u003e\n\u003cdiv class=\"hvx-eyebrow\"\u003eCooper\u0026amp;Hunter Hyper Heat Multi-Zone Outdoor • R454B • Up to 4 Zones\u003c\/div\u003e\n\u003ch1 class=\"hvx-title\"\u003eCooper\u0026amp;Hunter Hyper Heat Multi-Zone Outdoor — 28,000 BTU, R454B — CH-RVHP28M-230VO\u003c\/h1\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"hvx-cta\" aria-label=\"Contact options\"\u003e\n\u003ca class=\"primary\" href=\"https:\/\/hvacsupplies.com\/pages\/contact\" rel=\"noopener\" title=\"Contact Us\" target=\"_blank\"\u003e CLICK HERE TO CONTACT US FOR CUSTOM QUOTES AND QUESTIONS \u003c\/a\u003e \u003ca href=\"tel:+18005438933\" title=\"Call Us Now!\"\u003e CLICK TO CALL US 1-800-543-8933 FOR ANY QUESTIONS \u003c\/a\u003e \u003cbr\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"hvx-desc-card\"\u003e\n\u003ch2 class=\"hvx-section-title\"\u003eOverview\u003c\/h2\u003e\n\u003cp style=\"margin: 0;\"\u003eCooper\u0026amp;Hunter’s 28K BTU Hyper Heat Multi-Zone outdoor unit delivers high-performance comfort for residential spaces with up to four zones of independent room-by-room control. Hyper Heating technology provides dependable operation in extreme cold, with heating rated down to −22 °F. Inverter technology dynamically adjusts compressor output to match zone demand for efficient, steady performance. With up to 23 SEER2 efficiency and R454B refrigerant (lower GWP vs. many conventional options), it’s built for modern, eco-conscious multi-zone installations.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"hvx-desc-card\"\u003e\n\u003ch2 class=\"hvx-section-title\"\u003eHighlights\u003c\/h2\u003e\n\u003cdiv class=\"hvx-badges\" role=\"list\"\u003e\n\u003cspan class=\"hvx-badge\" role=\"listitem\"\u003eUp to 4 zones\u003c\/span\u003e \u003cspan class=\"hvx-badge\" role=\"listitem\"\u003eSEER2 23 · EER2 12.5\u003c\/span\u003e \u003cspan class=\"hvx-badge\" role=\"listitem\"\u003eHSPF 10.5 (Region IV) · 8.5 (Region V)\u003c\/span\u003e \u003cspan class=\"hvx-badge\" role=\"listitem\"\u003eCOP 3.8 @ 47 °F\u003c\/span\u003e \u003cspan class=\"hvx-badge\" role=\"listitem\"\u003eHyper Heat to −22 °F\u003c\/span\u003e \u003cspan class=\"hvx-badge\" role=\"listitem\"\u003eR454B\u003c\/span\u003e \u003cspan class=\"hvx-badge\" role=\"listitem\"\u003e208–230V 1Ph\u003c\/span\u003e \u003cspan class=\"hvx-badge\" role=\"listitem\"\u003eMax total piping 262.4 ft\u003c\/span\u003e\n\u003c\/div\u003e\n\u003cul style=\"margin: 12px 0 0; padding-left: 18px;\"\u003e\n\u003cli\u003e\n\u003cstrong\u003eCold-climate heating:\u003c\/strong\u003e heating operation rated down to −22 °F.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMulti-zone control:\u003c\/strong\u003e supports up to four independent zones with compatible indoor units.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEnergy smart:\u003c\/strong\u003e inverter-driven operation with up to 23 SEER2 efficiency.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEco-forward refrigerant:\u003c\/strong\u003e R454B helps reduce environmental impact.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInstaller-friendly:\u003c\/strong\u003e generous piping allowances for flexible layouts (within design limits).\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cdiv class=\"hvx-kv\" role=\"list\" aria-label=\"At-a-glance\"\u003e\n\u003cdiv role=\"listitem\"\u003e\n\u003cstrong\u003eModel\u003c\/strong\u003eCH-RVHP28M-230VO\u003c\/div\u003e\n\u003cdiv role=\"listitem\"\u003e\n\u003cstrong\u003eZones\u003c\/strong\u003eUp to 4\u003c\/div\u003e\n\u003cdiv role=\"listitem\"\u003e\n\u003cstrong\u003eOutdoor Sound\u003c\/strong\u003e61 dB(A)\u003c\/div\u003e\n\u003cdiv role=\"listitem\"\u003e\n\u003cstrong\u003eLines\u003c\/strong\u003e4× 1\/4″ liquid · (3× 3\/8″ + 1× 1\/2″) gas\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"hvx-desc-card\"\u003e\n\u003ch2 class=\"hvx-section-title\"\u003eWhat's Included\u003c\/h2\u003e\n\u003cul style=\"padding-left: 18px; margin: 8px 0;\"\u003e\n\u003cli\u003eOutdoor unit CH-RVHP28M-230VO\u003c\/li\u003e\n\u003cli\u003eOwner \/ installation documentation\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp class=\"hvx-note\"\u003ePair only with compatible Cooper\u0026amp;Hunter multi-zone indoor units. Confirm zone combinations, piping, and length limits before installation.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"hvx-desc-card\"\u003e\n\u003ch2 class=\"hvx-section-title\"\u003eIndoor Specs\u003c\/h2\u003e\n\u003cdiv class=\"hvx-table-wrap\"\u003e\n\u003ctable class=\"hvx-table\" aria-label=\"Indoor unit compatibility\"\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eSpec\u003c\/th\u003e\n\u003cth\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSystem type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eHyper Heat multi-zone outdoor unit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eZones supported\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eUp to 4 independent zones (depends on indoor unit selection)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRefrigerant piping\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4 circuits: 4× 1\/4″ liquid · gas connections are 3× 3\/8″ + 1× 1\/2″\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMax total pipe length\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e262.4 ft\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMax length per indoor unit\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e114.8 ft\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMax height difference (IDU↔ODU)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e49.2 ft\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMax height difference (between indoor units)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e33 ft\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCombination guidance\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eUse the provided Multi-Zone Combination PDF to confirm valid indoor mixes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003cp class=\"hvx-note\"\u003eIndoor-unit capacities, controls, and features depend on the specific indoor models selected for each zone.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"hvx-desc-card\"\u003e\n\u003ch2 class=\"hvx-section-title\"\u003eOutdoor Specs\u003c\/h2\u003e\n\u003cdiv class=\"hvx-table-wrap\"\u003e\n\u003ctable class=\"hvx-table\" aria-label=\"Outdoor unit specifications\"\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eSpec\u003c\/th\u003e\n\u003cth\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCH-RVHP28M-230VO\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e208\/230 V, 1-Phase, 60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eVoltage range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e187–253 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCooling capacity (range)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e7,200–37,000 BTU\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCooling current (rated)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e9.5 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSEER2 \/ EER2\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e23 \/ 12.5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eHeating capacity @ 47 °F (range)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e8,400–36,000 BTU\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eHeating current @ 47 °F (rated)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e9.1 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCOP @ 47 °F\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3.8 W\/W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eHSPF (Region IV \/ V)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e10.5 \/ 8.5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eHeating capacity @ 5 °F (rated)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e27,000 BTU\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMCA \/ Max fuse\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e30 A \/ 35 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOutdoor airflow (max)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2,148.4 CFM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOutdoor sound\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e61 dB(A)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eUnit size (W×D×H)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e37.24 × 16.14 × 31.89 in\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePacking size (W×D×H)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e42.91 × 19.68 × 34.84 in\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNet \/ Gross weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e168.43 \/ 179.67 lb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRefrigerant \/ Charge\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eR454B \/ 120.63 oz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFactory precharge\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e100 ft\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAdditional refrigerant charge\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.16 oz\/ft\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDesign pressure\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e550 \/ 340 PSIG\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAmbient range (cool \/ heat)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e−22–122 °F \/ −22–75 °F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eLine sizes\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eLiquid: 4× 1\/4″ · Gas: 3× 3\/8″ + 1× 1\/2″\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMax piping (total \/ per indoor)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e262.4 ft \/ 114.8 ft\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMax height difference\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIDU↔ODU: 49.2 ft · Between IDUs: 33 ft\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"hvx-desc-card\"\u003e\n\u003ch2 class=\"hvx-section-title\"\u003eDocuments \u0026amp; Downloads\u003c\/h2\u003e\n\u003cul style=\"padding-left: 18px; margin: 8px 0;\"\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/media.cooperandhunter.us\/4809\/CH-RVHP28M-230VO.pdf\" rel=\"noopener\" target=\"_blank\"\u003eCH-RVHP28M-230VO Submittal (PDF)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/media.cooperandhunter.us\/4433\/Installation-manual.pdf\" rel=\"noopener\" target=\"_blank\"\u003eInstallation Manual (PDF)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/media.cooperandhunter.us\/4811\/RVHP-Installation-manual-Multi-Zone-Units_compressed.pdf\" rel=\"noopener\" target=\"_blank\"\u003eRVHP Multi-Zone Units Installation Manual (PDF)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/media.cooperandhunter.us\/3198\/MultiZone-Combination-HYPER.pdf\" rel=\"noopener\" target=\"_blank\"\u003eMulti-Zone Combination — HYPER (PDF)\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp class=\"hvx-note\"\u003eAHRI certification numbers (reference): Ducted 210799632 · Non-Ducted 210799631 · Mixed 210799633.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"hvx-desc-card\"\u003e\n\u003ch2 class=\"hvx-section-title\"\u003eImportant\u003c\/h2\u003e\n\u003cp class=\"hvx-note\" style=\"font-size: 14px; color: var(--hvx-slate); margin: 0;\"\u003eInstall by a licensed HVAC professional. Confirm zone combinations, electrical requirements (187–253 V), MCA\/max-fuse, line sizes (including the 1\/2″ gas circuit), total\/branch piping limits, and ambient operating ranges (down to −22 °F) before commissioning.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"hvx-desc-card\"\u003e\n\u003ch2 class=\"hvx-section-title\"\u003eFAQs\u003c\/h2\u003e\n\u003cdetails class=\"hvx-faq\" open=\"\"\u003e\n\u003csummary\u003eHow many zones can this support?\u003c\/summary\u003e\n\u003cdiv style=\"margin-top: 8px;\"\u003eUp to four independent zones with compatible Cooper\u0026amp;Hunter multi-zone indoor units.\u003c\/div\u003e\n\u003c\/details\u003e\n\u003cdetails class=\"hvx-faq\" open=\"\"\u003e\n\u003csummary\u003eHow cold can it heat in Hyper Heat mode?\u003c\/summary\u003e\n\u003cdiv style=\"margin-top: 8px;\"\u003eHeating operation is rated down to −22 °F.\u003c\/div\u003e\n\u003c\/details\u003e\n\u003cdetails class=\"hvx-faq\" open=\"\"\u003e\n\u003csummary\u003eWhat line sizes are required?\u003c\/summary\u003e\n\u003cdiv style=\"margin-top: 8px;\"\u003eFour circuits total: 4× 1\/4″ liquid and gas connections of 3× 3\/8″ plus 1× 1\/2″.\u003c\/div\u003e\n\u003c\/details\u003e\n\u003cdetails class=\"hvx-faq\" open=\"\"\u003e\n\u003csummary\u003eWhat are the power requirements?\u003c\/summary\u003e\n\u003cdiv style=\"margin-top: 8px;\"\u003e208\/230 V, single-phase, 60 Hz. Voltage range 187–253 V. MCA 30 A. Max fuse 35 A.\u003c\/div\u003e\n\u003c\/details\u003e\n\u003cdetails class=\"hvx-faq\" open=\"\"\u003e\n\u003csummary\u003eWhat are the piping limits?\u003c\/summary\u003e\n\u003cdiv style=\"margin-top: 8px;\"\u003eUp to 262.4 ft total piping, and up to 114.8 ft for a single indoor unit run, within system design limits.\u003c\/div\u003e\n\u003c\/details\u003e\n\u003cdetails class=\"hvx-faq\" open=\"\"\u003e\n\u003csummary\u003eWhat refrigerant does it use?\u003c\/summary\u003e\n\u003cdiv style=\"margin-top: 8px;\"\u003eR454B (factory charge: 120.63 oz; precharge: 100 ft).\u003c\/div\u003e\n\u003c\/details\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e","brand":"Cooper\u0026Hunter","offers":[{"title":"Default Title","offer_id":42697727639595,"sku":"CH-RVHP28M-230VO","price":2867.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0625\/5647\/1339\/files\/19000BTUHYPER_1.png?v=1769188233"},{"product_id":"cooper-hunter-hyper-multi-zone-r454b-outdoor-condenser-36-000-btu-3-ton","title":"Cooper\u0026Hunter Hyper Multi-Zone R454B Outdoor Condenser 36,000 BTU (3 Ton)","description":"\u003cstyle\u003e\n  :root{\n    --hvx-golden:#FAA819;\n    --hvx-slate:#262626;\n    --hvx-ivory:#F4F1E6;\n    --hvx-border:#e2e0d5;\n    --hvx-card-bg:#ffffff;\n  }\n\n  .hvx-desc{\n    font-family:\"Articulat CF\",system-ui,-apple-system,BlinkMacSystemFont,\"Segoe UI\",sans-serif;\n    color:var(--hvx-slate);\n    line-height:1.6;\n    background:var(--hvx-ivory);\n    padding:18px 18px 20px;\n    border-radius:16px;\n  }\n\n  .hvx-desc-header{\n    border-radius:14px;\n    padding:14px 16px;\n    background:linear-gradient(120deg,var(--hvx-golden),var(--hvx-slate));\n    color:#fff;\n    margin:0 0 16px;\n    box-shadow:0 10px 24px rgba(0,0,0,.22);\n    display:flex;\n    align-items:flex-start;\n    gap:12px;\n    flex-wrap:wrap;\n  }\n\n  .hvx-header-text{display:flex;flex-direction:column;gap:4px;min-width:260px}\n  .hvx-eyebrow{\n    font-size:11px;\n    letter-spacing:.14em;\n    text-transform:uppercase;\n    opacity:.9;\n  }\n  .hvx-title{\n    margin:0;\n    font-family:\"Anton\",\"Impact\",system-ui,-apple-system,BlinkMacSystemFont,\"Segoe UI\",sans-serif;\n    font-size:22px;\n    line-height:1.15;\n  }\n\n  .hvx-desc-card{\n    border:1px solid var(--hvx-border);\n    border-radius:14px;\n    background:var(--hvx-card-bg);\n    padding:16px 18px 18px;\n    box-shadow:0 4px 12px rgba(0,0,0,.06);\n    margin:14px 0;\n  }\n\n  .hvx-section-title{\n    margin:0 0 10px;\n    font-family:\"Anton\",\"Impact\",system-ui,-apple-system,BlinkMacSystemFont,\"Segoe UI\",sans-serif;\n    font-size:17px;\n    letter-spacing:.08em;\n    text-transform:uppercase;\n    color:var(--hvx-slate);\n    display:inline-flex;\n    align-items:center;\n    gap:8px;\n  }\n  .hvx-section-title::after{\n    content:\"\";\n    flex:1;\n    height:2px;\n    border-radius:999px;\n    background:linear-gradient(90deg,var(--hvx-golden),transparent);\n    opacity:.9;\n  }\n\n  .hvx-cta{display:flex;flex-wrap:wrap;gap:10px;margin:10px 0 0}\n  .hvx-cta a{\n    display:inline-flex;\n    align-items:center;\n    gap:8px;\n    padding:10px 14px;\n    border-radius:12px;\n    border:1px solid var(--hvx-border);\n    background:#fff;\n    text-decoration:none;\n    color:var(--hvx-slate);\n    font-size:14px;\n    font-weight:700;\n  }\n  .hvx-cta a.primary{\n    background:var(--hvx-slate);\n    color:#fff;\n    border-color:transparent;\n  }\n\n  .hvx-badges{display:flex;flex-wrap:wrap;gap:8px;margin:10px 0 0}\n  .hvx-badge{\n    font-size:12px;\n    border:1px solid var(--hvx-border);\n    border-radius:999px;\n    padding:6px 10px;\n    background:#fff;\n    white-space:nowrap;\n  }\n\n  .hvx-kv{\n    display:grid;\n    grid-template-columns:repeat(4,minmax(160px,1fr));\n    gap:10px;\n    margin-top:10px;\n  }\n  .hvx-kv \u003e div{\n    border:1px solid var(--hvx-border);\n    background:#fff;\n    border-radius:12px;\n    padding:10px 12px;\n    text-align:center;\n  }\n  .hvx-kv strong{display:block}\n\n  .hvx-table{\n    width:100%;\n    border-collapse:collapse;\n    min-width:520px;\n    background:#fff;\n    border:1px solid var(--hvx-border);\n    border-radius:12px;\n    overflow:hidden;\n  }\n  .hvx-table th,.hvx-table td{\n    border-bottom:1px solid var(--hvx-border);\n    padding:10px 12px;\n    vertical-align:top;\n    font-size:14px;\n  }\n  .hvx-table th{ text-align:left; font-weight:800; background:#fff; }\n  .hvx-table tr:nth-child(odd) td{ background:#fff; }\n  .hvx-table tr:nth-child(even) td{ background:#fbfaf6; }\n  .hvx-table tr:last-child td{ border-bottom:none; }\n  .hvx-table-wrap{ overflow:auto; border-radius:12px; }\n\n  .hvx-note{\n    font-size:12px;\n    color:#555;\n    margin:10px 0 0;\n  }\n\n  details.hvx-faq{\n    border:1px solid var(--hvx-border);\n    background:#fff;\n    border-radius:12px;\n    padding:10px 12px;\n    margin:8px 0;\n  }\n  details.hvx-faq summary{\n    cursor:pointer;\n    font-weight:800;\n  }\n\n  @media(max-width:980px){\n    .hvx-kv{grid-template-columns:repeat(2,minmax(160px,1fr))}\n  }\n  @media(max-width:768px){\n    .hvx-desc{padding:14px 12px 16px;border-radius:12px}\n    .hvx-desc-header{padding:12px;border-radius:12px}\n    .hvx-title{font-size:19px}\n    .hvx-desc-card{padding:14px;margin:10px 0}\n  }\n\u003c\/style\u003e\n\u003cdiv class=\"hvx-desc\"\u003e\n\u003cdiv class=\"hvx-desc-header\"\u003e\n\u003cdiv class=\"hvx-header-text\"\u003e\n\u003cdiv class=\"hvx-eyebrow\"\u003eCooper\u0026amp;Hunter Hyper Heat Multi-Zone Outdoor • R454B • Up to 5 Zones\u003c\/div\u003e\n\u003ch1 class=\"hvx-title\"\u003eCooper\u0026amp;Hunter Hyper Heat Multi-Zone Outdoor — 36,000 BTU, R454B — CH-RVHP36M-230VO\u003c\/h1\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"hvx-cta\" aria-label=\"Contact options\"\u003e\n\u003ca class=\"primary\" href=\"https:\/\/hvacsupplies.com\/pages\/contact\" rel=\"noopener\" title=\"Contact Us\" target=\"_blank\"\u003e CLICK HERE TO CONTACT US FOR CUSTOM QUOTES AND QUESTIONS \u003c\/a\u003e \u003ca href=\"tel:+18005438933\" title=\"Call Us Now!\"\u003e CLICK TO CALL US 1-800-543-8933 FOR ANY QUESTIONS \u003c\/a\u003e \u003cbr\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"hvx-desc-card\"\u003e\n\u003ch2 class=\"hvx-section-title\"\u003eOverview\u003c\/h2\u003e\n\u003cp style=\"margin: 0;\"\u003eCooper\u0026amp;Hunter’s 36K BTU Hyper Heat Multi-Zone outdoor unit is designed for powerful, efficient climate control in larger residential spaces. Supporting up to five zones, it provides independent temperature settings for multiple rooms, delivering personalized comfort throughout the home. Hyper Heating technology enables reliable performance in extreme cold, with heating operation rated down to −22 °F. Inverter technology dynamically modulates compressor output to match demand across zones for steady comfort and strong efficiency. With up to 23 SEER2 and R454B refrigerant (lower GWP vs. many conventional options), it’s a modern, eco-conscious solution for multi-zone installations.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"hvx-desc-card\"\u003e\n\u003ch2 class=\"hvx-section-title\"\u003eHighlights\u003c\/h2\u003e\n\u003cdiv class=\"hvx-badges\" role=\"list\"\u003e\n\u003cspan class=\"hvx-badge\" role=\"listitem\"\u003eUp to 5 zones\u003c\/span\u003e \u003cspan class=\"hvx-badge\" role=\"listitem\"\u003eSEER2 23 · EER2 13\u003c\/span\u003e \u003cspan class=\"hvx-badge\" role=\"listitem\"\u003eHSPF 10.7 (Region IV) · 8.5 (Region V)\u003c\/span\u003e \u003cspan class=\"hvx-badge\" role=\"listitem\"\u003eCOP 4.0 @ 47 °F\u003c\/span\u003e \u003cspan class=\"hvx-badge\" role=\"listitem\"\u003eHyper Heat to −22 °F\u003c\/span\u003e \u003cspan class=\"hvx-badge\" role=\"listitem\"\u003eR454B\u003c\/span\u003e \u003cspan class=\"hvx-badge\" role=\"listitem\"\u003e208–230V 1Ph\u003c\/span\u003e \u003cspan class=\"hvx-badge\" role=\"listitem\"\u003eMax total piping 262.4 ft\u003c\/span\u003e\n\u003c\/div\u003e\n\u003cul style=\"margin: 12px 0 0; padding-left: 18px;\"\u003e\n\u003cli\u003e\n\u003cstrong\u003eFive-zone flexibility:\u003c\/strong\u003e supports up to five independent zones with compatible indoor units.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCold-climate heating:\u003c\/strong\u003e heating operation rated down to −22 °F.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEnergy smart:\u003c\/strong\u003e inverter-driven operation with up to 23 SEER2 efficiency.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEco-forward refrigerant:\u003c\/strong\u003e R454B helps reduce environmental impact.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHigh-capacity comfort:\u003c\/strong\u003e strong low-temp performance for larger layouts and multi-room needs.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cdiv class=\"hvx-kv\" role=\"list\" aria-label=\"At-a-glance\"\u003e\n\u003cdiv role=\"listitem\"\u003e\n\u003cstrong\u003eModel\u003c\/strong\u003eCH-RVHP36M-230VO\u003c\/div\u003e\n\u003cdiv role=\"listitem\"\u003e\n\u003cstrong\u003eZones\u003c\/strong\u003eUp to 5\u003c\/div\u003e\n\u003cdiv role=\"listitem\"\u003e\n\u003cstrong\u003eOutdoor Sound\u003c\/strong\u003e65 dB(A)\u003c\/div\u003e\n\u003cdiv role=\"listitem\"\u003e\n\u003cstrong\u003eLines\u003c\/strong\u003e5× 1\/4″ liquid · (3× 3\/8″ + 2× 1\/2″) gas\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"hvx-desc-card\"\u003e\n\u003ch2 class=\"hvx-section-title\"\u003eWhat's Included\u003c\/h2\u003e\n\u003cul style=\"padding-left: 18px; margin: 8px 0;\"\u003e\n\u003cli\u003eOutdoor unit CH-RVHP36M-230VO\u003c\/li\u003e\n\u003cli\u003eOwner \/ installation documentation\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp class=\"hvx-note\"\u003ePair only with compatible Cooper\u0026amp;Hunter multi-zone indoor units. Confirm zone combinations, piping, and length limits before installation.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"hvx-desc-card\"\u003e\n\u003ch2 class=\"hvx-section-title\"\u003eIndoor Specs\u003c\/h2\u003e\n\u003cdiv class=\"hvx-table-wrap\"\u003e\n\u003ctable class=\"hvx-table\" aria-label=\"Indoor unit compatibility\"\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eSpec\u003c\/th\u003e\n\u003cth\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSystem type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eHyper Heat multi-zone outdoor unit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eZones supported\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eUp to 5 independent zones (depends on indoor unit selection)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRefrigerant piping\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e5 circuits: 5× 1\/4″ liquid · gas connections are 3× 3\/8″ + 2× 1\/2″\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMax total pipe length\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e262.4 ft\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMax length per indoor unit\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e114.8 ft\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMax height difference (IDU↔ODU)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e49.2 ft\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMax height difference (between indoor units)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e33 ft\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCombination guidance\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eConfirm indoor unit mixes per the applicable submittal documentation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003cp class=\"hvx-note\"\u003eIndoor-unit capacities, controls, and features depend on the specific indoor models selected for each zone.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"hvx-desc-card\"\u003e\n\u003ch2 class=\"hvx-section-title\"\u003eOutdoor Specs\u003c\/h2\u003e\n\u003cdiv class=\"hvx-table-wrap\"\u003e\n\u003ctable class=\"hvx-table\" aria-label=\"Outdoor unit specifications\"\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eSpec\u003c\/th\u003e\n\u003cth\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCH-RVHP36M-230VO\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e208\/230 V, 1-Phase, 60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eVoltage range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e187–253 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCooling capacity (range)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e9,000–43,000 BTU\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCooling current (rated)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e12 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSEER2 \/ EER2\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e23 \/ 13\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eHeating capacity @ 47 °F (range)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e10,000–44,000 BTU\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eHeating current @ 47 °F (rated)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e11.5 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCOP @ 47 °F\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4.0 W\/W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eHSPF (Region IV \/ V)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e10.7 \/ 8.5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eHeating capacity @ 5 °F (rated)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e36,000 BTU\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMCA \/ Max fuse\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e37 A \/ 40 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOutdoor airflow (max)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3,037.2 CFM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOutdoor sound\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e65 dB(A)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eUnit size (W×D×H)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e38.58 × 16.34 × 38.39 in\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePacking size (W×D×H)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e45.08 × 19.68 × 42.52 in\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNet \/ Gross weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e211.86 \/ 244.71 lb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRefrigerant \/ Charge\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eR454B \/ 134.04 oz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFactory precharge\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e125 ft\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAdditional refrigerant charge\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.16 oz\/ft\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDesign pressure\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e550 \/ 340 PSIG\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAmbient range (cool \/ heat)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e−22–122 °F \/ −22–75 °F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eLine sizes\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eLiquid: 5× 1\/4″ · Gas: 3× 3\/8″ + 2× 1\/2″\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMax piping (total \/ per indoor)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e262.4 ft \/ 114.8 ft\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMax height difference\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIDU↔ODU: 49.2 ft · Between IDUs: 33 ft\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"hvx-desc-card\"\u003e\n\u003ch2 class=\"hvx-section-title\"\u003eDocuments \u0026amp; Downloads\u003c\/h2\u003e\n\u003cul style=\"padding-left: 18px; margin: 8px 0;\"\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/media.cooperandhunter.us\/4813\/CH-RVHP36M-230VO.pdf\" rel=\"noopener\" target=\"_blank\"\u003eCH-RVHP36M-230VO Submittal (PDF)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/media.cooperandhunter.us\/4811\/RVHP-Installation-manual-Multi-Zone-Units_compressed.pdf\" rel=\"noopener\" target=\"_blank\"\u003eRVHP Multi-Zone Units Installation Manual (PDF)\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp class=\"hvx-note\"\u003eAHRI certification numbers (reference): Ducted 210799635 · Non-Ducted 210799634 · Mixed 210799639.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"hvx-desc-card\"\u003e\n\u003ch2 class=\"hvx-section-title\"\u003eImportant\u003c\/h2\u003e\n\u003cp class=\"hvx-note\" style=\"font-size: 14px; color: var(--hvx-slate); margin: 0;\"\u003eInstall by a licensed HVAC professional. Confirm zone combinations, electrical requirements (187–253 V), MCA\/max-fuse, line sizes (including the 1\/2″ gas circuits), total\/branch piping limits, and ambient operating ranges (down to −22 °F) before commissioning.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"hvx-desc-card\"\u003e\n\u003ch2 class=\"hvx-section-title\"\u003eFAQs\u003c\/h2\u003e\n\u003cdetails class=\"hvx-faq\" open=\"\"\u003e\n\u003csummary\u003eHow many zones can this support?\u003c\/summary\u003e\n\u003cdiv style=\"margin-top: 8px;\"\u003eUp to five independent zones with compatible Cooper\u0026amp;Hunter multi-zone indoor units.\u003c\/div\u003e\n\u003c\/details\u003e\n\u003cdetails class=\"hvx-faq\" open=\"\"\u003e\n\u003csummary\u003eHow cold can it heat in Hyper Heat mode?\u003c\/summary\u003e\n\u003cdiv style=\"margin-top: 8px;\"\u003eHeating operation is rated down to −22 °F.\u003c\/div\u003e\n\u003c\/details\u003e\n\u003cdetails class=\"hvx-faq\" open=\"\"\u003e\n\u003csummary\u003eWhat line sizes are required?\u003c\/summary\u003e\n\u003cdiv style=\"margin-top: 8px;\"\u003eFive circuits total: 5× 1\/4″ liquid and gas connections of 3× 3\/8″ plus 2× 1\/2″.\u003c\/div\u003e\n\u003c\/details\u003e\n\u003cdetails class=\"hvx-faq\" open=\"\"\u003e\n\u003csummary\u003eWhat are the power requirements?\u003c\/summary\u003e\n\u003cdiv style=\"margin-top: 8px;\"\u003e208\/230 V, single-phase, 60 Hz. Voltage range 187–253 V. MCA 37 A. Max fuse 40 A.\u003c\/div\u003e\n\u003c\/details\u003e\n\u003cdetails class=\"hvx-faq\" open=\"\"\u003e\n\u003csummary\u003eWhat are the piping limits?\u003c\/summary\u003e\n\u003cdiv style=\"margin-top: 8px;\"\u003eUp to 262.4 ft total piping, and up to 114.8 ft for a single indoor unit run, within system design limits.\u003c\/div\u003e\n\u003c\/details\u003e\n\u003cdetails class=\"hvx-faq\" open=\"\"\u003e\n\u003csummary\u003eWhat refrigerant does it use?\u003c\/summary\u003e\n\u003cdiv style=\"margin-top: 8px;\"\u003eR454B (factory charge: 134.04 oz; precharge: 125 ft).\u003c\/div\u003e\n\u003c\/details\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e","brand":"Cooper\u0026Hunter","offers":[{"title":"Default Title","offer_id":42697734881323,"sku":"CH-RVHP36M-230VO","price":4289.0,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0625\/5647\/1339\/files\/19000BTUHYPER_1.png?v=1769188233"},{"product_id":"cooper-hunter-hyper-multi-zone-r454b-outdoor-condenser-48-000-btu-4-ton","title":"Cooper\u0026Hunter Hyper Multi-Zone R454B Outdoor Condenser 48,000 BTU (4 Ton)","description":"\u003cstyle\u003e\n  :root{\n    --hvx-golden:#FAA819;\n    --hvx-slate:#262626;\n    --hvx-ivory:#F4F1E6;\n    --hvx-border:#e2e0d5;\n    --hvx-card-bg:#ffffff;\n  }\n\n  .hvx-desc{\n    font-family:\"Articulat CF\",system-ui,-apple-system,BlinkMacSystemFont,\"Segoe UI\",sans-serif;\n    color:var(--hvx-slate);\n    line-height:1.6;\n    background:var(--hvx-ivory);\n    padding:18px 18px 20px;\n    border-radius:16px;\n  }\n\n  .hvx-desc-header{\n    border-radius:14px;\n    padding:14px 16px;\n    background:linear-gradient(120deg,var(--hvx-golden),var(--hvx-slate));\n    color:#fff;\n    margin:0 0 16px;\n    box-shadow:0 10px 24px rgba(0,0,0,.22);\n    display:flex;\n    align-items:flex-start;\n    gap:12px;\n    flex-wrap:wrap;\n  }\n\n  .hvx-header-text{display:flex;flex-direction:column;gap:4px;min-width:260px}\n  .hvx-eyebrow{\n    font-size:11px;\n    letter-spacing:.14em;\n    text-transform:uppercase;\n    opacity:.9;\n  }\n  .hvx-title{\n    margin:0;\n    font-family:\"Anton\",\"Impact\",system-ui,-apple-system,BlinkMacSystemFont,\"Segoe UI\",sans-serif;\n    font-size:22px;\n    line-height:1.15;\n  }\n\n  .hvx-desc-card{\n    border:1px solid var(--hvx-border);\n    border-radius:14px;\n    background:var(--hvx-card-bg);\n    padding:16px 18px 18px;\n    box-shadow:0 4px 12px rgba(0,0,0,.06);\n    margin:14px 0;\n  }\n\n  .hvx-section-title{\n    margin:0 0 10px;\n    font-family:\"Anton\",\"Impact\",system-ui,-apple-system,BlinkMacSystemFont,\"Segoe UI\",sans-serif;\n    font-size:17px;\n    letter-spacing:.08em;\n    text-transform:uppercase;\n    color:var(--hvx-slate);\n    display:inline-flex;\n    align-items:center;\n    gap:8px;\n  }\n  .hvx-section-title::after{\n    content:\"\";\n    flex:1;\n    height:2px;\n    border-radius:999px;\n    background:linear-gradient(90deg,var(--hvx-golden),transparent);\n    opacity:.9;\n  }\n\n  .hvx-cta{display:flex;flex-wrap:wrap;gap:10px;margin:10px 0 0}\n  .hvx-cta a{\n    display:inline-flex;\n    align-items:center;\n    gap:8px;\n    padding:10px 14px;\n    border-radius:12px;\n    border:1px solid var(--hvx-border);\n    background:#fff;\n    text-decoration:none;\n    color:var(--hvx-slate);\n    font-size:14px;\n    font-weight:700;\n  }\n  .hvx-cta a.primary{\n    background:var(--hvx-slate);\n    color:#fff;\n    border-color:transparent;\n  }\n\n  .hvx-badges{display:flex;flex-wrap:wrap;gap:8px;margin:10px 0 0}\n  .hvx-badge{\n    font-size:12px;\n    border:1px solid var(--hvx-border);\n    border-radius:999px;\n    padding:6px 10px;\n    background:#fff;\n    white-space:nowrap;\n  }\n\n  .hvx-kv{\n    display:grid;\n    grid-template-columns:repeat(4,minmax(160px,1fr));\n    gap:10px;\n    margin-top:10px;\n  }\n  .hvx-kv \u003e div{\n    border:1px solid var(--hvx-border);\n    background:#fff;\n    border-radius:12px;\n    padding:10px 12px;\n    text-align:center;\n  }\n  .hvx-kv strong{display:block}\n\n  .hvx-table{\n    width:100%;\n    border-collapse:collapse;\n    min-width:520px;\n    background:#fff;\n    border:1px solid var(--hvx-border);\n    border-radius:12px;\n    overflow:hidden;\n  }\n  .hvx-table th,.hvx-table td{\n    border-bottom:1px solid var(--hvx-border);\n    padding:10px 12px;\n    vertical-align:top;\n    font-size:14px;\n  }\n  .hvx-table th{ text-align:left; font-weight:800; background:#fff; }\n  .hvx-table tr:nth-child(odd) td{ background:#fff; }\n  .hvx-table tr:nth-child(even) td{ background:#fbfaf6; }\n  .hvx-table tr:last-child td{ border-bottom:none; }\n  .hvx-table-wrap{ overflow:auto; border-radius:12px; }\n\n  .hvx-note{\n    font-size:12px;\n    color:#555;\n    margin:10px 0 0;\n  }\n\n  details.hvx-faq{\n    border:1px solid var(--hvx-border);\n    background:#fff;\n    border-radius:12px;\n    padding:10px 12px;\n    margin:8px 0;\n  }\n  details.hvx-faq summary{\n    cursor:pointer;\n    font-weight:800;\n  }\n\n  @media(max-width:980px){\n    .hvx-kv{grid-template-columns:repeat(2,minmax(160px,1fr))}\n  }\n  @media(max-width:768px){\n    .hvx-desc{padding:14px 12px 16px;border-radius:12px}\n    .hvx-desc-header{padding:12px;border-radius:12px}\n    .hvx-title{font-size:19px}\n    .hvx-desc-card{padding:14px;margin:10px 0}\n  }\n\u003c\/style\u003e\n\u003cdiv class=\"hvx-desc\"\u003e\n\u003cdiv class=\"hvx-desc-header\"\u003e\n\u003cdiv class=\"hvx-header-text\"\u003e\n\u003cdiv class=\"hvx-eyebrow\"\u003eCooper\u0026amp;Hunter Hyper Heat Multi-Zone Outdoor • R454B • Up to 6 Zones\u003c\/div\u003e\n\u003ch1 class=\"hvx-title\"\u003eCooper\u0026amp;Hunter Hyper Heat Multi-Zone Outdoor — 48,000 BTU, R454B — CH-RVHP48M-230VO\u003c\/h1\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"hvx-cta\" aria-label=\"Contact options\"\u003e\n\u003ca class=\"primary\" href=\"https:\/\/hvacsupplies.com\/pages\/contact\" rel=\"noopener\" title=\"Contact Us\" target=\"_blank\"\u003e CLICK HERE TO CONTACT US FOR CUSTOM QUOTES AND QUESTIONS \u003c\/a\u003e \u003ca href=\"tel:+18005438933\" title=\"Call Us Now!\"\u003e CLICK TO CALL US 1-800-543-8933 FOR ANY QUESTIONS \u003c\/a\u003e \u003cbr\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"hvx-desc-card\"\u003e\n\u003ch2 class=\"hvx-section-title\"\u003eOverview\u003c\/h2\u003e\n\u003cp style=\"margin: 0;\"\u003eCooper\u0026amp;Hunter’s 48K BTU Hyper Heat Multi-Zone outdoor unit is built for large residential and light commercial applications that need flexible, room-by-room control. It supports up to six zones with independent temperature settings and includes Hyper Heating technology for reliable performance in extreme cold, with heating operation rated down to −22 °F. Advanced inverter technology modulates compressor speed to match connected-zone demand, delivering strong efficiency (up to 23 SEER2) and consistent comfort. Using R454B refrigerant (lower GWP vs. many conventional options), it supports modern, eco-conscious system designs.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"hvx-desc-card\"\u003e\n\u003ch2 class=\"hvx-section-title\"\u003eHighlights\u003c\/h2\u003e\n\u003cdiv class=\"hvx-badges\" role=\"list\"\u003e\n\u003cspan class=\"hvx-badge\" role=\"listitem\"\u003eUp to 6 zones\u003c\/span\u003e \u003cspan class=\"hvx-badge\" role=\"listitem\"\u003eSEER2 23 · EER2 12\u003c\/span\u003e \u003cspan class=\"hvx-badge\" role=\"listitem\"\u003eHSPF 11 (Region IV) · 9 (Region V)\u003c\/span\u003e \u003cspan class=\"hvx-badge\" role=\"listitem\"\u003eCOP 3.7 @ 47 °F\u003c\/span\u003e \u003cspan class=\"hvx-badge\" role=\"listitem\"\u003eHyper Heat to −22 °F\u003c\/span\u003e \u003cspan class=\"hvx-badge\" role=\"listitem\"\u003eR454B\u003c\/span\u003e \u003cspan class=\"hvx-badge\" role=\"listitem\"\u003e208–230V 1Ph\u003c\/span\u003e \u003cspan class=\"hvx-badge\" role=\"listitem\"\u003eMax total piping 262.4 ft\u003c\/span\u003e\n\u003c\/div\u003e\n\u003cul style=\"margin: 12px 0 0; padding-left: 18px;\"\u003e\n\u003cli\u003e\n\u003cstrong\u003eSix-zone flexibility:\u003c\/strong\u003e supports up to six independent zones with compatible indoor units.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCold-climate heating:\u003c\/strong\u003e heating operation rated down to −22 °F.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEnergy smart:\u003c\/strong\u003e inverter-driven operation with up to 23 SEER2 efficiency.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEco-forward refrigerant:\u003c\/strong\u003e R454B helps reduce environmental impact.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHigh-capacity comfort:\u003c\/strong\u003e designed for large layouts and multi-room applications.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cdiv class=\"hvx-kv\" role=\"list\" aria-label=\"At-a-glance\"\u003e\n\u003cdiv role=\"listitem\"\u003e\n\u003cstrong\u003eModel\u003c\/strong\u003eCH-RVHP48M-230VO\u003c\/div\u003e\n\u003cdiv role=\"listitem\"\u003e\n\u003cstrong\u003eZones\u003c\/strong\u003eUp to 6\u003c\/div\u003e\n\u003cdiv role=\"listitem\"\u003e\n\u003cstrong\u003eOutdoor Sound\u003c\/strong\u003e65 dB(A)\u003c\/div\u003e\n\u003cdiv role=\"listitem\"\u003e\n\u003cstrong\u003eLines\u003c\/strong\u003e6× 1\/4″ liquid · (4× 3\/8″ + 2× 1\/2″) gas\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"hvx-desc-card\"\u003e\n\u003ch2 class=\"hvx-section-title\"\u003eWhat's Included\u003c\/h2\u003e\n\u003cul style=\"padding-left: 18px; margin: 8px 0;\"\u003e\n\u003cli\u003eOutdoor unit CH-RVHP48M-230VO\u003c\/li\u003e\n\u003cli\u003eOwner \/ installation documentation\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp class=\"hvx-note\"\u003ePair only with compatible Cooper\u0026amp;Hunter multi-zone indoor units. Confirm zone combinations, piping, and length limits before installation.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"hvx-desc-card\"\u003e\n\u003ch2 class=\"hvx-section-title\"\u003eIndoor Specs\u003c\/h2\u003e\n\u003cdiv class=\"hvx-table-wrap\"\u003e\n\u003ctable class=\"hvx-table\" aria-label=\"Indoor unit compatibility\"\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eSpec\u003c\/th\u003e\n\u003cth\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSystem type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eHyper Heat multi-zone outdoor unit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eZones supported\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eUp to 6 independent zones (depends on indoor unit selection)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRefrigerant piping\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e6 circuits: 6× 1\/4″ liquid · gas connections are 4× 3\/8″ + 2× 1\/2″\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMax total pipe length\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e262.4 ft\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMax length per indoor unit\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e114.8 ft\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMax height difference (IDU↔ODU)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e49.2 ft\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMax height difference (between indoor units)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e33 ft\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCombination guidance\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eConfirm indoor unit mixes per the applicable submittal documentation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003cp class=\"hvx-note\"\u003eIndoor-unit capacities, controls, and features depend on the specific indoor models selected for each zone.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"hvx-desc-card\"\u003e\n\u003ch2 class=\"hvx-section-title\"\u003eOutdoor Specs\u003c\/h2\u003e\n\u003cdiv class=\"hvx-table-wrap\"\u003e\n\u003ctable class=\"hvx-table\" aria-label=\"Outdoor unit specifications\"\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eSpec\u003c\/th\u003e\n\u003cth\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCH-RVHP48M-230VO\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e208\/230 V, 1-Phase, 60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eVoltage range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e187–253 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCooling capacity (range)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e12,000–57,000 BTU\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCooling current (rated)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e17.3 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSEER2 \/ EER2\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e23 \/ 12\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eHeating capacity @ 47 °F (range)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e13,000–57,000 BTU\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eHeating current @ 47 °F (rated)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e17.3 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCOP @ 47 °F\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3.7 W\/W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eHSPF (Region IV \/ V)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e11 \/ 9\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eHeating capacity @ 5 °F (rated)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e47,000 BTU\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMCA \/ Max fuse\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e37 A \/ 40 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOutdoor airflow (max)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4,502.8 CFM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOutdoor sound\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e65 dB(A)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eUnit size (W×D×H)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e37.48 × 16.34 × 52.48 in\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePacking size (W×D×H)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e43.11 × 19.49 × 58.27 in\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNet \/ Gross weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e246.47 \/ 276.68 lb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRefrigerant \/ Charge\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eR454B \/ 151.68 oz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFactory precharge\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e150 ft\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAdditional refrigerant charge\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.16 oz\/ft\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDesign pressure\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e550 \/ 340 PSIG\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAmbient range (cool \/ heat)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e−22–122 °F \/ −22–75 °F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eLine sizes\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eLiquid: 6× 1\/4″ · Gas: 4× 3\/8″ + 2× 1\/2″\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMax piping (total \/ per indoor)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e262.4 ft \/ 114.8 ft\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMax height difference\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIDU↔ODU: 49.2 ft · Between IDUs: 33 ft\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003cp class=\"hvx-note\"\u003eAHRI certification (reference): 207740529.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"hvx-desc-card\"\u003e\n\u003ch2 class=\"hvx-section-title\"\u003eDocuments \u0026amp; Downloads\u003c\/h2\u003e\n\u003cul style=\"padding-left: 18px; margin: 8px 0;\"\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/media.cooperandhunter.us\/4816\/CH-RVHP48M-230VO.pdf\" rel=\"noopener\" target=\"_blank\"\u003eCH-RVHP48M-230VO Submittal (PDF)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/media.cooperandhunter.us\/4811\/RVHP-Installation-manual-Multi-Zone-Units_compressed.pdf\" rel=\"noopener\" target=\"_blank\"\u003eRVHP Multi-Zone Units Installation Manual (PDF)\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"hvx-desc-card\"\u003e\n\u003ch2 class=\"hvx-section-title\"\u003eImportant\u003c\/h2\u003e\n\u003cp class=\"hvx-note\" style=\"font-size: 14px; color: var(--hvx-slate); margin: 0;\"\u003eInstall by a licensed HVAC professional. Confirm zone combinations, electrical requirements (187–253 V), MCA\/max-fuse, line sizes (including the 1\/2″ gas circuits), total\/branch piping limits, and ambient operating ranges (down to −22 °F) before commissioning.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"hvx-desc-card\"\u003e\n\u003ch2 class=\"hvx-section-title\"\u003eFAQs\u003c\/h2\u003e\n\u003cdetails class=\"hvx-faq\" open=\"\"\u003e\n\u003csummary\u003eHow many zones can this support?\u003c\/summary\u003e\n\u003cdiv style=\"margin-top: 8px;\"\u003eUp to six independent zones with compatible Cooper\u0026amp;Hunter multi-zone indoor units.\u003c\/div\u003e\n\u003c\/details\u003e\n\u003cdetails class=\"hvx-faq\" open=\"\"\u003e\n\u003csummary\u003eHow cold can it heat in Hyper Heat mode?\u003c\/summary\u003e\n\u003cdiv style=\"margin-top: 8px;\"\u003eHeating operation is rated down to −22 °F.\u003c\/div\u003e\n\u003c\/details\u003e\n\u003cdetails class=\"hvx-faq\" open=\"\"\u003e\n\u003csummary\u003eWhat line sizes are required?\u003c\/summary\u003e\n\u003cdiv style=\"margin-top: 8px;\"\u003eSix circuits total: 6× 1\/4″ liquid and gas connections of 4× 3\/8″ plus 2× 1\/2″.\u003c\/div\u003e\n\u003c\/details\u003e\n\u003cdetails class=\"hvx-faq\" open=\"\"\u003e\n\u003csummary\u003eWhat are the power requirements?\u003c\/summary\u003e\n\u003cdiv style=\"margin-top: 8px;\"\u003e208\/230 V, single-phase, 60 Hz. Voltage range 187–253 V. MCA 37 A. Max fuse 40 A.\u003c\/div\u003e\n\u003c\/details\u003e\n\u003cdetails class=\"hvx-faq\" open=\"\"\u003e\n\u003csummary\u003eWhat are the piping limits?\u003c\/summary\u003e\n\u003cdiv style=\"margin-top: 8px;\"\u003eUp to 262.4 ft total piping, and up to 114.8 ft for a single indoor unit run, within system design limits.\u003c\/div\u003e\n\u003c\/details\u003e\n\u003cdetails class=\"hvx-faq\" open=\"\"\u003e\n\u003csummary\u003eWhat refrigerant does it use?\u003c\/summary\u003e\n\u003cdiv style=\"margin-top: 8px;\"\u003eR454B (factory charge: 151.68 oz; precharge: 150 ft).\u003c\/div\u003e\n\u003c\/details\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e","brand":"Cooper\u0026Hunter","offers":[{"title":"Default Title","offer_id":42697738125355,"sku":"CH-RVHP48M-230VO","price":5424.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0625\/5647\/1339\/files\/55000_BTU_HYPER_9df2e579-492c-4fdf-8e18-2e326b02bc86.png?v=1769188160"},{"product_id":"cooper-hunter-hyper-multi-zone-r454b-outdoor-condenser-55-000-btu-4-5-ton","title":"Cooper\u0026Hunter Hyper Multi-Zone R454B Outdoor Condenser 55,000 BTU (4.5 Ton)","description":"\u003cstyle\u003e\n  :root{\n    --hvx-golden:#FAA819;\n    --hvx-slate:#262626;\n    --hvx-ivory:#F4F1E6;\n    --hvx-border:#e2e0d5;\n    --hvx-card-bg:#ffffff;\n  }\n\n  .hvx-desc{\n    font-family:\"Articulat CF\",system-ui,-apple-system,BlinkMacSystemFont,\"Segoe UI\",sans-serif;\n    color:var(--hvx-slate);\n    line-height:1.6;\n    background:var(--hvx-ivory);\n    padding:18px 18px 20px;\n    border-radius:16px;\n  }\n\n  .hvx-desc-header{\n    border-radius:14px;\n    padding:14px 16px;\n    background:linear-gradient(120deg,var(--hvx-golden),var(--hvx-slate));\n    color:#fff;\n    margin:0 0 16px;\n    box-shadow:0 10px 24px rgba(0,0,0,.22);\n    display:flex;\n    align-items:flex-start;\n    gap:12px;\n    flex-wrap:wrap;\n  }\n\n  .hvx-header-text{display:flex;flex-direction:column;gap:4px;min-width:260px}\n  .hvx-eyebrow{\n    font-size:11px;\n    letter-spacing:.14em;\n    text-transform:uppercase;\n    opacity:.9;\n  }\n  .hvx-title{\n    margin:0;\n    font-family:\"Anton\",\"Impact\",system-ui,-apple-system,BlinkMacSystemFont,\"Segoe UI\",sans-serif;\n    font-size:22px;\n    line-height:1.15;\n  }\n\n  .hvx-desc-card{\n    border:1px solid var(--hvx-border);\n    border-radius:14px;\n    background:var(--hvx-card-bg);\n    padding:16px 18px 18px;\n    box-shadow:0 4px 12px rgba(0,0,0,.06);\n    margin:14px 0;\n  }\n\n  .hvx-section-title{\n    margin:0 0 10px;\n    font-family:\"Anton\",\"Impact\",system-ui,-apple-system,BlinkMacSystemFont,\"Segoe UI\",sans-serif;\n    font-size:17px;\n    letter-spacing:.08em;\n    text-transform:uppercase;\n    color:var(--hvx-slate);\n    display:inline-flex;\n    align-items:center;\n    gap:8px;\n  }\n  .hvx-section-title::after{\n    content:\"\";\n    flex:1;\n    height:2px;\n    border-radius:999px;\n    background:linear-gradient(90deg,var(--hvx-golden),transparent);\n    opacity:.9;\n  }\n\n  .hvx-cta{display:flex;flex-wrap:wrap;gap:10px;margin:10px 0 0}\n  .hvx-cta a{\n    display:inline-flex;\n    align-items:center;\n    gap:8px;\n    padding:10px 14px;\n    border-radius:12px;\n    border:1px solid var(--hvx-border);\n    background:#fff;\n    text-decoration:none;\n    color:var(--hvx-slate);\n    font-size:14px;\n    font-weight:700;\n  }\n  .hvx-cta a.primary{\n    background:var(--hvx-slate);\n    color:#fff;\n    border-color:transparent;\n  }\n\n  .hvx-badges{display:flex;flex-wrap:wrap;gap:8px;margin:10px 0 0}\n  .hvx-badge{\n    font-size:12px;\n    border:1px solid var(--hvx-border);\n    border-radius:999px;\n    padding:6px 10px;\n    background:#fff;\n    white-space:nowrap;\n  }\n\n  .hvx-kv{\n    display:grid;\n    grid-template-columns:repeat(4,minmax(160px,1fr));\n    gap:10px;\n    margin-top:10px;\n  }\n  .hvx-kv \u003e div{\n    border:1px solid var(--hvx-border);\n    background:#fff;\n    border-radius:12px;\n    padding:10px 12px;\n    text-align:center;\n  }\n  .hvx-kv strong{display:block}\n\n  .hvx-table{\n    width:100%;\n    border-collapse:collapse;\n    min-width:520px;\n    background:#fff;\n    border:1px solid var(--hvx-border);\n    border-radius:12px;\n    overflow:hidden;\n  }\n  .hvx-table th,.hvx-table td{\n    border-bottom:1px solid var(--hvx-border);\n    padding:10px 12px;\n    vertical-align:top;\n    font-size:14px;\n  }\n  .hvx-table th{ text-align:left; font-weight:800; background:#fff; }\n  .hvx-table tr:nth-child(odd) td{ background:#fff; }\n  .hvx-table tr:nth-child(even) td{ background:#fbfaf6; }\n  .hvx-table tr:last-child td{ border-bottom:none; }\n  .hvx-table-wrap{ overflow:auto; border-radius:12px; }\n\n  .hvx-note{\n    font-size:12px;\n    color:#555;\n    margin:10px 0 0;\n  }\n\n  details.hvx-faq{\n    border:1px solid var(--hvx-border);\n    background:#fff;\n    border-radius:12px;\n    padding:10px 12px;\n    margin:8px 0;\n  }\n  details.hvx-faq summary{\n    cursor:pointer;\n    font-weight:800;\n  }\n\n  @media(max-width:980px){\n    .hvx-kv{grid-template-columns:repeat(2,minmax(160px,1fr))}\n  }\n  @media(max-width:768px){\n    .hvx-desc{padding:14px 12px 16px;border-radius:12px}\n    .hvx-desc-header{padding:12px;border-radius:12px}\n    .hvx-title{font-size:19px}\n    .hvx-desc-card{padding:14px;margin:10px 0}\n  }\n\u003c\/style\u003e\n\u003cdiv class=\"hvx-desc\"\u003e\n\u003cdiv class=\"hvx-desc-header\"\u003e\n\u003cdiv class=\"hvx-header-text\"\u003e\n\u003cdiv class=\"hvx-eyebrow\"\u003eCooper\u0026amp;Hunter Hyper Heat Multi-Zone Outdoor • R454B • Up to 6 Zones\u003c\/div\u003e\n\u003ch1 class=\"hvx-title\"\u003eCooper\u0026amp;Hunter Hyper Heat Multi-Zone Outdoor — 55,000 BTU, R454B — CH-RVHP55M-230VO\u003c\/h1\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"hvx-cta\" aria-label=\"Contact options\"\u003e\n\u003ca class=\"primary\" href=\"https:\/\/hvacsupplies.com\/pages\/contact\" rel=\"noopener\" title=\"Contact Us\" target=\"_blank\"\u003e CLICK HERE TO CONTACT US FOR CUSTOM QUOTES AND QUESTIONS \u003c\/a\u003e \u003ca href=\"tel:+18005438933\" title=\"Call Us Now!\"\u003e CLICK TO CALL US 1-800-543-8933 FOR ANY QUESTIONS \u003c\/a\u003e \u003cbr\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"hvx-desc-card\"\u003e\n\u003ch2 class=\"hvx-section-title\"\u003eOverview\u003c\/h2\u003e\n\u003cp style=\"margin: 0;\"\u003eCooper\u0026amp;Hunter’s 55K BTU Hyper Heat Multi-Zone outdoor unit is engineered for expansive residential spaces that need precise, room-by-room comfort. It supports up to six zones with independent temperature control and features Hyper Heating technology for strong cold-weather operation, with heating rated down to −22 °F. Advanced inverter technology dynamically adjusts compressor activity to align with real-time demand for efficient, consistent performance. With up to 22.2 SEER2 efficiency and R454B refrigerant (lower GWP vs. many conventional options), it’s a modern solution focused on comfort, efficiency, and sustainability.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"hvx-desc-card\"\u003e\n\u003ch2 class=\"hvx-section-title\"\u003eHighlights\u003c\/h2\u003e\n\u003cdiv class=\"hvx-badges\" role=\"list\"\u003e\n\u003cspan class=\"hvx-badge\" role=\"listitem\"\u003eUp to 6 zones\u003c\/span\u003e \u003cspan class=\"hvx-badge\" role=\"listitem\"\u003eSEER2 22.2 · EER2 12\u003c\/span\u003e \u003cspan class=\"hvx-badge\" role=\"listitem\"\u003eHSPF2 10.5 (Region IV) · 8.5 (Region V)\u003c\/span\u003e \u003cspan class=\"hvx-badge\" role=\"listitem\"\u003eCOP 3.5\u003c\/span\u003e \u003cspan class=\"hvx-badge\" role=\"listitem\"\u003eHyper Heat to −22 °F\u003c\/span\u003e \u003cspan class=\"hvx-badge\" role=\"listitem\"\u003eR454B\u003c\/span\u003e \u003cspan class=\"hvx-badge\" role=\"listitem\"\u003e208–230V 1Ph\u003c\/span\u003e \u003cspan class=\"hvx-badge\" role=\"listitem\"\u003e187–253 V range\u003c\/span\u003e\n\u003c\/div\u003e\n\u003cul style=\"margin: 12px 0 0; padding-left: 18px;\"\u003e\n\u003cli\u003e\n\u003cstrong\u003eSix-zone control:\u003c\/strong\u003e supports up to six independent zones with compatible indoor units.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eExtreme cold heating:\u003c\/strong\u003e Hyper Heat operation rated down to −22 °F.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEnergy efficient:\u003c\/strong\u003e up to 22.2 SEER2 with inverter-driven performance.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEco-forward refrigerant:\u003c\/strong\u003e R454B helps reduce environmental impact.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHigh capacity:\u003c\/strong\u003e built for large, multi-room layouts requiring steady comfort.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cdiv class=\"hvx-kv\" role=\"list\" aria-label=\"At-a-glance\"\u003e\n\u003cdiv role=\"listitem\"\u003e\n\u003cstrong\u003eModel\u003c\/strong\u003eCH-RVHP55M-230VO\u003c\/div\u003e\n\u003cdiv role=\"listitem\"\u003e\n\u003cstrong\u003eZones\u003c\/strong\u003eUp to 6\u003c\/div\u003e\n\u003cdiv role=\"listitem\"\u003e\n\u003cstrong\u003eOutdoor Sound\u003c\/strong\u003e65 dB(A)\u003c\/div\u003e\n\u003cdiv role=\"listitem\"\u003e\n\u003cstrong\u003eLines\u003c\/strong\u003e6× 1\/4″ liquid · (4× 3\/8″ + 2× 1\/2″) gas\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"hvx-desc-card\"\u003e\n\u003ch2 class=\"hvx-section-title\"\u003eWhat's Included\u003c\/h2\u003e\n\u003cul style=\"padding-left: 18px; margin: 8px 0;\"\u003e\n\u003cli\u003eOutdoor unit CH-RVHP55M-230VO\u003c\/li\u003e\n\u003cli\u003eOwner \/ installation documentation\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp class=\"hvx-note\"\u003ePair only with compatible Cooper\u0026amp;Hunter multi-zone indoor units. Confirm indoor mixes, electrical, and piping requirements before installation.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"hvx-desc-card\"\u003e\n\u003ch2 class=\"hvx-section-title\"\u003eIndoor Specs\u003c\/h2\u003e\n\u003cdiv class=\"hvx-table-wrap\"\u003e\n\u003ctable class=\"hvx-table\" aria-label=\"Indoor unit compatibility\"\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eSpec\u003c\/th\u003e\n\u003cth\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSystem type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eHyper Heat multi-zone outdoor unit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eZones supported\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eUp to 6 independent zones (depends on indoor unit selection)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRefrigerant piping\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e6 circuits: 6× 1\/4″ liquid · gas connections are 4× 3\/8″ + 2× 1\/2″\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eHeight difference (IDU↔ODU)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eUp to 49.2 ft\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCombination guidance\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eConfirm indoor unit mixes per the applicable submittal documentation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003cp class=\"hvx-note\"\u003eIndoor-unit capacities, controls, and features depend on the specific indoor models selected for each zone.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"hvx-desc-card\"\u003e\n\u003ch2 class=\"hvx-section-title\"\u003eOutdoor Specs\u003c\/h2\u003e\n\u003cdiv class=\"hvx-table-wrap\"\u003e\n\u003ctable class=\"hvx-table\" aria-label=\"Outdoor unit specifications\"\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eSpec\u003c\/th\u003e\n\u003cth\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCH-RVHP55M-230VO\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePerformance level\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eHyper Heat\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e208–230 V, 1-Phase, 60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eVoltage range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e187–253 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCooling capacity (min\/max)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e51,000 (19,000–59,000) BTU\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSEER2 \/ EER2\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e22.2 \/ 12\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eHeating capacity (min\/max)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e55,000 (20,000–59,000) BTU\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCOP\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3.5 W\/W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eHSPF2 (Region IV \/ V)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e10.5 \/ 8.5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMCA \/ Max fuse\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e39.5 A \/ 40 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOutdoor airflow\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4,502.8 CFM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOutdoor sound\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e65 dB(A)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eUnit size (W×H×D)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e37.48 × 52.48 × 16.34 in\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePacking size (W×D×H)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e43.11 × 19.49 × 58.27 in\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNet \/ Gross weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e246.47 \/ 276.68 lb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRefrigerant\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eR454B\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFactory precharge\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e150 ft\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAmbient range (cool \/ heat)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e−22–122 °F \/ −22–75 °F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eLine sizes\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eLiquid: 6× 1\/4″ · Gas: 4× 3\/8″ + 2× 1\/2″\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003cp class=\"hvx-note\"\u003eAHRI certification numbers (reference): Ducted 215864281 · Non-Ducted 215864282 · Mixed 215864283.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"hvx-desc-card\"\u003e\n\u003ch2 class=\"hvx-section-title\"\u003eDocuments \u0026amp; Downloads\u003c\/h2\u003e\n\u003cul style=\"padding-left: 18px; margin: 8px 0;\"\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/media.cooperandhunter.us\/4829\/CH-RVHP55M-230VO.pdf\" rel=\"noopener\" target=\"_blank\"\u003eCH-RVHP55M-230VO Submittal (PDF)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/media.cooperandhunter.us\/4811\/RVHP-Installation-manual-Multi-Zone-Units_compressed.pdf\" rel=\"noopener\" target=\"_blank\"\u003eRVHP Multi-Zone Units Installation Manual (PDF)\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"hvx-desc-card\"\u003e\n\u003ch2 class=\"hvx-section-title\"\u003eImportant\u003c\/h2\u003e\n\u003cp class=\"hvx-note\" style=\"font-size: 14px; color: var(--hvx-slate); margin: 0;\"\u003eInstall by a licensed HVAC professional. Confirm indoor unit combinations, electrical requirements (187–253 V), MCA\/max-fuse, line sizes, refrigerant precharge\/field charging requirements, and ambient operating ranges (down to −22 °F) before commissioning.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"hvx-desc-card\"\u003e\n\u003ch2 class=\"hvx-section-title\"\u003eFAQs\u003c\/h2\u003e\n\u003cdetails class=\"hvx-faq\" open=\"\"\u003e\n\u003csummary\u003eHow many zones can this support?\u003c\/summary\u003e\n\u003cdiv style=\"margin-top: 8px;\"\u003eUp to six independent zones with compatible Cooper\u0026amp;Hunter multi-zone indoor units.\u003c\/div\u003e\n\u003c\/details\u003e\n\u003cdetails class=\"hvx-faq\" open=\"\"\u003e\n\u003csummary\u003eHow cold can it heat in Hyper Heat mode?\u003c\/summary\u003e\n\u003cdiv style=\"margin-top: 8px;\"\u003eHeating operation is rated down to −22 °F.\u003c\/div\u003e\n\u003c\/details\u003e\n\u003cdetails class=\"hvx-faq\" open=\"\"\u003e\n\u003csummary\u003eWhat are the power requirements?\u003c\/summary\u003e\n\u003cdiv style=\"margin-top: 8px;\"\u003e208–230 V, single-phase, 60 Hz. Voltage range 187–253 V. MCA 39.5 A. Max fuse 40 A.\u003c\/div\u003e\n\u003c\/details\u003e\n\u003cdetails class=\"hvx-faq\" open=\"\"\u003e\n\u003csummary\u003eWhat line sizes are required?\u003c\/summary\u003e\n\u003cdiv style=\"margin-top: 8px;\"\u003eSix circuits total: 6× 1\/4″ liquid and gas connections of 4× 3\/8″ plus 2× 1\/2″.\u003c\/div\u003e\n\u003c\/details\u003e\n\u003cdetails class=\"hvx-faq\" open=\"\"\u003e\n\u003csummary\u003eWhat refrigerant does it use?\u003c\/summary\u003e\n\u003cdiv style=\"margin-top: 8px;\"\u003eR454B (factory precharge: 150 ft).\u003c\/div\u003e\n\u003c\/details\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e","brand":"Cooper\u0026Hunter","offers":[{"title":"Default Title","offer_id":42697741926443,"sku":"CH-RVHP55M-230VO","price":6103.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0625\/5647\/1339\/files\/55000_BTU_HYPER_9df2e579-492c-4fdf-8e18-2e326b02bc86.png?v=1769188160"},{"product_id":"cooper-hunte-hyper-multi-zone-r410a-outdoor-condenser-19-000-btu-1-58-ton","title":"Cooper\u0026Hunte Hyper Multi-Zone R410A Outdoor Condenser 19,000 BTU (1.58 Ton)","description":"\u003cstyle\u003e\n  :root{\n    --hvx-golden:#FAA819;\n    --hvx-slate:#262626;\n    --hvx-ivory:#F4F1E6;\n    --hvx-border:#e2e0d5;\n    --hvx-card-bg:#ffffff;\n  }\n\n  .hvx-desc{\n    font-family:\"Articulat CF\",system-ui,-apple-system,BlinkMacSystemFont,\"Segoe UI\",sans-serif;\n    color:var(--hvx-slate);\n    line-height:1.6;\n    background:var(--hvx-ivory);\n    padding:18px 18px 20px;\n    border-radius:16px;\n  }\n\n  .hvx-desc-header{\n    border-radius:14px;\n    padding:14px 16px;\n    background:linear-gradient(120deg,var(--hvx-golden),var(--hvx-slate));\n    color:#fff;\n    margin:0 0 16px;\n    box-shadow:0 10px 24px rgba(0,0,0,.22);\n    display:flex;\n    align-items:flex-start;\n    gap:12px;\n    flex-wrap:wrap;\n  }\n\n  .hvx-header-text{display:flex;flex-direction:column;gap:6px;min-width:260px}\n  .hvx-eyebrow{\n    font-size:11px;\n    letter-spacing:.14em;\n    text-transform:uppercase;\n    opacity:.9;\n  }\n  .hvx-title{\n    margin:0;\n    font-family:\"Anton\",\"Impact\",system-ui,-apple-system,BlinkMacSystemFont,\"Segoe UI\",sans-serif;\n    font-size:22px;\n    line-height:1.15;\n  }\n  .hvx-subtitle{\n    margin:0;\n    font-size:14px;\n    opacity:.95;\n  }\n\n  .hvx-desc-card{\n    border:1px solid var(--hvx-border);\n    border-radius:14px;\n    background:var(--hvx-card-bg);\n    padding:16px 18px 18px;\n    box-shadow:0 4px 12px rgba(0,0,0,.06);\n    margin:14px 0;\n  }\n\n  .hvx-section-title{\n    margin:0 0 10px;\n    font-family:\"Anton\",\"Impact\",system-ui,-apple-system,BlinkMacSystemFont,\"Segoe UI\",sans-serif;\n    font-size:17px;\n    letter-spacing:.08em;\n    text-transform:uppercase;\n    color:var(--hvx-slate);\n    display:inline-flex;\n    align-items:center;\n    gap:8px;\n  }\n  .hvx-section-title::after{\n    content:\"\";\n    flex:1;\n    height:2px;\n    border-radius:999px;\n    background:linear-gradient(90deg,var(--hvx-golden),transparent);\n    opacity:.9;\n  }\n\n  .hvx-cta{display:flex;flex-wrap:wrap;gap:10px;margin:10px 0 0}\n  .hvx-cta a{\n    display:inline-flex;\n    align-items:center;\n    gap:8px;\n    padding:10px 14px;\n    border-radius:12px;\n    border:1px solid var(--hvx-border);\n    background:#fff;\n    text-decoration:none;\n    color:var(--hvx-slate);\n    font-size:14px;\n    font-weight:700;\n  }\n  .hvx-cta a.primary{\n    background:var(--hvx-slate);\n    color:#fff;\n    border-color:transparent;\n  }\n\n  .hvx-badges{display:flex;flex-wrap:wrap;gap:8px;margin:10px 0 0}\n  .hvx-badge{\n    font-size:12px;\n    border:1px solid var(--hvx-border);\n    border-radius:999px;\n    padding:6px 10px;\n    background:#fff;\n    white-space:nowrap;\n  }\n\n  .hvx-kv{\n    display:grid;\n    grid-template-columns:repeat(4,minmax(160px,1fr));\n    gap:10px;\n    margin-top:10px;\n  }\n  .hvx-kv \u003e div{\n    border:1px solid var(--hvx-border);\n    background:#fff;\n    border-radius:12px;\n    padding:10px 12px;\n    text-align:center;\n  }\n  .hvx-kv strong{display:block}\n\n  .hvx-table{\n    width:100%;\n    border-collapse:collapse;\n    min-width:520px;\n    background:#fff;\n    border:1px solid var(--hvx-border);\n    border-radius:12px;\n    overflow:hidden;\n  }\n  .hvx-table th,.hvx-table td{\n    border-bottom:1px solid var(--hvx-border);\n    padding:10px 12px;\n    vertical-align:top;\n    font-size:14px;\n  }\n  .hvx-table th{ text-align:left; font-weight:800; background:#fff; }\n  .hvx-table tr:nth-child(even) td{ background:#fbfaf6; }\n  .hvx-table tr:last-child td{ border-bottom:none; }\n  .hvx-table-wrap{ overflow:auto; border-radius:12px; }\n\n  .hvx-link{color:var(--hvx-slate); text-decoration:underline; text-underline-offset:2px}\n  .hvx-link:hover{opacity:.85}\n\n  details.hvx-faq{\n    border:1px solid var(--hvx-border);\n    background:#fff;\n    border-radius:12px;\n    padding:10px 12px;\n    margin:8px 0;\n  }\n  details.hvx-faq summary{cursor:pointer;font-weight:800;}\n\n  @media(max-width:980px){\n    .hvx-kv{grid-template-columns:repeat(2,minmax(160px,1fr))}\n  }\n  @media(max-width:768px){\n    .hvx-desc{padding:14px 12px 16px;border-radius:12px}\n    .hvx-desc-header{padding:12px;border-radius:12px}\n    .hvx-title{font-size:19px}\n    .hvx-desc-card{padding:14px;margin:10px 0}\n  }\n\u003c\/style\u003e\n\n\u003cdiv class=\"hvx-desc\"\u003e\n  \u003cdiv class=\"hvx-desc-header\"\u003e\n    \u003cdiv class=\"hvx-header-text\"\u003e\n      \u003cdiv class=\"hvx-eyebrow\"\u003eCooper\u0026amp;Hunter Hyper Multi-Zone Outdoor Condenser • R410A • 230V\u003c\/div\u003e\n      \u003ch1 class=\"hvx-title\"\u003eCooper\u0026amp;Hunter Hyper Multi-Zone Outdoor Condenser — 19,000 BTU (1.58 Ton) • CH-HPR19M-230VO\u003c\/h1\u003e\n      \u003cp class=\"hvx-subtitle\"\u003eHyper multi-zone condenser with extended low-ambient heating down to -22°F and up to 22 SEER2 (system dependent).\u003c\/p\u003e\n    \u003c\/div\u003e\n  \u003c\/div\u003e\n\n  \u003cdiv class=\"hvx-cta\" aria-label=\"Contact options\"\u003e\n    \u003ca class=\"primary\" href=\"https:\/\/hvacsupplies.com\/pages\/contact\" rel=\"noopener\" title=\"Contact Us\" target=\"_blank\"\u003eCLICK HERE TO CONTACT US FOR CUSTOM QUOTES AND QUESTIONS\u003c\/a\u003e\n    \u003ca href=\"tel:+18005438933\" title=\"Call Us Now!\"\u003eCLICK TO CALL US 1-800-543-8933 FOR ANY QUESTIONS\u003c\/a\u003e\n  \u003c\/div\u003e\n\n  \u003cdiv class=\"hvx-desc-card\"\u003e\n    \u003ch2 class=\"hvx-section-title\"\u003eOverview\u003c\/h2\u003e\n    \u003cp style=\"margin:0;\"\u003e\n      The \u003cstrong\u003eCH-HPR19M-230VO\u003c\/strong\u003e is a \u003cstrong\u003eHyper\u003c\/strong\u003e \u003cstrong\u003emulti-zone\u003c\/strong\u003e outdoor condenser designed for R410A systems on\n      \u003cstrong\u003e208–230V\u003c\/strong\u003e power. It is rated at \u003cstrong\u003e19,000 BTU\u003c\/strong\u003e (1.58 ton) and supports total piping up to \u003cstrong\u003e131 ft\u003c\/strong\u003e\n      with factory refrigerant precharge up to \u003cstrong\u003e50 ft\u003c\/strong\u003e. Hyper low-ambient performance supports heating operation down to\n      \u003cstrong\u003e-22°F\u003c\/strong\u003e (ambient), while cooling operation ranges from \u003cstrong\u003e5–122°F\u003c\/strong\u003e.\n    \u003c\/p\u003e\n  \u003c\/div\u003e\n\n  \u003cdiv class=\"hvx-desc-card\"\u003e\n    \u003ch2 class=\"hvx-section-title\"\u003eHighlights\u003c\/h2\u003e\n\n    \u003cdiv class=\"hvx-badges\" role=\"list\"\u003e\n      \u003cspan class=\"hvx-badge\" role=\"listitem\"\u003e19,000 BTU (rated)\u003c\/span\u003e\n      \u003cspan class=\"hvx-badge\" role=\"listitem\"\u003eHyper Multi-Zone\u003c\/span\u003e\n      \u003cspan class=\"hvx-badge\" role=\"listitem\"\u003eR410A\u003c\/span\u003e\n      \u003cspan class=\"hvx-badge\" role=\"listitem\"\u003eSEER2 22\u003c\/span\u003e\n      \u003cspan class=\"hvx-badge\" role=\"listitem\"\u003eEER2 12.5\u003c\/span\u003e\n      \u003cspan class=\"hvx-badge\" role=\"listitem\"\u003eHSPF2-4 9.8\u003c\/span\u003e\n      \u003cspan class=\"hvx-badge\" role=\"listitem\"\u003eHSPF2-5 7.7\u003c\/span\u003e\n      \u003cspan class=\"hvx-badge\" role=\"listitem\"\u003e-22°F Heating\u003c\/span\u003e\n      \u003cspan class=\"hvx-badge\" role=\"listitem\"\u003eMax Pipe 131 ft\u003c\/span\u003e\n      \u003cspan class=\"hvx-badge\" role=\"listitem\"\u003ePrecharge up to 50 ft\u003c\/span\u003e\n      \u003cspan class=\"hvx-badge\" role=\"listitem\"\u003eOutdoor Sound 61 dB(A)\u003c\/span\u003e\n    \u003c\/div\u003e\n\n    \u003cul style=\"margin:12px 0 0; padding-left:18px;\"\u003e\n      \u003cli\u003e\n\u003cstrong\u003eCold-climate capable:\u003c\/strong\u003e Heating ambient range down to \u003cstrong\u003e-22°F\u003c\/strong\u003e.\u003c\/li\u003e\n      \u003cli\u003e\n\u003cstrong\u003eEfficiency:\u003c\/strong\u003e Rated \u003cstrong\u003eSEER2 22\u003c\/strong\u003e and \u003cstrong\u003eEER2 12.5\u003c\/strong\u003e (system dependent).\u003c\/li\u003e\n      \u003cli\u003e\n\u003cstrong\u003eCapacity modulation:\u003c\/strong\u003e Cooling range \u003cstrong\u003e5,500–25,000 BTU\/h\u003c\/strong\u003e; heating range \u003cstrong\u003e8,100–29,600 BTU\/h\u003c\/strong\u003e.\u003c\/li\u003e\n      \u003cli\u003e\n\u003cstrong\u003eInstallation parameters:\u003c\/strong\u003e Max total piping \u003cstrong\u003e131 ft\u003c\/strong\u003e and height difference up to \u003cstrong\u003e49.21 ft\u003c\/strong\u003e.\u003c\/li\u003e\n      \u003cli\u003e\n\u003cstrong\u003eBranch connections:\u003c\/strong\u003e Listed as \u003cstrong\u003e2× 1\/4\"\u003c\/strong\u003e liquid and \u003cstrong\u003e2× 3\/8\"\u003c\/strong\u003e gas ports.\u003c\/li\u003e\n    \u003c\/ul\u003e\n\n    \u003cdiv class=\"hvx-kv\" role=\"list\" aria-label=\"At-a-glance\"\u003e\n      \u003cdiv role=\"listitem\"\u003e\n\u003cstrong\u003eModel\u003c\/strong\u003eCH-HPR19M-230VO\u003c\/div\u003e\n      \u003cdiv role=\"listitem\"\u003e\n\u003cstrong\u003eSystem Type\u003c\/strong\u003eMulti-Zone\u003c\/div\u003e\n      \u003cdiv role=\"listitem\"\u003e\n\u003cstrong\u003eConnections\u003c\/strong\u003e2× 1\/4\" liq \/ 2× 3\/8\" gas\u003c\/div\u003e\n      \u003cdiv role=\"listitem\"\u003e\n\u003cstrong\u003ePower\u003c\/strong\u003e208–230V, 1Ph\u003c\/div\u003e\n    \u003c\/div\u003e\n  \u003c\/div\u003e\n\n  \u003cdiv class=\"hvx-desc-card\"\u003e\n    \u003ch2 class=\"hvx-section-title\"\u003eWhat's Included\u003c\/h2\u003e\n    \u003cul style=\"padding-left:18px; margin:8px 0;\"\u003e\n      \u003cli\u003eOutdoor condenser unit: \u003cstrong\u003eCH-HPR19M-230VO\u003c\/strong\u003e\n\u003c\/li\u003e\n    \u003c\/ul\u003e\n  \u003c\/div\u003e\n\n  \u003cdiv class=\"hvx-desc-card\"\u003e\n    \u003ch2 class=\"hvx-section-title\"\u003eOutdoor Specs\u003c\/h2\u003e\n    \u003cdiv class=\"hvx-table-wrap\"\u003e\n      \u003ctable class=\"hvx-table\" aria-label=\"Outdoor unit specifications\"\u003e\n        \u003cthead\u003e\n          \u003ctr\u003e\n\u003cth\u003eSpec\u003c\/th\u003e\n\u003cth\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\n        \u003c\/thead\u003e\n        \u003ctbody\u003e\n          \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCH-HPR19M-230VO\u003c\/td\u003e\n\u003c\/tr\u003e\n          \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRefrigerant Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eR410A\u003c\/td\u003e\n\u003c\/tr\u003e\n          \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSystem Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMulti-zone unit\u003c\/td\u003e\n\u003c\/tr\u003e\n          \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBTU Rated\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e19,000\u003c\/td\u003e\n\u003c\/tr\u003e\n          \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCooling Capacity (Min\/Max)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e19,000 (5,500–25,000) BTU\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n          \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eHeating Capacity (Min\/Max)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e20,000 (8,100–29,600) BTU\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n          \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSEER2 \/ EER2\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e22 \/ 12.5\u003c\/td\u003e\n\u003c\/tr\u003e\n          \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eHSPF2-4 \/ HSPF2-5\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e9.8 \/ 7.7\u003c\/td\u003e\n\u003c\/tr\u003e\n          \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCOP\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3.4\u003c\/td\u003e\n\u003c\/tr\u003e\n          \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower Source\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e208–230V, 1Ph, 60Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n          \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eVoltage Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e187–253 V\u003c\/td\u003e\n\u003c\/tr\u003e\n          \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMinimum Circuit Ampacity (MCA)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e20 A\u003c\/td\u003e\n\u003c\/tr\u003e\n          \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMax Fuse\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e25 A\u003c\/td\u003e\n\u003c\/tr\u003e\n          \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMax Pipe Length\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e131 ft\u003c\/td\u003e\n\u003c\/tr\u003e\n          \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMax Height Difference (Indoor↔Outdoor)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e49.21 ft\u003c\/td\u003e\n\u003c\/tr\u003e\n          \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRefrigerant Piping (Liquid \/ Gas)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2× 1\/4\" (liq) \/ 2× 3\/8\" (gas)\u003c\/td\u003e\n\u003c\/tr\u003e\n          \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRefrigerant Precharge\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eUp to 50 ft\u003c\/td\u003e\n\u003c\/tr\u003e\n          \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOutdoor Noise\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e61 dB(A)\u003c\/td\u003e\n\u003c\/tr\u003e\n          \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOutdoor Air Flow\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2,129.41\u003c\/td\u003e\n\u003c\/tr\u003e\n          \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAmbient Range (Cooling)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e5–122 °F\u003c\/td\u003e\n\u003c\/tr\u003e\n          \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAmbient Range (Heating)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-22–75 °F\u003c\/td\u003e\n\u003c\/tr\u003e\n          \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAdditional Charge (3\/8\" liquid)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.32\u003c\/td\u003e\n\u003c\/tr\u003e\n          \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAdditional Charge (1\/4\" liquid)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.16\u003c\/td\u003e\n\u003c\/tr\u003e\n          \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eUnit Dimensions (W×H×D)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e37.24 × 16.14 × 31.89 in\u003c\/td\u003e\n\u003c\/tr\u003e\n          \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eUnit Net \/ Gross Weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e138.23 \/ 149.03 lb\u003c\/td\u003e\n\u003c\/tr\u003e\n          \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePacking Dimensions (W×D×H)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e42.91 × 19.69 × 34.84\u003c\/td\u003e\n\u003c\/tr\u003e\n          \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDehumidification\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3.57 pints\/day\u003c\/td\u003e\n\u003c\/tr\u003e\n        \u003c\/tbody\u003e\n      \u003c\/table\u003e\n    \u003c\/div\u003e\n  \u003c\/div\u003e\n\n  \u003cdiv class=\"hvx-desc-card\"\u003e\n    \u003ch2 class=\"hvx-section-title\"\u003eVideos\u003c\/h2\u003e\n    \u003cdiv style=\"margin:8px 0 0;\"\u003e\n      \u003cdiv style=\"font-weight:800; margin:10px 0 6px;\"\u003eMini-Splits\u003c\/div\u003e\n      \u003cul style=\"padding-left:18px; margin:0;\"\u003e\n        \u003cli\u003e\u003ca class=\"hvx-link\" href=\"https:\/\/www.youtube.com\/watch?v=n00qcO3iIR0\" rel=\"noopener\" target=\"_blank\"\u003eCan You Use a Mini Split in EXTREME COLD? Heat Pump vs. Propane Cost Comparison with Thermal Camera\u003c\/a\u003e\u003c\/li\u003e\n        \u003cli\u003e\u003ca class=\"hvx-link\" href=\"https:\/\/www.youtube.com\/watch?v=5QgZqyFp334\" rel=\"noopener\" target=\"_blank\"\u003eWhere To Mount a Mini Split Indoor Wall Hung Unit\u003c\/a\u003e\u003c\/li\u003e\n        \u003cli\u003e\u003ca class=\"hvx-link\" href=\"https:\/\/www.youtube.com\/watch?v=hxYrOv5bV9Y\" rel=\"noopener\" target=\"_blank\"\u003eHow To Wall Mount a Mini Split Outdoor Condenser Unit\u003c\/a\u003e\u003c\/li\u003e\n        \u003cli\u003e\u003ca class=\"hvx-link\" href=\"https:\/\/www.youtube.com\/watch?v=3DHyShrGUXw\" rel=\"noopener\" target=\"_blank\"\u003eAre Mini Split Air Conditioners Worth It? - Top 5 Pros \u0026amp; Cons\u003c\/a\u003e\u003c\/li\u003e\n        \u003cli\u003e\u003ca class=\"hvx-link\" href=\"https:\/\/www.youtube.com\/watch?v=USU0xujHHL8\" rel=\"noopener\" target=\"_blank\"\u003eDoes a Wall Mounted MINISPLIT Need a CONDENSATE TRAP? Ductless vs Ducted Air Handlers!\u003c\/a\u003e\u003c\/li\u003e\n        \u003cli\u003e\u003ca class=\"hvx-link\" href=\"https:\/\/www.youtube.com\/watch?v=ATk1fx_N_qc\" rel=\"noopener\" target=\"_blank\"\u003eMINI SPLIT Parts Explained! Understand What They Do!\u003c\/a\u003e\u003c\/li\u003e\n        \u003cli\u003e\u003ca class=\"hvx-link\" href=\"https:\/\/www.youtube.com\/watch?v=-GHFRcvQwNA\" rel=\"noopener\" target=\"_blank\"\u003eMini Split Failure from Electrical Surges, High and Low Voltage! HOW TO SOLVE IT!\u003c\/a\u003e\u003c\/li\u003e\n        \u003cli\u003e\u003ca class=\"hvx-link\" href=\"https:\/\/www.youtube.com\/watch?v=ZNRlS2xOcVc\" rel=\"noopener\" target=\"_blank\"\u003eFull Installation of an Inverter Minisplit Heat Pump with Indoor Ceiling Cassette\u003c\/a\u003e\u003c\/li\u003e\n        \u003cli\u003e\u003ca class=\"hvx-link\" href=\"https:\/\/www.youtube.com\/watch?v=BxMwbC_2ow8\" rel=\"noopener\" target=\"_blank\"\u003eChecking the Refrigerant Charge on a Running R-410A Inverter MINI SPLIT Unit\u003c\/a\u003e\u003c\/li\u003e\n        \u003cli\u003e\u003ca class=\"hvx-link\" href=\"https:\/\/www.youtube.com\/watch?v=qCWu8HCNl3Q\" rel=\"noopener\" target=\"_blank\"\u003eMini Split Indoor Unit Types Explained! 5 Types- Applications, Connection Points, Mounting!\u003c\/a\u003e\u003c\/li\u003e\n      \u003c\/ul\u003e\n    \u003c\/div\u003e\n  \u003c\/div\u003e\n\n  \u003cdiv class=\"hvx-desc-card\"\u003e\n    \u003ch2 class=\"hvx-section-title\"\u003eDocuments \u0026amp; Downloads\u003c\/h2\u003e\n    \u003cul style=\"padding-left:18px; margin:8px 0;\"\u003e\n      \u003cli\u003e\u003ca class=\"hvx-link\" href=\"https:\/\/media.cooperandhunter.us\/3170\/CH-HPR19M-230VO-%28Ducted%29.pdf\" rel=\"noopener\" target=\"_blank\"\u003eSubmittal — CH-HPR19M-230VO (Ducted) (PDF)\u003c\/a\u003e\u003c\/li\u003e\n      \u003cli\u003e\u003ca class=\"hvx-link\" href=\"https:\/\/media.cooperandhunter.us\/3171\/CH-HPR19M-230VO-%28Non-ducted%29.pdf\" rel=\"noopener\" target=\"_blank\"\u003eSubmittal — CH-HPR19M-230VO (Non-Ducted) (PDF)\u003c\/a\u003e\u003c\/li\u003e\n      \u003cli\u003e\u003ca class=\"hvx-link\" href=\"https:\/\/media.cooperandhunter.us\/4433\/Installation-manual.pdf\" rel=\"noopener\" target=\"_blank\"\u003eInstallation Manual — Multi-Zone Outdoor (PDF)\u003c\/a\u003e\u003c\/li\u003e\n      \u003cli\u003e\u003ca class=\"hvx-link\" href=\"https:\/\/media.cooperandhunter.us\/3198\/MultiZone-Combination-HYPER.pdf\" rel=\"noopener\" target=\"_blank\"\u003eMulti-Zone Combination — HYPER (PDF)\u003c\/a\u003e\u003c\/li\u003e\n    \u003c\/ul\u003e\n  \u003c\/div\u003e\n\n  \u003cdiv class=\"hvx-desc-card\"\u003e\n    \u003ch2 class=\"hvx-section-title\"\u003eCertifications\u003c\/h2\u003e\n    \u003cul style=\"padding-left:18px; margin:8px 0;\"\u003e\n      \u003cli\u003eAHRI Ducted — \u003cstrong\u003e210799629\u003c\/strong\u003e (\u003ca class=\"hvx-link\" href=\"https:\/\/www.ahridirectory.org\/NewSearch?programId=41\u0026amp;searchTypeId=3\u0026amp;productTypeId=4\" rel=\"noopener\" target=\"_blank\"\u003eAHRI Directory\u003c\/a\u003e)\u003c\/li\u003e\n      \u003cli\u003eAHRI Non-Ducted — \u003cstrong\u003e210799628\u003c\/strong\u003e (\u003ca class=\"hvx-link\" href=\"https:\/\/www.ahridirectory.org\/NewSearch?programId=41\u0026amp;searchTypeId=3\u0026amp;productTypeId=4\" rel=\"noopener\" target=\"_blank\"\u003eAHRI Directory\u003c\/a\u003e)\u003c\/li\u003e\n      \u003cli\u003eAHRI Mixed — \u003cstrong\u003e210799630\u003c\/strong\u003e (\u003ca class=\"hvx-link\" href=\"https:\/\/www.ahridirectory.org\/NewSearch?programId=41\u0026amp;searchTypeId=3\u0026amp;productTypeId=4\" rel=\"noopener\" target=\"_blank\"\u003eAHRI Directory\u003c\/a\u003e)\u003c\/li\u003e\n    \u003c\/ul\u003e\n  \u003c\/div\u003e\n\n  \u003cdiv class=\"hvx-desc-card\"\u003e\n    \u003ch2 class=\"hvx-section-title\"\u003eImportant\u003c\/h2\u003e\n    \u003cp style=\"margin:0; font-size:14px;\"\u003e\n      Install with a licensed HVAC professional. This is a \u003cstrong\u003emulti-zone outdoor condenser\u003c\/strong\u003e intended to be matched with compatible indoor units.\n      Confirm match-ups, total connected indoor capacity, and piping design before ordering. Observe maximum total piping (\u003cstrong\u003e131 ft\u003c\/strong\u003e),\n      height limits (\u003cstrong\u003e49.21 ft\u003c\/strong\u003e), and required electrical protection (\u003cstrong\u003eMCA 20A\u003c\/strong\u003e, \u003cstrong\u003emax fuse 25A\u003c\/strong\u003e).\n      Refrigerant is \u003cstrong\u003eR410A\u003c\/strong\u003e with factory precharge up to \u003cstrong\u003e50 ft\u003c\/strong\u003e; additional charge may be required beyond that length.\n    \u003c\/p\u003e\n  \u003c\/div\u003e\n\n  \u003cdiv class=\"hvx-desc-card\"\u003e\n    \u003ch2 class=\"hvx-section-title\"\u003eFAQs\u003c\/h2\u003e\n\n    \u003cdetails class=\"hvx-faq\" open\u003e\n      \u003csummary\u003eIs this a single-zone or multi-zone outdoor unit?\u003c\/summary\u003e\n      \u003cdiv style=\"margin-top:8px;\"\u003eThis model is a \u003cstrong\u003emulti-zone\u003c\/strong\u003e outdoor condenser.\u003c\/div\u003e\n    \u003c\/details\u003e\n\n    \u003cdetails class=\"hvx-faq\" open\u003e\n      \u003csummary\u003eHow many indoor units can it connect to?\u003c\/summary\u003e\n      \u003cdiv style=\"margin-top:8px;\"\u003eThe piping spec lists \u003cstrong\u003e2\u003c\/strong\u003e liquid connections and \u003cstrong\u003e2\u003c\/strong\u003e gas connections, indicating support for up to \u003cstrong\u003etwo zones\u003c\/strong\u003e when matched correctly.\u003c\/div\u003e\n    \u003c\/details\u003e\n\n    \u003cdetails class=\"hvx-faq\" open\u003e\n      \u003csummary\u003eHow cold can it heat in?\u003c\/summary\u003e\n      \u003cdiv style=\"margin-top:8px;\"\u003eHeating ambient range is \u003cstrong\u003e-22–75°F\u003c\/strong\u003e.\u003c\/div\u003e\n    \u003c\/details\u003e\n\n    \u003cdetails class=\"hvx-faq\" open\u003e\n      \u003csummary\u003eHow much piping is supported?\u003c\/summary\u003e\n      \u003cdiv style=\"margin-top:8px;\"\u003eMaximum total piping length is \u003cstrong\u003e131 ft\u003c\/strong\u003e, with a maximum indoor\/outdoor height difference up to \u003cstrong\u003e49.21 ft\u003c\/strong\u003e.\u003c\/div\u003e\n    \u003c\/details\u003e\n\n    \u003cdetails class=\"hvx-faq\" open\u003e\n      \u003csummary\u003eDoes it come precharged with refrigerant?\u003c\/summary\u003e\n      \u003cdiv style=\"margin-top:8px;\"\u003eYes. The factory refrigerant precharge covers up to \u003cstrong\u003e50 ft\u003c\/strong\u003e of piping. Additional refrigerant may be required beyond that length.\u003c\/div\u003e\n    \u003c\/details\u003e\n  \u003c\/div\u003e\n\u003c\/div\u003e\n","brand":"Cooper\u0026Hunter","offers":[{"title":"Default Title","offer_id":43087858827307,"sku":"CH-HPR19M-230VO","price":1692.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0625\/5647\/1339\/files\/HYPER-MULTI-19-24_1.jpg?v=1771433367"},{"product_id":"cooper-hunter-hyper-multi-zone-r410a-outdoor-condenser-55-000-btu-4-5-ton","title":"Cooper\u0026Hunter Hyper Multi-Zone R410A Outdoor Condenser 55,000 BTU (4.5 Ton)","description":"\u003cstyle\u003e\n  :root{\n    --hvx-golden:#FAA819;\n    --hvx-slate:#262626;\n    --hvx-ivory:#F4F1E6;\n    --hvx-border:#e2e0d5;\n    --hvx-card-bg:#ffffff;\n  }\n\n  .hvx-desc{\n    font-family:\"Articulat CF\",system-ui,-apple-system,BlinkMacSystemFont,\"Segoe UI\",sans-serif;\n    color:var(--hvx-slate);\n    line-height:1.6;\n    background:var(--hvx-ivory);\n    padding:18px 18px 20px;\n    border-radius:16px;\n  }\n\n  .hvx-desc-header{\n    border-radius:14px;\n    padding:14px 16px;\n    background:linear-gradient(120deg,var(--hvx-golden),var(--hvx-slate));\n    color:#fff;\n    margin:0 0 16px;\n    box-shadow:0 10px 24px rgba(0,0,0,.22);\n    display:flex;\n    align-items:flex-start;\n    gap:12px;\n    flex-wrap:wrap;\n  }\n\n  .hvx-header-text{display:flex;flex-direction:column;gap:6px;min-width:260px}\n  .hvx-eyebrow{\n    font-size:11px;\n    letter-spacing:.14em;\n    text-transform:uppercase;\n    opacity:.9;\n  }\n  .hvx-title{\n    margin:0;\n    font-family:\"Anton\",\"Impact\",system-ui,-apple-system,BlinkMacSystemFont,\"Segoe UI\",sans-serif;\n    font-size:22px;\n    line-height:1.15;\n  }\n  .hvx-subtitle{\n    margin:0;\n    font-size:14px;\n    opacity:.95;\n  }\n\n  .hvx-desc-card{\n    border:1px solid var(--hvx-border);\n    border-radius:14px;\n    background:var(--hvx-card-bg);\n    padding:16px 18px 18px;\n    box-shadow:0 4px 12px rgba(0,0,0,.06);\n    margin:14px 0;\n  }\n\n  .hvx-section-title{\n    margin:0 0 10px;\n    font-family:\"Anton\",\"Impact\",system-ui,-apple-system,BlinkMacSystemFont,\"Segoe UI\",sans-serif;\n    font-size:17px;\n    letter-spacing:.08em;\n    text-transform:uppercase;\n    color:var(--hvx-slate);\n    display:inline-flex;\n    align-items:center;\n    gap:8px;\n  }\n  .hvx-section-title::after{\n    content:\"\";\n    flex:1;\n    height:2px;\n    border-radius:999px;\n    background:linear-gradient(90deg,var(--hvx-golden),transparent);\n    opacity:.9;\n  }\n\n  .hvx-cta{display:flex;flex-wrap:wrap;gap:10px;margin:10px 0 0}\n  .hvx-cta a{\n    display:inline-flex;\n    align-items:center;\n    gap:8px;\n    padding:10px 14px;\n    border-radius:12px;\n    border:1px solid var(--hvx-border);\n    background:#fff;\n    text-decoration:none;\n    color:var(--hvx-slate);\n    font-size:14px;\n    font-weight:700;\n  }\n  .hvx-cta a.primary{\n    background:var(--hvx-slate);\n    color:#fff;\n    border-color:transparent;\n  }\n\n  .hvx-badges{display:flex;flex-wrap:wrap;gap:8px;margin:10px 0 0}\n  .hvx-badge{\n    font-size:12px;\n    border:1px solid var(--hvx-border);\n    border-radius:999px;\n    padding:6px 10px;\n    background:#fff;\n    white-space:nowrap;\n  }\n\n  .hvx-kv{\n    display:grid;\n    grid-template-columns:repeat(4,minmax(160px,1fr));\n    gap:10px;\n    margin-top:10px;\n  }\n  .hvx-kv \u003e div{\n    border:1px solid var(--hvx-border);\n    background:#fff;\n    border-radius:12px;\n    padding:10px 12px;\n    text-align:center;\n  }\n  .hvx-kv strong{display:block}\n\n  .hvx-table{\n    width:100%;\n    border-collapse:collapse;\n    min-width:520px;\n    background:#fff;\n    border:1px solid var(--hvx-border);\n    border-radius:12px;\n    overflow:hidden;\n  }\n  .hvx-table th,.hvx-table td{\n    border-bottom:1px solid var(--hvx-border);\n    padding:10px 12px;\n    vertical-align:top;\n    font-size:14px;\n  }\n  .hvx-table th{ text-align:left; font-weight:800; background:#fff; }\n  .hvx-table tr:nth-child(even) td{ background:#fbfaf6; }\n  .hvx-table tr:last-child td{ border-bottom:none; }\n  .hvx-table-wrap{ overflow:auto; border-radius:12px; }\n\n  .hvx-link{color:var(--hvx-slate); text-decoration:underline; text-underline-offset:2px}\n  .hvx-link:hover{opacity:.85}\n\n  details.hvx-faq{\n    border:1px solid var(--hvx-border);\n    background:#fff;\n    border-radius:12px;\n    padding:10px 12px;\n    margin:8px 0;\n  }\n  details.hvx-faq summary{cursor:pointer;font-weight:800;}\n\n  @media(max-width:980px){\n    .hvx-kv{grid-template-columns:repeat(2,minmax(160px,1fr))}\n  }\n  @media(max-width:768px){\n    .hvx-desc{padding:14px 12px 16px;border-radius:12px}\n    .hvx-desc-header{padding:12px;border-radius:12px}\n    .hvx-title{font-size:19px}\n    .hvx-desc-card{padding:14px;margin:10px 0}\n  }\n\u003c\/style\u003e\n\u003cdiv class=\"hvx-desc\"\u003e\n\u003cdiv class=\"hvx-desc-header\"\u003e\n\u003cdiv class=\"hvx-header-text\"\u003e\n\u003cdiv class=\"hvx-eyebrow\"\u003eCooper\u0026amp;Hunter Hyper Multi-Zone Outdoor Condenser • R410A • 230V\u003c\/div\u003e\n\u003ch1 class=\"hvx-title\"\u003eCooper\u0026amp;Hunter Hyper Multi-Zone Outdoor Condenser — 55,000 BTU (4.5 Ton) • CH-HPR55M-230VO\u003c\/h1\u003e\n\u003cp class=\"hvx-subtitle\"\u003eHyper Heat multi-zone condenser for dependable comfort down to -22°F (ambient), supporting up to 5 zones (system design dependent).\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv aria-label=\"Contact options\" class=\"hvx-cta\"\u003e\n\u003ca title=\"Contact Us\" rel=\"noopener\" href=\"https:\/\/hvacsupplies.com\/pages\/contact\" class=\"primary\" target=\"_blank\"\u003eCLICK HERE TO CONTACT US FOR CUSTOM QUOTES AND QUESTIONS\u003c\/a\u003e \u003ca title=\"Call Us Now!\" href=\"tel:+18005438933\"\u003eCLICK TO CALL US 1-800-543-8933 FOR ANY QUESTIONS\u003c\/a\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"hvx-desc-card\"\u003e\n\u003ch2 class=\"hvx-section-title\"\u003eOverview\u003c\/h2\u003e\n\u003cp style=\"margin: 0;\"\u003eThe \u003cstrong\u003eCH-HPR55M-230VO\u003c\/strong\u003e is a \u003cstrong\u003eHyper Heat\u003c\/strong\u003e \u003cstrong\u003emulti-zone\u003c\/strong\u003e outdoor condenser rated at \u003cstrong\u003e55,000 BTU\u003c\/strong\u003e (4.5 ton) for \u003cstrong\u003eR410A\u003c\/strong\u003e systems on \u003cstrong\u003e208–230V\u003c\/strong\u003e power. It is built to deliver dependable heating and cooling in demanding conditions, with heating operation supported in ambient temperatures as low as \u003cstrong\u003e-22°F\u003c\/strong\u003e and cooling operation from \u003cstrong\u003e5–122°F\u003c\/strong\u003e. The unit supports up to \u003cstrong\u003e262 ft\u003c\/strong\u003e of total piping, factory precharge up to \u003cstrong\u003e125 ft\u003c\/strong\u003e, and is designed to accommodate up to \u003cstrong\u003e5 independent zones\u003c\/strong\u003e with a mix-and-match of compatible indoor unit types.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"hvx-desc-card\"\u003e\n\u003ch2 class=\"hvx-section-title\"\u003eHighlights\u003c\/h2\u003e\n\u003cdiv role=\"list\" class=\"hvx-badges\"\u003e\n\u003cspan role=\"listitem\" class=\"hvx-badge\"\u003e55,000 BTU (rated)\u003c\/span\u003e \u003cspan role=\"listitem\" class=\"hvx-badge\"\u003eUp to 5 Zones\u003c\/span\u003e \u003cspan role=\"listitem\" class=\"hvx-badge\"\u003eHyper Heat\u003c\/span\u003e \u003cspan role=\"listitem\" class=\"hvx-badge\"\u003eR410A\u003c\/span\u003e \u003cspan role=\"listitem\" class=\"hvx-badge\"\u003eSEER2 22\u003c\/span\u003e \u003cspan role=\"listitem\" class=\"hvx-badge\"\u003eEER2 10.5\u003c\/span\u003e \u003cspan role=\"listitem\" class=\"hvx-badge\"\u003eHSPF2-4 9.3\u003c\/span\u003e \u003cspan role=\"listitem\" class=\"hvx-badge\"\u003eHSPF2-5 7.3\u003c\/span\u003e \u003cspan role=\"listitem\" class=\"hvx-badge\"\u003e-22°F Heating\u003c\/span\u003e \u003cspan role=\"listitem\" class=\"hvx-badge\"\u003eMax Pipe 262 ft\u003c\/span\u003e \u003cspan role=\"listitem\" class=\"hvx-badge\"\u003ePrecharge up to 125 ft\u003c\/span\u003e \u003cspan role=\"listitem\" class=\"hvx-badge\"\u003eOutdoor Sound 63 dB(A)\u003c\/span\u003e\n\u003c\/div\u003e\n\u003cul style=\"margin: 12px 0 0; padding-left: 18px;\"\u003e\n\u003cli\u003e\n\u003cstrong\u003eCold-climate performance:\u003c\/strong\u003e Heating ambient range down to \u003cstrong\u003e-22°F\u003c\/strong\u003e.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMulti-zone flexibility:\u003c\/strong\u003e Designed to support up to \u003cstrong\u003e5\u003c\/strong\u003e independent zones (system design dependent).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCapacity modulation:\u003c\/strong\u003e Cooling range \u003cstrong\u003e19,000–58,000 BTU\/h\u003c\/strong\u003e; heating range \u003cstrong\u003e12,500–57,500 BTU\/h\u003c\/strong\u003e.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInstallation parameters:\u003c\/strong\u003e Max total piping \u003cstrong\u003e262 ft\u003c\/strong\u003e and height difference up to \u003cstrong\u003e49.21 ft\u003c\/strong\u003e.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBranch connections:\u003c\/strong\u003e Listed as \u003cstrong\u003e5× 1\/4\"\u003c\/strong\u003e liquid and \u003cstrong\u003e3× 3\/8\" + 2× 1\/2\"\u003c\/strong\u003e gas ports.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cdiv aria-label=\"At-a-glance\" role=\"list\" class=\"hvx-kv\"\u003e\n\u003cdiv role=\"listitem\"\u003e\n\u003cstrong\u003eModel\u003c\/strong\u003eCH-HPR55M-230VO\u003c\/div\u003e\n\u003cdiv role=\"listitem\"\u003e\n\u003cstrong\u003eSystem Type\u003c\/strong\u003eMulti-Zone\u003c\/div\u003e\n\u003cdiv role=\"listitem\"\u003e\n\u003cstrong\u003eMax Pipe\u003c\/strong\u003e262 ft\u003c\/div\u003e\n\u003cdiv role=\"listitem\"\u003e\n\u003cstrong\u003ePower\u003c\/strong\u003e208–230V, 1Ph\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"hvx-desc-card\"\u003e\n\u003ch2 class=\"hvx-section-title\"\u003eWhat's Included\u003c\/h2\u003e\n\u003cul style=\"padding-left: 18px; margin: 8px 0;\"\u003e\n\u003cli\u003eOutdoor condenser unit: \u003cstrong\u003eCH-HPR55M-230VO\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"hvx-desc-card\"\u003e\n\u003ch2 class=\"hvx-section-title\"\u003eOutdoor Specs\u003c\/h2\u003e\n\u003cdiv class=\"hvx-table-wrap\"\u003e\n\u003ctable aria-label=\"Outdoor unit specifications\" class=\"hvx-table\"\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eSpec\u003c\/th\u003e\n\u003cth\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCH-HPR55M-230VO\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRefrigerant Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eR410A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSystem Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMulti-zone unit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBTU Rated\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e55,000\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCooling Capacity (Min\/Max)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e55,000 (19,000–58,000) BTU\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eHeating Capacity (Min\/Max)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e55,000 (12,500–57,500) BTU\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSEER2 \/ EER2\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e22 \/ 10.5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eHSPF2-4 \/ HSPF2-5\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e9.3 \/ 7.3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCOP\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3.5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower Source\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e208–230V, 1Ph, 60Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eVoltage Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e187–253 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMinimum Circuit Ampacity (MCA)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e40 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMax Fuse\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e60 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMax Pipe Length\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e262 ft\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMax Height Difference (Indoor↔Outdoor)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e49.21 ft\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRefrigerant Piping (Liquid \/ Gas)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e5× 1\/4\" (liq) \/ 3× 3\/8\" + 2× 1\/2\" (gas)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRefrigerant Precharge\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eUp to 125 ft\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOutdoor Noise\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e63 dB(A)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOutdoor Air Flow\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4,500\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAmbient Range (Cooling)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e5–122 °F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAmbient Range (Heating)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-22–75 °F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAdditional Charge (3\/8\" liquid)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.32\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAdditional Charge (1\/4\" liquid)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.16\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eUnit Dimensions (W×H×D)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e37.48 × 16.34 × 52.48 in\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eUnit Net \/ Gross Weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e233.03 \/ 265.87 lb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePacking Dimensions (W×D×H)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e43.11 × 19.49 × 58.27\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDehumidification\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e11.37 pints\/day\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"hvx-desc-card\"\u003e\n\u003ch2 class=\"hvx-section-title\"\u003eVideos\u003c\/h2\u003e\n\u003cdiv style=\"margin: 8px 0 0;\"\u003e\n\u003cdiv style=\"font-weight: 800; margin: 10px 0 6px;\"\u003eMini-split installation videos\u003c\/div\u003e\n\u003cul style=\"padding-left: 18px; margin: 0;\"\u003e\n\u003cli\u003e\u003ca rel=\"noopener\" href=\"https:\/\/youtu.be\/hDEhQ94r2rQ\" class=\"hvx-link\" target=\"_blank\"\u003eHow to Install Mini Split Cooper\u0026amp;Hunter\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca rel=\"noopener\" href=\"https:\/\/youtu.be\/JQkth-AM5CE\" class=\"hvx-link\" target=\"_blank\"\u003eFull Installation of Mini Split Ductless Unit, Step by Step!\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"margin: 10px 0 0;\"\u003e\n\u003cdiv style=\"font-weight: 800; margin: 10px 0 6px;\"\u003eHow To \u0026amp; Instructional Videos\u003c\/div\u003e\n\u003cul style=\"padding-left: 18px; margin: 0;\"\u003e\n\u003cli\u003e\u003ca rel=\"noopener\" href=\"https:\/\/youtu.be\/Z7jhBvW4uw8\" class=\"hvx-link\" target=\"_blank\"\u003eCooper\u0026amp;Hunter New Remote Control (2022)\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"margin: 10px 0 0;\"\u003e\n\u003cdiv style=\"font-weight: 800; margin: 10px 0 6px;\"\u003eProducts overview\u003c\/div\u003e\n\u003cul style=\"padding-left: 18px; margin: 0;\"\u003e\n\u003cli\u003e\u003ca rel=\"noopener\" href=\"https:\/\/youtu.be\/0kUh03W9qS8\" class=\"hvx-link\" target=\"_blank\"\u003eCooper\u0026amp;Hunter: Multi Zone AC for the Home\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca rel=\"noopener\" href=\"https:\/\/youtu.be\/k6PXB12pGe0\" class=\"hvx-link\" target=\"_blank\"\u003eCooper\u0026amp;Hunter HYPER HEAT Mini Split Series\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca rel=\"noopener\" href=\"https:\/\/youtu.be\/2u0pa2jThCM\" class=\"hvx-link\" target=\"_blank\"\u003eHVAC Installation Kit: 99.9% Copper Line Sets (Cooper\u0026amp;Hunter)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca rel=\"noopener\" href=\"https:\/\/youtu.be\/qCWu8HCNl3Q\" class=\"hvx-link\" target=\"_blank\"\u003eMini Split Indoor Unit Types Explained\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"hvx-desc-card\"\u003e\n\u003ch2 class=\"hvx-section-title\"\u003eDocuments \u0026amp; Downloads\u003c\/h2\u003e\n\u003cul style=\"padding-left: 18px; margin: 8px 0;\"\u003e\n\u003cli\u003e\u003ca rel=\"noopener\" href=\"https:\/\/media.cooperandhunter.us\/3178\/CH-HPR55M-230VO-%28Ducted%29.pdf\" class=\"hvx-link\" target=\"_blank\"\u003eSubmittal — CH-HPR55M-230VO (Ducted) (PDF)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca rel=\"noopener\" href=\"https:\/\/media.cooperandhunter.us\/3179\/CH-HPR55M-230VO-%28Non-ducted%29.pdf\" class=\"hvx-link\" target=\"_blank\"\u003eSubmittal — CH-HPR55M-230VO (Non-Ducted) (PDF)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca rel=\"noopener\" href=\"https:\/\/media.cooperandhunter.us\/4433\/Installation-manual.pdf\" class=\"hvx-link\" target=\"_blank\"\u003eInstallation Manual — Multi-Zone Outdoor (PDF)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca rel=\"noopener\" href=\"https:\/\/media.cooperandhunter.us\/3198\/MultiZone-Combination-HYPER.pdf\" class=\"hvx-link\" target=\"_blank\"\u003eMulti-Zone Combination — HYPER (PDF)\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"hvx-desc-card\"\u003e\n\u003ch2 class=\"hvx-section-title\"\u003eCertifications\u003c\/h2\u003e\n\u003cul style=\"padding-left: 18px; margin: 8px 0;\"\u003e\n\u003cli\u003eAHRI Ducted — \u003cstrong\u003e210799645\u003c\/strong\u003e (\u003ca rel=\"noopener\" href=\"https:\/\/www.ahridirectory.org\/NewSearch?programId=41\u0026amp;searchTypeId=3\u0026amp;productTypeId=4\" class=\"hvx-link\" target=\"_blank\"\u003eAHRI Directory\u003c\/a\u003e)\u003c\/li\u003e\n\u003cli\u003eAHRI Non-Ducted — \u003cstrong\u003e210799644\u003c\/strong\u003e (\u003ca rel=\"noopener\" href=\"https:\/\/www.ahridirectory.org\/NewSearch?programId=41\u0026amp;searchTypeId=3\u0026amp;productTypeId=4\" class=\"hvx-link\" target=\"_blank\"\u003eAHRI Directory\u003c\/a\u003e)\u003c\/li\u003e\n\u003cli\u003eAHRI Mixed — \u003cstrong\u003e210799646\u003c\/strong\u003e (\u003ca rel=\"noopener\" href=\"https:\/\/www.ahridirectory.org\/NewSearch?programId=41\u0026amp;searchTypeId=3\u0026amp;productTypeId=4\" class=\"hvx-link\" target=\"_blank\"\u003eAHRI Directory\u003c\/a\u003e)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"hvx-desc-card\"\u003e\n\u003ch2 class=\"hvx-section-title\"\u003eImportant\u003c\/h2\u003e\n\u003cp style=\"margin: 0; font-size: 14px;\"\u003eInstall with a licensed HVAC professional. This is a \u003cstrong\u003emulti-zone Hyper Heat outdoor condenser\u003c\/strong\u003e intended to be matched with compatible indoor units. Confirm match-ups, total connected indoor capacity, and piping design before ordering. Observe maximum total piping (\u003cstrong\u003e262 ft\u003c\/strong\u003e), height limits (\u003cstrong\u003e49.21 ft\u003c\/strong\u003e), and required electrical protection (\u003cstrong\u003eMCA 40A\u003c\/strong\u003e, \u003cstrong\u003emax fuse 60A\u003c\/strong\u003e). Refrigerant is \u003cstrong\u003eR410A\u003c\/strong\u003e with factory precharge up to \u003cstrong\u003e125 ft\u003c\/strong\u003e; additional charge may be required beyond that length.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"hvx-desc-card\"\u003e\n\u003ch2 class=\"hvx-section-title\"\u003eFAQs\u003c\/h2\u003e\n\u003cdetails open=\"\" class=\"hvx-faq\"\u003e\n\u003csummary\u003eIs this a single-zone or multi-zone outdoor unit?\u003c\/summary\u003e\n\u003cdiv style=\"margin-top: 8px;\"\u003eThis model is a \u003cstrong\u003emulti-zone\u003c\/strong\u003e outdoor condenser.\u003c\/div\u003e\n\u003c\/details\u003e\n\u003cdetails open=\"\" class=\"hvx-faq\"\u003e\n\u003csummary\u003eHow many zones can it support?\u003c\/summary\u003e\n\u003cdiv style=\"margin-top: 8px;\"\u003eIt is designed to accommodate up to \u003cstrong\u003e5 independent zones\u003c\/strong\u003e when matched and configured correctly.\u003c\/div\u003e\n\u003c\/details\u003e\n\u003cdetails open=\"\" class=\"hvx-faq\"\u003e\n\u003csummary\u003eHow cold can it heat in?\u003c\/summary\u003e\n\u003cdiv style=\"margin-top: 8px;\"\u003eHeating ambient range is \u003cstrong\u003e-22–75°F\u003c\/strong\u003e.\u003c\/div\u003e\n\u003c\/details\u003e\n\u003cdetails open=\"\" class=\"hvx-faq\"\u003e\n\u003csummary\u003eHow much piping is supported?\u003c\/summary\u003e\n\u003cdiv style=\"margin-top: 8px;\"\u003eMaximum total piping length is \u003cstrong\u003e262 ft\u003c\/strong\u003e, with a maximum indoor\/outdoor height difference up to \u003cstrong\u003e49.21 ft\u003c\/strong\u003e.\u003c\/div\u003e\n\u003c\/details\u003e\n\u003cdetails open=\"\" class=\"hvx-faq\"\u003e\n\u003csummary\u003eDoes it come precharged with refrigerant?\u003c\/summary\u003e\n\u003cdiv style=\"margin-top: 8px;\"\u003eYes. The factory refrigerant precharge covers up to \u003cstrong\u003e125 ft\u003c\/strong\u003e of piping. Additional refrigerant may be required beyond that length.\u003c\/div\u003e\n\u003c\/details\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e","brand":"Cooper\u0026Hunter","offers":[{"title":"Default Title","offer_id":43087873441835,"sku":"CH-HPR55M-230VO","price":4769.0,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0625\/5647\/1339\/files\/HYPER-MULTI-36K-55K.jpg?v=1771433385"}],"url":"https:\/\/hvacsupplies.com\/collections\/ductless-multi-zone-hyper-heat-outdoor-units-cooper-and-hunter.oembed","provider":"HVACSupplies.com","version":"1.0","type":"link"}