{"title":"Cooper\u0026Hunter","description":"","products":[{"product_id":"cooper-hunter-6-000-btu-olivia-hyper-single-zone-wall-mount-minisplit-heat-pump-system-r454b-230v","title":"Cooper\u0026Hunter 6,000 BTU Olivia Hyper Single Zone Wall Mount Minisplit Heat Pump System R454B 230V","description":"\u003cstyle\u003e\n  :root{\n    --hvx-golden:#FAA819;\n    --hvx-slate:#262626;\n    --hvx-ivory:#F4F1E6;\n    --hvx-border:#e2e0d5;\n    --hvx-card-bg:#ffffff;\n  }\n\n  .hvx-desc{\n    font-family:\"Articulat CF\",system-ui,-apple-system,BlinkMacSystemFont,\"Segoe UI\",sans-serif;\n    color:var(--hvx-slate);\n    line-height:1.6;\n    background:var(--hvx-ivory);\n    padding:18px 18px 20px;\n    border-radius:16px;\n  }\n\n  .hvx-desc-header{\n    border-radius:14px;\n    padding:14px 16px;\n    background:linear-gradient(120deg,var(--hvx-golden),var(--hvx-slate));\n    color:#fff;\n    margin:0 0 16px;\n    box-shadow:0 10px 24px rgba(0,0,0,.22);\n    display:flex;\n    align-items:flex-start;\n    gap:12px;\n    flex-wrap:wrap;\n  }\n\n  .hvx-header-text{display:flex;flex-direction:column;gap:6px;min-width:260px}\n  .hvx-eyebrow{\n    font-size:11px;\n    letter-spacing:.14em;\n    text-transform:uppercase;\n    opacity:.9;\n  }\n  .hvx-title{\n    margin:0;\n    font-family:\"Anton\",\"Impact\",system-ui,-apple-system,BlinkMacSystemFont,\"Segoe UI\",sans-serif;\n    font-size:22px;\n    line-height:1.15;\n  }\n  .hvx-subtitle{margin:0;font-size:14px;opacity:.95}\n\n  .hvx-desc-card{\n    border:1px solid var(--hvx-border);\n    border-radius:14px;\n    background:var(--hvx-card-bg);\n    padding:16px 18px 18px;\n    box-shadow:0 4px 12px rgba(0,0,0,.06);\n    margin:14px 0;\n  }\n\n  .hvx-section-title{\n    margin:0 0 10px;\n    font-family:\"Anton\",\"Impact\",system-ui,-apple-system,BlinkMacSystemFont,\"Segoe UI\",sans-serif;\n    font-size:17px;\n    letter-spacing:.08em;\n    text-transform:uppercase;\n    color:var(--hvx-slate);\n    display:inline-flex;\n    align-items:center;\n    gap:8px;\n  }\n  .hvx-section-title::after{\n    content:\"\";\n    flex:1;\n    height:2px;\n    border-radius:999px;\n    background:linear-gradient(90deg,var(--hvx-golden),transparent);\n    opacity:.9;\n  }\n\n  .hvx-cta{display:flex;flex-wrap:wrap;gap:10px;margin:10px 0 0}\n  .hvx-cta a{\n    display:inline-flex;\n    align-items:center;\n    gap:8px;\n    padding:10px 14px;\n    border-radius:12px;\n    border:1px solid var(--hvx-border);\n    background:#fff;\n    text-decoration:none;\n    color:var(--hvx-slate);\n    font-size:14px;\n    font-weight:700;\n  }\n  .hvx-cta a.primary{\n    background:var(--hvx-slate);\n    color:#fff;\n    border-color:transparent;\n  }\n\n  .hvx-badges{display:flex;flex-wrap:wrap;gap:8px;margin:10px 0 0}\n  .hvx-badge{\n    font-size:12px;\n    border:1px solid var(--hvx-border);\n    border-radius:999px;\n    padding:6px 10px;\n    background:#fff;\n    white-space:nowrap;\n  }\n\n  .hvx-kv{\n    display:grid;\n    grid-template-columns:repeat(4,minmax(160px,1fr));\n    gap:10px;\n    margin-top:10px;\n  }\n  .hvx-kv \u003e div{\n    border:1px solid var(--hvx-border);\n    background:#fff;\n    border-radius:12px;\n    padding:10px 12px;\n    text-align:center;\n  }\n  .hvx-kv strong{display:block}\n\n  .hvx-table{\n    width:100%;\n    border-collapse:collapse;\n    min-width:520px;\n    background:#fff;\n    border:1px solid var(--hvx-border);\n    border-radius:12px;\n    overflow:hidden;\n  }\n  .hvx-table th,.hvx-table td{\n    border-bottom:1px solid var(--hvx-border);\n    padding:10px 12px;\n    vertical-align:top;\n    font-size:14px;\n  }\n  .hvx-table th{ text-align:left; font-weight:800; background:#fff; }\n  .hvx-table tr:nth-child(even) td{ background:#fbfaf6; }\n  .hvx-table tr:last-child td{ border-bottom:none; }\n  .hvx-table-wrap{ overflow:auto; border-radius:12px; }\n\n  .hvx-link{color:var(--hvx-slate); text-decoration:underline; text-underline-offset:2px}\n  .hvx-link:hover{opacity:.85}\n\n  details.hvx-faq{\n    border:1px solid var(--hvx-border);\n    background:#fff;\n    border-radius:12px;\n    padding:10px 12px;\n    margin:8px 0;\n  }\n  details.hvx-faq summary{cursor:pointer;font-weight:800}\n\n  @media(max-width:980px){\n    .hvx-kv{grid-template-columns:repeat(2,minmax(160px,1fr))}\n  }\n  @media(max-width:768px){\n    .hvx-desc{padding:14px 12px 16px;border-radius:12px}\n    .hvx-desc-header{padding:12px;border-radius:12px}\n    .hvx-title{font-size:19px}\n    .hvx-desc-card{padding:14px;margin:10px 0}\n  }\n\u003c\/style\u003e\n\u003cdiv class=\"hvx-desc\"\u003e\n\u003cdiv class=\"hvx-desc-header\"\u003e\n\u003cdiv class=\"hvx-header-text\"\u003e\n\u003cdiv class=\"hvx-eyebrow\"\u003eCooper\u0026amp;Hunter Olivia • R454B • Hyper Heat\u003c\/div\u003e\n\u003ch1 class=\"hvx-title\"\u003eCooper\u0026amp;Hunter 6,000 BTU Olivia Single Zone Wall Mount Mini Split Heat Pump System R454B 230V\u003c\/h1\u003e\n\u003cp class=\"hvx-subtitle\"\u003e\u003cstrong\u003eSKU:\u003c\/strong\u003e CH-R06MOLVWM-230VI + CH-RHP06F9-230VO\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv aria-label=\"Contact options\" class=\"hvx-cta\"\u003e\n\u003ca title=\"Contact Us\" rel=\"noopener\" href=\"https:\/\/hvacsupplies.com\/pages\/contact\" class=\"primary\" target=\"_blank\"\u003e CLICK HERE TO CONTACT US FOR CUSTOM QUOTES AND QUESTIONS \u003c\/a\u003e \u003ca title=\"Call Us Now!\" href=\"tel:+18005438933\"\u003eCLICK TO CALL US 800-543-8933 FOR ANY QUESTIONS\u003c\/a\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"hvx-desc-card\"\u003e\n\u003ch2 class=\"hvx-section-title\"\u003eOverview\u003c\/h2\u003e\n\u003cp style=\"margin: 0;\"\u003eEnhance your home's climate control with the Cooper\u0026amp;Hunter \u003cstrong\u003e6K BTU Olivia\u003c\/strong\u003e wall-mounted mini split—an efficient HVAC solution with \u003cstrong\u003eup to 25.3 SEER2\u003c\/strong\u003e performance and modern comfort features. Auto-swing horizontal louvers help circulate air evenly to reduce hot\/cold spots, while inverter technology supports quiet, efficient operation.\u003c\/p\u003e\n\u003cp style=\"margin: 10px 0 0;\"\u003ePaired with a \u003cstrong\u003eHyper Heating\u003c\/strong\u003e single-zone outdoor unit that operates in heating down to \u003cstrong\u003e−22°F\u003c\/strong\u003e, this system delivers dependable year-round comfort. Controls include \u003cstrong\u003eSmart Kit with C\u0026amp;H App\u003c\/strong\u003e connectivity, an included remote, and optional wall thermostat compatibility (sold separately).\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"hvx-desc-card\"\u003e\n\u003ch2 class=\"hvx-section-title\"\u003eHighlights\u003c\/h2\u003e\n\u003cdiv role=\"list\" class=\"hvx-badges\"\u003e\n\u003cspan role=\"listitem\" class=\"hvx-badge\"\u003e6,000 BTU class\u003c\/span\u003e \u003cspan role=\"listitem\" class=\"hvx-badge\"\u003eR454B refrigerant\u003c\/span\u003e \u003cspan role=\"listitem\" class=\"hvx-badge\"\u003eUp to 25.3 SEER2\u003c\/span\u003e \u003cspan role=\"listitem\" class=\"hvx-badge\"\u003eHyper Heat to −22°F (Outdoor)\u003c\/span\u003e \u003cspan role=\"listitem\" class=\"hvx-badge\"\u003e208–230V, 1Ph, 60Hz\u003c\/span\u003e \u003cspan role=\"listitem\" class=\"hvx-badge\"\u003eSmart Kit included (App control)\u003c\/span\u003e \u003cspan role=\"listitem\" class=\"hvx-badge\"\u003eAuto-swing (horizontal louvers)\u003c\/span\u003e \u003cspan role=\"listitem\" class=\"hvx-badge\"\u003eTurbo Mode\u003c\/span\u003e\n\u003c\/div\u003e\n\u003cul style=\"margin: 12px 0 0; padding-left: 18px;\"\u003e\n\u003cli\u003e\n\u003cstrong\u003eGenius Core inverter performance:\u003c\/strong\u003e ultra-low compressor speed support for efficient, quiet operation.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e46°F freeze protection:\u003c\/strong\u003e added protection in cold conditions.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRapid response:\u003c\/strong\u003e High-Frequency Racer Technology ramps to max speed quickly on startup.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSmarter comfort:\u003c\/strong\u003e Follow Me mode, Timer On\/Off, and Sleep Mode for personalized scheduling.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBuilt to last:\u003c\/strong\u003e TU1 copper tubes for efficient heat transfer and durability.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cdiv aria-label=\"At-a-glance\" role=\"list\" class=\"hvx-kv\"\u003e\n\u003cdiv role=\"listitem\"\u003e\n\u003cstrong\u003eIndoor\u003c\/strong\u003eCH-R06MOLVWM-230VI\u003c\/div\u003e\n\u003cdiv role=\"listitem\"\u003e\n\u003cstrong\u003eOutdoor\u003c\/strong\u003eCH-RHP06F9-230VO\u003c\/div\u003e\n\u003cdiv role=\"listitem\"\u003e\n\u003cstrong\u003eLines\u003c\/strong\u003e1\/4\" liquid · 3\/8\" gas\u003c\/div\u003e\n\u003cdiv role=\"listitem\"\u003e\n\u003cstrong\u003eMax run\u003c\/strong\u003e82 ft\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"hvx-desc-card\"\u003e\n\u003ch2 class=\"hvx-section-title\"\u003eWhat’s Included\u003c\/h2\u003e\n\u003cul style=\"padding-left: 18px; margin: 8px 0;\"\u003e\n\u003cli\u003eIndoor unit: CH-R06MOLVWM-230VI\u003c\/li\u003e\n\u003cli\u003eOutdoor unit: CH-RHP06F9-230VO (Hyper Heating)\u003c\/li\u003e\n\u003cli\u003eRemote control\u003c\/li\u003e\n\u003cli\u003eSmart Kit (app connectivity)\u003c\/li\u003e\n\u003cli\u003eManufacturer documentation (see Downloads)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"hvx-desc-card\"\u003e\n\u003ch2 class=\"hvx-section-title\"\u003eIndoor Specs\u003c\/h2\u003e\n\u003cdiv class=\"hvx-table-wrap\"\u003e\n\u003ctable aria-label=\"Indoor unit specifications\" class=\"hvx-table\"\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eSpec\u003c\/th\u003e\n\u003cth\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIndoor Model\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCH-R06MOLVWM-230VI\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower Supply (Rated)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e208\/230 V, 1 Ø, 60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Capacity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e6,000 Btu\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMinimum Circuit Ampacity (MCA)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMax. fuse (A)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e15\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIndoor Air Flow (Turbo\/Hi\/Med\/Lo\/Si) (CFM)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e294.3 \/ 235.4 \/ 176.6 \/ 141.3 \/ N\/A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIndoor Noise Level (Turbo\/Hi\/Med\/Lo\/Si) dB(A)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e42 \/ 37 \/ 32 \/ 24 \/ 20.5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimension (W×D×H) (in)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e28.70 × 7.8 × 11.50\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePacking (W×D×H) (in)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e31.10 × 10.63 × 14.76\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNet\/Gross Weight (lb)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e17.64 \/ 23.15\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRoom Temperature (Cooling) (°F)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e60–90\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRoom Temperature (Heating) (°F)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e32–86\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRefrigerant piping Liquid\/Gas side (inch)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1\/4\" \/ 3\/8\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"hvx-desc-card\"\u003e\n\u003ch2 class=\"hvx-section-title\"\u003eOutdoor Specs\u003c\/h2\u003e\n\u003cdiv class=\"hvx-table-wrap\"\u003e\n\u003ctable aria-label=\"Outdoor unit specifications\" class=\"hvx-table\" style=\"width: 100%; height: 694.109px;\"\u003e\n\u003cthead\u003e\n\u003ctr style=\"height: 22.3906px;\"\u003e\n\u003cth style=\"width: 67.2729%; height: 22.3906px;\"\u003eSpec\u003c\/th\u003e\n\u003cth style=\"width: 23.4375%; height: 22.3906px;\"\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr style=\"height: 44.7812px;\"\u003e\n\u003ctd style=\"width: 67.2729%; height: 44.7812px;\"\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 23.4375%; height: 44.7812px;\"\u003eCH-RHP06F9-230VO\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 22.3906px;\"\u003e\n\u003ctd style=\"width: 67.2729%; height: 22.3906px;\"\u003e\u003cstrong\u003eRefrigerant type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 23.4375%; height: 22.3906px;\"\u003eR454B\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 22.3906px;\"\u003e\n\u003ctd style=\"width: 67.2729%; height: 22.3906px;\"\u003e\u003cstrong\u003eBTU Rated\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 23.4375%; height: 22.3906px;\"\u003e6,000\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 44.7812px;\"\u003e\n\u003ctd style=\"width: 67.2729%; height: 44.7812px;\"\u003e\u003cstrong\u003ePower source\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 23.4375%; height: 44.7812px;\"\u003e208-230V, 1Ph, 60Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 22.3906px;\"\u003e\n\u003ctd style=\"width: 67.2729%; height: 22.3906px;\"\u003e\u003cstrong\u003eVoltage range (V)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 23.4375%; height: 22.3906px;\"\u003e187-253\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 22.3906px;\"\u003e\n\u003ctd style=\"width: 67.2729%; height: 22.3906px;\"\u003e\u003cstrong\u003eRefrigerant piping Liquid\/Gas side (inch)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 23.4375%; height: 22.3906px;\"\u003e1\/4\" \/ 3\/8\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 22.3906px;\"\u003e\n\u003ctd style=\"width: 67.2729%; height: 22.3906px;\"\u003e\u003cstrong\u003eMax. pipe length (ft)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 23.4375%; height: 22.3906px;\"\u003e82\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 22.3906px;\"\u003e\n\u003ctd style=\"width: 67.2729%; height: 22.3906px;\"\u003e\u003cstrong\u003eMax height difference between Indoor and Outdoor unit\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 23.4375%; height: 22.3906px;\"\u003e49.2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 44.7812px;\"\u003e\n\u003ctd style=\"width: 67.2729%; height: 44.7812px;\"\u003e\u003cstrong\u003eCooling capacity (Min\/Max) (BTU\/h)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 23.4375%; height: 44.7812px;\"\u003e6,000 (2,300~12,600)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 44.7812px;\"\u003e\n\u003ctd style=\"width: 67.2729%; height: 44.7812px;\"\u003e\u003cstrong\u003eHeating capacity (Min\/Max) (Btu\/h)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 23.4375%; height: 44.7812px;\"\u003e7,000 (3,000~11,000)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 22.3906px;\"\u003e\n\u003ctd style=\"width: 67.2729%; height: 22.3906px;\"\u003e\u003cstrong\u003eOutdoor Noise Level\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 23.4375%; height: 22.3906px;\"\u003e53\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 22.3906px;\"\u003e\n\u003ctd style=\"width: 67.2729%; height: 22.3906px;\"\u003e\u003cstrong\u003eOutdoor Air Flow\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 23.4375%; height: 22.3906px;\"\u003e1,235.3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 22.3906px;\"\u003e\n\u003ctd style=\"width: 67.2729%; height: 22.3906px;\"\u003e\u003cstrong\u003eMinimum circuit ampacity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 23.4375%; height: 22.3906px;\"\u003e12\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 22.3906px;\"\u003e\n\u003ctd style=\"width: 67.2729%; height: 22.3906px;\"\u003e\u003cstrong\u003eMax.fuse\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 23.4375%; height: 22.3906px;\"\u003e15\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 22.3906px;\"\u003e\n\u003ctd style=\"width: 67.2729%; height: 22.3906px;\"\u003e\u003cstrong\u003eHSPF2-5\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 23.4375%; height: 22.3906px;\"\u003e11.5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 22.3906px;\"\u003e\n\u003ctd style=\"width: 67.2729%; height: 22.3906px;\"\u003e\u003cstrong\u003eHSPF2-4\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 23.4375%; height: 22.3906px;\"\u003e14.8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 22.3906px;\"\u003e\n\u003ctd style=\"width: 67.2729%; height: 22.3906px;\"\u003e\u003cstrong\u003eCOP\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 23.4375%; height: 22.3906px;\"\u003e4.2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 22.3906px;\"\u003e\n\u003ctd style=\"width: 67.2729%; height: 22.3906px;\"\u003e\u003cstrong\u003eAmbient temperature - Heating (F)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 23.4375%; height: 22.3906px;\"\u003e-22~75\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 22.3906px;\"\u003e\n\u003ctd style=\"width: 67.2729%; height: 22.3906px;\"\u003e\u003cstrong\u003eAmbient temperature - Cooling (F)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 23.4375%; height: 22.3906px;\"\u003e-22 ~ 122\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 44.7812px;\"\u003e\n\u003ctd style=\"width: 67.2729%; height: 44.7812px;\"\u003e\u003cstrong\u003eUnit dimensions (W*H*D)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 23.4375%; height: 44.7812px;\"\u003e30.12 x 11.93 x 21.85\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 22.3906px;\"\u003e\n\u003ctd style=\"width: 67.2729%; height: 22.3906px;\"\u003e\u003cstrong\u003eUnit Net\/Gross weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 23.4375%; height: 22.3906px;\"\u003e62.17\/67.68\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 44.7812px;\"\u003e\n\u003ctd style=\"width: 67.2729%; height: 44.7812px;\"\u003e\u003cstrong\u003ePacking dimensions (WxDxH)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 23.4375%; height: 44.7812px;\"\u003e34.92 x 13.27 x 24.02\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 22.3906px;\"\u003e\n\u003ctd style=\"width: 67.2729%; height: 22.3906px;\"\u003e\u003cstrong\u003eRefrigerant precharge\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 23.4375%; height: 22.3906px;\"\u003e25\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 22.3906px;\"\u003e\n\u003ctd style=\"width: 67.2729%; height: 22.3906px;\"\u003e\u003cstrong\u003eAdditional Refrigerant Charge 1\/4 liquid line\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 23.4375%; height: 22.3906px;\"\u003e0.16\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"hvx-desc-card\"\u003e\n\u003ch2 class=\"hvx-section-title\"\u003eDocuments \u0026amp; Downloads\u003c\/h2\u003e\n\u003cul style=\"padding-left: 18px; margin: 8px 0;\"\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/media.cooperandhunter.us\/4761\/CH-RHP06F9-230VO_CH-R06MOLVWM-230VI.pdf\" target=\"_blank\" rel=\"noopener\"\u003eSubmittal (PDF): CH-R06MOLVWM-230VI (Link 1)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca rel=\"noopener\" href=\"https:\/\/media.cooperandhunter.us\/4154\/CH-RHP06F9-230VO-%2B-CH-PRO06MASTWM-230VI.pdf\" class=\"hvx-link\" target=\"_blank\"\u003eSubmittal (PDF): CH-RHP06F9-230VO + CH-PRO06MASTWM-230VI\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca rel=\"noopener\" href=\"https:\/\/media.cooperandhunter.us\/4165\/CH-RHP06F9-230VO-%2B-CH-RH06MASTWM-230VI.pdf\" class=\"hvx-link\" target=\"_blank\"\u003eSubmittal (PDF): CH-RHP06F9-230VO + CH-RH06MASTWM-230VI\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca rel=\"noopener\" href=\"https:\/\/media.cooperandhunter.us\/4201\/CH-RHP06F9-230VO-%2B-CH-RS06-12MDT--MS.pdf\" class=\"hvx-link\" target=\"_blank\"\u003eSubmittal (PDF): CH-RHP06F9-230VO + CH-RS06-12MDT--MS\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca rel=\"noopener\" href=\"https:\/\/media.cooperandhunter.us\/4118\/Installation-Manual-R454B-Outdoor-units--.pdf\" class=\"hvx-link\" target=\"_blank\"\u003eInstallation Manual (PDF): R454B Outdoor Units\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca rel=\"noopener\" href=\"https:\/\/media.cooperandhunter.us\/4200\/SlimDuct-Leaflet-R454B.pdf\" class=\"hvx-link\" target=\"_blank\"\u003eLeaflet (PDF): SlimDuct — R454B\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca rel=\"noopener\" href=\"https:\/\/cooperandhunter.us\/product\/ch-rhp06f9-230vo\" class=\"hvx-link\" target=\"_blank\"\u003eManufacturer Page: CH-RHP06F9-230VO\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca rel=\"noopener\" href=\"https:\/\/www.ahridirectory.org\" class=\"hvx-link\" target=\"_blank\"\u003eAHRI Directory Listing: 215864151\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"hvx-desc-card\"\u003e\n\u003ch2 class=\"hvx-section-title\"\u003eImportant\u003c\/h2\u003e\n\u003cp style=\"margin: 0; font-size: 14px; color: var(--hvx-slate);\"\u003eProfessional installation is recommended. Confirm electrical requirements, line sizes, maximum line length, and ambient operating limits before installation.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"hvx-desc-card\"\u003e\n\u003ch2 class=\"hvx-section-title\"\u003eFAQs\u003c\/h2\u003e\n\u003cdetails open=\"\" class=\"hvx-faq\"\u003e\n\u003csummary\u003eIs this system Hyper Heat?\u003c\/summary\u003e\n\u003cdiv style=\"margin-top: 8px;\"\u003eYes—Hyper Heating operation is rated down to −22°F.\u003c\/div\u003e\n\u003c\/details\u003e\n\u003cdetails open=\"\" class=\"hvx-faq\"\u003e\n\u003csummary\u003eWhat line sizes does this system use?\u003c\/summary\u003e\n\u003cdiv style=\"margin-top: 8px;\"\u003e1\/4\" liquid and 3\/8\" gas.\u003c\/div\u003e\n\u003c\/details\u003e\n\u003cdetails open=\"\" class=\"hvx-faq\"\u003e\n\u003csummary\u003eDoes it include smart control?\u003c\/summary\u003e\n\u003cdiv style=\"margin-top: 8px;\"\u003eYes—Smart Kit is included for C\u0026amp;H app control, and a remote is included.\u003c\/div\u003e\n\u003c\/details\u003e\n\u003cdetails open=\"\" class=\"hvx-faq\"\u003e\n\u003csummary\u003eWhat comfort modes are included?\u003c\/summary\u003e\n\u003cdiv style=\"margin-top: 8px;\"\u003eTurbo Mode, Follow Me, Timer On\/Off, Sleep Mode, and 46°F Freeze Protection.\u003c\/div\u003e\n\u003c\/details\u003e\n\u003cdetails open=\"\" class=\"hvx-faq\"\u003e\n\u003csummary\u003eIs a wall thermostat supported?\u003c\/summary\u003e\n\u003cdiv style=\"margin-top: 8px;\"\u003eYes—wall thermostat compatibility is available (thermostat sold separately).\u003c\/div\u003e\n\u003c\/details\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e","brand":"Cooper\u0026Hunter","offers":[{"title":"No installation","offer_id":42672972791851,"sku":"CH-R06MOLVWM-230VI + CH-RHP06F9-230VO","price":1380.0,"currency_code":"USD","in_stock":true},{"title":"16FT","offer_id":42672972824619,"sku":"CH-R06MOLVWM-230VI + CH-RHP06F9-230VO","price":1561.0,"currency_code":"USD","in_stock":true},{"title":"25FT","offer_id":42672972857387,"sku":"CH-R06MOLVWM-230VI + CH-RHP06F9-230VO","price":1607.0,"currency_code":"USD","in_stock":true},{"title":"50FT","offer_id":42672972890155,"sku":"CH-R06MOLVWM-230VI + CH-RHP06F9-230VO","price":1828.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0625\/5647\/1339\/files\/5_aef7a478-a314-4dcb-ab91-aa8b5cc28844.png?v=1769199804"},{"product_id":"cooper-hunter-9-000-btu-olivia-hyper-single-zone-wall-mount-minisplit-heat-pump-system-r454b-230v","title":"Cooper\u0026Hunter 9,000 BTU Olivia Hyper Single Zone Wall Mount Minisplit Heat Pump System R454B 230V","description":"\u003cstyle\u003e\n  :root{\n    --hvx-golden:#FAA819;\n    --hvx-slate:#262626;\n    --hvx-ivory:#F4F1E6;\n    --hvx-border:#e2e0d5;\n    --hvx-card-bg:#ffffff;\n  }\n\n  .hvx-desc{\n    font-family:\"Articulat CF\",system-ui,-apple-system,BlinkMacSystemFont,\"Segoe UI\",sans-serif;\n    color:var(--hvx-slate);\n    line-height:1.6;\n    background:var(--hvx-ivory);\n    padding:18px 18px 20px;\n    border-radius:16px;\n  }\n\n  .hvx-desc-header{\n    border-radius:14px;\n    padding:14px 16px;\n    background:linear-gradient(120deg,var(--hvx-golden),var(--hvx-slate));\n    color:#fff;\n    margin:0 0 16px;\n    box-shadow:0 10px 24px rgba(0,0,0,.22);\n    display:flex;\n    align-items:flex-start;\n    gap:12px;\n    flex-wrap:wrap;\n  }\n\n  .hvx-header-text{display:flex;flex-direction:column;gap:6px;min-width:260px}\n  .hvx-eyebrow{\n    font-size:11px;\n    letter-spacing:.14em;\n    text-transform:uppercase;\n    opacity:.9;\n  }\n  .hvx-title{\n    margin:0;\n    font-family:\"Anton\",\"Impact\",system-ui,-apple-system,BlinkMacSystemFont,\"Segoe UI\",sans-serif;\n    font-size:22px;\n    line-height:1.15;\n  }\n  .hvx-subtitle{margin:0;font-size:14px;opacity:.95}\n\n  .hvx-desc-card{\n    border:1px solid var(--hvx-border);\n    border-radius:14px;\n    background:var(--hvx-card-bg);\n    padding:16px 18px 18px;\n    box-shadow:0 4px 12px rgba(0,0,0,.06);\n    margin:14px 0;\n  }\n\n  .hvx-section-title{\n    margin:0 0 10px;\n    font-family:\"Anton\",\"Impact\",system-ui,-apple-system,BlinkMacSystemFont,\"Segoe UI\",sans-serif;\n    font-size:17px;\n    letter-spacing:.08em;\n    text-transform:uppercase;\n    color:var(--hvx-slate);\n    display:inline-flex;\n    align-items:center;\n    gap:8px;\n  }\n  .hvx-section-title::after{\n    content:\"\";\n    flex:1;\n    height:2px;\n    border-radius:999px;\n    background:linear-gradient(90deg,var(--hvx-golden),transparent);\n    opacity:.9;\n  }\n\n  .hvx-cta{display:flex;flex-wrap:wrap;gap:10px;margin:10px 0 0}\n  .hvx-cta a{\n    display:inline-flex;\n    align-items:center;\n    gap:8px;\n    padding:10px 14px;\n    border-radius:12px;\n    border:1px solid var(--hvx-border);\n    background:#fff;\n    text-decoration:none;\n    color:var(--hvx-slate);\n    font-size:14px;\n    font-weight:700;\n  }\n  .hvx-cta a.primary{\n    background:var(--hvx-slate);\n    color:#fff;\n    border-color:transparent;\n  }\n\n  .hvx-badges{display:flex;flex-wrap:wrap;gap:8px;margin:10px 0 0}\n  .hvx-badge{\n    font-size:12px;\n    border:1px solid var(--hvx-border);\n    border-radius:999px;\n    padding:6px 10px;\n    background:#fff;\n    white-space:nowrap;\n  }\n\n  .hvx-kv{\n    display:grid;\n    grid-template-columns:repeat(4,minmax(160px,1fr));\n    gap:10px;\n    margin-top:10px;\n  }\n  .hvx-kv \u003e div{\n    border:1px solid var(--hvx-border);\n    background:#fff;\n    border-radius:12px;\n    padding:10px 12px;\n    text-align:center;\n  }\n  .hvx-kv strong{display:block}\n\n  .hvx-table{\n    width:100%;\n    border-collapse:collapse;\n    min-width:520px;\n    background:#fff;\n    border:1px solid var(--hvx-border);\n    border-radius:12px;\n    overflow:hidden;\n  }\n  .hvx-table th,.hvx-table td{\n    border-bottom:1px solid var(--hvx-border);\n    padding:10px 12px;\n    vertical-align:top;\n    font-size:14px;\n  }\n  .hvx-table th{ text-align:left; font-weight:800; background:#fff; }\n  .hvx-table tr:nth-child(even) td{ background:#fbfaf6; }\n  .hvx-table tr:last-child td{ border-bottom:none; }\n  .hvx-table-wrap{ overflow:auto; border-radius:12px; }\n\n  .hvx-link{color:var(--hvx-slate); text-decoration:underline; text-underline-offset:2px}\n  .hvx-link:hover{opacity:.85}\n\n  details.hvx-faq{\n    border:1px solid var(--hvx-border);\n    background:#fff;\n    border-radius:12px;\n    padding:10px 12px;\n    margin:8px 0;\n  }\n  details.hvx-faq summary{cursor:pointer;font-weight:800}\n\n  @media(max-width:980px){\n    .hvx-kv{grid-template-columns:repeat(2,minmax(160px,1fr))}\n  }\n  @media(max-width:768px){\n    .hvx-desc{padding:14px 12px 16px;border-radius:12px}\n    .hvx-desc-header{padding:12px;border-radius:12px}\n    .hvx-title{font-size:19px}\n    .hvx-desc-card{padding:14px;margin:10px 0}\n  }\n\u003c\/style\u003e\n\u003cdiv class=\"hvx-desc\"\u003e\n\u003cdiv class=\"hvx-desc-header\"\u003e\n\u003cdiv class=\"hvx-header-text\"\u003e\n\u003cdiv class=\"hvx-eyebrow\"\u003eCooper\u0026amp;Hunter Olivia • R454B • Hyper Heat\u003c\/div\u003e\n\u003ch1 class=\"hvx-title\"\u003eCooper\u0026amp;Hunter 9,000 BTU Olivia Single Zone Wall Mount Mini Split Heat Pump System R454B 230V\u003c\/h1\u003e\n\u003cp class=\"hvx-subtitle\"\u003e\u003cstrong\u003eSKU:\u003c\/strong\u003e CH-R09MOLVWM-230VI + CH-RHP09-230VO\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"hvx-cta\" aria-label=\"Contact options\"\u003e\n\u003ca class=\"primary\" href=\"https:\/\/hvacsupplies.com\/pages\/contact\" rel=\"noopener\" title=\"Contact Us\" target=\"_blank\"\u003e CLICK HERE TO CONTACT US FOR CUSTOM QUOTES AND QUESTIONS \u003c\/a\u003e \u003ca href=\"tel:+18005438933\" title=\"Call Us Now!\"\u003eCLICK TO CALL US 800-543-8933 FOR ANY QUESTIONS\u003c\/a\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"hvx-desc-card\"\u003e\n\u003ch2 class=\"hvx-section-title\"\u003eOverview\u003c\/h2\u003e\n\u003cp style=\"margin: 0;\"\u003eEnhance your home's climate control with the Cooper\u0026amp;Hunter \u003cstrong\u003e9K BTU Olivia\u003c\/strong\u003e wall-mounted mini split utilizing \u003cstrong\u003eR454B\u003c\/strong\u003e refrigerant for strong efficiency and a lower environmental impact. With \u003cstrong\u003eup to 26.0 SEER2\u003c\/strong\u003e efficiency, this 230V system delivers modern comfort features built for everyday convenience.\u003c\/p\u003e\n\u003cp style=\"margin: 10px 0 0;\"\u003eAuto-swing horizontal louvers help distribute air evenly to reduce hot and cold spots, while advanced inverter technology supports quiet, efficient operation. This system pairs with a \u003cstrong\u003eHyper Heating\u003c\/strong\u003e single-zone outdoor unit for reliable heating performance down to \u003cstrong\u003e−22°F\u003c\/strong\u003e. Controls include Smart Kit app connectivity through the C\u0026amp;H app, an included remote, and optional wall thermostat compatibility (sold separately).\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"hvx-desc-card\"\u003e\n\u003ch2 class=\"hvx-section-title\"\u003eHighlights\u003c\/h2\u003e\n\u003cdiv class=\"hvx-badges\" role=\"list\"\u003e\n\u003cspan class=\"hvx-badge\" role=\"listitem\"\u003e9,000 BTU class\u003c\/span\u003e \u003cspan class=\"hvx-badge\" role=\"listitem\"\u003eR454B refrigerant\u003c\/span\u003e \u003cspan class=\"hvx-badge\" role=\"listitem\"\u003eUp to 26.0 SEER2\u003c\/span\u003e \u003cspan class=\"hvx-badge\" role=\"listitem\"\u003eHyper Heat to −22°F (Outdoor)\u003c\/span\u003e \u003cspan class=\"hvx-badge\" role=\"listitem\"\u003e208–230V, 1Ph, 60Hz\u003c\/span\u003e \u003cspan class=\"hvx-badge\" role=\"listitem\"\u003eSmart Kit included (App control)\u003c\/span\u003e \u003cspan class=\"hvx-badge\" role=\"listitem\"\u003eAuto-swing (horizontal louvers)\u003c\/span\u003e \u003cspan class=\"hvx-badge\" role=\"listitem\"\u003eTurbo Mode\u003c\/span\u003e\n\u003c\/div\u003e\n\u003cul style=\"margin: 12px 0 0; padding-left: 18px;\"\u003e\n\u003cli\u003e\n\u003cstrong\u003eGenius Core inverter performance:\u003c\/strong\u003e ultra-low compressor speed support for quiet, efficient operation.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e46°F freeze protection:\u003c\/strong\u003e added protection for cold conditions.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHigh-Frequency Racer Technology:\u003c\/strong\u003e rapid ramp to maximum speed on startup for quick comfort.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAdvanced refrigerant management:\u003c\/strong\u003e electronic expansion valve optimizes refrigerant flow control.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCleaner performance:\u003c\/strong\u003e intelligent dusting switch reverses the fan to help clear dust, sand, and debris from the coil.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eComfort automation:\u003c\/strong\u003e Follow Me, Timer On\/Off, and Sleep Mode for personalized scheduling.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cdiv class=\"hvx-kv\" role=\"list\" aria-label=\"At-a-glance\"\u003e\n\u003cdiv role=\"listitem\"\u003e\n\u003cstrong\u003eIndoor\u003c\/strong\u003eCH-R09MOLVWM-230VI\u003c\/div\u003e\n\u003cdiv role=\"listitem\"\u003e\n\u003cstrong\u003eOutdoor\u003c\/strong\u003eCH-RHP09-230VO\u003c\/div\u003e\n\u003cdiv role=\"listitem\"\u003e\n\u003cstrong\u003eLines\u003c\/strong\u003e1\/4\" liquid · 3\/8\" gas\u003c\/div\u003e\n\u003cdiv role=\"listitem\"\u003e\n\u003cstrong\u003eMax run\u003c\/strong\u003e82 ft\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"hvx-desc-card\"\u003e\n\u003ch2 class=\"hvx-section-title\"\u003eWhat’s Included\u003c\/h2\u003e\n\u003cul style=\"padding-left: 18px; margin: 8px 0;\"\u003e\n\u003cli\u003eIndoor unit: CH-R09MOLVWM-230VI\u003c\/li\u003e\n\u003cli\u003eOutdoor unit: CH-RHP09-230VO (Hyper Heating)\u003c\/li\u003e\n\u003cli\u003eRemote control\u003c\/li\u003e\n\u003cli\u003eSmart Kit (app connectivity)\u003c\/li\u003e\n\u003cli\u003eManufacturer documentation (see Downloads)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"hvx-desc-card\"\u003e\n\u003ch2 class=\"hvx-section-title\"\u003eIndoor Specs\u003c\/h2\u003e\n\u003cdiv class=\"hvx-table-wrap\"\u003e\n\u003ctable class=\"hvx-table\" aria-label=\"Indoor unit specifications\"\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eSpec\u003c\/th\u003e\n\u003cth\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIndoor Model\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCH-R09MOLVWM-230VI\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower Supply (Rated)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e208\/230 V, 1 Ø, 60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Capacity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e9,000 Btu\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMinimum Circuit Ampacity (MCA)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMax. fuse (A)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e15\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIndoor Air Flow (Turbo\/Hi\/Med\/Lo\/Si) (CFM)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e382.6 \/ 294.3 \/ 194.2 \/ 153.0 \/ N\/A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIndoor Noise Level (Turbo\/Hi\/Med\/Lo\/Si) dB(A)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eN\/A \/ 39.5 \/ 33 \/ 24 \/ 20.5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimension (W×D×H) (in)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e31.57 × 7.87 × 11.61\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePacking (W×D×H) (in)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e31.57 × 7.87 × 11.61\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNet\/Gross Weight (lb)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e18.96 \/ 24.25\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRoom Temperature (Cooling) (°F)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e60–90\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRoom Temperature (Heating) (°F)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e32–86\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRefrigerant piping Liquid\/Gas side (inch)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1\/4\" \/ 3\/8\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"hvx-desc-card\"\u003e\n\u003ch2 class=\"hvx-section-title\"\u003eOutdoor Specs\u003c\/h2\u003e\n\u003cdiv class=\"hvx-table-wrap\"\u003e\n\u003ctable class=\"hvx-table\" aria-label=\"Outdoor unit specifications\"\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eSpec\u003c\/th\u003e\n\u003cth\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCH-RHP09-230VO\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRefrigerant type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eR454B\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBTU Rated\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e9,000\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower source\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e208-230V, 1Ph, 60Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eVoltage range (V)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e187-253\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRefrigerant piping Liquid\/Gas side (inch)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1\/4\" \/ 3\/8\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMax. pipe length (ft)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e82\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMax height difference between Indoor and Outdoor unit\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e49.2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCooling capacity (Min\/Max) (BTU\/h)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e9,000 (3,800~13,500)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eHeating capacity (Min\/Max) (Btu\/h)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e12,000 (3,800~16,000)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOutdoor Noise Level\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e56\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOutdoor Air Flow\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1,470.6\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMinimum circuit ampacity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e15\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMax.fuse\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e15\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eHSPF2-5\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e9.5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eHSPF2-4\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e12.5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCOP\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3.76\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAmbient temperature - Heating (F)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-22~75\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAmbient temperature - Cooling (F)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-22 ~ 122\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eUnit dimensions (W*H*D)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e31.69 x 12.99 x 21.81\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eUnit Net\/Gross weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e72.75\/78.70\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePacking dimensions (WxDxH)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e36.02 x 14.57 x 24.21\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRefrigerant precharge\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e25\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAdditional Refrigerant Charge 1\/4 liquid line\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.16\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"hvx-desc-card\"\u003e\n\u003ch2 class=\"hvx-section-title\"\u003eDocuments \u0026amp; Downloads\u003c\/h2\u003e\n\u003cul style=\"padding-left: 18px; margin: 8px 0;\"\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/media.cooperandhunter.us\/4728\/CH-RES09-230VO_CH-R09MOLVWM-230VI.pdf\" target=\"_blank\" rel=\"noopener\"\u003eSubmittal (PDF): CH-R09MOLVWM-230VI (Link 1)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca class=\"hvx-link\" href=\"https:\/\/drive.google.com\/file\/d\/11uCRDvBhIcMpwvzipwSXF-SzHNnvy1ty\/view?usp=drive_link\" rel=\"noopener\" target=\"_blank\"\u003eSubmittal (PDF): CH-R09MOLVWM-230VI (Link 2)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca class=\"hvx-link\" href=\"https:\/\/media.cooperandhunter.us\/4155\/CH-RHP09-230VO-%2B-CH-PRO09MASTWM-230VI.pdf\" rel=\"noopener\" target=\"_blank\"\u003eSubmittal (PDF): CH-RHP09-230VO + CH-PRO09MASTWM-230VI\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca class=\"hvx-link\" href=\"https:\/\/media.cooperandhunter.us\/4168\/CH-RHP09-230VO-%2B-CH-RH09MASTWM-230VI.pdf\" rel=\"noopener\" target=\"_blank\"\u003eSubmittal (PDF): CH-RHP09-230VO + CH-RH09MASTWM-230VI\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca class=\"hvx-link\" href=\"https:\/\/media.cooperandhunter.us\/4202\/CH-RHP09-230VO-%2B-CH-RS06-12MDT--MS.pdf\" rel=\"noopener\" target=\"_blank\"\u003eSubmittal (PDF): CH-RHP09-230VO + CH-RS06-12MDT--MS\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca class=\"hvx-link\" href=\"https:\/\/media.cooperandhunter.us\/4683\/CH-RHP09-230VO_CH-RSH09MCT.pdf\" rel=\"noopener\" target=\"_blank\"\u003eSubmittal (PDF): CH-RHP09-230VO + CH-RSH09MCT\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca class=\"hvx-link\" href=\"https:\/\/media.cooperandhunter.us\/4682\/CH-RHP09-230VO_CH-RH09MCT.pdf\" rel=\"noopener\" target=\"_blank\"\u003eSubmittal (PDF): CH-RHP09-230VO + CH-RH09MCT\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca class=\"hvx-link\" href=\"https:\/\/media.cooperandhunter.us\/4118\/Installation-Manual-R454B-Outdoor-units--.pdf\" rel=\"noopener\" target=\"_blank\"\u003eInstallation Manual (PDF): R454B Outdoor Units\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca class=\"hvx-link\" href=\"https:\/\/media.cooperandhunter.us\/4200\/SlimDuct-Leaflet-R454B.pdf\" rel=\"noopener\" target=\"_blank\"\u003eLeaflet (PDF): SlimDuct — R454B\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca class=\"hvx-link\" href=\"https:\/\/cooperandhunter.us\/product\/ch-rhp09-230vo\" rel=\"noopener\" target=\"_blank\"\u003eManufacturer Page: CH-RHP09-230VO\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca class=\"hvx-link\" href=\"https:\/\/www.ahridirectory.org\" rel=\"noopener\" target=\"_blank\"\u003eAHRI Directory Listing: 207742320\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"hvx-desc-card\"\u003e\n\u003ch2 class=\"hvx-section-title\"\u003eImportant\u003c\/h2\u003e\n\u003cp style=\"margin: 0; font-size: 14px; color: var(--hvx-slate);\"\u003eProfessional installation is recommended. Confirm electrical requirements, line sizes, maximum line length, and ambient operating limits before installation.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"hvx-desc-card\"\u003e\n\u003ch2 class=\"hvx-section-title\"\u003eFAQs\u003c\/h2\u003e\n\u003cdetails class=\"hvx-faq\" open=\"\"\u003e\n\u003csummary\u003eIs this system Hyper Heat?\u003c\/summary\u003e\n\u003cdiv style=\"margin-top: 8px;\"\u003eYes—Hyper Heating operation is rated down to −22°F.\u003c\/div\u003e\n\u003c\/details\u003e\n\u003cdetails class=\"hvx-faq\" open=\"\"\u003e\n\u003csummary\u003eWhat line sizes does this system use?\u003c\/summary\u003e\n\u003cdiv style=\"margin-top: 8px;\"\u003e1\/4\" liquid and 3\/8\" gas.\u003c\/div\u003e\n\u003c\/details\u003e\n\u003cdetails class=\"hvx-faq\" open=\"\"\u003e\n\u003csummary\u003eDoes it include smart control?\u003c\/summary\u003e\n\u003cdiv style=\"margin-top: 8px;\"\u003eYes—Smart Kit is included for C\u0026amp;H app control, and a remote is included.\u003c\/div\u003e\n\u003c\/details\u003e\n\u003cdetails class=\"hvx-faq\" open=\"\"\u003e\n\u003csummary\u003eWhat comfort modes are included?\u003c\/summary\u003e\n\u003cdiv style=\"margin-top: 8px;\"\u003eTurbo Mode, Follow Me, Timer On\/Off, Sleep Mode, and 46°F Freeze Protection.\u003c\/div\u003e\n\u003c\/details\u003e\n\u003cdetails class=\"hvx-faq\" open=\"\"\u003e\n\u003csummary\u003eIs a wall thermostat supported?\u003c\/summary\u003e\n\u003cdiv style=\"margin-top: 8px;\"\u003eYes—wall thermostat compatibility is available (thermostat sold separately).\u003c\/div\u003e\n\u003c\/details\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e","brand":"Cooper\u0026Hunter","offers":[{"title":"No installation","offer_id":42672999563307,"sku":"CH-R09MOLVWM-230VI +  CH-RHP09-230VO","price":1503.0,"currency_code":"USD","in_stock":true},{"title":"16FT","offer_id":42672999596075,"sku":"CH-R09MOLVWM-230VI +  CH-RHP09-230VO","price":1684.0,"currency_code":"USD","in_stock":true},{"title":"25FT","offer_id":42672999628843,"sku":"CH-R09MOLVWM-230VI +  CH-RHP09-230VO","price":1731.0,"currency_code":"USD","in_stock":true},{"title":"50FT","offer_id":42672999661611,"sku":"CH-R09MOLVWM-230VI +  CH-RHP09-230VO","price":1951.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0625\/5647\/1339\/files\/1_91be9011-04fa-4032-8e15-d1ef63412eb0.png?v=1768107224"},{"product_id":"cooper-hunter-12-000-btu-olivia-hyper-single-zone-wall-mount-minisplit-heat-pump-system-r454b-230v","title":"Cooper\u0026Hunter 12,000 BTU Olivia Hyper Single Zone Wall Mount Minisplit Heat Pump System R454B 230V","description":"\u003cstyle\u003e\n  :root{\n    --hvx-golden:#FAA819;\n    --hvx-slate:#262626;\n    --hvx-ivory:#F4F1E6;\n    --hvx-border:#e2e0d5;\n    --hvx-card-bg:#ffffff;\n  }\n\n  .hvx-desc{\n    font-family:\"Articulat CF\",system-ui,-apple-system,BlinkMacSystemFont,\"Segoe UI\",sans-serif;\n    color:var(--hvx-slate);\n    line-height:1.6;\n    background:var(--hvx-ivory);\n    padding:18px 18px 20px;\n    border-radius:16px;\n  }\n\n  .hvx-desc-header{\n    border-radius:14px;\n    padding:14px 16px;\n    background:linear-gradient(120deg,var(--hvx-golden),var(--hvx-slate));\n    color:#fff;\n    margin:0 0 16px;\n    box-shadow:0 10px 24px rgba(0,0,0,.22);\n    display:flex;\n    align-items:flex-start;\n    gap:12px;\n    flex-wrap:wrap;\n  }\n\n  .hvx-header-text{display:flex;flex-direction:column;gap:6px;min-width:260px}\n  .hvx-eyebrow{\n    font-size:11px;\n    letter-spacing:.14em;\n    text-transform:uppercase;\n    opacity:.9;\n  }\n  .hvx-title{\n    margin:0;\n    font-family:\"Anton\",\"Impact\",system-ui,-apple-system,BlinkMacSystemFont,\"Segoe UI\",sans-serif;\n    font-size:22px;\n    line-height:1.15;\n  }\n  .hvx-subtitle{margin:0;font-size:14px;opacity:.95}\n\n  .hvx-desc-card{\n    border:1px solid var(--hvx-border);\n    border-radius:14px;\n    background:var(--hvx-card-bg);\n    padding:16px 18px 18px;\n    box-shadow:0 4px 12px rgba(0,0,0,.06);\n    margin:14px 0;\n  }\n\n  .hvx-section-title{\n    margin:0 0 10px;\n    font-family:\"Anton\",\"Impact\",system-ui,-apple-system,BlinkMacSystemFont,\"Segoe UI\",sans-serif;\n    font-size:17px;\n    letter-spacing:.08em;\n    text-transform:uppercase;\n    color:var(--hvx-slate);\n    display:inline-flex;\n    align-items:center;\n    gap:8px;\n  }\n  .hvx-section-title::after{\n    content:\"\";\n    flex:1;\n    height:2px;\n    border-radius:999px;\n    background:linear-gradient(90deg,var(--hvx-golden),transparent);\n    opacity:.9;\n  }\n\n  .hvx-cta{display:flex;flex-wrap:wrap;gap:10px;margin:10px 0 0}\n  .hvx-cta a{\n    display:inline-flex;\n    align-items:center;\n    gap:8px;\n    padding:10px 14px;\n    border-radius:12px;\n    border:1px solid var(--hvx-border);\n    background:#fff;\n    text-decoration:none;\n    color:var(--hvx-slate);\n    font-size:14px;\n    font-weight:700;\n  }\n  .hvx-cta a.primary{\n    background:var(--hvx-slate);\n    color:#fff;\n    border-color:transparent;\n  }\n\n  .hvx-badges{display:flex;flex-wrap:wrap;gap:8px;margin:10px 0 0}\n  .hvx-badge{\n    font-size:12px;\n    border:1px solid var(--hvx-border);\n    border-radius:999px;\n    padding:6px 10px;\n    background:#fff;\n    white-space:nowrap;\n  }\n\n  .hvx-kv{\n    display:grid;\n    grid-template-columns:repeat(4,minmax(160px,1fr));\n    gap:10px;\n    margin-top:10px;\n  }\n  .hvx-kv \u003e div{\n    border:1px solid var(--hvx-border);\n    background:#fff;\n    border-radius:12px;\n    padding:10px 12px;\n    text-align:center;\n  }\n  .hvx-kv strong{display:block}\n\n  .hvx-table{\n    width:100%;\n    border-collapse:collapse;\n    min-width:520px;\n    background:#fff;\n    border:1px solid var(--hvx-border);\n    border-radius:12px;\n    overflow:hidden;\n  }\n  .hvx-table th,.hvx-table td{\n    border-bottom:1px solid var(--hvx-border);\n    padding:10px 12px;\n    vertical-align:top;\n    font-size:14px;\n  }\n  .hvx-table th{ text-align:left; font-weight:800; background:#fff; }\n  .hvx-table tr:nth-child(even) td{ background:#fbfaf6; }\n  .hvx-table tr:last-child td{ border-bottom:none; }\n  .hvx-table-wrap{ overflow:auto; border-radius:12px; }\n\n  .hvx-link{color:var(--hvx-slate); text-decoration:underline; text-underline-offset:2px}\n  .hvx-link:hover{opacity:.85}\n\n  details.hvx-faq{\n    border:1px solid var(--hvx-border);\n    background:#fff;\n    border-radius:12px;\n    padding:10px 12px;\n    margin:8px 0;\n  }\n  details.hvx-faq summary{cursor:pointer;font-weight:800}\n\n  @media(max-width:980px){\n    .hvx-kv{grid-template-columns:repeat(2,minmax(160px,1fr))}\n  }\n  @media(max-width:768px){\n    .hvx-desc{padding:14px 12px 16px;border-radius:12px}\n    .hvx-desc-header{padding:12px;border-radius:12px}\n    .hvx-title{font-size:19px}\n    .hvx-desc-card{padding:14px;margin:10px 0}\n  }\n\u003c\/style\u003e\n\u003cdiv class=\"hvx-desc\"\u003e\n\u003cdiv class=\"hvx-desc-header\"\u003e\n\u003cdiv class=\"hvx-header-text\"\u003e\n\u003cdiv class=\"hvx-eyebrow\"\u003eCooper\u0026amp;Hunter Olivia • R454B • Hyper Heat\u003c\/div\u003e\n\u003ch1 class=\"hvx-title\"\u003eCooper\u0026amp;Hunter 12,000 BTU Olivia Single Zone Wall Mount Mini Split Heat Pump System R454B 230V\u003c\/h1\u003e\n\u003cp class=\"hvx-subtitle\"\u003e\u003cstrong\u003eSKU:\u003c\/strong\u003e CH-R12MOLVWM-230VI + CH-RHP12-230VO\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"hvx-cta\" aria-label=\"Contact options\"\u003e\n\u003ca class=\"primary\" href=\"https:\/\/hvacsupplies.com\/pages\/contact\" rel=\"noopener\" title=\"Contact Us\" target=\"_blank\"\u003e CLICK HERE TO CONTACT US FOR CUSTOM QUOTES AND QUESTIONS \u003c\/a\u003e \u003ca href=\"tel:+18005438933\" title=\"Call Us Now!\"\u003eCLICK TO CALL US 800-543-8933 FOR ANY QUESTIONS\u003c\/a\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"hvx-desc-card\"\u003e\n\u003ch2 class=\"hvx-section-title\"\u003eOverview\u003c\/h2\u003e\n\u003cp style=\"margin: 0;\"\u003eEnhance your home's climate control with the Cooper\u0026amp;Hunter \u003cstrong\u003e12K BTU Olivia\u003c\/strong\u003e wall-mounted mini split utilizing \u003cstrong\u003eR454B\u003c\/strong\u003e refrigerant for improved efficiency and a lower environmental impact. With \u003cstrong\u003eup to 24.0 SEER2\u003c\/strong\u003e efficiency, this 230V system combines modern comfort features with dependable performance for medium-sized spaces.\u003c\/p\u003e\n\u003cp style=\"margin: 10px 0 0;\"\u003eAuto-swing horizontal louvers help distribute air evenly, while inverter technology supports quiet, efficient operation. Paired with a \u003cstrong\u003eHyper Heating\u003c\/strong\u003e outdoor unit designed for cold climates, this system delivers reliable heating performance down to \u003cstrong\u003e−22°F\u003c\/strong\u003e. Controls include Smart Kit app connectivity through the C\u0026amp;H app, an included remote, and optional wall thermostat compatibility (sold separately).\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"hvx-desc-card\"\u003e\n\u003ch2 class=\"hvx-section-title\"\u003eHighlights\u003c\/h2\u003e\n\u003cdiv class=\"hvx-badges\" role=\"list\"\u003e\n\u003cspan class=\"hvx-badge\" role=\"listitem\"\u003e12,000 BTU class\u003c\/span\u003e \u003cspan class=\"hvx-badge\" role=\"listitem\"\u003eR454B refrigerant\u003c\/span\u003e \u003cspan class=\"hvx-badge\" role=\"listitem\"\u003eUp to 24.0 SEER2\u003c\/span\u003e \u003cspan class=\"hvx-badge\" role=\"listitem\"\u003eHyper Heat to −22°F (Outdoor)\u003c\/span\u003e \u003cspan class=\"hvx-badge\" role=\"listitem\"\u003e208–230V, 1Ph, 60Hz\u003c\/span\u003e \u003cspan class=\"hvx-badge\" role=\"listitem\"\u003eSmart Kit included (App control)\u003c\/span\u003e \u003cspan class=\"hvx-badge\" role=\"listitem\"\u003eAuto-swing (horizontal louvers)\u003c\/span\u003e \u003cspan class=\"hvx-badge\" role=\"listitem\"\u003eTurbo Mode\u003c\/span\u003e\n\u003c\/div\u003e\n\u003cul style=\"margin: 12px 0 0; padding-left: 18px;\"\u003e\n\u003cli\u003e\n\u003cstrong\u003eGenius Core inverter performance:\u003c\/strong\u003e ultra-low compressor speed support for quiet, efficient operation.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e46°F freeze protection:\u003c\/strong\u003e added protection for cold conditions.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHigh-Frequency Racer Technology:\u003c\/strong\u003e rapid ramp to maximum speed on startup for quick comfort.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAdvanced refrigerant management:\u003c\/strong\u003e electronic expansion valve optimizes refrigerant flow control.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCleaner performance:\u003c\/strong\u003e intelligent dusting switch reverses the fan to help clear dust, sand, and debris from the coil.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eComfort automation:\u003c\/strong\u003e Follow Me, Timer On\/Off, and Sleep Mode for personalized scheduling.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cdiv class=\"hvx-kv\" role=\"list\" aria-label=\"At-a-glance\"\u003e\n\u003cdiv role=\"listitem\"\u003e\n\u003cstrong\u003eIndoor\u003c\/strong\u003eCH-R12MOLVWM-230VI\u003c\/div\u003e\n\u003cdiv role=\"listitem\"\u003e\n\u003cstrong\u003eOutdoor\u003c\/strong\u003eCH-RHP12-230VO\u003c\/div\u003e\n\u003cdiv role=\"listitem\"\u003e\n\u003cstrong\u003eLines\u003c\/strong\u003e1\/4\" liquid · 3\/8\" gas\u003c\/div\u003e\n\u003cdiv role=\"listitem\"\u003e\n\u003cstrong\u003eMax run\u003c\/strong\u003e82 ft\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"hvx-desc-card\"\u003e\n\u003ch2 class=\"hvx-section-title\"\u003eWhat’s Included\u003c\/h2\u003e\n\u003cul style=\"padding-left: 18px; margin: 8px 0;\"\u003e\n\u003cli\u003eIndoor unit: CH-R12MOLVWM-230VI\u003c\/li\u003e\n\u003cli\u003eOutdoor unit: CH-RHP12-230VO (Hyper Heating)\u003c\/li\u003e\n\u003cli\u003eRemote control\u003c\/li\u003e\n\u003cli\u003eSmart Kit (app connectivity)\u003c\/li\u003e\n\u003cli\u003eManufacturer documentation (see Downloads)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"hvx-desc-card\"\u003e\n\u003ch2 class=\"hvx-section-title\"\u003eIndoor Specs\u003c\/h2\u003e\n\u003cdiv class=\"hvx-table-wrap\"\u003e\n\u003ctable class=\"hvx-table\" aria-label=\"Indoor unit specifications\"\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eSpec\u003c\/th\u003e\n\u003cth\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIndoor Model\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCH-R12MOLVWM-230VI\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower Supply (Rated)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e208\/230 V, 1 Ø, 60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Capacity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e12,000 Btu\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMinimum Circuit Ampacity (MCA)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMax. fuse (A)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e15\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIndoor Air Flow (Turbo\/Hi\/Med\/Lo\/Si) (CFM)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e382.6 \/ 294.3 \/ 194.2 \/ 153.0 \/ N\/A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIndoor Noise Level (Turbo\/Hi\/Med\/Lo\/Si) dB(A)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eN\/A \/ 42 \/ 35.5 \/ 22.5 \/ 20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimension (W×D×H) (in)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e31.57 × 7.87 × 11.61\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePacking (W×D×H) (in)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e31.57 × 7.87 × 11.61\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNet\/Gross Weight (lb)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e18.96 \/ 24.25\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRoom Temperature (Cooling) (°F)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e60–90\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRoom Temperature (Heating) (°F)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e32–86\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRefrigerant piping Liquid\/Gas side (inch)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1\/4\" \/ 3\/8\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"hvx-desc-card\"\u003e\n\u003ch2 class=\"hvx-section-title\"\u003eOutdoor Specs\u003c\/h2\u003e\n\u003cdiv class=\"hvx-table-wrap\"\u003e\n\u003ctable class=\"hvx-table\" aria-label=\"Outdoor unit specifications\"\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eSpec\u003c\/th\u003e\n\u003cth\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCH-RHP12-230VO\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRefrigerant type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eR454B\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBTU Rated\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e12,000\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower source\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e208-230V, 1Ph, 60Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eVoltage range (V)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e187-253\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRefrigerant piping Liquid\/Gas side (inch)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1\/4\" \/ 3\/8\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMax. pipe length (ft)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e82\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMax height difference between Indoor and Outdoor unit\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e49.2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCooling capacity (Min\/Max) (BTU\/h)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e12,000 (3,800~14,600)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eHeating capacity (Min\/Max) (Btu\/h)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e12,000 (3,800~16,000)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOutdoor Noise Level\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e56\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOutdoor Air Flow\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1,470.6\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMinimum circuit ampacity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e15\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMax.fuse\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e15\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eHSPF2-5\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eHSPF2-4\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e10.5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCOP\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3.76\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAmbient temperature - Heating (F)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-22~75\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAmbient temperature - Cooling (F)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-22 ~ 122\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eUnit dimensions (W*H*D)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e31.69 x 12.99 x 21.81\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eUnit Net\/Gross weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e72.75\/78.70\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePacking dimensions (WxDxH)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e36.02 x 14.57 x 24.21\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRefrigerant precharge\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e25\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAdditional Refrigerant Charge 1\/4 liquid line\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.16\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"hvx-desc-card\"\u003e\n\u003ch2 class=\"hvx-section-title\"\u003eDocuments \u0026amp; Downloads\u003c\/h2\u003e\n\u003cul style=\"padding-left: 18px; margin: 8px 0;\"\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/media.cooperandhunter.us\/4729\/CH-RES12-230VO_CH-R12MOLVWM-230VI.pdf\" target=\"_blank\" rel=\"noopener\"\u003eSubmittal (PDF): CH-R12MOLVWM-230VI (Link 1)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca class=\"hvx-link\" href=\"https:\/\/drive.google.com\/file\/d\/11uCRDvBhIcMpwvzipwSXF-SzHNnvy1ty\/view?usp=drive_link\" rel=\"noopener\" target=\"_blank\"\u003eSubmittal (PDF): CH-R12MOLVWM-230VI (Link 2)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca class=\"hvx-link\" href=\"https:\/\/media.cooperandhunter.us\/4170\/CH-RHP12-230VO-%2B-CH-RH12MASTWM-230VI.pdf\" rel=\"noopener\" target=\"_blank\"\u003eSubmittal (PDF): CH-RHP12-230VO + CH-RH12MASTWM-230VI\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca class=\"hvx-link\" href=\"https:\/\/media.cooperandhunter.us\/4203\/CH-RHP12-230VO-%2B-CH-RS06-12MDT--MS.pdf\" rel=\"noopener\" target=\"_blank\"\u003eSubmittal (PDF): CH-RHP12-230VO + CH-RS06-12MDT--MS\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca class=\"hvx-link\" href=\"https:\/\/media.cooperandhunter.us\/4682\/CH-RHP09-230VO_CH-RH09MCT.pdf\" rel=\"noopener\" target=\"_blank\"\u003eSubmittal (PDF): CH-RHP09-230VO + CH-RH09MCT\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca class=\"hvx-link\" href=\"https:\/\/media.cooperandhunter.us\/4683\/CH-RHP09-230VO_CH-RSH09MCT.pdf\" rel=\"noopener\" target=\"_blank\"\u003eSubmittal (PDF): CH-RHP09-230VO + CH-RSH09MCT\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca class=\"hvx-link\" href=\"https:\/\/media.cooperandhunter.us\/4118\/Installation-Manual-R454B-Outdoor-units--.pdf\" rel=\"noopener\" target=\"_blank\"\u003eInstallation Manual (PDF): R454B Outdoor Units\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca class=\"hvx-link\" href=\"https:\/\/media.cooperandhunter.us\/4200\/SlimDuct-Leaflet-R454B.pdf\" rel=\"noopener\" target=\"_blank\"\u003eLeaflet (PDF): SlimDuct — R454B\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca class=\"hvx-link\" href=\"https:\/\/cooperandhunter.us\/product\/ch-rhp12-230vo\" rel=\"noopener\" target=\"_blank\"\u003eManufacturer Page: CH-RHP12-230VO\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca class=\"hvx-link\" href=\"https:\/\/www.ahridirectory.org\" rel=\"noopener\" target=\"_blank\"\u003eAHRI Directory Listing: 207742320\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"hvx-desc-card\"\u003e\n\u003ch2 class=\"hvx-section-title\"\u003eImportant\u003c\/h2\u003e\n\u003cp style=\"margin: 0; font-size: 14px; color: var(--hvx-slate);\"\u003eProfessional installation is recommended. Confirm electrical requirements, line sizes, maximum line length, and ambient operating limits before installation.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"hvx-desc-card\"\u003e\n\u003ch2 class=\"hvx-section-title\"\u003eFAQs\u003c\/h2\u003e\n\u003cdetails class=\"hvx-faq\" open=\"\"\u003e\n\u003csummary\u003eIs this system Hyper Heat?\u003c\/summary\u003e\n\u003cdiv style=\"margin-top: 8px;\"\u003eYes—Hyper Heating operation is rated down to −22°F.\u003c\/div\u003e\n\u003c\/details\u003e\n\u003cdetails class=\"hvx-faq\" open=\"\"\u003e\n\u003csummary\u003eWhat line sizes does this system use?\u003c\/summary\u003e\n\u003cdiv style=\"margin-top: 8px;\"\u003e1\/4\" liquid and 3\/8\" gas.\u003c\/div\u003e\n\u003c\/details\u003e\n\u003cdetails class=\"hvx-faq\" open=\"\"\u003e\n\u003csummary\u003eDoes it include smart control?\u003c\/summary\u003e\n\u003cdiv style=\"margin-top: 8px;\"\u003eYes—Smart Kit is included for C\u0026amp;H app control, and a remote is included.\u003c\/div\u003e\n\u003c\/details\u003e\n\u003cdetails class=\"hvx-faq\" open=\"\"\u003e\n\u003csummary\u003eWhat comfort modes are included?\u003c\/summary\u003e\n\u003cdiv style=\"margin-top: 8px;\"\u003eTurbo Mode, Follow Me, Timer On\/Off, Sleep Mode, and 46°F Freeze Protection.\u003c\/div\u003e\n\u003c\/details\u003e\n\u003cdetails class=\"hvx-faq\" open=\"\"\u003e\n\u003csummary\u003eIs a wall thermostat supported?\u003c\/summary\u003e\n\u003cdiv style=\"margin-top: 8px;\"\u003eYes—wall thermostat compatibility is available (thermostat sold separately).\u003c\/div\u003e\n\u003c\/details\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e","brand":"Cooper\u0026Hunter","offers":[{"title":"No installation","offer_id":42673007689771,"sku":"CH-R12MOLVWM-230VI + CH-RHP12-230VO","price":1546.0,"currency_code":"USD","in_stock":true},{"title":"16FT","offer_id":42673007722539,"sku":"CH-R12MOLVWM-230VI + CH-RHP12-230VO","price":1728.0,"currency_code":"USD","in_stock":true},{"title":"25FT","offer_id":42673007755307,"sku":"CH-R12MOLVWM-230VI + CH-RHP12-230VO","price":1774.0,"currency_code":"USD","in_stock":true},{"title":"50FT","offer_id":42673007788075,"sku":"CH-R12MOLVWM-230VI + CH-RHP12-230VO","price":1994.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0625\/5647\/1339\/files\/1_91be9011-04fa-4032-8e15-d1ef63412eb0.png?v=1768107224"},{"product_id":"cooper-hunter-18-000-btu-olivia-hyper-single-zone-wall-mount-minisplit-heat-pump-system-r454b-230v","title":"Cooper\u0026Hunter 18,000 BTU Olivia Hyper Single Zone Wall Mount Minisplit Heat Pump System R454B 230V","description":"\u003cstyle\u003e\n  :root{\n    --hvx-golden:#FAA819;\n    --hvx-slate:#262626;\n    --hvx-ivory:#F4F1E6;\n    --hvx-border:#e2e0d5;\n    --hvx-card-bg:#ffffff;\n  }\n\n  .hvx-desc{\n    font-family:\"Articulat CF\",system-ui,-apple-system,BlinkMacSystemFont,\"Segoe UI\",sans-serif;\n    color:var(--hvx-slate);\n    line-height:1.6;\n    background:var(--hvx-ivory);\n    padding:18px 18px 20px;\n    border-radius:16px;\n  }\n\n  .hvx-desc-header{\n    border-radius:14px;\n    padding:14px 16px;\n    background:linear-gradient(120deg,var(--hvx-golden),var(--hvx-slate));\n    color:#fff;\n    margin:0 0 16px;\n    box-shadow:0 10px 24px rgba(0,0,0,.22);\n    display:flex;\n    align-items:flex-start;\n    gap:12px;\n    flex-wrap:wrap;\n  }\n\n  .hvx-header-text{display:flex;flex-direction:column;gap:6px;min-width:260px}\n  .hvx-eyebrow{\n    font-size:11px;\n    letter-spacing:.14em;\n    text-transform:uppercase;\n    opacity:.9;\n  }\n  .hvx-title{\n    margin:0;\n    font-family:\"Anton\",\"Impact\",system-ui,-apple-system,BlinkMacSystemFont,\"Segoe UI\",sans-serif;\n    font-size:22px;\n    line-height:1.15;\n  }\n  .hvx-subtitle{margin:0;font-size:14px;opacity:.95}\n\n  .hvx-desc-card{\n    border:1px solid var(--hvx-border);\n    border-radius:14px;\n    background:var(--hvx-card-bg);\n    padding:16px 18px 18px;\n    box-shadow:0 4px 12px rgba(0,0,0,.06);\n    margin:14px 0;\n  }\n\n  .hvx-section-title{\n    margin:0 0 10px;\n    font-family:\"Anton\",\"Impact\",system-ui,-apple-system,BlinkMacSystemFont,\"Segoe UI\",sans-serif;\n    font-size:17px;\n    letter-spacing:.08em;\n    text-transform:uppercase;\n    color:var(--hvx-slate);\n    display:inline-flex;\n    align-items:center;\n    gap:8px;\n  }\n  .hvx-section-title::after{\n    content:\"\";\n    flex:1;\n    height:2px;\n    border-radius:999px;\n    background:linear-gradient(90deg,var(--hvx-golden),transparent);\n    opacity:.9;\n  }\n\n  .hvx-cta{display:flex;flex-wrap:wrap;gap:10px;margin:10px 0 0}\n  .hvx-cta a{\n    display:inline-flex;\n    align-items:center;\n    gap:8px;\n    padding:10px 14px;\n    border-radius:12px;\n    border:1px solid var(--hvx-border);\n    background:#fff;\n    text-decoration:none;\n    color:var(--hvx-slate);\n    font-size:14px;\n    font-weight:700;\n  }\n  .hvx-cta a.primary{\n    background:var(--hvx-slate);\n    color:#fff;\n    border-color:transparent;\n  }\n\n  .hvx-badges{display:flex;flex-wrap:wrap;gap:8px;margin:10px 0 0}\n  .hvx-badge{\n    font-size:12px;\n    border:1px solid var(--hvx-border);\n    border-radius:999px;\n    padding:6px 10px;\n    background:#fff;\n    white-space:nowrap;\n  }\n\n  .hvx-kv{\n    display:grid;\n    grid-template-columns:repeat(4,minmax(160px,1fr));\n    gap:10px;\n    margin-top:10px;\n  }\n  .hvx-kv \u003e div{\n    border:1px solid var(--hvx-border);\n    background:#fff;\n    border-radius:12px;\n    padding:10px 12px;\n    text-align:center;\n  }\n  .hvx-kv strong{display:block}\n\n  .hvx-table{\n    width:100%;\n    border-collapse:collapse;\n    min-width:520px;\n    background:#fff;\n    border:1px solid var(--hvx-border);\n    border-radius:12px;\n    overflow:hidden;\n  }\n  .hvx-table th,.hvx-table td{\n    border-bottom:1px solid var(--hvx-border);\n    padding:10px 12px;\n    vertical-align:top;\n    font-size:14px;\n  }\n  .hvx-table th{ text-align:left; font-weight:800; background:#fff; }\n  .hvx-table tr:nth-child(even) td{ background:#fbfaf6; }\n  .hvx-table tr:last-child td{ border-bottom:none; }\n  .hvx-table-wrap{ overflow:auto; border-radius:12px; }\n\n  .hvx-link{color:var(--hvx-slate); text-decoration:underline; text-underline-offset:2px}\n  .hvx-link:hover{opacity:.85}\n\n  details.hvx-faq{\n    border:1px solid var(--hvx-border);\n    background:#fff;\n    border-radius:12px;\n    padding:10px 12px;\n    margin:8px 0;\n  }\n  details.hvx-faq summary{cursor:pointer;font-weight:800}\n\n  @media(max-width:980px){\n    .hvx-kv{grid-template-columns:repeat(2,minmax(160px,1fr))}\n  }\n  @media(max-width:768px){\n    .hvx-desc{padding:14px 12px 16px;border-radius:12px}\n    .hvx-desc-header{padding:12px;border-radius:12px}\n    .hvx-title{font-size:19px}\n    .hvx-desc-card{padding:14px;margin:10px 0}\n  }\n\u003c\/style\u003e\n\u003cdiv class=\"hvx-desc\"\u003e\n\u003cdiv class=\"hvx-desc-header\"\u003e\n\u003cdiv class=\"hvx-header-text\"\u003e\n\u003cdiv class=\"hvx-eyebrow\"\u003eCooper\u0026amp;Hunter Olivia • R454B • Hyper Heat\u003c\/div\u003e\n\u003ch1 class=\"hvx-title\"\u003eCooper\u0026amp;Hunter 18,000 BTU Olivia Single Zone Wall Mount Mini Split Heat Pump System R454B 230V\u003c\/h1\u003e\n\u003cp class=\"hvx-subtitle\"\u003e\u003cstrong\u003eSKU:\u003c\/strong\u003e CH-R18MOLVWM-230VI + CH-RHP18-230VO\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv aria-label=\"Contact options\" class=\"hvx-cta\"\u003e\n\u003ca title=\"Contact Us\" rel=\"noopener\" href=\"https:\/\/hvacsupplies.com\/pages\/contact\" class=\"primary\" target=\"_blank\"\u003e CLICK HERE TO CONTACT US FOR CUSTOM QUOTES AND QUESTIONS \u003c\/a\u003e \u003ca title=\"Call Us Now!\" href=\"tel:+18005438933\"\u003eCLICK TO CALL US 800-543-8933 FOR ANY QUESTIONS\u003c\/a\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"hvx-desc-card\"\u003e\n\u003ch2 class=\"hvx-section-title\"\u003eOverview\u003c\/h2\u003e\n\u003cp style=\"margin: 0;\"\u003eEnhance your home's climate control with the Cooper\u0026amp;Hunter \u003cstrong\u003e18K BTU Olivia\u003c\/strong\u003e wall-mounted mini split utilizing \u003cstrong\u003eR454B\u003c\/strong\u003e refrigerant for improved efficiency and a lower environmental impact. With \u003cstrong\u003eup to 21.7 SEER2\u003c\/strong\u003e efficiency, this 230V system delivers modern comfort features and strong performance for medium to large spaces.\u003c\/p\u003e\n\u003cp style=\"margin: 10px 0 0;\"\u003eAuto-swing horizontal louvers help distribute air evenly, while inverter technology supports quiet, efficient operation. Paired with a \u003cstrong\u003eHyper Heating\u003c\/strong\u003e outdoor unit designed for cold climates, this system provides reliable heating performance down to \u003cstrong\u003e−22°F\u003c\/strong\u003e. Controls include Smart Kit app connectivity through the C\u0026amp;H app, an included remote, and optional wall thermostat compatibility (sold separately).\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"hvx-desc-card\"\u003e\n\u003ch2 class=\"hvx-section-title\"\u003eHighlights\u003c\/h2\u003e\n\u003cdiv role=\"list\" class=\"hvx-badges\"\u003e\n\u003cspan role=\"listitem\" class=\"hvx-badge\"\u003e18,000 BTU class\u003c\/span\u003e \u003cspan role=\"listitem\" class=\"hvx-badge\"\u003eR454B refrigerant\u003c\/span\u003e \u003cspan role=\"listitem\" class=\"hvx-badge\"\u003eUp to 21.7 SEER2\u003c\/span\u003e \u003cspan role=\"listitem\" class=\"hvx-badge\"\u003eHyper Heat to −22°F (Outdoor)\u003c\/span\u003e \u003cspan role=\"listitem\" class=\"hvx-badge\"\u003e208–230V, 1Ph, 60Hz\u003c\/span\u003e \u003cspan role=\"listitem\" class=\"hvx-badge\"\u003eSmart Kit included (App control)\u003c\/span\u003e \u003cspan role=\"listitem\" class=\"hvx-badge\"\u003eAuto-swing (horizontal louvers)\u003c\/span\u003e \u003cspan role=\"listitem\" class=\"hvx-badge\"\u003eTU1 copper tubes\u003c\/span\u003e\n\u003c\/div\u003e\n\u003cul style=\"margin: 12px 0 0; padding-left: 18px;\"\u003e\n\u003cli\u003e\n\u003cstrong\u003ePowerful airflow:\u003c\/strong\u003e up to 759.3 CFM (Turbo) for strong room circulation.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e46°F freeze protection:\u003c\/strong\u003e added protection for cold conditions.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHigh-Frequency Racer Technology:\u003c\/strong\u003e rapid ramp to maximum speed on startup for quick comfort.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAdvanced refrigerant management:\u003c\/strong\u003e electronic expansion valve optimizes refrigerant flow control.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCleaner performance:\u003c\/strong\u003e intelligent dusting switch reverses the fan to help clear dust, sand, and debris from the coil.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eComfort automation:\u003c\/strong\u003e Follow Me, Timer On\/Off, Sleep Mode, and Turbo Mode.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cdiv aria-label=\"At-a-glance\" role=\"list\" class=\"hvx-kv\"\u003e\n\u003cdiv role=\"listitem\"\u003e\n\u003cstrong\u003eIndoor\u003c\/strong\u003eCH-R18MOLVWM-230VI\u003c\/div\u003e\n\u003cdiv role=\"listitem\"\u003e\n\u003cstrong\u003eOutdoor\u003c\/strong\u003eCH-RHP18-230VO\u003c\/div\u003e\n\u003cdiv role=\"listitem\"\u003e\n\u003cstrong\u003eLines\u003c\/strong\u003e1\/4\" liquid · 1\/2\" gas\u003c\/div\u003e\n\u003cdiv role=\"listitem\"\u003e\n\u003cstrong\u003eMax run\u003c\/strong\u003e98.4 ft\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"hvx-desc-card\"\u003e\n\u003ch2 class=\"hvx-section-title\"\u003eWhat’s Included\u003c\/h2\u003e\n\u003cul style=\"padding-left: 18px; margin: 8px 0;\"\u003e\n\u003cli\u003eIndoor unit: CH-R18MOLVWM-230VI\u003c\/li\u003e\n\u003cli\u003eOutdoor unit: CH-RHP18-230VO (Hyper Heating)\u003c\/li\u003e\n\u003cli\u003eRemote control\u003c\/li\u003e\n\u003cli\u003eSmart Kit (app connectivity)\u003c\/li\u003e\n\u003cli\u003eManufacturer documentation (see Downloads)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"hvx-desc-card\"\u003e\n\u003ch2 class=\"hvx-section-title\"\u003eIndoor Specs\u003c\/h2\u003e\n\u003cdiv class=\"hvx-table-wrap\"\u003e\n\u003ctable aria-label=\"Indoor unit specifications\" class=\"hvx-table\"\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eSpec\u003c\/th\u003e\n\u003cth\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIndoor Model\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCH-R18MOLVWM-230VI\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower Supply (Rated)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e208\/230 V, 1 Ø, 60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Capacity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e18,000 Btu\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMinimum Circuit Ampacity (MCA)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMax. fuse (A)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e15\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIndoor Air Flow (Turbo\/Hi\/Med\/Lo\/Si) (CFM)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e759.3 \/ 500.3 \/ 441.4 \/ 370.8 \/ N\/A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIndoor Noise Level (Turbo\/Hi\/Med\/Lo\/Si) dB(A)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e54.5 \/ 45 \/ 40 \/ 24.5 \/ 20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimension (W×D×H) (in)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e42.60 × 9.21 × 13.27\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePacking (W×D×H) (in)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e45.47 × 12.40 × 16.34\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNet\/Gross Weight (lb)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e30.42 \/ 39.68\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRoom Temperature (Cooling) (°F)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e60–90\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRoom Temperature (Heating) (°F)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e32–86\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRefrigerant piping Liquid\/Gas side (inch)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1\/4\" \/ 1\/2\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"hvx-desc-card\"\u003e\n\u003ch2 class=\"hvx-section-title\"\u003eOutdoor Specs\u003c\/h2\u003e\n\u003cdiv class=\"hvx-table-wrap\"\u003e\n\u003ctable aria-label=\"Outdoor unit specifications\" class=\"hvx-table\"\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eSpec\u003c\/th\u003e\n\u003cth\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCH-RHP18-230VO\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSystem type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSingle-zone unit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRefrigerant type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eR454B\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBTU Rated\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e18,000\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower source\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e208-230V, 1Ph, 60Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eVoltage range (V)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e187-253\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRefrigerant piping Liquid\/Gas side (inch)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1\/4\" \/ 1\/2\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMax. pipe length (ft)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e98.4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMax height difference between Indoor and Outdoor unit\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e65.6\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCooling capacity (Min\/Max) (BTU\/h)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e17,000 (6,500~18,800)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eHeating capacity (Min\/Max) (Btu\/h)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e19,000 (8,900~22,000)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSEER2\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e18\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEER2\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e12\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eHSPF2-5\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e9\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eHSPF2-4\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e10.5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCOP\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3.37\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDehumidification value (pnt\/day)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3.53\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOutdoor Noise Level\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e59\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOutdoor Air Flow\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1,765.8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMinimum circuit ampacity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e19\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMax.fuse\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAmbient temperature - Heating (F)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-22~75\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAmbient temperature - Cooling (F)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-22 ~ 122\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eUnit dimensions (W*H*D)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e35.04 x 13.46 x 26.50\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eUnit Net\/Gross weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e99.87\/107.80\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePacking dimensions (WxDxH)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e39.17 x 15.67 x 29.13\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRefrigerant precharge\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e25\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAdditional Refrigerant Charge 1\/4 liquid line\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.16\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"hvx-desc-card\"\u003e\n\u003ch2 class=\"hvx-section-title\"\u003eDocuments \u0026amp; Downloads\u003c\/h2\u003e\n\u003cul style=\"padding-left: 18px; margin: 8px 0;\"\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/media.cooperandhunter.us\/4770\/CH-RHP18-230VO_CH-R18MOLVWM-230VI.pdf\" target=\"_blank\" rel=\"noopener\"\u003eSubmittal (PDF): CH-R18MOLVWM-230VI (Link 1)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca rel=\"noopener\" href=\"https:\/\/drive.google.com\/file\/d\/11uCRDvBhIcMpwvzipwSXF-SzHNnvy1ty\/view?usp=drive_link\" class=\"hvx-link\" target=\"_blank\"\u003eSubmittal (PDF): CH-R18MOLVWM-230VI (Link 2)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca rel=\"noopener\" href=\"https:\/\/media.cooperandhunter.us\/4158\/CH-RHP18-230VO-%2B-CH-PRO18MASTWM-230VI.pdf\" class=\"hvx-link\" target=\"_blank\"\u003eSubmittal (PDF): CH-RHP18-230VO + CH-PRO18MASTWM-230VI\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca rel=\"noopener\" href=\"https:\/\/media.cooperandhunter.us\/4172\/CH-RHP18-230VO-%2B-CH-RH18MASTWM-230VI.pdf\" class=\"hvx-link\" target=\"_blank\"\u003eSubmittal (PDF): CH-RHP18-230VO + CH-RH18MASTWM-230VI\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca rel=\"noopener\" href=\"https:\/\/media.cooperandhunter.us\/4204\/CH-RHP18-230VO-%2B-CH-RS18MDT-MS.pdf\" class=\"hvx-link\" target=\"_blank\"\u003eSubmittal (PDF): CH-RHP18-230VO + CH-RS18MDT-MS\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca rel=\"noopener\" href=\"https:\/\/media.cooperandhunter.us\/4251\/CH-RHP18-230VO-%2B-CH-RS18MAHU.pdf\" class=\"hvx-link\" target=\"_blank\"\u003eSubmittal (PDF): CH-RHP18-230VO + CH-RS18MAHU\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca rel=\"noopener\" href=\"https:\/\/media.cooperandhunter.us\/4630\/CH-RHP18-230VO_CH-RSH18MFC.pdf\" class=\"hvx-link\" target=\"_blank\"\u003eSubmittal (PDF): CH-RHP18-230VO + CH-RSH18MFC\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca rel=\"noopener\" href=\"https:\/\/media.cooperandhunter.us\/4686\/CH-RHP18-230VO_CH-RH18MCT.pdf\" class=\"hvx-link\" target=\"_blank\"\u003eSubmittal (PDF): CH-RHP18-230VO + CH-RH18MCT\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca rel=\"noopener\" href=\"https:\/\/media.cooperandhunter.us\/4687\/CH-RHP18-230VO_CH-RSH18MCT.pdf\" class=\"hvx-link\" target=\"_blank\"\u003eSubmittal (PDF): CH-RHP18-230VO + CH-RSH18MCT\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca rel=\"noopener\" href=\"https:\/\/media.cooperandhunter.us\/4118\/Installation-Manual-R454B-Outdoor-units--.pdf\" class=\"hvx-link\" target=\"_blank\"\u003eInstallation Manual (PDF): R454B Outdoor Units\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca rel=\"noopener\" href=\"https:\/\/media.cooperandhunter.us\/4200\/SlimDuct-Leaflet-R454B.pdf\" class=\"hvx-link\" target=\"_blank\"\u003eLeaflet (PDF): SlimDuct — R454B\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca rel=\"noopener\" href=\"https:\/\/cooperandhunter.us\/product\/ch-rhp18-230vo\" class=\"hvx-link\" target=\"_blank\"\u003eManufacturer Page: CH-RHP18-230VO\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca rel=\"noopener\" href=\"https:\/\/www.ahridirectory.org\/NewSearch?programId=41\u0026amp;searchTypeId=3\u0026amp;productTypeId=4\" class=\"hvx-link\" target=\"_blank\"\u003eAHRI Directory Listing: 207742320\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"hvx-desc-card\"\u003e\n\u003ch2 class=\"hvx-section-title\"\u003eImportant\u003c\/h2\u003e\n\u003cp style=\"margin: 0; font-size: 14px; color: var(--hvx-slate);\"\u003eProfessional installation is recommended. Confirm electrical requirements, line sizes, maximum line length, and ambient operating limits before installation.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"hvx-desc-card\"\u003e\n\u003ch2 class=\"hvx-section-title\"\u003eFAQs\u003c\/h2\u003e\n\u003cdetails open=\"\" class=\"hvx-faq\"\u003e\n\u003csummary\u003eIs this system Hyper Heat?\u003c\/summary\u003e\n\u003cdiv style=\"margin-top: 8px;\"\u003eYes—Hyper Heating operation is rated down to −22°F.\u003c\/div\u003e\n\u003c\/details\u003e\n\u003cdetails open=\"\" class=\"hvx-faq\"\u003e\n\u003csummary\u003eWhat line sizes does this system use?\u003c\/summary\u003e\n\u003cdiv style=\"margin-top: 8px;\"\u003e1\/4\" liquid and 1\/2\" gas.\u003c\/div\u003e\n\u003c\/details\u003e\n\u003cdetails open=\"\" class=\"hvx-faq\"\u003e\n\u003csummary\u003eDoes it include smart control?\u003c\/summary\u003e\n\u003cdiv style=\"margin-top: 8px;\"\u003eYes—Smart Kit is included for C\u0026amp;H app control, and a remote is included.\u003c\/div\u003e\n\u003c\/details\u003e\n\u003cdetails open=\"\" class=\"hvx-faq\"\u003e\n\u003csummary\u003eWhat is the maximum line set length?\u003c\/summary\u003e\n\u003cdiv style=\"margin-top: 8px;\"\u003eUp to 98.4 ft (maximum pipe length).\u003c\/div\u003e\n\u003c\/details\u003e\n\u003cdetails open=\"\" class=\"hvx-faq\"\u003e\n\u003csummary\u003eIs a wall thermostat supported?\u003c\/summary\u003e\n\u003cdiv style=\"margin-top: 8px;\"\u003eYes—wall thermostat compatibility is available (thermostat sold separately).\u003c\/div\u003e\n\u003c\/details\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e","brand":"Cooper\u0026Hunter","offers":[{"title":"No installation","offer_id":42673009819691,"sku":"CH-R18MOLVWM-230VI + CH-RHP18-230VO","price":2145.0,"currency_code":"USD","in_stock":true},{"title":"16FT","offer_id":42673009852459,"sku":"CH-R18MOLVWM-230VI + CH-RHP18-230VO","price":2354.0,"currency_code":"USD","in_stock":true},{"title":"25FT","offer_id":42673009885227,"sku":"CH-R18MOLVWM-230VI + CH-RHP18-230VO","price":2399.0,"currency_code":"USD","in_stock":true},{"title":"50FT","offer_id":42673009917995,"sku":"CH-R18MOLVWM-230VI + CH-RHP18-230VO","price":2602.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0625\/5647\/1339\/files\/1_91be9011-04fa-4032-8e15-d1ef63412eb0.png?v=1768107224"},{"product_id":"cooper-hunter-24-000-btu-olivia-hyper-single-zone-wall-mount-minisplit-heat-pump-system-r454b-230v","title":"Cooper\u0026Hunter 24,000 BTU Olivia Hyper Single Zone Wall Mount Minisplit Heat Pump System R454B 230V","description":"\u003cstyle\u003e\n  :root{\n    --hvx-golden:#FAA819;\n    --hvx-slate:#262626;\n    --hvx-ivory:#F4F1E6;\n    --hvx-border:#e2e0d5;\n    --hvx-card-bg:#ffffff;\n  }\n\n  .hvx-desc{\n    font-family:\"Articulat CF\",system-ui,-apple-system,BlinkMacSystemFont,\"Segoe UI\",sans-serif;\n    color:var(--hvx-slate);\n    line-height:1.6;\n    background:var(--hvx-ivory);\n    padding:18px 18px 20px;\n    border-radius:16px;\n  }\n\n  .hvx-desc-header{\n    border-radius:14px;\n    padding:14px 16px;\n    background:linear-gradient(120deg,var(--hvx-golden),var(--hvx-slate));\n    color:#fff;\n    margin:0 0 16px;\n    box-shadow:0 10px 24px rgba(0,0,0,.22);\n    display:flex;\n    align-items:flex-start;\n    gap:12px;\n    flex-wrap:wrap;\n  }\n\n  .hvx-header-text{display:flex;flex-direction:column;gap:6px;min-width:260px}\n  .hvx-eyebrow{\n    font-size:11px;\n    letter-spacing:.14em;\n    text-transform:uppercase;\n    opacity:.9;\n  }\n  .hvx-title{\n    margin:0;\n    font-family:\"Anton\",\"Impact\",system-ui,-apple-system,BlinkMacSystemFont,\"Segoe UI\",sans-serif;\n    font-size:22px;\n    line-height:1.15;\n  }\n  .hvx-subtitle{margin:0;font-size:14px;opacity:.95}\n\n  .hvx-desc-card{\n    border:1px solid var(--hvx-border);\n    border-radius:14px;\n    background:var(--hvx-card-bg);\n    padding:16px 18px 18px;\n    box-shadow:0 4px 12px rgba(0,0,0,.06);\n    margin:14px 0;\n  }\n\n  .hvx-section-title{\n    margin:0 0 10px;\n    font-family:\"Anton\",\"Impact\",system-ui,-apple-system,BlinkMacSystemFont,\"Segoe UI\",sans-serif;\n    font-size:17px;\n    letter-spacing:.08em;\n    text-transform:uppercase;\n    color:var(--hvx-slate);\n    display:inline-flex;\n    align-items:center;\n    gap:8px;\n  }\n  .hvx-section-title::after{\n    content:\"\";\n    flex:1;\n    height:2px;\n    border-radius:999px;\n    background:linear-gradient(90deg,var(--hvx-golden),transparent);\n    opacity:.9;\n  }\n\n  .hvx-cta{display:flex;flex-wrap:wrap;gap:10px;margin:10px 0 0}\n  .hvx-cta a{\n    display:inline-flex;\n    align-items:center;\n    gap:8px;\n    padding:10px 14px;\n    border-radius:12px;\n    border:1px solid var(--hvx-border);\n    background:#fff;\n    text-decoration:none;\n    color:var(--hvx-slate);\n    font-size:14px;\n    font-weight:700;\n  }\n  .hvx-cta a.primary{\n    background:var(--hvx-slate);\n    color:#fff;\n    border-color:transparent;\n  }\n\n  .hvx-badges{display:flex;flex-wrap:wrap;gap:8px;margin:10px 0 0}\n  .hvx-badge{\n    font-size:12px;\n    border:1px solid var(--hvx-border);\n    border-radius:999px;\n    padding:6px 10px;\n    background:#fff;\n    white-space:nowrap;\n  }\n\n  .hvx-kv{\n    display:grid;\n    grid-template-columns:repeat(4,minmax(160px,1fr));\n    gap:10px;\n    margin-top:10px;\n  }\n  .hvx-kv \u003e div{\n    border:1px solid var(--hvx-border);\n    background:#fff;\n    border-radius:12px;\n    padding:10px 12px;\n    text-align:center;\n  }\n  .hvx-kv strong{display:block}\n\n  .hvx-table{\n    width:100%;\n    border-collapse:collapse;\n    min-width:520px;\n    background:#fff;\n    border:1px solid var(--hvx-border);\n    border-radius:12px;\n    overflow:hidden;\n  }\n  .hvx-table th,.hvx-table td{\n    border-bottom:1px solid var(--hvx-border);\n    padding:10px 12px;\n    vertical-align:top;\n    font-size:14px;\n  }\n  .hvx-table th{ text-align:left; font-weight:800; background:#fff; }\n  .hvx-table tr:nth-child(even) td{ background:#fbfaf6; }\n  .hvx-table tr:last-child td{ border-bottom:none; }\n  .hvx-table-wrap{ overflow:auto; border-radius:12px; }\n\n  .hvx-link{color:var(--hvx-slate); text-decoration:underline; text-underline-offset:2px}\n  .hvx-link:hover{opacity:.85}\n\n  details.hvx-faq{\n    border:1px solid var(--hvx-border);\n    background:#fff;\n    border-radius:12px;\n    padding:10px 12px;\n    margin:8px 0;\n  }\n  details.hvx-faq summary{cursor:pointer;font-weight:800}\n\n  @media(max-width:980px){\n    .hvx-kv{grid-template-columns:repeat(2,minmax(160px,1fr))}\n  }\n  @media(max-width:768px){\n    .hvx-desc{padding:14px 12px 16px;border-radius:12px}\n    .hvx-desc-header{padding:12px;border-radius:12px}\n    .hvx-title{font-size:19px}\n    .hvx-desc-card{padding:14px;margin:10px 0}\n  }\n\u003c\/style\u003e\n\u003cdiv class=\"hvx-desc\"\u003e\n\u003cdiv class=\"hvx-desc-header\"\u003e\n\u003cdiv class=\"hvx-header-text\"\u003e\n\u003cdiv class=\"hvx-eyebrow\"\u003eCooper\u0026amp;Hunter Olivia • R454B • Hyper Heat\u003c\/div\u003e\n\u003ch1 class=\"hvx-title\"\u003eCooper\u0026amp;Hunter 24,000 BTU Olivia Single Zone Wall Mount Mini Split Heat Pump System R454B 230V\u003c\/h1\u003e\n\u003cp class=\"hvx-subtitle\"\u003e\u003cstrong\u003eSKU:\u003c\/strong\u003e CH-R24MOLVWM-230VI + CH-RHP24-230VO\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv aria-label=\"Contact options\" class=\"hvx-cta\"\u003e\n\u003ca title=\"Contact Us\" rel=\"noopener\" href=\"https:\/\/hvacsupplies.com\/pages\/contact\" class=\"primary\" target=\"_blank\"\u003e CLICK HERE TO CONTACT US FOR CUSTOM QUOTES AND QUESTIONS \u003c\/a\u003e \u003ca title=\"Call Us Now!\" href=\"tel:+18005438933\"\u003eCLICK TO CALL US 800-543-8933 FOR ANY QUESTIONS\u003c\/a\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"hvx-desc-card\"\u003e\n\u003ch2 class=\"hvx-section-title\"\u003eOverview\u003c\/h2\u003e\n\u003cp style=\"margin: 0;\"\u003eEnhance your home's climate control with the Cooper\u0026amp;Hunter \u003cstrong\u003e24K BTU Olivia\u003c\/strong\u003e wall-mounted mini split utilizing \u003cstrong\u003eR454B\u003c\/strong\u003e refrigerant for improved efficiency and a lower environmental impact. With \u003cstrong\u003eup to 22.3 SEER2\u003c\/strong\u003e efficiency, this 230V system delivers powerful, modern comfort for larger spaces.\u003c\/p\u003e\n\u003cp style=\"margin: 10px 0 0;\"\u003eAuto-swing horizontal louvers help distribute air evenly, while inverter technology matches output to demand for efficient temperature control. Paired with a \u003cstrong\u003eHyper Heating\u003c\/strong\u003e outdoor unit, this system provides reliable heating performance down to \u003cstrong\u003e−22°F\u003c\/strong\u003e. Controls include Smart Kit app connectivity through the C\u0026amp;H app, an included remote, and optional wall thermostat compatibility (sold separately).\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"hvx-desc-card\"\u003e\n\u003ch2 class=\"hvx-section-title\"\u003eHighlights\u003c\/h2\u003e\n\u003cdiv role=\"list\" class=\"hvx-badges\"\u003e\n\u003cspan role=\"listitem\" class=\"hvx-badge\"\u003e24,000 BTU class\u003c\/span\u003e \u003cspan role=\"listitem\" class=\"hvx-badge\"\u003eR454B refrigerant\u003c\/span\u003e \u003cspan role=\"listitem\" class=\"hvx-badge\"\u003eUp to 22.3 SEER2\u003c\/span\u003e \u003cspan role=\"listitem\" class=\"hvx-badge\"\u003eHyper Heat to −22°F (Outdoor)\u003c\/span\u003e \u003cspan role=\"listitem\" class=\"hvx-badge\"\u003e208–230V, 1Ph, 60Hz\u003c\/span\u003e \u003cspan role=\"listitem\" class=\"hvx-badge\"\u003eSmart Kit included (App control)\u003c\/span\u003e \u003cspan role=\"listitem\" class=\"hvx-badge\"\u003eAuto-swing (horizontal louvers)\u003c\/span\u003e \u003cspan role=\"listitem\" class=\"hvx-badge\"\u003eTU1 copper tubes\u003c\/span\u003e\n\u003c\/div\u003e\n\u003cul style=\"margin: 12px 0 0; padding-left: 18px;\"\u003e\n\u003cli\u003e\n\u003cstrong\u003eHigh output comfort:\u003c\/strong\u003e designed for demanding heating and cooling needs in larger spaces.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e46°F freeze protection:\u003c\/strong\u003e added protection for cold conditions.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHigh-Frequency Racer Technology:\u003c\/strong\u003e rapid ramp to maximum speed on startup for quick comfort.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAdvanced refrigerant management:\u003c\/strong\u003e electronic expansion valve optimizes refrigerant flow control.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCleaner performance:\u003c\/strong\u003e intelligent dusting switch reverses the fan to help clear dust, sand, and debris from the coil.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eComfort automation:\u003c\/strong\u003e Follow Me, Timer On\/Off, Sleep Mode, and Turbo Mode.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cdiv aria-label=\"At-a-glance\" role=\"list\" class=\"hvx-kv\"\u003e\n\u003cdiv role=\"listitem\"\u003e\n\u003cstrong\u003eIndoor\u003c\/strong\u003eCH-R24MOLVWM-230VI\u003c\/div\u003e\n\u003cdiv role=\"listitem\"\u003e\n\u003cstrong\u003eOutdoor\u003c\/strong\u003eCH-RHP24-230VO\u003c\/div\u003e\n\u003cdiv role=\"listitem\"\u003e\n\u003cstrong\u003eLines\u003c\/strong\u003e3\/8\" liquid · 5\/8\" gas\u003c\/div\u003e\n\u003cdiv role=\"listitem\"\u003e\n\u003cstrong\u003eMax run\u003c\/strong\u003e164 ft\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"hvx-desc-card\"\u003e\n\u003ch2 class=\"hvx-section-title\"\u003eWhat’s Included\u003c\/h2\u003e\n\u003cul style=\"padding-left: 18px; margin: 8px 0;\"\u003e\n\u003cli\u003eIndoor unit: CH-R24MOLVWM-230VI\u003c\/li\u003e\n\u003cli\u003eOutdoor unit: CH-RHP24-230VO (Hyper Heating)\u003c\/li\u003e\n\u003cli\u003eRemote control\u003c\/li\u003e\n\u003cli\u003eSmart Kit (app connectivity)\u003c\/li\u003e\n\u003cli\u003eManufacturer documentation (see Downloads)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"hvx-desc-card\"\u003e\n\u003ch2 class=\"hvx-section-title\"\u003eIndoor Specs\u003c\/h2\u003e\n\u003cdiv class=\"hvx-table-wrap\"\u003e\n\u003ctable aria-label=\"Indoor unit specifications\" class=\"hvx-table\"\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eSpec\u003c\/th\u003e\n\u003cth\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIndoor Model\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCH-R24MOLVWM-230VI\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower Supply (Rated)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e208\/230 V, 1 Ø, 60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Capacity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e23,000 Btu\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMinimum Circuit Ampacity (MCA)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMax. fuse (A)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e15\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIndoor Air Flow (Turbo\/Hi\/Med\/Lo\/Si) (CFM)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e759.3 \/ 588.6 \/ 459.1 \/ 382.6 \/ N\/A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIndoor Noise Level (Turbo\/Hi\/Med\/Lo\/Si) dB(A)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e54.5 \/ 49.5 \/ 43.5 \/ 34.5 \/ 20.5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimension (W×D×H) (in)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e42.60 × 9.21 × 13.27\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePacking (W×D×H) (in)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e45.47 × 12.40 × 16.34\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNet\/Gross Weight (lb)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e30.86 \/ 40.56\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRoom Temperature (Cooling) (°F)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e60–90\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRoom Temperature (Heating) (°F)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e32–86\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRefrigerant piping Liquid\/Gas side (inch)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3\/8\" \/ 5\/8\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"hvx-desc-card\"\u003e\n\u003ch2 class=\"hvx-section-title\"\u003eOutdoor Specs\u003c\/h2\u003e\n\u003cdiv class=\"hvx-table-wrap\"\u003e\n\u003ctable aria-label=\"Outdoor unit specifications\" class=\"hvx-table\"\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eSpec\u003c\/th\u003e\n\u003cth\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCH-RHP24-230VO\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRefrigerant type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eR454B\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBTU Rated\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e24,000\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower source\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e208-230V, 1Ph, 60Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eVoltage range (V)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e187-253\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRefrigerant piping Liquid\/Gas side (inch)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3\/8\" \/ 5\/8\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMax. pipe length (ft)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e164\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMax height difference between Indoor and Outdoor unit\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e82\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCooling capacity (Min\/Max) (BTU\/h)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e24,000 (12,600~27,900)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eHeating capacity (Min\/Max) (Btu\/h)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e29,000 (11,800~29,700)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eHSPF2-5\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e9.8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eHSPF2-4\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e13.5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCOP\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3.42\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDehumidification value (pnt\/day)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e5.71\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOutdoor Noise Level\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e61.5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOutdoor Air Flow\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2,235.3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMinimum circuit ampacity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e24.9\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMax.fuse\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e25\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAmbient temperature - Heating (F)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-22~75\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAmbient temperature - Cooling (F)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-22 ~ 122\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eUnit dimensions (W*H*D)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e37.24 x 16.14 x 31.89\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eUnit Net\/Gross weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e130.29\/141.31\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePacking dimensions (WxDxH)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e42.91 x 19.68 x 34.84\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRefrigerant precharge\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e25\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAdditional Refrigerant Charge 3\/8 liquid line\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.32\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"hvx-desc-card\"\u003e\n\u003ch2 class=\"hvx-section-title\"\u003eDocuments \u0026amp; Downloads\u003c\/h2\u003e\n\u003cul style=\"padding-left: 18px; margin: 8px 0;\"\u003e\n\u003cli\u003e\u003ca rel=\"noopener\" href=\"https:\/\/media.cooperandhunter.us\/4730\/CH-RES24-230VO_CH-R24MOLVWM-230VI.pdf\" target=\"_blank\"\u003eSubmittal (PDF): CH-R24MOLVWM-230VI (Link 1)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca rel=\"noopener\" href=\"https:\/\/drive.google.com\/file\/d\/11uCRDvBhIcMpwvzipwSXF-SzHNnvy1ty\/view?usp=drive_link\" class=\"hvx-link\" target=\"_blank\"\u003eSubmittal (PDF): CH-R24MOLVWM-230VI (Link 2)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca rel=\"noopener\" href=\"https:\/\/media.cooperandhunter.us\/3959\/CH-RHP24-230VO-%2B-CH-RS24MAHU.pdf\" class=\"hvx-link\" target=\"_blank\"\u003eSubmittal (PDF): CH-RHP24-230VO + CH-RS24MAHU\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca rel=\"noopener\" href=\"https:\/\/media.cooperandhunter.us\/4160\/CH-RHP24-230VO-%2B-CH-PRO24MASTWM-230VI.pdf\" class=\"hvx-link\" target=\"_blank\"\u003eSubmittal (PDF): CH-RHP24-230VO + CH-PRO24MASTWM-230VI\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca rel=\"noopener\" href=\"https:\/\/media.cooperandhunter.us\/4174\/CH-RHP24-230VO-%2B-CH-RH24MASTWM-230VI.pdf\" class=\"hvx-link\" target=\"_blank\"\u003eSubmittal (PDF): CH-RHP24-230VO + CH-RH24MASTWM-230VI\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca rel=\"noopener\" href=\"https:\/\/media.cooperandhunter.us\/4205\/CH-RHP24-230VO-%2B-CH-RS24MDT-HS.pdf\" class=\"hvx-link\" target=\"_blank\"\u003eSubmittal (PDF): CH-RHP24-230VO + CH-RS24MDT-HS\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca rel=\"noopener\" href=\"https:\/\/media.cooperandhunter.us\/4631\/CH-RHP24-230VO_CH-RSH24MFC.pdf\" class=\"hvx-link\" target=\"_blank\"\u003eSubmittal (PDF): CH-RHP24-230VO + CH-RSH24MFC\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca rel=\"noopener\" href=\"https:\/\/media.cooperandhunter.us\/4688\/CH-RHP24-230VO_CH-RH24MCT.pdf\" class=\"hvx-link\" target=\"_blank\"\u003eSubmittal (PDF): CH-RHP24-230VO + CH-RH24MCT\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca rel=\"noopener\" href=\"https:\/\/media.cooperandhunter.us\/4118\/Installation-Manual-R454B-Outdoor-units--.pdf\" class=\"hvx-link\" target=\"_blank\"\u003eInstallation Manual (PDF): R454B Outdoor Units\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca rel=\"noopener\" href=\"https:\/\/media.cooperandhunter.us\/4200\/SlimDuct-Leaflet-R454B.pdf\" class=\"hvx-link\" target=\"_blank\"\u003eLeaflet (PDF): SlimDuct — R454B\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca rel=\"noopener\" href=\"https:\/\/cooperandhunter.us\/product\/ch-rhp24-230vo\" class=\"hvx-link\" target=\"_blank\"\u003eManufacturer Page: CH-RHP24-230VO\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca rel=\"noopener\" href=\"https:\/\/www.ahridirectory.org\" class=\"hvx-link\" target=\"_blank\"\u003eAHRI Directory Listing: 207742320\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"hvx-desc-card\"\u003e\n\u003ch2 class=\"hvx-section-title\"\u003eImportant\u003c\/h2\u003e\n\u003cp style=\"margin: 0; font-size: 14px; color: var(--hvx-slate);\"\u003eProfessional installation is recommended. Confirm electrical requirements, line sizes, maximum line length, and ambient operating limits before installation.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"hvx-desc-card\"\u003e\n\u003ch2 class=\"hvx-section-title\"\u003eFAQs\u003c\/h2\u003e\n\u003cdetails open=\"\" class=\"hvx-faq\"\u003e\n\u003csummary\u003eIs this system Hyper Heat?\u003c\/summary\u003e\n\u003cdiv style=\"margin-top: 8px;\"\u003eYes—Hyper Heating operation is rated down to −22°F.\u003c\/div\u003e\n\u003c\/details\u003e\n\u003cdetails open=\"\" class=\"hvx-faq\"\u003e\n\u003csummary\u003eWhat line sizes does this system use?\u003c\/summary\u003e\n\u003cdiv style=\"margin-top: 8px;\"\u003e3\/8\" liquid and 5\/8\" gas.\u003c\/div\u003e\n\u003c\/details\u003e\n\u003cdetails open=\"\" class=\"hvx-faq\"\u003e\n\u003csummary\u003eWhat is the maximum line set length?\u003c\/summary\u003e\n\u003cdiv style=\"margin-top: 8px;\"\u003eUp to 164 ft (maximum pipe length).\u003c\/div\u003e\n\u003c\/details\u003e\n\u003cdetails open=\"\" class=\"hvx-faq\"\u003e\n\u003csummary\u003eDoes it include smart control?\u003c\/summary\u003e\n\u003cdiv style=\"margin-top: 8px;\"\u003eYes—Smart Kit is included for C\u0026amp;H app control, and a remote is included.\u003c\/div\u003e\n\u003c\/details\u003e\n\u003cdetails open=\"\" class=\"hvx-faq\"\u003e\n\u003csummary\u003eIs a wall thermostat supported?\u003c\/summary\u003e\n\u003cdiv style=\"margin-top: 8px;\"\u003eYes—wall thermostat compatibility is available (thermostat sold separately).\u003c\/div\u003e\n\u003c\/details\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e","brand":"Cooper\u0026Hunter","offers":[{"title":"No installation","offer_id":42673012113451,"sku":"CH-R24MOLVWM-230VI + CH-RHP24-230VO","price":2499.0,"currency_code":"USD","in_stock":true},{"title":"16FT","offer_id":42673012146219,"sku":"CH-R24MOLVWM-230VI + CH-RHP24-230VO","price":2715.0,"currency_code":"USD","in_stock":true},{"title":"25FT","offer_id":42673012178987,"sku":"CH-R24MOLVWM-230VI + CH-RHP24-230VO","price":2845.0,"currency_code":"USD","in_stock":true},{"title":"50FT","offer_id":42673012211755,"sku":"CH-R24MOLVWM-230VI + CH-RHP24-230VO","price":3152.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0625\/5647\/1339\/files\/5_aef7a478-a314-4dcb-ab91-aa8b5cc28844.png?v=1769199804"},{"product_id":"cooper-hunter-9-000-btu-olivia-single-zone-wall-mount-minisplit-heat-pump-system-r454b-230v","title":"Cooper\u0026Hunter 9,000 BTU Olivia Single Zone Wall Mount Minisplit Heat Pump System R454B 230V","description":"\u003cstyle\u003e\n  :root{\n    --hvx-golden:#FAA819;\n    --hvx-slate:#262626;\n    --hvx-ivory:#F4F1E6;\n    --hvx-border:#e2e0d5;\n    --hvx-card-bg:#ffffff;\n  }\n\n  .hvx-desc{\n    font-family:\"Articulat CF\",system-ui,-apple-system,BlinkMacSystemFont,\"Segoe UI\",sans-serif;\n    color:var(--hvx-slate);\n    line-height:1.6;\n    background:var(--hvx-ivory);\n    padding:18px 18px 20px;\n    border-radius:16px;\n  }\n\n  .hvx-desc-header{\n    border-radius:14px;\n    padding:14px 16px;\n    background:linear-gradient(120deg,var(--hvx-golden),var(--hvx-slate));\n    color:#fff;\n    margin:0 0 16px;\n    box-shadow:0 10px 24px rgba(0,0,0,.22);\n    display:flex;\n    align-items:flex-start;\n    gap:12px;\n    flex-wrap:wrap;\n  }\n\n  .hvx-header-text{display:flex;flex-direction:column;gap:6px;min-width:260px}\n  .hvx-eyebrow{\n    font-size:11px;\n    letter-spacing:.14em;\n    text-transform:uppercase;\n    opacity:.9;\n  }\n  .hvx-title{\n    margin:0;\n    font-family:\"Anton\",\"Impact\",system-ui,-apple-system,BlinkMacSystemFont,\"Segoe UI\",sans-serif;\n    font-size:22px;\n    line-height:1.15;\n  }\n  .hvx-subtitle{margin:0;font-size:14px;opacity:.95}\n\n  .hvx-desc-card{\n    border:1px solid var(--hvx-border);\n    border-radius:14px;\n    background:var(--hvx-card-bg);\n    padding:16px 18px 18px;\n    box-shadow:0 4px 12px rgba(0,0,0,.06);\n    margin:14px 0;\n  }\n\n  .hvx-section-title{\n    margin:0 0 10px;\n    font-family:\"Anton\",\"Impact\",system-ui,-apple-system,BlinkMacSystemFont,\"Segoe UI\",sans-serif;\n    font-size:17px;\n    letter-spacing:.08em;\n    text-transform:uppercase;\n    color:var(--hvx-slate);\n    display:inline-flex;\n    align-items:center;\n    gap:8px;\n  }\n  .hvx-section-title::after{\n    content:\"\";\n    flex:1;\n    height:2px;\n    border-radius:999px;\n    background:linear-gradient(90deg,var(--hvx-golden),transparent);\n    opacity:.9;\n  }\n\n  .hvx-cta{display:flex;flex-wrap:wrap;gap:10px;margin:10px 0 0}\n  .hvx-cta a{\n    display:inline-flex;\n    align-items:center;\n    gap:8px;\n    padding:10px 14px;\n    border-radius:12px;\n    border:1px solid var(--hvx-border);\n    background:#fff;\n    text-decoration:none;\n    color:var(--hvx-slate);\n    font-size:14px;\n    font-weight:700;\n  }\n  .hvx-cta a.primary{\n    background:var(--hvx-slate);\n    color:#fff;\n    border-color:transparent;\n  }\n\n  .hvx-badges{display:flex;flex-wrap:wrap;gap:8px;margin:10px 0 0}\n  .hvx-badge{\n    font-size:12px;\n    border:1px solid var(--hvx-border);\n    border-radius:999px;\n    padding:6px 10px;\n    background:#fff;\n    white-space:nowrap;\n  }\n\n  .hvx-kv{\n    display:grid;\n    grid-template-columns:repeat(4,minmax(160px,1fr));\n    gap:10px;\n    margin-top:10px;\n  }\n  .hvx-kv \u003e div{\n    border:1px solid var(--hvx-border);\n    background:#fff;\n    border-radius:12px;\n    padding:10px 12px;\n    text-align:center;\n  }\n  .hvx-kv strong{display:block}\n\n  .hvx-table{\n    width:100%;\n    border-collapse:collapse;\n    min-width:520px;\n    background:#fff;\n    border:1px solid var(--hvx-border);\n    border-radius:12px;\n    overflow:hidden;\n  }\n  .hvx-table th,.hvx-table td{\n    border-bottom:1px solid var(--hvx-border);\n    padding:10px 12px;\n    vertical-align:top;\n    font-size:14px;\n  }\n  .hvx-table th{ text-align:left; font-weight:800; background:#fff; }\n  .hvx-table tr:nth-child(even) td{ background:#fbfaf6; }\n  .hvx-table tr:last-child td{ border-bottom:none; }\n  .hvx-table-wrap{ overflow:auto; border-radius:12px; }\n\n  .hvx-link{color:var(--hvx-slate); text-decoration:underline; text-underline-offset:2px}\n  .hvx-link:hover{opacity:.85}\n\n  details.hvx-faq{\n    border:1px solid var(--hvx-border);\n    background:#fff;\n    border-radius:12px;\n    padding:10px 12px;\n    margin:8px 0;\n  }\n  details.hvx-faq summary{cursor:pointer;font-weight:800}\n\n  @media(max-width:980px){\n    .hvx-kv{grid-template-columns:repeat(2,minmax(160px,1fr))}\n  }\n  @media(max-width:768px){\n    .hvx-desc{padding:14px 12px 16px;border-radius:12px}\n    .hvx-desc-header{padding:12px;border-radius:12px}\n    .hvx-title{font-size:19px}\n    .hvx-desc-card{padding:14px;margin:10px 0}\n  }\n\u003c\/style\u003e\n\u003cdiv class=\"hvx-desc\"\u003e\n\u003cdiv class=\"hvx-desc-header\"\u003e\n\u003cdiv class=\"hvx-header-text\"\u003e\n\u003cdiv class=\"hvx-eyebrow\"\u003eCooper\u0026amp;Hunter Olivia • R454B • Single Zone\u003c\/div\u003e\n\u003ch1 class=\"hvx-title\"\u003eCooper\u0026amp;Hunter 9,000 BTU Olivia Single Zone Wall Mount Mini Split Heat Pump System R454B 230V\u003c\/h1\u003e\n\u003cp class=\"hvx-subtitle\"\u003e\u003cstrong\u003eSKU:\u003c\/strong\u003e CH-R09MOLVWM-230VI + CH-RES09-230VO\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"hvx-cta\" aria-label=\"Contact options\"\u003e\n\u003ca class=\"primary\" href=\"https:\/\/hvacsupplies.com\/pages\/contact\" rel=\"noopener\" title=\"Contact Us\" target=\"_blank\"\u003e CLICK HERE TO CONTACT US FOR CUSTOM QUOTES AND QUESTIONS \u003c\/a\u003e \u003ca href=\"tel:+18005438933\" title=\"Call Us Now!\"\u003eCLICK TO CALL US 800-543-8933 FOR ANY QUESTIONS\u003c\/a\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"hvx-desc-card\"\u003e\n\u003ch2 class=\"hvx-section-title\"\u003eOverview\u003c\/h2\u003e\n\u003cp style=\"margin: 0;\"\u003eEnhance your home's climate control with the Cooper\u0026amp;Hunter \u003cstrong\u003e9K BTU Olivia\u003c\/strong\u003e wall-mounted mini split utilizing \u003cstrong\u003eR454B\u003c\/strong\u003e refrigerant for improved efficiency and a lower environmental impact. With \u003cstrong\u003eup to 24.6 SEER2\u003c\/strong\u003e performance in 230V, this single-zone system delivers modern comfort features, quiet operation, and smart control options for efficient heating and cooling.\u003c\/p\u003e\n\u003cp style=\"margin: 10px 0 0;\"\u003eAuto-swing horizontal louvers help reduce hot\/cold spots, while inverter technology adjusts compressor output to match demand for steady comfort and energy savings. Controls include a Smart Kit for C\u0026amp;H app control, an included remote, and optional wall thermostat compatibility (sold separately).\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"hvx-desc-card\"\u003e\n\u003ch2 class=\"hvx-section-title\"\u003eHighlights\u003c\/h2\u003e\n\u003cdiv class=\"hvx-badges\" role=\"list\"\u003e\n\u003cspan class=\"hvx-badge\" role=\"listitem\"\u003e9,000 BTU class\u003c\/span\u003e \u003cspan class=\"hvx-badge\" role=\"listitem\"\u003eR454B refrigerant\u003c\/span\u003e \u003cspan class=\"hvx-badge\" role=\"listitem\"\u003eUp to 24.6 SEER2\u003c\/span\u003e \u003cspan class=\"hvx-badge\" role=\"listitem\"\u003e208–230V, 1Ph, 60Hz\u003c\/span\u003e \u003cspan class=\"hvx-badge\" role=\"listitem\"\u003eSmart Kit (App control)\u003c\/span\u003e \u003cspan class=\"hvx-badge\" role=\"listitem\"\u003eAuto-swing (horizontal louvers)\u003c\/span\u003e \u003cspan class=\"hvx-badge\" role=\"listitem\"\u003eTU1 copper tubes\u003c\/span\u003e\n\u003c\/div\u003e\n\u003cul style=\"margin: 12px 0 0; padding-left: 18px;\"\u003e\n\u003cli\u003e\n\u003cstrong\u003eGenius Core low-speed operation:\u003c\/strong\u003e ultra-low compressor speed (12Hz) for quiet, efficient comfort.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e46°F freeze protection:\u003c\/strong\u003e added protection for cold conditions.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHigh-Frequency Racer Technology:\u003c\/strong\u003e rapid ramp to maximum speed on startup for quick comfort.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eElectronic expansion valve:\u003c\/strong\u003e optimizes refrigerant flow management.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIntelligent dusting switch:\u003c\/strong\u003e reverses the fan to help clear dust, sand, and debris from the coil.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eComfort automation:\u003c\/strong\u003e Follow Me, Timer On\/Off, Sleep Mode, and Turbo Mode.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cdiv class=\"hvx-kv\" role=\"list\" aria-label=\"At-a-glance\"\u003e\n\u003cdiv role=\"listitem\"\u003e\n\u003cstrong\u003eIndoor\u003c\/strong\u003eCH-R09MOLVWM-230VI\u003c\/div\u003e\n\u003cdiv role=\"listitem\"\u003e\n\u003cstrong\u003eOutdoor\u003c\/strong\u003eCH-RES09-230VO\u003c\/div\u003e\n\u003cdiv role=\"listitem\"\u003e\n\u003cstrong\u003eLines\u003c\/strong\u003e1\/4\" liquid · 3\/8\" gas\u003c\/div\u003e\n\u003cdiv role=\"listitem\"\u003e\n\u003cstrong\u003eMax run\u003c\/strong\u003e82 ft\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"hvx-desc-card\"\u003e\n\u003ch2 class=\"hvx-section-title\"\u003eWhat’s Included\u003c\/h2\u003e\n\u003cul style=\"padding-left: 18px; margin: 8px 0;\"\u003e\n\u003cli\u003eIndoor unit: CH-R09MOLVWM-230VI\u003c\/li\u003e\n\u003cli\u003eOutdoor unit: CH-RES09-230VO\u003c\/li\u003e\n\u003cli\u003eRemote control\u003c\/li\u003e\n\u003cli\u003eSmart Kit (app connectivity)\u003c\/li\u003e\n\u003cli\u003eManufacturer documentation (see Downloads)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"hvx-desc-card\"\u003e\n\u003ch2 class=\"hvx-section-title\"\u003eIndoor Specs\u003c\/h2\u003e\n\u003cdiv class=\"hvx-table-wrap\"\u003e\n\u003ctable class=\"hvx-table\" aria-label=\"Indoor unit specifications\"\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eSpec\u003c\/th\u003e\n\u003cth\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIndoor Model\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCH-R09MOLVWM-230VI\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower Supply (Rated)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e208\/230 V, 1 Ø, 60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Capacity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e9,000 Btu\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMinimum Circuit Ampacity (MCA)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMax. fuse (A)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e15\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIndoor Air Flow (Turbo\/Hi\/Med\/Lo\/Si) (CFM)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e382.6 \/ 294.3 \/ 194.2 \/ 153.0 \/ N\/A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIndoor Noise Level (Turbo\/Hi\/Med\/Lo\/Si) dB(A)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eN\/A \/ 39.5 \/ 33 \/ 24 \/ 20.5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimension (W×D×H) (in)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e31.57 × 7.87 × 11.61\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePacking (W×D×H) (in)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e31.57 × 7.87 × 11.61\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNet\/Gross Weight (lb)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e18.96 \/ 24.25\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRoom Temperature (Cooling) (°F)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e60–90\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRoom Temperature (Heating) (°F)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e32–86\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRefrigerant piping Liquid\/Gas side (inch)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1\/4\" \/ 3\/8\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"hvx-desc-card\"\u003e\n\u003ch2 class=\"hvx-section-title\"\u003eOutdoor Specs\u003c\/h2\u003e\n\u003cdiv class=\"hvx-table-wrap\"\u003e\n\u003ctable class=\"hvx-table\" aria-label=\"Outdoor unit specifications\"\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eSpec\u003c\/th\u003e\n\u003cth\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCH-RES09-230VO\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSystem type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSingle-zone unit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRefrigerant type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eR454B\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBTU Rated\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e9,000\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower source\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e208-230V, 1Ph, 60Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eVoltage range (V)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e187-253\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRefrigerant piping Liquid\/Gas side (inch)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1\/4\" \/ 3\/8\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMax. pipe length (ft)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e82\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMax height difference between Indoor and Outdoor unit\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e49.2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCooling capacity (Min\/Max) (BTU\/h)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e9,000 (3,100~11,900)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eHeating capacity (Min\/Max) (Btu\/h)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e10,000 (3,600~14,000)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSEER2\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e19.5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEER2\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e12.8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eHSPF2-5\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e8.8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eHSPF2-4\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e11\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCOP\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3.66\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDehumidification value (pnt\/day)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1.44\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOutdoor Noise Level\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e54\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOutdoor Air Flow\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1,236.1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMinimum circuit ampacity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e12\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMax.fuse\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e15\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAmbient temperature - Heating (F)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-13~75\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAmbient temperature - Cooling (F)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-13 ~ 122\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eUnit dimensions (W*H*D)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e30.12 x 11.93 x 21.85\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eUnit Net\/Gross weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e62.17\/67.68\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePacking dimensions (WxDxH)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e34.92 x 13.27 x 24.02\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRefrigerant precharge\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e25\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAdditional Refrigerant Charge 1\/4 liquid line\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.16\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"hvx-desc-card\"\u003e\n\u003ch2 class=\"hvx-section-title\"\u003eDocuments \u0026amp; Downloads\u003c\/h2\u003e\n\u003cul style=\"padding-left: 18px; margin: 8px 0;\"\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/media.cooperandhunter.us\/4728\/CH-RES09-230VO_CH-R09MOLVWM-230VI.pdf\" target=\"_blank\" rel=\"noopener\"\u003eSubmittal (PDF): CH-R09MOLVWM-230VI (Link 1)\u003c\/a\u003e\u003ca rel=\"noopener\" href=\"https:\/\/media.cooperandhunter.us\/3119\/CH-ES09-230VO-%2B-CH-09MOLVWM-230VI.pdf\" target=\"_blank\"\u003e\u003c\/a\u003e\n\u003c\/li\u003e\n\u003cli\u003e\u003ca class=\"hvx-link\" href=\"https:\/\/drive.google.com\/file\/d\/11uCRDvBhIcMpwvzipwSXF-SzHNnvy1ty\/view?usp=drive_link\" rel=\"noopener\" target=\"_blank\"\u003eSubmittal (PDF): CH-R09MOLVWM-230VI (Link 2)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca class=\"hvx-link\" href=\"https:\/\/media.cooperandhunter.us\/4166\/CH-RES09-230VO-%2B-CH-RH09MASTWM-230VI.pdf\" rel=\"noopener\" target=\"_blank\"\u003eSubmittal (PDF): CH-RES09-230VO + CH-RH09MASTWM-230VI\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca class=\"hvx-link\" href=\"https:\/\/media.cooperandhunter.us\/4164\/CH-RES09-230VO-%2B-CH-PRO09MASTWM-230VI.pdf\" rel=\"noopener\" target=\"_blank\"\u003eSubmittal (PDF): CH-RES09-230VO + CH-PRO09MASTWM-230VI\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca class=\"hvx-link\" href=\"https:\/\/media.cooperandhunter.us\/4209\/CH-RES09-230VO-%2B-CH-RS06-12MDT--MS.pdf\" rel=\"noopener\" target=\"_blank\"\u003eSubmittal (PDF): CH-RES09-230VO + CH-RS06-12MDT--MS\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca class=\"hvx-link\" href=\"https:\/\/media.cooperandhunter.us\/4675\/CH-RES09-230VO_CH-RH09MCT.pdf\" rel=\"noopener\" target=\"_blank\"\u003eSubmittal (PDF): CH-RES09-230VO + CH-RH09MCT\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca class=\"hvx-link\" href=\"https:\/\/media.cooperandhunter.us\/4674\/CH-RES09-230VO_CH-RSH09MCT.pdf\" rel=\"noopener\" target=\"_blank\"\u003eSubmittal (PDF): CH-RES09-230VO + CH-RSH09MCT\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca class=\"hvx-link\" href=\"https:\/\/media.cooperandhunter.us\/4118\/Installation-Manual-R454B-Outdoor-units--.pdf\" rel=\"noopener\" target=\"_blank\"\u003eInstallation Manual (PDF): R454B Outdoor Units\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca class=\"hvx-link\" href=\"https:\/\/media.cooperandhunter.us\/4200\/SlimDuct-Leaflet-R454B.pdf\" rel=\"noopener\" target=\"_blank\"\u003eLeaflet (PDF): SlimDuct — R454B\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca class=\"hvx-link\" href=\"https:\/\/cooperandhunter.us\/product\/ch-res09-230vo\" rel=\"noopener\" target=\"_blank\"\u003eManufacturer Page: CH-RES09-230VO\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca class=\"hvx-link\" href=\"https:\/\/www.ahridirectory.org\/NewSearch?programId=41\u0026amp;searchTypeId=3\u0026amp;productTypeId=4\" rel=\"noopener\" target=\"_blank\"\u003eAHRI Directory Listing: 207742317\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"hvx-desc-card\"\u003e\n\u003ch2 class=\"hvx-section-title\"\u003eImportant\u003c\/h2\u003e\n\u003cp style=\"margin: 0; font-size: 14px; color: var(--hvx-slate);\"\u003eProfessional installation is recommended. Confirm electrical requirements, line sizes, maximum line length, and ambient operating limits before installation.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"hvx-desc-card\"\u003e\n\u003ch2 class=\"hvx-section-title\"\u003eFAQs\u003c\/h2\u003e\n\u003cdetails class=\"hvx-faq\" open=\"\"\u003e\n\u003csummary\u003eIs this a Hyper Heat system?\u003c\/summary\u003e\n\u003cdiv style=\"margin-top: 8px;\"\u003eNo—this is the Regular (non-Hyper) outdoor unit.\u003c\/div\u003e\n\u003c\/details\u003e\n\u003cdetails class=\"hvx-faq\" open=\"\"\u003e\n\u003csummary\u003eWhat line sizes does this system use?\u003c\/summary\u003e\n\u003cdiv style=\"margin-top: 8px;\"\u003e1\/4\" liquid and 3\/8\" gas.\u003c\/div\u003e\n\u003c\/details\u003e\n\u003cdetails class=\"hvx-faq\" open=\"\"\u003e\n\u003csummary\u003eWhat is the maximum line set length?\u003c\/summary\u003e\n\u003cdiv style=\"margin-top: 8px;\"\u003eUp to 82 ft (maximum pipe length).\u003c\/div\u003e\n\u003c\/details\u003e\n\u003cdetails class=\"hvx-faq\" open=\"\"\u003e\n\u003csummary\u003eDoes it include smart control?\u003c\/summary\u003e\n\u003cdiv style=\"margin-top: 8px;\"\u003eYes—Smart Kit is included for C\u0026amp;H app control, and a remote is included.\u003c\/div\u003e\n\u003c\/details\u003e\n\u003cdetails class=\"hvx-faq\" open=\"\"\u003e\n\u003csummary\u003eWhat is the rated outdoor operating range?\u003c\/summary\u003e\n\u003cdiv style=\"margin-top: 8px;\"\u003eHeating: -13°F to 75°F. Cooling: -13°F to 122°F.\u003c\/div\u003e\n\u003c\/details\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e","brand":"Cooper\u0026Hunter","offers":[{"title":"No installation","offer_id":42673014210603,"sku":"CH-R09MOLVWM-230VI + CH-RES09-230VO","price":1241.0,"currency_code":"USD","in_stock":true},{"title":"16FT","offer_id":42673014243371,"sku":"CH-R09MOLVWM-230VI + CH-RES09-230VO","price":1423.0,"currency_code":"USD","in_stock":true},{"title":"25FT","offer_id":42673014276139,"sku":"CH-R09MOLVWM-230VI + CH-RES09-230VO","price":1469.0,"currency_code":"USD","in_stock":true},{"title":"50FT","offer_id":42673014308907,"sku":"CH-R09MOLVWM-230VI + CH-RES09-230VO","price":1689.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0625\/5647\/1339\/files\/36k230v_16a9455a-6937-4bc9-8fb1-956232357d10.png?v=1769199738"},{"product_id":"cooper-hunter-12-000-btu-olivia-single-zone-wall-mount-minisplit-heat-pump-system-r454b-230v","title":"Cooper\u0026Hunter 12,000 BTU Olivia Single Zone Wall Mount Minisplit Heat Pump System R454B 230V","description":"\u003cstyle\u003e\n  :root{\n    --hvx-golden:#FAA819;\n    --hvx-slate:#262626;\n    --hvx-ivory:#F4F1E6;\n    --hvx-border:#e2e0d5;\n    --hvx-card-bg:#ffffff;\n  }\n\n  .hvx-desc{\n    font-family:\"Articulat CF\",system-ui,-apple-system,BlinkMacSystemFont,\"Segoe UI\",sans-serif;\n    color:var(--hvx-slate);\n    line-height:1.6;\n    background:var(--hvx-ivory);\n    padding:18px 18px 20px;\n    border-radius:16px;\n  }\n\n  .hvx-desc-header{\n    border-radius:14px;\n    padding:14px 16px;\n    background:linear-gradient(120deg,var(--hvx-golden),var(--hvx-slate));\n    color:#fff;\n    margin:0 0 16px;\n    box-shadow:0 10px 24px rgba(0,0,0,.22);\n    display:flex;\n    align-items:flex-start;\n    gap:12px;\n    flex-wrap:wrap;\n  }\n\n  .hvx-header-text{display:flex;flex-direction:column;gap:6px;min-width:260px}\n  .hvx-eyebrow{\n    font-size:11px;\n    letter-spacing:.14em;\n    text-transform:uppercase;\n    opacity:.9;\n  }\n  .hvx-title{\n    margin:0;\n    font-family:\"Anton\",\"Impact\",system-ui,-apple-system,BlinkMacSystemFont,\"Segoe UI\",sans-serif;\n    font-size:22px;\n    line-height:1.15;\n  }\n  .hvx-subtitle{margin:0;font-size:14px;opacity:.95}\n\n  .hvx-desc-card{\n    border:1px solid var(--hvx-border);\n    border-radius:14px;\n    background:var(--hvx-card-bg);\n    padding:16px 18px 18px;\n    box-shadow:0 4px 12px rgba(0,0,0,.06);\n    margin:14px 0;\n  }\n\n  .hvx-section-title{\n    margin:0 0 10px;\n    font-family:\"Anton\",\"Impact\",system-ui,-apple-system,BlinkMacSystemFont,\"Segoe UI\",sans-serif;\n    font-size:17px;\n    letter-spacing:.08em;\n    text-transform:uppercase;\n    color:var(--hvx-slate);\n    display:inline-flex;\n    align-items:center;\n    gap:8px;\n  }\n  .hvx-section-title::after{\n    content:\"\";\n    flex:1;\n    height:2px;\n    border-radius:999px;\n    background:linear-gradient(90deg,var(--hvx-golden),transparent);\n    opacity:.9;\n  }\n\n  .hvx-cta{display:flex;flex-wrap:wrap;gap:10px;margin:10px 0 0}\n  .hvx-cta a{\n    display:inline-flex;\n    align-items:center;\n    gap:8px;\n    padding:10px 14px;\n    border-radius:12px;\n    border:1px solid var(--hvx-border);\n    background:#fff;\n    text-decoration:none;\n    color:var(--hvx-slate);\n    font-size:14px;\n    font-weight:700;\n  }\n  .hvx-cta a.primary{\n    background:var(--hvx-slate);\n    color:#fff;\n    border-color:transparent;\n  }\n\n  .hvx-badges{display:flex;flex-wrap:wrap;gap:8px;margin:10px 0 0}\n  .hvx-badge{\n    font-size:12px;\n    border:1px solid var(--hvx-border);\n    border-radius:999px;\n    padding:6px 10px;\n    background:#fff;\n    white-space:nowrap;\n  }\n\n  .hvx-kv{\n    display:grid;\n    grid-template-columns:repeat(4,minmax(160px,1fr));\n    gap:10px;\n    margin-top:10px;\n  }\n  .hvx-kv \u003e div{\n    border:1px solid var(--hvx-border);\n    background:#fff;\n    border-radius:12px;\n    padding:10px 12px;\n    text-align:center;\n  }\n  .hvx-kv strong{display:block}\n\n  .hvx-table{\n    width:100%;\n    border-collapse:collapse;\n    min-width:520px;\n    background:#fff;\n    border:1px solid var(--hvx-border);\n    border-radius:12px;\n    overflow:hidden;\n  }\n  .hvx-table th,.hvx-table td{\n    border-bottom:1px solid var(--hvx-border);\n    padding:10px 12px;\n    vertical-align:top;\n    font-size:14px;\n  }\n  .hvx-table th{ text-align:left; font-weight:800; background:#fff; }\n  .hvx-table tr:nth-child(even) td{ background:#fbfaf6; }\n  .hvx-table tr:last-child td{ border-bottom:none; }\n  .hvx-table-wrap{ overflow:auto; border-radius:12px; }\n\n  .hvx-link{color:var(--hvx-slate); text-decoration:underline; text-underline-offset:2px}\n  .hvx-link:hover{opacity:.85}\n\n  details.hvx-faq{\n    border:1px solid var(--hvx-border);\n    background:#fff;\n    border-radius:12px;\n    padding:10px 12px;\n    margin:8px 0;\n  }\n  details.hvx-faq summary{cursor:pointer;font-weight:800}\n\n  @media(max-width:980px){\n    .hvx-kv{grid-template-columns:repeat(2,minmax(160px,1fr))}\n  }\n  @media(max-width:768px){\n    .hvx-desc{padding:14px 12px 16px;border-radius:12px}\n    .hvx-desc-header{padding:12px;border-radius:12px}\n    .hvx-title{font-size:19px}\n    .hvx-desc-card{padding:14px;margin:10px 0}\n  }\n\u003c\/style\u003e\n\u003cdiv class=\"hvx-desc\"\u003e\n\u003cdiv class=\"hvx-desc-header\"\u003e\n\u003cdiv class=\"hvx-header-text\"\u003e\n\u003cdiv class=\"hvx-eyebrow\"\u003eCooper\u0026amp;Hunter Olivia • R454B • Single Zone\u003c\/div\u003e\n\u003ch1 class=\"hvx-title\"\u003eCooper\u0026amp;Hunter 12,000 BTU Olivia Single Zone Wall Mount Mini Split Heat Pump System R454B 230V\u003c\/h1\u003e\n\u003cp class=\"hvx-subtitle\"\u003e\u003cstrong\u003eSKU:\u003c\/strong\u003e CH-R12MOLVWM-230VI + CH-RES12-230VO\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"hvx-cta\" aria-label=\"Contact options\"\u003e\n\u003ca class=\"primary\" href=\"https:\/\/hvacsupplies.com\/pages\/contact\" rel=\"noopener\" title=\"Contact Us\" target=\"_blank\"\u003e CLICK HERE TO CONTACT US FOR CUSTOM QUOTES AND QUESTIONS \u003c\/a\u003e \u003ca href=\"tel:+18005438933\" title=\"Call Us Now!\"\u003eCLICK TO CALL US 800-543-8933 FOR ANY QUESTIONS\u003c\/a\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"hvx-desc-card\"\u003e\n\u003ch2 class=\"hvx-section-title\"\u003eOverview\u003c\/h2\u003e\n\u003cp style=\"margin: 0;\"\u003eEnhance your home's climate control with the Cooper\u0026amp;Hunter \u003cstrong\u003e12K BTU Olivia\u003c\/strong\u003e wall-mounted mini split utilizing the new \u003cstrong\u003eR454B\u003c\/strong\u003e refrigerant. Designed for efficient heating and cooling in 230V single-zone applications, it combines inverter performance with comfort features and smart connectivity.\u003c\/p\u003e\n\u003cp style=\"margin: 10px 0 0;\"\u003eAuto-swing horizontal louvers help reduce hot\/cold spots, while inverter technology adjusts output to match demand for steady comfort and energy savings. Control options include Smart Kit app control, an included remote, and optional wall thermostat compatibility (sold separately).\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"hvx-desc-card\"\u003e\n\u003ch2 class=\"hvx-section-title\"\u003eHighlights\u003c\/h2\u003e\n\u003cdiv class=\"hvx-badges\" role=\"list\"\u003e\n\u003cspan class=\"hvx-badge\" role=\"listitem\"\u003e12,000 BTU class\u003c\/span\u003e \u003cspan class=\"hvx-badge\" role=\"listitem\"\u003eR454B refrigerant\u003c\/span\u003e \u003cspan class=\"hvx-badge\" role=\"listitem\"\u003eUp to 23.1 SEER2\u003c\/span\u003e \u003cspan class=\"hvx-badge\" role=\"listitem\"\u003e208–230V, 1Ph, 60Hz\u003c\/span\u003e \u003cspan class=\"hvx-badge\" role=\"listitem\"\u003eSmart Kit (App control)\u003c\/span\u003e \u003cspan class=\"hvx-badge\" role=\"listitem\"\u003eAuto-swing (horizontal louvers)\u003c\/span\u003e \u003cspan class=\"hvx-badge\" role=\"listitem\"\u003eTU1 copper tubes\u003c\/span\u003e \u003cspan class=\"hvx-badge\" role=\"listitem\"\u003eRegular (Non-Hyper) Outdoor\u003c\/span\u003e\n\u003c\/div\u003e\n\u003cul style=\"margin: 12px 0 0; padding-left: 18px;\"\u003e\n\u003cli\u003e\n\u003cstrong\u003eGenius Core low-speed operation:\u003c\/strong\u003e ultra-low compressor speed (12Hz) for quiet, efficient comfort.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e46°F freeze protection:\u003c\/strong\u003e added protection for cold conditions.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHigh-Frequency Racer Technology:\u003c\/strong\u003e rapid ramp to maximum speed on startup for quick comfort.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eElectronic expansion valve:\u003c\/strong\u003e optimizes refrigerant flow management.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIntelligent dusting switch:\u003c\/strong\u003e reverses the fan to help clear dust, sand, and debris from the coil.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eComfort automation:\u003c\/strong\u003e Follow Me, Timer On\/Off, Sleep Mode, Eco Mode (Single-Zone only), Self-Clean (Single-Zone only), and Turbo Mode.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cdiv class=\"hvx-kv\" role=\"list\" aria-label=\"At-a-glance\"\u003e\n\u003cdiv role=\"listitem\"\u003e\n\u003cstrong\u003eIndoor\u003c\/strong\u003eCH-R12MOLVWM-230VI\u003c\/div\u003e\n\u003cdiv role=\"listitem\"\u003e\n\u003cstrong\u003eOutdoor\u003c\/strong\u003eCH-RES12-230VO\u003c\/div\u003e\n\u003cdiv role=\"listitem\"\u003e\n\u003cstrong\u003eLines\u003c\/strong\u003e1\/4\" liquid · 3\/8\" gas\u003c\/div\u003e\n\u003cdiv role=\"listitem\"\u003e\n\u003cstrong\u003eMax run\u003c\/strong\u003e82 ft\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"hvx-desc-card\"\u003e\n\u003ch2 class=\"hvx-section-title\"\u003eWhat’s Included\u003c\/h2\u003e\n\u003cul style=\"padding-left: 18px; margin: 8px 0;\"\u003e\n\u003cli\u003eIndoor unit: CH-R12MOLVWM-230VI\u003c\/li\u003e\n\u003cli\u003eOutdoor unit: CH-RES12-230VO\u003c\/li\u003e\n\u003cli\u003eRemote control\u003c\/li\u003e\n\u003cli\u003eSmart Kit (app connectivity)\u003c\/li\u003e\n\u003cli\u003eManufacturer documentation (see Downloads)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"hvx-desc-card\"\u003e\n\u003ch2 class=\"hvx-section-title\"\u003eIndoor Specs\u003c\/h2\u003e\n\u003cdiv class=\"hvx-table-wrap\"\u003e\n\u003ctable class=\"hvx-table\" aria-label=\"Indoor unit specifications\"\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eSpec\u003c\/th\u003e\n\u003cth\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIndoor Model\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCH-R12MOLVWM-230VI\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower Supply (Rated)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e208\/230 V, 1 Ø, 60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Capacity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e12,000 Btu\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMinimum Circuit Ampacity (MCA)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMax. fuse (A)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e15\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIndoor Air Flow (Turbo\/Hi\/Med\/Lo\/Si) (CFM)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e382.6 \/ 294.3 \/ 194.2 \/ 153.0 \/ —\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIndoor Noise Level (Turbo\/Hi\/Med\/Lo\/Si) dB(A)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eN\/A \/ 42 \/ 35.5 \/ 22.5 \/ 20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimension (W×D×H) (in)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e31.57 × 7.87 × 11.61\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePacking (W×D×H) (in)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e31.57 × 7.87 × 11.61\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNet\/Gross Weight (lb)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e18.96 \/ 24.25\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRoom Temperature (Cooling) (°F)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e60–90\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRoom Temperature (Heating) (°F)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e32–86\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRefrigerant piping Liquid\/Gas side (inch)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1\/4\" \/ 3\/8\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"hvx-desc-card\"\u003e\n\u003ch2 class=\"hvx-section-title\"\u003eOutdoor Specs\u003c\/h2\u003e\n\u003cdiv class=\"hvx-table-wrap\"\u003e\n\u003ctable class=\"hvx-table\" aria-label=\"Outdoor unit specifications\"\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eSpec\u003c\/th\u003e\n\u003cth\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCH-RES12-230VO\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSystem type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSingle-zone unit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRefrigerant type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eR454B\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBTU Rated\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e12,000\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower source\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e208-230V, 1Ph, 60Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eVoltage range (V)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e187-253\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRefrigerant piping Liquid\/Gas side (inch)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1\/4\" \/ 3\/8\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMax. pipe length (ft)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e82\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMax height difference between Indoor and Outdoor unit\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e49.2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCooling capacity (Min\/Max) (BTU\/h)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e11,500 (3,100~13,000)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eHeating capacity (Min\/Max) (Btu\/h)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e12,000 (3,700~15,600)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSEER2\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e19\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEER2\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e11.7\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eHSPF2-5\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eHSPF2-4\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e10.2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCOP\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3.42\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDehumidification value (pnt\/day)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2.09\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOutdoor Noise Level\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e55.5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOutdoor Air Flow\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1,236.1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMinimum circuit ampacity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e12\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMax.fuse\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e15\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAmbient temperature - Heating (F)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-13~75\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAmbient temperature - Cooling (F)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-13 ~ 122\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eUnit dimensions (W*H*D)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e30.12 x 11.93 x 21.85\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eUnit Net\/Gross weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e62.17\/67.68\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePacking dimensions (WxDxH)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e34.92 x 13.27 x 24.02\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRefrigerant precharge\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e25\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAdditional Refrigerant Charge 1\/4 liquid line\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.16\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"hvx-desc-card\"\u003e\n\u003ch2 class=\"hvx-section-title\"\u003eDocuments \u0026amp; Downloads\u003c\/h2\u003e\n\u003cul style=\"padding-left: 18px; margin: 8px 0;\"\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/media.cooperandhunter.us\/4729\/CH-RES12-230VO_CH-R12MOLVWM-230VI.pdf\" target=\"_blank\" rel=\"noopener\"\u003eSubmittal (PDF): CH-R12MOLVWM-230VI (Link 1)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca class=\"hvx-link\" href=\"https:\/\/drive.google.com\/file\/d\/11uCRDvBhIcMpwvzipwSXF-SzHNnvy1ty\/view?usp=drive_link\" rel=\"noopener\" target=\"_blank\"\u003eSubmittal (PDF): CH-R12MOLVWM-230VI (Link 2)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca class=\"hvx-link\" href=\"https:\/\/media.cooperandhunter.us\/4156\/CH-RES12-230VO-%2B-CH-PRO12MASTWM-230VI.pdf\" rel=\"noopener\" target=\"_blank\"\u003eSubmittal (PDF): CH-RES12-230VO + CH-PRO12MASTWM-230VI\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca class=\"hvx-link\" href=\"https:\/\/media.cooperandhunter.us\/4169\/CH-RES12-230VO-%2B-CH-RH12MASTWM-230VI.pdf\" rel=\"noopener\" target=\"_blank\"\u003eSubmittal (PDF): CH-RES12-230VO + CH-RH12MASTWM-230VI\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca class=\"hvx-link\" href=\"https:\/\/media.cooperandhunter.us\/4210\/CH-RES12-230VO-%2B-CH-RS06-12MDT--MS.pdf\" rel=\"noopener\" target=\"_blank\"\u003eSubmittal (PDF): CH-RES12-230VO + CH-RS06-12MDT--MS\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca class=\"hvx-link\" href=\"https:\/\/media.cooperandhunter.us\/4677\/CH-RES12-230VO_CH-RSH12MCT.pdf\" rel=\"noopener\" target=\"_blank\"\u003eSubmittal (PDF): CH-RES12-230VO + CH-RSH12MCT\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca class=\"hvx-link\" href=\"https:\/\/media.cooperandhunter.us\/4676\/CH-RES12-230VO_CH-RH12MCT.pdf\" rel=\"noopener\" target=\"_blank\"\u003eSubmittal (PDF): CH-RES12-230VO + CH-RH12MCT\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca class=\"hvx-link\" href=\"https:\/\/media.cooperandhunter.us\/4118\/Installation-Manual-R454B-Outdoor-units--.pdf\" rel=\"noopener\" target=\"_blank\"\u003eInstallation Manual (PDF): R454B Outdoor Units\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca class=\"hvx-link\" href=\"https:\/\/media.cooperandhunter.us\/4200\/SlimDuct-Leaflet-R454B.pdf\" rel=\"noopener\" target=\"_blank\"\u003eLeaflet (PDF): SlimDuct — R454B\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca class=\"hvx-link\" href=\"https:\/\/cooperandhunter.us\/product\/ch-res12-230vo\" rel=\"noopener\" target=\"_blank\"\u003eManufacturer Page: CH-RES12-230VO\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca class=\"hvx-link\" href=\"https:\/\/www.ahridirectory.org\/NewSearch?programId=41\u0026amp;searchTypeId=3\u0026amp;productTypeId=4\" rel=\"noopener\" target=\"_blank\"\u003eAHRI Directory Listing: 207742320\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"hvx-desc-card\"\u003e\n\u003ch2 class=\"hvx-section-title\"\u003eImportant\u003c\/h2\u003e\n\u003cp style=\"margin: 0; font-size: 14px; color: var(--hvx-slate);\"\u003eProfessional installation is recommended. Confirm electrical requirements, line sizes, maximum line length, and ambient operating limits before installation.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"hvx-desc-card\"\u003e\n\u003ch2 class=\"hvx-section-title\"\u003eFAQs\u003c\/h2\u003e\n\u003cdetails class=\"hvx-faq\" open=\"\"\u003e\n\u003csummary\u003eIs this a Hyper Heat system?\u003c\/summary\u003e\n\u003cdiv style=\"margin-top: 8px;\"\u003eNo—this is the Regular (non-Hyper) outdoor unit.\u003c\/div\u003e\n\u003c\/details\u003e\n\u003cdetails class=\"hvx-faq\" open=\"\"\u003e\n\u003csummary\u003eWhat line sizes does this system use?\u003c\/summary\u003e\n\u003cdiv style=\"margin-top: 8px;\"\u003e1\/4\" liquid and 3\/8\" gas.\u003c\/div\u003e\n\u003c\/details\u003e\n\u003cdetails class=\"hvx-faq\" open=\"\"\u003e\n\u003csummary\u003eWhat is the maximum line set length?\u003c\/summary\u003e\n\u003cdiv style=\"margin-top: 8px;\"\u003eUp to 82 ft (maximum pipe length).\u003c\/div\u003e\n\u003c\/details\u003e\n\u003cdetails class=\"hvx-faq\" open=\"\"\u003e\n\u003csummary\u003eDoes it include smart control?\u003c\/summary\u003e\n\u003cdiv style=\"margin-top: 8px;\"\u003eSmart Kit is listed as included, and a remote is included.\u003c\/div\u003e\n\u003c\/details\u003e\n\u003cdetails class=\"hvx-faq\" open=\"\"\u003e\n\u003csummary\u003eWhat is the rated outdoor operating range?\u003c\/summary\u003e\n\u003cdiv style=\"margin-top: 8px;\"\u003eHeating: -13°F to 75°F. Cooling: -13°F to 122°F.\u003c\/div\u003e\n\u003c\/details\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e","brand":"Cooper\u0026Hunter","offers":[{"title":"No installation","offer_id":42673055891499,"sku":"CH-R12MOLVWM-230VI + CH-RES12-230VO","price":1302.0,"currency_code":"USD","in_stock":true},{"title":"16FT","offer_id":42673055924267,"sku":"CH-R12MOLVWM-230VI + CH-RES12-230VO","price":1483.0,"currency_code":"USD","in_stock":true},{"title":"25FT","offer_id":42673055957035,"sku":"CH-R12MOLVWM-230VI + CH-RES12-230VO","price":1529.0,"currency_code":"USD","in_stock":true},{"title":"50FT","offer_id":42673055989803,"sku":"CH-R12MOLVWM-230VI + CH-RES12-230VO","price":1750.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0625\/5647\/1339\/files\/36k230v_16a9455a-6937-4bc9-8fb1-956232357d10.png?v=1769199738"},{"product_id":"cooper-hunter-18-000-btu-olivia-single-zone-wall-mount-minisplit-heat-pump-system-r454b-230v","title":"Cooper\u0026Hunter 18,000 BTU Olivia Single Zone Wall Mount Minisplit Heat Pump System R454B 230V","description":"\u003cstyle\u003e\n  :root{\n    --hvx-golden:#FAA819;\n    --hvx-slate:#262626;\n    --hvx-ivory:#F4F1E6;\n    --hvx-border:#e2e0d5;\n    --hvx-card-bg:#ffffff;\n  }\n\n  .hvx-desc{\n    font-family:\"Articulat CF\",system-ui,-apple-system,BlinkMacSystemFont,\"Segoe UI\",sans-serif;\n    color:var(--hvx-slate);\n    line-height:1.6;\n    background:var(--hvx-ivory);\n    padding:18px 18px 20px;\n    border-radius:16px;\n  }\n\n  .hvx-desc-header{\n    border-radius:14px;\n    padding:14px 16px;\n    background:linear-gradient(120deg,var(--hvx-golden),var(--hvx-slate));\n    color:#fff;\n    margin:0 0 16px;\n    box-shadow:0 10px 24px rgba(0,0,0,.22);\n    display:flex;\n    align-items:flex-start;\n    gap:12px;\n    flex-wrap:wrap;\n  }\n\n  .hvx-header-text{display:flex;flex-direction:column;gap:6px;min-width:260px}\n  .hvx-eyebrow{\n    font-size:11px;\n    letter-spacing:.14em;\n    text-transform:uppercase;\n    opacity:.9;\n  }\n  .hvx-title{\n    margin:0;\n    font-family:\"Anton\",\"Impact\",system-ui,-apple-system,BlinkMacSystemFont,\"Segoe UI\",sans-serif;\n    font-size:22px;\n    line-height:1.15;\n  }\n  .hvx-subtitle{margin:0;font-size:14px;opacity:.95}\n\n  .hvx-desc-card{\n    border:1px solid var(--hvx-border);\n    border-radius:14px;\n    background:var(--hvx-card-bg);\n    padding:16px 18px 18px;\n    box-shadow:0 4px 12px rgba(0,0,0,.06);\n    margin:14px 0;\n  }\n\n  .hvx-section-title{\n    margin:0 0 10px;\n    font-family:\"Anton\",\"Impact\",system-ui,-apple-system,BlinkMacSystemFont,\"Segoe UI\",sans-serif;\n    font-size:17px;\n    letter-spacing:.08em;\n    text-transform:uppercase;\n    color:var(--hvx-slate);\n    display:inline-flex;\n    align-items:center;\n    gap:8px;\n  }\n  .hvx-section-title::after{\n    content:\"\";\n    flex:1;\n    height:2px;\n    border-radius:999px;\n    background:linear-gradient(90deg,var(--hvx-golden),transparent);\n    opacity:.9;\n  }\n\n  .hvx-cta{display:flex;flex-wrap:wrap;gap:10px;margin:10px 0 0}\n  .hvx-cta a{\n    display:inline-flex;\n    align-items:center;\n    gap:8px;\n    padding:10px 14px;\n    border-radius:12px;\n    border:1px solid var(--hvx-border);\n    background:#fff;\n    text-decoration:none;\n    color:var(--hvx-slate);\n    font-size:14px;\n    font-weight:700;\n  }\n  .hvx-cta a.primary{\n    background:var(--hvx-slate);\n    color:#fff;\n    border-color:transparent;\n  }\n\n  .hvx-badges{display:flex;flex-wrap:wrap;gap:8px;margin:10px 0 0}\n  .hvx-badge{\n    font-size:12px;\n    border:1px solid var(--hvx-border);\n    border-radius:999px;\n    padding:6px 10px;\n    background:#fff;\n    white-space:nowrap;\n  }\n\n  .hvx-kv{\n    display:grid;\n    grid-template-columns:repeat(4,minmax(160px,1fr));\n    gap:10px;\n    margin-top:10px;\n  }\n  .hvx-kv \u003e div{\n    border:1px solid var(--hvx-border);\n    background:#fff;\n    border-radius:12px;\n    padding:10px 12px;\n    text-align:center;\n  }\n  .hvx-kv strong{display:block}\n\n  .hvx-table{\n    width:100%;\n    border-collapse:collapse;\n    min-width:520px;\n    background:#fff;\n    border:1px solid var(--hvx-border);\n    border-radius:12px;\n    overflow:hidden;\n  }\n  .hvx-table th,.hvx-table td{\n    border-bottom:1px solid var(--hvx-border);\n    padding:10px 12px;\n    vertical-align:top;\n    font-size:14px;\n  }\n  .hvx-table th{ text-align:left; font-weight:800; background:#fff; }\n  .hvx-table tr:nth-child(even) td{ background:#fbfaf6; }\n  .hvx-table tr:last-child td{ border-bottom:none; }\n  .hvx-table-wrap{ overflow:auto; border-radius:12px; }\n\n  .hvx-link{color:var(--hvx-slate); text-decoration:underline; text-underline-offset:2px}\n  .hvx-link:hover{opacity:.85}\n\n  details.hvx-faq{\n    border:1px solid var(--hvx-border);\n    background:#fff;\n    border-radius:12px;\n    padding:10px 12px;\n    margin:8px 0;\n  }\n  details.hvx-faq summary{cursor:pointer;font-weight:800}\n\n  @media(max-width:980px){\n    .hvx-kv{grid-template-columns:repeat(2,minmax(160px,1fr))}\n  }\n  @media(max-width:768px){\n    .hvx-desc{padding:14px 12px 16px;border-radius:12px}\n    .hvx-desc-header{padding:12px;border-radius:12px}\n    .hvx-title{font-size:19px}\n    .hvx-desc-card{padding:14px;margin:10px 0}\n  }\n\u003c\/style\u003e\n\u003cdiv class=\"hvx-desc\"\u003e\n\u003cdiv class=\"hvx-desc-header\"\u003e\n\u003cdiv class=\"hvx-header-text\"\u003e\n\u003cdiv class=\"hvx-eyebrow\"\u003eCooper\u0026amp;Hunter Olivia • R454B • Inverter\u003c\/div\u003e\n\u003ch1 class=\"hvx-title\"\u003eCooper\u0026amp;Hunter 18,000 BTU Olivia Single Zone Wall Mount Mini Split Heat Pump System R454B 230V\u003c\/h1\u003e\n\u003cp class=\"hvx-subtitle\"\u003e\u003cstrong\u003eSKU:\u003c\/strong\u003e CH-R18MOLVWM-230VI + CH-RES18-230VO\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"hvx-cta\" aria-label=\"Contact options\"\u003e\n\u003ca class=\"primary\" href=\"https:\/\/hvacsupplies.com\/pages\/contact\" rel=\"noopener\" title=\"Contact Us\" target=\"_blank\"\u003e CLICK HERE TO CONTACT US FOR CUSTOM QUOTES AND QUESTIONS \u003c\/a\u003e \u003ca href=\"tel:+18005438933\" title=\"Call Us Now!\"\u003e CLICK TO CALL US 800-543-8933 FOR ANY QUESTIONS \u003c\/a\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"hvx-desc-card\"\u003e\n\u003ch2 class=\"hvx-section-title\"\u003eOverview\u003c\/h2\u003e\n\u003cp style=\"margin: 0;\"\u003eUpgrade comfort and efficiency with the Cooper\u0026amp;Hunter \u003cstrong\u003e18K BTU Olivia\u003c\/strong\u003e wall-mounted mini split heat pump system. Built around the new \u003cstrong\u003eR454B refrigerant\u003c\/strong\u003e, Olivia delivers modern inverter performance with lower environmental impact, designed for \u003cstrong\u003e208–230V\u003c\/strong\u003e applications. Enjoy strong, steady temperature control for medium to larger spaces with quiet operation and efficient modulation based on real-time demand.\u003c\/p\u003e\n\u003cp style=\"margin: 10px 0 0;\"\u003eOlivia is packed with advanced comfort features: \u003cstrong\u003eAuto-Swing\u003c\/strong\u003e horizontal louvers for better air circulation, \u003cstrong\u003eTurbo Mode\u003c\/strong\u003e for rapid heating\/cooling, and \u003cstrong\u003eFollow Me\u003c\/strong\u003e temperature sensing via the remote. The included \u003cstrong\u003eSmart Kit\u003c\/strong\u003e provides seamless app control through the C\u0026amp;H mobile experience. Durability is enhanced with \u003cstrong\u003eTU1 copper tubes\u003c\/strong\u003e for efficient heat transfer and long-term reliability, plus protective operation features such as \u003cstrong\u003e46° Freeze Protection\u003c\/strong\u003e.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"hvx-desc-card\"\u003e\n\u003ch2 class=\"hvx-section-title\"\u003eHighlights\u003c\/h2\u003e\n\u003cdiv class=\"hvx-badges\" role=\"list\"\u003e\n\u003cspan class=\"hvx-badge\" role=\"listitem\"\u003e18,000 BTU class\u003c\/span\u003e \u003cspan class=\"hvx-badge\" role=\"listitem\"\u003eR454B refrigerant\u003c\/span\u003e \u003cspan class=\"hvx-badge\" role=\"listitem\"\u003eInverter-driven performance\u003c\/span\u003e \u003cspan class=\"hvx-badge\" role=\"listitem\"\u003eSmart Kit included\u003c\/span\u003e \u003cspan class=\"hvx-badge\" role=\"listitem\"\u003eAuto-swing (horizontal louvers)\u003c\/span\u003e \u003cspan class=\"hvx-badge\" role=\"listitem\"\u003eTurbo Mode\u003c\/span\u003e \u003cspan class=\"hvx-badge\" role=\"listitem\"\u003e46° Freeze Protection\u003c\/span\u003e \u003cspan class=\"hvx-badge\" role=\"listitem\"\u003e208–230V, 1Ph, 60Hz\u003c\/span\u003e\n\u003c\/div\u003e\n\u003cul style=\"margin: 12px 0 0; padding-left: 18px;\"\u003e\n\u003cli\u003e\n\u003cstrong\u003eGenius Core performance:\u003c\/strong\u003e ultra-low compressor speed (12Hz) for quiet, efficient comfort.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFast response comfort:\u003c\/strong\u003e High-Frequency Racer Technology targets rapid temperature control on startup.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePrecision refrigerant management:\u003c\/strong\u003e electronic expansion valve (EEV) optimizes flow control.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCleaner coil operation:\u003c\/strong\u003e intelligent dusting switch reverses the fan to help clear dust, sand, and debris from the coil.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eControl options:\u003c\/strong\u003e Smart Kit with app control, included remote control, wall thermostat optional (sold separately).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSingle-zone outdoor included:\u003c\/strong\u003e CH-RES18-230VO outdoor unit is a single-zone inverter condenser.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cdiv class=\"hvx-kv\" role=\"list\" aria-label=\"At-a-glance\"\u003e\n\u003cdiv role=\"listitem\"\u003e\n\u003cstrong\u003eIndoor\u003c\/strong\u003eCH-R18MOLVWM-230VI\u003c\/div\u003e\n\u003cdiv role=\"listitem\"\u003e\n\u003cstrong\u003eOutdoor\u003c\/strong\u003eCH-RES18-230VO\u003c\/div\u003e\n\u003cdiv role=\"listitem\"\u003e\n\u003cstrong\u003eLines\u003c\/strong\u003e1\/4\" liquid · 1\/2\" gas\u003c\/div\u003e\n\u003cdiv role=\"listitem\"\u003e\n\u003cstrong\u003eMax run\u003c\/strong\u003e98.4 ft\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"hvx-desc-card\"\u003e\n\u003ch2 class=\"hvx-section-title\"\u003eWhat’s Included\u003c\/h2\u003e\n\u003cul style=\"padding-left: 18px; margin: 8px 0;\"\u003e\n\u003cli\u003eIndoor unit: CH-R18MOLVWM-230VI\u003c\/li\u003e\n\u003cli\u003eOutdoor unit: CH-RES18-230VO (Single-Zone)\u003c\/li\u003e\n\u003cli\u003eRemote control (included)\u003c\/li\u003e\n\u003cli\u003eSmart Kit (included) for app control\u003c\/li\u003e\n\u003cli\u003eManufacturer documentation (see Documents \u0026amp; Downloads)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"hvx-desc-card\"\u003e\n\u003ch2 class=\"hvx-section-title\"\u003eIndoor Specs\u003c\/h2\u003e\n\u003cdiv class=\"hvx-table-wrap\"\u003e\n\u003ctable class=\"hvx-table\" aria-label=\"Indoor unit specifications\"\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eSpec\u003c\/th\u003e\n\u003cth\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCH-R18MOLVWM-230VI\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower supply (rated)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e208\/230 V, 1 Ø, 60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated capacity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e18,000 BTU\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMinimum circuit ampacity (MCA)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMax fuse\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e15\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIndoor air flow (Turbo\/Hi\/Med\/Lo\/Si)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e759.3 \/ 500.3 \/ 441.4 \/ 370.8 \/ (not listed)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIndoor noise (Turbo\/Hi\/Med\/Lo\/Si)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e54.5 \/ 45 \/ 40 \/ 24.5 \/ 20 dB(A)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (W×D×H)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e42.60 × 9.21 × 13.27 in\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePacking (W×D×H)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e45.47 × 12.40 × 16.34 in\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNet \/ Gross weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e30.42 \/ 39.68 lb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRoom temperature (Cooling)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e60–90°F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRoom temperature (Heating)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e32–86°F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRefrigerant piping (liq\/gas)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1\/4\" \/ 1\/2\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"hvx-desc-card\"\u003e\n\u003ch2 class=\"hvx-section-title\"\u003eOutdoor Specs\u003c\/h2\u003e\n\u003cdiv class=\"hvx-table-wrap\"\u003e\n\u003ctable class=\"hvx-table\" aria-label=\"Outdoor unit specifications\"\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eSpec\u003c\/th\u003e\n\u003cth\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCH-RES18-230VO\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSystem type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSingle-zone unit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRefrigerant type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eR454B\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBTU rated\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e18,000\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower source\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e208–230V, 1Ph, 60Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eVoltage range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e187–253 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRefrigerant piping (liq\/gas)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1\/4\" \/ 1\/2\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMax pipe length\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e98.4 ft\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMax height difference (IDU↔ODU)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e65.6 ft\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCooling capacity (Min\/Max)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e17,000 (7,000–19,000) BTU\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eHeating capacity (Min\/Max)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e20,000 (5,500–22,000) BTU\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSEER2\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEER2\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e12.5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eHSPF2-5\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e8.2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eHSPF2-4\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e10.5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCOP\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3.47\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDehumidification\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3.09 pnt\/day\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOutdoor noise level\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e59 dB(A)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOutdoor air flow\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1,765.8 CFM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMinimum circuit ampacity (MCA)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e18\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMax fuse\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAmbient temperature (Heating)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e−13–75°F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAmbient temperature (Cooling)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e−13–122°F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eUnit dimensions (W×H×D)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e35.04 × 13.46 × 26.5 in\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNet \/ Gross weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e92.59 \/ 100.31 lb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePacking dimensions (W×D×H)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e39.17 × 15.67 × 29.13 in\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRefrigerant precharge\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e25\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAdditional charge (1\/4\" liquid)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.16\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"hvx-desc-card\"\u003e\n\u003ch2 class=\"hvx-section-title\"\u003eDocuments \u0026amp; Downloads\u003c\/h2\u003e\n\u003cul style=\"padding-left: 18px; margin: 8px 0;\"\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/media.cooperandhunter.us\/4770\/CH-RHP18-230VO_CH-R18MOLVWM-230VI.pdf\" target=\"_blank\" rel=\"noopener\"\u003eSubmittal (PDF) — Olivia 18K (Drive) #1\u003c\/a\u003e\u003ca class=\"hvx-link\" href=\"https:\/\/drive.google.com\/file\/d\/1ihW7qIoZeIA7wdy_Ucobosp4e-QB_8H0\/view?usp=drive_link\" rel=\"noopener\" target=\"_blank\"\u003e\u003c\/a\u003e\n\u003c\/li\u003e\n\u003cli\u003e\u003ca class=\"hvx-link\" href=\"https:\/\/drive.google.com\/file\/d\/11uCRDvBhIcMpwvzipwSXF-SzHNnvy1ty\/view?usp=drive_link\" rel=\"noopener\" target=\"_blank\"\u003eSubmittal (PDF) — Olivia 18K (Drive) #2\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca class=\"hvx-link\" href=\"https:\/\/media.cooperandhunter.us\/4157\/CH-RES18-230VO-%2B-CH-PRO18MASTWM-230VI.pdf\" rel=\"noopener\" target=\"_blank\"\u003eSubmittal (PDF) — CH-RES18-230VO + CH-PRO18MASTWM-230VI\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca class=\"hvx-link\" href=\"https:\/\/media.cooperandhunter.us\/4171\/CH-RES18-230VO-%2B-CH-RH18MASTWM-230VI.pdf\" rel=\"noopener\" target=\"_blank\"\u003eSubmittal (PDF) — CH-RES18-230VO + CH-RH18MASTWM-230VI\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca class=\"hvx-link\" href=\"https:\/\/media.cooperandhunter.us\/4211\/CH-RES18-230VO-%2B-CH-RS18MDT-MS.pdf\" rel=\"noopener\" target=\"_blank\"\u003eSubmittal (PDF) — CH-RES18-230VO + CH-RS18MDT-MS\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca class=\"hvx-link\" href=\"https:\/\/media.cooperandhunter.us\/4625\/CH-RES18-230VO_CH-RSH18MFC.pdf\" rel=\"noopener\" target=\"_blank\"\u003eSubmittal (PDF) — CH-RES18-230VO + CH-RSH18MFC\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca class=\"hvx-link\" href=\"https:\/\/media.cooperandhunter.us\/4679\/CH-RES18-230VO_CH-RSH18MCT.pdf\" rel=\"noopener\" target=\"_blank\"\u003eSubmittal (PDF) — CH-RES18-230VO + CH-RSH18MCT\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca class=\"hvx-link\" href=\"https:\/\/media.cooperandhunter.us\/4678\/CH-RES18-230VO_CH-RH18MCT.pdf\" rel=\"noopener\" target=\"_blank\"\u003eSubmittal (PDF) — CH-RES18-230VO + CH-RH18MCT\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca class=\"hvx-link\" href=\"https:\/\/media.cooperandhunter.us\/4118\/Installation-Manual-R454B-Outdoor-units--.pdf\" rel=\"noopener\" target=\"_blank\"\u003eInstallation Manual (PDF) — R454B Outdoor Units\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca class=\"hvx-link\" href=\"https:\/\/media.cooperandhunter.us\/4200\/SlimDuct-Leaflet-R454B.pdf\" rel=\"noopener\" target=\"_blank\"\u003eSlimDuct Leaflet (PDF) — R454B\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca class=\"hvx-link\" href=\"https:\/\/www.ahridirectory.org\/NewSearch?programId=41\u0026amp;searchTypeId=3\u0026amp;productTypeId=4\" rel=\"noopener\" target=\"_blank\"\u003eAHRI Directory Listing — AHRI #207742320\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca class=\"hvx-link\" href=\"https:\/\/cooperandhunter.us\/product\/ch-res18-230vo\" rel=\"noopener\" target=\"_blank\"\u003eManufacturer Page — CH-RES18-230VO\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"hvx-desc-card\"\u003e\n\u003ch2 class=\"hvx-section-title\"\u003eImportant\u003c\/h2\u003e\n\u003cp style=\"margin: 0; font-size: 14px; color: var(--hvx-slate);\"\u003eProfessional installation is recommended. Confirm electrical requirements, line sizes, maximum line length, and ambient operating limits before installation. Verify local code requirements and manufacturer guidelines prior to startup.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"hvx-desc-card\"\u003e\n\u003ch2 class=\"hvx-section-title\"\u003eFAQs\u003c\/h2\u003e\n\u003cdetails class=\"hvx-faq\" open=\"\"\u003e\n\u003csummary\u003eWhat line sizes does this system use?\u003c\/summary\u003e\n\u003cdiv style=\"margin-top: 8px;\"\u003e1\/4\" liquid and 1\/2\" gas.\u003c\/div\u003e\n\u003c\/details\u003e\n\u003cdetails class=\"hvx-faq\" open=\"\"\u003e\n\u003csummary\u003eIs the Smart Kit included?\u003c\/summary\u003e\n\u003cdiv style=\"margin-top: 8px;\"\u003eYes. The Olivia system includes a Smart Kit for app control, plus an included remote controller.\u003c\/div\u003e\n\u003c\/details\u003e\n\u003cdetails class=\"hvx-faq\" open=\"\"\u003e\n\u003csummary\u003eWhat is the outdoor heating and cooling ambient range?\u003c\/summary\u003e\n\u003cdiv style=\"margin-top: 8px;\"\u003eCooling: −13–122°F. Heating: −13–75°F.\u003c\/div\u003e\n\u003c\/details\u003e\n\u003cdetails class=\"hvx-faq\" open=\"\"\u003e\n\u003csummary\u003eWhat comfort features are included?\u003c\/summary\u003e\n\u003cdiv style=\"margin-top: 8px;\"\u003eAuto-Swing horizontal louvers, Turbo Mode, Follow Me mode, Timer On\/Off, Sleep Mode, and protective operation including 46° Freeze Protection.\u003c\/div\u003e\n\u003c\/details\u003e\n\u003cdetails class=\"hvx-faq\" open=\"\"\u003e\n\u003csummary\u003eWhat controls are supported?\u003c\/summary\u003e\n\u003cdiv style=\"margin-top: 8px;\"\u003eSmart Kit app control and included remote control; wall thermostat is optional (sold separately).\u003c\/div\u003e\n\u003c\/details\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e","brand":"Cooper\u0026Hunter","offers":[{"title":"No installation","offer_id":42675381141547,"sku":"CH-R18MOLVWM-230VI + CH-RES18-230VO","price":1796.0,"currency_code":"USD","in_stock":true},{"title":"16FT","offer_id":42675381174315,"sku":"CH-R18MOLVWM-230VI + CH-RES18-230VO","price":2004.0,"currency_code":"USD","in_stock":true},{"title":"25FT","offer_id":42675381207083,"sku":"CH-R18MOLVWM-230VI + CH-RES18-230VO","price":2049.0,"currency_code":"USD","in_stock":true},{"title":"50FT","offer_id":42675381239851,"sku":"CH-R18MOLVWM-230VI + CH-RES18-230VO","price":2252.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0625\/5647\/1339\/files\/36k230v_16a9455a-6937-4bc9-8fb1-956232357d10.png?v=1769199738"},{"product_id":"cooper-hunter-24-000-btu-olivia-single-zone-wall-mount-minisplit-heat-pump-system-r454b-230v","title":"Cooper\u0026Hunter 24,000 BTU Olivia Single Zone Wall Mount Minisplit Heat Pump System R454B 230V","description":"\u003cstyle\u003e\n  :root{\n    --hvx-golden:#FAA819;\n    --hvx-slate:#262626;\n    --hvx-ivory:#F4F1E6;\n    --hvx-border:#e2e0d5;\n    --hvx-card-bg:#ffffff;\n  }\n\n  .hvx-desc{\n    font-family:\"Articulat CF\",system-ui,-apple-system,BlinkMacSystemFont,\"Segoe UI\",sans-serif;\n    color:var(--hvx-slate);\n    line-height:1.6;\n    background:var(--hvx-ivory);\n    padding:18px 18px 20px;\n    border-radius:16px;\n  }\n\n  .hvx-desc-header{\n    border-radius:14px;\n    padding:14px 16px;\n    background:linear-gradient(120deg,var(--hvx-golden),var(--hvx-slate));\n    color:#fff;\n    margin:0 0 16px;\n    box-shadow:0 10px 24px rgba(0,0,0,.22);\n    display:flex;\n    align-items:flex-start;\n    gap:12px;\n    flex-wrap:wrap;\n  }\n\n  .hvx-header-text{display:flex;flex-direction:column;gap:6px;min-width:260px}\n  .hvx-eyebrow{\n    font-size:11px;\n    letter-spacing:.14em;\n    text-transform:uppercase;\n    opacity:.9;\n  }\n  .hvx-title{\n    margin:0;\n    font-family:\"Anton\",\"Impact\",system-ui,-apple-system,BlinkMacSystemFont,\"Segoe UI\",sans-serif;\n    font-size:22px;\n    line-height:1.15;\n  }\n  .hvx-subtitle{margin:0;font-size:14px;opacity:.95}\n\n  .hvx-desc-card{\n    border:1px solid var(--hvx-border);\n    border-radius:14px;\n    background:var(--hvx-card-bg);\n    padding:16px 18px 18px;\n    box-shadow:0 4px 12px rgba(0,0,0,.06);\n    margin:14px 0;\n  }\n\n  .hvx-section-title{\n    margin:0 0 10px;\n    font-family:\"Anton\",\"Impact\",system-ui,-apple-system,BlinkMacSystemFont,\"Segoe UI\",sans-serif;\n    font-size:17px;\n    letter-spacing:.08em;\n    text-transform:uppercase;\n    color:var(--hvx-slate);\n    display:inline-flex;\n    align-items:center;\n    gap:8px;\n  }\n  .hvx-section-title::after{\n    content:\"\";\n    flex:1;\n    height:2px;\n    border-radius:999px;\n    background:linear-gradient(90deg,var(--hvx-golden),transparent);\n    opacity:.9;\n  }\n\n  .hvx-cta{display:flex;flex-wrap:wrap;gap:10px;margin:10px 0 0}\n  .hvx-cta a{\n    display:inline-flex;\n    align-items:center;\n    gap:8px;\n    padding:10px 14px;\n    border-radius:12px;\n    border:1px solid var(--hvx-border);\n    background:#fff;\n    text-decoration:none;\n    color:var(--hvx-slate);\n    font-size:14px;\n    font-weight:700;\n  }\n  .hvx-cta a.primary{\n    background:var(--hvx-slate);\n    color:#fff;\n    border-color:transparent;\n  }\n\n  .hvx-badges{display:flex;flex-wrap:wrap;gap:8px;margin:10px 0 0}\n  .hvx-badge{\n    font-size:12px;\n    border:1px solid var(--hvx-border);\n    border-radius:999px;\n    padding:6px 10px;\n    background:#fff;\n    white-space:nowrap;\n  }\n\n  .hvx-kv{\n    display:grid;\n    grid-template-columns:repeat(4,minmax(160px,1fr));\n    gap:10px;\n    margin-top:10px;\n  }\n  .hvx-kv \u003e div{\n    border:1px solid var(--hvx-border);\n    background:#fff;\n    border-radius:12px;\n    padding:10px 12px;\n    text-align:center;\n  }\n  .hvx-kv strong{display:block}\n\n  .hvx-table{\n    width:100%;\n    border-collapse:collapse;\n    min-width:520px;\n    background:#fff;\n    border:1px solid var(--hvx-border);\n    border-radius:12px;\n    overflow:hidden;\n  }\n  .hvx-table th,.hvx-table td{\n    border-bottom:1px solid var(--hvx-border);\n    padding:10px 12px;\n    vertical-align:top;\n    font-size:14px;\n  }\n  .hvx-table th{ text-align:left; font-weight:800; background:#fff; }\n  .hvx-table tr:nth-child(even) td{ background:#fbfaf6; }\n  .hvx-table tr:last-child td{ border-bottom:none; }\n  .hvx-table-wrap{ overflow:auto; border-radius:12px; }\n\n  .hvx-link{color:var(--hvx-slate); text-decoration:underline; text-underline-offset:2px}\n  .hvx-link:hover{opacity:.85}\n\n  details.hvx-faq{\n    border:1px solid var(--hvx-border);\n    background:#fff;\n    border-radius:12px;\n    padding:10px 12px;\n    margin:8px 0;\n  }\n  details.hvx-faq summary{cursor:pointer;font-weight:800}\n\n  @media(max-width:980px){\n    .hvx-kv{grid-template-columns:repeat(2,minmax(160px,1fr))}\n  }\n  @media(max-width:768px){\n    .hvx-desc{padding:14px 12px 16px;border-radius:12px}\n    .hvx-desc-header{padding:12px;border-radius:12px}\n    .hvx-title{font-size:19px}\n    .hvx-desc-card{padding:14px;margin:10px 0}\n  }\n\u003c\/style\u003e\n\u003cdiv class=\"hvx-desc\"\u003e\n\u003cdiv class=\"hvx-desc-header\"\u003e\n\u003cdiv class=\"hvx-header-text\"\u003e\n\u003cdiv class=\"hvx-eyebrow\"\u003eCooper\u0026amp;Hunter Olivia • R454B • Inverter\u003c\/div\u003e\n\u003ch1 class=\"hvx-title\"\u003eCooper\u0026amp;Hunter 24,000 BTU Olivia Single Zone Wall Mount Mini Split Heat Pump System R454B 230V\u003c\/h1\u003e\n\u003cp class=\"hvx-subtitle\"\u003e\u003cstrong\u003eSKU:\u003c\/strong\u003e CH-R24MOLVWM-230VI + CH-RES24-230VO\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv aria-label=\"Contact options\" class=\"hvx-cta\"\u003e\n\u003ca title=\"Contact Us\" rel=\"noopener\" href=\"https:\/\/hvacsupplies.com\/pages\/contact\" class=\"primary\" target=\"_blank\"\u003e CLICK HERE TO CONTACT US FOR CUSTOM QUOTES AND QUESTIONS \u003c\/a\u003e \u003ca title=\"Call Us Now!\" href=\"tel:+18005438933\"\u003e CLICK TO CALL US 800-543-8933 FOR ANY QUESTIONS \u003c\/a\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"hvx-desc-card\"\u003e\n\u003ch2 class=\"hvx-section-title\"\u003eOverview\u003c\/h2\u003e\n\u003cp style=\"margin: 0;\"\u003eEnhance your home’s climate control with the Cooper\u0026amp;Hunter \u003cstrong\u003e24K BTU Olivia\u003c\/strong\u003e wall-mounted mini split heat pump system, built around the new \u003cstrong\u003eR454B refrigerant\u003c\/strong\u003e for environmentally friendly operation and strong inverter efficiency. Designed for \u003cstrong\u003e208–230V\u003c\/strong\u003e applications, Olivia delivers reliable heating and cooling for larger spaces with quiet performance and precise temperature management.\u003c\/p\u003e\n\u003cp style=\"margin: 10px 0 0;\"\u003eAdvanced comfort and convenience features include \u003cstrong\u003eAuto-Swing\u003c\/strong\u003e horizontal louvers for improved air circulation, \u003cstrong\u003eTurbo Mode\u003c\/strong\u003e for rapid heating\/cooling, and \u003cstrong\u003eFollow Me\u003c\/strong\u003e comfort control via the remote’s temperature sensing. The included \u003cstrong\u003eSmart Kit\u003c\/strong\u003e enables seamless app connectivity through the C\u0026amp;H mobile experience. Additional technologies include a \u003cstrong\u003e12Hz\u003c\/strong\u003e low compressor speed for quiet efficiency, \u003cstrong\u003eHigh-Frequency Racer Technology\u003c\/strong\u003e for fast startup response, an \u003cstrong\u003eelectronic expansion valve\u003c\/strong\u003e for optimized refrigerant management, and an \u003cstrong\u003eintelligent dusting switch\u003c\/strong\u003e that reverses fan operation to help clear dust, sand, and debris from the coil. Built with high-quality \u003cstrong\u003eTU1 copper tubes\u003c\/strong\u003e, Olivia is engineered for durability and efficient heat transfer, with protective operation such as \u003cstrong\u003e46° Freeze Protection\u003c\/strong\u003e.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"hvx-desc-card\"\u003e\n\u003ch2 class=\"hvx-section-title\"\u003eHighlights\u003c\/h2\u003e\n\u003cdiv role=\"list\" class=\"hvx-badges\"\u003e\n\u003cspan role=\"listitem\" class=\"hvx-badge\"\u003e24,000 BTU class\u003c\/span\u003e \u003cspan role=\"listitem\" class=\"hvx-badge\"\u003eR454B refrigerant\u003c\/span\u003e \u003cspan role=\"listitem\" class=\"hvx-badge\"\u003eUp to 23.5 SEER2\u003c\/span\u003e \u003cspan role=\"listitem\" class=\"hvx-badge\"\u003eInverter-driven performance\u003c\/span\u003e \u003cspan role=\"listitem\" class=\"hvx-badge\"\u003eSmart Kit included\u003c\/span\u003e \u003cspan role=\"listitem\" class=\"hvx-badge\"\u003eAuto-swing (horizontal louvers)\u003c\/span\u003e \u003cspan role=\"listitem\" class=\"hvx-badge\"\u003eTurbo Mode\u003c\/span\u003e \u003cspan role=\"listitem\" class=\"hvx-badge\"\u003e46° Freeze Protection\u003c\/span\u003e \u003cspan role=\"listitem\" class=\"hvx-badge\"\u003e208–230V, 1Ph, 60Hz\u003c\/span\u003e\n\u003c\/div\u003e\n\u003cul style=\"margin: 12px 0 0; padding-left: 18px;\"\u003e\n\u003cli\u003e\n\u003cstrong\u003eGenius Core performance:\u003c\/strong\u003e ultra-low compressor speed (12Hz) for quiet, efficient comfort.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFast response comfort:\u003c\/strong\u003e High-Frequency Racer Technology drives rapid temperature control at startup.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePrecision refrigerant management:\u003c\/strong\u003e electronic expansion valve (EEV) optimizes refrigerant flow.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCleaner coil operation:\u003c\/strong\u003e intelligent dusting switch helps clear dust, sand, and debris from the coil.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eComfort controls:\u003c\/strong\u003e Follow Me, Timer On\/Off, Sleep Mode, Turbo Mode.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eControl options:\u003c\/strong\u003e Smart Kit with app control, included remote control, wall thermostat optional (sold separately).\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cdiv aria-label=\"At-a-glance\" role=\"list\" class=\"hvx-kv\"\u003e\n\u003cdiv role=\"listitem\"\u003e\n\u003cstrong\u003eIndoor\u003c\/strong\u003eCH-R24MOLVWM-230VI\u003c\/div\u003e\n\u003cdiv role=\"listitem\"\u003e\n\u003cstrong\u003eOutdoor\u003c\/strong\u003eCH-RES24-230VO\u003c\/div\u003e\n\u003cdiv role=\"listitem\"\u003e\n\u003cstrong\u003eLines\u003c\/strong\u003e3\/8\" liquid · 5\/8\" gas\u003c\/div\u003e\n\u003cdiv role=\"listitem\"\u003e\n\u003cstrong\u003eMax run\u003c\/strong\u003e164 ft\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"hvx-desc-card\"\u003e\n\u003ch2 class=\"hvx-section-title\"\u003eWhat’s Included\u003c\/h2\u003e\n\u003cul style=\"padding-left: 18px; margin: 8px 0;\"\u003e\n\u003cli\u003eIndoor unit: CH-R24MOLVWM-230VI\u003c\/li\u003e\n\u003cli\u003eOutdoor unit: CH-RES24-230VO (Single-Zone)\u003c\/li\u003e\n\u003cli\u003eRemote control (included)\u003c\/li\u003e\n\u003cli\u003eSmart Kit (included) for app control\u003c\/li\u003e\n\u003cli\u003eManufacturer documentation (see Documents \u0026amp; Downloads)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"hvx-desc-card\"\u003e\n\u003ch2 class=\"hvx-section-title\"\u003eIndoor Specs\u003c\/h2\u003e\n\u003cdiv class=\"hvx-table-wrap\"\u003e\n\u003ctable aria-label=\"Indoor unit specifications\" class=\"hvx-table\"\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eSpec\u003c\/th\u003e\n\u003cth\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCH-R24MOLVWM-230VI\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower supply (rated)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e208\/230 V, 1 Ø, 60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated capacity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e23,000 BTU\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMinimum circuit ampacity (MCA)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMax fuse\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e15\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIndoor air flow (Turbo\/Hi\/Med\/Lo\/Si)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e759.3 \/ 588.6 \/ 459.1 \/ 382.6 \/ (not listed)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIndoor noise (Turbo\/Hi\/Med\/Lo\/Si)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e54.5 \/ 49.5 \/ 43.5 \/ 34.5 \/ 20.5 dB(A)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (W×D×H)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e42.60 × 9.21 × 13.27 in\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePacking (W×D×H)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e45.47 × 12.40 × 16.34 in\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNet \/ Gross weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e30.86 \/ 40.56 lb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRoom temperature (Cooling)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e60–90°F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRoom temperature (Heating)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e32–86°F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRefrigerant piping (liq\/gas)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3\/8\" \/ 5\/8\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"hvx-desc-card\"\u003e\n\u003ch2 class=\"hvx-section-title\"\u003eOutdoor Specs\u003c\/h2\u003e\n\u003cdiv class=\"hvx-table-wrap\"\u003e\n\u003ctable aria-label=\"Outdoor unit specifications\" class=\"hvx-table\"\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eSpec\u003c\/th\u003e\n\u003cth\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCH-RES24-230VO\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSystem type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSingle-zone unit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRefrigerant type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eR454B\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBTU rated\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e24,000\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower source\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e208–230V, 1Ph, 60Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eVoltage range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e187–253 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRefrigerant piping (liq\/gas)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3\/8\" \/ 5\/8\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMax pipe length\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e164 ft\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMax height difference (IDU↔ODU)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e82 ft\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCooling capacity (Min\/Max)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e24,000 (8,500–28,300) BTU\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eHeating capacity (Min\/Max)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e25,000 (11,800–35,100) BTU\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSEER2\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e19\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEER2\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e12.5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eHSPF2-5\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e8.5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eHSPF2-4\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e11\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCOP\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3.64\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDehumidification\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4.52 pnt\/day\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOutdoor noise level\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e60 dB(A)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOutdoor air flow\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2,236.7 CFM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMinimum circuit ampacity (MCA)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e24\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMax fuse\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e25\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAmbient temperature (Heating)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e−13–75°F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAmbient temperature (Cooling)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e−13–122°F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eUnit dimensions (W×H×D)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e37.24 × 16.14 × 31.89 in\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNet \/ Gross weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e122.13 \/ 132.28 lb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePacking dimensions (W×D×H)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e42.91 × 19.68 × 34.84 in\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRefrigerant precharge\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e25\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAdditional charge (3\/8\" liquid)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.32\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"hvx-desc-card\"\u003e\n\u003ch2 class=\"hvx-section-title\"\u003eDocuments \u0026amp; Downloads\u003c\/h2\u003e\n\u003cul style=\"padding-left: 18px; margin: 8px 0;\"\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/media.cooperandhunter.us\/4730\/CH-RES24-230VO_CH-R24MOLVWM-230VI.pdf\" target=\"_blank\" rel=\"noopener\"\u003eSubmittal (PDF) — Olivia 24K (Drive) #1\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca rel=\"noopener\" href=\"https:\/\/drive.google.com\/file\/d\/11uCRDvBhIcMpwvzipwSXF-SzHNnvy1ty\/view?usp=drive_link\" class=\"hvx-link\" target=\"_blank\"\u003eSubmittal (PDF) — Olivia 24K (Drive) #2\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca rel=\"noopener\" href=\"https:\/\/media.cooperandhunter.us\/4159\/CH-RES24-230VO-%2B-CH-PRO24MASTWM-230VI.pdf\" class=\"hvx-link\" target=\"_blank\"\u003eSubmittal (PDF) — CH-RES24-230VO + CH-PRO24MASTWM-230VI\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca rel=\"noopener\" href=\"https:\/\/media.cooperandhunter.us\/4173\/CH-RES24-230VO-%2B-CH-RH24MASTWM-230VI.pdf\" class=\"hvx-link\" target=\"_blank\"\u003eSubmittal (PDF) — CH-RES24-230VO + CH-RH24MASTWM-230VI\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca rel=\"noopener\" href=\"https:\/\/media.cooperandhunter.us\/4212\/CH-RES24-230VO-%2B-CH-RS24MDT-HS.pdf\" class=\"hvx-link\" target=\"_blank\"\u003eSubmittal (PDF) — CH-RES24-230VO + CH-RS24MDT-HS\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca rel=\"noopener\" href=\"https:\/\/media.cooperandhunter.us\/4626\/CH-RES24-230VO_CH-RSH24MFC.pdf\" class=\"hvx-link\" target=\"_blank\"\u003eSubmittal (PDF) — CH-RES24-230VO + CH-RSH24MFC\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca rel=\"noopener\" href=\"https:\/\/media.cooperandhunter.us\/4680\/CH-RES24-230VO_CH-RH24MCT.pdf\" class=\"hvx-link\" target=\"_blank\"\u003eSubmittal (PDF) — CH-RES24-230VO + CH-RH24MCT\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca rel=\"noopener\" href=\"https:\/\/media.cooperandhunter.us\/4681\/CH-RES24-230VO_CH-RSH24MCT.pdf\" class=\"hvx-link\" target=\"_blank\"\u003eSubmittal (PDF) — CH-RES24-230VO + CH-RSH24MCT\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca rel=\"noopener\" href=\"https:\/\/media.cooperandhunter.us\/4118\/Installation-Manual-R454B-Outdoor-units--.pdf\" class=\"hvx-link\" target=\"_blank\"\u003eInstallation Manual (PDF) — R454B Outdoor Units\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca rel=\"noopener\" href=\"https:\/\/media.cooperandhunter.us\/4200\/SlimDuct-Leaflet-R454B.pdf\" class=\"hvx-link\" target=\"_blank\"\u003eSlimDuct Leaflet (PDF) — R454B\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca rel=\"noopener\" href=\"https:\/\/www.ahridirectory.org\/NewSearch?programId=41\u0026amp;searchTypeId=3\u0026amp;productTypeId=4\" class=\"hvx-link\" target=\"_blank\"\u003eAHRI Directory Listing — AHRI #207742320\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca rel=\"noopener\" href=\"https:\/\/cooperandhunter.us\/product\/ch-res24-230vo\" class=\"hvx-link\" target=\"_blank\"\u003eManufacturer Page — CH-RES24-230VO\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"hvx-desc-card\"\u003e\n\u003ch2 class=\"hvx-section-title\"\u003eImportant\u003c\/h2\u003e\n\u003cp style=\"margin: 0; font-size: 14px; color: var(--hvx-slate);\"\u003eProfessional installation is recommended. Confirm electrical requirements, line sizes, maximum line length, and ambient operating limits before installation.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"hvx-desc-card\"\u003e\n\u003ch2 class=\"hvx-section-title\"\u003eFAQs\u003c\/h2\u003e\n\u003cdetails open=\"\" class=\"hvx-faq\"\u003e\n\u003csummary\u003eWhat line sizes does this system use?\u003c\/summary\u003e\n\u003cdiv style=\"margin-top: 8px;\"\u003e3\/8\" liquid and 5\/8\" gas.\u003c\/div\u003e\n\u003c\/details\u003e\n\u003cdetails open=\"\" class=\"hvx-faq\"\u003e\n\u003csummary\u003eIs the Smart Kit included?\u003c\/summary\u003e\n\u003cdiv style=\"margin-top: 8px;\"\u003eYes. Smart Kit app control is included, along with the remote control.\u003c\/div\u003e\n\u003c\/details\u003e\n\u003cdetails open=\"\" class=\"hvx-faq\"\u003e\n\u003csummary\u003eWhat is the outdoor heating and cooling ambient range?\u003c\/summary\u003e\n\u003cdiv style=\"margin-top: 8px;\"\u003eCooling: −13–122°F. Heating: −13–75°F.\u003c\/div\u003e\n\u003c\/details\u003e\n\u003cdetails open=\"\" class=\"hvx-faq\"\u003e\n\u003csummary\u003eWhat comfort features are included?\u003c\/summary\u003e\n\u003cdiv style=\"margin-top: 8px;\"\u003eAuto-Swing horizontal louvers, Turbo Mode, Follow Me mode, Timer On\/Off, Sleep Mode, and 46° Freeze Protection.\u003c\/div\u003e\n\u003c\/details\u003e\n\u003cdetails open=\"\" class=\"hvx-faq\"\u003e\n\u003csummary\u003eWhat controls are supported?\u003c\/summary\u003e\n\u003cdiv style=\"margin-top: 8px;\"\u003eIncluded remote control and Smart Kit app control; wall thermostat optional (sold separately).\u003c\/div\u003e\n\u003c\/details\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e","brand":"Cooper\u0026Hunter","offers":[{"title":"No installation","offer_id":42675387433003,"sku":"CH-R24MOLVWM-230VI + CH-RES24-230VO","price":1968.0,"currency_code":"USD","in_stock":true},{"title":"16FT","offer_id":42675387465771,"sku":"CH-R24MOLVWM-230VI + CH-RES24-230VO","price":2184.0,"currency_code":"USD","in_stock":true},{"title":"25FT","offer_id":42675387498539,"sku":"CH-R24MOLVWM-230VI + CH-RES24-230VO","price":2314.0,"currency_code":"USD","in_stock":true},{"title":"50FT","offer_id":42675387531307,"sku":"CH-R24MOLVWM-230VI + CH-RES24-230VO","price":2621.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0625\/5647\/1339\/files\/36k230v_16a9455a-6937-4bc9-8fb1-956232357d10.png?v=1769199738"},{"product_id":"cooper-hunter-30-000-btu-olivia-single-zone-wall-mount-minisplit-heat-pump-system-r454b-230v","title":"Cooper\u0026Hunter 30,000 BTU Olivia Single Zone Wall Mount Minisplit Heat Pump System R454B 230V","description":"\u003cstyle\u003e\n  :root{\n    --hvx-golden:#FAA819;\n    --hvx-slate:#262626;\n    --hvx-ivory:#F4F1E6;\n    --hvx-border:#e2e0d5;\n    --hvx-card-bg:#ffffff;\n  }\n\n  .hvx-desc{\n    font-family:\"Articulat CF\",system-ui,-apple-system,BlinkMacSystemFont,\"Segoe UI\",sans-serif;\n    color:var(--hvx-slate);\n    line-height:1.6;\n    background:var(--hvx-ivory);\n    padding:18px 18px 20px;\n    border-radius:16px;\n  }\n\n  .hvx-desc-header{\n    border-radius:14px;\n    padding:14px 16px;\n    background:linear-gradient(120deg,var(--hvx-golden),var(--hvx-slate));\n    color:#fff;\n    margin:0 0 16px;\n    box-shadow:0 10px 24px rgba(0,0,0,.22);\n    display:flex;\n    align-items:flex-start;\n    gap:12px;\n    flex-wrap:wrap;\n  }\n\n  .hvx-header-text{display:flex;flex-direction:column;gap:6px;min-width:260px}\n  .hvx-eyebrow{\n    font-size:11px;\n    letter-spacing:.14em;\n    text-transform:uppercase;\n    opacity:.9;\n  }\n  .hvx-title{\n    margin:0;\n    font-family:\"Anton\",\"Impact\",system-ui,-apple-system,BlinkMacSystemFont,\"Segoe UI\",sans-serif;\n    font-size:22px;\n    line-height:1.15;\n  }\n  .hvx-subtitle{margin:0;font-size:14px;opacity:.95}\n\n  .hvx-desc-card{\n    border:1px solid var(--hvx-border);\n    border-radius:14px;\n    background:var(--hvx-card-bg);\n    padding:16px 18px 18px;\n    box-shadow:0 4px 12px rgba(0,0,0,.06);\n    margin:14px 0;\n  }\n\n  .hvx-section-title{\n    margin:0 0 10px;\n    font-family:\"Anton\",\"Impact\",system-ui,-apple-system,BlinkMacSystemFont,\"Segoe UI\",sans-serif;\n    font-size:17px;\n    letter-spacing:.08em;\n    text-transform:uppercase;\n    color:var(--hvx-slate);\n    display:inline-flex;\n    align-items:center;\n    gap:8px;\n  }\n  .hvx-section-title::after{\n    content:\"\";\n    flex:1;\n    height:2px;\n    border-radius:999px;\n    background:linear-gradient(90deg,var(--hvx-golden),transparent);\n    opacity:.9;\n  }\n\n  .hvx-cta{display:flex;flex-wrap:wrap;gap:10px;margin:10px 0 0}\n  .hvx-cta a{\n    display:inline-flex;\n    align-items:center;\n    gap:8px;\n    padding:10px 14px;\n    border-radius:12px;\n    border:1px solid var(--hvx-border);\n    background:#fff;\n    text-decoration:none;\n    color:var(--hvx-slate);\n    font-size:14px;\n    font-weight:700;\n  }\n  .hvx-cta a.primary{\n    background:var(--hvx-slate);\n    color:#fff;\n    border-color:transparent;\n  }\n\n  .hvx-badges{display:flex;flex-wrap:wrap;gap:8px;margin:10px 0 0}\n  .hvx-badge{\n    font-size:12px;\n    border:1px solid var(--hvx-border);\n    border-radius:999px;\n    padding:6px 10px;\n    background:#fff;\n    white-space:nowrap;\n  }\n\n  .hvx-kv{\n    display:grid;\n    grid-template-columns:repeat(4,minmax(160px,1fr));\n    gap:10px;\n    margin-top:10px;\n  }\n  .hvx-kv \u003e div{\n    border:1px solid var(--hvx-border);\n    background:#fff;\n    border-radius:12px;\n    padding:10px 12px;\n    text-align:center;\n  }\n  .hvx-kv strong{display:block}\n\n  .hvx-table{\n    width:100%;\n    border-collapse:collapse;\n    min-width:520px;\n    background:#fff;\n    border:1px solid var(--hvx-border);\n    border-radius:12px;\n    overflow:hidden;\n  }\n  .hvx-table th,.hvx-table td{\n    border-bottom:1px solid var(--hvx-border);\n    padding:10px 12px;\n    vertical-align:top;\n    font-size:14px;\n  }\n  .hvx-table th{ text-align:left; font-weight:800; background:#fff; }\n  .hvx-table tr:nth-child(even) td{ background:#fbfaf6; }\n  .hvx-table tr:last-child td{ border-bottom:none; }\n  .hvx-table-wrap{ overflow:auto; border-radius:12px; }\n\n  .hvx-link{color:var(--hvx-slate); text-decoration:underline; text-underline-offset:2px}\n  .hvx-link:hover{opacity:.85}\n\n  details.hvx-faq{\n    border:1px solid var(--hvx-border);\n    background:#fff;\n    border-radius:12px;\n    padding:10px 12px;\n    margin:8px 0;\n  }\n  details.hvx-faq summary{cursor:pointer;font-weight:800}\n\n  @media(max-width:980px){\n    .hvx-kv{grid-template-columns:repeat(2,minmax(160px,1fr))}\n  }\n  @media(max-width:768px){\n    .hvx-desc{padding:14px 12px 16px;border-radius:12px}\n    .hvx-desc-header{padding:12px;border-radius:12px}\n    .hvx-title{font-size:19px}\n    .hvx-desc-card{padding:14px;margin:10px 0}\n  }\n\u003c\/style\u003e\n\u003cdiv class=\"hvx-desc\"\u003e\n\u003cdiv class=\"hvx-desc-header\"\u003e\n\u003cdiv class=\"hvx-header-text\"\u003e\n\u003cdiv class=\"hvx-eyebrow\"\u003eCooper\u0026amp;Hunter Olivia • R454B • Inverter\u003c\/div\u003e\n\u003ch1 class=\"hvx-title\"\u003eCooper\u0026amp;Hunter 30,000 BTU Olivia Single Zone Wall Mount Mini Split Heat Pump System R454B 230V\u003c\/h1\u003e\n\u003cp class=\"hvx-subtitle\"\u003e\u003cstrong\u003eSKU:\u003c\/strong\u003e CH-R30MELVWM-230VI + CH-REL30-230VO\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv aria-label=\"Contact options\" class=\"hvx-cta\"\u003e\n\u003ca title=\"Contact Us\" rel=\"noopener\" href=\"https:\/\/hvacsupplies.com\/pages\/contact\" class=\"primary\" target=\"_blank\"\u003e CLICK HERE TO CONTACT US FOR CUSTOM QUOTES AND QUESTIONS \u003c\/a\u003e \u003ca title=\"Call Us Now!\" href=\"tel:+18005438933\"\u003e CLICK TO CALL US 800-543-8933 FOR ANY QUESTIONS \u003c\/a\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"hvx-desc-card\"\u003e\n\u003ch2 class=\"hvx-section-title\"\u003eOverview\u003c\/h2\u003e\n\u003cp style=\"margin: 0;\"\u003eEnhance your home’s climate control with the Cooper\u0026amp;Hunter \u003cstrong\u003e30K BTU Olivia\u003c\/strong\u003e wall-mounted mini split heat pump system, utilizing the new \u003cstrong\u003eR454B refrigerant\u003c\/strong\u003e for environmentally friendly operation and efficient inverter performance. Designed for \u003cstrong\u003e208–230V\u003c\/strong\u003e applications, Olivia provides powerful, dependable heating and cooling for larger residential spaces with quiet performance and precise temperature regulation.\u003c\/p\u003e\n\u003cp style=\"margin: 10px 0 0;\"\u003eAdvanced comfort features include \u003cstrong\u003eAuto-Swing\u003c\/strong\u003e horizontal louvers for thorough air circulation, \u003cstrong\u003eTurbo Mode\u003c\/strong\u003e for rapid heating\/cooling, and \u003cstrong\u003eFollow Me\u003c\/strong\u003e comfort control using remote-sensed temperature. The included \u003cstrong\u003eSmart Kit\u003c\/strong\u003e enables app connectivity via the C\u0026amp;H mobile experience. Additional technologies include a \u003cstrong\u003e12Hz\u003c\/strong\u003e low compressor speed for quiet efficiency, \u003cstrong\u003eHigh-Frequency Racer Technology\u003c\/strong\u003e for rapid startup response, an \u003cstrong\u003eelectronic expansion valve\u003c\/strong\u003e for optimized refrigerant management, and an \u003cstrong\u003eintelligent dusting switch\u003c\/strong\u003e that reverses the fan to help clear dust, sand, and debris from the coil. Built with high-quality \u003cstrong\u003eTU1 copper tubes\u003c\/strong\u003e, Olivia is engineered for durability and efficient heat transfer, with added protection such as \u003cstrong\u003e46° Freeze Protection\u003c\/strong\u003e.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"hvx-desc-card\"\u003e\n\u003ch2 class=\"hvx-section-title\"\u003eHighlights\u003c\/h2\u003e\n\u003cdiv role=\"list\" class=\"hvx-badges\"\u003e\n\u003cspan role=\"listitem\" class=\"hvx-badge\"\u003e30,000 BTU class\u003c\/span\u003e \u003cspan role=\"listitem\" class=\"hvx-badge\"\u003eR454B refrigerant\u003c\/span\u003e \u003cspan role=\"listitem\" class=\"hvx-badge\"\u003eUp to 22.3 SEER2\u003c\/span\u003e \u003cspan role=\"listitem\" class=\"hvx-badge\"\u003eSmart Kit included\u003c\/span\u003e \u003cspan role=\"listitem\" class=\"hvx-badge\"\u003eAuto-swing (horizontal louvers)\u003c\/span\u003e \u003cspan role=\"listitem\" class=\"hvx-badge\"\u003e12Hz low-speed operation\u003c\/span\u003e \u003cspan role=\"listitem\" class=\"hvx-badge\"\u003eTurbo Mode\u003c\/span\u003e \u003cspan role=\"listitem\" class=\"hvx-badge\"\u003e46° Freeze Protection\u003c\/span\u003e \u003cspan role=\"listitem\" class=\"hvx-badge\"\u003e208–230V, 1Ph, 60Hz\u003c\/span\u003e\n\u003c\/div\u003e\n\u003cul style=\"margin: 12px 0 0; padding-left: 18px;\"\u003e\n\u003cli\u003e\n\u003cstrong\u003ePrecision comfort:\u003c\/strong\u003e inverter-driven output adapts to demand for improved temperature control and efficiency.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFast response comfort:\u003c\/strong\u003e High-Frequency Racer Technology targets rapid temperature control at startup.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOptimized refrigerant flow:\u003c\/strong\u003e electronic expansion valve (EEV) supports stable operation across changing conditions.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCleaner operation:\u003c\/strong\u003e intelligent dusting switch helps clear dust, sand, and debris from the coil.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eControl options:\u003c\/strong\u003e Smart Kit with app control, included remote control, wall thermostat optional (sold separately).\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cdiv aria-label=\"At-a-glance\" role=\"list\" class=\"hvx-kv\"\u003e\n\u003cdiv role=\"listitem\"\u003e\n\u003cstrong\u003eIndoor\u003c\/strong\u003eCH-R30MELVWM-230VI\u003c\/div\u003e\n\u003cdiv role=\"listitem\"\u003e\n\u003cstrong\u003eOutdoor\u003c\/strong\u003eCH-REL30-230VO\u003c\/div\u003e\n\u003cdiv role=\"listitem\"\u003e\n\u003cstrong\u003eLines\u003c\/strong\u003e3\/8\" liquid · 5\/8\" gas\u003c\/div\u003e\n\u003cdiv role=\"listitem\"\u003e\n\u003cstrong\u003eMax run\u003c\/strong\u003e164 ft\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"hvx-desc-card\"\u003e\n\u003ch2 class=\"hvx-section-title\"\u003eWhat’s Included\u003c\/h2\u003e\n\u003cul style=\"padding-left: 18px; margin: 8px 0;\"\u003e\n\u003cli\u003eIndoor unit: CH-R30MELVWM-230VI\u003c\/li\u003e\n\u003cli\u003eOutdoor unit: CH-REL30-230VO (Single-Zone)\u003c\/li\u003e\n\u003cli\u003eRemote control (included)\u003c\/li\u003e\n\u003cli\u003eSmart Kit (included) for app control\u003c\/li\u003e\n\u003cli\u003eManufacturer documentation (see Documents \u0026amp; Downloads)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"hvx-desc-card\"\u003e\n\u003ch2 class=\"hvx-section-title\"\u003eIndoor Specs\u003c\/h2\u003e\n\u003cdiv class=\"hvx-table-wrap\"\u003e\n\u003ctable aria-label=\"Indoor unit specifications\" class=\"hvx-table\"\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eSpec\u003c\/th\u003e\n\u003cth\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCH-R30MELVWM-230VI\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSystem type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSingle Zone\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRefrigerant type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eR454B\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBTU rated\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e30,000\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower source\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e208–230V, 1Ph, 60Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eVoltage range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e187–253 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSEER2\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e22.3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEER2\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e12\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRefrigerant piping (liq\/gas)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3\/8\" \/ 5\/8\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMinimum circuit ampacity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMax fuse\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e15\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIndoor noise level (H\/M\/L)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e52 \/ 45 \/ 36 dB(A)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIndoor air flow\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e871.1 \/ 647.5 \/ 447.3 \/ 329.6 CFM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDehumidification\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e7.61 pnt\/day\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eUnit dimensions (W×H×D)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e49.57 × 11.14 × 14.25 in\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNet \/ Gross weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e43.43 \/ 56.88 lb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePacking dimensions (W×D×H)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e52.76 × 17.72 × 15.16 in\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDrain pipe diameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e5\/8\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating range (Cooling)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e60–90°F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating range (Heating)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e32–86°F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eController\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eRemote controller\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"hvx-desc-card\"\u003e\n\u003ch2 class=\"hvx-section-title\"\u003eOutdoor Specs\u003c\/h2\u003e\n\u003cdiv class=\"hvx-table-wrap\"\u003e\n\u003ctable aria-label=\"Outdoor unit specifications\" class=\"hvx-table\"\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eSpec\u003c\/th\u003e\n\u003cth\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCH-REL30-230VO\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRefrigerant type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eR454B\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBTU rated\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e30,000\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower source\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e208–230V, 1Ph, 60Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eVoltage range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e187–253 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRefrigerant piping (liq\/gas)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3\/8\" \/ 5\/8\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMax pipe length\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e164 ft\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMax height difference (IDU↔ODU)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e82 ft\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCooling capacity (Min\/Max)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e30,000 (6,500–32,800) BTU\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eHeating capacity (Min\/Max)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e30,000 (12,600–31,400) BTU\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eHSPF2-5\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e7.2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eHSPF2-4\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e9.5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCOP\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3.08\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDehumidification\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e8.45 pnt\/day\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOutdoor noise level\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e61 dB(A)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOutdoor air flow\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2,235.3 CFM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMinimum circuit ampacity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e28\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMax fuse\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e30\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAmbient temp (Heating)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e−13–75°F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAmbient temp (Cooling)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e−13–122°F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eUnit dimensions (W×H×D)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e37.24 × 16.14 × 31.89 in\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNet \/ Gross weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e142.86 \/ 154.54 lb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePacking dimensions (W×D×H)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e42.91 × 19.68 × 34.84 in\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRefrigerant precharge\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e25\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAdditional charge (3\/8\" liquid)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.32\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"hvx-desc-card\"\u003e\n\u003ch2 class=\"hvx-section-title\"\u003eDocuments \u0026amp; Downloads\u003c\/h2\u003e\n\u003cul style=\"padding-left: 18px; margin: 8px 0;\"\u003e\n\u003cli\u003e\u003ca rel=\"noopener\" href=\"https:\/\/media.cooperandhunter.us\/4731\/CH-REL30-230VO_CH-R30MELVWM-230VI.pdf\" class=\"hvx-link\" target=\"_blank\"\u003eSubmittal (PDF) — CH-REL30-230VO + CH-R30MELVWM-230VI\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca rel=\"noopener\" href=\"https:\/\/media.cooperandhunter.us\/4161\/CH-REL30-230VO-%2B-CH-PRO30MASTWM-230VI.pdf\" class=\"hvx-link\" target=\"_blank\"\u003eSubmittal (PDF) — CH-REL30-230VO + CH-PRO30MASTWM-230VI\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca rel=\"noopener\" href=\"https:\/\/media.cooperandhunter.us\/4175\/CH-REL30-230VO-%2B-CH-RH30MASTWM-230VI.pdf\" class=\"hvx-link\" target=\"_blank\"\u003eSubmittal (PDF) — CH-REL30-230VO + CH-RH30MASTWM-230VI\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca rel=\"noopener\" href=\"https:\/\/media.cooperandhunter.us\/4118\/Installation-Manual-R454B-Outdoor-units--.pdf\" class=\"hvx-link\" target=\"_blank\"\u003eInstallation Manual (PDF) — R454B Outdoor Units\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca rel=\"noopener\" href=\"https:\/\/www.ahridirectory.org\/NewSearch?programId=41\u0026amp;searchTypeId=3\u0026amp;productTypeId=4\" class=\"hvx-link\" target=\"_blank\"\u003eAHRI Directory Listing — AHRI #207742340\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca rel=\"noopener\" href=\"https:\/\/cooperandhunter.us\/product\/ch-r30melvwm-230vi\" class=\"hvx-link\" target=\"_blank\"\u003eManufacturer Page — CH-R30MELVWM-230VI\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca rel=\"noopener\" href=\"https:\/\/cooperandhunter.us\/product\/ch-rel30-230vo\" class=\"hvx-link\" target=\"_blank\"\u003eManufacturer Page — CH-REL30-230VO\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"hvx-desc-card\"\u003e\n\u003ch2 class=\"hvx-section-title\"\u003eVideos\u003c\/h2\u003e\n\u003cp style=\"margin: 0 0 8px;\"\u003e\u003cstrong\u003eMini-split installation videos\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul style=\"padding-left: 18px; margin: 0 0 10px;\"\u003e\n\u003cli\u003e\u003ca rel=\"noopener\" href=\"https:\/\/youtu.be\/hDEhQ94r2rQ\" class=\"hvx-link\" target=\"_blank\"\u003eHow to Install Mini Split Cooper\u0026amp;Hunter\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca rel=\"noopener\" href=\"https:\/\/youtu.be\/Cxuiytm_CMo\" class=\"hvx-link\" target=\"_blank\"\u003eHow to Install Multi Zone Mini Split System (Cooper\u0026amp;Hunter) 2020\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca rel=\"noopener\" href=\"https:\/\/youtu.be\/JQkth-AM5CE\" class=\"hvx-link\" target=\"_blank\"\u003eFull Installation of Mini Split Ductless Unit, Step by Step!\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp style=\"margin: 0 0 8px;\"\u003e\u003cstrong\u003eHow To \u0026amp; Instructional Videos\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul style=\"padding-left: 18px; margin: 0 0 10px;\"\u003e\n\u003cli\u003e\u003ca rel=\"noopener\" href=\"https:\/\/youtu.be\/dTJjaVCAIsg\" class=\"hvx-link\" target=\"_blank\"\u003eHow to Clean Cooper\u0026amp;Hunter Mini Split Wall Mount A\/C\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca rel=\"noopener\" href=\"https:\/\/youtu.be\/7mzwevkxw20\" class=\"hvx-link\" target=\"_blank\"\u003eTop Tips from Cooper\u0026amp;Hunter Mini Split User Manual\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca rel=\"noopener\" href=\"https:\/\/youtu.be\/kqezdpVRkiY\" class=\"hvx-link\" target=\"_blank\"\u003eMini Split WiFi Set Up (Cooper\u0026amp;Hunter)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca rel=\"noopener\" href=\"https:\/\/youtu.be\/Z7jhBvW4uw8\" class=\"hvx-link\" target=\"_blank\"\u003eCooper\u0026amp;Hunter New Remote Control (2022)\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp style=\"margin: 0 0 8px;\"\u003e\u003cstrong\u003eProducts overview\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul style=\"padding-left: 18px; margin: 0;\"\u003e\n\u003cli\u003e\u003ca rel=\"noopener\" href=\"https:\/\/youtu.be\/0kUh03W9qS8\" class=\"hvx-link\" target=\"_blank\"\u003eCooper\u0026amp;Hunter: Multi Zone AC for the Home\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca rel=\"noopener\" href=\"https:\/\/youtu.be\/TCcju8Ii6L8\" class=\"hvx-link\" target=\"_blank\"\u003eMulti-Zone Mini-Split System vs Central A\/C in Home (2019) Cooper\u0026amp;Hunter\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca rel=\"noopener\" href=\"https:\/\/youtu.be\/qCWu8HCNl3Q\" class=\"hvx-link\" target=\"_blank\"\u003eMini Split Indoor Unit Types Explained\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca rel=\"noopener\" href=\"https:\/\/youtu.be\/kEOAxTfwV4Y?si=_BgztZ7_0l3fj2lZ\" class=\"hvx-link\" target=\"_blank\"\u003eCooper\u0026amp;Hunter Olivia Series\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"hvx-desc-card\"\u003e\n\u003ch2 class=\"hvx-section-title\"\u003eImportant\u003c\/h2\u003e\n\u003cp style=\"margin: 0; font-size: 14px; color: var(--hvx-slate);\"\u003eProfessional installation is recommended. Confirm electrical requirements, line sizes, maximum line length, and ambient operating limits before installation.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"hvx-desc-card\"\u003e\n\u003ch2 class=\"hvx-section-title\"\u003eFAQs\u003c\/h2\u003e\n\u003cdetails open=\"\" class=\"hvx-faq\"\u003e\n\u003csummary\u003eWhat line sizes does this system use?\u003c\/summary\u003e\n\u003cdiv style=\"margin-top: 8px;\"\u003e3\/8\" liquid and 5\/8\" gas.\u003c\/div\u003e\n\u003c\/details\u003e\n\u003cdetails open=\"\" class=\"hvx-faq\"\u003e\n\u003csummary\u003eWhat is the max line length and height difference?\u003c\/summary\u003e\n\u003cdiv style=\"margin-top: 8px;\"\u003eMaximum line length is 164 ft and maximum height difference is 82 ft.\u003c\/div\u003e\n\u003c\/details\u003e\n\u003cdetails open=\"\" class=\"hvx-faq\"\u003e\n\u003csummary\u003eIs the Smart Kit included?\u003c\/summary\u003e\n\u003cdiv style=\"margin-top: 8px;\"\u003eSmart Kit app control is supported; included remote controller is provided for standard operation.\u003c\/div\u003e\n\u003c\/details\u003e\n\u003cdetails open=\"\" class=\"hvx-faq\"\u003e\n\u003csummary\u003eWhat is the outdoor heating and cooling ambient range?\u003c\/summary\u003e\n\u003cdiv style=\"margin-top: 8px;\"\u003eCooling: −13–122°F. Heating: −13–75°F.\u003c\/div\u003e\n\u003c\/details\u003e\n\u003cdetails open=\"\" class=\"hvx-faq\"\u003e\n\u003csummary\u003eWhat controls are supported?\u003c\/summary\u003e\n\u003cdiv style=\"margin-top: 8px;\"\u003eSmart Kit app control, included remote control; wall thermostat optional (sold separately).\u003c\/div\u003e\n\u003c\/details\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e","brand":"Cooper\u0026Hunter","offers":[{"title":"No installation","offer_id":42675400278059,"sku":"CH-R30MELVWM-230VI + CH-REL30-230VO","price":2313.0,"currency_code":"USD","in_stock":true},{"title":"16FT","offer_id":42675400310827,"sku":"CH-R30MELVWM-230VI + CH-REL30-230VO","price":2529.0,"currency_code":"USD","in_stock":true},{"title":"25FT","offer_id":42675400343595,"sku":"CH-R30MELVWM-230VI + CH-REL30-230VO","price":2658.0,"currency_code":"USD","in_stock":true},{"title":"50FT","offer_id":42675400376363,"sku":"CH-R30MELVWM-230VI + CH-REL30-230VO","price":2965.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0625\/5647\/1339\/files\/36k230v_16a9455a-6937-4bc9-8fb1-956232357d10.png?v=1769199738"},{"product_id":"cooper-hunter-36-000-btu-olivia-single-zone-wall-mount-minisplit-heat-pump-system-r454b-230v","title":"Cooper\u0026Hunter 36,000 BTU Olivia Single Zone Wall Mount Minisplit Heat Pump System R454B 230V","description":"\u003cstyle\u003e\n  :root{\n    --hvx-golden:#FAA819;\n    --hvx-slate:#262626;\n    --hvx-ivory:#F4F1E6;\n    --hvx-border:#e2e0d5;\n    --hvx-card-bg:#ffffff;\n  }\n\n  .hvx-desc{\n    font-family:\"Articulat CF\",system-ui,-apple-system,BlinkMacSystemFont,\"Segoe UI\",sans-serif;\n    color:var(--hvx-slate);\n    line-height:1.6;\n    background:var(--hvx-ivory);\n    padding:18px 18px 20px;\n    border-radius:16px;\n  }\n\n  .hvx-desc-header{\n    border-radius:14px;\n    padding:14px 16px;\n    background:linear-gradient(120deg,var(--hvx-golden),var(--hvx-slate));\n    color:#fff;\n    margin:0 0 16px;\n    box-shadow:0 10px 24px rgba(0,0,0,.22);\n    display:flex;\n    align-items:flex-start;\n    gap:12px;\n    flex-wrap:wrap;\n  }\n\n  .hvx-header-text{display:flex;flex-direction:column;gap:6px;min-width:260px}\n  .hvx-eyebrow{\n    font-size:11px;\n    letter-spacing:.14em;\n    text-transform:uppercase;\n    opacity:.9;\n  }\n  .hvx-title{\n    margin:0;\n    font-family:\"Anton\",\"Impact\",system-ui,-apple-system,BlinkMacSystemFont,\"Segoe UI\",sans-serif;\n    font-size:22px;\n    line-height:1.15;\n  }\n  .hvx-subtitle{margin:0;font-size:14px;opacity:.95}\n\n  .hvx-desc-card{\n    border:1px solid var(--hvx-border);\n    border-radius:14px;\n    background:var(--hvx-card-bg);\n    padding:16px 18px 18px;\n    box-shadow:0 4px 12px rgba(0,0,0,.06);\n    margin:14px 0;\n  }\n\n  .hvx-section-title{\n    margin:0 0 10px;\n    font-family:\"Anton\",\"Impact\",system-ui,-apple-system,BlinkMacSystemFont,\"Segoe UI\",sans-serif;\n    font-size:17px;\n    letter-spacing:.08em;\n    text-transform:uppercase;\n    color:var(--hvx-slate);\n    display:inline-flex;\n    align-items:center;\n    gap:8px;\n  }\n  .hvx-section-title::after{\n    content:\"\";\n    flex:1;\n    height:2px;\n    border-radius:999px;\n    background:linear-gradient(90deg,var(--hvx-golden),transparent);\n    opacity:.9;\n  }\n\n  .hvx-cta{display:flex;flex-wrap:wrap;gap:10px;margin:10px 0 0}\n  .hvx-cta a{\n    display:inline-flex;\n    align-items:center;\n    gap:8px;\n    padding:10px 14px;\n    border-radius:12px;\n    border:1px solid var(--hvx-border);\n    background:#fff;\n    text-decoration:none;\n    color:var(--hvx-slate);\n    font-size:14px;\n    font-weight:700;\n  }\n  .hvx-cta a.primary{\n    background:var(--hvx-slate);\n    color:#fff;\n    border-color:transparent;\n  }\n\n  .hvx-badges{display:flex;flex-wrap:wrap;gap:8px;margin:10px 0 0}\n  .hvx-badge{\n    font-size:12px;\n    border:1px solid var(--hvx-border);\n    border-radius:999px;\n    padding:6px 10px;\n    background:#fff;\n    white-space:nowrap;\n  }\n\n  .hvx-kv{\n    display:grid;\n    grid-template-columns:repeat(4,minmax(160px,1fr));\n    gap:10px;\n    margin-top:10px;\n  }\n  .hvx-kv \u003e div{\n    border:1px solid var(--hvx-border);\n    background:#fff;\n    border-radius:12px;\n    padding:10px 12px;\n    text-align:center;\n  }\n  .hvx-kv strong{display:block}\n\n  .hvx-table{\n    width:100%;\n    border-collapse:collapse;\n    min-width:520px;\n    background:#fff;\n    border:1px solid var(--hvx-border);\n    border-radius:12px;\n    overflow:hidden;\n  }\n  .hvx-table th,.hvx-table td{\n    border-bottom:1px solid var(--hvx-border);\n    padding:10px 12px;\n    vertical-align:top;\n    font-size:14px;\n  }\n  .hvx-table th{ text-align:left; font-weight:800; background:#fff; }\n  .hvx-table tr:nth-child(even) td{ background:#fbfaf6; }\n  .hvx-table tr:last-child td{ border-bottom:none; }\n  .hvx-table-wrap{ overflow:auto; border-radius:12px; }\n\n  .hvx-link{color:var(--hvx-slate); text-decoration:underline; text-underline-offset:2px}\n  .hvx-link:hover{opacity:.85}\n\n  details.hvx-faq{\n    border:1px solid var(--hvx-border);\n    background:#fff;\n    border-radius:12px;\n    padding:10px 12px;\n    margin:8px 0;\n  }\n  details.hvx-faq summary{cursor:pointer;font-weight:800}\n\n  @media(max-width:980px){\n    .hvx-kv{grid-template-columns:repeat(2,minmax(160px,1fr))}\n  }\n  @media(max-width:768px){\n    .hvx-desc{padding:14px 12px 16px;border-radius:12px}\n    .hvx-desc-header{padding:12px;border-radius:12px}\n    .hvx-title{font-size:19px}\n    .hvx-desc-card{padding:14px;margin:10px 0}\n  }\n\u003c\/style\u003e\n\u003cdiv class=\"hvx-desc\"\u003e\n\u003cdiv class=\"hvx-desc-header\"\u003e\n\u003cdiv class=\"hvx-header-text\"\u003e\n\u003cdiv class=\"hvx-eyebrow\"\u003eCooper\u0026amp;Hunter Olivia • R454B • Inverter\u003c\/div\u003e\n\u003ch1 class=\"hvx-title\"\u003eCooper\u0026amp;Hunter 36,000 BTU Olivia Single Zone Wall Mount Mini Split Heat Pump System R454B 230V\u003c\/h1\u003e\n\u003cp class=\"hvx-subtitle\"\u003e\u003cstrong\u003eSKU:\u003c\/strong\u003e CH-R36MELVWM-230VI + CH-REL36-230VO\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv aria-label=\"Contact options\" class=\"hvx-cta\"\u003e\n\u003ca title=\"Contact Us\" rel=\"noopener\" href=\"https:\/\/hvacsupplies.com\/pages\/contact\" class=\"primary\" target=\"_blank\"\u003e CLICK HERE TO CONTACT US FOR CUSTOM QUOTES AND QUESTIONS \u003c\/a\u003e \u003ca title=\"Call Us Now!\" href=\"tel:+18005438933\"\u003e CLICK TO CALL US 800-543-8933 FOR ANY QUESTIONS \u003c\/a\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"hvx-desc-card\"\u003e\n\u003ch2 class=\"hvx-section-title\"\u003eOverview\u003c\/h2\u003e\n\u003cp style=\"margin: 0;\"\u003eEnhance your home’s climate control with the Cooper\u0026amp;Hunter \u003cstrong\u003e36K BTU Olivia\u003c\/strong\u003e wall-mounted mini split heat pump system, utilizing the new \u003cstrong\u003eR454B refrigerant\u003c\/strong\u003e for environmentally friendly operation and efficient inverter performance. Designed for \u003cstrong\u003e208–230V\u003c\/strong\u003e applications, Olivia provides powerful heating and cooling for large residential spaces with smooth output control and quiet operation.\u003c\/p\u003e\n\u003cp style=\"margin: 10px 0 0;\"\u003eAdvanced comfort features include \u003cstrong\u003eAuto-Swing\u003c\/strong\u003e horizontal louvers for thorough air circulation, \u003cstrong\u003eTurbo Mode\u003c\/strong\u003e for rapid heating\/cooling, and \u003cstrong\u003eFollow Me\u003c\/strong\u003e comfort control using remote-sensed temperature. The Olivia Mini Split includes a \u003cstrong\u003eSmart Kit\u003c\/strong\u003e for app connectivity via the C\u0026amp;H experience. Additional technologies include a \u003cstrong\u003e12Hz\u003c\/strong\u003e low compressor speed for quiet efficiency, \u003cstrong\u003eHigh-Frequency Racer Technology\u003c\/strong\u003e for rapid startup response, an \u003cstrong\u003eelectronic expansion valve\u003c\/strong\u003e for optimized refrigerant management, and an \u003cstrong\u003eintelligent dusting switch\u003c\/strong\u003e that reverses the fan to help clear dust, sand, and debris from the coil. Built with high-quality \u003cstrong\u003eTU1 copper tubes\u003c\/strong\u003e, Olivia is engineered for durability and efficient heat transfer, with added protection such as \u003cstrong\u003e46° Freeze Protection\u003c\/strong\u003e.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"hvx-desc-card\"\u003e\n\u003ch2 class=\"hvx-section-title\"\u003eHighlights\u003c\/h2\u003e\n\u003cdiv role=\"list\" class=\"hvx-badges\"\u003e\n\u003cspan role=\"listitem\" class=\"hvx-badge\"\u003e36,000 BTU class\u003c\/span\u003e \u003cspan role=\"listitem\" class=\"hvx-badge\"\u003eR454B refrigerant\u003c\/span\u003e \u003cspan role=\"listitem\" class=\"hvx-badge\"\u003eUp to 19.5 SEER2\u003c\/span\u003e \u003cspan role=\"listitem\" class=\"hvx-badge\"\u003eSmart Kit included\u003c\/span\u003e \u003cspan role=\"listitem\" class=\"hvx-badge\"\u003eAuto-swing (horizontal louvers)\u003c\/span\u003e \u003cspan role=\"listitem\" class=\"hvx-badge\"\u003e12Hz low-speed operation\u003c\/span\u003e \u003cspan role=\"listitem\" class=\"hvx-badge\"\u003eTurbo Mode\u003c\/span\u003e \u003cspan role=\"listitem\" class=\"hvx-badge\"\u003e46° Freeze Protection\u003c\/span\u003e \u003cspan role=\"listitem\" class=\"hvx-badge\"\u003e208–230V, 1Ph, 60Hz\u003c\/span\u003e\n\u003c\/div\u003e\n\u003cul style=\"margin: 12px 0 0; padding-left: 18px;\"\u003e\n\u003cli\u003e\n\u003cstrong\u003eInverter efficiency:\u003c\/strong\u003e dynamically adjusts output to demand for improved comfort and lower energy usage.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFast response comfort:\u003c\/strong\u003e High-Frequency Racer Technology targets rapid temperature control at startup.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOptimized refrigerant flow:\u003c\/strong\u003e electronic expansion valve (EEV) supports stable operation across changing conditions.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCleaner operation:\u003c\/strong\u003e intelligent dusting switch helps clear dust, sand, and debris from the coil.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eControl options:\u003c\/strong\u003e Smart Kit with app control, included remote control, wall thermostat optional (sold separately).\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cdiv aria-label=\"At-a-glance\" role=\"list\" class=\"hvx-kv\"\u003e\n\u003cdiv role=\"listitem\"\u003e\n\u003cstrong\u003eIndoor\u003c\/strong\u003eCH-R36MELVWM-230VI\u003c\/div\u003e\n\u003cdiv role=\"listitem\"\u003e\n\u003cstrong\u003eOutdoor\u003c\/strong\u003eCH-REL36-230VO\u003c\/div\u003e\n\u003cdiv role=\"listitem\"\u003e\n\u003cstrong\u003eLines\u003c\/strong\u003e3\/8\" liquid · 5\/8\" gas\u003c\/div\u003e\n\u003cdiv role=\"listitem\"\u003e\n\u003cstrong\u003eMax run\u003c\/strong\u003e213.2 ft\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"hvx-desc-card\"\u003e\n\u003ch2 class=\"hvx-section-title\"\u003eWhat’s Included\u003c\/h2\u003e\n\u003cul style=\"padding-left: 18px; margin: 8px 0;\"\u003e\n\u003cli\u003eIndoor unit: CH-R36MELVWM-230VI\u003c\/li\u003e\n\u003cli\u003eOutdoor unit: CH-REL36-230VO (Single-Zone)\u003c\/li\u003e\n\u003cli\u003eRemote control (included)\u003c\/li\u003e\n\u003cli\u003eSmart Kit for app control\u003c\/li\u003e\n\u003cli\u003eManufacturer documentation (see Documents \u0026amp; Downloads)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"hvx-desc-card\"\u003e\n\u003ch2 class=\"hvx-section-title\"\u003eIndoor Specs\u003c\/h2\u003e\n\u003cdiv class=\"hvx-table-wrap\"\u003e\n\u003ctable aria-label=\"Indoor unit specifications\" class=\"hvx-table\"\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eSpec\u003c\/th\u003e\n\u003cth\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCH-R36MELVWM-230VI\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSystem type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSingle Zone\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRefrigerant type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eR454B\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBTU rated\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e36,000\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower source\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e208–230V, 1Ph, 60Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eVoltage range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e187–253 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSEER2\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e19.5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEER2\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e9.3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRefrigerant piping (liq\/gas)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3\/8\" \/ 5\/8\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMinimum circuit ampacity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMax fuse\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e15\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIndoor noise level (H\/M\/L)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e51 \/ 45 \/ 33.5 dB(A)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIndoor air flow\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e871.1 \/ 676.9 \/ 447.3 \/ 329.6 CFM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDehumidification\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e10.78 pnt\/day\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eUnit dimensions (W×H×D)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e49.57 × 11.14 × 14.25 in\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNet \/ Gross weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e43.43 \/ 56.88 lb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePacking dimensions (W×D×H)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e52.76 × 17.72 × 15.16 in\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDrain pipe diameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e5\/8\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating range (Cooling)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e60–90°F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating range (Heating)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e32–86°F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eController\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eRemote controller\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"hvx-desc-card\"\u003e\n\u003ch2 class=\"hvx-section-title\"\u003eOutdoor Specs\u003c\/h2\u003e\n\u003cdiv class=\"hvx-table-wrap\"\u003e\n\u003ctable aria-label=\"Outdoor unit specifications\" class=\"hvx-table\"\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eSpec\u003c\/th\u003e\n\u003cth\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCH-REL36-230VO\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRefrigerant type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eR454B\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBTU rated\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e36,000\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower source\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e208–230V, 1Ph, 60Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eVoltage range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e187–253 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRefrigerant piping (liq\/gas)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3\/8\" \/ 5\/8\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMax pipe length\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e213.2 ft\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMax height difference (IDU↔ODU)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e98.4 ft\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCooling capacity (Min\/Max)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e36,000 (6,600–36,800) BTU\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eHeating capacity (Min\/Max)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e36,000 (11,400–44,000) BTU\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eHSPF2-5\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e7\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eHSPF2-4\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e9.1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCOP\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2.95\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDehumidification\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e10.78 pnt\/day\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOutdoor noise level\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e63 dB(A)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOutdoor air flow\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2,235.3 CFM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMinimum circuit ampacity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e33\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMax fuse\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e35\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAmbient temp (Heating)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e−13–75°F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAmbient temp (Cooling)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e−13–122°F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eUnit dimensions (W×H×D)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e37.24 × 16.14 × 31.89 in\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNet \/ Gross weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e150.35 \/ 160.27 lb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePacking dimensions (W×D×H)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e42.91 × 19.68 × 34.84 in\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRefrigerant precharge\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e25\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAdditional charge (3\/8\" liquid)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.32\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"hvx-desc-card\"\u003e\n\u003ch2 class=\"hvx-section-title\"\u003eDocuments \u0026amp; Downloads\u003c\/h2\u003e\n\u003cul style=\"padding-left: 18px; margin: 8px 0;\"\u003e\n\u003cli\u003e\u003ca rel=\"noopener\" href=\"https:\/\/media.cooperandhunter.us\/4732\/CH-REL36-230VO_CH-R36MELVWM-230VI.pdf\" class=\"hvx-link\" target=\"_blank\"\u003eSubmittal (PDF) — CH-REL36-230VO + CH-R36MELVWM-230VI\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca rel=\"noopener\" href=\"https:\/\/media.cooperandhunter.us\/4163\/CH-REL36-230VO-%2B-CH-PRO36MASTWM-230VI.pdf\" class=\"hvx-link\" target=\"_blank\"\u003eSubmittal (PDF) — CH-REL36-230VO + CH-PRO36MASTWM-230VI\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca rel=\"noopener\" href=\"https:\/\/media.cooperandhunter.us\/4177\/CH-REL36-230VO-%2B-CH-RH36MASTWM-230VI.pdf\" class=\"hvx-link\" target=\"_blank\"\u003eSubmittal (PDF) — CH-REL36-230VO + CH-RH36MASTWM-230VI\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca rel=\"noopener\" href=\"https:\/\/media.cooperandhunter.us\/4118\/Installation-Manual-R454B-Outdoor-units--.pdf\" class=\"hvx-link\" target=\"_blank\"\u003eInstallation Manual (PDF) — R454B Outdoor Units\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca rel=\"noopener\" href=\"https:\/\/www.ahridirectory.org\/NewSearch?programId=41\u0026amp;searchTypeId=3\u0026amp;productTypeId=4\" class=\"hvx-link\" target=\"_blank\"\u003eAHRI Directory Listing — AHRI #207742340\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca rel=\"noopener\" href=\"https:\/\/cooperandhunter.us\/product\/ch-r36melvwm-230vi\" class=\"hvx-link\" target=\"_blank\"\u003eManufacturer Page — CH-R36MELVWM-230VI\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca rel=\"noopener\" href=\"https:\/\/cooperandhunter.us\/product\/ch-rel36-230vo\" class=\"hvx-link\" target=\"_blank\"\u003eManufacturer Page — CH-REL36-230VO\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"hvx-desc-card\"\u003e\n\u003ch2 class=\"hvx-section-title\"\u003eVideos\u003c\/h2\u003e\n\u003cp style=\"margin: 0 0 8px;\"\u003e\u003cstrong\u003eMini-split installation videos\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul style=\"padding-left: 18px; margin: 0 0 10px;\"\u003e\n\u003cli\u003e\u003ca rel=\"noopener\" href=\"https:\/\/youtu.be\/hDEhQ94r2rQ\" class=\"hvx-link\" target=\"_blank\"\u003eHow to Install Mini Split Cooper\u0026amp;Hunter\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca rel=\"noopener\" href=\"https:\/\/youtu.be\/Cxuiytm_CMo\" class=\"hvx-link\" target=\"_blank\"\u003eHow to Install Multi Zone Mini Split System (Cooper\u0026amp;Hunter) 2020\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca rel=\"noopener\" href=\"https:\/\/youtu.be\/JQkth-AM5CE\" class=\"hvx-link\" target=\"_blank\"\u003eFull Installation of Mini Split Ductless Unit, Step by Step!\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp style=\"margin: 0 0 8px;\"\u003e\u003cstrong\u003eHow To \u0026amp; Instructional Videos\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul style=\"padding-left: 18px; margin: 0 0 10px;\"\u003e\n\u003cli\u003e\u003ca rel=\"noopener\" href=\"https:\/\/youtu.be\/dTJjaVCAIsg\" class=\"hvx-link\" target=\"_blank\"\u003eHow to Clean Cooper\u0026amp;Hunter Mini Split Wall Mount A\/C\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca rel=\"noopener\" href=\"https:\/\/youtu.be\/7mzwevkxw20\" class=\"hvx-link\" target=\"_blank\"\u003eTop Tips from Cooper\u0026amp;Hunter Mini Split User Manual\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca rel=\"noopener\" href=\"https:\/\/youtu.be\/kqezdpVRkiY\" class=\"hvx-link\" target=\"_blank\"\u003eMini Split WiFi Set Up (Cooper\u0026amp;Hunter)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca rel=\"noopener\" href=\"https:\/\/youtu.be\/Z7jhBvW4uw8\" class=\"hvx-link\" target=\"_blank\"\u003eCooper\u0026amp;Hunter New Remote Control (2022)\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp style=\"margin: 0 0 8px;\"\u003e\u003cstrong\u003eProducts overview\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul style=\"padding-left: 18px; margin: 0;\"\u003e\n\u003cli\u003e\u003ca rel=\"noopener\" href=\"https:\/\/youtu.be\/0kUh03W9qS8\" class=\"hvx-link\" target=\"_blank\"\u003eCooper\u0026amp;Hunter: Multi Zone AC for the Home\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca rel=\"noopener\" href=\"https:\/\/youtu.be\/TCcju8Ii6L8\" class=\"hvx-link\" target=\"_blank\"\u003eMulti-Zone Mini-Split System vs Central A\/C in Home (2019) Cooper\u0026amp;Hunter\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca rel=\"noopener\" href=\"https:\/\/youtu.be\/qCWu8HCNl3Q\" class=\"hvx-link\" target=\"_blank\"\u003eMini Split Indoor Unit Types Explained\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca rel=\"noopener\" href=\"https:\/\/youtu.be\/kEOAxTfwV4Y?si=_BgztZ7_0l3fj2lZ\" class=\"hvx-link\" target=\"_blank\"\u003eCooper\u0026amp;Hunter Olivia Series\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"hvx-desc-card\"\u003e\n\u003ch2 class=\"hvx-section-title\"\u003eImportant\u003c\/h2\u003e\n\u003cp style=\"margin: 0; font-size: 14px; color: var(--hvx-slate);\"\u003eProfessional installation is recommended. Confirm electrical requirements, line sizes, maximum line length, and ambient operating limits before installation.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"hvx-desc-card\"\u003e\n\u003ch2 class=\"hvx-section-title\"\u003eFAQs\u003c\/h2\u003e\n\u003cdetails open=\"\" class=\"hvx-faq\"\u003e\n\u003csummary\u003eWhat line sizes does this system use?\u003c\/summary\u003e\n\u003cdiv style=\"margin-top: 8px;\"\u003e3\/8\" liquid and 5\/8\" gas.\u003c\/div\u003e\n\u003c\/details\u003e\n\u003cdetails open=\"\" class=\"hvx-faq\"\u003e\n\u003csummary\u003eWhat is the max line length and height difference?\u003c\/summary\u003e\n\u003cdiv style=\"margin-top: 8px;\"\u003eMaximum line length is 213.2 ft and maximum height difference is 98.4 ft.\u003c\/div\u003e\n\u003c\/details\u003e\n\u003cdetails open=\"\" class=\"hvx-faq\"\u003e\n\u003csummary\u003eWhat is the outdoor heating and cooling ambient range?\u003c\/summary\u003e\n\u003cdiv style=\"margin-top: 8px;\"\u003eCooling: −13–122°F. Heating: −13–75°F.\u003c\/div\u003e\n\u003c\/details\u003e\n\u003cdetails open=\"\" class=\"hvx-faq\"\u003e\n\u003csummary\u003eWhat controls are supported?\u003c\/summary\u003e\n\u003cdiv style=\"margin-top: 8px;\"\u003eSmart Kit app control, included remote control; wall thermostat optional (sold separately).\u003c\/div\u003e\n\u003c\/details\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e","brand":"Cooper\u0026Hunter","offers":[{"title":"No installation","offer_id":42675421249579,"sku":"CH-R36MELVWM-230VI + CH-REL36-230VO","price":2559.0,"currency_code":"USD","in_stock":true},{"title":"16FT","offer_id":42675421282347,"sku":"CH-R36MELVWM-230VI + CH-REL36-230VO","price":2775.0,"currency_code":"USD","in_stock":true},{"title":"25FT","offer_id":42675421315115,"sku":"CH-R36MELVWM-230VI + CH-REL36-230VO","price":2904.0,"currency_code":"USD","in_stock":true},{"title":"50FT","offer_id":42675421347883,"sku":"CH-R36MELVWM-230VI + CH-REL36-230VO","price":3211.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0625\/5647\/1339\/files\/36k230v_16a9455a-6937-4bc9-8fb1-956232357d10.png?v=1769199738"},{"product_id":"cooper-hunter-9-000-btu-olivia-midnight-hyper-single-zone-wall-mount-minisplit-heat-pump-system-r454b-230v","title":"Cooper\u0026Hunter 9,000 BTU Olivia Midnight Hyper Single Zone Wall Mount Minisplit Heat Pump System R454B 230V","description":"\u003cstyle\u003e\n  :root{\n    --hvx-golden:#FAA819;\n    --hvx-slate:#262626;\n    --hvx-ivory:#F4F1E6;\n    --hvx-border:#e2e0d5;\n    --hvx-card-bg:#ffffff;\n  }\n\n  .hvx-desc{\n    font-family:\"Articulat CF\",system-ui,-apple-system,BlinkMacSystemFont,\"Segoe UI\",sans-serif;\n    color:var(--hvx-slate);\n    line-height:1.6;\n    background:var(--hvx-ivory);\n    padding:18px 18px 20px;\n    border-radius:16px;\n  }\n\n  .hvx-desc-header{\n    border-radius:14px;\n    padding:14px 16px;\n    background:linear-gradient(120deg,var(--hvx-golden),var(--hvx-slate));\n    color:#fff;\n    margin:0 0 16px;\n    box-shadow:0 10px 24px rgba(0,0,0,.22);\n    display:flex;\n    align-items:flex-start;\n    gap:12px;\n    flex-wrap:wrap;\n  }\n\n  .hvx-header-text{display:flex;flex-direction:column;gap:6px;min-width:260px}\n  .hvx-eyebrow{\n    font-size:11px;\n    letter-spacing:.14em;\n    text-transform:uppercase;\n    opacity:.9;\n  }\n  .hvx-title{\n    margin:0;\n    font-family:\"Anton\",\"Impact\",system-ui,-apple-system,BlinkMacSystemFont,\"Segoe UI\",sans-serif;\n    font-size:22px;\n    line-height:1.15;\n  }\n  .hvx-subtitle{margin:0;font-size:14px;opacity:.95}\n\n  .hvx-desc-card{\n    border:1px solid var(--hvx-border);\n    border-radius:14px;\n    background:var(--hvx-card-bg);\n    padding:16px 18px 18px;\n    box-shadow:0 4px 12px rgba(0,0,0,.06);\n    margin:14px 0;\n  }\n\n  .hvx-section-title{\n    margin:0 0 10px;\n    font-family:\"Anton\",\"Impact\",system-ui,-apple-system,BlinkMacSystemFont,\"Segoe UI\",sans-serif;\n    font-size:17px;\n    letter-spacing:.08em;\n    text-transform:uppercase;\n    color:var(--hvx-slate);\n    display:inline-flex;\n    align-items:center;\n    gap:8px;\n  }\n  .hvx-section-title::after{\n    content:\"\";\n    flex:1;\n    height:2px;\n    border-radius:999px;\n    background:linear-gradient(90deg,var(--hvx-golden),transparent);\n    opacity:.9;\n  }\n\n  .hvx-cta{display:flex;flex-wrap:wrap;gap:10px;margin:10px 0 0}\n  .hvx-cta a{\n    display:inline-flex;\n    align-items:center;\n    gap:8px;\n    padding:10px 14px;\n    border-radius:12px;\n    border:1px solid var(--hvx-border);\n    background:#fff;\n    text-decoration:none;\n    color:var(--hvx-slate);\n    font-size:14px;\n    font-weight:700;\n  }\n  .hvx-cta a.primary{\n    background:var(--hvx-slate);\n    color:#fff;\n    border-color:transparent;\n  }\n\n  .hvx-badges{display:flex;flex-wrap:wrap;gap:8px;margin:10px 0 0}\n  .hvx-badge{\n    font-size:12px;\n    border:1px solid var(--hvx-border);\n    border-radius:999px;\n    padding:6px 10px;\n    background:#fff;\n    white-space:nowrap;\n  }\n\n  .hvx-kv{\n    display:grid;\n    grid-template-columns:repeat(4,minmax(160px,1fr));\n    gap:10px;\n    margin-top:10px;\n  }\n  .hvx-kv \u003e div{\n    border:1px solid var(--hvx-border);\n    background:#fff;\n    border-radius:12px;\n    padding:10px 12px;\n    text-align:center;\n  }\n  .hvx-kv strong{display:block}\n\n  .hvx-table{\n    width:100%;\n    border-collapse:collapse;\n    min-width:520px;\n    background:#fff;\n    border:1px solid var(--hvx-border);\n    border-radius:12px;\n    overflow:hidden;\n  }\n  .hvx-table th,.hvx-table td{\n    border-bottom:1px solid var(--hvx-border);\n    padding:10px 12px;\n    vertical-align:top;\n    font-size:14px;\n  }\n  .hvx-table th{ text-align:left; font-weight:800; background:#fff; }\n  .hvx-table tr:nth-child(even) td{ background:#fbfaf6; }\n  .hvx-table tr:last-child td{ border-bottom:none; }\n  .hvx-table-wrap{ overflow:auto; border-radius:12px; }\n\n  .hvx-link{color:var(--hvx-slate); text-decoration:underline; text-underline-offset:2px}\n  .hvx-link:hover{opacity:.85}\n\n  details.hvx-faq{\n    border:1px solid var(--hvx-border);\n    background:#fff;\n    border-radius:12px;\n    padding:10px 12px;\n    margin:8px 0;\n  }\n  details.hvx-faq summary{cursor:pointer;font-weight:800}\n\n  @media(max-width:980px){\n    .hvx-kv{grid-template-columns:repeat(2,minmax(160px,1fr))}\n  }\n  @media(max-width:768px){\n    .hvx-desc{padding:14px 12px 16px;border-radius:12px}\n    .hvx-desc-header{padding:12px;border-radius:12px}\n    .hvx-title{font-size:19px}\n    .hvx-desc-card{padding:14px;margin:10px 0}\n  }\n\u003c\/style\u003e\n\u003cdiv class=\"hvx-desc\"\u003e\n\u003cdiv class=\"hvx-desc-header\"\u003e\n\u003cdiv class=\"hvx-header-text\"\u003e\n\u003cdiv class=\"hvx-eyebrow\"\u003eCooper\u0026amp;Hunter Olivia Midnight • Black • R454B • Hyper Heat\u003c\/div\u003e\n\u003ch1 class=\"hvx-title\"\u003eCooper\u0026amp;Hunter 9,000 BTU Olivia Midnight Single Zone Wall Mount Mini Split Heat Pump System R454B 230V\u003c\/h1\u003e\n\u003cp class=\"hvx-subtitle\"\u003e\u003cstrong\u003eSKU:\u003c\/strong\u003e CH-RB09MOLVWM-230VI + CH-RHP09-230VO\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv aria-label=\"Contact options\" class=\"hvx-cta\"\u003e\n\u003ca title=\"Contact Us\" rel=\"noopener\" href=\"https:\/\/hvacsupplies.com\/pages\/contact\" class=\"primary\" target=\"_blank\"\u003e CLICK HERE TO CONTACT US FOR CUSTOM QUOTES AND QUESTIONS \u003c\/a\u003e \u003ca title=\"Call Us Now!\" href=\"tel:+18005438933\"\u003e CLICK TO CALL US 800-543-8933 FOR ANY QUESTIONS \u003c\/a\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"hvx-desc-card\"\u003e\n\u003ch2 class=\"hvx-section-title\"\u003eOverview\u003c\/h2\u003e\n\u003cp style=\"margin: 0;\"\u003eTransform your home’s climate control with the Cooper\u0026amp;Hunter \u003cstrong\u003e9K BTU Olivia Midnight\u003c\/strong\u003e wall-mounted mini split heat pump system, featuring the new \u003cstrong\u003eR454B refrigerant\u003c\/strong\u003e and a sleek \u003cstrong\u003eblack\u003c\/strong\u003e indoor unit for a modern, premium look. Designed for \u003cstrong\u003e208–230V\u003c\/strong\u003e applications, Olivia Midnight delivers efficient comfort with advanced inverter performance and up to \u003cstrong\u003e26.4 SEER2\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp style=\"margin: 10px 0 0;\"\u003eComfort features include \u003cstrong\u003eAuto-Swing\u003c\/strong\u003e horizontal louvers for even air circulation, \u003cstrong\u003eTurbo Mode\u003c\/strong\u003e for rapid heating\/cooling, and \u003cstrong\u003eFollow Me\u003c\/strong\u003e temperature sensing from the remote. The system includes a \u003cstrong\u003eSmart Kit\u003c\/strong\u003e for app connectivity. Additional technologies include \u003cstrong\u003e12Hz\u003c\/strong\u003e ultra-low compressor speed for quiet efficiency, \u003cstrong\u003eHigh-Frequency Racer Technology\u003c\/strong\u003e for rapid startup response, an \u003cstrong\u003eelectronic expansion valve\u003c\/strong\u003e for optimized refrigerant management, and an \u003cstrong\u003eintelligent dusting switch\u003c\/strong\u003e that reverses the fan to help clear dust, sand, and debris from the coil. Built with \u003cstrong\u003eTU1 copper tubes\u003c\/strong\u003e, Olivia Midnight is engineered for durability and efficient heat transfer, with added protection including \u003cstrong\u003e46° Freeze Protection\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp style=\"margin: 10px 0 0;\"\u003eThe included \u003cstrong\u003eHyper Heating\u003c\/strong\u003e outdoor unit is rated for heating operation down to \u003cstrong\u003e−22°F\u003c\/strong\u003e.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"hvx-desc-card\"\u003e\n\u003ch2 class=\"hvx-section-title\"\u003eHighlights\u003c\/h2\u003e\n\u003cdiv role=\"list\" class=\"hvx-badges\"\u003e\n\u003cspan role=\"listitem\" class=\"hvx-badge\"\u003e9,000 BTU class\u003c\/span\u003e \u003cspan role=\"listitem\" class=\"hvx-badge\"\u003eOlivia Midnight (Black indoor)\u003c\/span\u003e \u003cspan role=\"listitem\" class=\"hvx-badge\"\u003eR454B refrigerant\u003c\/span\u003e \u003cspan role=\"listitem\" class=\"hvx-badge\"\u003eSEER2 26.4\u003c\/span\u003e \u003cspan role=\"listitem\" class=\"hvx-badge\"\u003eEER2 15.8\u003c\/span\u003e \u003cspan role=\"listitem\" class=\"hvx-badge\"\u003eHyper Heat to −22°F (Outdoor)\u003c\/span\u003e \u003cspan role=\"listitem\" class=\"hvx-badge\"\u003eSmart Kit included\u003c\/span\u003e \u003cspan role=\"listitem\" class=\"hvx-badge\"\u003eAuto-swing (horizontal louvers)\u003c\/span\u003e \u003cspan role=\"listitem\" class=\"hvx-badge\"\u003e208–230V, 1Ph, 60Hz\u003c\/span\u003e\n\u003c\/div\u003e\n\u003cul style=\"margin: 12px 0 0; padding-left: 18px;\"\u003e\n\u003cli\u003e\n\u003cstrong\u003eCold-climate heating:\u003c\/strong\u003e Hyper Heating outdoor unit rated for heating operation down to −22°F.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQuiet efficiency:\u003c\/strong\u003e 12Hz ultra-low compressor speed supports smooth, efficient operation.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFast comfort:\u003c\/strong\u003e High-Frequency Racer Technology targets rapid temperature control at startup.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOptimized refrigerant control:\u003c\/strong\u003e electronic expansion valve (EEV) helps manage refrigerant flow precisely.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eControl options:\u003c\/strong\u003e Smart Kit app control, included remote control; wall thermostat optional (sold separately).\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cdiv aria-label=\"At-a-glance\" role=\"list\" class=\"hvx-kv\"\u003e\n\u003cdiv role=\"listitem\"\u003e\n\u003cstrong\u003eIndoor\u003c\/strong\u003eCH-RB09MOLVWM-230VI\u003c\/div\u003e\n\u003cdiv role=\"listitem\"\u003e\n\u003cstrong\u003eOutdoor\u003c\/strong\u003eCH-RHP09-230VO\u003c\/div\u003e\n\u003cdiv role=\"listitem\"\u003e\n\u003cstrong\u003eLines\u003c\/strong\u003e1\/4\" liquid · 3\/8\" gas\u003c\/div\u003e\n\u003cdiv role=\"listitem\"\u003e\n\u003cstrong\u003eMax run\u003c\/strong\u003e82 ft\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"hvx-desc-card\"\u003e\n\u003ch2 class=\"hvx-section-title\"\u003eWhat’s Included\u003c\/h2\u003e\n\u003cul style=\"padding-left: 18px; margin: 8px 0;\"\u003e\n\u003cli\u003eIndoor unit: CH-RB09MOLVWM-230VI (Olivia Midnight Black)\u003c\/li\u003e\n\u003cli\u003eOutdoor unit: CH-RHP09-230VO (Hyper Heating)\u003c\/li\u003e\n\u003cli\u003eRemote control (included)\u003c\/li\u003e\n\u003cli\u003eSmart Kit for app control\u003c\/li\u003e\n\u003cli\u003eManufacturer documentation (see Documents \u0026amp; Downloads)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"hvx-desc-card\"\u003e\n\u003ch2 class=\"hvx-section-title\"\u003eIndoor Specs\u003c\/h2\u003e\n\u003cdiv class=\"hvx-table-wrap\"\u003e\n\u003ctable aria-label=\"Indoor unit specifications\" class=\"hvx-table\"\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eSpec\u003c\/th\u003e\n\u003cth\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCH-RB09MOLVWM-230VI\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSystem type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSingle \/ Multi-zone capable indoor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRefrigerant type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eR454B\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated capacity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e9,000 BTU\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower source\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e208\/230V, 1Ph, 60Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSEER2\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e26.4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEER2\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e15.8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMinimum circuit ampacity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMax fuse\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e15 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRefrigerant piping (liq\/gas)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1\/4\" \/ 3\/8\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIndoor air flow (Turbo\/Hi\/Mi\/Lo\/Si)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e382.6 \/ 294.3 \/ 194.2 \/ 153.0 \/ N\/A CFM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIndoor air flow\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e341.18 \/ 291.18 \/ 194.12 \/ 152.94 CFM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIndoor noise (Turbo\/Hi\/Mi\/Lo\/Si)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e45.5 \/ 42 \/ 36 \/ 21 \/ 19.5 dB(A)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIndoor noise level (H\/M\/L)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e40 \/ 34 \/ 23.5 dB(A)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eUnit dimensions (W×H×D)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e31.57 × 11.61 × 7.87 in\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePacking dimensions (W×D×H)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e34.45 × 11.22 × 14.96 in\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNet \/ Gross weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e18.96 \/ 24.25 lb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDrainage water pipe diameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e5\/8\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating range (Cooling)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e60–90°F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating range (Heating)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e32–86°F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"hvx-desc-card\"\u003e\n\u003ch2 class=\"hvx-section-title\"\u003eOutdoor Specs\u003c\/h2\u003e\n\u003cdiv class=\"hvx-table-wrap\"\u003e\n\u003ctable aria-label=\"Outdoor unit specifications\" class=\"hvx-table\"\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eSpec\u003c\/th\u003e\n\u003cth\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCH-RHP09-230VO\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSystem type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSingle-zone unit (Hyper Heating)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRefrigerant type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eR454B\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBTU rated\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e9,000\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower source\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e208–230V, 1Ph, 60Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eVoltage range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e187–253 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRefrigerant piping (liq\/gas)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1\/4\" \/ 3\/8\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMax pipe length\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e82 ft\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMax height difference (IDU↔ODU)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e49.2 ft\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCooling capacity (Min\/Max)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e9,000 (3,800–13,500) BTU\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eHeating capacity (Min\/Max)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e12,000 (3,800–16,000) BTU\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eHSPF2-5\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e9.5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eHSPF2-4\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e12.5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCOP\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3.76\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDehumidification\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.63 pnt\/day\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOutdoor noise level\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e56 dB(A)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOutdoor air flow\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1,470.6 CFM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMinimum circuit ampacity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e15\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMax fuse\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e15\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAmbient temp (Heating)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e−22–75°F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAmbient temp (Cooling)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e−22–122°F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eUnit dimensions (W×H×D)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e31.69 × 12.99 × 21.81 in\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNet \/ Gross weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e72.75 \/ 78.70 lb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePacking dimensions (W×D×H)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e36.02 × 14.57 × 24.21 in\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRefrigerant precharge\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e25\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAdditional charge (1\/4\" liquid)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.16\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"hvx-desc-card\"\u003e\n\u003ch2 class=\"hvx-section-title\"\u003eDocuments \u0026amp; Downloads\u003c\/h2\u003e\n\u003cul style=\"padding-left: 18px; margin: 8px 0;\"\u003e\n\u003cli\u003e\u003ca rel=\"noopener\" href=\"https:\/\/media.cooperandhunter.us\/4952\/CH-RES09-230VO-_-CH-RB09MOLVWM-230VI.pdf\" class=\"hvx-link\" target=\"_blank\"\u003eSubmittal (PDF) — CH-RES09-230VO + CH-RB09MOLVWM-230VI\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca rel=\"noopener\" href=\"https:\/\/media.cooperandhunter.us\/4958\/CH-RHP09-230VO_CH-RB09MOLVWM-230VI.pdf\" class=\"hvx-link\" target=\"_blank\"\u003eSubmittal (PDF) — CH-RHP09-230VO + CH-RB09MOLVWM-230VI\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca rel=\"noopener\" href=\"https:\/\/media.cooperandhunter.us\/4962\/CH-RB09MOLVWM-230VI.pdf\" class=\"hvx-link\" target=\"_blank\"\u003eSubmittal (PDF) — CH-RB09MOLVWM-230VI\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca rel=\"noopener\" href=\"https:\/\/media.cooperandhunter.us\/4155\/CH-RHP09-230VO-%2B-CH-PRO09MASTWM-230VI.pdf\" class=\"hvx-link\" target=\"_blank\"\u003eSubmittal (PDF) — CH-RHP09-230VO + CH-PRO09MASTWM-230VI\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca rel=\"noopener\" href=\"https:\/\/media.cooperandhunter.us\/4168\/CH-RHP09-230VO-%2B-CH-RH09MASTWM-230VI.pdf\" class=\"hvx-link\" target=\"_blank\"\u003eSubmittal (PDF) — CH-RHP09-230VO + CH-RH09MASTWM-230VI\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca rel=\"noopener\" href=\"https:\/\/media.cooperandhunter.us\/4202\/CH-RHP09-230VO-%2B-CH-RS06-12MDT--MS.pdf\" class=\"hvx-link\" target=\"_blank\"\u003eSubmittal (PDF) — CH-RHP09-230VO + CH-RS06-12MDT (MS)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca rel=\"noopener\" href=\"https:\/\/media.cooperandhunter.us\/4683\/CH-RHP09-230VO_CH-RSH09MCT.pdf\" class=\"hvx-link\" target=\"_blank\"\u003eSubmittal (PDF) — CH-RHP09-230VO + CH-RSH09MCT\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca rel=\"noopener\" href=\"https:\/\/media.cooperandhunter.us\/4682\/CH-RHP09-230VO_CH-RH09MCT.pdf\" class=\"hvx-link\" target=\"_blank\"\u003eSubmittal (PDF) — CH-RHP09-230VO + CH-RH09MCT\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca rel=\"noopener\" href=\"https:\/\/media.cooperandhunter.us\/4118\/Installation-Manual-R454B-Outdoor-units--.pdf\" class=\"hvx-link\" target=\"_blank\"\u003eInstallation Manual (PDF) — R454B Outdoor Units\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca rel=\"noopener\" href=\"https:\/\/media.cooperandhunter.us\/4200\/SlimDuct-Leaflet-R454B.pdf\" class=\"hvx-link\" target=\"_blank\"\u003eSlimDuct Leaflet (PDF) — R454B\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca rel=\"noopener\" href=\"https:\/\/www.ahridirectory.org\" class=\"hvx-link\" target=\"_blank\"\u003eAHRI Directory Listing — AHRI #207742320\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca rel=\"noopener\" href=\"https:\/\/cooperandhunter.us\/product\/ch-rhp09-230vo\" class=\"hvx-link\" target=\"_blank\"\u003eManufacturer Page — CH-RHP09-230VO\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"hvx-desc-card\"\u003e\n\u003ch2 class=\"hvx-section-title\"\u003eImportant\u003c\/h2\u003e\n\u003cp style=\"margin: 0; font-size: 14px; color: var(--hvx-slate);\"\u003eProfessional installation is recommended. Confirm electrical requirements, line sizes, maximum line length, and ambient operating limits before installation.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"hvx-desc-card\"\u003e\n\u003ch2 class=\"hvx-section-title\"\u003eFAQs\u003c\/h2\u003e\n\u003cdetails open=\"\" class=\"hvx-faq\"\u003e\n\u003csummary\u003eIs this system “Hyper Heat”?\u003c\/summary\u003e\n\u003cdiv style=\"margin-top: 8px;\"\u003eYes. The CH-RHP09-230VO outdoor unit is a Hyper Heating model rated to operate in heating down to −22°F.\u003c\/div\u003e\n\u003c\/details\u003e\n\u003cdetails open=\"\" class=\"hvx-faq\"\u003e\n\u003csummary\u003eWhat line sizes does this system use?\u003c\/summary\u003e\n\u003cdiv style=\"margin-top: 8px;\"\u003e1\/4\" liquid and 3\/8\" gas.\u003c\/div\u003e\n\u003c\/details\u003e\n\u003cdetails open=\"\" class=\"hvx-faq\"\u003e\n\u003csummary\u003eWhat is the max line length and height difference?\u003c\/summary\u003e\n\u003cdiv style=\"margin-top: 8px;\"\u003eMaximum line length is 82 ft and maximum height difference is 49.2 ft.\u003c\/div\u003e\n\u003c\/details\u003e\n\u003cdetails open=\"\" class=\"hvx-faq\"\u003e\n\u003csummary\u003eWhat is the outdoor heating and cooling ambient range?\u003c\/summary\u003e\n\u003cdiv style=\"margin-top: 8px;\"\u003eCooling: −22–122°F. Heating: −22–75°F.\u003c\/div\u003e\n\u003c\/details\u003e\n\u003cdetails open=\"\" class=\"hvx-faq\"\u003e\n\u003csummary\u003eWhat controls are supported?\u003c\/summary\u003e\n\u003cdiv style=\"margin-top: 8px;\"\u003eSmart Kit app control, included remote control; wall thermostat optional (sold separately).\u003c\/div\u003e\n\u003c\/details\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e","brand":"Cooper\u0026Hunter","offers":[{"title":"No installation","offer_id":42675426656299,"sku":"CH-RB09MOLVWM-230VI + CH-RHP09-230VO","price":1359.0,"currency_code":"USD","in_stock":true},{"title":"16FT","offer_id":42675426689067,"sku":"CH-RB09MOLVWM-230VI + CH-RHP09-230VO","price":1541.0,"currency_code":"USD","in_stock":true},{"title":"25FT","offer_id":42675426721835,"sku":"CH-RB09MOLVWM-230VI + CH-RHP09-230VO","price":1587.0,"currency_code":"USD","in_stock":true},{"title":"50FT","offer_id":42675426754603,"sku":"CH-RB09MOLVWM-230VI + CH-RHP09-230VO","price":1807.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0625\/5647\/1339\/files\/12_b44b24b4-03fa-4830-8afc-e22e19e71fbe.png?v=1769199597"},{"product_id":"cooper-hunter-12-000-btu-olivia-midnight-hyper-single-zone-wall-mount-minisplit-heat-pump-system-r454b-230v","title":"Cooper\u0026Hunter 12,000 BTU Olivia Midnight Hyper Single Zone Wall Mount Minisplit Heat Pump System R454B 230V","description":"\u003cstyle\u003e\n  :root{\n    --hvx-golden:#FAA819;\n    --hvx-slate:#262626;\n    --hvx-ivory:#F4F1E6;\n    --hvx-border:#e2e0d5;\n    --hvx-card-bg:#ffffff;\n  }\n\n  .hvx-desc{\n    font-family:\"Articulat CF\",system-ui,-apple-system,BlinkMacSystemFont,\"Segoe UI\",sans-serif;\n    color:var(--hvx-slate);\n    line-height:1.6;\n    background:var(--hvx-ivory);\n    padding:18px 18px 20px;\n    border-radius:16px;\n  }\n\n  .hvx-desc-header{\n    border-radius:14px;\n    padding:14px 16px;\n    background:linear-gradient(120deg,var(--hvx-golden),var(--hvx-slate));\n    color:#fff;\n    margin:0 0 16px;\n    box-shadow:0 10px 24px rgba(0,0,0,.22);\n    display:flex;\n    align-items:flex-start;\n    gap:12px;\n    flex-wrap:wrap;\n  }\n\n  .hvx-header-text{display:flex;flex-direction:column;gap:6px;min-width:260px}\n  .hvx-eyebrow{\n    font-size:11px;\n    letter-spacing:.14em;\n    text-transform:uppercase;\n    opacity:.9;\n  }\n  .hvx-title{\n    margin:0;\n    font-family:\"Anton\",\"Impact\",system-ui,-apple-system,BlinkMacSystemFont,\"Segoe UI\",sans-serif;\n    font-size:22px;\n    line-height:1.15;\n  }\n  .hvx-subtitle{margin:0;font-size:14px;opacity:.95}\n\n  .hvx-desc-card{\n    border:1px solid var(--hvx-border);\n    border-radius:14px;\n    background:var(--hvx-card-bg);\n    padding:16px 18px 18px;\n    box-shadow:0 4px 12px rgba(0,0,0,.06);\n    margin:14px 0;\n  }\n\n  .hvx-section-title{\n    margin:0 0 10px;\n    font-family:\"Anton\",\"Impact\",system-ui,-apple-system,BlinkMacSystemFont,\"Segoe UI\",sans-serif;\n    font-size:17px;\n    letter-spacing:.08em;\n    text-transform:uppercase;\n    color:var(--hvx-slate);\n    display:inline-flex;\n    align-items:center;\n    gap:8px;\n  }\n  .hvx-section-title::after{\n    content:\"\";\n    flex:1;\n    height:2px;\n    border-radius:999px;\n    background:linear-gradient(90deg,var(--hvx-golden),transparent);\n    opacity:.9;\n  }\n\n  .hvx-cta{display:flex;flex-wrap:wrap;gap:10px;margin:10px 0 0}\n  .hvx-cta a{\n    display:inline-flex;\n    align-items:center;\n    gap:8px;\n    padding:10px 14px;\n    border-radius:12px;\n    border:1px solid var(--hvx-border);\n    background:#fff;\n    text-decoration:none;\n    color:var(--hvx-slate);\n    font-size:14px;\n    font-weight:700;\n  }\n  .hvx-cta a.primary{\n    background:var(--hvx-slate);\n    color:#fff;\n    border-color:transparent;\n  }\n\n  .hvx-badges{display:flex;flex-wrap:wrap;gap:8px;margin:10px 0 0}\n  .hvx-badge{\n    font-size:12px;\n    border:1px solid var(--hvx-border);\n    border-radius:999px;\n    padding:6px 10px;\n    background:#fff;\n    white-space:nowrap;\n  }\n\n  .hvx-kv{\n    display:grid;\n    grid-template-columns:repeat(4,minmax(160px,1fr));\n    gap:10px;\n    margin-top:10px;\n  }\n  .hvx-kv \u003e div{\n    border:1px solid var(--hvx-border);\n    background:#fff;\n    border-radius:12px;\n    padding:10px 12px;\n    text-align:center;\n  }\n  .hvx-kv strong{display:block}\n\n  .hvx-table{\n    width:100%;\n    border-collapse:collapse;\n    min-width:520px;\n    background:#fff;\n    border:1px solid var(--hvx-border);\n    border-radius:12px;\n    overflow:hidden;\n  }\n  .hvx-table th,.hvx-table td{\n    border-bottom:1px solid var(--hvx-border);\n    padding:10px 12px;\n    vertical-align:top;\n    font-size:14px;\n  }\n  .hvx-table th{ text-align:left; font-weight:800; background:#fff; }\n  .hvx-table tr:nth-child(even) td{ background:#fbfaf6; }\n  .hvx-table tr:last-child td{ border-bottom:none; }\n  .hvx-table-wrap{ overflow:auto; border-radius:12px; }\n\n  .hvx-link{color:var(--hvx-slate); text-decoration:underline; text-underline-offset:2px}\n  .hvx-link:hover{opacity:.85}\n\n  details.hvx-faq{\n    border:1px solid var(--hvx-border);\n    background:#fff;\n    border-radius:12px;\n    padding:10px 12px;\n    margin:8px 0;\n  }\n  details.hvx-faq summary{cursor:pointer;font-weight:800}\n\n  @media(max-width:980px){\n    .hvx-kv{grid-template-columns:repeat(2,minmax(160px,1fr))}\n  }\n  @media(max-width:768px){\n    .hvx-desc{padding:14px 12px 16px;border-radius:12px}\n    .hvx-desc-header{padding:12px;border-radius:12px}\n    .hvx-title{font-size:19px}\n    .hvx-desc-card{padding:14px;margin:10px 0}\n  }\n\u003c\/style\u003e\n\u003cdiv class=\"hvx-desc\"\u003e\n\u003cdiv class=\"hvx-desc-header\"\u003e\n\u003cdiv class=\"hvx-header-text\"\u003e\n\u003cdiv class=\"hvx-eyebrow\"\u003eCooper\u0026amp;Hunter Olivia Midnight • Black • R454B • Hyper Heat\u003c\/div\u003e\n\u003ch1 class=\"hvx-title\"\u003eCooper\u0026amp;Hunter 12,000 BTU Olivia Midnight Single Zone Wall Mount Mini Split Heat Pump System R454B 230V\u003c\/h1\u003e\n\u003cp class=\"hvx-subtitle\"\u003e\u003cstrong\u003eSKU:\u003c\/strong\u003e CH-RB12MOLVWM-230VI + CH-RHP12-230VO\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv aria-label=\"Contact options\" class=\"hvx-cta\"\u003e\n\u003ca title=\"Contact Us\" rel=\"noopener\" href=\"https:\/\/hvacsupplies.com\/pages\/contact\" class=\"primary\" target=\"_blank\"\u003e CLICK HERE TO CONTACT US FOR CUSTOM QUOTES AND QUESTIONS \u003c\/a\u003e \u003ca title=\"Call Us Now!\" href=\"tel:+18005438933\"\u003e CLICK TO CALL US 800-543-8933 FOR ANY QUESTIONS \u003c\/a\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"hvx-desc-card\"\u003e\n\u003ch2 class=\"hvx-section-title\"\u003eOverview\u003c\/h2\u003e\n\u003cp style=\"margin: 0;\"\u003eTransform your home’s climate control with the Cooper\u0026amp;Hunter \u003cstrong\u003e12K BTU Olivia Midnight\u003c\/strong\u003e wall-mounted mini split system, featuring the new \u003cstrong\u003eR454B refrigerant\u003c\/strong\u003e and an elegant \u003cstrong\u003eblack\u003c\/strong\u003e indoor unit for contemporary style. Designed for \u003cstrong\u003e208–230V\u003c\/strong\u003e setups, Olivia Midnight delivers efficient comfort with up to \u003cstrong\u003e23.1 SEER2\u003c\/strong\u003e and advanced features built for convenience.\u003c\/p\u003e\n\u003cp style=\"margin: 10px 0 0;\"\u003eComfort features include \u003cstrong\u003eAuto-Swing\u003c\/strong\u003e horizontal louvers for even air circulation, \u003cstrong\u003eTurbo Mode\u003c\/strong\u003e for rapid heating\/cooling, \u003cstrong\u003eFollow Me\u003c\/strong\u003e sensing from the remote, \u003cstrong\u003e46° Freeze Protection\u003c\/strong\u003e, and a \u003cstrong\u003eSmart Kit\u003c\/strong\u003e for app connectivity via the C\u0026amp;H app. Additional technology includes \u003cstrong\u003e12Hz\u003c\/strong\u003e ultra-low compressor speed for quiet efficiency, \u003cstrong\u003eHigh-Frequency Racer Technology\u003c\/strong\u003e for rapid startup response, an \u003cstrong\u003eelectronic expansion valve\u003c\/strong\u003e for optimized refrigerant flow control, and an \u003cstrong\u003eintelligent dusting switch\u003c\/strong\u003e to help clear dust, sand, and debris from the coil. Built with \u003cstrong\u003eTU1 copper tubes\u003c\/strong\u003e for durability and efficient heat transfer.\u003c\/p\u003e\n\u003cp style=\"margin: 10px 0 0;\"\u003eThe included \u003cstrong\u003eHyper Heating\u003c\/strong\u003e outdoor unit is rated for heating operation down to \u003cstrong\u003e−22°F\u003c\/strong\u003e.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"hvx-desc-card\"\u003e\n\u003ch2 class=\"hvx-section-title\"\u003eHighlights\u003c\/h2\u003e\n\u003cdiv role=\"list\" class=\"hvx-badges\"\u003e\n\u003cspan role=\"listitem\" class=\"hvx-badge\"\u003e12,000 BTU class\u003c\/span\u003e \u003cspan role=\"listitem\" class=\"hvx-badge\"\u003eOlivia Midnight (Black indoor)\u003c\/span\u003e \u003cspan role=\"listitem\" class=\"hvx-badge\"\u003eR454B refrigerant\u003c\/span\u003e \u003cspan role=\"listitem\" class=\"hvx-badge\"\u003eSEER2 23.1\u003c\/span\u003e \u003cspan role=\"listitem\" class=\"hvx-badge\"\u003eEER2 13\u003c\/span\u003e \u003cspan role=\"listitem\" class=\"hvx-badge\"\u003eHyper Heat to −22°F (Outdoor)\u003c\/span\u003e \u003cspan role=\"listitem\" class=\"hvx-badge\"\u003eSmart Kit included\u003c\/span\u003e \u003cspan role=\"listitem\" class=\"hvx-badge\"\u003eAuto-swing (horizontal louvers)\u003c\/span\u003e \u003cspan role=\"listitem\" class=\"hvx-badge\"\u003e208–230V, 1Ph, 60Hz\u003c\/span\u003e \u003cspan role=\"listitem\" class=\"hvx-badge\"\u003eSingle \/ Multi-zone capable indoor\u003c\/span\u003e\n\u003c\/div\u003e\n\u003cul style=\"margin: 12px 0 0; padding-left: 18px;\"\u003e\n\u003cli\u003e\n\u003cstrong\u003eCold-climate heating:\u003c\/strong\u003e Hyper Heating outdoor unit rated to operate in heating down to −22°F.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQuiet efficiency:\u003c\/strong\u003e 12Hz ultra-low compressor speed supports smooth, efficient operation.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFast comfort:\u003c\/strong\u003e High-Frequency Racer Technology targets rapid temperature control at startup.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOptimized refrigerant control:\u003c\/strong\u003e electronic expansion valve (EEV) helps manage refrigerant flow precisely.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eControl options:\u003c\/strong\u003e Smart Kit app control, included remote control; wall thermostat optional (sold separately).\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cdiv aria-label=\"At-a-glance\" role=\"list\" class=\"hvx-kv\"\u003e\n\u003cdiv role=\"listitem\"\u003e\n\u003cstrong\u003eIndoor\u003c\/strong\u003eCH-RB12MOLVWM-230VI\u003c\/div\u003e\n\u003cdiv role=\"listitem\"\u003e\n\u003cstrong\u003eOutdoor\u003c\/strong\u003eCH-RHP12-230VO\u003c\/div\u003e\n\u003cdiv role=\"listitem\"\u003e\n\u003cstrong\u003eLines\u003c\/strong\u003e1\/4\" liquid · 3\/8\" gas\u003c\/div\u003e\n\u003cdiv role=\"listitem\"\u003e\n\u003cstrong\u003eMax run\u003c\/strong\u003e82 ft\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"hvx-desc-card\"\u003e\n\u003ch2 class=\"hvx-section-title\"\u003eWhat’s Included\u003c\/h2\u003e\n\u003cul style=\"padding-left: 18px; margin: 8px 0;\"\u003e\n\u003cli\u003eIndoor unit: CH-RB12MOLVWM-230VI (Olivia Midnight Black)\u003c\/li\u003e\n\u003cli\u003eOutdoor unit: CH-RHP12-230VO (Hyper Heating)\u003c\/li\u003e\n\u003cli\u003eRG10K-exclusive remote control (included)\u003c\/li\u003e\n\u003cli\u003eSmart Kit for app control\u003c\/li\u003e\n\u003cli\u003eManufacturer documentation (see Documents \u0026amp; Downloads)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"hvx-desc-card\"\u003e\n\u003ch2 class=\"hvx-section-title\"\u003eIndoor Specs\u003c\/h2\u003e\n\u003cdiv class=\"hvx-table-wrap\"\u003e\n\u003ctable aria-label=\"Indoor unit specifications\" class=\"hvx-table\"\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eSpec\u003c\/th\u003e\n\u003cth\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCH-RB12MOLVWM-230VI\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSystem type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSingle\/Multi-zone unit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRefrigerant type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eR454B\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBTU rated\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e12,000\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower source\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e208–230V, 1Ph, 60Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eVoltage range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e187–253 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSEER2\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e23.1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEER2\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e13\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDehumidification\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2.83 pnt\/day\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRefrigerant piping (liq\/gas)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1\/4\" \/ 3\/8\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMinimum circuit ampacity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMax fuse\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e15\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIndoor noise level (H\/M\/L)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e42 \/ 36 \/ 25\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIndoor air flow\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e341.18 \/ 291.18 \/ 194.12 \/ 152.94\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eUnit dimensions (W×H×D)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e31.57 × 11.61 × 7.87 in\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNet \/ Gross weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e18.74 \/ 24.25\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePacking dimensions (W×D×H)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e34.45 × 11.22 × 14.96\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDrainage water pipe diameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e5\/8\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating range (Cooling)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e60–90\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating range (Heating)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e32–86\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eController\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eRG10K-exclusive remote\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"hvx-desc-card\"\u003e\n\u003ch2 class=\"hvx-section-title\"\u003eOutdoor Specs\u003c\/h2\u003e\n\u003cdiv class=\"hvx-table-wrap\"\u003e\n\u003ctable aria-label=\"Outdoor unit specifications\" class=\"hvx-table\"\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eSpec\u003c\/th\u003e\n\u003cth\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCH-RHP12-230VO\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSystem type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSingle-zone unit (Hyper Heating)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRefrigerant type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eR454B\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBTU rated\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e12,000\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower source\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e208–230V, 1Ph, 60Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eVoltage range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e187–253 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRefrigerant piping (liq\/gas)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1\/4\" \/ 3\/8\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMax pipe length\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e82 ft\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMax height difference (IDU↔ODU)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e49.2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCooling capacity (Min\/Max)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e12,000 (3,800~14,600)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eHeating capacity (Min\/Max)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e12,000 (3,800~16,000)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eHSPF2-5\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eHSPF2-4\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e10.5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCOP\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3.76\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDehumidification\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2.54 pnt\/day\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOutdoor noise level\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e56\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOutdoor air flow\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1,470.6\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMinimum circuit ampacity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e15\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMax fuse\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e15\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAmbient temp (Heating)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e−22~75\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAmbient temp (Cooling)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e−22~122\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eUnit dimensions (W×H×D)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e31.69 × 12.99 × 21.81\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNet \/ Gross weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e72.75\/78.70\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePacking dimensions (W×D×H)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e36.02 × 14.57 × 24.21\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRefrigerant precharge\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e25\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAdditional charge (1\/4\" liquid)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.16\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"hvx-desc-card\"\u003e\n\u003ch2 class=\"hvx-section-title\"\u003eDocuments \u0026amp; Downloads\u003c\/h2\u003e\n\u003cul style=\"padding-left: 18px; margin: 8px 0;\"\u003e\n\u003cli\u003e\u003ca rel=\"noopener\" href=\"https:\/\/media.cooperandhunter.us\/4963\/CH-RB12MOLVWM-230VI.pdf\" class=\"hvx-link\" target=\"_blank\"\u003eSubmittal (PDF) — CH-RB12MOLVWM-230VI\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca rel=\"noopener\" href=\"https:\/\/media.cooperandhunter.us\/4954\/CH-RES12-230VO-_-CH-RB12MOLVWM-230VI.pdf\" class=\"hvx-link\" target=\"_blank\"\u003eSubmittal (PDF) — CH-RES12-230VO + CH-RB12MOLVWM-230VI\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca rel=\"noopener\" href=\"https:\/\/media.cooperandhunter.us\/4959\/CH-RHP12-230VO_CH-RB12MOLVWM-230VI.pdf\" class=\"hvx-link\" target=\"_blank\"\u003eSubmittal (PDF) — CH-RHP12-230VO + CH-RB12MOLVWM-230VI\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca rel=\"noopener\" href=\"https:\/\/media.cooperandhunter.us\/4170\/CH-RHP12-230VO-%2B-CH-RH12MASTWM-230VI.pdf\" class=\"hvx-link\" target=\"_blank\"\u003eSubmittal (PDF) — CH-RHP12-230VO + CH-RH12MASTWM-230VI\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca rel=\"noopener\" href=\"https:\/\/media.cooperandhunter.us\/4203\/CH-RHP12-230VO-%2B-CH-RS06-12MDT--MS.pdf\" class=\"hvx-link\" target=\"_blank\"\u003eSubmittal (PDF) — CH-RHP12-230VO + CH-RS06-12MDT (MS)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca rel=\"noopener\" href=\"https:\/\/media.cooperandhunter.us\/4682\/CH-RHP09-230VO_CH-RH09MCT.pdf\" class=\"hvx-link\" target=\"_blank\"\u003eSubmittal (PDF) — CH-RHP09-230VO + CH-RH09MCT\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca rel=\"noopener\" href=\"https:\/\/media.cooperandhunter.us\/4683\/CH-RHP09-230VO_CH-RSH09MCT.pdf\" class=\"hvx-link\" target=\"_blank\"\u003eSubmittal (PDF) — CH-RHP09-230VO + CH-RSH09MCT\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca rel=\"noopener\" href=\"https:\/\/media.cooperandhunter.us\/4118\/Installation-Manual-R454B-Outdoor-units--.pdf\" class=\"hvx-link\" target=\"_blank\"\u003eInstallation Manual (PDF) — R454B Outdoor Units\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca rel=\"noopener\" href=\"https:\/\/media.cooperandhunter.us\/4200\/SlimDuct-Leaflet-R454B.pdf\" class=\"hvx-link\" target=\"_blank\"\u003eSlimDuct Leaflet (PDF) — R454B\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca rel=\"noopener\" href=\"https:\/\/www.ahridirectory.org\" class=\"hvx-link\" target=\"_blank\"\u003eAHRI Directory Listing — AHRI #207742320\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca rel=\"noopener\" href=\"https:\/\/cooperandhunter.us\/product\/ch-rb12molvwm-230vi\" class=\"hvx-link\" target=\"_blank\"\u003eManufacturer Page — CH-RB12MOLVWM-230VI\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca rel=\"noopener\" href=\"https:\/\/cooperandhunter.us\/product\/ch-rhp12-230vo\" class=\"hvx-link\" target=\"_blank\"\u003eManufacturer Page — CH-RHP12-230VO\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"hvx-desc-card\"\u003e\n\u003ch2 class=\"hvx-section-title\"\u003eImportant\u003c\/h2\u003e\n\u003cp style=\"margin: 0; font-size: 14px; color: var(--hvx-slate);\"\u003eProfessional installation is recommended. Confirm electrical requirements, line sizes, maximum line length, and ambient operating limits before installation.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"hvx-desc-card\"\u003e\n\u003ch2 class=\"hvx-section-title\"\u003eFAQs\u003c\/h2\u003e\n\u003cdetails open=\"\" class=\"hvx-faq\"\u003e\n\u003csummary\u003eIs this system “Hyper Heat”?\u003c\/summary\u003e\n\u003cdiv style=\"margin-top: 8px;\"\u003eYes. The CH-RHP12-230VO outdoor unit is a Hyper Heating model rated to operate in heating down to −22°F.\u003c\/div\u003e\n\u003c\/details\u003e\n\u003cdetails open=\"\" class=\"hvx-faq\"\u003e\n\u003csummary\u003eWhat line sizes does this system use?\u003c\/summary\u003e\n\u003cdiv style=\"margin-top: 8px;\"\u003e1\/4\" liquid and 3\/8\" gas.\u003c\/div\u003e\n\u003c\/details\u003e\n\u003cdetails open=\"\" class=\"hvx-faq\"\u003e\n\u003csummary\u003eWhat is the max line length and height difference?\u003c\/summary\u003e\n\u003cdiv style=\"margin-top: 8px;\"\u003eMaximum line length is 82 ft and maximum height difference is 49.2.\u003c\/div\u003e\n\u003c\/details\u003e\n\u003cdetails open=\"\" class=\"hvx-faq\"\u003e\n\u003csummary\u003eWhat is the outdoor heating and cooling ambient range?\u003c\/summary\u003e\n\u003cdiv style=\"margin-top: 8px;\"\u003eCooling: −22~122. Heating: −22~75.\u003c\/div\u003e\n\u003c\/details\u003e\n\u003cdetails open=\"\" class=\"hvx-faq\"\u003e\n\u003csummary\u003eWhat controls are supported?\u003c\/summary\u003e\n\u003cdiv style=\"margin-top: 8px;\"\u003eSmart Kit app control and RG10K-exclusive remote are included; a wall thermostat can be purchased separately.\u003c\/div\u003e\n\u003c\/details\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e","brand":"Cooper\u0026Hunter","offers":[{"title":"No installation","offer_id":42675499368491,"sku":"CH-RB12MOLVWM-230VI + CH-RHP12-230VO","price":1389.0,"currency_code":"USD","in_stock":true},{"title":"16FT","offer_id":42675499401259,"sku":"CH-RB12MOLVWM-230VI + CH-RHP12-230VO","price":1570.0,"currency_code":"USD","in_stock":true},{"title":"25FT","offer_id":42675499434027,"sku":"CH-RB12MOLVWM-230VI + CH-RHP12-230VO","price":1616.0,"currency_code":"USD","in_stock":true},{"title":"50FT","offer_id":42675499466795,"sku":"CH-RB12MOLVWM-230VI + CH-RHP12-230VO","price":1837.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0625\/5647\/1339\/files\/12_b44b24b4-03fa-4830-8afc-e22e19e71fbe.png?v=1769199597"},{"product_id":"cooper-hunter-18-000-btu-olivia-midnight-hyper-single-zone-wall-mount-minisplit-heat-pump-system-r454b-230v","title":"Cooper\u0026Hunter 18,000 BTU Olivia Midnight Hyper Single Zone Wall Mount Minisplit Heat Pump System R454B 230V","description":"\u003cstyle\u003e\n  :root{\n    --hvx-golden:#FAA819;\n    --hvx-slate:#262626;\n    --hvx-ivory:#F4F1E6;\n    --hvx-border:#e2e0d5;\n    --hvx-card-bg:#ffffff;\n  }\n\n  .hvx-desc{\n    font-family:\"Articulat CF\",system-ui,-apple-system,BlinkMacSystemFont,\"Segoe UI\",sans-serif;\n    color:var(--hvx-slate);\n    line-height:1.6;\n    background:var(--hvx-ivory);\n    padding:18px 18px 20px;\n    border-radius:16px;\n  }\n\n  .hvx-desc-header{\n    border-radius:14px;\n    padding:14px 16px;\n    background:linear-gradient(120deg,var(--hvx-golden),var(--hvx-slate));\n    color:#fff;\n    margin:0 0 16px;\n    box-shadow:0 10px 24px rgba(0,0,0,.22);\n    display:flex;\n    align-items:flex-start;\n    gap:12px;\n    flex-wrap:wrap;\n  }\n\n  .hvx-header-text{display:flex;flex-direction:column;gap:6px;min-width:260px}\n  .hvx-eyebrow{\n    font-size:11px;\n    letter-spacing:.14em;\n    text-transform:uppercase;\n    opacity:.9;\n  }\n  .hvx-title{\n    margin:0;\n    font-family:\"Anton\",\"Impact\",system-ui,-apple-system,BlinkMacSystemFont,\"Segoe UI\",sans-serif;\n    font-size:22px;\n    line-height:1.15;\n  }\n  .hvx-subtitle{margin:0;font-size:14px;opacity:.95}\n\n  .hvx-desc-card{\n    border:1px solid var(--hvx-border);\n    border-radius:14px;\n    background:var(--hvx-card-bg);\n    padding:16px 18px 18px;\n    box-shadow:0 4px 12px rgba(0,0,0,.06);\n    margin:14px 0;\n  }\n\n  .hvx-section-title{\n    margin:0 0 10px;\n    font-family:\"Anton\",\"Impact\",system-ui,-apple-system,BlinkMacSystemFont,\"Segoe UI\",sans-serif;\n    font-size:17px;\n    letter-spacing:.08em;\n    text-transform:uppercase;\n    color:var(--hvx-slate);\n    display:inline-flex;\n    align-items:center;\n    gap:8px;\n  }\n  .hvx-section-title::after{\n    content:\"\";\n    flex:1;\n    height:2px;\n    border-radius:999px;\n    background:linear-gradient(90deg,var(--hvx-golden),transparent);\n    opacity:.9;\n  }\n\n  .hvx-cta{display:flex;flex-wrap:wrap;gap:10px;margin:10px 0 0}\n  .hvx-cta a{\n    display:inline-flex;\n    align-items:center;\n    gap:8px;\n    padding:10px 14px;\n    border-radius:12px;\n    border:1px solid var(--hvx-border);\n    background:#fff;\n    text-decoration:none;\n    color:var(--hvx-slate);\n    font-size:14px;\n    font-weight:700;\n  }\n  .hvx-cta a.primary{\n    background:var(--hvx-slate);\n    color:#fff;\n    border-color:transparent;\n  }\n\n  .hvx-badges{display:flex;flex-wrap:wrap;gap:8px;margin:10px 0 0}\n  .hvx-badge{\n    font-size:12px;\n    border:1px solid var(--hvx-border);\n    border-radius:999px;\n    padding:6px 10px;\n    background:#fff;\n    white-space:nowrap;\n  }\n\n  .hvx-kv{\n    display:grid;\n    grid-template-columns:repeat(4,minmax(160px,1fr));\n    gap:10px;\n    margin-top:10px;\n  }\n  .hvx-kv \u003e div{\n    border:1px solid var(--hvx-border);\n    background:#fff;\n    border-radius:12px;\n    padding:10px 12px;\n    text-align:center;\n  }\n  .hvx-kv strong{display:block}\n\n  .hvx-table{\n    width:100%;\n    border-collapse:collapse;\n    min-width:520px;\n    background:#fff;\n    border:1px solid var(--hvx-border);\n    border-radius:12px;\n    overflow:hidden;\n  }\n  .hvx-table th,.hvx-table td{\n    border-bottom:1px solid var(--hvx-border);\n    padding:10px 12px;\n    vertical-align:top;\n    font-size:14px;\n  }\n  .hvx-table th{ text-align:left; font-weight:800; background:#fff; }\n  .hvx-table tr:nth-child(even) td{ background:#fbfaf6; }\n  .hvx-table tr:last-child td{ border-bottom:none; }\n  .hvx-table-wrap{ overflow:auto; border-radius:12px; }\n\n  .hvx-link{color:var(--hvx-slate); text-decoration:underline; text-underline-offset:2px}\n  .hvx-link:hover{opacity:.85}\n\n  details.hvx-faq{\n    border:1px solid var(--hvx-border);\n    background:#fff;\n    border-radius:12px;\n    padding:10px 12px;\n    margin:8px 0;\n  }\n  details.hvx-faq summary{cursor:pointer;font-weight:800}\n\n  @media(max-width:980px){\n    .hvx-kv{grid-template-columns:repeat(2,minmax(160px,1fr))}\n  }\n  @media(max-width:768px){\n    .hvx-desc{padding:14px 12px 16px;border-radius:12px}\n    .hvx-desc-header{padding:12px;border-radius:12px}\n    .hvx-title{font-size:19px}\n    .hvx-desc-card{padding:14px;margin:10px 0}\n  }\n\u003c\/style\u003e\n\u003cdiv class=\"hvx-desc\"\u003e\n\u003cdiv class=\"hvx-desc-header\"\u003e\n\u003cdiv class=\"hvx-header-text\"\u003e\n\u003cdiv class=\"hvx-eyebrow\"\u003eCooper\u0026amp;Hunter Olivia Midnight • Black • R454B • Hyper Heat\u003c\/div\u003e\n\u003ch1 class=\"hvx-title\"\u003eCooper\u0026amp;Hunter 18,000 BTU Olivia Midnight Single Zone Wall Mount Mini Split Heat Pump System R454B 230V\u003c\/h1\u003e\n\u003cp class=\"hvx-subtitle\"\u003e\u003cstrong\u003eSKU:\u003c\/strong\u003e CH-RB18MOLVWM-230VI + CH-RHP18-230VO\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv aria-label=\"Contact options\" class=\"hvx-cta\"\u003e\n\u003ca title=\"Contact Us\" rel=\"noopener\" href=\"https:\/\/hvacsupplies.com\/pages\/contact\" class=\"primary\" target=\"_blank\"\u003e CLICK HERE TO CONTACT US FOR CUSTOM QUOTES AND QUESTIONS \u003c\/a\u003e \u003ca title=\"Call Us Now!\" href=\"tel:+18005438933\"\u003e CLICK TO CALL US 800-543-8933 FOR ANY QUESTIONS \u003c\/a\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"hvx-desc-card\"\u003e\n\u003ch2 class=\"hvx-section-title\"\u003eOverview\u003c\/h2\u003e\n\u003cp style=\"margin: 0;\"\u003eTransform your home’s climate control with the Cooper\u0026amp;Hunter \u003cstrong\u003e18K BTU Olivia Midnight\u003c\/strong\u003e wall-mounted mini split system, showcasing the new \u003cstrong\u003eR454B refrigerant\u003c\/strong\u003e and an elegant \u003cstrong\u003eblack\u003c\/strong\u003e indoor unit for a modern, premium look. Designed for \u003cstrong\u003e208–230V\u003c\/strong\u003e installations, Olivia Midnight combines advanced comfort features with efficient performance, delivering up to \u003cstrong\u003e21.7 SEER2\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp style=\"margin: 10px 0 0;\"\u003eComfort and convenience features include \u003cstrong\u003eAuto-Swing\u003c\/strong\u003e horizontal louvers for improved air circulation, \u003cstrong\u003eTurbo Mode\u003c\/strong\u003e for rapid heating\/cooling, \u003cstrong\u003eFollow Me\u003c\/strong\u003e sensing from the remote, \u003cstrong\u003eTimer On\/Off\u003c\/strong\u003e and \u003cstrong\u003eSleep Mode\u003c\/strong\u003e, plus \u003cstrong\u003e46° Freeze Protection\u003c\/strong\u003e. Advanced technology includes \u003cstrong\u003e12Hz\u003c\/strong\u003e ultra-low compressor speed for quiet efficiency, \u003cstrong\u003eHigh-Frequency Racer Technology\u003c\/strong\u003e for fast startup response, an \u003cstrong\u003eelectronic expansion valve\u003c\/strong\u003e for optimized refrigerant flow management, and an \u003cstrong\u003eintelligent dusting switch\u003c\/strong\u003e that reverses the fan to help clear dust, sand, and debris from the coil. Built with \u003cstrong\u003eTU1 copper tubes\u003c\/strong\u003e for durability and efficient heat transfer.\u003c\/p\u003e\n\u003cp style=\"margin: 10px 0 0;\"\u003eThe included \u003cstrong\u003eHyper Heating\u003c\/strong\u003e outdoor unit is engineered for cold climates and is rated for heating operation down to \u003cstrong\u003e−22°F\u003c\/strong\u003e.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"hvx-desc-card\"\u003e\n\u003ch2 class=\"hvx-section-title\"\u003eHighlights\u003c\/h2\u003e\n\u003cdiv role=\"list\" class=\"hvx-badges\"\u003e\n\u003cspan role=\"listitem\" class=\"hvx-badge\"\u003e18,000 BTU class\u003c\/span\u003e \u003cspan role=\"listitem\" class=\"hvx-badge\"\u003eOlivia Midnight (Black indoor)\u003c\/span\u003e \u003cspan role=\"listitem\" class=\"hvx-badge\"\u003eR454B refrigerant\u003c\/span\u003e \u003cspan role=\"listitem\" class=\"hvx-badge\"\u003eSEER2 21.7 (Indoor)\u003c\/span\u003e \u003cspan role=\"listitem\" class=\"hvx-badge\"\u003eEER2 13.5 (Indoor)\u003c\/span\u003e \u003cspan role=\"listitem\" class=\"hvx-badge\"\u003eHyper Heat to −22°F (Outdoor)\u003c\/span\u003e \u003cspan role=\"listitem\" class=\"hvx-badge\"\u003eSmart Kit included\u003c\/span\u003e \u003cspan role=\"listitem\" class=\"hvx-badge\"\u003eAuto-swing (horizontal louvers)\u003c\/span\u003e \u003cspan role=\"listitem\" class=\"hvx-badge\"\u003e208–230V, 1Ph, 60Hz\u003c\/span\u003e \u003cspan role=\"listitem\" class=\"hvx-badge\"\u003eSingle \/ Multi-zone capable indoor\u003c\/span\u003e\n\u003c\/div\u003e\n\u003cul style=\"margin: 12px 0 0; padding-left: 18px;\"\u003e\n\u003cli\u003e\n\u003cstrong\u003eCold-climate heating:\u003c\/strong\u003e Hyper Heating outdoor unit rated to operate in heating down to −22°F.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQuiet efficiency:\u003c\/strong\u003e 12Hz ultra-low compressor speed supports smooth, efficient operation.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFast comfort:\u003c\/strong\u003e High-Frequency Racer Technology targets rapid temperature control at startup.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOptimized refrigerant control:\u003c\/strong\u003e electronic expansion valve (EEV) helps manage refrigerant flow precisely.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eControl options:\u003c\/strong\u003e Smart Kit app control, included RG10K-exclusive remote; wall thermostat optional (sold separately).\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cdiv aria-label=\"At-a-glance\" role=\"list\" class=\"hvx-kv\"\u003e\n\u003cdiv role=\"listitem\"\u003e\n\u003cstrong\u003eIndoor\u003c\/strong\u003eCH-RB18MOLVWM-230VI\u003c\/div\u003e\n\u003cdiv role=\"listitem\"\u003e\n\u003cstrong\u003eOutdoor\u003c\/strong\u003eCH-RHP18-230VO\u003c\/div\u003e\n\u003cdiv role=\"listitem\"\u003e\n\u003cstrong\u003eLines\u003c\/strong\u003e1\/4\" liquid · 1\/2\" gas\u003c\/div\u003e\n\u003cdiv role=\"listitem\"\u003e\n\u003cstrong\u003eMax run\u003c\/strong\u003e98.4 ft\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"hvx-desc-card\"\u003e\n\u003ch2 class=\"hvx-section-title\"\u003eWhat’s Included\u003c\/h2\u003e\n\u003cul style=\"padding-left: 18px; margin: 8px 0;\"\u003e\n\u003cli\u003eIndoor unit: CH-RB18MOLVWM-230VI (Olivia Midnight Black)\u003c\/li\u003e\n\u003cli\u003eOutdoor unit: CH-RHP18-230VO (Hyper Heating)\u003c\/li\u003e\n\u003cli\u003eRG10K-exclusive remote control (included)\u003c\/li\u003e\n\u003cli\u003eSmart Kit for app control\u003c\/li\u003e\n\u003cli\u003eManufacturer documentation (see Documents \u0026amp; Downloads)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"hvx-desc-card\"\u003e\n\u003ch2 class=\"hvx-section-title\"\u003eIndoor Specs\u003c\/h2\u003e\n\u003cdiv class=\"hvx-table-wrap\"\u003e\n\u003ctable aria-label=\"Indoor unit specifications\" class=\"hvx-table\"\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eSpec\u003c\/th\u003e\n\u003cth\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCH-RB18MOLVWM-230VI\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSystem type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSingle\/Multi-zone unit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRefrigerant type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eR454B\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBTU rated\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e18,000\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower source\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e208–230V, 1Ph, 60Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eVoltage range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e187–253 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSEER2\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e24\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEER2\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e13.5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDehumidification\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3.28 pnt\/day\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRefrigerant piping (liq\/gas)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1\/4\" \/ 1\/2\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMinimum circuit ampacity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMax fuse\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e15\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIndoor noise level (H\/M\/L)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e45.5 \/ 41 \/ 24.5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIndoor air flow\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e760.59 \/ 530.59 \/ 458.82 \/ 382.35\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eUnit dimensions (W×H×D)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e42.64 × 13.23 × 9.61\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNet \/ Gross weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e29.54 \/ 37.48\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePacking dimensions (W×D×H)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e45.47 × 12.40 × 16.34\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDrainage water pipe diameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e5\/8\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating range (Cooling)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e60–90\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating range (Heating)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e32–86\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eController\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eRG10K-exclusive remote\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"hvx-desc-card\"\u003e\n\u003ch2 class=\"hvx-section-title\"\u003eOutdoor Specs\u003c\/h2\u003e\n\u003cdiv class=\"hvx-table-wrap\"\u003e\n\u003ctable aria-label=\"Outdoor unit specifications\" class=\"hvx-table\"\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eSpec\u003c\/th\u003e\n\u003cth\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCH-RHP18-230VO\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSystem type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSingle-zone unit (Hyper Heating)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRefrigerant type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eR454B\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBTU rated\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e18,000\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower source\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e208–230V, 1Ph, 60Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eVoltage range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e187–253 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRefrigerant piping (liq\/gas)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1\/4\" \/ 1\/2\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMax pipe length\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e98.4 ft\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMax height difference (IDU↔ODU)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e65.6\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCooling capacity (Min\/Max)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e17,000 (6,500~18,800)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eHeating capacity (Min\/Max)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e19,000 (8,900~22,000)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSEER2\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e18\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEER2\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e12\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eHSPF2-5\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e9\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eHSPF2-4\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e10.5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCOP\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3.37\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDehumidification\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3.53 pnt\/day\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOutdoor noise level\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e59\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOutdoor air flow\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1,765.8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMinimum circuit ampacity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e19\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMax fuse\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAmbient temp (Heating)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e−22~75\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAmbient temp (Cooling)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e−22~122\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eUnit dimensions (W×H×D)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e35.04 × 13.46 × 26.50\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNet \/ Gross weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e99.87\/107.80\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePacking dimensions (W×D×H)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e39.17 × 15.67 × 29.13\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRefrigerant precharge\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e25\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAdditional charge (1\/4\" liquid)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.16\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"hvx-desc-card\"\u003e\n\u003ch2 class=\"hvx-section-title\"\u003eDocuments \u0026amp; Downloads\u003c\/h2\u003e\n\u003cul style=\"padding-left: 18px; margin: 8px 0;\"\u003e\n\u003cli\u003e\u003ca rel=\"noopener\" href=\"https:\/\/media.cooperandhunter.us\/4960\/CH-RHP18-230VO_CH-RB18MOLVWM-230VI.pdf\" class=\"hvx-link\" target=\"_blank\"\u003eSubmittal (PDF) — CH-RHP18-230VO + CH-RB18MOLVWM-230VI\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca rel=\"noopener\" href=\"https:\/\/media.cooperandhunter.us\/4964\/CH-RB18MOLVWM-230VI.pdf\" class=\"hvx-link\" target=\"_blank\"\u003eSubmittal (PDF) — CH-RB18MOLVWM-230VI\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca rel=\"noopener\" href=\"https:\/\/media.cooperandhunter.us\/4955\/CH-RES18-230VO-_-CH-RB18MOLVWM-230VI.pdf\" class=\"hvx-link\" target=\"_blank\"\u003eSubmittal (PDF) — CH-RES18-230VO + CH-RB18MOLVWM-230VI\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca rel=\"noopener\" href=\"https:\/\/media.cooperandhunter.us\/4158\/CH-RHP18-230VO-%2B-CH-PRO18MASTWM-230VI.pdf\" class=\"hvx-link\" target=\"_blank\"\u003eSubmittal (PDF) — CH-RHP18-230VO + CH-PRO18MASTWM-230VI\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca rel=\"noopener\" href=\"https:\/\/media.cooperandhunter.us\/4172\/CH-RHP18-230VO-%2B-CH-RH18MASTWM-230VI.pdf\" class=\"hvx-link\" target=\"_blank\"\u003eSubmittal (PDF) — CH-RHP18-230VO + CH-RH18MASTWM-230VI\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca rel=\"noopener\" href=\"https:\/\/media.cooperandhunter.us\/4204\/CH-RHP18-230VO-%2B-CH-RS18MDT-MS.pdf\" class=\"hvx-link\" target=\"_blank\"\u003eSubmittal (PDF) — CH-RHP18-230VO + CH-RS18MDT (MS)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca rel=\"noopener\" href=\"https:\/\/media.cooperandhunter.us\/4251\/CH-RHP18-230VO-%2B-CH-RS18MAHU.pdf\" class=\"hvx-link\" target=\"_blank\"\u003eSubmittal (PDF) — CH-RHP18-230VO + CH-RS18MAHU\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca rel=\"noopener\" href=\"https:\/\/media.cooperandhunter.us\/4630\/CH-RHP18-230VO_CH-RSH18MFC.pdf\" class=\"hvx-link\" target=\"_blank\"\u003eSubmittal (PDF) — CH-RHP18-230VO + CH-RSH18MFC\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca rel=\"noopener\" href=\"https:\/\/media.cooperandhunter.us\/4686\/CH-RHP18-230VO_CH-RH18MCT.pdf\" class=\"hvx-link\" target=\"_blank\"\u003eSubmittal (PDF) — CH-RHP18-230VO + CH-RH18MCT\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca rel=\"noopener\" href=\"https:\/\/media.cooperandhunter.us\/4687\/CH-RHP18-230VO_CH-RSH18MCT.pdf\" class=\"hvx-link\" target=\"_blank\"\u003eSubmittal (PDF) — CH-RHP18-230VO + CH-RSH18MCT\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca rel=\"noopener\" href=\"https:\/\/media.cooperandhunter.us\/4118\/Installation-Manual-R454B-Outdoor-units--.pdf\" class=\"hvx-link\" target=\"_blank\"\u003eInstallation Manual (PDF) — R454B Outdoor Units\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca rel=\"noopener\" href=\"https:\/\/media.cooperandhunter.us\/4200\/SlimDuct-Leaflet-R454B.pdf\" class=\"hvx-link\" target=\"_blank\"\u003eSlimDuct Leaflet (PDF) — R454B\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca rel=\"noopener\" href=\"https:\/\/www.ahridirectory.org\/NewSearch?programId=41\u0026amp;searchTypeId=3\u0026amp;productTypeId=4\" class=\"hvx-link\" target=\"_blank\"\u003eAHRI Directory Listing — AHRI #207742320\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca rel=\"noopener\" href=\"https:\/\/cooperandhunter.us\/product\/ch-rb18molvwm-230vi\" class=\"hvx-link\" target=\"_blank\"\u003eManufacturer Page — CH-RB18MOLVWM-230VI\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca rel=\"noopener\" href=\"https:\/\/cooperandhunter.us\/product\/ch-rhp18-230vo\" class=\"hvx-link\" target=\"_blank\"\u003eManufacturer Page — CH-RHP18-230VO\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"hvx-desc-card\"\u003e\n\u003ch2 class=\"hvx-section-title\"\u003eImportant\u003c\/h2\u003e\n\u003cp style=\"margin: 0; font-size: 14px; color: var(--hvx-slate);\"\u003eProfessional installation is recommended. Confirm electrical requirements, line sizes, maximum line length, and ambient operating limits before installation.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"hvx-desc-card\"\u003e\n\u003ch2 class=\"hvx-section-title\"\u003eFAQs\u003c\/h2\u003e\n\u003cdetails open=\"\" class=\"hvx-faq\"\u003e\n\u003csummary\u003eIs this system “Hyper Heat”?\u003c\/summary\u003e\n\u003cdiv style=\"margin-top: 8px;\"\u003eYes. The CH-RHP18-230VO outdoor unit is a Hyper Heating model rated to operate in heating down to −22°F.\u003c\/div\u003e\n\u003c\/details\u003e\n\u003cdetails open=\"\" class=\"hvx-faq\"\u003e\n\u003csummary\u003eWhat line sizes does this system use?\u003c\/summary\u003e\n\u003cdiv style=\"margin-top: 8px;\"\u003e1\/4\" liquid and 1\/2\" gas.\u003c\/div\u003e\n\u003c\/details\u003e\n\u003cdetails open=\"\" class=\"hvx-faq\"\u003e\n\u003csummary\u003eWhat is the max line length and height difference?\u003c\/summary\u003e\n\u003cdiv style=\"margin-top: 8px;\"\u003eMaximum line length is 98.4 ft and maximum height difference is 65.6.\u003c\/div\u003e\n\u003c\/details\u003e\n\u003cdetails open=\"\" class=\"hvx-faq\"\u003e\n\u003csummary\u003eWhat is the outdoor heating and cooling ambient range?\u003c\/summary\u003e\n\u003cdiv style=\"margin-top: 8px;\"\u003eCooling: −22~122. Heating: −22~75.\u003c\/div\u003e\n\u003c\/details\u003e\n\u003cdetails open=\"\" class=\"hvx-faq\"\u003e\n\u003csummary\u003eWhat controls are supported?\u003c\/summary\u003e\n\u003cdiv style=\"margin-top: 8px;\"\u003eSmart Kit app control and RG10K-exclusive remote are included; a wall thermostat can be purchased separately.\u003c\/div\u003e\n\u003c\/details\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e","brand":"Cooper\u0026Hunter","offers":[{"title":"No installation","offer_id":42690234515499,"sku":"CH-RB18MOLVWM-230VI + CH-RHP18-230VO","price":2003.0,"currency_code":"USD","in_stock":true},{"title":"16FT","offer_id":42690234548267,"sku":"CH-RB18MOLVWM-230VI + CH-RHP18-230VO","price":2212.0,"currency_code":"USD","in_stock":true},{"title":"25FT","offer_id":42690234581035,"sku":"CH-RB18MOLVWM-230VI + CH-RHP18-230VO","price":2257.0,"currency_code":"USD","in_stock":true},{"title":"50FT","offer_id":42690234613803,"sku":"CH-RB18MOLVWM-230VI + CH-RHP18-230VO","price":2460.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0625\/5647\/1339\/files\/12_b44b24b4-03fa-4830-8afc-e22e19e71fbe.png?v=1769199597"},{"product_id":"cooper-hunter-24-000-btu-olivia-midnight-hyper-single-zone-wall-mount-minisplit-heat-pump-system-r454b-230v","title":"Cooper\u0026Hunter 24,000 BTU Olivia Midnight Hyper Single Zone Wall Mount Minisplit Heat Pump System R454B 230V","description":"\u003cstyle\u003e\n  :root{\n    --hvx-golden:#FAA819;\n    --hvx-slate:#262626;\n    --hvx-ivory:#F4F1E6;\n    --hvx-border:#e2e0d5;\n    --hvx-card-bg:#ffffff;\n  }\n\n  .hvx-desc{\n    font-family:\"Articulat CF\",system-ui,-apple-system,BlinkMacSystemFont,\"Segoe UI\",sans-serif;\n    color:var(--hvx-slate);\n    line-height:1.6;\n    background:var(--hvx-ivory);\n    padding:18px 18px 20px;\n    border-radius:16px;\n  }\n\n  .hvx-desc-header{\n    border-radius:14px;\n    padding:14px 16px;\n    background:linear-gradient(120deg,var(--hvx-golden),var(--hvx-slate));\n    color:#fff;\n    margin:0 0 16px;\n    box-shadow:0 10px 24px rgba(0,0,0,.22);\n    display:flex;\n    align-items:flex-start;\n    gap:12px;\n    flex-wrap:wrap;\n  }\n\n  .hvx-header-text{display:flex;flex-direction:column;gap:6px;min-width:260px}\n  .hvx-eyebrow{\n    font-size:11px;\n    letter-spacing:.14em;\n    text-transform:uppercase;\n    opacity:.9;\n  }\n  .hvx-title{\n    margin:0;\n    font-family:\"Anton\",\"Impact\",system-ui,-apple-system,BlinkMacSystemFont,\"Segoe UI\",sans-serif;\n    font-size:22px;\n    line-height:1.15;\n  }\n  .hvx-subtitle{margin:0;font-size:14px;opacity:.95}\n\n  .hvx-desc-card{\n    border:1px solid var(--hvx-border);\n    border-radius:14px;\n    background:var(--hvx-card-bg);\n    padding:16px 18px 18px;\n    box-shadow:0 4px 12px rgba(0,0,0,.06);\n    margin:14px 0;\n  }\n\n  .hvx-section-title{\n    margin:0 0 10px;\n    font-family:\"Anton\",\"Impact\",system-ui,-apple-system,BlinkMacSystemFont,\"Segoe UI\",sans-serif;\n    font-size:17px;\n    letter-spacing:.08em;\n    text-transform:uppercase;\n    color:var(--hvx-slate);\n    display:inline-flex;\n    align-items:center;\n    gap:8px;\n  }\n  .hvx-section-title::after{\n    content:\"\";\n    flex:1;\n    height:2px;\n    border-radius:999px;\n    background:linear-gradient(90deg,var(--hvx-golden),transparent);\n    opacity:.9;\n  }\n\n  .hvx-cta{display:flex;flex-wrap:wrap;gap:10px;margin:10px 0 0}\n  .hvx-cta a{\n    display:inline-flex;\n    align-items:center;\n    gap:8px;\n    padding:10px 14px;\n    border-radius:12px;\n    border:1px solid var(--hvx-border);\n    background:#fff;\n    text-decoration:none;\n    color:var(--hvx-slate);\n    font-size:14px;\n    font-weight:700;\n  }\n  .hvx-cta a.primary{\n    background:var(--hvx-slate);\n    color:#fff;\n    border-color:transparent;\n  }\n\n  .hvx-badges{display:flex;flex-wrap:wrap;gap:8px;margin:10px 0 0}\n  .hvx-badge{\n    font-size:12px;\n    border:1px solid var(--hvx-border);\n    border-radius:999px;\n    padding:6px 10px;\n    background:#fff;\n    white-space:nowrap;\n  }\n\n  .hvx-kv{\n    display:grid;\n    grid-template-columns:repeat(4,minmax(160px,1fr));\n    gap:10px;\n    margin-top:10px;\n  }\n  .hvx-kv \u003e div{\n    border:1px solid var(--hvx-border);\n    background:#fff;\n    border-radius:12px;\n    padding:10px 12px;\n    text-align:center;\n  }\n  .hvx-kv strong{display:block}\n\n  .hvx-table{\n    width:100%;\n    border-collapse:collapse;\n    min-width:520px;\n    background:#fff;\n    border:1px solid var(--hvx-border);\n    border-radius:12px;\n    overflow:hidden;\n  }\n  .hvx-table th,.hvx-table td{\n    border-bottom:1px solid var(--hvx-border);\n    padding:10px 12px;\n    vertical-align:top;\n    font-size:14px;\n  }\n  .hvx-table th{ text-align:left; font-weight:800; background:#fff; }\n  .hvx-table tr:nth-child(even) td{ background:#fbfaf6; }\n  .hvx-table tr:last-child td{ border-bottom:none; }\n  .hvx-table-wrap{ overflow:auto; border-radius:12px; }\n\n  .hvx-link{color:var(--hvx-slate); text-decoration:underline; text-underline-offset:2px}\n  .hvx-link:hover{opacity:.85}\n\n  details.hvx-faq{\n    border:1px solid var(--hvx-border);\n    background:#fff;\n    border-radius:12px;\n    padding:10px 12px;\n    margin:8px 0;\n  }\n  details.hvx-faq summary{cursor:pointer;font-weight:800}\n\n  @media(max-width:980px){\n    .hvx-kv{grid-template-columns:repeat(2,minmax(160px,1fr))}\n  }\n  @media(max-width:768px){\n    .hvx-desc{padding:14px 12px 16px;border-radius:12px}\n    .hvx-desc-header{padding:12px;border-radius:12px}\n    .hvx-title{font-size:19px}\n    .hvx-desc-card{padding:14px;margin:10px 0}\n  }\n\u003c\/style\u003e\n\u003cdiv class=\"hvx-desc\"\u003e\n\u003cdiv class=\"hvx-desc-header\"\u003e\n\u003cdiv class=\"hvx-header-text\"\u003e\n\u003cdiv class=\"hvx-eyebrow\"\u003eCooper\u0026amp;Hunter Olivia • R454B • Hyper Heat\u003c\/div\u003e\n\u003ch1 class=\"hvx-title\"\u003eCooper\u0026amp;Hunter 24,000 BTU Olivia Single Zone Wall Mount Mini Split Heat Pump System R454B 230V\u003c\/h1\u003e\n\u003cp class=\"hvx-subtitle\"\u003e\u003cstrong\u003eSKU:\u003c\/strong\u003e CH-R24MOLVWM-230VI + CH-RHP24-230VO\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"hvx-cta\" aria-label=\"Contact options\"\u003e\n\u003ca class=\"primary\" href=\"https:\/\/hvacsupplies.com\/pages\/contact\" rel=\"noopener\" title=\"Contact Us\" target=\"_blank\"\u003e CLICK HERE TO CONTACT US FOR CUSTOM QUOTES AND QUESTIONS \u003c\/a\u003e \u003ca href=\"tel:+18005438933\" title=\"Call Us Now!\"\u003eCLICK TO CALL US 800-543-8933 FOR ANY QUESTIONS\u003c\/a\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"hvx-desc-card\"\u003e\n\u003ch2 class=\"hvx-section-title\"\u003eOverview\u003c\/h2\u003e\n\u003cp style=\"margin: 0;\"\u003eEnhance your home's climate control with the Cooper\u0026amp;Hunter \u003cstrong\u003e24K BTU Olivia\u003c\/strong\u003e wall-mounted mini split utilizing \u003cstrong\u003eR454B\u003c\/strong\u003e refrigerant for improved efficiency and a lower environmental impact. With \u003cstrong\u003eup to 22.3 SEER2\u003c\/strong\u003e efficiency, this 230V system delivers powerful, modern comfort for larger spaces.\u003c\/p\u003e\n\u003cp style=\"margin: 10px 0 0;\"\u003eAuto-swing horizontal louvers help distribute air evenly, while inverter technology matches output to demand for efficient temperature control. Paired with a \u003cstrong\u003eHyper Heating\u003c\/strong\u003e outdoor unit, this system provides reliable heating performance down to \u003cstrong\u003e−22°F\u003c\/strong\u003e. Controls include Smart Kit app connectivity through the C\u0026amp;H app, an included remote, and optional wall thermostat compatibility (sold separately).\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"hvx-desc-card\"\u003e\n\u003ch2 class=\"hvx-section-title\"\u003eHighlights\u003c\/h2\u003e\n\u003cdiv class=\"hvx-badges\" role=\"list\"\u003e\n\u003cspan class=\"hvx-badge\" role=\"listitem\"\u003e24,000 BTU class\u003c\/span\u003e \u003cspan class=\"hvx-badge\" role=\"listitem\"\u003eR454B refrigerant\u003c\/span\u003e \u003cspan class=\"hvx-badge\" role=\"listitem\"\u003eUp to 22.3 SEER2\u003c\/span\u003e \u003cspan class=\"hvx-badge\" role=\"listitem\"\u003eHyper Heat to −22°F (Outdoor)\u003c\/span\u003e \u003cspan class=\"hvx-badge\" role=\"listitem\"\u003e208–230V, 1Ph, 60Hz\u003c\/span\u003e \u003cspan class=\"hvx-badge\" role=\"listitem\"\u003eSmart Kit included (App control)\u003c\/span\u003e \u003cspan class=\"hvx-badge\" role=\"listitem\"\u003eAuto-swing (horizontal louvers)\u003c\/span\u003e \u003cspan class=\"hvx-badge\" role=\"listitem\"\u003eTU1 copper tubes\u003c\/span\u003e\n\u003c\/div\u003e\n\u003cul style=\"margin: 12px 0 0; padding-left: 18px;\"\u003e\n\u003cli\u003e\n\u003cstrong\u003eHigh output comfort:\u003c\/strong\u003e designed for demanding heating and cooling needs in larger spaces.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e46°F freeze protection:\u003c\/strong\u003e added protection for cold conditions.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHigh-Frequency Racer Technology:\u003c\/strong\u003e rapid ramp to maximum speed on startup for quick comfort.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAdvanced refrigerant management:\u003c\/strong\u003e electronic expansion valve optimizes refrigerant flow control.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCleaner performance:\u003c\/strong\u003e intelligent dusting switch reverses the fan to help clear dust, sand, and debris from the coil.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eComfort automation:\u003c\/strong\u003e Follow Me, Timer On\/Off, Sleep Mode, and Turbo Mode.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cdiv class=\"hvx-kv\" role=\"list\" aria-label=\"At-a-glance\"\u003e\n\u003cdiv role=\"listitem\"\u003e\n\u003cstrong\u003eIndoor\u003c\/strong\u003eCH-R24MOLVWM-230VI\u003c\/div\u003e\n\u003cdiv role=\"listitem\"\u003e\n\u003cstrong\u003eOutdoor\u003c\/strong\u003eCH-RHP24-230VO\u003c\/div\u003e\n\u003cdiv role=\"listitem\"\u003e\n\u003cstrong\u003eLines\u003c\/strong\u003e3\/8\" liquid · 5\/8\" gas\u003c\/div\u003e\n\u003cdiv role=\"listitem\"\u003e\n\u003cstrong\u003eMax run\u003c\/strong\u003e164 ft\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"hvx-desc-card\"\u003e\n\u003ch2 class=\"hvx-section-title\"\u003eWhat’s Included\u003c\/h2\u003e\n\u003cul style=\"padding-left: 18px; margin: 8px 0;\"\u003e\n\u003cli\u003eIndoor unit: CH-R24MOLVWM-230VI\u003c\/li\u003e\n\u003cli\u003eOutdoor unit: CH-RHP24-230VO (Hyper Heating)\u003c\/li\u003e\n\u003cli\u003eRemote control\u003c\/li\u003e\n\u003cli\u003eSmart Kit (app connectivity)\u003c\/li\u003e\n\u003cli\u003eManufacturer documentation (see Downloads)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"hvx-desc-card\"\u003e\n\u003ch2 class=\"hvx-section-title\"\u003eIndoor Specs\u003c\/h2\u003e\n\u003cdiv class=\"hvx-table-wrap\"\u003e\n\u003ctable class=\"hvx-table\" aria-label=\"Indoor unit specifications\"\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eSpec\u003c\/th\u003e\n\u003cth\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIndoor Model\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCH-R24MOLVWM-230VI\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower Supply (Rated)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e208\/230 V, 1 Ø, 60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Capacity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e23,000 Btu\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMinimum Circuit Ampacity (MCA)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMax. fuse (A)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e15\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIndoor Air Flow (Turbo\/Hi\/Med\/Lo\/Si) (CFM)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e759.3 \/ 588.6 \/ 459.1 \/ 382.6 \/ N\/A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIndoor Noise Level (Turbo\/Hi\/Med\/Lo\/Si) dB(A)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e54.5 \/ 49.5 \/ 43.5 \/ 34.5 \/ 20.5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimension (W×D×H) (in)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e42.60 × 9.21 × 13.27\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePacking (W×D×H) (in)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e45.47 × 12.40 × 16.34\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNet\/Gross Weight (lb)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e30.86 \/ 40.56\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRoom Temperature (Cooling) (°F)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e60–90\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRoom Temperature (Heating) (°F)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e32–86\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRefrigerant piping Liquid\/Gas side (inch)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3\/8\" \/ 5\/8\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"hvx-desc-card\"\u003e\n\u003ch2 class=\"hvx-section-title\"\u003eOutdoor Specs\u003c\/h2\u003e\n\u003cdiv class=\"hvx-table-wrap\"\u003e\n\u003ctable class=\"hvx-table\" aria-label=\"Outdoor unit specifications\"\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eSpec\u003c\/th\u003e\n\u003cth\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCH-RHP24-230VO\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRefrigerant type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eR454B\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBTU Rated\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e24,000\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower source\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e208-230V, 1Ph, 60Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eVoltage range (V)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e187-253\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRefrigerant piping Liquid\/Gas side (inch)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3\/8\" \/ 5\/8\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMax. pipe length (ft)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e164\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMax height difference between Indoor and Outdoor unit\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e82\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCooling capacity (Min\/Max) (BTU\/h)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e24,000 (12,600~27,900)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eHeating capacity (Min\/Max) (Btu\/h)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e29,000 (11,800~29,700)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eHSPF2-5\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e9.8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eHSPF2-4\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e13.5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCOP\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3.42\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDehumidification value (pnt\/day)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e5.71\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOutdoor Noise Level\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e61.5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOutdoor Air Flow\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2,235.3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMinimum circuit ampacity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e24.9\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMax.fuse\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e25\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAmbient temperature - Heating (F)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-22~75\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAmbient temperature - Cooling (F)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-22 ~ 122\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eUnit dimensions (W*H*D)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e37.24 x 16.14 x 31.89\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eUnit Net\/Gross weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e130.29\/141.31\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePacking dimensions (WxDxH)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e42.91 x 19.68 x 34.84\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRefrigerant precharge\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e25\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAdditional Refrigerant Charge 3\/8 liquid line\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.32\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"hvx-desc-card\"\u003e\n\u003ch2 class=\"hvx-section-title\"\u003eDocuments \u0026amp; Downloads\u003c\/h2\u003e\n\u003cul style=\"padding-left: 18px; margin: 8px 0;\"\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/media.cooperandhunter.us\/4730\/CH-RES24-230VO_CH-R24MOLVWM-230VI.pdf\" rel=\"noopener\" target=\"_blank\"\u003eSubmittal (PDF): CH-R24MOLVWM-230VI (Link 1)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca class=\"hvx-link\" href=\"https:\/\/drive.google.com\/file\/d\/11uCRDvBhIcMpwvzipwSXF-SzHNnvy1ty\/view?usp=drive_link\" rel=\"noopener\" target=\"_blank\"\u003eSubmittal (PDF): CH-R24MOLVWM-230VI (Link 2)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca class=\"hvx-link\" href=\"https:\/\/media.cooperandhunter.us\/3959\/CH-RHP24-230VO-%2B-CH-RS24MAHU.pdf\" rel=\"noopener\" target=\"_blank\"\u003eSubmittal (PDF): CH-RHP24-230VO + CH-RS24MAHU\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca class=\"hvx-link\" href=\"https:\/\/media.cooperandhunter.us\/4160\/CH-RHP24-230VO-%2B-CH-PRO24MASTWM-230VI.pdf\" rel=\"noopener\" target=\"_blank\"\u003eSubmittal (PDF): CH-RHP24-230VO + CH-PRO24MASTWM-230VI\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca class=\"hvx-link\" href=\"https:\/\/media.cooperandhunter.us\/4174\/CH-RHP24-230VO-%2B-CH-RH24MASTWM-230VI.pdf\" rel=\"noopener\" target=\"_blank\"\u003eSubmittal (PDF): CH-RHP24-230VO + CH-RH24MASTWM-230VI\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca class=\"hvx-link\" href=\"https:\/\/media.cooperandhunter.us\/4205\/CH-RHP24-230VO-%2B-CH-RS24MDT-HS.pdf\" rel=\"noopener\" target=\"_blank\"\u003eSubmittal (PDF): CH-RHP24-230VO + CH-RS24MDT-HS\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca class=\"hvx-link\" href=\"https:\/\/media.cooperandhunter.us\/4631\/CH-RHP24-230VO_CH-RSH24MFC.pdf\" rel=\"noopener\" target=\"_blank\"\u003eSubmittal (PDF): CH-RHP24-230VO + CH-RSH24MFC\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca class=\"hvx-link\" href=\"https:\/\/media.cooperandhunter.us\/4688\/CH-RHP24-230VO_CH-RH24MCT.pdf\" rel=\"noopener\" target=\"_blank\"\u003eSubmittal (PDF): CH-RHP24-230VO + CH-RH24MCT\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca class=\"hvx-link\" href=\"https:\/\/media.cooperandhunter.us\/4118\/Installation-Manual-R454B-Outdoor-units--.pdf\" rel=\"noopener\" target=\"_blank\"\u003eInstallation Manual (PDF): R454B Outdoor Units\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca class=\"hvx-link\" href=\"https:\/\/media.cooperandhunter.us\/4200\/SlimDuct-Leaflet-R454B.pdf\" rel=\"noopener\" target=\"_blank\"\u003eLeaflet (PDF): SlimDuct — R454B\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca class=\"hvx-link\" href=\"https:\/\/cooperandhunter.us\/product\/ch-rhp24-230vo\" rel=\"noopener\" target=\"_blank\"\u003eManufacturer Page: CH-RHP24-230VO\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca class=\"hvx-link\" href=\"https:\/\/www.ahridirectory.org\" rel=\"noopener\" target=\"_blank\"\u003eAHRI Directory Listing: 207742320\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"hvx-desc-card\"\u003e\n\u003ch2 class=\"hvx-section-title\"\u003eImportant\u003c\/h2\u003e\n\u003cp style=\"margin: 0; font-size: 14px; color: var(--hvx-slate);\"\u003eProfessional installation is recommended. Confirm electrical requirements, line sizes, maximum line length, and ambient operating limits before installation.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"hvx-desc-card\"\u003e\n\u003ch2 class=\"hvx-section-title\"\u003eFAQs\u003c\/h2\u003e\n\u003cdetails class=\"hvx-faq\" open=\"\"\u003e\n\u003csummary\u003eIs this system Hyper Heat?\u003c\/summary\u003e\n\u003cdiv style=\"margin-top: 8px;\"\u003eYes—Hyper Heating operation is rated down to −22°F.\u003c\/div\u003e\n\u003c\/details\u003e\n\u003cdetails class=\"hvx-faq\" open=\"\"\u003e\n\u003csummary\u003eWhat line sizes does this system use?\u003c\/summary\u003e\n\u003cdiv style=\"margin-top: 8px;\"\u003e3\/8\" liquid and 5\/8\" gas.\u003c\/div\u003e\n\u003c\/details\u003e\n\u003cdetails class=\"hvx-faq\" open=\"\"\u003e\n\u003csummary\u003eWhat is the maximum line set length?\u003c\/summary\u003e\n\u003cdiv style=\"margin-top: 8px;\"\u003eUp to 164 ft (maximum pipe length).\u003c\/div\u003e\n\u003c\/details\u003e\n\u003cdetails class=\"hvx-faq\" open=\"\"\u003e\n\u003csummary\u003eDoes it include smart control?\u003c\/summary\u003e\n\u003cdiv style=\"margin-top: 8px;\"\u003eYes—Smart Kit is included for C\u0026amp;H app control, and a remote is included.\u003c\/div\u003e\n\u003c\/details\u003e\n\u003cdetails class=\"hvx-faq\" open=\"\"\u003e\n\u003csummary\u003eIs a wall thermostat supported?\u003c\/summary\u003e\n\u003cdiv style=\"margin-top: 8px;\"\u003eYes—wall thermostat compatibility is available (thermostat sold separately).\u003c\/div\u003e\n\u003c\/details\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e","brand":"Cooper\u0026Hunter","offers":[{"title":"No installation","offer_id":42690239922219,"sku":"CH-RB24MOLVWM-230VI + CH-RHP24-230VO","price":2344.0,"currency_code":"USD","in_stock":true},{"title":"16FT","offer_id":42690239954987,"sku":"CH-RB24MOLVWM-230VI + CH-RHP24-230VO","price":2560.0,"currency_code":"USD","in_stock":true},{"title":"25FT","offer_id":42690239987755,"sku":"CH-RB24MOLVWM-230VI + CH-RHP24-230VO","price":2689.0,"currency_code":"USD","in_stock":true},{"title":"50FT","offer_id":42690240020523,"sku":"CH-RB24MOLVWM-230VI + CH-RHP24-230VO","price":2996.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0625\/5647\/1339\/files\/12_b44b24b4-03fa-4830-8afc-e22e19e71fbe.png?v=1769199597"},{"product_id":"cooper-hunter-9-000-btu-olivia-midnight-single-zone-wall-mount-minisplit-heat-pump-system-r454b-230v","title":"Cooper\u0026Hunter 9,000 BTU Olivia Midnight Single Zone Wall Mount Minisplit Heat Pump System R454B 230V","description":"\u003cstyle\u003e\n  :root{\n    --hvx-golden:#FAA819;\n    --hvx-slate:#262626;\n    --hvx-ivory:#F4F1E6;\n    --hvx-border:#e2e0d5;\n    --hvx-card-bg:#ffffff;\n  }\n\n  .hvx-desc{\n    font-family:\"Articulat CF\",system-ui,-apple-system,BlinkMacSystemFont,\"Segoe UI\",sans-serif;\n    color:var(--hvx-slate);\n    line-height:1.6;\n    background:var(--hvx-ivory);\n    padding:18px 18px 20px;\n    border-radius:16px;\n  }\n\n  .hvx-desc-header{\n    border-radius:14px;\n    padding:14px 16px;\n    background:linear-gradient(120deg,var(--hvx-golden),var(--hvx-slate));\n    color:#fff;\n    margin:0 0 16px;\n    box-shadow:0 10px 24px rgba(0,0,0,.22);\n    display:flex;\n    align-items:flex-start;\n    gap:12px;\n    flex-wrap:wrap;\n  }\n\n  .hvx-header-text{display:flex;flex-direction:column;gap:6px;min-width:260px}\n  .hvx-eyebrow{\n    font-size:11px;\n    letter-spacing:.14em;\n    text-transform:uppercase;\n    opacity:.9;\n  }\n  .hvx-title{\n    margin:0;\n    font-family:\"Anton\",\"Impact\",system-ui,-apple-system,BlinkMacSystemFont,\"Segoe UI\",sans-serif;\n    font-size:22px;\n    line-height:1.15;\n  }\n  .hvx-subtitle{margin:0;font-size:14px;opacity:.95}\n\n  .hvx-desc-card{\n    border:1px solid var(--hvx-border);\n    border-radius:14px;\n    background:var(--hvx-card-bg);\n    padding:16px 18px 18px;\n    box-shadow:0 4px 12px rgba(0,0,0,.06);\n    margin:14px 0;\n  }\n\n  .hvx-section-title{\n    margin:0 0 10px;\n    font-family:\"Anton\",\"Impact\",system-ui,-apple-system,BlinkMacSystemFont,\"Segoe UI\",sans-serif;\n    font-size:17px;\n    letter-spacing:.08em;\n    text-transform:uppercase;\n    color:var(--hvx-slate);\n    display:inline-flex;\n    align-items:center;\n    gap:8px;\n  }\n  .hvx-section-title::after{\n    content:\"\";\n    flex:1;\n    height:2px;\n    border-radius:999px;\n    background:linear-gradient(90deg,var(--hvx-golden),transparent);\n    opacity:.9;\n  }\n\n  .hvx-cta{display:flex;flex-wrap:wrap;gap:10px;margin:10px 0 0}\n  .hvx-cta a{\n    display:inline-flex;\n    align-items:center;\n    gap:8px;\n    padding:10px 14px;\n    border-radius:12px;\n    border:1px solid var(--hvx-border);\n    background:#fff;\n    text-decoration:none;\n    color:var(--hvx-slate);\n    font-size:14px;\n    font-weight:700;\n  }\n  .hvx-cta a.primary{\n    background:var(--hvx-slate);\n    color:#fff;\n    border-color:transparent;\n  }\n\n  .hvx-badges{display:flex;flex-wrap:wrap;gap:8px;margin:10px 0 0}\n  .hvx-badge{\n    font-size:12px;\n    border:1px solid var(--hvx-border);\n    border-radius:999px;\n    padding:6px 10px;\n    background:#fff;\n    white-space:nowrap;\n  }\n\n  .hvx-kv{\n    display:grid;\n    grid-template-columns:repeat(4,minmax(160px,1fr));\n    gap:10px;\n    margin-top:10px;\n  }\n  .hvx-kv \u003e div{\n    border:1px solid var(--hvx-border);\n    background:#fff;\n    border-radius:12px;\n    padding:10px 12px;\n    text-align:center;\n  }\n  .hvx-kv strong{display:block}\n\n  .hvx-table{\n    width:100%;\n    border-collapse:collapse;\n    min-width:520px;\n    background:#fff;\n    border:1px solid var(--hvx-border);\n    border-radius:12px;\n    overflow:hidden;\n  }\n  .hvx-table th,.hvx-table td{\n    border-bottom:1px solid var(--hvx-border);\n    padding:10px 12px;\n    vertical-align:top;\n    font-size:14px;\n  }\n  .hvx-table th{ text-align:left; font-weight:800; background:#fff; }\n  .hvx-table tr:nth-child(even) td{ background:#fbfaf6; }\n  .hvx-table tr:last-child td{ border-bottom:none; }\n  .hvx-table-wrap{ overflow:auto; border-radius:12px; }\n\n  .hvx-link{color:var(--hvx-slate); text-decoration:underline; text-underline-offset:2px}\n  .hvx-link:hover{opacity:.85}\n\n  details.hvx-faq{\n    border:1px solid var(--hvx-border);\n    background:#fff;\n    border-radius:12px;\n    padding:10px 12px;\n    margin:8px 0;\n  }\n  details.hvx-faq summary{cursor:pointer;font-weight:800}\n\n  @media(max-width:980px){\n    .hvx-kv{grid-template-columns:repeat(2,minmax(160px,1fr))}\n  }\n  @media(max-width:768px){\n    .hvx-desc{padding:14px 12px 16px;border-radius:12px}\n    .hvx-desc-header{padding:12px;border-radius:12px}\n    .hvx-title{font-size:19px}\n    .hvx-desc-card{padding:14px;margin:10px 0}\n  }\n\u003c\/style\u003e\n\n\u003cdiv class=\"hvx-desc\"\u003e\n  \u003cdiv class=\"hvx-desc-header\"\u003e\n    \u003cdiv class=\"hvx-header-text\"\u003e\n      \u003cdiv class=\"hvx-eyebrow\"\u003eCooper\u0026amp;Hunter Olivia Midnight • Black • R454B • 230V\u003c\/div\u003e\n      \u003ch1 class=\"hvx-title\"\u003eCooper\u0026amp;Hunter 9,000 BTU Olivia Midnight Single Zone Wall Mount Mini Split Heat Pump System R454B 230V\u003c\/h1\u003e\n      \u003cp class=\"hvx-subtitle\"\u003e\u003cstrong\u003eSKU:\u003c\/strong\u003e CH-RB09MOLVWM-230VI + CH-RES09-230VO\u003c\/p\u003e\n    \u003c\/div\u003e\n  \u003c\/div\u003e\n\n  \u003cdiv class=\"hvx-cta\" aria-label=\"Contact options\"\u003e\n    \u003ca class=\"primary\" href=\"https:\/\/hvacsupplies.com\/pages\/contact\" rel=\"noopener\" title=\"Contact Us\" target=\"_blank\"\u003e\n      CLICK HERE TO CONTACT US FOR CUSTOM QUOTES AND QUESTIONS\n    \u003c\/a\u003e\n    \u003ca href=\"tel:+18005438933\" title=\"Call Us Now!\"\u003e\n      CLICK TO CALL US 800-543-8933 FOR ANY QUESTIONS\n    \u003c\/a\u003e\n  \u003c\/div\u003e\n\n  \u003cdiv class=\"hvx-desc-card\"\u003e\n    \u003ch2 class=\"hvx-section-title\"\u003eOverview\u003c\/h2\u003e\n    \u003cp style=\"margin: 0;\"\u003e\n      Transform your home’s climate control with the Cooper\u0026amp;Hunter \u003cstrong\u003e9K BTU Olivia Midnight\u003c\/strong\u003e wall-mounted mini split system,\n      featuring the new \u003cstrong\u003eR454B refrigerant\u003c\/strong\u003e and an elegant \u003cstrong\u003eblack\u003c\/strong\u003e indoor unit for a modern, premium look. Designed for\n      \u003cstrong\u003e208–230V\u003c\/strong\u003e installations, Olivia Midnight combines advanced comfort features with efficient performance (up to \u003cstrong\u003e26.4 SEER2\u003c\/strong\u003e per provided indoor data).\n    \u003c\/p\u003e\n    \u003cp style=\"margin: 10px 0 0;\"\u003e\n      Comfort and convenience features include \u003cstrong\u003eAuto-Swing\u003c\/strong\u003e horizontal louvers for improved air circulation, \u003cstrong\u003eTurbo Mode\u003c\/strong\u003e for rapid heating\/cooling,\n      \u003cstrong\u003eFollow Me\u003c\/strong\u003e sensing from the remote, \u003cstrong\u003eTimer On\/Off\u003c\/strong\u003e and \u003cstrong\u003eSleep Mode\u003c\/strong\u003e, plus \u003cstrong\u003e46° Freeze Protection\u003c\/strong\u003e.\n      Advanced technology includes \u003cstrong\u003e12Hz\u003c\/strong\u003e ultra-low compressor speed for quiet efficiency, \u003cstrong\u003eHigh-Frequency Racer Technology\u003c\/strong\u003e for fast startup response,\n      an \u003cstrong\u003eelectronic expansion valve\u003c\/strong\u003e for optimized refrigerant flow management, and an \u003cstrong\u003eintelligent dusting switch\u003c\/strong\u003e that reverses the fan to help clear dust,\n      sand, and debris from the coil. Built with \u003cstrong\u003eTU1 copper tubes\u003c\/strong\u003e for durability and efficient heat transfer.\n    \u003c\/p\u003e\n    \u003cp style=\"margin: 10px 0 0;\"\u003e\n      The Regular single-zone outdoor unit uses advanced inverter control to precisely match heating\/cooling demand while helping reduce energy use.\n    \u003c\/p\u003e\n  \u003c\/div\u003e\n\n  \u003cdiv class=\"hvx-desc-card\"\u003e\n    \u003ch2 class=\"hvx-section-title\"\u003eHighlights\u003c\/h2\u003e\n\n    \u003cdiv class=\"hvx-badges\" role=\"list\"\u003e\n      \u003cspan class=\"hvx-badge\" role=\"listitem\"\u003e9,000 BTU class\u003c\/span\u003e\n      \u003cspan class=\"hvx-badge\" role=\"listitem\"\u003eOlivia Midnight (Black indoor)\u003c\/span\u003e\n      \u003cspan class=\"hvx-badge\" role=\"listitem\"\u003eR454B refrigerant\u003c\/span\u003e\n      \u003cspan class=\"hvx-badge\" role=\"listitem\"\u003eSEER2 26.4 (Indoor data)\u003c\/span\u003e\n      \u003cspan class=\"hvx-badge\" role=\"listitem\"\u003eEER2 15.8 (Indoor data)\u003c\/span\u003e\n      \u003cspan class=\"hvx-badge\" role=\"listitem\"\u003eInverter-driven performance\u003c\/span\u003e\n      \u003cspan class=\"hvx-badge\" role=\"listitem\"\u003eSmart Kit included\u003c\/span\u003e\n      \u003cspan class=\"hvx-badge\" role=\"listitem\"\u003eAuto-swing (horizontal louvers)\u003c\/span\u003e\n      \u003cspan class=\"hvx-badge\" role=\"listitem\"\u003e208–230V, 1Ph, 60Hz\u003c\/span\u003e\n      \u003cspan class=\"hvx-badge\" role=\"listitem\"\u003eSingle \/ Multi-zone capable indoor\u003c\/span\u003e\n    \u003c\/div\u003e\n\n    \u003cul style=\"margin: 12px 0 0; padding-left: 18px;\"\u003e\n      \u003cli\u003e\n\u003cstrong\u003eEven air distribution:\u003c\/strong\u003e Auto-Swing louvers help reduce hot\/cold spots.\u003c\/li\u003e\n      \u003cli\u003e\n\u003cstrong\u003eFast comfort:\u003c\/strong\u003e Turbo Mode and rapid startup response for quick temperature changes.\u003c\/li\u003e\n      \u003cli\u003e\n\u003cstrong\u003ePersonalized control:\u003c\/strong\u003e Follow Me adjusts temperature based on remote sensor location.\u003c\/li\u003e\n      \u003cli\u003e\n\u003cstrong\u003eSmart control ready:\u003c\/strong\u003e Smart Kit enables app connectivity and remote control.\u003c\/li\u003e\n      \u003cli\u003e\n\u003cstrong\u003eControl options:\u003c\/strong\u003e Remote included; wall thermostat optional (sold separately).\u003c\/li\u003e\n    \u003c\/ul\u003e\n\n    \u003cdiv class=\"hvx-kv\" role=\"list\" aria-label=\"At-a-glance\"\u003e\n      \u003cdiv role=\"listitem\"\u003e\n\u003cstrong\u003eIndoor\u003c\/strong\u003eCH-RB09MOLVWM-230VI\u003c\/div\u003e\n      \u003cdiv role=\"listitem\"\u003e\n\u003cstrong\u003eOutdoor\u003c\/strong\u003eCH-RES09-230VO\u003c\/div\u003e\n      \u003cdiv role=\"listitem\"\u003e\n\u003cstrong\u003eLines\u003c\/strong\u003e1\/4\" liquid · 3\/8\" gas\u003c\/div\u003e\n      \u003cdiv role=\"listitem\"\u003e\n\u003cstrong\u003eMax run\u003c\/strong\u003e82 ft\u003c\/div\u003e\n    \u003c\/div\u003e\n  \u003c\/div\u003e\n\n  \u003cdiv class=\"hvx-desc-card\"\u003e\n    \u003ch2 class=\"hvx-section-title\"\u003eWhat’s Included\u003c\/h2\u003e\n    \u003cul style=\"padding-left: 18px; margin: 8px 0;\"\u003e\n      \u003cli\u003eIndoor unit: CH-RB09MOLVWM-230VI (Olivia Midnight Black)\u003c\/li\u003e\n      \u003cli\u003eOutdoor unit: CH-RES09-230VO (Regular)\u003c\/li\u003e\n      \u003cli\u003eRemote control (included)\u003c\/li\u003e\n      \u003cli\u003eSmart Kit for app control\u003c\/li\u003e\n      \u003cli\u003eManufacturer documentation (see Documents \u0026amp; Downloads)\u003c\/li\u003e\n    \u003c\/ul\u003e\n  \u003c\/div\u003e\n\n  \u003cdiv class=\"hvx-desc-card\"\u003e\n    \u003ch2 class=\"hvx-section-title\"\u003eIndoor Specs\u003c\/h2\u003e\n    \u003cdiv class=\"hvx-table-wrap\"\u003e\n      \u003ctable class=\"hvx-table\" aria-label=\"Indoor unit specifications\"\u003e\n        \u003cthead\u003e\n          \u003ctr\u003e\n\u003cth\u003eSpec\u003c\/th\u003e\n\u003cth\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\n        \u003c\/thead\u003e\n        \u003ctbody\u003e\n          \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCH-RB09MOLVWM-230VI\u003c\/td\u003e\n\u003c\/tr\u003e\n          \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated V-Ph-Hz\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e208\/230, 1, 60\u003c\/td\u003e\n\u003c\/tr\u003e\n          \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated capacity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e9,000 BTU\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n          \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSEER2\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e26.4\u003c\/td\u003e\n\u003c\/tr\u003e\n          \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEER2\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e15.8\u003c\/td\u003e\n\u003c\/tr\u003e\n          \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMinimum circuit ampacity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003c\/tr\u003e\n          \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMax fuse\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e15\u003c\/td\u003e\n\u003c\/tr\u003e\n          \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRefrigerant piping (liq\/gas)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1\/4\" \/ 3\/8\"\u003c\/td\u003e\n\u003c\/tr\u003e\n          \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIndoor air flow\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e341.18 \/ 291.18 \/ 194.12 \/ 152.94\u003c\/td\u003e\n\u003c\/tr\u003e\n          \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIndoor noise level (H\/M\/L)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e40 \/ 34 \/ 23.5\u003c\/td\u003e\n\u003c\/tr\u003e\n          \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIndoor noise level (Turbo\/Hi\/Mi\/Lo\/Si)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e45.5 \/ 42 \/ 36 \/ 21 \/ 19.5\u003c\/td\u003e\n\u003c\/tr\u003e\n          \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eUnit dimensions (W×D×H)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e31.57 × 7.87 × 11.61\u003c\/td\u003e\n\u003c\/tr\u003e\n          \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePacking dimensions (W×D×H)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e34.45 × 11.22 × 14.96\u003c\/td\u003e\n\u003c\/tr\u003e\n          \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNet \/ Gross weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e18.96 \/ 24.25\u003c\/td\u003e\n\u003c\/tr\u003e\n          \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating range (Cooling)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e60–90\u003c\/td\u003e\n\u003c\/tr\u003e\n          \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating range (Heating)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e32–86\u003c\/td\u003e\n\u003c\/tr\u003e\n          \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDrainage water pipe diameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e5\/8\"\u003c\/td\u003e\n\u003c\/tr\u003e\n        \u003c\/tbody\u003e\n      \u003c\/table\u003e\n    \u003c\/div\u003e\n  \u003c\/div\u003e\n\n  \u003cdiv class=\"hvx-desc-card\"\u003e\n    \u003ch2 class=\"hvx-section-title\"\u003eOutdoor Specs\u003c\/h2\u003e\n    \u003cdiv class=\"hvx-table-wrap\"\u003e\n      \u003ctable class=\"hvx-table\" aria-label=\"Outdoor unit specifications\"\u003e\n        \u003cthead\u003e\n          \u003ctr\u003e\n\u003cth\u003eSpec\u003c\/th\u003e\n\u003cth\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\n        \u003c\/thead\u003e\n        \u003ctbody\u003e\n          \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCH-RES09-230VO\u003c\/td\u003e\n\u003c\/tr\u003e\n          \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSystem type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSingle-zone unit\u003c\/td\u003e\n\u003c\/tr\u003e\n          \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRefrigerant type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eR454B\u003c\/td\u003e\n\u003c\/tr\u003e\n          \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBTU rated\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e9,000\u003c\/td\u003e\n\u003c\/tr\u003e\n          \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower source\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e208–230V, 1Ph, 60Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n          \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eVoltage range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e187–253 V\u003c\/td\u003e\n\u003c\/tr\u003e\n          \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRefrigerant piping (liq\/gas)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1\/4\" \/ 3\/8\"\u003c\/td\u003e\n\u003c\/tr\u003e\n          \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMax pipe length\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e82 ft\u003c\/td\u003e\n\u003c\/tr\u003e\n          \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMax height difference (IDU↔ODU)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e49.2\u003c\/td\u003e\n\u003c\/tr\u003e\n          \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCooling capacity (Min\/Max)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e9,000 (3,100~11,900)\u003c\/td\u003e\n\u003c\/tr\u003e\n          \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eHeating capacity (Min\/Max)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e10,000 (3,600~14,000)\u003c\/td\u003e\n\u003c\/tr\u003e\n          \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSEER2\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e19.5\u003c\/td\u003e\n\u003c\/tr\u003e\n          \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEER2\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e12.8\u003c\/td\u003e\n\u003c\/tr\u003e\n          \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eHSPF2-5\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e8.8\u003c\/td\u003e\n\u003c\/tr\u003e\n          \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eHSPF2-4\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e11\u003c\/td\u003e\n\u003c\/tr\u003e\n          \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCOP\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3.66\u003c\/td\u003e\n\u003c\/tr\u003e\n          \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDehumidification\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1.44 pnt\/day\u003c\/td\u003e\n\u003c\/tr\u003e\n          \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOutdoor noise level\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e54\u003c\/td\u003e\n\u003c\/tr\u003e\n          \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOutdoor air flow\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1,236.1\u003c\/td\u003e\n\u003c\/tr\u003e\n          \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMinimum circuit ampacity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e12\u003c\/td\u003e\n\u003c\/tr\u003e\n          \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMax fuse\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e15\u003c\/td\u003e\n\u003c\/tr\u003e\n          \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAmbient temp (Heating)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e−13~75\u003c\/td\u003e\n\u003c\/tr\u003e\n          \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAmbient temp (Cooling)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e−13~122\u003c\/td\u003e\n\u003c\/tr\u003e\n          \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eUnit dimensions (W×H×D)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e30.12 × 11.93 × 21.85\u003c\/td\u003e\n\u003c\/tr\u003e\n          \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNet \/ Gross weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e62.17 \/ 67.68\u003c\/td\u003e\n\u003c\/tr\u003e\n          \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePacking dimensions (W×D×H)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e34.92 × 13.27 × 24.02\u003c\/td\u003e\n\u003c\/tr\u003e\n          \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRefrigerant precharge\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e25\u003c\/td\u003e\n\u003c\/tr\u003e\n          \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAdditional charge (1\/4\" liquid)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.16\u003c\/td\u003e\n\u003c\/tr\u003e\n        \u003c\/tbody\u003e\n      \u003c\/table\u003e\n    \u003c\/div\u003e\n  \u003c\/div\u003e\n\n  \u003cdiv class=\"hvx-desc-card\"\u003e\n    \u003ch2 class=\"hvx-section-title\"\u003eDocuments \u0026amp; Downloads\u003c\/h2\u003e\n    \u003cul style=\"padding-left: 18px; margin: 8px 0;\"\u003e\n      \u003cli\u003e\u003ca class=\"hvx-link\" href=\"https:\/\/media.cooperandhunter.us\/4952\/CH-RES09-230VO-_-CH-RB09MOLVWM-230VI.pdf\" rel=\"noopener\" target=\"_blank\"\u003eSubmittal (PDF) — CH-RES09-230VO + CH-RB09MOLVWM-230VI\u003c\/a\u003e\u003c\/li\u003e\n      \u003cli\u003e\u003ca class=\"hvx-link\" href=\"https:\/\/media.cooperandhunter.us\/4958\/CH-RHP09-230VO_CH-RB09MOLVWM-230VI.pdf\" rel=\"noopener\" target=\"_blank\"\u003eSubmittal (PDF) — CH-RHP09-230VO + CH-RB09MOLVWM-230VI\u003c\/a\u003e\u003c\/li\u003e\n      \u003cli\u003e\u003ca class=\"hvx-link\" href=\"https:\/\/media.cooperandhunter.us\/4962\/CH-RB09MOLVWM-230VI.pdf\" rel=\"noopener\" target=\"_blank\"\u003eSubmittal (PDF) — CH-RB09MOLVWM-230VI\u003c\/a\u003e\u003c\/li\u003e\n\n      \u003cli\u003e\u003ca class=\"hvx-link\" href=\"https:\/\/media.cooperandhunter.us\/4166\/CH-RES09-230VO-%2B-CH-RH09MASTWM-230VI.pdf\" rel=\"noopener\" target=\"_blank\"\u003eSubmittal (PDF) — CH-RES09-230VO + CH-RH09MASTWM-230VI\u003c\/a\u003e\u003c\/li\u003e\n      \u003cli\u003e\u003ca class=\"hvx-link\" href=\"https:\/\/media.cooperandhunter.us\/4164\/CH-RES09-230VO-%2B-CH-PRO09MASTWM-230VI.pdf\" rel=\"noopener\" target=\"_blank\"\u003eSubmittal (PDF) — CH-RES09-230VO + CH-PRO09MASTWM-230VI\u003c\/a\u003e\u003c\/li\u003e\n      \u003cli\u003e\u003ca class=\"hvx-link\" href=\"https:\/\/media.cooperandhunter.us\/4209\/CH-RES09-230VO-%2B-CH-RS06-12MDT--MS.pdf\" rel=\"noopener\" target=\"_blank\"\u003eSubmittal (PDF) — CH-RES09-230VO + CH-RS06-12MDT-MS\u003c\/a\u003e\u003c\/li\u003e\n      \u003cli\u003e\u003ca class=\"hvx-link\" href=\"https:\/\/media.cooperandhunter.us\/4675\/CH-RES09-230VO_CH-RH09MCT.pdf\" rel=\"noopener\" target=\"_blank\"\u003eSubmittal (PDF) — CH-RES09-230VO + CH-RH09MCT\u003c\/a\u003e\u003c\/li\u003e\n      \u003cli\u003e\u003ca class=\"hvx-link\" href=\"https:\/\/media.cooperandhunter.us\/4674\/CH-RES09-230VO_CH-RSH09MCT.pdf\" rel=\"noopener\" target=\"_blank\"\u003eSubmittal (PDF) — CH-RES09-230VO + CH-RSH09MCT\u003c\/a\u003e\u003c\/li\u003e\n\n      \u003cli\u003e\u003ca class=\"hvx-link\" href=\"https:\/\/media.cooperandhunter.us\/4118\/Installation-Manual-R454B-Outdoor-units--.pdf\" rel=\"noopener\" target=\"_blank\"\u003eInstallation Manual (PDF) — R454B Outdoor Units\u003c\/a\u003e\u003c\/li\u003e\n      \u003cli\u003e\u003ca class=\"hvx-link\" href=\"https:\/\/media.cooperandhunter.us\/4200\/SlimDuct-Leaflet-R454B.pdf\" rel=\"\n\"\u003e\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e","brand":"Cooper\u0026Hunter","offers":[{"title":"No installation","offer_id":42690241658923,"sku":"CH-RB09MOLVWM-230VI + CH-RES09-230VO","price":1114.0,"currency_code":"USD","in_stock":true},{"title":"16FT","offer_id":42690241691691,"sku":"CH-RB09MOLVWM-230VI + CH-RES09-230VO","price":1296.0,"currency_code":"USD","in_stock":true},{"title":"25FT","offer_id":42690241724459,"sku":"CH-RB09MOLVWM-230VI + CH-RES09-230VO","price":1342.0,"currency_code":"USD","in_stock":true},{"title":"50FT","offer_id":42690241757227,"sku":"CH-RB09MOLVWM-230VI + CH-RES09-230VO","price":1562.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0625\/5647\/1339\/files\/Midnight_Bundle_1_1_e4edcfca-3bd5-4b28-88ee-89dc2ad3d459.jpg?v=1769199500"},{"product_id":"cooper-hunter-12-000-btu-olivia-midnight-single-zone-wall-mount-minisplit-heat-pump-system-r454b-230v","title":"Cooper\u0026Hunter 12,000 BTU Olivia Midnight Single Zone Wall Mount Minisplit Heat Pump System R454B 230V","description":"\u003cstyle\u003e\n  :root{\n    --hvx-golden:#FAA819;\n    --hvx-slate:#262626;\n    --hvx-ivory:#F4F1E6;\n    --hvx-border:#e2e0d5;\n    --hvx-card-bg:#ffffff;\n  }\n\n  .hvx-desc{\n    font-family:\"Articulat CF\",system-ui,-apple-system,BlinkMacSystemFont,\"Segoe UI\",sans-serif;\n    color:var(--hvx-slate);\n    line-height:1.6;\n    background:var(--hvx-ivory);\n    padding:18px 18px 20px;\n    border-radius:16px;\n  }\n\n  .hvx-desc-header{\n    border-radius:14px;\n    padding:14px 16px;\n    background:linear-gradient(120deg,var(--hvx-golden),var(--hvx-slate));\n    color:#fff;\n    margin:0 0 16px;\n    box-shadow:0 10px 24px rgba(0,0,0,.22);\n    display:flex;\n    align-items:flex-start;\n    gap:12px;\n    flex-wrap:wrap;\n  }\n\n  .hvx-header-text{display:flex;flex-direction:column;gap:6px;min-width:260px}\n  .hvx-eyebrow{\n    font-size:11px;\n    letter-spacing:.14em;\n    text-transform:uppercase;\n    opacity:.9;\n  }\n  .hvx-title{\n    margin:0;\n    font-family:\"Anton\",\"Impact\",system-ui,-apple-system,BlinkMacSystemFont,\"Segoe UI\",sans-serif;\n    font-size:22px;\n    line-height:1.15;\n  }\n  .hvx-subtitle{margin:0;font-size:14px;opacity:.95}\n\n  .hvx-desc-card{\n    border:1px solid var(--hvx-border);\n    border-radius:14px;\n    background:var(--hvx-card-bg);\n    padding:16px 18px 18px;\n    box-shadow:0 4px 12px rgba(0,0,0,.06);\n    margin:14px 0;\n  }\n\n  .hvx-section-title{\n    margin:0 0 10px;\n    font-family:\"Anton\",\"Impact\",system-ui,-apple-system,BlinkMacSystemFont,\"Segoe UI\",sans-serif;\n    font-size:17px;\n    letter-spacing:.08em;\n    text-transform:uppercase;\n    color:var(--hvx-slate);\n    display:inline-flex;\n    align-items:center;\n    gap:8px;\n  }\n  .hvx-section-title::after{\n    content:\"\";\n    flex:1;\n    height:2px;\n    border-radius:999px;\n    background:linear-gradient(90deg,var(--hvx-golden),transparent);\n    opacity:.9;\n  }\n\n  .hvx-cta{display:flex;flex-wrap:wrap;gap:10px;margin:10px 0 0}\n  .hvx-cta a{\n    display:inline-flex;\n    align-items:center;\n    gap:8px;\n    padding:10px 14px;\n    border-radius:12px;\n    border:1px solid var(--hvx-border);\n    background:#fff;\n    text-decoration:none;\n    color:var(--hvx-slate);\n    font-size:14px;\n    font-weight:700;\n  }\n  .hvx-cta a.primary{\n    background:var(--hvx-slate);\n    color:#fff;\n    border-color:transparent;\n  }\n\n  .hvx-badges{display:flex;flex-wrap:wrap;gap:8px;margin:10px 0 0}\n  .hvx-badge{\n    font-size:12px;\n    border:1px solid var(--hvx-border);\n    border-radius:999px;\n    padding:6px 10px;\n    background:#fff;\n    white-space:nowrap;\n  }\n\n  .hvx-kv{\n    display:grid;\n    grid-template-columns:repeat(4,minmax(160px,1fr));\n    gap:10px;\n    margin-top:10px;\n  }\n  .hvx-kv \u003e div{\n    border:1px solid var(--hvx-border);\n    background:#fff;\n    border-radius:12px;\n    padding:10px 12px;\n    text-align:center;\n  }\n  .hvx-kv strong{display:block}\n\n  .hvx-table{\n    width:100%;\n    border-collapse:collapse;\n    min-width:520px;\n    background:#fff;\n    border:1px solid var(--hvx-border);\n    border-radius:12px;\n    overflow:hidden;\n  }\n  .hvx-table th,.hvx-table td{\n    border-bottom:1px solid var(--hvx-border);\n    padding:10px 12px;\n    vertical-align:top;\n    font-size:14px;\n  }\n  .hvx-table th{ text-align:left; font-weight:800; background:#fff; }\n  .hvx-table tr:nth-child(even) td{ background:#fbfaf6; }\n  .hvx-table tr:last-child td{ border-bottom:none; }\n  .hvx-table-wrap{ overflow:auto; border-radius:12px; }\n\n  .hvx-link{color:var(--hvx-slate); text-decoration:underline; text-underline-offset:2px}\n  .hvx-link:hover{opacity:.85}\n\n  details.hvx-faq{\n    border:1px solid var(--hvx-border);\n    background:#fff;\n    border-radius:12px;\n    padding:10px 12px;\n    margin:8px 0;\n  }\n  details.hvx-faq summary{cursor:pointer;font-weight:800}\n\n  @media(max-width:980px){\n    .hvx-kv{grid-template-columns:repeat(2,minmax(160px,1fr))}\n  }\n  @media(max-width:768px){\n    .hvx-desc{padding:14px 12px 16px;border-radius:12px}\n    .hvx-desc-header{padding:12px;border-radius:12px}\n    .hvx-title{font-size:19px}\n    .hvx-desc-card{padding:14px;margin:10px 0}\n  }\n\u003c\/style\u003e\n\u003cdiv class=\"hvx-desc\"\u003e\n\u003cdiv class=\"hvx-desc-header\"\u003e\n\u003cdiv class=\"hvx-header-text\"\u003e\n\u003cdiv class=\"hvx-eyebrow\"\u003eCooper\u0026amp;Hunter Olivia Midnight • Black • R454B • 230V\u003c\/div\u003e\n\u003ch1 class=\"hvx-title\"\u003eCooper\u0026amp;Hunter 12,000 BTU Olivia Midnight Single Zone Wall Mount Mini Split Heat Pump System R454B 230V\u003c\/h1\u003e\n\u003cp class=\"hvx-subtitle\"\u003e\u003cstrong\u003eSKU:\u003c\/strong\u003e CH-RB12MOLVWM-230VI + CH-RES12-230VO\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"hvx-cta\" aria-label=\"Contact options\"\u003e\n\u003ca class=\"primary\" href=\"https:\/\/hvacsupplies.com\/pages\/contact\" rel=\"noopener\" title=\"Contact Us\" target=\"_blank\"\u003e CLICK HERE TO CONTACT US FOR CUSTOM QUOTES AND QUESTIONS \u003c\/a\u003e \u003ca href=\"tel:+18005438933\" title=\"Call Us Now!\"\u003e CLICK TO CALL US 800-543-8933 FOR ANY QUESTIONS \u003c\/a\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"hvx-desc-card\"\u003e\n\u003ch2 class=\"hvx-section-title\"\u003eOverview\u003c\/h2\u003e\n\u003cp style=\"margin: 0;\"\u003eTransform your home’s climate control with the Cooper\u0026amp;Hunter \u003cstrong\u003e12K BTU Olivia Midnight\u003c\/strong\u003e wall-mounted mini split system, featuring the new \u003cstrong\u003eR454B refrigerant\u003c\/strong\u003e and an elegant \u003cstrong\u003eblack\u003c\/strong\u003e indoor unit for a modern, premium look. Designed for \u003cstrong\u003e208–230V\u003c\/strong\u003e installations, Olivia Midnight combines advanced comfort features with efficient performance (up to \u003cstrong\u003e23.1 SEER2\u003c\/strong\u003e).\u003c\/p\u003e\n\u003cp style=\"margin: 10px 0 0;\"\u003eComfort and convenience features include \u003cstrong\u003eAuto-Swing\u003c\/strong\u003e horizontal louvers for improved air circulation, \u003cstrong\u003eTurbo Mode\u003c\/strong\u003e for rapid heating\/cooling, \u003cstrong\u003eFollow Me\u003c\/strong\u003e sensing from the remote, \u003cstrong\u003eTimer On\/Off\u003c\/strong\u003e and \u003cstrong\u003eSleep Mode\u003c\/strong\u003e, plus \u003cstrong\u003e46° Freeze Protection\u003c\/strong\u003e. Advanced technology includes \u003cstrong\u003e12Hz\u003c\/strong\u003e ultra-low compressor speed for quiet efficiency, \u003cstrong\u003eHigh-Frequency Racer Technology\u003c\/strong\u003e for fast startup response, an \u003cstrong\u003eelectronic expansion valve\u003c\/strong\u003e for optimized refrigerant flow management, and an \u003cstrong\u003eintelligent dusting switch\u003c\/strong\u003e that reverses the fan to help clear dust, sand, and debris from the coil. Built with \u003cstrong\u003eTU1 copper tubes\u003c\/strong\u003e for durability and efficient heat transfer.\u003c\/p\u003e\n\u003cp style=\"margin: 10px 0 0;\"\u003eThe Regular single-zone outdoor unit uses inverter control to closely match heating\/cooling demand while helping reduce energy use.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"hvx-desc-card\"\u003e\n\u003ch2 class=\"hvx-section-title\"\u003eHighlights\u003c\/h2\u003e\n\u003cdiv class=\"hvx-badges\" role=\"list\"\u003e\n\u003cspan class=\"hvx-badge\" role=\"listitem\"\u003e12,000 BTU class\u003c\/span\u003e \u003cspan class=\"hvx-badge\" role=\"listitem\"\u003eOlivia Midnight (Black indoor)\u003c\/span\u003e \u003cspan class=\"hvx-badge\" role=\"listitem\"\u003eR454B refrigerant\u003c\/span\u003e \u003cspan class=\"hvx-badge\" role=\"listitem\"\u003eSEER2 23.1 (Indoor)\u003c\/span\u003e \u003cspan class=\"hvx-badge\" role=\"listitem\"\u003eEER2 13.0 (Indoor)\u003c\/span\u003e \u003cspan class=\"hvx-badge\" role=\"listitem\"\u003eInverter-driven performance\u003c\/span\u003e \u003cspan class=\"hvx-badge\" role=\"listitem\"\u003eSmart Kit included\u003c\/span\u003e \u003cspan class=\"hvx-badge\" role=\"listitem\"\u003eAuto-swing (horizontal louvers)\u003c\/span\u003e \u003cspan class=\"hvx-badge\" role=\"listitem\"\u003e208–230V, 1Ph, 60Hz\u003c\/span\u003e \u003cspan class=\"hvx-badge\" role=\"listitem\"\u003eSingle \/ Multi-zone capable indoor\u003c\/span\u003e\n\u003c\/div\u003e\n\u003cul style=\"margin: 12px 0 0; padding-left: 18px;\"\u003e\n\u003cli\u003e\n\u003cstrong\u003eEven air distribution:\u003c\/strong\u003e Auto-Swing louvers help reduce hot\/cold spots.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFast comfort:\u003c\/strong\u003e Turbo Mode and rapid startup response for quick temperature changes.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePersonalized control:\u003c\/strong\u003e Follow Me adjusts temperature based on remote sensor location.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSmart control ready:\u003c\/strong\u003e Smart Kit enables app connectivity and remote control.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eControl options:\u003c\/strong\u003e Remote included; wall thermostat optional (sold separately).\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cdiv class=\"hvx-kv\" role=\"list\" aria-label=\"At-a-glance\"\u003e\n\u003cdiv role=\"listitem\"\u003e\n\u003cstrong\u003eIndoor\u003c\/strong\u003eCH-RB12MOLVWM-230VI\u003c\/div\u003e\n\u003cdiv role=\"listitem\"\u003e\n\u003cstrong\u003eOutdoor\u003c\/strong\u003eCH-RES12-230VO\u003c\/div\u003e\n\u003cdiv role=\"listitem\"\u003e\n\u003cstrong\u003eLines\u003c\/strong\u003e1\/4\" liquid · 3\/8\" gas\u003c\/div\u003e\n\u003cdiv role=\"listitem\"\u003e\n\u003cstrong\u003eMax run\u003c\/strong\u003e82 ft\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"hvx-desc-card\"\u003e\n\u003ch2 class=\"hvx-section-title\"\u003eWhat’s Included\u003c\/h2\u003e\n\u003cul style=\"padding-left: 18px; margin: 8px 0;\"\u003e\n\u003cli\u003eIndoor unit: CH-RB12MOLVWM-230VI (Olivia Midnight Black)\u003c\/li\u003e\n\u003cli\u003eOutdoor unit: CH-RES12-230VO (Regular)\u003c\/li\u003e\n\u003cli\u003eRemote control (included)\u003c\/li\u003e\n\u003cli\u003eSmart Kit for app control\u003c\/li\u003e\n\u003cli\u003eManufacturer documentation (see Documents \u0026amp; Downloads)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"hvx-desc-card\"\u003e\n\u003ch2 class=\"hvx-section-title\"\u003eIndoor Specs\u003c\/h2\u003e\n\u003cdiv class=\"hvx-table-wrap\"\u003e\n\u003ctable class=\"hvx-table\" aria-label=\"Indoor unit specifications\"\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eSpec\u003c\/th\u003e\n\u003cth\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCH-RB12MOLVWM-230VI\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRefrigerant type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eR454B\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSystem type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSingle\/Multi-zone unit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower source\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e208–230V, 1Ph, 60Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBTU rated\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e12,000\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSEER2\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e23.1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEER2\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e13\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDehumidification\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2.83 pnt\/day\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eVoltage range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e187–253 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eController\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eRG10K-exclusive remote\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRefrigerant piping (liq\/gas)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1\/4\" \/ 3\/8\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMinimum circuit ampacity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMax fuse\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e15\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIndoor noise level (H\/M\/L)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e42 \/ 36 \/ 25\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIndoor air flow\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e341.18 \/ 291.18 \/ 194.12 \/ 152.94\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eUnit dimensions (W×H×D)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e31.57 × 7.87 × 11.61\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePacking dimensions (W×D×H)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e34.45 × 11.22 × 14.96\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNet \/ Gross weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e18.74 \/ 24.25\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating range (Cooling)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e60–90\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating range (Heating)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e32–86\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDrainage water pipe diameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e5\/8\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"hvx-desc-card\"\u003e\n\u003ch2 class=\"hvx-section-title\"\u003eOutdoor Specs\u003c\/h2\u003e\n\u003cdiv class=\"hvx-table-wrap\"\u003e\n\u003ctable class=\"hvx-table\" aria-label=\"Outdoor unit specifications\"\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eSpec\u003c\/th\u003e\n\u003cth\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCH-RES12-230VO\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSystem type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSingle-zone unit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRefrigerant type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eR454B\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBTU rated\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e12,000\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower source\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e208–230V, 1Ph, 60Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eVoltage range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e187–253 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRefrigerant piping (liq\/gas)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1\/4\" \/ 3\/8\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMax pipe length\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e82 ft\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMax height difference (IDU↔ODU)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e49.2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCooling capacity (Min\/Max)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e11,500 (3,100~13,000)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eHeating capacity (Min\/Max)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e12,000 (3,700~15,600)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSEER2\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e19\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEER2\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e11.7\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eHSPF2-5\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eHSPF2-4\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e10.2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCOP\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3.42\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDehumidification\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2.09 pnt\/day\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOutdoor noise level\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e55.5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOutdoor air flow\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1,236.1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMinimum circuit ampacity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e12\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMax fuse\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e15\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAmbient temp (Heating)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e−13~75\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAmbient temp (Cooling)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e−13~122\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eUnit dimensions (W×H×D)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e30.12 × 11.93 × 21.85\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNet \/ Gross weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e62.17 \/ 67.68\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePacking dimensions (W×D×H)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e34.92 × 13.27 × 24.02\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRefrigerant precharge\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e25\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAdditional charge (1\/4\" liquid)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.16\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"hvx-desc-card\"\u003e\n\u003ch2 class=\"hvx-section-title\"\u003eDocuments \u0026amp; Downloads\u003c\/h2\u003e\n\u003cul style=\"padding-left: 18px; margin: 8px 0;\"\u003e\n\u003cli\u003e\u003ca class=\"hvx-link\" href=\"https:\/\/media.cooperandhunter.us\/4954\/CH-RES12-230VO-_-CH-RB12MOLVWM-230VI.pdf\" rel=\"noopener\" target=\"_blank\"\u003eSubmittal (PDF) — CH-RES12-230VO + CH-RB12MOLVWM-230VI\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca class=\"hvx-link\" href=\"https:\/\/media.cooperandhunter.us\/4959\/CH-RHP12-230VO_CH-RB12MOLVWM-230VI.pdf\" rel=\"noopener\" target=\"_blank\"\u003eSubmittal (PDF) — CH-RHP12-230VO + CH-RB12MOLVWM-230VI\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca class=\"hvx-link\" href=\"https:\/\/media.cooperandhunter.us\/4963\/CH-RB12MOLVWM-230VI.pdf\" rel=\"noopener\" target=\"_blank\"\u003eSubmittal (PDF) — CH-RB12MOLVWM-230VI\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca class=\"hvx-link\" href=\"https:\/\/media.cooperandhunter.us\/4156\/CH-RES12-230VO-%2B-CH-PRO12MASTWM-230VI.pdf\" rel=\"noopener\" target=\"_blank\"\u003eSubmittal (PDF) — CH-RES12-230VO + CH-PRO12MASTWM-230VI\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca class=\"hvx-link\" href=\"https:\/\/media.cooperandhunter.us\/4169\/CH-RES12-230VO-%2B-CH-RH12MASTWM-230VI.pdf\" rel=\"noopener\" target=\"_blank\"\u003eSubmittal (PDF) — CH-RES12-230VO + CH-RH12MASTWM-230VI\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca class=\"hvx-link\" href=\"https:\/\/media.cooperandhunter.us\/4210\/CH-RES12-230VO-%2B-CH-RS06-12MDT--MS.pdf\" rel=\"noopener\" target=\"_blank\"\u003eSubmittal (PDF) — CH-RES12-230VO + CH-RS06-12MDT-MS\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca class=\"hvx-link\" href=\"https:\/\/media.cooperandhunter.us\/4677\/CH-RES12-230VO_CH-RSH12MCT.pdf\" rel=\"noopener\" target=\"_blank\"\u003eSubmittal (PDF) — CH-RES12-230VO + CH-RSH12MCT\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca class=\"hvx-link\" href=\"https:\/\/media.cooperandhunter.us\/4676\/CH-RES12-230VO_CH-RH12MCT.pdf\" rel=\"noopener\" target=\"_blank\"\u003eSubmittal (PDF) — CH-RES12-230VO + CH-RH12MCT\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca class=\"hvx-link\" href=\"https:\/\/media.cooperandhunter.us\/4118\/Installation-Manual-R454B-Outdoor-units--.pdf\" rel=\"noopener\" target=\"_blank\"\u003eInstallation Manual (PDF) — R454B Outdoor Units\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca class=\"hvx-link\" href=\"https:\/\/media.cooperandhunter.us\/4200\/SlimDuct-Leaflet-R454B.pdf\" rel=\"noopener\" target=\"_blank\"\u003eSlimDuct Leaflet (PDF) — R454B\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca class=\"hvx-link\" href=\"https:\/\/www.ahridirectory.org\/NewSearch?programId=41\u0026amp;searchTypeId=3\u0026amp;productTypeId=4\" rel=\"noopener\" target=\"_blank\"\u003eAHRI Directory\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca class=\"hvx-link\" href=\"https:\/\/cooperandhunter.us\/product\/ch-res12-230vo\" rel=\"noopener\" target=\"_blank\"\u003eManufacturer Page — CH-RES12-230VO\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"hvx-desc-card\"\u003e\n\u003ch2 class=\"hvx-section-title\"\u003eImportant\u003c\/h2\u003e\n\u003cp style=\"margin: 0; font-size: 14px; color: var(--hvx-slate);\"\u003eProfessional installation is recommended. Verify electrical requirements, line sizes, maximum line length, and ambient operating limits before installation.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"hvx-desc-card\"\u003e\n\u003ch2 class=\"hvx-section-title\"\u003eFAQs\u003c\/h2\u003e\n\u003cdetails class=\"hvx-faq\" open=\"\"\u003e\n\u003csummary\u003eWhat voltage does this system require?\u003c\/summary\u003e\n\u003cdiv style=\"margin-top: 8px;\"\u003e208–230V, single phase, 60Hz.\u003c\/div\u003e\n\u003c\/details\u003e\n\u003cdetails class=\"hvx-faq\" open=\"\"\u003e\n\u003csummary\u003eWhat line sizes does this system use?\u003c\/summary\u003e\n\u003cdiv style=\"margin-top: 8px;\"\u003e1\/4\" liquid and 3\/8\" gas.\u003c\/div\u003e\n\u003c\/details\u003e\n\u003cdetails class=\"hvx-faq\" open=\"\"\u003e\n\u003csummary\u003eWhat is the max line length and height difference?\u003c\/summary\u003e\n\u003cdiv style=\"margin-top: 8px;\"\u003eMaximum line length is 82 ft and maximum height difference is 49.2 ft.\u003c\/div\u003e\n\u003c\/details\u003e\n\u003cdetails class=\"hvx-faq\" open=\"\"\u003e\n\u003csummary\u003eWhat are the outdoor ambient operating ranges?\u003c\/summary\u003e\n\u003cdiv style=\"margin-top: 8px;\"\u003eCooling: −13~122. Heating: −13~75.\u003c\/div\u003e\n\u003c\/details\u003e\n\u003cdetails class=\"hvx-faq\" open=\"\"\u003e\n\u003csummary\u003eWhat control options are supported?\u003c\/summary\u003e\n\u003cdiv style=\"margin-top: 8px;\"\u003eSmart Kit app control and remote are supported; a wall thermostat can be purchased separately.\u003c\/div\u003e\n\u003c\/details\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e","brand":"Cooper\u0026Hunter","offers":[{"title":"No installation","offer_id":42690262171691,"sku":"CH-RB12MOLVWM-230VI + CH-RES12-230VO","price":1160.0,"currency_code":"USD","in_stock":true},{"title":"16FT","offer_id":42690262204459,"sku":"CH-RB12MOLVWM-230VI + CH-RES12-230VO","price":1341.0,"currency_code":"USD","in_stock":true},{"title":"25FT","offer_id":42690262237227,"sku":"CH-RB12MOLVWM-230VI + CH-RES12-230VO","price":1387.0,"currency_code":"USD","in_stock":true},{"title":"50FT","offer_id":42690262269995,"sku":"CH-RB12MOLVWM-230VI + CH-RES12-230VO","price":1607.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0625\/5647\/1339\/files\/Midnight_Bundle_1_1_e4edcfca-3bd5-4b28-88ee-89dc2ad3d459.jpg?v=1769199500"},{"product_id":"cooper-hunter-18-000-btu-olivia-midnight-single-zone-wall-mount-minisplit-heat-pump-system-r454b-230v","title":"Cooper\u0026Hunter 18,000 BTU Olivia Midnight Single Zone Wall Mount Minisplit Heat Pump System R454B 230V","description":"\u003cstyle\u003e\n  :root{\n    --hvx-golden:#FAA819;\n    --hvx-slate:#262626;\n    --hvx-ivory:#F4F1E6;\n    --hvx-border:#e2e0d5;\n    --hvx-card-bg:#ffffff;\n  }\n\n  .hvx-desc{\n    font-family:\"Articulat CF\",system-ui,-apple-system,BlinkMacSystemFont,\"Segoe UI\",sans-serif;\n    color:var(--hvx-slate);\n    line-height:1.6;\n    background:var(--hvx-ivory);\n    padding:18px 18px 20px;\n    border-radius:16px;\n  }\n\n  .hvx-desc-header{\n    border-radius:14px;\n    padding:14px 16px;\n    background:linear-gradient(120deg,var(--hvx-golden),var(--hvx-slate));\n    color:#fff;\n    margin:0 0 16px;\n    box-shadow:0 10px 24px rgba(0,0,0,.22);\n    display:flex;\n    align-items:flex-start;\n    gap:12px;\n    flex-wrap:wrap;\n  }\n\n  .hvx-header-text{display:flex;flex-direction:column;gap:6px;min-width:260px}\n  .hvx-eyebrow{\n    font-size:11px;\n    letter-spacing:.14em;\n    text-transform:uppercase;\n    opacity:.9;\n  }\n  .hvx-title{\n    margin:0;\n    font-family:\"Anton\",\"Impact\",system-ui,-apple-system,BlinkMacSystemFont,\"Segoe UI\",sans-serif;\n    font-size:22px;\n    line-height:1.15;\n  }\n  .hvx-subtitle{margin:0;font-size:14px;opacity:.95}\n\n  .hvx-desc-card{\n    border:1px solid var(--hvx-border);\n    border-radius:14px;\n    background:var(--hvx-card-bg);\n    padding:16px 18px 18px;\n    box-shadow:0 4px 12px rgba(0,0,0,.06);\n    margin:14px 0;\n  }\n\n  .hvx-section-title{\n    margin:0 0 10px;\n    font-family:\"Anton\",\"Impact\",system-ui,-apple-system,BlinkMacSystemFont,\"Segoe UI\",sans-serif;\n    font-size:17px;\n    letter-spacing:.08em;\n    text-transform:uppercase;\n    color:var(--hvx-slate);\n    display:inline-flex;\n    align-items:center;\n    gap:8px;\n  }\n  .hvx-section-title::after{\n    content:\"\";\n    flex:1;\n    height:2px;\n    border-radius:999px;\n    background:linear-gradient(90deg,var(--hvx-golden),transparent);\n    opacity:.9;\n  }\n\n  .hvx-cta{display:flex;flex-wrap:wrap;gap:10px;margin:10px 0 0}\n  .hvx-cta a{\n    display:inline-flex;\n    align-items:center;\n    gap:8px;\n    padding:10px 14px;\n    border-radius:12px;\n    border:1px solid var(--hvx-border);\n    background:#fff;\n    text-decoration:none;\n    color:var(--hvx-slate);\n    font-size:14px;\n    font-weight:700;\n  }\n  .hvx-cta a.primary{\n    background:var(--hvx-slate);\n    color:#fff;\n    border-color:transparent;\n  }\n\n  .hvx-badges{display:flex;flex-wrap:wrap;gap:8px;margin:10px 0 0}\n  .hvx-badge{\n    font-size:12px;\n    border:1px solid var(--hvx-border);\n    border-radius:999px;\n    padding:6px 10px;\n    background:#fff;\n    white-space:nowrap;\n  }\n\n  .hvx-kv{\n    display:grid;\n    grid-template-columns:repeat(4,minmax(160px,1fr));\n    gap:10px;\n    margin-top:10px;\n  }\n  .hvx-kv \u003e div{\n    border:1px solid var(--hvx-border);\n    background:#fff;\n    border-radius:12px;\n    padding:10px 12px;\n    text-align:center;\n  }\n  .hvx-kv strong{display:block}\n\n  .hvx-table{\n    width:100%;\n    border-collapse:collapse;\n    min-width:520px;\n    background:#fff;\n    border:1px solid var(--hvx-border);\n    border-radius:12px;\n    overflow:hidden;\n  }\n  .hvx-table th,.hvx-table td{\n    border-bottom:1px solid var(--hvx-border);\n    padding:10px 12px;\n    vertical-align:top;\n    font-size:14px;\n  }\n  .hvx-table th{ text-align:left; font-weight:800; background:#fff; }\n  .hvx-table tr:nth-child(even) td{ background:#fbfaf6; }\n  .hvx-table tr:last-child td{ border-bottom:none; }\n  .hvx-table-wrap{ overflow:auto; border-radius:12px; }\n\n  .hvx-link{color:var(--hvx-slate); text-decoration:underline; text-underline-offset:2px}\n  .hvx-link:hover{opacity:.85}\n\n  details.hvx-faq{\n    border:1px solid var(--hvx-border);\n    background:#fff;\n    border-radius:12px;\n    padding:10px 12px;\n    margin:8px 0;\n  }\n  details.hvx-faq summary{cursor:pointer;font-weight:800}\n\n  @media(max-width:980px){\n    .hvx-kv{grid-template-columns:repeat(2,minmax(160px,1fr))}\n  }\n  @media(max-width:768px){\n    .hvx-desc{padding:14px 12px 16px;border-radius:12px}\n    .hvx-desc-header{padding:12px;border-radius:12px}\n    .hvx-title{font-size:19px}\n    .hvx-desc-card{padding:14px;margin:10px 0}\n  }\n\u003c\/style\u003e\n\u003cdiv class=\"hvx-desc\"\u003e\n\u003cdiv class=\"hvx-desc-header\"\u003e\n\u003cdiv class=\"hvx-header-text\"\u003e\n\u003cdiv class=\"hvx-eyebrow\"\u003eCooper\u0026amp;Hunter Olivia Midnight • Black • R454B • 230V\u003c\/div\u003e\n\u003ch1 class=\"hvx-title\"\u003eCooper\u0026amp;Hunter 18,000 BTU Olivia Midnight Single Zone Wall Mount Mini Split Heat Pump System R454B 230V\u003c\/h1\u003e\n\u003cp class=\"hvx-subtitle\"\u003e\u003cstrong\u003eSKU:\u003c\/strong\u003e CH-RB18MOLVWM-230VI + CH-RES18-230VO\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"hvx-cta\" aria-label=\"Contact options\"\u003e\n\u003ca class=\"primary\" href=\"https:\/\/hvacsupplies.com\/pages\/contact\" rel=\"noopener\" title=\"Contact Us\" target=\"_blank\"\u003e CLICK HERE TO CONTACT US FOR CUSTOM QUOTES AND QUESTIONS \u003c\/a\u003e \u003ca href=\"tel:+18005438933\" title=\"Call Us Now!\"\u003e CLICK TO CALL US 800-543-8933 FOR ANY QUESTIONS \u003c\/a\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"hvx-desc-card\"\u003e\n\u003ch2 class=\"hvx-section-title\"\u003eOverview\u003c\/h2\u003e\n\u003cp style=\"margin: 0;\"\u003eTransform your home’s climate control with the Cooper\u0026amp;Hunter \u003cstrong\u003e18K BTU Olivia Midnight\u003c\/strong\u003e wall-mounted mini split system, featuring the new \u003cstrong\u003eR454B refrigerant\u003c\/strong\u003e and an elegant \u003cstrong\u003eblack\u003c\/strong\u003e indoor unit for a modern, premium look. Designed for \u003cstrong\u003e208–230V\u003c\/strong\u003e installations, Olivia Midnight combines advanced comfort features with efficient performance (up to \u003cstrong\u003e24 SEER2\u003c\/strong\u003e).\u003c\/p\u003e\n\u003cp style=\"margin: 10px 0 0;\"\u003eComfort and convenience features include \u003cstrong\u003eAuto-Swing\u003c\/strong\u003e horizontal louvers for improved air circulation, \u003cstrong\u003eTurbo Mode\u003c\/strong\u003e for rapid heating\/cooling, \u003cstrong\u003eFollow Me\u003c\/strong\u003e sensing from the remote, \u003cstrong\u003eTimer On\/Off\u003c\/strong\u003e and \u003cstrong\u003eSleep Mode\u003c\/strong\u003e, plus \u003cstrong\u003e46° Freeze Protection\u003c\/strong\u003e. Advanced technology includes \u003cstrong\u003e12Hz\u003c\/strong\u003e ultra-low compressor speed for quiet efficiency, \u003cstrong\u003eHigh-Frequency Racer Technology\u003c\/strong\u003e for fast startup response, an \u003cstrong\u003eelectronic expansion valve\u003c\/strong\u003e for optimized refrigerant flow management, and an \u003cstrong\u003eintelligent dusting switch\u003c\/strong\u003e that reverses the fan to help clear dust, sand, and debris from the coil. Built with \u003cstrong\u003eTU1 copper tubes\u003c\/strong\u003e for durability and efficient heat transfer.\u003c\/p\u003e\n\u003cp style=\"margin: 10px 0 0;\"\u003eThe Regular single-zone outdoor unit uses inverter control to closely match heating\/cooling demand while helping reduce energy use.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"hvx-desc-card\"\u003e\n\u003ch2 class=\"hvx-section-title\"\u003eHighlights\u003c\/h2\u003e\n\u003cdiv class=\"hvx-badges\" role=\"list\"\u003e\n\u003cspan class=\"hvx-badge\" role=\"listitem\"\u003e18,000 BTU class\u003c\/span\u003e \u003cspan class=\"hvx-badge\" role=\"listitem\"\u003eOlivia Midnight (Black indoor)\u003c\/span\u003e \u003cspan class=\"hvx-badge\" role=\"listitem\"\u003eR454B refrigerant\u003c\/span\u003e \u003cspan class=\"hvx-badge\" role=\"listitem\"\u003eSEER2 24 (Indoor)\u003c\/span\u003e \u003cspan class=\"hvx-badge\" role=\"listitem\"\u003eEER2 13.5 (Indoor)\u003c\/span\u003e \u003cspan class=\"hvx-badge\" role=\"listitem\"\u003eInverter-driven performance\u003c\/span\u003e \u003cspan class=\"hvx-badge\" role=\"listitem\"\u003eSmart Kit included\u003c\/span\u003e \u003cspan class=\"hvx-badge\" role=\"listitem\"\u003eAuto-swing (horizontal louvers)\u003c\/span\u003e \u003cspan class=\"hvx-badge\" role=\"listitem\"\u003e208–230V, 1Ph, 60Hz\u003c\/span\u003e \u003cspan class=\"hvx-badge\" role=\"listitem\"\u003eSingle \/ Multi-zone capable indoor\u003c\/span\u003e\n\u003c\/div\u003e\n\u003cul style=\"margin: 12px 0 0; padding-left: 18px;\"\u003e\n\u003cli\u003e\n\u003cstrong\u003eEven air distribution:\u003c\/strong\u003e Auto-Swing louvers help reduce hot\/cold spots.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFast comfort:\u003c\/strong\u003e Turbo Mode and rapid startup response for quick temperature changes.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePersonalized control:\u003c\/strong\u003e Follow Me adjusts temperature based on remote sensor location.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSmart control ready:\u003c\/strong\u003e Smart Kit enables app connectivity and remote control.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eControl options:\u003c\/strong\u003e Remote included; wall thermostat optional (sold separately).\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cdiv class=\"hvx-kv\" role=\"list\" aria-label=\"At-a-glance\"\u003e\n\u003cdiv role=\"listitem\"\u003e\n\u003cstrong\u003eIndoor\u003c\/strong\u003eCH-RB18MOLVWM-230VI\u003c\/div\u003e\n\u003cdiv role=\"listitem\"\u003e\n\u003cstrong\u003eOutdoor\u003c\/strong\u003eCH-RES18-230VO\u003c\/div\u003e\n\u003cdiv role=\"listitem\"\u003e\n\u003cstrong\u003eLines\u003c\/strong\u003e1\/4\" liquid · 1\/2\" gas\u003c\/div\u003e\n\u003cdiv role=\"listitem\"\u003e\n\u003cstrong\u003eMax run\u003c\/strong\u003e98.4 ft\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"hvx-desc-card\"\u003e\n\u003ch2 class=\"hvx-section-title\"\u003eWhat’s Included\u003c\/h2\u003e\n\u003cul style=\"padding-left: 18px; margin: 8px 0;\"\u003e\n\u003cli\u003eIndoor unit: CH-RB18MOLVWM-230VI (Olivia Midnight Black)\u003c\/li\u003e\n\u003cli\u003eOutdoor unit: CH-RES18-230VO (Regular)\u003c\/li\u003e\n\u003cli\u003eRemote control (included)\u003c\/li\u003e\n\u003cli\u003eSmart Kit for app control\u003c\/li\u003e\n\u003cli\u003eManufacturer documentation (see Documents \u0026amp; Downloads)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"hvx-desc-card\"\u003e\n\u003ch2 class=\"hvx-section-title\"\u003eIndoor Specs\u003c\/h2\u003e\n\u003cdiv class=\"hvx-table-wrap\"\u003e\n\u003ctable class=\"hvx-table\" aria-label=\"Indoor unit specifications\"\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eSpec\u003c\/th\u003e\n\u003cth\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCH-RB18MOLVWM-230VI\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRefrigerant type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eR454B\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSystem type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSingle\/Multi-zone unit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower source\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e208–230V, 1Ph, 60Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBTU rated\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e18,000\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSEER2\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e24\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEER2\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e13.5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDehumidification\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3.28 pnt\/day\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eVoltage range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e187–253 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eController\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eRG10K-exclusive remote\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRefrigerant piping (liq\/gas)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1\/4\" \/ 1\/2\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMinimum circuit ampacity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMax fuse\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e15\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIndoor noise level (H\/M\/L)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e45.5 \/ 41 \/ 24.5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIndoor air flow\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e760.59 \/ 530.59 \/ 458.82 \/ 382.35\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eUnit dimensions (W×H×D)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e42.64 × 9.61 × 13.23\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePacking dimensions (W×D×H)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e45.47 × 16.34 × 12.40\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNet \/ Gross weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e29.54 \/ 37.48\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating range (Cooling)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e60–90\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating range (Heating)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e32–86\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDrainage water pipe diameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e5\/8\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"hvx-desc-card\"\u003e\n\u003ch2 class=\"hvx-section-title\"\u003eOutdoor Specs\u003c\/h2\u003e\n\u003cdiv class=\"hvx-table-wrap\"\u003e\n\u003ctable class=\"hvx-table\" aria-label=\"Outdoor unit specifications\"\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eSpec\u003c\/th\u003e\n\u003cth\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCH-RES18-230VO\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSystem type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSingle-zone unit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRefrigerant type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eR454B\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBTU rated\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e18,000\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower source\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e208–230V, 1Ph, 60Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eVoltage range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e187–253 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRefrigerant piping (liq\/gas)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1\/4\" \/ 1\/2\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMax pipe length\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e98.4 ft\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMax height difference (IDU↔ODU)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e65.6\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCooling capacity (Min\/Max)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e17,000 (7,000~19,000)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eHeating capacity (Min\/Max)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e20,000 (5,500~22,000)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSEER2\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEER2\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e12.5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eHSPF2-5\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e8.2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eHSPF2-4\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e10.5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCOP\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3.47\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDehumidification\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3.09 pnt\/day\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOutdoor noise level\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e59\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOutdoor air flow\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1,765.8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMinimum circuit ampacity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e18\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMax fuse\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAmbient temp (Heating)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e−13~75\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAmbient temp (Cooling)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e−13~122\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eUnit dimensions (W×H×D)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e35.04 × 13.46 × 26.5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNet \/ Gross weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e92.59 \/ 100.31\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePacking dimensions (W×D×H)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e39.17 × 15.67 × 29.13\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRefrigerant precharge\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e25\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAdditional charge (1\/4\" liquid)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.16\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"hvx-desc-card\"\u003e\n\u003ch2 class=\"hvx-section-title\"\u003eDocuments \u0026amp; Downloads\u003c\/h2\u003e\n\u003cul style=\"padding-left: 18px; margin: 8px 0;\"\u003e\n\u003cli\u003e\u003ca class=\"hvx-link\" href=\"https:\/\/media.cooperandhunter.us\/4955\/CH-RES18-230VO-_-CH-RB18MOLVWM-230VI.pdf\" rel=\"noopener\" target=\"_blank\"\u003eSubmittal (PDF) — CH-RES18-230VO + CH-RB18MOLVWM-230VI\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca class=\"hvx-link\" href=\"https:\/\/media.cooperandhunter.us\/4960\/CH-RHP18-230VO_CH-RB18MOLVWM-230VI.pdf\" rel=\"noopener\" target=\"_blank\"\u003eSubmittal (PDF) — CH-RHP18-230VO + CH-RB18MOLVWM-230VI\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca class=\"hvx-link\" href=\"https:\/\/media.cooperandhunter.us\/4964\/CH-RB18MOLVWM-230VI.pdf\" rel=\"noopener\" target=\"_blank\"\u003eSubmittal (PDF) — CH-RB18MOLVWM-230VI\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca class=\"hvx-link\" href=\"https:\/\/media.cooperandhunter.us\/4157\/CH-RES18-230VO-%2B-CH-PRO18MASTWM-230VI.pdf\" rel=\"noopener\" target=\"_blank\"\u003eSubmittal (PDF) — CH-RES18-230VO + CH-PRO18MASTWM-230VI\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca class=\"hvx-link\" href=\"https:\/\/media.cooperandhunter.us\/4171\/CH-RES18-230VO-%2B-CH-RH18MASTWM-230VI.pdf\" rel=\"noopener\" target=\"_blank\"\u003eSubmittal (PDF) — CH-RES18-230VO + CH-RH18MASTWM-230VI\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca class=\"hvx-link\" href=\"https:\/\/media.cooperandhunter.us\/4211\/CH-RES18-230VO-%2B-CH-RS18MDT-MS.pdf\" rel=\"noopener\" target=\"_blank\"\u003eSubmittal (PDF) — CH-RES18-230VO + CH-RS18MDT-MS\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca class=\"hvx-link\" href=\"https:\/\/media.cooperandhunter.us\/4625\/CH-RES18-230VO_CH-RSH18MFC.pdf\" rel=\"noopener\" target=\"_blank\"\u003eSubmittal (PDF) — CH-RES18-230VO + CH-RSH18MFC\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca class=\"hvx-link\" href=\"https:\/\/media.cooperandhunter.us\/4679\/CH-RES18-230VO_CH-RSH18MCT.pdf\" rel=\"noopener\" target=\"_blank\"\u003eSubmittal (PDF) — CH-RES18-230VO + CH-RSH18MCT\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca class=\"hvx-link\" href=\"https:\/\/media.cooperandhunter.us\/4678\/CH-RES18-230VO_CH-RH18MCT.pdf\" rel=\"noopener\" target=\"_blank\"\u003eSubmittal (PDF) — CH-RES18-230VO + CH-RH18MCT\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca class=\"hvx-link\" href=\"https:\/\/media.cooperandhunter.us\/4118\/Installation-Manual-R454B-Outdoor-units--.pdf\" rel=\"noopener\" target=\"_blank\"\u003eInstallation Manual (PDF) — R454B Outdoor Units\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca class=\"hvx-link\" href=\"https:\/\/media.cooperandhunter.us\/4200\/SlimDuct-Leaflet-R454B.pdf\" rel=\"noopener\" target=\"_blank\"\u003eSlimDuct Leaflet (PDF) — R454B\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca class=\"hvx-link\" href=\"https:\/\/www.ahridirectory.org\/NewSearch?programId=41\u0026amp;searchTypeId=3\u0026amp;productTypeId=4\" rel=\"noopener\" target=\"_blank\"\u003eAHRI Directory\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca class=\"hvx-link\" href=\"https:\/\/cooperandhunter.us\/product\/ch-rb18molvwm-230vi\" rel=\"noopener\" target=\"_blank\"\u003eManufacturer Page — CH-RB18MOLVWM-230VI\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca class=\"hvx-link\" href=\"https:\/\/cooperandhunter.us\/product\/ch-res18-230vo\" rel=\"noopener\" target=\"_blank\"\u003eManufacturer Page — CH-RES18-230VO\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"hvx-desc-card\"\u003e\n\u003ch2 class=\"hvx-section-title\"\u003eImportant\u003c\/h2\u003e\n\u003cp style=\"margin: 0; font-size: 14px; color: var(--hvx-slate);\"\u003eProfessional installation is recommended. Verify electrical requirements, line sizes, maximum line length, and ambient operating limits before installation.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"hvx-desc-card\"\u003e\n\u003ch2 class=\"hvx-section-title\"\u003eFAQs\u003c\/h2\u003e\n\u003cdetails class=\"hvx-faq\" open=\"\"\u003e\n\u003csummary\u003eWhat voltage does this system require?\u003c\/summary\u003e\n\u003cdiv style=\"margin-top: 8px;\"\u003e208–230V, single phase, 60Hz.\u003c\/div\u003e\n\u003c\/details\u003e\n\u003cdetails class=\"hvx-faq\" open=\"\"\u003e\n\u003csummary\u003eWhat line sizes does this system use?\u003c\/summary\u003e\n\u003cdiv style=\"margin-top: 8px;\"\u003e1\/4\" liquid and 1\/2\" gas.\u003c\/div\u003e\n\u003c\/details\u003e\n\u003cdetails class=\"hvx-faq\" open=\"\"\u003e\n\u003csummary\u003eWhat is the max line length and height difference?\u003c\/summary\u003e\n\u003cdiv style=\"margin-top: 8px;\"\u003eMaximum line length is 98.4 ft and maximum height difference is 65.6.\u003c\/div\u003e\n\u003c\/details\u003e\n\u003cdetails class=\"hvx-faq\" open=\"\"\u003e\n\u003csummary\u003eWhat are the outdoor ambient operating ranges?\u003c\/summary\u003e\n\u003cdiv style=\"margin-top: 8px;\"\u003eCooling: −13~122. Heating: −13~75.\u003c\/div\u003e\n\u003c\/details\u003e\n\u003cdetails class=\"hvx-faq\" open=\"\"\u003e\n\u003csummary\u003eWhat refrigerant does this system use?\u003c\/summary\u003e\n\u003cdiv style=\"margin-top: 8px;\"\u003eR454B.\u003c\/div\u003e\n\u003c\/details\u003e\n\u003cdetails class=\"hvx-faq\" open=\"\"\u003e\n\u003csummary\u003eWhat control options are supported?\u003c\/summary\u003e\n\u003cdiv style=\"margin-top: 8px;\"\u003eSmart Kit app control and remote are supported; a wall thermostat can be purchased separately.\u003c\/div\u003e\n\u003c\/details\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e","brand":"Cooper\u0026Hunter","offers":[{"title":"No installation","offer_id":42690319613995,"sku":"CH-RB18MOLVWM-230VI + CH-RES18-230VO","price":1645.0,"currency_code":"USD","in_stock":true},{"title":"16FT","offer_id":42690319646763,"sku":"CH-RB18MOLVWM-230VI + CH-RES18-230VO","price":1853.0,"currency_code":"USD","in_stock":true},{"title":"25FT","offer_id":42690319679531,"sku":"CH-RB18MOLVWM-230VI + CH-RES18-230VO","price":1898.0,"currency_code":"USD","in_stock":true},{"title":"50FT","offer_id":42690319712299,"sku":"CH-RB18MOLVWM-230VI + CH-RES18-230VO","price":2101.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0625\/5647\/1339\/files\/Midnight_Bundle_1_1.jpg?v=1768238917"},{"product_id":"cooper-hunter-24-000-btu-olivia-midnight-single-zone-wall-mount-minisplit-heat-pump-system-r454b-230v","title":"Cooper\u0026Hunter 24,000 BTU Olivia Midnight Single Zone Wall Mount Minisplit Heat Pump System R454B 230V","description":"\u003cstyle\u003e\n  :root{\n    --hvx-golden:#FAA819;\n    --hvx-slate:#262626;\n    --hvx-ivory:#F4F1E6;\n    --hvx-border:#e2e0d5;\n    --hvx-card-bg:#ffffff;\n  }\n\n  .hvx-desc{\n    font-family:\"Articulat CF\",system-ui,-apple-system,BlinkMacSystemFont,\"Segoe UI\",sans-serif;\n    color:var(--hvx-slate);\n    line-height:1.6;\n    background:var(--hvx-ivory);\n    padding:18px 18px 20px;\n    border-radius:16px;\n  }\n\n  .hvx-desc-header{\n    border-radius:14px;\n    padding:14px 16px;\n    background:linear-gradient(120deg,var(--hvx-golden),var(--hvx-slate));\n    color:#fff;\n    margin:0 0 16px;\n    box-shadow:0 10px 24px rgba(0,0,0,.22);\n    display:flex;\n    align-items:flex-start;\n    gap:12px;\n    flex-wrap:wrap;\n  }\n\n  .hvx-header-text{display:flex;flex-direction:column;gap:6px;min-width:260px}\n  .hvx-eyebrow{\n    font-size:11px;\n    letter-spacing:.14em;\n    text-transform:uppercase;\n    opacity:.9;\n  }\n  .hvx-title{\n    margin:0;\n    font-family:\"Anton\",\"Impact\",system-ui,-apple-system,BlinkMacSystemFont,\"Segoe UI\",sans-serif;\n    font-size:22px;\n    line-height:1.15;\n  }\n  .hvx-subtitle{margin:0;font-size:14px;opacity:.95}\n\n  .hvx-desc-card{\n    border:1px solid var(--hvx-border);\n    border-radius:14px;\n    background:var(--hvx-card-bg);\n    padding:16px 18px 18px;\n    box-shadow:0 4px 12px rgba(0,0,0,.06);\n    margin:14px 0;\n  }\n\n  .hvx-section-title{\n    margin:0 0 10px;\n    font-family:\"Anton\",\"Impact\",system-ui,-apple-system,BlinkMacSystemFont,\"Segoe UI\",sans-serif;\n    font-size:17px;\n    letter-spacing:.08em;\n    text-transform:uppercase;\n    color:var(--hvx-slate);\n    display:inline-flex;\n    align-items:center;\n    gap:8px;\n  }\n  .hvx-section-title::after{\n    content:\"\";\n    flex:1;\n    height:2px;\n    border-radius:999px;\n    background:linear-gradient(90deg,var(--hvx-golden),transparent);\n    opacity:.9;\n  }\n\n  .hvx-cta{display:flex;flex-wrap:wrap;gap:10px;margin:10px 0 0}\n  .hvx-cta a{\n    display:inline-flex;\n    align-items:center;\n    gap:8px;\n    padding:10px 14px;\n    border-radius:12px;\n    border:1px solid var(--hvx-border);\n    background:#fff;\n    text-decoration:none;\n    color:var(--hvx-slate);\n    font-size:14px;\n    font-weight:700;\n  }\n  .hvx-cta a.primary{\n    background:var(--hvx-slate);\n    color:#fff;\n    border-color:transparent;\n  }\n\n  .hvx-badges{display:flex;flex-wrap:wrap;gap:8px;margin:10px 0 0}\n  .hvx-badge{\n    font-size:12px;\n    border:1px solid var(--hvx-border);\n    border-radius:999px;\n    padding:6px 10px;\n    background:#fff;\n    white-space:nowrap;\n  }\n\n  .hvx-kv{\n    display:grid;\n    grid-template-columns:repeat(4,minmax(160px,1fr));\n    gap:10px;\n    margin-top:10px;\n  }\n  .hvx-kv \u003e div{\n    border:1px solid var(--hvx-border);\n    background:#fff;\n    border-radius:12px;\n    padding:10px 12px;\n    text-align:center;\n  }\n  .hvx-kv strong{display:block}\n\n  .hvx-table{\n    width:100%;\n    border-collapse:collapse;\n    min-width:520px;\n    background:#fff;\n    border:1px solid var(--hvx-border);\n    border-radius:12px;\n    overflow:hidden;\n  }\n  .hvx-table th,.hvx-table td{\n    border-bottom:1px solid var(--hvx-border);\n    padding:10px 12px;\n    vertical-align:top;\n    font-size:14px;\n  }\n  .hvx-table th{ text-align:left; font-weight:800; background:#fff; }\n  .hvx-table tr:nth-child(even) td{ background:#fbfaf6; }\n  .hvx-table tr:last-child td{ border-bottom:none; }\n  .hvx-table-wrap{ overflow:auto; border-radius:12px; }\n\n  .hvx-link{color:var(--hvx-slate); text-decoration:underline; text-underline-offset:2px}\n  .hvx-link:hover{opacity:.85}\n\n  details.hvx-faq{\n    border:1px solid var(--hvx-border);\n    background:#fff;\n    border-radius:12px;\n    padding:10px 12px;\n    margin:8px 0;\n  }\n  details.hvx-faq summary{cursor:pointer;font-weight:800}\n\n  @media(max-width:980px){\n    .hvx-kv{grid-template-columns:repeat(2,minmax(160px,1fr))}\n  }\n  @media(max-width:768px){\n    .hvx-desc{padding:14px 12px 16px;border-radius:12px}\n    .hvx-desc-header{padding:12px;border-radius:12px}\n    .hvx-title{font-size:19px}\n    .hvx-desc-card{padding:14px;margin:10px 0}\n  }\n\u003c\/style\u003e\n\u003cdiv class=\"hvx-desc\"\u003e\n\u003cdiv class=\"hvx-desc-header\"\u003e\n\u003cdiv class=\"hvx-header-text\"\u003e\n\u003cdiv class=\"hvx-eyebrow\"\u003eCooper\u0026amp;Hunter Olivia Midnight • Black • R454B • 230V\u003c\/div\u003e\n\u003ch1 class=\"hvx-title\"\u003eCooper\u0026amp;Hunter 24,000 BTU Olivia Midnight Single Zone Wall Mount Mini Split Heat Pump System R454B 230V\u003c\/h1\u003e\n\u003cp class=\"hvx-subtitle\"\u003e\u003cstrong\u003eSKU:\u003c\/strong\u003e CH-RB24MOLVWM-230VI + CH-RES24-230VO\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"hvx-cta\" aria-label=\"Contact options\"\u003e\n\u003ca class=\"primary\" href=\"https:\/\/hvacsupplies.com\/pages\/contact\" rel=\"noopener\" title=\"Contact Us\" target=\"_blank\"\u003e CLICK HERE TO CONTACT US FOR CUSTOM QUOTES AND QUESTIONS \u003c\/a\u003e \u003ca href=\"tel:+18005438933\" title=\"Call Us Now!\"\u003e CLICK TO CALL US 800-543-8933 FOR ANY QUESTIONS \u003c\/a\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"hvx-desc-card\"\u003e\n\u003ch2 class=\"hvx-section-title\"\u003eOverview\u003c\/h2\u003e\n\u003cp style=\"margin: 0;\"\u003eTransform your home’s climate control with the Cooper\u0026amp;Hunter \u003cstrong\u003e24K BTU Olivia Midnight\u003c\/strong\u003e wall-mounted mini split system, featuring the new \u003cstrong\u003eR454B refrigerant\u003c\/strong\u003e and an elegant \u003cstrong\u003eblack\u003c\/strong\u003e indoor unit for a modern, premium look. Designed for \u003cstrong\u003e208–230V\u003c\/strong\u003e installations, Olivia Midnight combines advanced comfort features with efficient performance (up to \u003cstrong\u003e23.5 SEER2\u003c\/strong\u003e).\u003c\/p\u003e\n\u003cp style=\"margin: 10px 0 0;\"\u003eComfort and convenience features include \u003cstrong\u003eAuto-Swing\u003c\/strong\u003e horizontal louvers for improved air circulation, \u003cstrong\u003eTurbo Mode\u003c\/strong\u003e for rapid heating\/cooling, \u003cstrong\u003eFollow Me\u003c\/strong\u003e sensing from the remote, \u003cstrong\u003eTimer On\/Off\u003c\/strong\u003e and \u003cstrong\u003eSleep Mode\u003c\/strong\u003e, plus \u003cstrong\u003e46° Freeze Protection\u003c\/strong\u003e. Advanced technology includes \u003cstrong\u003e12Hz\u003c\/strong\u003e ultra-low compressor speed for quiet efficiency, \u003cstrong\u003eHigh-Frequency Racer Technology\u003c\/strong\u003e for fast startup response, an \u003cstrong\u003eelectronic expansion valve\u003c\/strong\u003e for optimized refrigerant flow management, and an \u003cstrong\u003eintelligent dusting switch\u003c\/strong\u003e that reverses the fan to help clear dust, sand, and debris from the coil. Built with \u003cstrong\u003eTU1 copper tubes\u003c\/strong\u003e for durability and efficient heat transfer.\u003c\/p\u003e\n\u003cp style=\"margin: 10px 0 0;\"\u003eThe Regular single-zone outdoor unit uses inverter control to closely match heating\/cooling demand while helping reduce energy use.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"hvx-desc-card\"\u003e\n\u003ch2 class=\"hvx-section-title\"\u003eHighlights\u003c\/h2\u003e\n\u003cdiv class=\"hvx-badges\" role=\"list\"\u003e\n\u003cspan class=\"hvx-badge\" role=\"listitem\"\u003e24,000 BTU class\u003c\/span\u003e \u003cspan class=\"hvx-badge\" role=\"listitem\"\u003eOlivia Midnight (Black indoor)\u003c\/span\u003e \u003cspan class=\"hvx-badge\" role=\"listitem\"\u003eR454B refrigerant\u003c\/span\u003e \u003cspan class=\"hvx-badge\" role=\"listitem\"\u003eSEER2 23.5 (Indoor)\u003c\/span\u003e \u003cspan class=\"hvx-badge\" role=\"listitem\"\u003eEER2 13.5 (Indoor)\u003c\/span\u003e \u003cspan class=\"hvx-badge\" role=\"listitem\"\u003eInverter-driven performance\u003c\/span\u003e \u003cspan class=\"hvx-badge\" role=\"listitem\"\u003eSmart Kit included\u003c\/span\u003e \u003cspan class=\"hvx-badge\" role=\"listitem\"\u003eAuto-swing (horizontal louvers)\u003c\/span\u003e \u003cspan class=\"hvx-badge\" role=\"listitem\"\u003e208–230V, 1Ph, 60Hz\u003c\/span\u003e \u003cspan class=\"hvx-badge\" role=\"listitem\"\u003eSingle \/ Multi-zone capable indoor\u003c\/span\u003e\n\u003c\/div\u003e\n\u003cul style=\"margin: 12px 0 0; padding-left: 18px;\"\u003e\n\u003cli\u003e\n\u003cstrong\u003eEven air distribution:\u003c\/strong\u003e Auto-Swing louvers help reduce hot\/cold spots.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFast comfort:\u003c\/strong\u003e Turbo Mode and rapid startup response for quick temperature changes.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePersonalized control:\u003c\/strong\u003e Follow Me adjusts temperature based on remote sensor location.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSmart control ready:\u003c\/strong\u003e Smart Kit enables app connectivity and remote control.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eControl options:\u003c\/strong\u003e Remote included; wall thermostat optional (sold separately).\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cdiv class=\"hvx-kv\" role=\"list\" aria-label=\"At-a-glance\"\u003e\n\u003cdiv role=\"listitem\"\u003e\n\u003cstrong\u003eIndoor\u003c\/strong\u003eCH-RB24MOLVWM-230VI\u003c\/div\u003e\n\u003cdiv role=\"listitem\"\u003e\n\u003cstrong\u003eOutdoor\u003c\/strong\u003eCH-RES24-230VO\u003c\/div\u003e\n\u003cdiv role=\"listitem\"\u003e\n\u003cstrong\u003eLines\u003c\/strong\u003e3\/8\" liquid · 5\/8\" gas\u003c\/div\u003e\n\u003cdiv role=\"listitem\"\u003e\n\u003cstrong\u003eMax run\u003c\/strong\u003e164 ft\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"hvx-desc-card\"\u003e\n\u003ch2 class=\"hvx-section-title\"\u003eWhat’s Included\u003c\/h2\u003e\n\u003cul style=\"padding-left: 18px; margin: 8px 0;\"\u003e\n\u003cli\u003eIndoor unit: CH-RB24MOLVWM-230VI (Olivia Midnight Black)\u003c\/li\u003e\n\u003cli\u003eOutdoor unit: CH-RES24-230VO (Regular)\u003c\/li\u003e\n\u003cli\u003eRemote control (included)\u003c\/li\u003e\n\u003cli\u003eSmart Kit for app control\u003c\/li\u003e\n\u003cli\u003eManufacturer documentation (see Documents \u0026amp; Downloads)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"hvx-desc-card\"\u003e\n\u003ch2 class=\"hvx-section-title\"\u003eIndoor Specs\u003c\/h2\u003e\n\u003cdiv class=\"hvx-table-wrap\"\u003e\n\u003ctable class=\"hvx-table\" aria-label=\"Indoor unit specifications\"\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eSpec\u003c\/th\u003e\n\u003cth\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCH-RB24MOLVWM-230VI\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRefrigerant type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eR454B\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSystem type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSingle\/Multi-zone unit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower source\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e208–230V, 1Ph, 60Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBTU rated\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e24,000\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSEER2\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e22.3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEER2\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e13.5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDehumidification\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e5.43 pnt\/day\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eVoltage range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e187–253 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eController\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eRG10K-exclusive remote\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRefrigerant piping (liq\/gas)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3\/8\" \/ 5\/8\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMinimum circuit ampacity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMax fuse\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e15\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIndoor noise level (H\/M\/L)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e48 \/ 40 \/ 28\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIndoor air flow\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e760.59 \/ 601.18 \/ 458.82 \/ 382.35\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eUnit dimensions (W×H×D)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e42.64 × 9.61 × 13.23\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePacking dimensions (W×D×H)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e45.47 × 16.34 × 12.40\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNet \/ Gross weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e29.98 \/ 38.14\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating range (Cooling)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e60–90\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating range (Heating)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e32–86\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDrainage water pipe diameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e5\/8\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"hvx-desc-card\"\u003e\n\u003ch2 class=\"hvx-section-title\"\u003eOutdoor Specs\u003c\/h2\u003e\n\u003cdiv class=\"hvx-table-wrap\"\u003e\n\u003ctable class=\"hvx-table\" aria-label=\"Outdoor unit specifications\"\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eSpec\u003c\/th\u003e\n\u003cth\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCH-RES24-230VO\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSystem type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSingle-zone unit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRefrigerant type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eR454B\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBTU rated\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e24,000\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower source\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e208–230V, 1Ph, 60Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eVoltage range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e187–253 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRefrigerant piping (liq\/gas)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3\/8\" \/ 5\/8\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMax pipe length\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e164 ft\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMax height difference (IDU↔ODU)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e82\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCooling capacity (Min\/Max)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e24,000 (8,500~28,300)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eHeating capacity (Min\/Max)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e25,000 (11,800~35,100)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSEER2\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e19\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEER2\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e12.5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eHSPF2-5\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e8.5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eHSPF2-4\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e11\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCOP\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3.64\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDehumidification\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4.52 pnt\/day\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOutdoor noise level\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e60\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOutdoor air flow\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2,236.7\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMinimum circuit ampacity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e24\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMax fuse\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e25\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAmbient temp (Heating)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e−13~75\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAmbient temp (Cooling)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e−13~122\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eUnit dimensions (W×H×D)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e37.24 × 16.14 × 31.89\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNet \/ Gross weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e122.13 \/ 132.28\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePacking dimensions (W×D×H)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e42.91 × 19.68 × 34.84\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRefrigerant precharge\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e25\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAdditional charge (3\/8\" liquid)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.32\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"hvx-desc-card\"\u003e\n\u003ch2 class=\"hvx-section-title\"\u003eDocuments \u0026amp; Downloads\u003c\/h2\u003e\n\u003cul style=\"padding-left: 18px; margin: 8px 0;\"\u003e\n\u003cli\u003e\u003ca class=\"hvx-link\" href=\"https:\/\/media.cooperandhunter.us\/4956\/CH-RES24-230VO-_-CH-RB24MOLVWM-230VI.pdf\" rel=\"noopener\" target=\"_blank\"\u003eSubmittal (PDF) — CH-RES24-230VO + CH-RB24MOLVWM-230VI\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca class=\"hvx-link\" href=\"https:\/\/media.cooperandhunter.us\/4961\/CH-RHP24-230VO_CH-RB24MOLVWM-230VI.pdf\" rel=\"noopener\" target=\"_blank\"\u003eSubmittal (PDF) — CH-RHP24-230VO + CH-RB24MOLVWM-230VI\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca class=\"hvx-link\" href=\"https:\/\/media.cooperandhunter.us\/4965\/CH-RB24MOLVWM-230VI.pdf\" rel=\"noopener\" target=\"_blank\"\u003eSubmittal (PDF) — CH-RB24MOLVWM-230VI\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca class=\"hvx-link\" href=\"https:\/\/media.cooperandhunter.us\/4159\/CH-RES24-230VO-%2B-CH-PRO24MASTWM-230VI.pdf\" rel=\"noopener\" target=\"_blank\"\u003eSubmittal (PDF) — CH-RES24-230VO + CH-PRO24MASTWM-230VI\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca class=\"hvx-link\" href=\"https:\/\/media.cooperandhunter.us\/4173\/CH-RES24-230VO-%2B-CH-RH24MASTWM-230VI.pdf\" rel=\"noopener\" target=\"_blank\"\u003eSubmittal (PDF) — CH-RES24-230VO + CH-RH24MASTWM-230VI\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca class=\"hvx-link\" href=\"https:\/\/media.cooperandhunter.us\/4212\/CH-RES24-230VO-%2B-CH-RS24MDT-HS.pdf\" rel=\"noopener\" target=\"_blank\"\u003eSubmittal (PDF) — CH-RES24-230VO + CH-RS24MDT-HS\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca class=\"hvx-link\" href=\"https:\/\/media.cooperandhunter.us\/4626\/CH-RES24-230VO_CH-RSH24MFC.pdf\" rel=\"noopener\" target=\"_blank\"\u003eSubmittal (PDF) — CH-RES24-230VO + CH-RSH24MFC\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca class=\"hvx-link\" href=\"https:\/\/media.cooperandhunter.us\/4680\/CH-RES24-230VO_CH-RH24MCT.pdf\" rel=\"noopener\" target=\"_blank\"\u003eSubmittal (PDF) — CH-RES24-230VO + CH-RH24MCT\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca class=\"hvx-link\" href=\"https:\/\/media.cooperandhunter.us\/4681\/CH-RES24-230VO_CH-RSH24MCT.pdf\" rel=\"noopener\" target=\"_blank\"\u003eSubmittal (PDF) — CH-RES24-230VO + CH-RSH24MCT\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca class=\"hvx-link\" href=\"https:\/\/media.cooperandhunter.us\/4118\/Installation-Manual-R454B-Outdoor-units--.pdf\" rel=\"noopener\" target=\"_blank\"\u003eInstallation Manual (PDF) — R454B Outdoor Units\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca class=\"hvx-link\" href=\"https:\/\/media.cooperandhunter.us\/4200\/SlimDuct-Leaflet-R454B.pdf\" rel=\"noopener\" target=\"_blank\"\u003eSlimDuct Leaflet (PDF) — R454B\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca class=\"hvx-link\" href=\"https:\/\/www.ahridirectory.org\/NewSearch?programId=41\u0026amp;searchTypeId=3\u0026amp;productTypeId=4\" rel=\"noopener\" target=\"_blank\"\u003eAHRI Directory\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca class=\"hvx-link\" href=\"https:\/\/cooperandhunter.us\/product\/ch-rb24molvwm-230vi\" rel=\"noopener\" target=\"_blank\"\u003eManufacturer Page — CH-RB24MOLVWM-230VI\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca class=\"hvx-link\" href=\"https:\/\/cooperandhunter.us\/product\/ch-res24-230vo\" rel=\"noopener\" target=\"_blank\"\u003eManufacturer Page — CH-RES24-230VO\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"hvx-desc-card\"\u003e\n\u003ch2 class=\"hvx-section-title\"\u003eImportant\u003c\/h2\u003e\n\u003cp style=\"margin: 0; font-size: 14px; color: var(--hvx-slate);\"\u003eProfessional installation is recommended. Verify electrical requirements, line sizes, maximum line length, and ambient operating limits before installation.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"hvx-desc-card\"\u003e\n\u003ch2 class=\"hvx-section-title\"\u003eFAQs\u003c\/h2\u003e\n\u003cdetails class=\"hvx-faq\" open=\"\"\u003e\n\u003csummary\u003eWhat voltage does this system require?\u003c\/summary\u003e\n\u003cdiv style=\"margin-top: 8px;\"\u003e208–230V, single phase, 60Hz.\u003c\/div\u003e\n\u003c\/details\u003e\n\u003cdetails class=\"hvx-faq\" open=\"\"\u003e\n\u003csummary\u003eWhat line sizes does this system use?\u003c\/summary\u003e\n\u003cdiv style=\"margin-top: 8px;\"\u003e3\/8\" liquid and 5\/8\" gas.\u003c\/div\u003e\n\u003c\/details\u003e\n\u003cdetails class=\"hvx-faq\" open=\"\"\u003e\n\u003csummary\u003eWhat is the max line length and height difference?\u003c\/summary\u003e\n\u003cdiv style=\"margin-top: 8px;\"\u003eMaximum line length is 164 ft and maximum height difference is 82.\u003c\/div\u003e\n\u003c\/details\u003e\n\u003cdetails class=\"hvx-faq\" open=\"\"\u003e\n\u003csummary\u003eWhat are the outdoor ambient operating ranges?\u003c\/summary\u003e\n\u003cdiv style=\"margin-top: 8px;\"\u003eCooling: −13~122. Heating: −13~75.\u003c\/div\u003e\n\u003c\/details\u003e\n\u003cdetails class=\"hvx-faq\" open=\"\"\u003e\n\u003csummary\u003eWhat refrigerant does this system use?\u003c\/summary\u003e\n\u003cdiv style=\"margin-top: 8px;\"\u003eR454B.\u003c\/div\u003e\n\u003c\/details\u003e\n\u003cdetails class=\"hvx-faq\" open=\"\"\u003e\n\u003csummary\u003eWhat control options are supported?\u003c\/summary\u003e\n\u003cdiv style=\"margin-top: 8px;\"\u003eSmart Kit app control and remote are supported; a wall thermostat can be purchased separately.\u003c\/div\u003e\n\u003c\/details\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e","brand":"Cooper\u0026Hunter","offers":[{"title":"No installation","offer_id":42690341470251,"sku":"CH-RB24MOLVWM-230VI + CH-RES24-230VO","price":1790.0,"currency_code":"USD","in_stock":true},{"title":"16FT","offer_id":42690341503019,"sku":"CH-RB24MOLVWM-230VI + CH-RES24-230VO","price":2006.0,"currency_code":"USD","in_stock":true},{"title":"25FT","offer_id":42690341535787,"sku":"CH-RB24MOLVWM-230VI + CH-RES24-230VO","price":2136.0,"currency_code":"USD","in_stock":true},{"title":"50FT","offer_id":42690341568555,"sku":"CH-RB24MOLVWM-230VI + CH-RES24-230VO","price":2442.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0625\/5647\/1339\/files\/Midnight_Bundle_1_1_e4edcfca-3bd5-4b28-88ee-89dc2ad3d459.jpg?v=1769199500"},{"product_id":"cooper-hunter-6-000-btu-mia-single-zone-wall-mount-minisplit-heat-pump-system-r454b-115v","title":"Cooper\u0026Hunter 6,000 BTU Mia Single Zone Wall Mount Minisplit Heat Pump System Includes 16FT Installation Kit R454B 115V","description":"\u003cstyle\u003e\n  :root{\n    --hvx-golden:#FAA819;\n    --hvx-slate:#262626;\n    --hvx-ivory:#F4F1E6;\n    --hvx-border:#e2e0d5;\n    --hvx-card-bg:#ffffff;\n  }\n\n  .hvx-desc{\n    font-family:\"Articulat CF\",system-ui,-apple-system,BlinkMacSystemFont,\"Segoe UI\",sans-serif;\n    color:var(--hvx-slate);\n    line-height:1.6;\n    background:var(--hvx-ivory);\n    padding:18px 18px 20px;\n    border-radius:16px;\n  }\n\n  .hvx-desc-header{\n    border-radius:14px;\n    padding:14px 16px;\n    background:linear-gradient(120deg,var(--hvx-golden),var(--hvx-slate));\n    color:#fff;\n    margin:0 0 16px;\n    box-shadow:0 10px 24px rgba(0,0,0,.22);\n    display:flex;\n    align-items:flex-start;\n    gap:12px;\n    flex-wrap:wrap;\n  }\n\n  .hvx-header-text{display:flex;flex-direction:column;gap:6px;min-width:260px}\n  .hvx-eyebrow{\n    font-size:11px;\n    letter-spacing:.14em;\n    text-transform:uppercase;\n    opacity:.9;\n  }\n  .hvx-title{\n    margin:0;\n    font-family:\"Anton\",\"Impact\",system-ui,-apple-system,BlinkMacSystemFont,\"Segoe UI\",sans-serif;\n    font-size:22px;\n    line-height:1.15;\n  }\n  .hvx-subtitle{margin:0;font-size:14px;opacity:.95}\n\n  .hvx-desc-card{\n    border:1px solid var(--hvx-border);\n    border-radius:14px;\n    background:var(--hvx-card-bg);\n    padding:16px 18px 18px;\n    box-shadow:0 4px 12px rgba(0,0,0,.06);\n    margin:14px 0;\n  }\n\n  .hvx-section-title{\n    margin:0 0 10px;\n    font-family:\"Anton\",\"Impact\",system-ui,-apple-system,BlinkMacSystemFont,\"Segoe UI\",sans-serif;\n    font-size:17px;\n    letter-spacing:.08em;\n    text-transform:uppercase;\n    color:var(--hvx-slate);\n    display:inline-flex;\n    align-items:center;\n    gap:8px;\n  }\n  .hvx-section-title::after{\n    content:\"\";\n    flex:1;\n    height:2px;\n    border-radius:999px;\n    background:linear-gradient(90deg,var(--hvx-golden),transparent);\n    opacity:.9;\n  }\n\n  .hvx-cta{display:flex;flex-wrap:wrap;gap:10px;margin:10px 0 0}\n  .hvx-cta a{\n    display:inline-flex;\n    align-items:center;\n    gap:8px;\n    padding:10px 14px;\n    border-radius:12px;\n    border:1px solid var(--hvx-border);\n    background:#fff;\n    text-decoration:none;\n    color:var(--hvx-slate);\n    font-size:14px;\n    font-weight:700;\n  }\n  .hvx-cta a.primary{\n    background:var(--hvx-slate);\n    color:#fff;\n    border-color:transparent;\n  }\n\n  .hvx-badges{display:flex;flex-wrap:wrap;gap:8px;margin:10px 0 0}\n  .hvx-badge{\n    font-size:12px;\n    border:1px solid var(--hvx-border);\n    border-radius:999px;\n    padding:6px 10px;\n    background:#fff;\n    white-space:nowrap;\n  }\n\n  .hvx-kv{\n    display:grid;\n    grid-template-columns:repeat(4,minmax(160px,1fr));\n    gap:10px;\n    margin-top:10px;\n  }\n  .hvx-kv \u003e div{\n    border:1px solid var(--hvx-border);\n    background:#fff;\n    border-radius:12px;\n    padding:10px 12px;\n    text-align:center;\n  }\n  .hvx-kv strong{display:block}\n\n  .hvx-table{\n    width:100%;\n    border-collapse:collapse;\n    min-width:520px;\n    background:#fff;\n    border:1px solid var(--hvx-border);\n    border-radius:12px;\n    overflow:hidden;\n  }\n  .hvx-table th,.hvx-table td{\n    border-bottom:1px solid var(--hvx-border);\n    padding:10px 12px;\n    vertical-align:top;\n    font-size:14px;\n  }\n  .hvx-table th{ text-align:left; font-weight:800; background:#fff; }\n  .hvx-table tr:nth-child(even) td{ background:#fbfaf6; }\n  .hvx-table tr:last-child td{ border-bottom:none; }\n  .hvx-table-wrap{ overflow:auto; border-radius:12px; }\n\n  .hvx-link{color:var(--hvx-slate); text-decoration:underline; text-underline-offset:2px}\n  .hvx-link:hover{opacity:.85}\n\n  details.hvx-faq{\n    border:1px solid var(--hvx-border);\n    background:#fff;\n    border-radius:12px;\n    padding:10px 12px;\n    margin:8px 0;\n  }\n  details.hvx-faq summary{cursor:pointer;font-weight:800}\n\n  @media(max-width:980px){\n    .hvx-kv{grid-template-columns:repeat(2,minmax(160px,1fr))}\n  }\n  @media(max-width:768px){\n    .hvx-desc{padding:14px 12px 16px;border-radius:12px}\n    .hvx-desc-header{padding:12px;border-radius:12px}\n    .hvx-title{font-size:19px}\n    .hvx-desc-card{padding:14px;margin:10px 0}\n  }\n\u003c\/style\u003e\n\u003cdiv class=\"hvx-desc\"\u003e\n\u003cdiv class=\"hvx-desc-header\"\u003e\n\u003cdiv class=\"hvx-header-text\"\u003e\n\u003cdiv class=\"hvx-eyebrow\"\u003eCooper\u0026amp;Hunter Mia NY • Matte Wall Mount • R454B • 115V\u003c\/div\u003e\n\u003ch1 class=\"hvx-title\"\u003eCooper\u0026amp;Hunter 6,000 BTU Mia Single Zone Wall Mount Minisplit Heat Pump System Includes 16FT Installation Kit R454B 115V\u003c\/h1\u003e\n\u003cp class=\"hvx-subtitle\"\u003e\u003cstrong\u003eSKU:\u003c\/strong\u003e CH-RLS06MIA-115VI + CH-RLS06MIA-115VO\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"hvx-cta\" aria-label=\"Contact options\"\u003e\n\u003ca class=\"primary\" href=\"https:\/\/hvacsupplies.com\/pages\/contact\" rel=\"noopener\" title=\"Contact Us\" target=\"_blank\"\u003e CLICK HERE TO CONTACT US FOR CUSTOM QUOTES AND QUESTIONS \u003c\/a\u003e \u003ca href=\"tel:+18005438933\" title=\"Call Us Now!\"\u003e CLICK TO CALL US 800-543-8933 FOR ANY QUESTIONS \u003c\/a\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"hvx-desc-card\"\u003e\n\u003ch2 class=\"hvx-section-title\"\u003eOverview\u003c\/h2\u003e\n\u003cp style=\"margin: 0;\"\u003eThe Cooper\u0026amp;Hunter \u003cstrong\u003eMia NY\u003c\/strong\u003e Series is an affordable, energy-efficient ductless solution for both cooling and heating. This entry-level wall-mount system features a sleek \u003cstrong\u003ematte\u003c\/strong\u003e indoor unit, \u003cstrong\u003einverter technology\u003c\/strong\u003e for efficient comfort, and modern features like \u003cstrong\u003eQuiet\/Silent operation\u003c\/strong\u003e, \u003cstrong\u003eSleep Mode\u003c\/strong\u003e, \u003cstrong\u003eAuto Swing\u003c\/strong\u003e horizontal louvers, and \u003cstrong\u003eWiFi compatibility\u003c\/strong\u003e via the included Smart Kit.\u003c\/p\u003e\n\u003cp style=\"margin: 10px 0 0;\"\u003eThis \u003cstrong\u003e6K (115V)\u003c\/strong\u003e single-zone pairing uses \u003cstrong\u003eR454B\u003c\/strong\u003e refrigerant and includes the essentials to get started, including the remote and manufacturer documentation. A \u003cstrong\u003e12V wall thermostat\u003c\/strong\u003e option is available (sold separately).\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"hvx-desc-card\"\u003e\n\u003ch2 class=\"hvx-section-title\"\u003eHighlights\u003c\/h2\u003e\n\u003cdiv class=\"hvx-badges\" role=\"list\"\u003e\n\u003cspan class=\"hvx-badge\" role=\"listitem\"\u003e6,000 BTU class\u003c\/span\u003e \u003cspan class=\"hvx-badge\" role=\"listitem\"\u003e115V system\u003c\/span\u003e \u003cspan class=\"hvx-badge\" role=\"listitem\"\u003eSingle-zone\u003c\/span\u003e \u003cspan class=\"hvx-badge\" role=\"listitem\"\u003eR454B refrigerant\u003c\/span\u003e \u003cspan class=\"hvx-badge\" role=\"listitem\"\u003eInverter technology\u003c\/span\u003e \u003cspan class=\"hvx-badge\" role=\"listitem\"\u003eSmart Kit and 16FT Installation Kit included\u003c\/span\u003e \u003cspan class=\"hvx-badge\" role=\"listitem\"\u003eAuto Swing (horizontal)\u003c\/span\u003e \u003cspan class=\"hvx-badge\" role=\"listitem\"\u003eSleep Mode\u003c\/span\u003e \u003cspan class=\"hvx-badge\" role=\"listitem\"\u003eSelf-clean function\u003c\/span\u003e \u003cspan class=\"hvx-badge\" role=\"listitem\"\u003eFollow Me\u003c\/span\u003e\n\u003c\/div\u003e\n\u003cul style=\"margin: 12px 0 0; padding-left: 18px;\"\u003e\n\u003cli\u003e\n\u003cstrong\u003eBudget-friendly comfort:\u003c\/strong\u003e Mia NY brings efficient inverter performance to an entry-level price point.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSmart control ready:\u003c\/strong\u003e Included Smart Kit supports app control (C\u0026amp;H app).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQuiet comfort:\u003c\/strong\u003e Silent\/Quiet function plus Sleep Mode for bedrooms and living spaces.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConvenience features:\u003c\/strong\u003e Turbo Function, LED display, multiple fan speeds, Follow Me, and Auto Swing louvers.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eControl options:\u003c\/strong\u003e Remote included; 12V wall thermostat compatible (sold separately).\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cdiv class=\"hvx-kv\" role=\"list\" aria-label=\"At-a-glance\"\u003e\n\u003cdiv role=\"listitem\"\u003e\n\u003cstrong\u003eIndoor\u003c\/strong\u003eCH-RLS06MIA-115VI\u003c\/div\u003e\n\u003cdiv role=\"listitem\"\u003e\n\u003cstrong\u003eOutdoor\u003c\/strong\u003eCH-RLS06MIA-115VO\u003c\/div\u003e\n\u003cdiv role=\"listitem\"\u003e\n\u003cstrong\u003eVoltage\u003c\/strong\u003e115V\u003c\/div\u003e\n\u003cdiv role=\"listitem\"\u003e\n\u003cstrong\u003eRefrigerant\u003c\/strong\u003eR454B\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"hvx-desc-card\"\u003e\n\u003ch2 class=\"hvx-section-title\"\u003eWhat’s Included\u003c\/h2\u003e\n\u003cul style=\"padding-left: 18px; margin: 8px 0;\"\u003e\n\u003cli\u003eIndoor unit: CH-RLS06MIA-115VI (Mia NY wall mount)\u003c\/li\u003e\n\u003cli\u003eOutdoor unit: CH-RLS06MIA-115VO\u003c\/li\u003e\n\u003cli\u003e16FT Installation Kit\u003c\/li\u003e\n\u003cli\u003eRemote control (included)\u003c\/li\u003e\n\u003cli\u003eSmart Kit for app control\u003c\/li\u003e\n\u003cli\u003eManufacturer documentation (see Documents \u0026amp; Downloads)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"hvx-desc-card\"\u003e\n\u003ch2 class=\"hvx-section-title\"\u003eIndoor Specs\u003c\/h2\u003e\n\u003cdiv class=\"hvx-table-wrap\"\u003e\n\u003ctable class=\"hvx-table\" aria-label=\"Indoor unit specifications\"\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eSpec\u003c\/th\u003e\n\u003cth\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCH-RLS06MIA-115VI\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSystem type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSingle Zone\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRefrigerant type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eR454B\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBTU rated\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e6,000\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower source\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e115V, 1Ph, 60Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eVoltage range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e103.5–126.5 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eController\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eRemote controller\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating range (Cooling)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e60–90\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating range (Heating)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e32–86\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eESP range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\/\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDrainage water pipe diameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e5\/8\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"hvx-desc-card\"\u003e\n\u003ch2 class=\"hvx-section-title\"\u003eOutdoor Specs\u003c\/h2\u003e\n\u003cdiv class=\"hvx-table-wrap\"\u003e\n\u003ctable class=\"hvx-table\" aria-label=\"Outdoor unit specifications\"\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eSpec\u003c\/th\u003e\n\u003cth\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCH-RLS06MIA-115VO\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRefrigerant type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eR454B\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBTU rated\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e6,000\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower source\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e115V, 1Ph, 60Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eVoltage range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e103.5–126.5 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCooling capacity (Min\/Max)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e9,000 (2,200~9,900)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eHeating capacity (Min\/Max)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e10,000 (4,200~10,200)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAmbient temp (Cooling)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e5~122\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAmbient temp (Heating)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e5~75\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRefrigerant precharge\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e25\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAdditional charge (1\/4\" liquid)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.16\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"hvx-desc-card\"\u003e\n\u003ch2 class=\"hvx-section-title\"\u003eDocuments \u0026amp; Downloads\u003c\/h2\u003e\n\u003cul style=\"padding-left: 18px; margin: 8px 0;\"\u003e\n\u003cli\u003e\u003ca class=\"hvx-link\" href=\"https:\/\/media.cooperandhunter.us\/4714\/CH-RLS06MIA-115VO_CH-RLS06MIA-115VI.pdf\" rel=\"noopener\" target=\"_blank\"\u003eSubmittal (PDF) — CH-RLS06MIA-115VO + CH-RLS06MIA-115VI\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca class=\"hvx-link\" href=\"https:\/\/media.cooperandhunter.us\/4722\/User_manual-MIA%28R454B%29.pdf\" rel=\"noopener\" target=\"_blank\"\u003eUser Manual (PDF) — MIA (R454B)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca class=\"hvx-link\" href=\"https:\/\/media.cooperandhunter.us\/4721\/Remote-controller-manual.pdf\" rel=\"noopener\" target=\"_blank\"\u003eRemote Controller Manual (PDF)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca class=\"hvx-link\" href=\"https:\/\/www.youtube.com\/watch?v=VV3-nC-sKrs\" rel=\"noopener\" target=\"_blank\"\u003eVideo — MIA Series\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca class=\"hvx-link\" href=\"https:\/\/cooperandhunter.us\/product\/ch-rls06mia-115vi\" rel=\"noopener\" target=\"_blank\"\u003eManufacturer Page — CH-RLS06MIA-115VI\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca class=\"hvx-link\" href=\"https:\/\/cooperandhunter.us\/product\/ch-rls06mia-115vo\" rel=\"noopener\" target=\"_blank\"\u003eManufacturer Page — CH-RLS06MIA-115VO\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"hvx-desc-card\"\u003e\n\u003ch2 class=\"hvx-section-title\"\u003eImportant\u003c\/h2\u003e\n\u003cp style=\"margin: 0; font-size: 14px; color: var(--hvx-slate);\"\u003eProfessional installation is recommended. Verify electrical requirements, voltage range, and ambient operating limits before installation.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"hvx-desc-card\"\u003e\n\u003ch2 class=\"hvx-section-title\"\u003eFAQs\u003c\/h2\u003e\n\u003cdetails class=\"hvx-faq\" open=\"\"\u003e\n\u003csummary\u003eWhat voltage does this system require?\u003c\/summary\u003e\n\u003cdiv style=\"margin-top: 8px;\"\u003e115V, single phase, 60Hz.\u003c\/div\u003e\n\u003c\/details\u003e\n\u003cdetails class=\"hvx-faq\" open=\"\"\u003e\n\u003csummary\u003eIs this system single-zone or multi-zone?\u003c\/summary\u003e\n\u003cdiv style=\"margin-top: 8px;\"\u003eSingle-zone (one-to-one only).\u003c\/div\u003e\n\u003c\/details\u003e\n\u003cdetails class=\"hvx-faq\" open=\"\"\u003e\n\u003csummary\u003eWhat refrigerant does it use?\u003c\/summary\u003e\n\u003cdiv style=\"margin-top: 8px;\"\u003eR454B.\u003c\/div\u003e\n\u003c\/details\u003e\n\u003cdetails class=\"hvx-faq\" open=\"\"\u003e\n\u003csummary\u003eWhat are the indoor operating ranges?\u003c\/summary\u003e\n\u003cdiv style=\"margin-top: 8px;\"\u003eCooling: 60–90. Heating: 32–86.\u003c\/div\u003e\n\u003c\/details\u003e\n\u003cdetails class=\"hvx-faq\" open=\"\"\u003e\n\u003csummary\u003eWhat are the outdoor ambient operating ranges?\u003c\/summary\u003e\n\u003cdiv style=\"margin-top: 8px;\"\u003eCooling: 5–122. Heating: 5–75.\u003c\/div\u003e\n\u003c\/details\u003e\n\u003cdetails class=\"hvx-faq\" open=\"\"\u003e\n\u003csummary\u003eWhat control options are supported?\u003c\/summary\u003e\n\u003cdiv style=\"margin-top: 8px;\"\u003eRemote and Smart Kit app control are supported; 12V wall thermostat is optional (sold separately).\u003c\/div\u003e\n\u003c\/details\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e","brand":"Cooper\u0026Hunter","offers":[{"title":"Default Title","offer_id":42690364538923,"sku":"CH-RLS06MIA-115VI + CH-RLS06MIA-115VO","price":820.8,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0625\/5647\/1339\/files\/24K230V_6edb26d4-f69a-4c32-8a6d-d082397032c7.png?v=1769199376"},{"product_id":"cooper-hunter-9-000-btu-mia-single-zone-wall-mount-minisplit-heat-pump-system-includes-16ft-installation-kit-r454b-115v","title":"Cooper\u0026Hunter 9,000 BTU Mia Single Zone Wall Mount Minisplit Heat Pump System Includes 16FT Installation Kit R454B 115V","description":"\u003cstyle\u003e\n  :root{\n    --hvx-golden:#FAA819;\n    --hvx-slate:#262626;\n    --hvx-ivory:#F4F1E6;\n    --hvx-border:#e2e0d5;\n    --hvx-card-bg:#ffffff;\n  }\n\n  .hvx-desc{\n    font-family:\"Articulat CF\",system-ui,-apple-system,BlinkMacSystemFont,\"Segoe UI\",sans-serif;\n    color:var(--hvx-slate);\n    line-height:1.6;\n    background:var(--hvx-ivory);\n    padding:18px 18px 20px;\n    border-radius:16px;\n  }\n\n  .hvx-desc-header{\n    border-radius:14px;\n    padding:14px 16px;\n    background:linear-gradient(120deg,var(--hvx-golden),var(--hvx-slate));\n    color:#fff;\n    margin:0 0 16px;\n    box-shadow:0 10px 24px rgba(0,0,0,.22);\n    display:flex;\n    align-items:flex-start;\n    gap:12px;\n    flex-wrap:wrap;\n  }\n\n  .hvx-header-text{display:flex;flex-direction:column;gap:6px;min-width:260px}\n  .hvx-eyebrow{\n    font-size:11px;\n    letter-spacing:.14em;\n    text-transform:uppercase;\n    opacity:.9;\n  }\n  .hvx-title{\n    margin:0;\n    font-family:\"Anton\",\"Impact\",system-ui,-apple-system,BlinkMacSystemFont,\"Segoe UI\",sans-serif;\n    font-size:22px;\n    line-height:1.15;\n  }\n  .hvx-subtitle{margin:0;font-size:14px;opacity:.95}\n\n  .hvx-desc-card{\n    border:1px solid var(--hvx-border);\n    border-radius:14px;\n    background:var(--hvx-card-bg);\n    padding:16px 18px 18px;\n    box-shadow:0 4px 12px rgba(0,0,0,.06);\n    margin:14px 0;\n  }\n\n  .hvx-section-title{\n    margin:0 0 10px;\n    font-family:\"Anton\",\"Impact\",system-ui,-apple-system,BlinkMacSystemFont,\"Segoe UI\",sans-serif;\n    font-size:17px;\n    letter-spacing:.08em;\n    text-transform:uppercase;\n    color:var(--hvx-slate);\n    display:inline-flex;\n    align-items:center;\n    gap:8px;\n  }\n  .hvx-section-title::after{\n    content:\"\";\n    flex:1;\n    height:2px;\n    border-radius:999px;\n    background:linear-gradient(90deg,var(--hvx-golden),transparent);\n    opacity:.9;\n  }\n\n  .hvx-cta{display:flex;flex-wrap:wrap;gap:10px;margin:10px 0 0}\n  .hvx-cta a{\n    display:inline-flex;\n    align-items:center;\n    gap:8px;\n    padding:10px 14px;\n    border-radius:12px;\n    border:1px solid var(--hvx-border);\n    background:#fff;\n    text-decoration:none;\n    color:var(--hvx-slate);\n    font-size:14px;\n    font-weight:700;\n  }\n  .hvx-cta a.primary{\n    background:var(--hvx-slate);\n    color:#fff;\n    border-color:transparent;\n  }\n\n  .hvx-badges{display:flex;flex-wrap:wrap;gap:8px;margin:10px 0 0}\n  .hvx-badge{\n    font-size:12px;\n    border:1px solid var(--hvx-border);\n    border-radius:999px;\n    padding:6px 10px;\n    background:#fff;\n    white-space:nowrap;\n  }\n\n  .hvx-kv{\n    display:grid;\n    grid-template-columns:repeat(4,minmax(160px,1fr));\n    gap:10px;\n    margin-top:10px;\n  }\n  .hvx-kv \u003e div{\n    border:1px solid var(--hvx-border);\n    background:#fff;\n    border-radius:12px;\n    padding:10px 12px;\n    text-align:center;\n  }\n  .hvx-kv strong{display:block}\n\n  .hvx-table{\n    width:100%;\n    border-collapse:collapse;\n    min-width:520px;\n    background:#fff;\n    border:1px solid var(--hvx-border);\n    border-radius:12px;\n    overflow:hidden;\n  }\n  .hvx-table th,.hvx-table td{\n    border-bottom:1px solid var(--hvx-border);\n    padding:10px 12px;\n    vertical-align:top;\n    font-size:14px;\n  }\n  .hvx-table th{ text-align:left; font-weight:800; background:#fff; }\n  .hvx-table tr:nth-child(even) td{ background:#fbfaf6; }\n  .hvx-table tr:last-child td{ border-bottom:none; }\n  .hvx-table-wrap{ overflow:auto; border-radius:12px; }\n\n  .hvx-link{color:var(--hvx-slate); text-decoration:underline; text-underline-offset:2px}\n  .hvx-link:hover{opacity:.85}\n\n  details.hvx-faq{\n    border:1px solid var(--hvx-border);\n    background:#fff;\n    border-radius:12px;\n    padding:10px 12px;\n    margin:8px 0;\n  }\n  details.hvx-faq summary{cursor:pointer;font-weight:800}\n\n  @media(max-width:980px){\n    .hvx-kv{grid-template-columns:repeat(2,minmax(160px,1fr))}\n  }\n  @media(max-width:768px){\n    .hvx-desc{padding:14px 12px 16px;border-radius:12px}\n    .hvx-desc-header{padding:12px;border-radius:12px}\n    .hvx-title{font-size:19px}\n    .hvx-desc-card{padding:14px;margin:10px 0}\n  }\n\u003c\/style\u003e\n\u003cdiv class=\"hvx-desc\"\u003e\n\u003cdiv class=\"hvx-desc-header\"\u003e\n\u003cdiv class=\"hvx-header-text\"\u003e\n\u003cdiv class=\"hvx-eyebrow\"\u003eCooper\u0026amp;Hunter MIA • Matte • R454B • 115V\u003c\/div\u003e\n\u003ch1 class=\"hvx-title\"\u003eCooper\u0026amp;Hunter 9,000 BTU MIA Single Zone Wall Mount Mini Split Heat Pump System R454B 115V\u003c\/h1\u003e\n\u003cp class=\"hvx-subtitle\"\u003e\u003cstrong\u003eSKU:\u003c\/strong\u003e CH-RLS09MIA-115VI + CH-RLS09MIA-115VO\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"hvx-cta\" aria-label=\"Contact options\"\u003e\n\u003ca class=\"primary\" href=\"https:\/\/hvacsupplies.com\/pages\/contact\" rel=\"noopener\" title=\"Contact Us\" target=\"_blank\"\u003e CLICK HERE TO CONTACT US FOR CUSTOM QUOTES AND QUESTIONS \u003c\/a\u003e \u003ca href=\"tel:+18005438933\" title=\"Call Us Now!\"\u003e CLICK TO CALL US 800-543-8933 FOR ANY QUESTIONS \u003c\/a\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"hvx-desc-card\"\u003e\n\u003ch2 class=\"hvx-section-title\"\u003eOverview\u003c\/h2\u003e\n\u003cp style=\"margin: 0;\"\u003eThe Cooper\u0026amp;Hunter \u003cstrong\u003e9K BTU 115V MIA\u003c\/strong\u003e wall-mounted mini split is a one-to-one, \u003cstrong\u003esingle-zone\u003c\/strong\u003e comfort solution for smaller rooms. Built around \u003cstrong\u003eR454B refrigerant\u003c\/strong\u003e and \u003cstrong\u003einverter technology\u003c\/strong\u003e, MIA delivers efficient heating and cooling with a sleek \u003cstrong\u003ematte-finish\u003c\/strong\u003e indoor unit and modern convenience features.\u003c\/p\u003e\n\u003cp style=\"margin: 10px 0 0;\"\u003eComfort and control features include \u003cstrong\u003eTurbo\u003c\/strong\u003e for fast temperature changes, \u003cstrong\u003eSilent\u003c\/strong\u003e mode for quiet operation, \u003cstrong\u003eAuto Swing\u003c\/strong\u003e horizontal louvers for even airflow, \u003cstrong\u003eSleep Mode\u003c\/strong\u003e, \u003cstrong\u003emultiple fan speeds\u003c\/strong\u003e, \u003cstrong\u003eSelf-Cleaning\u003c\/strong\u003e, and \u003cstrong\u003eFollow Me\u003c\/strong\u003e temperature sensing from the remote. MIA series coils are protected with \u003cstrong\u003eGoldFin\u003c\/strong\u003e anti-corrosive coating, and the system is \u003cstrong\u003eWiFi ready\u003c\/strong\u003e with the included Smart Kit and C\u0026amp;H app support.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"hvx-desc-card\"\u003e\n\u003ch2 class=\"hvx-section-title\"\u003eHighlights\u003c\/h2\u003e\n\u003cdiv class=\"hvx-badges\" role=\"list\"\u003e\n\u003cspan class=\"hvx-badge\" role=\"listitem\"\u003e9,000 BTU class\u003c\/span\u003e \u003cspan class=\"hvx-badge\" role=\"listitem\"\u003e115V system\u003c\/span\u003e \u003cspan class=\"hvx-badge\" role=\"listitem\"\u003eSingle-zone (one-to-one)\u003c\/span\u003e \u003cspan class=\"hvx-badge\" role=\"listitem\"\u003eR454B refrigerant\u003c\/span\u003e \u003cspan class=\"hvx-badge\" role=\"listitem\"\u003eSEER2 21.5\u003c\/span\u003e \u003cspan class=\"hvx-badge\" role=\"listitem\"\u003eEER2 12.5\u003c\/span\u003e \u003cspan class=\"hvx-badge\" role=\"listitem\"\u003eInverter technology\u003c\/span\u003e \u003cspan class=\"hvx-badge\" role=\"listitem\"\u003eSmart Kit and 16FT IInstallation Kit included\u003c\/span\u003e \u003cspan class=\"hvx-badge\" role=\"listitem\"\u003eGoldFin coil protection\u003c\/span\u003e \u003cspan class=\"hvx-badge\" role=\"listitem\"\u003eAuto Swing (horizontal)\u003c\/span\u003e\n\u003c\/div\u003e\n\u003cul style=\"margin: 12px 0 0; padding-left: 18px;\"\u003e\n\u003cli\u003e\n\u003cstrong\u003eEfficient comfort:\u003c\/strong\u003e Inverter-driven performance helps maintain steady temperatures with lower energy use.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQuiet operation:\u003c\/strong\u003e Silent mode plus Sleep Mode for bedrooms and living spaces.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEven air distribution:\u003c\/strong\u003e Auto Swing horizontal louvers help reduce hot\/cold spots.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSmart control ready:\u003c\/strong\u003e Included Smart Kit supports app control (C\u0026amp;H app).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDurable build:\u003c\/strong\u003e TU1 copper tubing and GoldFin anti-corrosive coating.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eControl options:\u003c\/strong\u003e Remote included; 12V wall thermostat compatible (sold separately).\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cdiv class=\"hvx-kv\" role=\"list\" aria-label=\"At-a-glance\"\u003e\n\u003cdiv role=\"listitem\"\u003e\n\u003cstrong\u003eIndoor\u003c\/strong\u003eCH-RLS09MIA-115VI\u003c\/div\u003e\n\u003cdiv role=\"listitem\"\u003e\n\u003cstrong\u003eOutdoor\u003c\/strong\u003eCH-RLS09MIA-115VO\u003c\/div\u003e\n\u003cdiv role=\"listitem\"\u003e\n\u003cstrong\u003eLines\u003c\/strong\u003e1\/4\" liquid · 3\/8\" gas\u003c\/div\u003e\n\u003cdiv role=\"listitem\"\u003e\n\u003cstrong\u003eMax run\u003c\/strong\u003e82 ft\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"hvx-desc-card\"\u003e\n\u003ch2 class=\"hvx-section-title\"\u003eWhat’s Included\u003c\/h2\u003e\n\u003cul style=\"padding-left: 18px; margin: 8px 0;\"\u003e\n\u003cli\u003eIndoor unit: CH-RLS09MIA-115VI (MIA wall mount, matte finish)\u003c\/li\u003e\n\u003cli\u003eOutdoor unit: CH-RLS09MIA-115VO\u003c\/li\u003e\n\u003cli\u003e16FT Installation Kit\u003c\/li\u003e\n\u003cli\u003eRemote control (included)\u003c\/li\u003e\n\u003cli\u003eSmart Kit for app control\u003c\/li\u003e\n\u003cli\u003eManufacturer documentation (see Documents \u0026amp; Downloads)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"hvx-desc-card\"\u003e\n\u003ch2 class=\"hvx-section-title\"\u003eIndoor Specs\u003c\/h2\u003e\n\u003cdiv class=\"hvx-table-wrap\"\u003e\n\u003ctable class=\"hvx-table\" aria-label=\"Indoor unit specifications\"\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eSpec\u003c\/th\u003e\n\u003cth\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCH-RLS09MIA-115VI\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSystem type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSingle Zone\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRefrigerant type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eR454B\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBTU rated\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e9,000\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower source\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e115V, 1Ph, 60Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eVoltage range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e103.5–126.5 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSEER2\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e21.5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEER2\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e12.5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDehumidification\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2.11 pnt\/day\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRefrigerant piping (liq\/gas)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1\/4\" \/ 3\/8\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMinimum circuit ampacity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMax fuse\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e15\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIndoor noise level (H\/M\/L)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e37.5 \/ 33.5 \/ 25\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIndoor air flow\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e282.5 \/ 235.4 \/ 206 \/ 164.8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eUnit dimensions (W×H×D)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e28.43 × 7.36 × 11.42\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePacking dimensions (W×D×H)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e31.10 × 10.63 × 14.76\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNet \/ Gross weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e17.42 \/ 22.93\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating range (Cooling)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e60–90\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating range (Heating)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e32–86\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDrainage water pipe diameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e5\/8\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eESP range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\/\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFilter dimensions (W×D)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\/\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eController\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eRemote controller\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"hvx-desc-card\"\u003e\n\u003ch2 class=\"hvx-section-title\"\u003eOutdoor Specs\u003c\/h2\u003e\n\u003cdiv class=\"hvx-table-wrap\"\u003e\n\u003ctable class=\"hvx-table\" aria-label=\"Outdoor unit specifications\"\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eSpec\u003c\/th\u003e\n\u003cth\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCH-RLS09MIA-115VO\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRefrigerant type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eR454B\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBTU rated\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e9,000\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower source\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e115V, 1Ph, 60Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eVoltage range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e103.5–126.5 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMax pipe length\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e82 ft\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMax height difference (IDU↔ODU)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e49.2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRefrigerant piping (liq\/gas)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1\/4\" \/ 3\/8\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCooling capacity (Min\/Max)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e9,000 (2,200~9,900)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eHeating capacity (Min\/Max)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e10,000 (4,200~10,200)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eHSPF2-5\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e7\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eHSPF2-4\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e9\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCOP\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3.29\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDehumidification\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2.11 pnt\/day\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOutdoor noise level\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e52.5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOutdoor air flow\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1,294\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMinimum circuit ampacity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e18\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMax fuse\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAmbient temp (Cooling)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e5~122\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAmbient temp (Heating)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e5~75\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eUnit dimensions (W×H×D)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e30.12 × 11.93 × 21.85\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNet \/ Gross weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e56.66 \/ 62.17\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePacking dimensions (W×D×H)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e34.84 × 14.76 × 23.82\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRefrigerant precharge\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e25\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAdditional charge (1\/4\" liquid)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.16\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAdditional charge (3\/8\" liquid)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\/\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"hvx-desc-card\"\u003e\n\u003ch2 class=\"hvx-section-title\"\u003eDocuments \u0026amp; Downloads\u003c\/h2\u003e\n\u003cul style=\"padding-left: 18px; margin: 8px 0;\"\u003e\n\u003cli\u003e\u003ca class=\"hvx-link\" href=\"https:\/\/media.cooperandhunter.us\/4715\/CH-RLS09MIA-115VO_CH-RLS09MIA-115VI.pdf\" rel=\"noopener\" target=\"_blank\"\u003eSubmittal (PDF) — CH-RLS09MIA-115VO + CH-RLS09MIA-115VI\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca class=\"hvx-link\" href=\"https:\/\/media.cooperandhunter.us\/4722\/User_manual-MIA%28R454B%29.pdf\" rel=\"noopener\" target=\"_blank\"\u003eUser Manual (PDF) — MIA (R454B)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca class=\"hvx-link\" href=\"https:\/\/media.cooperandhunter.us\/4721\/Remote-controller-manual.pdf\" rel=\"noopener\" target=\"_blank\"\u003eRemote Controller Manual (PDF)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca class=\"hvx-link\" href=\"https:\/\/www.youtube.com\/watch?v=VV3-nC-sKrs\" rel=\"noopener\" target=\"_blank\"\u003eVideo — MIA Series\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca class=\"hvx-link\" href=\"https:\/\/www.ahridirectory.org\/NewSearch?programId=41\u0026amp;searchTypeId=3\u0026amp;productTypeId=4\" rel=\"noopener\" target=\"_blank\"\u003eAHRI Directory\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca class=\"hvx-link\" href=\"https:\/\/cooperandhunter.us\/product\/ch-rls09mia-115vi\" rel=\"noopener\" target=\"_blank\"\u003eManufacturer Page — CH-RLS09MIA-115VI\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca class=\"hvx-link\" href=\"https:\/\/cooperandhunter.us\/product\/ch-rls09mia-115vo\" rel=\"noopener\" target=\"_blank\"\u003eManufacturer Page — CH-RLS09MIA-115VO\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"hvx-desc-card\"\u003e\n\u003ch2 class=\"hvx-section-title\"\u003eImportant\u003c\/h2\u003e\n\u003cp style=\"margin: 0; font-size: 14px; color: var(--hvx-slate);\"\u003eProfessional installation is recommended. Confirm electrical requirements, line sizes, maximum line length, and ambient operating limits before installation.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"hvx-desc-card\"\u003e\n\u003ch2 class=\"hvx-section-title\"\u003eFAQs\u003c\/h2\u003e\n\u003cdetails class=\"hvx-faq\" open=\"\"\u003e\n\u003csummary\u003eWhat voltage does this system require?\u003c\/summary\u003e\n\u003cdiv style=\"margin-top: 8px;\"\u003e115V, single phase, 60Hz.\u003c\/div\u003e\n\u003c\/details\u003e\n\u003cdetails class=\"hvx-faq\" open=\"\"\u003e\n\u003csummary\u003eIs this system single-zone or multi-zone?\u003c\/summary\u003e\n\u003cdiv style=\"margin-top: 8px;\"\u003eSingle-zone (one-to-one).\u003c\/div\u003e\n\u003c\/details\u003e\n\u003cdetails class=\"hvx-faq\" open=\"\"\u003e\n\u003csummary\u003eWhat line sizes does this system use?\u003c\/summary\u003e\n\u003cdiv style=\"margin-top: 8px;\"\u003e1\/4\" liquid and 3\/8\" gas.\u003c\/div\u003e\n\u003c\/details\u003e\n\u003cdetails class=\"hvx-faq\" open=\"\"\u003e\n\u003csummary\u003eWhat is the max line length and height difference?\u003c\/summary\u003e\n\u003cdiv style=\"margin-top: 8px;\"\u003eMaximum line length is 82 ft and maximum height difference is 49.2.\u003c\/div\u003e\n\u003c\/details\u003e\n\u003cdetails class=\"hvx-faq\" open=\"\"\u003e\n\u003csummary\u003eWhat are the outdoor ambient operating ranges?\u003c\/summary\u003e\n\u003cdiv style=\"margin-top: 8px;\"\u003eCooling: 5~122. Heating: 5~75.\u003c\/div\u003e\n\u003c\/details\u003e\n\u003cdetails class=\"hvx-faq\" open=\"\"\u003e\n\u003csummary\u003eWhat control options are supported?\u003c\/summary\u003e\n\u003cdiv style=\"margin-top: 8px;\"\u003eSmart Kit app control and remote are supported; a 12V wall thermostat can be purchased separately.\u003c\/div\u003e\n\u003c\/details\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e","brand":"Cooper\u0026Hunter","offers":[{"title":"Default Title","offer_id":42690422964267,"sku":"CH-RLS09MIA-115VI + CH-RLS09MIA-115VO","price":830.88,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0625\/5647\/1339\/files\/24K230V_6edb26d4-f69a-4c32-8a6d-d082397032c7.png?v=1769199376"},{"product_id":"cooper-hunter-12-000-btu-mia-single-zone-wall-mount-minisplit-heat-pump-system-includes-16ft-installation-kit-r454b-115v","title":"Cooper\u0026Hunter 12,000 BTU Mia Single Zone Wall Mount Minisplit Heat Pump System Includes 16FT Installation Kit R454B 115V","description":"\u003cstyle\u003e\n  :root{\n    --hvx-golden:#FAA819;\n    --hvx-slate:#262626;\n    --hvx-ivory:#F4F1E6;\n    --hvx-border:#e2e0d5;\n    --hvx-card-bg:#ffffff;\n  }\n\n  .hvx-desc{\n    font-family:\"Articulat CF\",system-ui,-apple-system,BlinkMacSystemFont,\"Segoe UI\",sans-serif;\n    color:var(--hvx-slate);\n    line-height:1.6;\n    background:var(--hvx-ivory);\n    padding:18px 18px 20px;\n    border-radius:16px;\n  }\n\n  .hvx-desc-header{\n    border-radius:14px;\n    padding:14px 16px;\n    background:linear-gradient(120deg,var(--hvx-golden),var(--hvx-slate));\n    color:#fff;\n    margin:0 0 16px;\n    box-shadow:0 10px 24px rgba(0,0,0,.22);\n    display:flex;\n    align-items:flex-start;\n    gap:12px;\n    flex-wrap:wrap;\n  }\n\n  .hvx-header-text{display:flex;flex-direction:column;gap:6px;min-width:260px}\n  .hvx-eyebrow{\n    font-size:11px;\n    letter-spacing:.14em;\n    text-transform:uppercase;\n    opacity:.9;\n  }\n  .hvx-title{\n    margin:0;\n    font-family:\"Anton\",\"Impact\",system-ui,-apple-system,BlinkMacSystemFont,\"Segoe UI\",sans-serif;\n    font-size:22px;\n    line-height:1.15;\n  }\n  .hvx-subtitle{margin:0;font-size:14px;opacity:.95}\n\n  .hvx-desc-card{\n    border:1px solid var(--hvx-border);\n    border-radius:14px;\n    background:var(--hvx-card-bg);\n    padding:16px 18px 18px;\n    box-shadow:0 4px 12px rgba(0,0,0,.06);\n    margin:14px 0;\n  }\n\n  .hvx-section-title{\n    margin:0 0 10px;\n    font-family:\"Anton\",\"Impact\",system-ui,-apple-system,BlinkMacSystemFont,\"Segoe UI\",sans-serif;\n    font-size:17px;\n    letter-spacing:.08em;\n    text-transform:uppercase;\n    color:var(--hvx-slate);\n    display:inline-flex;\n    align-items:center;\n    gap:8px;\n  }\n  .hvx-section-title::after{\n    content:\"\";\n    flex:1;\n    height:2px;\n    border-radius:999px;\n    background:linear-gradient(90deg,var(--hvx-golden),transparent);\n    opacity:.9;\n  }\n\n  .hvx-cta{display:flex;flex-wrap:wrap;gap:10px;margin:10px 0 0}\n  .hvx-cta a{\n    display:inline-flex;\n    align-items:center;\n    gap:8px;\n    padding:10px 14px;\n    border-radius:12px;\n    border:1px solid var(--hvx-border);\n    background:#fff;\n    text-decoration:none;\n    color:var(--hvx-slate);\n    font-size:14px;\n    font-weight:700;\n  }\n  .hvx-cta a.primary{\n    background:var(--hvx-slate);\n    color:#fff;\n    border-color:transparent;\n  }\n\n  .hvx-badges{display:flex;flex-wrap:wrap;gap:8px;margin:10px 0 0}\n  .hvx-badge{\n    font-size:12px;\n    border:1px solid var(--hvx-border);\n    border-radius:999px;\n    padding:6px 10px;\n    background:#fff;\n    white-space:nowrap;\n  }\n\n  .hvx-kv{\n    display:grid;\n    grid-template-columns:repeat(4,minmax(160px,1fr));\n    gap:10px;\n    margin-top:10px;\n  }\n  .hvx-kv \u003e div{\n    border:1px solid var(--hvx-border);\n    background:#fff;\n    border-radius:12px;\n    padding:10px 12px;\n    text-align:center;\n  }\n  .hvx-kv strong{display:block}\n\n  .hvx-table{\n    width:100%;\n    border-collapse:collapse;\n    min-width:520px;\n    background:#fff;\n    border:1px solid var(--hvx-border);\n    border-radius:12px;\n    overflow:hidden;\n  }\n  .hvx-table th,.hvx-table td{\n    border-bottom:1px solid var(--hvx-border);\n    padding:10px 12px;\n    vertical-align:top;\n    font-size:14px;\n  }\n  .hvx-table th{ text-align:left; font-weight:800; background:#fff; }\n  .hvx-table tr:nth-child(even) td{ background:#fbfaf6; }\n  .hvx-table tr:last-child td{ border-bottom:none; }\n  .hvx-table-wrap{ overflow:auto; border-radius:12px; }\n\n  .hvx-link{color:var(--hvx-slate); text-decoration:underline; text-underline-offset:2px}\n  .hvx-link:hover{opacity:.85}\n\n  details.hvx-faq{\n    border:1px solid var(--hvx-border);\n    background:#fff;\n    border-radius:12px;\n    padding:10px 12px;\n    margin:8px 0;\n  }\n  details.hvx-faq summary{cursor:pointer;font-weight:800}\n\n  @media(max-width:980px){\n    .hvx-kv{grid-template-columns:repeat(2,minmax(160px,1fr))}\n  }\n  @media(max-width:768px){\n    .hvx-desc{padding:14px 12px 16px;border-radius:12px}\n    .hvx-desc-header{padding:12px;border-radius:12px}\n    .hvx-title{font-size:19px}\n    .hvx-desc-card{padding:14px;margin:10px 0}\n  }\n\u003c\/style\u003e\n\u003cdiv class=\"hvx-desc\"\u003e\n\u003cdiv class=\"hvx-desc-header\"\u003e\n\u003cdiv class=\"hvx-header-text\"\u003e\n\u003cdiv class=\"hvx-eyebrow\"\u003eCooper\u0026amp;Hunter MIA • Matte • R454B • 115V\u003c\/div\u003e\n\u003ch1 class=\"hvx-title\"\u003eCooper\u0026amp;Hunter 12,000 BTU MIA Single Zone Wall Mount Mini Split Heat Pump System R454B 115V\u003c\/h1\u003e\n\u003cp class=\"hvx-subtitle\"\u003e\u003cstrong\u003eSKU:\u003c\/strong\u003e CH-RLS12MIA-115VI + CH-RLS12MIA-115VO\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"hvx-cta\" aria-label=\"Contact options\"\u003e\n\u003ca class=\"primary\" href=\"https:\/\/hvacsupplies.com\/pages\/contact\" rel=\"noopener\" title=\"Contact Us\" target=\"_blank\"\u003e CLICK HERE TO CONTACT US FOR CUSTOM QUOTES AND QUESTIONS \u003c\/a\u003e \u003ca href=\"tel:+18005438933\" title=\"Call Us Now!\"\u003e CLICK TO CALL US 800-543-8933 FOR ANY QUESTIONS \u003c\/a\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"hvx-desc-card\"\u003e\n\u003ch2 class=\"hvx-section-title\"\u003eOverview\u003c\/h2\u003e\n\u003cp style=\"margin: 0;\"\u003eThe Cooper\u0026amp;Hunter \u003cstrong\u003e12K BTU 115V MIA\u003c\/strong\u003e wall-mounted mini split is a one-to-one, \u003cstrong\u003esingle-zone\u003c\/strong\u003e heating and cooling solution built for smaller rooms and compact spaces. It uses the new \u003cstrong\u003eR454B refrigerant\u003c\/strong\u003e and a sleek \u003cstrong\u003ematte-finish\u003c\/strong\u003e indoor unit that blends into modern interiors.\u003c\/p\u003e\n\u003cp style=\"margin: 10px 0 0;\"\u003eComfort and convenience features include \u003cstrong\u003einverter technology\u003c\/strong\u003e for efficient operation, \u003cstrong\u003eTurbo\u003c\/strong\u003e for rapid heating\/cooling, \u003cstrong\u003eSilent\u003c\/strong\u003e function, \u003cstrong\u003eLED display\u003c\/strong\u003e, \u003cstrong\u003eAuto Swing\u003c\/strong\u003e horizontal louvers for even air distribution, \u003cstrong\u003eSleep Mode\u003c\/strong\u003e, \u003cstrong\u003emultiple fan speeds\u003c\/strong\u003e, \u003cstrong\u003eSelf-Cleaning\u003c\/strong\u003e, and \u003cstrong\u003eFollow Me\u003c\/strong\u003e sensing from the remote. MIA series coils are protected by \u003cstrong\u003eGoldFin\u003c\/strong\u003e anti-corrosive coating, and the included \u003cstrong\u003eSmart Kit\u003c\/strong\u003e supports app control with the C\u0026amp;H app. TU1 copper tubing helps support durability and heat transfer. The package includes a \u003cstrong\u003eline set\u003c\/strong\u003e, \u003cstrong\u003e16 ft communication cable\u003c\/strong\u003e, and \u003cstrong\u003edrain line\u003c\/strong\u003e for easier installation.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"hvx-desc-card\"\u003e\n\u003ch2 class=\"hvx-section-title\"\u003eHighlights\u003c\/h2\u003e\n\u003cdiv class=\"hvx-badges\" role=\"list\"\u003e\n\u003cspan class=\"hvx-badge\" role=\"listitem\"\u003e12,000 BTU class\u003c\/span\u003e \u003cspan class=\"hvx-badge\" role=\"listitem\"\u003e115V system\u003c\/span\u003e \u003cspan class=\"hvx-badge\" role=\"listitem\"\u003eSingle-zone (one-to-one)\u003c\/span\u003e \u003cspan class=\"hvx-badge\" role=\"listitem\"\u003eR454B refrigerant\u003c\/span\u003e \u003cspan class=\"hvx-badge\" role=\"listitem\"\u003eSEER2 21.2\u003c\/span\u003e \u003cspan class=\"hvx-badge\" role=\"listitem\"\u003eEER2 10.1\u003c\/span\u003e \u003cspan class=\"hvx-badge\" role=\"listitem\"\u003eInverter technology\u003c\/span\u003e \u003cspan class=\"hvx-badge\" role=\"listitem\"\u003eSmart Kit included\u003c\/span\u003e \u003cspan class=\"hvx-badge\" role=\"listitem\"\u003eGoldFin coil protection\u003c\/span\u003e \u003cspan class=\"hvx-badge\" role=\"listitem\"\u003eAuto Swing (horizontal)\u003c\/span\u003e\n\u003c\/div\u003e\n\u003cul style=\"margin: 12px 0 0; padding-left: 18px;\"\u003e\n\u003cli\u003e\n\u003cstrong\u003eEfficient comfort:\u003c\/strong\u003e Inverter-driven performance helps maintain steady temperatures while reducing energy use.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFast adjustments:\u003c\/strong\u003e Turbo mode for quick heating and cooling changes.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQuiet living:\u003c\/strong\u003e Silent function plus Sleep Mode for bedrooms and living spaces.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSmart control:\u003c\/strong\u003e Included Smart Kit supports app control through the C\u0026amp;H app.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCleaner operation:\u003c\/strong\u003e Self-cleaning function helps keep the indoor unit hygienic.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eControl options:\u003c\/strong\u003e Remote included; 12V wall thermostat compatible (sold separately).\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cdiv class=\"hvx-kv\" role=\"list\" aria-label=\"At-a-glance\"\u003e\n\u003cdiv role=\"listitem\"\u003e\n\u003cstrong\u003eIndoor\u003c\/strong\u003eCH-RLS12MIA-115VI\u003c\/div\u003e\n\u003cdiv role=\"listitem\"\u003e\n\u003cstrong\u003eOutdoor\u003c\/strong\u003eCH-RLS12MIA-115VO\u003c\/div\u003e\n\u003cdiv role=\"listitem\"\u003e\n\u003cstrong\u003eLines\u003c\/strong\u003e1\/4\" liquid · 3\/8\" gas\u003c\/div\u003e\n\u003cdiv role=\"listitem\"\u003e\n\u003cstrong\u003eMax run\u003c\/strong\u003e82 ft\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"hvx-desc-card\"\u003e\n\u003ch2 class=\"hvx-section-title\"\u003eWhat’s Included\u003c\/h2\u003e\n\u003cul style=\"padding-left: 18px; margin: 8px 0;\"\u003e\n\u003cli\u003eIndoor unit: CH-RLS12MIA-115VI (MIA wall mount, matte finish)\u003c\/li\u003e\n\u003cli\u003eOutdoor unit: CH-RLS12MIA-115VO\u003c\/li\u003e\n\u003cli\u003eRemote control (included)\u003c\/li\u003e\n\u003cli\u003eSmart Kit for app control\u003c\/li\u003e\n\u003cli\u003eLine set, 16 ft communication cable, and drain line\u003c\/li\u003e\n\u003cli\u003eManufacturer documentation (see Documents \u0026amp; Downloads)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"hvx-desc-card\"\u003e\n\u003ch2 class=\"hvx-section-title\"\u003eIndoor Specs\u003c\/h2\u003e\n\u003cdiv class=\"hvx-table-wrap\"\u003e\n\u003ctable class=\"hvx-table\" aria-label=\"Indoor unit specifications\"\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eSpec\u003c\/th\u003e\n\u003cth\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCH-RLS12MIA-115VI\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSystem type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSingle Zone\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRefrigerant type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eR454B\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBTU rated\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e12,000\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower source\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e115V, 1Ph, 60Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eVoltage range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e103.5–126.5 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSEER2\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e21.2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEER2\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e10.1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDehumidification\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2.96 pnt\/day\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRefrigerant piping (liq\/gas)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1\/4\" \/ 3\/8\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMinimum circuit ampacity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMax fuse\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e15\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIndoor noise level (H\/M\/L)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e40.5 \/ 32.5 \/ 25\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIndoor air flow\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e341.4 \/ 309 \/ 206 \/ 176.6\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eUnit dimensions (W×H×D)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e31.57 × 7.44 × 11.69\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePacking dimensions (W×D×H)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e34.45 × 11.22 × 14.96\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNet \/ Gross weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e19.40 \/ 25.13\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating range (Cooling)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e60–90\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating range (Heating)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e32–86\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDrainage water pipe diameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e5\/8\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eESP range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\/\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFilter dimensions (W×D)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\/\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eController\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eRemote controller\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"hvx-desc-card\"\u003e\n\u003ch2 class=\"hvx-section-title\"\u003eOutdoor Specs\u003c\/h2\u003e\n\u003cdiv class=\"hvx-table-wrap\"\u003e\n\u003ctable class=\"hvx-table\" aria-label=\"Outdoor unit specifications\"\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eSpec\u003c\/th\u003e\n\u003cth\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCH-RLS12MIA-115VO\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRefrigerant type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eR454B\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBTU rated\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e12,000\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower source\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e115V, 1Ph, 60Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eVoltage range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e103.5–126.5 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRefrigerant piping (liq\/gas)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1\/4\" \/ 3\/8\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMax pipe length\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e82 ft\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMax height difference (IDU↔ODU)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e49.2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCooling capacity (Min\/Max)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e12,000 (2,200~12,300)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eHeating capacity (Min\/Max)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e12,000 (3,400~12,200)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eHSPF2-5\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e6.7\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eHSPF2-4\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e8.7\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCOP\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3.3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDehumidification\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2.96 pnt\/day\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOutdoor noise level\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e54\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOutdoor air flow\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1,235.3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMinimum circuit ampacity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e19\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMax fuse\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAmbient temp (Cooling)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e5~122\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAmbient temp (Heating)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e5~75\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eUnit dimensions (W×H×D)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e30.12 × 11.93 × 21.85\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNet \/ Gross weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e61.29 \/ 67.02\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePacking dimensions (W×D×H)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e34.84 × 14.76 × 23.82\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRefrigerant precharge\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e25\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAdditional charge (1\/4\" liquid)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.16\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAdditional charge (3\/8\" liquid)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\/\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"hvx-desc-card\"\u003e\n\u003ch2 class=\"hvx-section-title\"\u003eDocuments \u0026amp; Downloads\u003c\/h2\u003e\n\u003cul style=\"padding-left: 18px; margin: 8px 0;\"\u003e\n\u003cli\u003e\u003ca class=\"hvx-link\" href=\"https:\/\/media.cooperandhunter.us\/4717\/CH-RLS12MIA-115VO_CH-RLS12MIA-115VI.pdf\" rel=\"noopener\" target=\"_blank\"\u003eSubmittal (PDF) — CH-RLS12MIA-115VO + CH-RLS12MIA-115VI\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca class=\"hvx-link\" href=\"https:\/\/media.cooperandhunter.us\/4722\/User_manual-MIA%28R454B%29.pdf\" rel=\"noopener\" target=\"_blank\"\u003eUser Manual (PDF) — MIA (R454B)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca class=\"hvx-link\" href=\"https:\/\/media.cooperandhunter.us\/4721\/Remote-controller-manual.pdf\" rel=\"noopener\" target=\"_blank\"\u003eRemote Controller Manual (PDF)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca class=\"hvx-link\" href=\"https:\/\/www.youtube.com\/watch?v=VV3-nC-sKrs\" rel=\"noopener\" target=\"_blank\"\u003eVideo — MIA Series\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca class=\"hvx-link\" href=\"https:\/\/www.ahridirectory.org\/NewSearch?programId=41\u0026amp;searchTypeId=3\u0026amp;productTypeId=4\" rel=\"noopener\" target=\"_blank\"\u003eAHRI Directory — 205756420\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca class=\"hvx-link\" href=\"https:\/\/cooperandhunter.us\/product\/ch-rls12mia-115vi\" rel=\"noopener\" target=\"_blank\"\u003eManufacturer Page — CH-RLS12MIA-115VI\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca class=\"hvx-link\" href=\"https:\/\/cooperandhunter.us\/product\/ch-rls12mia-115vo\" rel=\"noopener\" target=\"_blank\"\u003eManufacturer Page — CH-RLS12MIA-115VO\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"hvx-desc-card\"\u003e\n\u003ch2 class=\"hvx-section-title\"\u003eImportant\u003c\/h2\u003e\n\u003cp style=\"margin: 0; font-size: 14px; color: var(--hvx-slate);\"\u003eProfessional installation is recommended. Confirm electrical requirements, line sizes, maximum line length, and ambient operating limits before installation.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"hvx-desc-card\"\u003e\n\u003ch2 class=\"hvx-section-title\"\u003eFAQs\u003c\/h2\u003e\n\u003cdetails class=\"hvx-faq\" open=\"\"\u003e\n\u003csummary\u003eWhat voltage does this system require?\u003c\/summary\u003e\n\u003cdiv style=\"margin-top: 8px;\"\u003e115V, single phase, 60Hz.\u003c\/div\u003e\n\u003c\/details\u003e\n\u003cdetails class=\"hvx-faq\" open=\"\"\u003e\n\u003csummary\u003eIs this system single-zone or multi-zone?\u003c\/summary\u003e\n\u003cdiv style=\"margin-top: 8px;\"\u003eSingle-zone (one-to-one).\u003c\/div\u003e\n\u003c\/details\u003e\n\u003cdetails class=\"hvx-faq\" open=\"\"\u003e\n\u003csummary\u003eWhat line sizes does this system use?\u003c\/summary\u003e\n\u003cdiv style=\"margin-top: 8px;\"\u003e1\/4\" liquid and 3\/8\" gas.\u003c\/div\u003e\n\u003c\/details\u003e\n\u003cdetails class=\"hvx-faq\" open=\"\"\u003e\n\u003csummary\u003eWhat is the max line length and height difference?\u003c\/summary\u003e\n\u003cdiv style=\"margin-top: 8px;\"\u003eMaximum line length is 82 ft and maximum height difference is 49.2.\u003c\/div\u003e\n\u003c\/details\u003e\n\u003cdetails class=\"hvx-faq\" open=\"\"\u003e\n\u003csummary\u003eWhat are the outdoor ambient operating ranges?\u003c\/summary\u003e\n\u003cdiv style=\"margin-top: 8px;\"\u003eCooling: 5~122. Heating: 5~75.\u003c\/div\u003e\n\u003c\/details\u003e\n\u003cdetails class=\"hvx-faq\" open=\"\"\u003e\n\u003csummary\u003eWhat control options are supported?\u003c\/summary\u003e\n\u003cdiv style=\"margin-top: 8px;\"\u003eSmart Kit app control and remote are supported; a 12V wall thermostat can be purchased separately.\u003c\/div\u003e\n\u003c\/details\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e","brand":"Cooper\u0026Hunter","offers":[{"title":"Default Title","offer_id":42690426667051,"sku":"CH-RLS12MIA-115VI + CH-RLS12MIA-115VO","price":891.36,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0625\/5647\/1339\/files\/24K230V_6edb26d4-f69a-4c32-8a6d-d082397032c7.png?v=1769199376"},{"product_id":"cooper-hunter-9-000-btu-mia-single-zone-wall-mount-minisplit-heat-pump-system-includes-16ft-installation-kit-r454b-230v","title":"Cooper\u0026Hunter 9,000 BTU Mia Single Zone Wall Mount Minisplit Heat Pump System Includes 16FT Installation Kit R454B 230V","description":"\u003cstyle\u003e\n  :root{\n    --hvx-golden:#FAA819;\n    --hvx-slate:#262626;\n    --hvx-ivory:#F4F1E6;\n    --hvx-border:#e2e0d5;\n    --hvx-card-bg:#ffffff;\n  }\n\n  .hvx-desc{\n    font-family:\"Articulat CF\",system-ui,-apple-system,BlinkMacSystemFont,\"Segoe UI\",sans-serif;\n    color:var(--hvx-slate);\n    line-height:1.6;\n    background:var(--hvx-ivory);\n    padding:18px 18px 20px;\n    border-radius:16px;\n  }\n\n  .hvx-desc-header{\n    border-radius:14px;\n    padding:14px 16px;\n    background:linear-gradient(120deg,var(--hvx-golden),var(--hvx-slate));\n    color:#fff;\n    margin:0 0 16px;\n    box-shadow:0 10px 24px rgba(0,0,0,.22);\n    display:flex;\n    align-items:flex-start;\n    gap:12px;\n    flex-wrap:wrap;\n  }\n\n  .hvx-header-text{display:flex;flex-direction:column;gap:6px;min-width:260px}\n  .hvx-eyebrow{\n    font-size:11px;\n    letter-spacing:.14em;\n    text-transform:uppercase;\n    opacity:.9;\n  }\n  .hvx-title{\n    margin:0;\n    font-family:\"Anton\",\"Impact\",system-ui,-apple-system,BlinkMacSystemFont,\"Segoe UI\",sans-serif;\n    font-size:22px;\n    line-height:1.15;\n  }\n  .hvx-subtitle{margin:0;font-size:14px;opacity:.95}\n\n  .hvx-desc-card{\n    border:1px solid var(--hvx-border);\n    border-radius:14px;\n    background:var(--hvx-card-bg);\n    padding:16px 18px 18px;\n    box-shadow:0 4px 12px rgba(0,0,0,.06);\n    margin:14px 0;\n  }\n\n  .hvx-section-title{\n    margin:0 0 10px;\n    font-family:\"Anton\",\"Impact\",system-ui,-apple-system,BlinkMacSystemFont,\"Segoe UI\",sans-serif;\n    font-size:17px;\n    letter-spacing:.08em;\n    text-transform:uppercase;\n    color:var(--hvx-slate);\n    display:inline-flex;\n    align-items:center;\n    gap:8px;\n  }\n  .hvx-section-title::after{\n    content:\"\";\n    flex:1;\n    height:2px;\n    border-radius:999px;\n    background:linear-gradient(90deg,var(--hvx-golden),transparent);\n    opacity:.9;\n  }\n\n  .hvx-cta{display:flex;flex-wrap:wrap;gap:10px;margin:10px 0 0}\n  .hvx-cta a{\n    display:inline-flex;\n    align-items:center;\n    gap:8px;\n    padding:10px 14px;\n    border-radius:12px;\n    border:1px solid var(--hvx-border);\n    background:#fff;\n    text-decoration:none;\n    color:var(--hvx-slate);\n    font-size:14px;\n    font-weight:700;\n  }\n  .hvx-cta a.primary{\n    background:var(--hvx-slate);\n    color:#fff;\n    border-color:transparent;\n  }\n\n  .hvx-badges{display:flex;flex-wrap:wrap;gap:8px;margin:10px 0 0}\n  .hvx-badge{\n    font-size:12px;\n    border:1px solid var(--hvx-border);\n    border-radius:999px;\n    padding:6px 10px;\n    background:#fff;\n    white-space:nowrap;\n  }\n\n  .hvx-kv{\n    display:grid;\n    grid-template-columns:repeat(4,minmax(160px,1fr));\n    gap:10px;\n    margin-top:10px;\n  }\n  .hvx-kv \u003e div{\n    border:1px solid var(--hvx-border);\n    background:#fff;\n    border-radius:12px;\n    padding:10px 12px;\n    text-align:center;\n  }\n  .hvx-kv strong{display:block}\n\n  .hvx-table{\n    width:100%;\n    border-collapse:collapse;\n    min-width:520px;\n    background:#fff;\n    border:1px solid var(--hvx-border);\n    border-radius:12px;\n    overflow:hidden;\n  }\n  .hvx-table th,.hvx-table td{\n    border-bottom:1px solid var(--hvx-border);\n    padding:10px 12px;\n    vertical-align:top;\n    font-size:14px;\n  }\n  .hvx-table th{ text-align:left; font-weight:800; background:#fff; }\n  .hvx-table tr:nth-child(even) td{ background:#fbfaf6; }\n  .hvx-table tr:last-child td{ border-bottom:none; }\n  .hvx-table-wrap{ overflow:auto; border-radius:12px; }\n\n  .hvx-link{color:var(--hvx-slate); text-decoration:underline; text-underline-offset:2px}\n  .hvx-link:hover{opacity:.85}\n\n  details.hvx-faq{\n    border:1px solid var(--hvx-border);\n    background:#fff;\n    border-radius:12px;\n    padding:10px 12px;\n    margin:8px 0;\n  }\n  details.hvx-faq summary{cursor:pointer;font-weight:800}\n\n  @media(max-width:980px){\n    .hvx-kv{grid-template-columns:repeat(2,minmax(160px,1fr))}\n  }\n  @media(max-width:768px){\n    .hvx-desc{padding:14px 12px 16px;border-radius:12px}\n    .hvx-desc-header{padding:12px;border-radius:12px}\n    .hvx-title{font-size:19px}\n    .hvx-desc-card{padding:14px;margin:10px 0}\n  }\n\u003c\/style\u003e\n\u003cdiv class=\"hvx-desc\"\u003e\n\u003cdiv class=\"hvx-desc-header\"\u003e\n\u003cdiv class=\"hvx-header-text\"\u003e\n\u003cdiv class=\"hvx-eyebrow\"\u003eCooper\u0026amp;Hunter MIA • Matte • R454B • 230V\u003c\/div\u003e\n\u003ch1 class=\"hvx-title\"\u003eCooper\u0026amp;Hunter 9,000 BTU MIA Single Zone Wall Mount Mini Split Heat Pump System R454B 230V\u003c\/h1\u003e\n\u003cp class=\"hvx-subtitle\"\u003e\u003cstrong\u003eSKU:\u003c\/strong\u003e CH-RLS09MIA-230VI + CH-RLS09MIA-230VO\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv aria-label=\"Contact options\" class=\"hvx-cta\"\u003e\n\u003ca title=\"Contact Us\" rel=\"noopener\" href=\"https:\/\/hvacsupplies.com\/pages\/contact\" class=\"primary\" target=\"_blank\"\u003e CLICK HERE TO CONTACT US FOR CUSTOM QUOTES AND QUESTIONS \u003c\/a\u003e \u003ca title=\"Call Us Now!\" href=\"tel:+18005438933\"\u003e CLICK TO CALL US 800-543-8933 FOR ANY QUESTIONS \u003c\/a\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"hvx-desc-card\"\u003e\n\u003ch2 class=\"hvx-section-title\"\u003eOverview\u003c\/h2\u003e\n\u003cp style=\"margin: 0;\"\u003eThe Cooper\u0026amp;Hunter \u003cstrong\u003e9K BTU 230V MIA\u003c\/strong\u003e wall-mounted mini split is a one-to-one, \u003cstrong\u003esingle-zone\u003c\/strong\u003e heating and cooling solution designed for smaller rooms and compact spaces. It uses the new \u003cstrong\u003eR454B refrigerant\u003c\/strong\u003e and a sleek \u003cstrong\u003ematte-finish\u003c\/strong\u003e indoor unit that adds a clean, modern look.\u003c\/p\u003e\n\u003cp style=\"margin: 10px 0 0;\"\u003eComfort features include \u003cstrong\u003einverter technology\u003c\/strong\u003e for efficient performance, \u003cstrong\u003eTurbo\u003c\/strong\u003e for quick temperature changes, \u003cstrong\u003eSilent\u003c\/strong\u003e function, \u003cstrong\u003eLED display\u003c\/strong\u003e, \u003cstrong\u003eAuto Swing\u003c\/strong\u003e horizontal louvers for even air distribution, \u003cstrong\u003eSleep Mode\u003c\/strong\u003e, \u003cstrong\u003emultiple fan speeds\u003c\/strong\u003e, \u003cstrong\u003eSelf-Cleaning\u003c\/strong\u003e, and \u003cstrong\u003eFollow Me\u003c\/strong\u003e sensing from the remote. MIA series coils are protected by \u003cstrong\u003eGoldFin\u003c\/strong\u003e anti-corrosive coating, and the included \u003cstrong\u003eSmart Kit\u003c\/strong\u003e supports app control through the C\u0026amp;H app. TU1 copper tubing helps support durability and heat transfer. The package includes a \u003cstrong\u003eline set\u003c\/strong\u003e, \u003cstrong\u003e16 ft communication cable\u003c\/strong\u003e, and \u003cstrong\u003edrain line\u003c\/strong\u003e for easier installation.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"hvx-desc-card\"\u003e\n\u003ch2 class=\"hvx-section-title\"\u003eHighlights\u003c\/h2\u003e\n\u003cdiv role=\"list\" class=\"hvx-badges\"\u003e\n\u003cspan role=\"listitem\" class=\"hvx-badge\"\u003e9,000 BTU class\u003c\/span\u003e \u003cspan role=\"listitem\" class=\"hvx-badge\"\u003e208–230V system\u003c\/span\u003e \u003cspan role=\"listitem\" class=\"hvx-badge\"\u003eSingle-zone (one-to-one)\u003c\/span\u003e \u003cspan role=\"listitem\" class=\"hvx-badge\"\u003eR454B refrigerant\u003c\/span\u003e \u003cspan role=\"listitem\" class=\"hvx-badge\"\u003eSEER2 21.2\u003c\/span\u003e \u003cspan role=\"listitem\" class=\"hvx-badge\"\u003eEER2 12.6\u003c\/span\u003e \u003cspan role=\"listitem\" class=\"hvx-badge\"\u003eInverter technology\u003c\/span\u003e \u003cspan role=\"listitem\" class=\"hvx-badge\"\u003eSmart Kit included\u003c\/span\u003e \u003cspan role=\"listitem\" class=\"hvx-badge\"\u003eGoldFin coil protection\u003c\/span\u003e \u003cspan role=\"listitem\" class=\"hvx-badge\"\u003eAuto Swing (horizontal)\u003c\/span\u003e\n\u003c\/div\u003e\n\u003cul style=\"margin: 12px 0 0; padding-left: 18px;\"\u003e\n\u003cli\u003e\n\u003cstrong\u003eEfficient comfort:\u003c\/strong\u003e Inverter-driven operation helps maintain steady temperatures while reducing energy use.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFast adjustments:\u003c\/strong\u003e Turbo mode for quick heating and cooling changes.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQuiet living:\u003c\/strong\u003e Silent function plus Sleep Mode for bedrooms and living spaces.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSmart control:\u003c\/strong\u003e Included Smart Kit supports app control through the C\u0026amp;H app.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCleaner operation:\u003c\/strong\u003e Self-cleaning function helps keep the indoor unit hygienic.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eControl options:\u003c\/strong\u003e Remote included; wall thermostat compatible (sold separately).\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cdiv aria-label=\"At-a-glance\" role=\"list\" class=\"hvx-kv\"\u003e\n\u003cdiv role=\"listitem\"\u003e\n\u003cstrong\u003eIndoor\u003c\/strong\u003eCH-RLS09MIA-230VI\u003c\/div\u003e\n\u003cdiv role=\"listitem\"\u003e\n\u003cstrong\u003eOutdoor\u003c\/strong\u003eCH-RLS09MIA-230VO\u003c\/div\u003e\n\u003cdiv role=\"listitem\"\u003e\n\u003cstrong\u003eLines\u003c\/strong\u003e1\/4\" liquid · 3\/8\" gas\u003c\/div\u003e\n\u003cdiv role=\"listitem\"\u003e\n\u003cstrong\u003eMax run\u003c\/strong\u003e82 ft\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"hvx-desc-card\"\u003e\n\u003ch2 class=\"hvx-section-title\"\u003eWhat’s Included\u003c\/h2\u003e\n\u003cul style=\"padding-left: 18px; margin: 8px 0;\"\u003e\n\u003cli\u003eIndoor unit: CH-RLS09MIA-230VI (MIA wall mount, matte finish)\u003c\/li\u003e\n\u003cli\u003eOutdoor unit: CH-RLS09MIA-230VO\u003c\/li\u003e\n\u003cli\u003eRemote control (included)\u003c\/li\u003e\n\u003cli\u003eSmart Kit for app control\u003c\/li\u003e\n\u003cli\u003eLine set, 16 ft communication cable, and drain line\u003c\/li\u003e\n\u003cli\u003eManufacturer documentation (see Documents \u0026amp; Downloads)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"hvx-desc-card\"\u003e\n\u003ch2 class=\"hvx-section-title\"\u003eIndoor Specs\u003c\/h2\u003e\n\u003cdiv class=\"hvx-table-wrap\"\u003e\n\u003ctable aria-label=\"Indoor unit specifications\" class=\"hvx-table\"\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eSpec\u003c\/th\u003e\n\u003cth\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCH-RLS09MIA-230VI\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSystem type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSingle Zone\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRefrigerant type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eR454B\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBTU rated\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e9,000\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower source\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e208–230V, 1Ph, 60Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eVoltage range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e187–253 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSEER2\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e21.2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEER2\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e12.6\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDehumidification\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1.90 pnt\/day\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRefrigerant piping (liq\/gas)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1\/4\" \/ 3\/8\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMinimum circuit ampacity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMax fuse\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e15\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIndoor noise level (H\/M\/L)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e35.5 \/ 31.5 \/ 23\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIndoor air flow\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e312 \/ 264.9 \/ 194.2 \/ 153\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eUnit dimensions (W×H×D)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e28.43 × 7.36 × 11.42\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePacking dimensions (W×D×H)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e31.10 × 10.63 × 14.76\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNet \/ Gross weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e16.98 \/ 22.27\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating range (Cooling)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e60–90\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating range (Heating)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e32–86\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDrainage water pipe diameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e5\/8\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eESP range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\/\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFilter dimensions (W×D)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\/\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eController\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eRemote controller\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"hvx-desc-card\"\u003e\n\u003ch2 class=\"hvx-section-title\"\u003eOutdoor Specs\u003c\/h2\u003e\n\u003cdiv class=\"hvx-table-wrap\"\u003e\n\u003ctable aria-label=\"Outdoor unit specifications\" class=\"hvx-table\"\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eSpec\u003c\/th\u003e\n\u003cth\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCH-RLS09MIA-230VO\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRefrigerant type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eR454B\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBTU rated\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e9,000\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower source\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e208–230V, 1Ph, 60Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eVoltage range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e187–253 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRefrigerant piping (liq\/gas)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1\/4\" \/ 3\/8\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMax pipe length\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e82 ft\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMax height difference (IDU↔ODU)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e49.2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCooling capacity (Min\/Max)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e9,000 (2,300~9,700)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eHeating capacity (Min\/Max)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e10,000 (4,300~11,100)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eHSPF2-5\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e7\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eHSPF2-4\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e9.1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCOP\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3.2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDehumidification\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1.90 pnt\/day\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOutdoor noise level\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e53.5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOutdoor air flow\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1,294\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMinimum circuit ampacity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e12\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMax fuse\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e15\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAmbient temp (Cooling)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e5~122\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAmbient temp (Heating)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e5~75\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eUnit dimensions (W×H×D)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e30.12 × 11.93 × 21.85\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNet \/ Gross weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e54.23 \/ 59.74\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePacking dimensions (W×D×H)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e34.84 × 14.76 × 23.82\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRefrigerant precharge\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e25\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAdditional charge (1\/4\" liquid)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.16\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAdditional charge (3\/8\" liquid)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\/\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"hvx-desc-card\"\u003e\n\u003ch2 class=\"hvx-section-title\"\u003eDocuments \u0026amp; Downloads\u003c\/h2\u003e\n\u003cul style=\"padding-left: 18px; margin: 8px 0;\"\u003e\n\u003cli\u003e\u003ca rel=\"noopener\" href=\"https:\/\/media.cooperandhunter.us\/4716\/CH-RLS09MIA-230VO_CH-RLS09MIA-230VI.pdf\" class=\"hvx-link\" target=\"_blank\"\u003eSubmittal (PDF) — CH-RLS09MIA-230VO + CH-RLS09MIA-230VI\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca rel=\"noopener\" href=\"https:\/\/media.cooperandhunter.us\/4722\/User_manual-MIA%28R454B%29.pdf\" class=\"hvx-link\" target=\"_blank\"\u003eUser Manual (PDF) — MIA (R454B)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca rel=\"noopener\" href=\"https:\/\/media.cooperandhunter.us\/4721\/Remote-controller-manual.pdf\" class=\"hvx-link\" target=\"_blank\"\u003eRemote Controller Manual (PDF)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca rel=\"noopener\" href=\"https:\/\/www.youtube.com\/watch?v=VV3-nC-sKrs\" class=\"hvx-link\" target=\"_blank\"\u003eVideo — MIA Series\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca rel=\"noopener\" href=\"https:\/\/www.ahridirectory.org\/NewSearch?programId=41\u0026amp;searchTypeId=3\u0026amp;productTypeId=4\" class=\"hvx-link\" target=\"_blank\"\u003eAHRI Directory — 205756423\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca rel=\"noopener\" href=\"https:\/\/cooperandhunter.us\/product\/ch-rls09mia-230vi\" class=\"hvx-link\" target=\"_blank\"\u003eManufacturer Page — CH-RLS09MIA-230VI\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca rel=\"noopener\" href=\"https:\/\/cooperandhunter.us\/product\/ch-rls09mia-230vo\" class=\"hvx-link\" target=\"_blank\"\u003eManufacturer Page — CH-RLS09MIA-230VO\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"hvx-desc-card\"\u003e\n\u003ch2 class=\"hvx-section-title\"\u003eImportant\u003c\/h2\u003e\n\u003cp style=\"margin: 0; font-size: 14px; color: var(--hvx-slate);\"\u003eProfessional installation is recommended. Confirm electrical requirements, line sizes, maximum line length, and ambient operating limits before installation.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"hvx-desc-card\"\u003e\n\u003ch2 class=\"hvx-section-title\"\u003eFAQs\u003c\/h2\u003e\n\u003cdetails open=\"\" class=\"hvx-faq\"\u003e\n\u003csummary\u003eWhat voltage does this system require?\u003c\/summary\u003e\n\u003cdiv style=\"margin-top: 8px;\"\u003e208–230V, single phase, 60Hz.\u003c\/div\u003e\n\u003c\/details\u003e\n\u003cdetails open=\"\" class=\"hvx-faq\"\u003e\n\u003csummary\u003eIs this system single-zone or multi-zone?\u003c\/summary\u003e\n\u003cdiv style=\"margin-top: 8px;\"\u003eSingle-zone (one-to-one).\u003c\/div\u003e\n\u003c\/details\u003e\n\u003cdetails open=\"\" class=\"hvx-faq\"\u003e\n\u003csummary\u003eWhat line sizes does this system use?\u003c\/summary\u003e\n\u003cdiv style=\"margin-top: 8px;\"\u003e1\/4\" liquid and 3\/8\" gas.\u003c\/div\u003e\n\u003c\/details\u003e\n\u003cdetails open=\"\" class=\"hvx-faq\"\u003e\n\u003csummary\u003eWhat is the max line length and height difference?\u003c\/summary\u003e\n\u003cdiv style=\"margin-top: 8px;\"\u003eMaximum line length is 82 ft and maximum height difference is 49.2.\u003c\/div\u003e\n\u003c\/details\u003e\n\u003cdetails open=\"\" class=\"hvx-faq\"\u003e\n\u003csummary\u003eWhat are the outdoor ambient operating ranges?\u003c\/summary\u003e\n\u003cdiv style=\"margin-top: 8px;\"\u003eCooling: 5~122. Heating: 5~75.\u003c\/div\u003e\n\u003c\/details\u003e\n\u003cdetails open=\"\" class=\"hvx-faq\"\u003e\n\u003csummary\u003eWhat control options are supported?\u003c\/summary\u003e\n\u003cdiv style=\"margin-top: 8px;\"\u003eSmart Kit app control and remote are supported; a wall thermostat can be purchased separately.\u003c\/div\u003e\n\u003c\/details\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e","brand":"Cooper\u0026Hunter","offers":[{"title":"Default Title","offer_id":42690497282091,"sku":"CH-RLS09MIA-230VI + CH-RLS09MIA-230VO","price":830.88,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0625\/5647\/1339\/files\/24K230V_6edb26d4-f69a-4c32-8a6d-d082397032c7.png?v=1769199376"},{"product_id":"cooper-hunter-12-000-btu-mia-single-zone-wall-mount-minisplit-heat-pump-system-includes-16ft-installation-kit-r454b-230v","title":"Cooper\u0026Hunter 12,000 BTU Mia Single Zone Wall Mount Minisplit Heat Pump System Includes 16FT Installation Kit R454B 230V","description":"\u003cstyle\u003e\n  :root{\n    --hvx-golden:#FAA819;\n    --hvx-slate:#262626;\n    --hvx-ivory:#F4F1E6;\n    --hvx-border:#e2e0d5;\n    --hvx-card-bg:#ffffff;\n  }\n\n  .hvx-desc{\n    font-family:\"Articulat CF\",system-ui,-apple-system,BlinkMacSystemFont,\"Segoe UI\",sans-serif;\n    color:var(--hvx-slate);\n    line-height:1.6;\n    background:var(--hvx-ivory);\n    padding:18px 18px 20px;\n    border-radius:16px;\n  }\n\n  .hvx-desc-header{\n    border-radius:14px;\n    padding:14px 16px;\n    background:linear-gradient(120deg,var(--hvx-golden),var(--hvx-slate));\n    color:#fff;\n    margin:0 0 16px;\n    box-shadow:0 10px 24px rgba(0,0,0,.22);\n    display:flex;\n    align-items:flex-start;\n    gap:12px;\n    flex-wrap:wrap;\n  }\n\n  .hvx-header-text{display:flex;flex-direction:column;gap:6px;min-width:260px}\n  .hvx-eyebrow{\n    font-size:11px;\n    letter-spacing:.14em;\n    text-transform:uppercase;\n    opacity:.9;\n  }\n  .hvx-title{\n    margin:0;\n    font-family:\"Anton\",\"Impact\",system-ui,-apple-system,BlinkMacSystemFont,\"Segoe UI\",sans-serif;\n    font-size:22px;\n    line-height:1.15;\n  }\n  .hvx-subtitle{margin:0;font-size:14px;opacity:.95}\n\n  .hvx-desc-card{\n    border:1px solid var(--hvx-border);\n    border-radius:14px;\n    background:var(--hvx-card-bg);\n    padding:16px 18px 18px;\n    box-shadow:0 4px 12px rgba(0,0,0,.06);\n    margin:14px 0;\n  }\n\n  .hvx-section-title{\n    margin:0 0 10px;\n    font-family:\"Anton\",\"Impact\",system-ui,-apple-system,BlinkMacSystemFont,\"Segoe UI\",sans-serif;\n    font-size:17px;\n    letter-spacing:.08em;\n    text-transform:uppercase;\n    color:var(--hvx-slate);\n    display:inline-flex;\n    align-items:center;\n    gap:8px;\n  }\n  .hvx-section-title::after{\n    content:\"\";\n    flex:1;\n    height:2px;\n    border-radius:999px;\n    background:linear-gradient(90deg,var(--hvx-golden),transparent);\n    opacity:.9;\n  }\n\n  .hvx-cta{display:flex;flex-wrap:wrap;gap:10px;margin:10px 0 0}\n  .hvx-cta a{\n    display:inline-flex;\n    align-items:center;\n    gap:8px;\n    padding:10px 14px;\n    border-radius:12px;\n    border:1px solid var(--hvx-border);\n    background:#fff;\n    text-decoration:none;\n    color:var(--hvx-slate);\n    font-size:14px;\n    font-weight:700;\n  }\n  .hvx-cta a.primary{\n    background:var(--hvx-slate);\n    color:#fff;\n    border-color:transparent;\n  }\n\n  .hvx-badges{display:flex;flex-wrap:wrap;gap:8px;margin:10px 0 0}\n  .hvx-badge{\n    font-size:12px;\n    border:1px solid var(--hvx-border);\n    border-radius:999px;\n    padding:6px 10px;\n    background:#fff;\n    white-space:nowrap;\n  }\n\n  .hvx-kv{\n    display:grid;\n    grid-template-columns:repeat(4,minmax(160px,1fr));\n    gap:10px;\n    margin-top:10px;\n  }\n  .hvx-kv \u003e div{\n    border:1px solid var(--hvx-border);\n    background:#fff;\n    border-radius:12px;\n    padding:10px 12px;\n    text-align:center;\n  }\n  .hvx-kv strong{display:block}\n\n  .hvx-table{\n    width:100%;\n    border-collapse:collapse;\n    min-width:520px;\n    background:#fff;\n    border:1px solid var(--hvx-border);\n    border-radius:12px;\n    overflow:hidden;\n  }\n  .hvx-table th,.hvx-table td{\n    border-bottom:1px solid var(--hvx-border);\n    padding:10px 12px;\n    vertical-align:top;\n    font-size:14px;\n  }\n  .hvx-table th{ text-align:left; font-weight:800; background:#fff; }\n  .hvx-table tr:nth-child(even) td{ background:#fbfaf6; }\n  .hvx-table tr:last-child td{ border-bottom:none; }\n  .hvx-table-wrap{ overflow:auto; border-radius:12px; }\n\n  .hvx-link{color:var(--hvx-slate); text-decoration:underline; text-underline-offset:2px}\n  .hvx-link:hover{opacity:.85}\n\n  details.hvx-faq{\n    border:1px solid var(--hvx-border);\n    background:#fff;\n    border-radius:12px;\n    padding:10px 12px;\n    margin:8px 0;\n  }\n  details.hvx-faq summary{cursor:pointer;font-weight:800}\n\n  @media(max-width:980px){\n    .hvx-kv{grid-template-columns:repeat(2,minmax(160px,1fr))}\n  }\n  @media(max-width:768px){\n    .hvx-desc{padding:14px 12px 16px;border-radius:12px}\n    .hvx-desc-header{padding:12px;border-radius:12px}\n    .hvx-title{font-size:19px}\n    .hvx-desc-card{padding:14px;margin:10px 0}\n  }\n\u003c\/style\u003e\n\u003cdiv class=\"hvx-desc\"\u003e\n\u003cdiv class=\"hvx-desc-header\"\u003e\n\u003cdiv class=\"hvx-header-text\"\u003e\n\u003cdiv class=\"hvx-eyebrow\"\u003eCooper\u0026amp;Hunter MIA • Matte • R454B • 230V\u003c\/div\u003e\n\u003ch1 class=\"hvx-title\"\u003eCooper\u0026amp;Hunter 12,000 BTU MIA Single Zone Wall Mount Mini Split Heat Pump System R454B 230V\u003c\/h1\u003e\n\u003cp class=\"hvx-subtitle\"\u003e\u003cstrong\u003eSKU:\u003c\/strong\u003e CH-RLS12MIA-230VI + CH-RLS12MIA-230VO\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"hvx-cta\" aria-label=\"Contact options\"\u003e\n\u003ca class=\"primary\" href=\"https:\/\/hvacsupplies.com\/pages\/contact\" rel=\"noopener\" title=\"Contact Us\" target=\"_blank\"\u003e CLICK HERE TO CONTACT US FOR CUSTOM QUOTES AND QUESTIONS \u003c\/a\u003e \u003ca href=\"tel:+18005438933\" title=\"Call Us Now!\"\u003e CLICK TO CALL US 800-543-8933 FOR ANY QUESTIONS \u003c\/a\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"hvx-desc-card\"\u003e\n\u003ch2 class=\"hvx-section-title\"\u003eOverview\u003c\/h2\u003e\n\u003cp style=\"margin: 0;\"\u003eThe Cooper\u0026amp;Hunter \u003cstrong\u003e12K BTU MIA\u003c\/strong\u003e wall-mounted mini split system is a one-to-one, \u003cstrong\u003esingle-zone\u003c\/strong\u003e solution built for efficient comfort in smaller rooms. It features \u003cstrong\u003eR454B refrigerant\u003c\/strong\u003e, a sleek \u003cstrong\u003ematte-finish\u003c\/strong\u003e indoor unit, and inverter-driven performance with up to \u003cstrong\u003e21.3 SEER2\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp style=\"margin: 10px 0 0;\"\u003eComfort features include \u003cstrong\u003eTurbo Mode\u003c\/strong\u003e for quick temperature changes, \u003cstrong\u003eAuto Swing\u003c\/strong\u003e horizontal louvers for even airflow, \u003cstrong\u003eSilent\u003c\/strong\u003e operation modes, \u003cstrong\u003eSleep Mode\u003c\/strong\u003e, multiple fan speeds, \u003cstrong\u003eSelf-Clean\u003c\/strong\u003e, and \u003cstrong\u003eFollow Me\u003c\/strong\u003e temperature sensing from the remote. Connectivity is supported via the included \u003cstrong\u003eSmart Kit\u003c\/strong\u003e and the downloadable C\u0026amp;H app.\u003c\/p\u003e\n\u003cp style=\"margin: 10px 0 0;\"\u003eMIA series coils are protected by \u003cstrong\u003eGoldFin\u003c\/strong\u003e anti-corrosive coating, and the indoor unit uses \u003cstrong\u003eTU1 copper tubing\u003c\/strong\u003e for durability and efficient heat transfer.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"hvx-desc-card\"\u003e\n\u003ch2 class=\"hvx-section-title\"\u003eHighlights\u003c\/h2\u003e\n\u003cdiv class=\"hvx-badges\" role=\"list\"\u003e\n\u003cspan class=\"hvx-badge\" role=\"listitem\"\u003e12,000 BTU class\u003c\/span\u003e \u003cspan class=\"hvx-badge\" role=\"listitem\"\u003eR454B refrigerant\u003c\/span\u003e \u003cspan class=\"hvx-badge\" role=\"listitem\"\u003eSEER2 21.3\u003c\/span\u003e \u003cspan class=\"hvx-badge\" role=\"listitem\"\u003eEER2 10.8\u003c\/span\u003e \u003cspan class=\"hvx-badge\" role=\"listitem\"\u003eInverter technology\u003c\/span\u003e \u003cspan class=\"hvx-badge\" role=\"listitem\"\u003eSmart Kit included\u003c\/span\u003e \u003cspan class=\"hvx-badge\" role=\"listitem\"\u003eAuto Swing (horizontal)\u003c\/span\u003e \u003cspan class=\"hvx-badge\" role=\"listitem\"\u003eMatte wall mount\u003c\/span\u003e \u003cspan class=\"hvx-badge\" role=\"listitem\"\u003e208–230V, 1Ph, 60Hz\u003c\/span\u003e\n\u003c\/div\u003e\n\u003cul style=\"margin: 12px 0 0; padding-left: 18px;\"\u003e\n\u003cli\u003e\n\u003cstrong\u003eEfficient comfort:\u003c\/strong\u003e inverter-driven operation matches demand for steady temperatures and lower energy use.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFast response:\u003c\/strong\u003e Turbo Mode delivers quick cooling or heating when needed.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEven airflow:\u003c\/strong\u003e Auto Swing helps reduce hot and cold spots.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSmart control:\u003c\/strong\u003e included Smart Kit supports app control; remote is included.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDurability:\u003c\/strong\u003e GoldFin coil protection and TU1 copper tubing.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cdiv class=\"hvx-kv\" role=\"list\" aria-label=\"At-a-glance\"\u003e\n\u003cdiv role=\"listitem\"\u003e\n\u003cstrong\u003eIndoor\u003c\/strong\u003eCH-RLS12MIA-230VI\u003c\/div\u003e\n\u003cdiv role=\"listitem\"\u003e\n\u003cstrong\u003eOutdoor\u003c\/strong\u003eCH-RLS12MIA-230VO\u003c\/div\u003e\n\u003cdiv role=\"listitem\"\u003e\n\u003cstrong\u003eLines\u003c\/strong\u003e1\/4\" liquid · 3\/8\" gas\u003c\/div\u003e\n\u003cdiv role=\"listitem\"\u003e\n\u003cstrong\u003eMax run\u003c\/strong\u003e82 ft\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"hvx-desc-card\"\u003e\n\u003ch2 class=\"hvx-section-title\"\u003eWhat’s Included\u003c\/h2\u003e\n\u003cul style=\"padding-left: 18px; margin: 8px 0;\"\u003e\n\u003cli\u003eIndoor unit: CH-RLS12MIA-230VI\u003c\/li\u003e\n\u003cli\u003eOutdoor unit: CH-RLS12MIA-230VO\u003c\/li\u003e\n\u003cli\u003eRemote control (included)\u003c\/li\u003e\n\u003cli\u003eSmart Kit for app control\u003c\/li\u003e\n\u003cli\u003eLine set, communication cable (16 ft.), and drain line\u003c\/li\u003e\n\u003cli\u003eManufacturer documentation (see Documents \u0026amp; Downloads)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"hvx-desc-card\"\u003e\n\u003ch2 class=\"hvx-section-title\"\u003eIndoor Specs\u003c\/h2\u003e\n\u003cdiv class=\"hvx-table-wrap\"\u003e\n\u003ctable class=\"hvx-table\" aria-label=\"Indoor unit specifications\"\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eSpec\u003c\/th\u003e\n\u003cth\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCH-RLS12MIA-230VI\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSystem type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSingle Zone\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRefrigerant type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eR454B\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated capacity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e12,000 BTU\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower source\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e208–230V, 1Ph, 60Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eVoltage range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e187–253 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDehumidification\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3.17 pnt\/day\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSEER2\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e21.3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEER2\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e10.8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMinimum circuit ampacity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMax fuse\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e15\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRefrigerant piping (liq\/gas)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1\/4\" \/ 3\/8\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIndoor air flow\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e359 \/ 306.1 \/ 206 \/ 144.2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIndoor noise level (H\/M\/L)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e38 \/ 32 \/ 22.5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eUnit dimensions (W×H×D)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e31.57 × 7.44 × 11.69\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePacking dimensions (W×D×H)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e34.45 × 11.22 × 14.96\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNet \/ Gross weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e19.40 \/ 25.13\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating range (Cooling)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e60–90\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating range (Heating)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e32–86\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDrainage water pipe diameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e5\/8\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"hvx-desc-card\"\u003e\n\u003ch2 class=\"hvx-section-title\"\u003eOutdoor Specs\u003c\/h2\u003e\n\u003cdiv class=\"hvx-table-wrap\"\u003e\n\u003ctable class=\"hvx-table\" aria-label=\"Outdoor unit specifications\"\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eSpec\u003c\/th\u003e\n\u003cth\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCH-RLS12MIA-230VO\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRefrigerant type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eR454B\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated capacity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e12,000 BTU\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower source\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e208–230V, 1Ph, 60Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eVoltage range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e187–253 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDehumidification\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3.17 pnt\/day\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRefrigerant piping (liq\/gas)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1\/4\" \/ 3\/8\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMax pipe length\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e82 ft\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMax height difference (IDU↔ODU)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e49.2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCooling capacity (Min\/Max)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e12,000 (1,700~13,300)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eHeating capacity (Min\/Max)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e12,000 (3,500~13,400)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eHSPF2-5\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e7\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eHSPF2-4\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e9.1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCOP\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3.18\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOutdoor noise level\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e54\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOutdoor air flow\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1,235.3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMinimum circuit ampacity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e13\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMax fuse\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e15\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAmbient temp (Heating)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e5 ~ 75\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAmbient temp (Cooling)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e5 ~ 122\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eUnit dimensions (W×H×D)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e30.12 × 11.93 × 21.85\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNet \/ Gross weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e59.08 \/ 64.37\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePacking dimensions (W×D×H)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e34.84 × 14.76 × 23.82\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRefrigerant precharge\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e25\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAdditional charge (1\/4\" liquid)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.16\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"hvx-desc-card\"\u003e\n\u003ch2 class=\"hvx-section-title\"\u003eDocuments \u0026amp; Downloads\u003c\/h2\u003e\n\u003cul style=\"padding-left: 18px; margin: 8px 0;\"\u003e\n\u003cli\u003e\u003ca class=\"hvx-link\" href=\"https:\/\/media.cooperandhunter.us\/4718\/CH-RLS12MIA-230VO_CH-RLS12MIA-230VI.pdf\" rel=\"noopener\" target=\"_blank\"\u003eSubmittal (PDF) — CH-RLS12MIA-230VO + CH-RLS12MIA-230VI\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca class=\"hvx-link\" href=\"https:\/\/media.cooperandhunter.us\/4722\/User_manual-MIA%28R454B%29.pdf\" rel=\"noopener\" target=\"_blank\"\u003eUser Manual (PDF) — MIA (R454B)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca class=\"hvx-link\" href=\"https:\/\/media.cooperandhunter.us\/4721\/Remote-controller-manual.pdf\" rel=\"noopener\" target=\"_blank\"\u003eRemote Controller Manual (PDF)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca class=\"hvx-link\" href=\"https:\/\/www.youtube.com\/watch?v=VV3-nC-sKrs\" rel=\"noopener\" target=\"_blank\"\u003eVideo — MIA Series\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003eAHRI Certified: 205756422 (search AHRI directory)\u003c\/li\u003e\n\u003cli\u003eManufacturer pages: CH-RLS12MIA-230VI, CH-RLS12MIA-230VO\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"hvx-desc-card\"\u003e\n\u003ch2 class=\"hvx-section-title\"\u003eImportant\u003c\/h2\u003e\n\u003cp style=\"margin: 0; font-size: 14px; color: var(--hvx-slate);\"\u003eProfessional installation is recommended. Confirm electrical requirements, line sizes, maximum line length, and ambient operating limits before installation.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"hvx-desc-card\"\u003e\n\u003ch2 class=\"hvx-section-title\"\u003eFAQs\u003c\/h2\u003e\n\u003cdetails class=\"hvx-faq\" open=\"\"\u003e\n\u003csummary\u003eWhat voltage does this system require?\u003c\/summary\u003e\n\u003cdiv style=\"margin-top: 8px;\"\u003e208–230V, single phase, 60Hz.\u003c\/div\u003e\n\u003c\/details\u003e\n\u003cdetails class=\"hvx-faq\" open=\"\"\u003e\n\u003csummary\u003eWhat line sizes does this system use?\u003c\/summary\u003e\n\u003cdiv style=\"margin-top: 8px;\"\u003e1\/4\" liquid and 3\/8\" gas.\u003c\/div\u003e\n\u003c\/details\u003e\n\u003cdetails class=\"hvx-faq\" open=\"\"\u003e\n\u003csummary\u003eWhat is the max line length and height difference?\u003c\/summary\u003e\n\u003cdiv style=\"margin-top: 8px;\"\u003eMaximum line length is 82 ft and maximum height difference is 49.2.\u003c\/div\u003e\n\u003c\/details\u003e\n\u003cdetails class=\"hvx-faq\" open=\"\"\u003e\n\u003csummary\u003eWhat are the outdoor ambient operating ranges?\u003c\/summary\u003e\n\u003cdiv style=\"margin-top: 8px;\"\u003eCooling: 5~122. Heating: 5~75.\u003c\/div\u003e\n\u003c\/details\u003e\n\u003cdetails class=\"hvx-faq\" open=\"\"\u003e\n\u003csummary\u003eWhat control options are supported?\u003c\/summary\u003e\n\u003cdiv style=\"margin-top: 8px;\"\u003eSmart Kit app control and remote are supported; a 12V wall thermostat can be purchased separately.\u003c\/div\u003e\n\u003c\/details\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e","brand":"Cooper\u0026Hunter","offers":[{"title":"Default Title","offer_id":42690502819883,"sku":"CH-RLS12MIA-230VI + CH-RLS12MIA-230VO","price":891.36,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0625\/5647\/1339\/files\/24K230V_6edb26d4-f69a-4c32-8a6d-d082397032c7.png?v=1769199376"},{"product_id":"cooper-hunter-18-000-btu-mia-single-zone-wall-mount-minisplit-heat-pump-system-r454b-230v","title":"Cooper\u0026Hunter 18,000 BTU Mia Single Zone Wall Mount Minisplit Heat Pump System R454B 230V","description":"\u003cstyle\u003e\n  :root{\n    --hvx-golden:#FAA819;\n    --hvx-slate:#262626;\n    --hvx-ivory:#F4F1E6;\n    --hvx-border:#e2e0d5;\n    --hvx-card-bg:#ffffff;\n  }\n\n  .hvx-desc{\n    font-family:\"Articulat CF\",system-ui,-apple-system,BlinkMacSystemFont,\"Segoe UI\",sans-serif;\n    color:var(--hvx-slate);\n    line-height:1.6;\n    background:var(--hvx-ivory);\n    padding:18px 18px 20px;\n    border-radius:16px;\n  }\n\n  .hvx-desc-header{\n    border-radius:14px;\n    padding:14px 16px;\n    background:linear-gradient(120deg,var(--hvx-golden),var(--hvx-slate));\n    color:#fff;\n    margin:0 0 16px;\n    box-shadow:0 10px 24px rgba(0,0,0,.22);\n    display:flex;\n    align-items:flex-start;\n    gap:12px;\n    flex-wrap:wrap;\n  }\n\n  .hvx-header-text{display:flex;flex-direction:column;gap:6px;min-width:260px}\n  .hvx-eyebrow{\n    font-size:11px;\n    letter-spacing:.14em;\n    text-transform:uppercase;\n    opacity:.9;\n  }\n  .hvx-title{\n    margin:0;\n    font-family:\"Anton\",\"Impact\",system-ui,-apple-system,BlinkMacSystemFont,\"Segoe UI\",sans-serif;\n    font-size:22px;\n    line-height:1.15;\n  }\n  .hvx-subtitle{margin:0;font-size:14px;opacity:.95}\n\n  .hvx-desc-card{\n    border:1px solid var(--hvx-border);\n    border-radius:14px;\n    background:var(--hvx-card-bg);\n    padding:16px 18px 18px;\n    box-shadow:0 4px 12px rgba(0,0,0,.06);\n    margin:14px 0;\n  }\n\n  .hvx-section-title{\n    margin:0 0 10px;\n    font-family:\"Anton\",\"Impact\",system-ui,-apple-system,BlinkMacSystemFont,\"Segoe UI\",sans-serif;\n    font-size:17px;\n    letter-spacing:.08em;\n    text-transform:uppercase;\n    color:var(--hvx-slate);\n    display:inline-flex;\n    align-items:center;\n    gap:8px;\n  }\n  .hvx-section-title::after{\n    content:\"\";\n    flex:1;\n    height:2px;\n    border-radius:999px;\n    background:linear-gradient(90deg,var(--hvx-golden),transparent);\n    opacity:.9;\n  }\n\n  .hvx-cta{display:flex;flex-wrap:wrap;gap:10px;margin:10px 0 0}\n  .hvx-cta a{\n    display:inline-flex;\n    align-items:center;\n    gap:8px;\n    padding:10px 14px;\n    border-radius:12px;\n    border:1px solid var(--hvx-border);\n    background:#fff;\n    text-decoration:none;\n    color:var(--hvx-slate);\n    font-size:14px;\n    font-weight:700;\n  }\n  .hvx-cta a.primary{\n    background:var(--hvx-slate);\n    color:#fff;\n    border-color:transparent;\n  }\n\n  .hvx-badges{display:flex;flex-wrap:wrap;gap:8px;margin:10px 0 0}\n  .hvx-badge{\n    font-size:12px;\n    border:1px solid var(--hvx-border);\n    border-radius:999px;\n    padding:6px 10px;\n    background:#fff;\n    white-space:nowrap;\n  }\n\n  .hvx-kv{\n    display:grid;\n    grid-template-columns:repeat(4,minmax(160px,1fr));\n    gap:10px;\n    margin-top:10px;\n  }\n  .hvx-kv \u003e div{\n    border:1px solid var(--hvx-border);\n    background:#fff;\n    border-radius:12px;\n    padding:10px 12px;\n    text-align:center;\n  }\n  .hvx-kv strong{display:block}\n\n  .hvx-table{\n    width:100%;\n    border-collapse:collapse;\n    min-width:520px;\n    background:#fff;\n    border:1px solid var(--hvx-border);\n    border-radius:12px;\n    overflow:hidden;\n  }\n  .hvx-table th,.hvx-table td{\n    border-bottom:1px solid var(--hvx-border);\n    padding:10px 12px;\n    vertical-align:top;\n    font-size:14px;\n  }\n  .hvx-table th{ text-align:left; font-weight:800; background:#fff; }\n  .hvx-table tr:nth-child(even) td{ background:#fbfaf6; }\n  .hvx-table tr:last-child td{ border-bottom:none; }\n  .hvx-table-wrap{ overflow:auto; border-radius:12px; }\n\n  .hvx-link{color:var(--hvx-slate); text-decoration:underline; text-underline-offset:2px}\n  .hvx-link:hover{opacity:.85}\n\n  details.hvx-faq{\n    border:1px solid var(--hvx-border);\n    background:#fff;\n    border-radius:12px;\n    padding:10px 12px;\n    margin:8px 0;\n  }\n  details.hvx-faq summary{cursor:pointer;font-weight:800}\n\n  @media(max-width:980px){\n    .hvx-kv{grid-template-columns:repeat(2,minmax(160px,1fr))}\n  }\n  @media(max-width:768px){\n    .hvx-desc{padding:14px 12px 16px;border-radius:12px}\n    .hvx-desc-header{padding:12px;border-radius:12px}\n    .hvx-title{font-size:19px}\n    .hvx-desc-card{padding:14px;margin:10px 0}\n  }\n\u003c\/style\u003e\n\u003cdiv class=\"hvx-desc\"\u003e\n\u003cdiv class=\"hvx-desc-header\"\u003e\n\u003cdiv class=\"hvx-header-text\"\u003e\n\u003cdiv class=\"hvx-eyebrow\"\u003eCooper\u0026amp;Hunter MIA • Matte • R454B • 230V\u003c\/div\u003e\n\u003ch1 class=\"hvx-title\"\u003eCooper\u0026amp;Hunter 18,000 BTU MIA Single Zone Wall Mount Mini Split Heat Pump System R454B 230V\u003c\/h1\u003e\n\u003cp class=\"hvx-subtitle\"\u003e\u003cstrong\u003eSKU:\u003c\/strong\u003e CH-RLS18MIA-230VI + CH-RLS18MIA-230VO\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv aria-label=\"Contact options\" class=\"hvx-cta\"\u003e\n\u003ca title=\"Contact Us\" rel=\"noopener\" href=\"https:\/\/hvacsupplies.com\/pages\/contact\" class=\"primary\" target=\"_blank\"\u003e CLICK HERE TO CONTACT US FOR CUSTOM QUOTES AND QUESTIONS \u003c\/a\u003e \u003ca title=\"Call Us Now!\" href=\"tel:+18005438933\"\u003e CLICK TO CALL US 800-543-8933 FOR ANY QUESTIONS \u003c\/a\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"hvx-desc-card\"\u003e\n\u003ch2 class=\"hvx-section-title\"\u003eOverview\u003c\/h2\u003e\n\u003cp style=\"margin: 0;\"\u003eThe Cooper\u0026amp;Hunter \u003cstrong\u003e18K BTU MIA\u003c\/strong\u003e wall-mounted mini split system is a one-to-one, \u003cstrong\u003esingle-zone\u003c\/strong\u003e solution designed for efficient comfort with a clean \u003cstrong\u003ematte\u003c\/strong\u003e indoor finish. It uses \u003cstrong\u003eR454B refrigerant\u003c\/strong\u003e and inverter-driven operation for steady temperatures and energy savings, with up to \u003cstrong\u003e19.2 SEER2\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp style=\"margin: 10px 0 0;\"\u003eComfort features include \u003cstrong\u003eTurbo Mode\u003c\/strong\u003e, \u003cstrong\u003eAuto Swing\u003c\/strong\u003e horizontal louvers, multiple fan speeds, \u003cstrong\u003eSleep Mode\u003c\/strong\u003e, \u003cstrong\u003eSelf-Clean\u003c\/strong\u003e, and \u003cstrong\u003eFollow Me\u003c\/strong\u003e temperature sensing from the remote. Connectivity is supported via the included \u003cstrong\u003eSmart Kit\u003c\/strong\u003e and the downloadable C\u0026amp;H app.\u003c\/p\u003e\n\u003cp style=\"margin: 10px 0 0;\"\u003eMIA series coils are protected by \u003cstrong\u003eGoldFin\u003c\/strong\u003e anti-corrosive coating, and the indoor unit uses \u003cstrong\u003eTU1 copper tubing\u003c\/strong\u003e for durability and efficient heat transfer.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"hvx-desc-card\"\u003e\n\u003ch2 class=\"hvx-section-title\"\u003eHighlights\u003c\/h2\u003e\n\u003cdiv role=\"list\" class=\"hvx-badges\"\u003e\n\u003cspan role=\"listitem\" class=\"hvx-badge\"\u003e18,000 BTU class\u003c\/span\u003e \u003cspan role=\"listitem\" class=\"hvx-badge\"\u003eR454B refrigerant\u003c\/span\u003e \u003cspan role=\"listitem\" class=\"hvx-badge\"\u003eSEER2 19.2\u003c\/span\u003e \u003cspan role=\"listitem\" class=\"hvx-badge\"\u003eEER2 10.8\u003c\/span\u003e \u003cspan role=\"listitem\" class=\"hvx-badge\"\u003eInverter technology\u003c\/span\u003e \u003cspan role=\"listitem\" class=\"hvx-badge\"\u003eSmart Kit included\u003c\/span\u003e \u003cspan role=\"listitem\" class=\"hvx-badge\"\u003eAuto Swing (horizontal)\u003c\/span\u003e \u003cspan role=\"listitem\" class=\"hvx-badge\"\u003eGoldFin coil protection\u003c\/span\u003e \u003cspan role=\"listitem\" class=\"hvx-badge\"\u003e208–230V, 1Ph, 60Hz\u003c\/span\u003e\n\u003c\/div\u003e\n\u003cul style=\"margin: 12px 0 0; padding-left: 18px;\"\u003e\n\u003cli\u003e\n\u003cstrong\u003eEfficient comfort:\u003c\/strong\u003e inverter-driven operation matches demand for stable temperatures and lower energy use.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFast changes:\u003c\/strong\u003e Turbo Mode for rapid cooling or heating.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEven airflow:\u003c\/strong\u003e Auto Swing helps reduce hot\/cold spots.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSmart control:\u003c\/strong\u003e included Smart Kit supports app control; remote is included.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDurability:\u003c\/strong\u003e GoldFin coil protection and TU1 copper tubing.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cdiv aria-label=\"At-a-glance\" role=\"list\" class=\"hvx-kv\"\u003e\n\u003cdiv role=\"listitem\"\u003e\n\u003cstrong\u003eIndoor\u003c\/strong\u003eCH-RLS18MIA-230VI\u003c\/div\u003e\n\u003cdiv role=\"listitem\"\u003e\n\u003cstrong\u003eOutdoor\u003c\/strong\u003eCH-RLS18MIA-230VO\u003c\/div\u003e\n\u003cdiv role=\"listitem\"\u003e\n\u003cstrong\u003eLines\u003c\/strong\u003e1\/4\" liquid · 1\/2\" gas\u003c\/div\u003e\n\u003cdiv role=\"listitem\"\u003e\n\u003cstrong\u003eMax run\u003c\/strong\u003e98.4 ft\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"hvx-desc-card\"\u003e\n\u003ch2 class=\"hvx-section-title\"\u003eWhat’s Included\u003c\/h2\u003e\n\u003cul style=\"padding-left: 18px; margin: 8px 0;\"\u003e\n\u003cli\u003eIndoor unit: CH-RLS18MIA-230VI\u003c\/li\u003e\n\u003cli\u003eOutdoor unit: CH-RLS18MIA-230VO\u003c\/li\u003e\n\u003cli\u003eRemote control (included)\u003c\/li\u003e\n\u003cli\u003eSmart Kit for app control\u003c\/li\u003e\n\u003cli\u003eLine set, communication cable (16 ft.), and drain line\u003c\/li\u003e\n\u003cli\u003eManufacturer documentation (see Documents \u0026amp; Downloads)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"hvx-desc-card\"\u003e\n\u003ch2 class=\"hvx-section-title\"\u003eIndoor Specs\u003c\/h2\u003e\n\u003cdiv class=\"hvx-table-wrap\"\u003e\n\u003ctable aria-label=\"Indoor unit specifications\" class=\"hvx-table\"\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eSpec\u003c\/th\u003e\n\u003cth\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCH-RLS18MIA-230VI\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSystem type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSingle Zone\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRefrigerant type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eR454B\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated capacity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e18,000 BTU\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower source\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e208–230V, 1Ph, 60Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eVoltage range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e187–253 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDehumidification\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e5.29 pnt\/day\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSEER2\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e19.2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEER2\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e10.8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMinimum circuit ampacity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMax fuse\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e15\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRefrigerant piping (liq\/gas)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1\/4\" \/ 1\/2\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIndoor air flow\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e429.7 \/ 388.5 \/ 259 \/ 217.8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIndoor noise level (H\/M\/L)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e45 \/ 36 \/ 24\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eUnit dimensions (W×H×D)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e37.99 × 8.46 × 12.56\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePacking dimensions (W×D×H)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e41.14 × 12.01 × 16.14\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNet \/ Gross weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e24.47 \/ 32.63\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating range (Cooling)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e60–90\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating range (Heating)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e32–86\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDrainage water pipe diameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e5\/8\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"hvx-desc-card\"\u003e\n\u003ch2 class=\"hvx-section-title\"\u003eOutdoor Specs\u003c\/h2\u003e\n\u003cdiv class=\"hvx-table-wrap\"\u003e\n\u003ctable aria-label=\"Outdoor unit specifications\" class=\"hvx-table\"\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eSpec\u003c\/th\u003e\n\u003cth\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCH-RLS18MIA-230VO\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRefrigerant type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eR454B\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated capacity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e18,000 BTU\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower source\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e208–230V, 1Ph, 60Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eVoltage range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e187–253 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDehumidification\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e5.29 pnt\/day\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRefrigerant piping (liq\/gas)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1\/4\" \/ 1\/2\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMax pipe length\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e98.4 ft\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMax height difference (IDU↔ODU)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e65.6\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCooling capacity (Min\/Max)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e18,000 (4,100~19,000)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eHeating capacity (Min\/Max)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e18,800 (6,200~20,200)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eHSPF2-5\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e7.5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eHSPF2-4\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e9.6\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCOP\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3.06\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOutdoor noise level\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e56\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOutdoor air flow\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1,235.3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMinimum circuit ampacity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e15\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMax fuse\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAmbient temp (Heating)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e5 ~ 75\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAmbient temp (Cooling)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e5 ~ 122\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eUnit dimensions (W×H×D)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e31.69 × 12.99 × 21.81\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNet \/ Gross weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e72.31 \/ 78.48\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePacking dimensions (W×D×H)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e37.00 × 16.14 × 23.82\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRefrigerant precharge\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e25\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAdditional charge (1\/4\" liquid)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.16\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"hvx-desc-card\"\u003e\n\u003ch2 class=\"hvx-section-title\"\u003eDocuments \u0026amp; Downloads\u003c\/h2\u003e\n\u003cul style=\"padding-left: 18px; margin: 8px 0;\"\u003e\n\u003cli\u003e\u003ca rel=\"noopener\" href=\"https:\/\/media.cooperandhunter.us\/4719\/CH-RLS18MIA-230VO_CH-RLS18MIA-230VI.pdf\" class=\"hvx-link\" target=\"_blank\"\u003eSubmittal (PDF) — CH-RLS18MIA-230VO + CH-RLS18MIA-230VI\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca rel=\"noopener\" href=\"https:\/\/media.cooperandhunter.us\/4722\/User_manual-MIA%28R454B%29.pdf\" class=\"hvx-link\" target=\"_blank\"\u003eUser Manual (PDF) — MIA (R454B)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca rel=\"noopener\" href=\"https:\/\/media.cooperandhunter.us\/4721\/Remote-controller-manual.pdf\" class=\"hvx-link\" target=\"_blank\"\u003eRemote Controller Manual (PDF)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca rel=\"noopener\" href=\"https:\/\/www.youtube.com\/watch?v=VV3-nC-sKrs\" class=\"hvx-link\" target=\"_blank\"\u003eVideo — MIA Series\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003eAHRI Certified: 207740527 (search AHRI directory)\u003c\/li\u003e\n\u003cli\u003eManufacturer pages: CH-RLS18MIA-230VI, CH-RLS18MIA-230VO\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"hvx-desc-card\"\u003e\n\u003ch2 class=\"hvx-section-title\"\u003eImportant\u003c\/h2\u003e\n\u003cp style=\"margin: 0; font-size: 14px; color: var(--hvx-slate);\"\u003eProfessional installation is recommended. Confirm electrical requirements, line sizes, maximum line length, and ambient operating limits before installation.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"hvx-desc-card\"\u003e\n\u003ch2 class=\"hvx-section-title\"\u003eFAQs\u003c\/h2\u003e\n\u003cdetails open=\"\" class=\"hvx-faq\"\u003e\n\u003csummary\u003eWhat voltage does this system require?\u003c\/summary\u003e\n\u003cdiv style=\"margin-top: 8px;\"\u003e208–230V, single phase, 60Hz.\u003c\/div\u003e\n\u003c\/details\u003e\n\u003cdetails open=\"\" class=\"hvx-faq\"\u003e\n\u003csummary\u003eWhat line sizes does this system use?\u003c\/summary\u003e\n\u003cdiv style=\"margin-top: 8px;\"\u003e1\/4\" liquid and 1\/2\" gas.\u003c\/div\u003e\n\u003c\/details\u003e\n\u003cdetails open=\"\" class=\"hvx-faq\"\u003e\n\u003csummary\u003eWhat is the max line length and height difference?\u003c\/summary\u003e\n\u003cdiv style=\"margin-top: 8px;\"\u003eMaximum line length is 98.4 ft and maximum height difference is 65.6.\u003c\/div\u003e\n\u003c\/details\u003e\n\u003cdetails open=\"\" class=\"hvx-faq\"\u003e\n\u003csummary\u003eWhat are the outdoor ambient operating ranges?\u003c\/summary\u003e\n\u003cdiv style=\"margin-top: 8px;\"\u003eCooling: 5~122. Heating: 5~75.\u003c\/div\u003e\n\u003c\/details\u003e\n\u003cdetails open=\"\" class=\"hvx-faq\"\u003e\n\u003csummary\u003eWhat control options are supported?\u003c\/summary\u003e\n\u003cdiv style=\"margin-top: 8px;\"\u003eSmart Kit app control and remote are supported; a wall thermostat can be purchased separately.\u003c\/div\u003e\n\u003c\/details\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e","brand":"Cooper\u0026Hunter","offers":[{"title":"Default Title","offer_id":42690506522667,"sku":"CH-RLS18MIA-230VI + CH-RLS18MIA-230VO","price":1134.72,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0625\/5647\/1339\/files\/24K230V_6edb26d4-f69a-4c32-8a6d-d082397032c7.png?v=1769199376"},{"product_id":"cooper-hunter-24-000-btu-mia-single-zone-wall-mount-minisplit-heat-pump-system-r454b-230v","title":"Cooper\u0026Hunter 24,000 BTU Mia Single Zone Wall Mount Minisplit Heat Pump System R454B 230V","description":"\u003cstyle\u003e\n  :root{\n    --hvx-golden:#FAA819;\n    --hvx-slate:#262626;\n    --hvx-ivory:#F4F1E6;\n    --hvx-border:#e2e0d5;\n    --hvx-card-bg:#ffffff;\n  }\n\n  .hvx-desc{\n    font-family:\"Articulat CF\",system-ui,-apple-system,BlinkMacSystemFont,\"Segoe UI\",sans-serif;\n    color:var(--hvx-slate);\n    line-height:1.6;\n    background:var(--hvx-ivory);\n    padding:18px 18px 20px;\n    border-radius:16px;\n  }\n\n  .hvx-desc-header{\n    border-radius:14px;\n    padding:14px 16px;\n    background:linear-gradient(120deg,var(--hvx-golden),var(--hvx-slate));\n    color:#fff;\n    margin:0 0 16px;\n    box-shadow:0 10px 24px rgba(0,0,0,.22);\n    display:flex;\n    align-items:flex-start;\n    gap:12px;\n    flex-wrap:wrap;\n  }\n\n  .hvx-header-text{display:flex;flex-direction:column;gap:6px;min-width:260px}\n  .hvx-eyebrow{\n    font-size:11px;\n    letter-spacing:.14em;\n    text-transform:uppercase;\n    opacity:.9;\n  }\n  .hvx-title{\n    margin:0;\n    font-family:\"Anton\",\"Impact\",system-ui,-apple-system,BlinkMacSystemFont,\"Segoe UI\",sans-serif;\n    font-size:22px;\n    line-height:1.15;\n  }\n  .hvx-subtitle{margin:0;font-size:14px;opacity:.95}\n\n  .hvx-desc-card{\n    border:1px solid var(--hvx-border);\n    border-radius:14px;\n    background:var(--hvx-card-bg);\n    padding:16px 18px 18px;\n    box-shadow:0 4px 12px rgba(0,0,0,.06);\n    margin:14px 0;\n  }\n\n  .hvx-section-title{\n    margin:0 0 10px;\n    font-family:\"Anton\",\"Impact\",system-ui,-apple-system,BlinkMacSystemFont,\"Segoe UI\",sans-serif;\n    font-size:17px;\n    letter-spacing:.08em;\n    text-transform:uppercase;\n    color:var(--hvx-slate);\n    display:inline-flex;\n    align-items:center;\n    gap:8px;\n  }\n  .hvx-section-title::after{\n    content:\"\";\n    flex:1;\n    height:2px;\n    border-radius:999px;\n    background:linear-gradient(90deg,var(--hvx-golden),transparent);\n    opacity:.9;\n  }\n\n  .hvx-cta{display:flex;flex-wrap:wrap;gap:10px;margin:10px 0 0}\n  .hvx-cta a{\n    display:inline-flex;\n    align-items:center;\n    gap:8px;\n    padding:10px 14px;\n    border-radius:12px;\n    border:1px solid var(--hvx-border);\n    background:#fff;\n    text-decoration:none;\n    color:var(--hvx-slate);\n    font-size:14px;\n    font-weight:700;\n  }\n  .hvx-cta a.primary{\n    background:var(--hvx-slate);\n    color:#fff;\n    border-color:transparent;\n  }\n\n  .hvx-badges{display:flex;flex-wrap:wrap;gap:8px;margin:10px 0 0}\n  .hvx-badge{\n    font-size:12px;\n    border:1px solid var(--hvx-border);\n    border-radius:999px;\n    padding:6px 10px;\n    background:#fff;\n    white-space:nowrap;\n  }\n\n  .hvx-kv{\n    display:grid;\n    grid-template-columns:repeat(4,minmax(160px,1fr));\n    gap:10px;\n    margin-top:10px;\n  }\n  .hvx-kv \u003e div{\n    border:1px solid var(--hvx-border);\n    background:#fff;\n    border-radius:12px;\n    padding:10px 12px;\n    text-align:center;\n  }\n  .hvx-kv strong{display:block}\n\n  .hvx-table{\n    width:100%;\n    border-collapse:collapse;\n    min-width:520px;\n    background:#fff;\n    border:1px solid var(--hvx-border);\n    border-radius:12px;\n    overflow:hidden;\n  }\n  .hvx-table th,.hvx-table td{\n    border-bottom:1px solid var(--hvx-border);\n    padding:10px 12px;\n    vertical-align:top;\n    font-size:14px;\n  }\n  .hvx-table th{ text-align:left; font-weight:800; background:#fff; }\n  .hvx-table tr:nth-child(even) td{ background:#fbfaf6; }\n  .hvx-table tr:last-child td{ border-bottom:none; }\n  .hvx-table-wrap{ overflow:auto; border-radius:12px; }\n\n  .hvx-link{color:var(--hvx-slate); text-decoration:underline; text-underline-offset:2px}\n  .hvx-link:hover{opacity:.85}\n\n  details.hvx-faq{\n    border:1px solid var(--hvx-border);\n    background:#fff;\n    border-radius:12px;\n    padding:10px 12px;\n    margin:8px 0;\n  }\n  details.hvx-faq summary{cursor:pointer;font-weight:800}\n\n  @media(max-width:980px){\n    .hvx-kv{grid-template-columns:repeat(2,minmax(160px,1fr))}\n  }\n  @media(max-width:768px){\n    .hvx-desc{padding:14px 12px 16px;border-radius:12px}\n    .hvx-desc-header{padding:12px;border-radius:12px}\n    .hvx-title{font-size:19px}\n    .hvx-desc-card{padding:14px;margin:10px 0}\n  }\n\u003c\/style\u003e\n\u003cdiv class=\"hvx-desc\"\u003e\n\u003cdiv class=\"hvx-desc-header\"\u003e\n\u003cdiv class=\"hvx-header-text\"\u003e\n\u003cdiv class=\"hvx-eyebrow\"\u003eCooper\u0026amp;Hunter MIA • Matte • R454B • 230V\u003c\/div\u003e\n\u003ch1 class=\"hvx-title\"\u003eCooper\u0026amp;Hunter 24,000 BTU MIA Single Zone Wall Mount Mini Split Heat Pump System R454B 230V\u003c\/h1\u003e\n\u003cp class=\"hvx-subtitle\"\u003e\u003cstrong\u003eSKU:\u003c\/strong\u003e CH-RLS24MIA-230VI + CH-RLS24MIA-230VO\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"hvx-cta\" aria-label=\"Contact options\"\u003e\n\u003ca class=\"primary\" href=\"https:\/\/hvacsupplies.com\/pages\/contact\" rel=\"noopener\" title=\"Contact Us\" target=\"_blank\"\u003e CLICK HERE TO CONTACT US FOR CUSTOM QUOTES AND QUESTIONS \u003c\/a\u003e \u003ca href=\"tel:+18005438933\" title=\"Call Us Now!\"\u003e CLICK TO CALL US 800-543-8933 FOR ANY QUESTIONS \u003c\/a\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"hvx-desc-card\"\u003e\n\u003ch2 class=\"hvx-section-title\"\u003eOverview\u003c\/h2\u003e\n\u003cp style=\"margin: 0;\"\u003eThe Cooper\u0026amp;Hunter \u003cstrong\u003e24K BTU MIA\u003c\/strong\u003e wall-mounted mini split system is a one-to-one, \u003cstrong\u003esingle-zone\u003c\/strong\u003e solution featuring a clean \u003cstrong\u003ematte\u003c\/strong\u003e indoor finish and efficient inverter operation. It uses \u003cstrong\u003eR454B refrigerant\u003c\/strong\u003e and delivers up to \u003cstrong\u003e18.7 SEER2\u003c\/strong\u003e for dependable comfort and energy savings.\u003c\/p\u003e\n\u003cp style=\"margin: 10px 0 0;\"\u003eComfort and convenience features include \u003cstrong\u003eTurbo Mode\u003c\/strong\u003e, \u003cstrong\u003eAuto Swing\u003c\/strong\u003e horizontal louvers, multiple fan speeds, \u003cstrong\u003eSleep Mode\u003c\/strong\u003e, \u003cstrong\u003eSelf-Clean\u003c\/strong\u003e, and \u003cstrong\u003eFollow Me\u003c\/strong\u003e temperature sensing from the remote. The included \u003cstrong\u003eSmart Kit\u003c\/strong\u003e supports control via the downloadable C\u0026amp;H app.\u003c\/p\u003e\n\u003cp style=\"margin: 10px 0 0;\"\u003eMIA series coils are protected by \u003cstrong\u003eGoldFin\u003c\/strong\u003e anti-corrosive coating, and the indoor unit uses \u003cstrong\u003eTU1 copper tubing\u003c\/strong\u003e for durability and efficient heat transfer.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"hvx-desc-card\"\u003e\n\u003ch2 class=\"hvx-section-title\"\u003eHighlights\u003c\/h2\u003e\n\u003cdiv class=\"hvx-badges\" role=\"list\"\u003e\n\u003cspan class=\"hvx-badge\" role=\"listitem\"\u003e24,000 BTU class\u003c\/span\u003e \u003cspan class=\"hvx-badge\" role=\"listitem\"\u003eR454B refrigerant\u003c\/span\u003e \u003cspan class=\"hvx-badge\" role=\"listitem\"\u003eSEER2 18.7\u003c\/span\u003e \u003cspan class=\"hvx-badge\" role=\"listitem\"\u003eEER2 10.0\u003c\/span\u003e \u003cspan class=\"hvx-badge\" role=\"listitem\"\u003eInverter technology\u003c\/span\u003e \u003cspan class=\"hvx-badge\" role=\"listitem\"\u003eSmart Kit included\u003c\/span\u003e \u003cspan class=\"hvx-badge\" role=\"listitem\"\u003eAuto Swing (horizontal)\u003c\/span\u003e \u003cspan class=\"hvx-badge\" role=\"listitem\"\u003eGoldFin coil protection\u003c\/span\u003e \u003cspan class=\"hvx-badge\" role=\"listitem\"\u003e208–230V, 1Ph, 60Hz\u003c\/span\u003e\n\u003c\/div\u003e\n\u003cul style=\"margin: 12px 0 0; padding-left: 18px;\"\u003e\n\u003cli\u003e\n\u003cstrong\u003eEfficient comfort:\u003c\/strong\u003e inverter-driven operation adjusts output to match demand.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRapid performance:\u003c\/strong\u003e Turbo Mode for quick cooling\/heating changes.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBalanced airflow:\u003c\/strong\u003e Auto Swing helps distribute air evenly.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnected control:\u003c\/strong\u003e Smart Kit app control + included remote.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBuilt to last:\u003c\/strong\u003e GoldFin coil protection and TU1 copper tubing.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cdiv class=\"hvx-kv\" role=\"list\" aria-label=\"At-a-glance\"\u003e\n\u003cdiv role=\"listitem\"\u003e\n\u003cstrong\u003eIndoor\u003c\/strong\u003eCH-RLS24MIA-230VI\u003c\/div\u003e\n\u003cdiv role=\"listitem\"\u003e\n\u003cstrong\u003eOutdoor\u003c\/strong\u003eCH-RLS24MIA-230VO\u003c\/div\u003e\n\u003cdiv role=\"listitem\"\u003e\n\u003cstrong\u003eLines\u003c\/strong\u003e3\/8\" liquid · 5\/8\" gas\u003c\/div\u003e\n\u003cdiv role=\"listitem\"\u003e\n\u003cstrong\u003eMax run\u003c\/strong\u003e164 ft\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"hvx-desc-card\"\u003e\n\u003ch2 class=\"hvx-section-title\"\u003eWhat’s Included\u003c\/h2\u003e\n\u003cul style=\"padding-left: 18px; margin: 8px 0;\"\u003e\n\u003cli\u003eIndoor unit: CH-RLS24MIA-230VI\u003c\/li\u003e\n\u003cli\u003eOutdoor unit: CH-RLS24MIA-230VO\u003c\/li\u003e\n\u003cli\u003eRemote control (included)\u003c\/li\u003e\n\u003cli\u003eSmart Kit for app control\u003c\/li\u003e\n\u003cli\u003eLine set, communication cable (16 ft.), and drain line\u003c\/li\u003e\n\u003cli\u003eManufacturer documentation (see Documents \u0026amp; Downloads)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"hvx-desc-card\"\u003e\n\u003ch2 class=\"hvx-section-title\"\u003eIndoor Specs\u003c\/h2\u003e\n\u003cdiv class=\"hvx-table-wrap\"\u003e\n\u003ctable class=\"hvx-table\" aria-label=\"Indoor unit specifications\"\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eSpec\u003c\/th\u003e\n\u003cth\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCH-RLS24MIA-230VI\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSystem type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSingle Zone\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRefrigerant type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eR454B\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated capacity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e24,000 BTU\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower source\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e208–230V, 1Ph, 60Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eVoltage range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e187–253 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDehumidification\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e6.34 pnt\/day\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSEER2\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e18.7\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEER2\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e10\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMinimum circuit ampacity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMax fuse\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e15\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRefrigerant piping (liq\/gas)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3\/8\" \/ 5\/8\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIndoor air flow\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e729.9 \/ 529.7 \/ 400.2 \/ 329.6\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIndoor noise level (H\/M\/L)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e45 \/ 41.5 \/ 27\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eUnit dimensions (W×H×D)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e42.52 × 8.90 × 13.19\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePacking dimensions (W×D×H)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e45.47 × 16.34 × 12.60\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNet \/ Gross weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e30.64 \/ 39.46\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating range (Cooling)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e60–90\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating range (Heating)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e32–86\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDrainage water pipe diameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e5\/8\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"hvx-desc-card\"\u003e\n\u003ch2 class=\"hvx-section-title\"\u003eOutdoor Specs\u003c\/h2\u003e\n\u003cdiv class=\"hvx-table-wrap\"\u003e\n\u003ctable class=\"hvx-table\" aria-label=\"Outdoor unit specifications\"\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eSpec\u003c\/th\u003e\n\u003cth\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCH-RLS24MIA-230VO\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRefrigerant type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eR454B\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated capacity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e24,000 BTU\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower source\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e208–230V, 1Ph, 60Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eVoltage range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e187–253 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDehumidification\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e6.34 pnt\/day\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRefrigerant piping (liq\/gas)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3\/8\" \/ 5\/8\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMax pipe length\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e164 ft\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMax height difference (IDU↔ODU)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e82\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCooling capacity (Min\/Max)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e24,000 (5,500~24,200)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eHeating capacity (Min\/Max)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e24,000 (6,300~27,000)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eHSPF2-5\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e7.3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eHSPF2-4\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e9.3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCOP\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3.31\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOutdoor noise level\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e59.5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOutdoor air flow\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1,764.7\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMinimum circuit ampacity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e19\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMax fuse\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAmbient temp (Heating)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e5 ~ 75\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAmbient temp (Cooling)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e5 ~ 122\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eUnit dimensions (W×H×D)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e35.04 × 13.46 × 26.50\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNet \/ Gross weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e94.58 \/ 102.29\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePacking dimensions (W×D×H)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e40.55 × 17.24 × 28.74\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRefrigerant precharge\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e25\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAdditional charge (3\/8\" liquid)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.32\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"hvx-desc-card\"\u003e\n\u003ch2 class=\"hvx-section-title\"\u003eDocuments \u0026amp; Downloads\u003c\/h2\u003e\n\u003cul style=\"padding-left: 18px; margin: 8px 0;\"\u003e\n\u003cli\u003e\u003ca class=\"hvx-link\" href=\"https:\/\/media.cooperandhunter.us\/4720\/CH-RLS24MIA-230VO_CH-RLS24MIA-230VI.pdf\" rel=\"noopener\" target=\"_blank\"\u003eSubmittal (PDF) — CH-RLS24MIA-230VO + CH-RLS24MIA-230VI\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca class=\"hvx-link\" href=\"https:\/\/media.cooperandhunter.us\/4722\/User_manual-MIA%28R454B%29.pdf\" rel=\"noopener\" target=\"_blank\"\u003eUser Manual (PDF) — MIA (R454B)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca class=\"hvx-link\" href=\"https:\/\/media.cooperandhunter.us\/4721\/Remote-controller-manual.pdf\" rel=\"noopener\" target=\"_blank\"\u003eRemote Controller Manual (PDF)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca class=\"hvx-link\" href=\"https:\/\/www.youtube.com\/watch?v=VV3-nC-sKrs\" rel=\"noopener\" target=\"_blank\"\u003eVideo — MIA Series\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003eAHRI Certified: 207740528 (search AHRI directory)\u003c\/li\u003e\n\u003cli\u003eManufacturer pages: CH-RLS24MIA-230VI, CH-RLS24MIA-230VO\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"hvx-desc-card\"\u003e\n\u003ch2 class=\"hvx-section-title\"\u003eImportant\u003c\/h2\u003e\n\u003cp style=\"margin: 0; font-size: 14px; color: var(--hvx-slate);\"\u003eProfessional installation is recommended. Confirm electrical requirements, line sizes, maximum line length, and ambient operating limits before installation.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"hvx-desc-card\"\u003e\n\u003ch2 class=\"hvx-section-title\"\u003eFAQs\u003c\/h2\u003e\n\u003cdetails class=\"hvx-faq\" open=\"\"\u003e\n\u003csummary\u003eWhat voltage does this system require?\u003c\/summary\u003e\n\u003cdiv style=\"margin-top: 8px;\"\u003e208–230V, single phase, 60Hz.\u003c\/div\u003e\n\u003c\/details\u003e\n\u003cdetails class=\"hvx-faq\" open=\"\"\u003e\n\u003csummary\u003eWhat line sizes does this system use?\u003c\/summary\u003e\n\u003cdiv style=\"margin-top: 8px;\"\u003e3\/8\" liquid and 5\/8\" gas.\u003c\/div\u003e\n\u003c\/details\u003e\n\u003cdetails class=\"hvx-faq\" open=\"\"\u003e\n\u003csummary\u003eWhat is the max line length and height difference?\u003c\/summary\u003e\n\u003cdiv style=\"margin-top: 8px;\"\u003eMaximum line length is 164 ft and maximum height difference is 82.\u003c\/div\u003e\n\u003c\/details\u003e\n\u003cdetails class=\"hvx-faq\" open=\"\"\u003e\n\u003csummary\u003eWhat are the outdoor ambient operating ranges?\u003c\/summary\u003e\n\u003cdiv style=\"margin-top: 8px;\"\u003eCooling: 5~122. Heating: 5~75.\u003c\/div\u003e\n\u003c\/details\u003e\n\u003cdetails class=\"hvx-faq\" open=\"\"\u003e\n\u003csummary\u003eWhat control options are supported?\u003c\/summary\u003e\n\u003cdiv style=\"margin-top: 8px;\"\u003eSmart Kit app control and remote are supported; a wall thermostat can be purchased separately.\u003c\/div\u003e\n\u003c\/details\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e","brand":"Cooper\u0026Hunter","offers":[{"title":"Default Title","offer_id":42690549645355,"sku":"CH-RLS24MIA-230VI + CH-RLS24MIA-230VO","price":1476.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0625\/5647\/1339\/files\/24K230V_6edb26d4-f69a-4c32-8a6d-d082397032c7.png?v=1769199376"},{"product_id":"cooper-hunter-9-000-btu-hyper-single-zone-four-way-ceiling-cassette-w-humidity-sensor-minisplit-heat-pump-system-r454b-230v","title":"Cooper\u0026Hunter 9,000 BTU Hyper Single Zone Four-Way Ceiling Cassette w\/ Humidity Sensor Minisplit Heat Pump System R454B 230V","description":"\u003cstyle\u003e\n  :root{\n    --hvx-golden:#FAA819;\n    --hvx-slate:#262626;\n    --hvx-ivory:#F4F1E6;\n    --hvx-border:#e2e0d5;\n    --hvx-card-bg:#ffffff;\n  }\n  .hvx-desc{font-family:\"Articulat CF\",system-ui,-apple-system,BlinkMacSystemFont,\"Segoe UI\",sans-serif;color:var(--hvx-slate);line-height:1.6;background:var(--hvx-ivory);padding:18px 18px 20px;border-radius:16px}\n  .hvx-desc-header{border-radius:14px;padding:14px 16px;background:linear-gradient(120deg,var(--hvx-golden),var(--hvx-slate));color:#fff;margin:0 0 16px;box-shadow:0 10px 24px rgba(0,0,0,.22);display:flex;align-items:flex-start;gap:12px;flex-wrap:wrap}\n  .hvx-header-text{display:flex;flex-direction:column;gap:6px;min-width:260px}\n  .hvx-eyebrow{font-size:11px;letter-spacing:.14em;text-transform:uppercase;opacity:.9}\n  .hvx-title{margin:0;font-family:\"Anton\",\"Impact\",system-ui,-apple-system,BlinkMacSystemFont,\"Segoe UI\",sans-serif;font-size:22px;line-height:1.15}\n  .hvx-subtitle{margin:0;font-size:14px;opacity:.95}\n  .hvx-desc-card{border:1px solid var(--hvx-border);border-radius:14px;background:var(--hvx-card-bg);padding:16px 18px 18px;box-shadow:0 4px 12px rgba(0,0,0,.06);margin:14px 0}\n  .hvx-section-title{margin:0 0 10px;font-family:\"Anton\",\"Impact\",system-ui,-apple-system,BlinkMacSystemFont,\"Segoe UI\",sans-serif;font-size:17px;letter-spacing:.08em;text-transform:uppercase;color:var(--hvx-slate);display:inline-flex;align-items:center;gap:8px}\n  .hvx-section-title::after{content:\"\";flex:1;height:2px;border-radius:999px;background:linear-gradient(90deg,var(--hvx-golden),transparent);opacity:.9}\n  .hvx-cta{display:flex;flex-wrap:wrap;gap:10px;margin:10px 0 0}\n  .hvx-cta a{display:inline-flex;align-items:center;gap:8px;padding:10px 14px;border-radius:12px;border:1px solid var(--hvx-border);background:#fff;text-decoration:none;color:var(--hvx-slate);font-size:14px;font-weight:700}\n  .hvx-cta a.primary{background:var(--hvx-slate);color:#fff;border-color:transparent}\n  .hvx-badges{display:flex;flex-wrap:wrap;gap:8px;margin:10px 0 0}\n  .hvx-badge{font-size:12px;border:1px solid var(--hvx-border);border-radius:999px;padding:6px 10px;background:#fff;white-space:nowrap}\n  .hvx-kv{display:grid;grid-template-columns:repeat(4,minmax(160px,1fr));gap:10px;margin-top:10px}\n  .hvx-kv\u003ediv{border:1px solid var(--hvx-border);background:#fff;border-radius:12px;padding:10px 12px;text-align:center}\n  .hvx-kv strong{display:block}\n  .hvx-table{width:100%;border-collapse:collapse;min-width:520px;background:#fff;border:1px solid var(--hvx-border);border-radius:12px;overflow:hidden}\n  .hvx-table th,.hvx-table td{border-bottom:1px solid var(--hvx-border);padding:10px 12px;vertical-align:top;font-size:14px}\n  .hvx-table th{text-align:left;font-weight:800;background:#fff}\n  .hvx-table tr:nth-child(even) td{background:#fbfaf6}\n  .hvx-table tr:last-child td{border-bottom:none}\n  .hvx-table-wrap{overflow:auto;border-radius:12px}\n  details.hvx-faq{border:1px solid var(--hvx-border);background:#fff;border-radius:12px;padding:10px 12px;margin:8px 0}\n  details.hvx-faq summary{cursor:pointer;font-weight:800}\n  @media(max-width:980px){.hvx-kv{grid-template-columns:repeat(2,minmax(160px,1fr))}}\n  @media(max-width:768px){.hvx-desc{padding:14px 12px 16px;border-radius:12px}.hvx-desc-header{padding:12px;border-radius:12px}.hvx-title{font-size:19px}.hvx-desc-card{padding:14px;margin:10px 0}}\n\u003c\/style\u003e\n\u003cdiv class=\"hvx-desc\"\u003e\n\u003cdiv class=\"hvx-desc-header\"\u003e\n\u003cdiv class=\"hvx-header-text\"\u003e\n\u003cdiv class=\"hvx-eyebrow\"\u003eFour-Way Ceiling Cassette • Humidity Sensor • R454B • 230V\u003c\/div\u003e\n\u003ch1 class=\"hvx-title\"\u003eCooper\u0026amp;Hunter 9,000 BTU Hyper Single Zone Four-Way Ceiling Cassette w\/ Humidity Sensor Minisplit Heat Pump System R454B 230V\u003c\/h1\u003e\n\u003cp class=\"hvx-subtitle\"\u003e\u003cstrong\u003eIndoor:\u003c\/strong\u003e CH-RH09MCT  |  \u003cstrong\u003eOutdoor:\u003c\/strong\u003e CH-RHP09-230VO\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"hvx-cta\"\u003e\n\u003ca rel=\"noopener\" href=\"https:\/\/hvacsupplies.com\/pages\/contact\" class=\"primary\" target=\"_blank\"\u003eCLICK HERE TO CONTACT US FOR CUSTOM QUOTES AND QUESTIONS\u003c\/a\u003e \u003ca href=\"tel:+18005438933\"\u003eCLICK TO CALL US 800-543-8933 FOR ANY QUESTIONS\u003c\/a\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"hvx-desc-card\"\u003e\n\u003ch2 class=\"hvx-section-title\"\u003eOverview\u003c\/h2\u003e\n\u003cp style=\"margin: 0;\"\u003eThis system pairs the \u003cstrong\u003eCH-RH09MCT 4-way ceiling cassette\u003c\/strong\u003e with the \u003cstrong\u003eCH-RHP09-230VO Hyper Heating outdoor unit\u003c\/strong\u003e for efficient, single-zone comfort using \u003cstrong\u003eR454B refrigerant\u003c\/strong\u003e. The cassette delivers omni-directional airflow through a \u003cstrong\u003e360° air flow panel\u003c\/strong\u003e and includes a \u003cstrong\u003ehumidity sensor\u003c\/strong\u003e to support balanced comfort.\u003c\/p\u003e\n\u003cp style=\"margin: 10px 0 0;\"\u003eBuilt for performance and reliability, the cassette features \u003cstrong\u003eGoldFin\u003c\/strong\u003e anti-corrosive protection, TU1 copper tubing, fresh air intake capability, and a \u003cstrong\u003ebuilt-in condensate pump\u003c\/strong\u003e with float switch (20.9\" lift). Hyper Heating operation supports dependable comfort in very low outdoor temperatures.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"hvx-desc-card\"\u003e\n\u003ch2 class=\"hvx-section-title\"\u003eHighlights\u003c\/h2\u003e\n\u003cdiv role=\"list\" class=\"hvx-badges\"\u003e\n\u003cspan role=\"listitem\" class=\"hvx-badge\"\u003e9,000 BTU class\u003c\/span\u003e \u003cspan role=\"listitem\" class=\"hvx-badge\"\u003eR454B refrigerant\u003c\/span\u003e \u003cspan role=\"listitem\" class=\"hvx-badge\"\u003eCeiling cassette (4-way)\u003c\/span\u003e \u003cspan role=\"listitem\" class=\"hvx-badge\"\u003eHumidity sensor\u003c\/span\u003e \u003cspan role=\"listitem\" class=\"hvx-badge\"\u003e360° airflow panel\u003c\/span\u003e \u003cspan role=\"listitem\" class=\"hvx-badge\"\u003eGoldFin coil protection\u003c\/span\u003e \u003cspan role=\"listitem\" class=\"hvx-badge\"\u003eBuilt-in condensate pump\u003c\/span\u003e \u003cspan role=\"listitem\" class=\"hvx-badge\"\u003e208–230V, 1Ph, 60Hz\u003c\/span\u003e\n\u003c\/div\u003e\n\u003cul style=\"margin: 12px 0 0; padding-left: 18px;\"\u003e\n\u003cli\u003e\n\u003cstrong\u003eClean air support:\u003c\/strong\u003e activated carbon filter and fresh air intake capability.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eComfort modes:\u003c\/strong\u003e Sleep Mode, Turbo Operation, multiple fan speeds, anti-cold-air heating behavior.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSmart control:\u003c\/strong\u003e built-in Smart Kit (C\u0026amp;H app), remote, and wall thermostat.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCold-weather capable:\u003c\/strong\u003e Hyper Heating outdoor operation down to \u003cstrong\u003e-22°F\u003c\/strong\u003e heating \/ cooling ambient.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cdiv aria-label=\"At-a-glance\" role=\"list\" class=\"hvx-kv\"\u003e\n\u003cdiv role=\"listitem\"\u003e\n\u003cstrong\u003eIndoor\u003c\/strong\u003eCH-RH09MCT\u003c\/div\u003e\n\u003cdiv role=\"listitem\"\u003e\n\u003cstrong\u003eOutdoor\u003c\/strong\u003eCH-RHP09-230VO\u003c\/div\u003e\n\u003cdiv role=\"listitem\"\u003e\n\u003cstrong\u003eLineset\u003c\/strong\u003e1\/4\" liquid · 3\/8\" gas\u003c\/div\u003e\n\u003cdiv role=\"listitem\"\u003e\n\u003cstrong\u003eMax run\u003c\/strong\u003e82 ft\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"hvx-desc-card\"\u003e\n\u003ch2 class=\"hvx-section-title\"\u003eWhat’s Included\u003c\/h2\u003e\n\u003cul style=\"padding-left: 18px; margin: 8px 0;\"\u003e\n\u003cli\u003eIndoor 4-way ceiling cassette: CH-RH09MCT\u003c\/li\u003e\n\u003cli\u003eOutdoor condenser: CH-RHP09-230VO (Hyper Heating)\u003c\/li\u003e\n\u003cli\u003eBuilt-in Smart Kit for app control\u003c\/li\u003e\n\u003cli\u003eRemote control and wall thermostat\u003c\/li\u003e\n\u003cli\u003eCeiling Cassette Panel\u003c\/li\u003e\n\u003cli\u003eBuilt-in condensate pump with float switch\u003c\/li\u003e\n\u003cli\u003eManufacturer documentation (see Documents \u0026amp; Downloads)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"hvx-desc-card\"\u003e\n\u003ch2 class=\"hvx-section-title\"\u003eIndoor Specs\u003c\/h2\u003e\n\u003cdiv class=\"hvx-table-wrap\"\u003e\n\u003ctable aria-label=\"Indoor unit specifications\" class=\"hvx-table\"\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eSpec\u003c\/th\u003e\n\u003cth\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCH-RH09MCT\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSystem type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSingle Zone\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRefrigerant type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eR454B\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated capacity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e9,000 BTU\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower source\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e208–230V, 1Ph, 60Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eVoltage range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e187–253 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDehumidification\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1.86 pnt\/day\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSEER2\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e22.6\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEER2\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e14\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRefrigerant piping (liq\/gas)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1\/4\" \/ 3\/8\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMinimum circuit ampacity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMax fuse\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e15\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIndoor noise level (H\/M\/L)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e40 \/ 37.5 \/ 26\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIndoor air flow\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e353.2 \/ 312 \/ 264.9 \/ 182.5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eUnit dimensions (W×H×D)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e22.44 × 22.44 × 9.65\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePacking dimensions (W×D×H)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e28.15 × 25.20 × 11.61\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNet \/ Gross weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e35.27 \/ 41.89\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating range (Cooling)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e60–90\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating range (Heating)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e32–86\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDrain size\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eController\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eWire controller + remote controller available\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"hvx-desc-card\"\u003e\n\u003ch2 class=\"hvx-section-title\"\u003eOutdoor Specs\u003c\/h2\u003e\n\u003cdiv class=\"hvx-table-wrap\"\u003e\n\u003ctable aria-label=\"Outdoor unit specifications\" class=\"hvx-table\"\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eSpec\u003c\/th\u003e\n\u003cth\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCH-RHP09-230VO\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRefrigerant type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eR454B\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated capacity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e9,000 BTU\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower source\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e208–230V, 1Ph, 60Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eVoltage range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e187–253 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMax pipe length\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e82 ft\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMax height difference (IDU↔ODU)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e49.2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCooling capacity (Min\/Max)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e9,000 (3,800~13,500)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eHeating capacity (Min\/Max)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e12,000 (3,800~16,000)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eHSPF2-5\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e9.5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eHSPF2-4\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e12.5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCOP\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3.76\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOutdoor noise level\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e56\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOutdoor air flow\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1,470.6\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMinimum circuit ampacity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e15\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMax fuse\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e15\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAmbient temp (Heating)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-22~75\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAmbient temp (Cooling)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-22~122\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eUnit dimensions (W×H×D)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e31.69 × 12.99 × 21.81\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNet \/ Gross weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e72.75 \/ 78.70\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRefrigerant precharge\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e25\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAdditional charge (1\/4\" liquid)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.16\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"hvx-desc-card\"\u003e\n\u003ch2 class=\"hvx-section-title\"\u003eDocuments \u0026amp; Downloads\u003c\/h2\u003e\n\u003cul style=\"padding-left: 18px; margin: 8px 0;\"\u003e\n\u003cli\u003e\u003ca rel=\"noopener\" href=\"https:\/\/media.cooperandhunter.us\/4682\/CH-RHP09-230VO_CH-RH09MCT.pdf\" class=\"hvx-link\" target=\"_blank\"\u003eSubmittal (PDF) — CH-RHP09-230VO + CH-RH09MCT\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca rel=\"noopener\" href=\"https:\/\/media.cooperandhunter.us\/4654\/Installation-manual-R454B-Ceiling-cassette_compressed.pdf\" class=\"hvx-link\" target=\"_blank\"\u003eInstallation Manual (PDF) — R454B Ceiling Cassette\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca rel=\"noopener\" href=\"https:\/\/media.cooperandhunter.us\/4655\/Owners_-manual-R454B-Ceiling-cassette_compressed.pdf\" class=\"hvx-link\" target=\"_blank\"\u003eOwner’s Manual (PDF) — R454B Ceiling Cassette\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca rel=\"noopener\" href=\"https:\/\/media.cooperandhunter.us\/4195\/120N-wire-controller---owners-manual.pdf\" class=\"hvx-link\" target=\"_blank\"\u003e120N Wire Controller Owner’s Manual (PDF)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca rel=\"noopener\" href=\"https:\/\/media.cooperandhunter.us\/3198\/MultiZone-Combination-HYPER.pdf\" class=\"hvx-link\" target=\"_blank\"\u003eMultiZone Combination (PDF) — Hyper\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca rel=\"noopener\" href=\"https:\/\/media.cooperandhunter.us\/3199\/MultiZone-Combination-Regular.pdf\" class=\"hvx-link\" target=\"_blank\"\u003eMultiZone Combination (PDF) — Regular\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003eAHRI Certified: 207742320\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"hvx-desc-card\"\u003e\n\u003ch2 class=\"hvx-section-title\"\u003eImportant\u003c\/h2\u003e\n\u003cp style=\"margin: 0; font-size: 14px;\"\u003eConfirm ceiling clearance, drain routing for the built-in pump, electrical requirements, and lineset sizing before installation. Professional installation is recommended.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"hvx-desc-card\"\u003e\n\u003ch2 class=\"hvx-section-title\"\u003eFAQs\u003c\/h2\u003e\n\u003cdetails open=\"\" class=\"hvx-faq\"\u003e\n\u003csummary\u003eDoes this cassette include a humidity sensor?\u003c\/summary\u003e\n\u003cdiv style=\"margin-top: 8px;\"\u003eYes—this ceiling cassette configuration includes a humidity sensor feature set for comfort control.\u003c\/div\u003e\n\u003c\/details\u003e\n\u003cdetails open=\"\" class=\"hvx-faq\"\u003e\n\u003csummary\u003eWhat voltage does this system use?\u003c\/summary\u003e\n\u003cdiv style=\"margin-top: 8px;\"\u003e208–230V, single phase, 60Hz.\u003c\/div\u003e\n\u003c\/details\u003e\n\u003cdetails open=\"\" class=\"hvx-faq\"\u003e\n\u003csummary\u003eWhat lineset size does it use?\u003c\/summary\u003e\n\u003cdiv style=\"margin-top: 8px;\"\u003e1\/4\" liquid and 3\/8\" suction.\u003c\/div\u003e\n\u003c\/details\u003e\n\u003cdetails open=\"\" class=\"hvx-faq\"\u003e\n\u003csummary\u003eHow cold can the Hyper outdoor unit operate?\u003c\/summary\u003e\n\u003cdiv style=\"margin-top: 8px;\"\u003eHeating ambient down to -22°F and cooling ambient down to -22°F.\u003c\/div\u003e\n\u003c\/details\u003e\n\u003cdetails open=\"\" class=\"hvx-faq\"\u003e\n\u003csummary\u003eIs a wall thermostat supported?\u003c\/summary\u003e\n\u003cdiv style=\"margin-top: 8px;\"\u003eYes—control options include the C\u0026amp;H app (built-in Smart Kit), remote control, and a wall thermostat.\u003c\/div\u003e\n\u003c\/details\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e","brand":"Cooper\u0026Hunter","offers":[{"title":"No Installation","offer_id":42690575007787,"sku":"CH-RH09MCT + CH-RHP09-230VO","price":1857.0,"currency_code":"USD","in_stock":true},{"title":"16FT","offer_id":42690575040555,"sku":"CH-RH09MCT + CH-RHP09-230VO","price":2039.0,"currency_code":"USD","in_stock":true},{"title":"25FT","offer_id":42690575073323,"sku":"CH-RH09MCT + CH-RHP09-230VO","price":2085.0,"currency_code":"USD","in_stock":true},{"title":"50FT","offer_id":42690575106091,"sku":"CH-RH09MCT + CH-RHP09-230VO","price":2305.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0625\/5647\/1339\/files\/2-ZoneDuctlessMiniSplitAC_HeatPump48000BTU_26.png?v=1769199192"},{"product_id":"cooper-hunter-9-000-btu-single-zone-four-way-ceiling-cassette-w-humidity-sensor-minisplit-heat-pump-system-r454b-230v","title":"Cooper\u0026Hunter 9,000 BTU Single Zone Four-Way Ceiling Cassette w\/ Humidity Sensor Minisplit Heat Pump System R454B 230V","description":"\u003c!-- Same title; Regular outdoor pairing --\u003e\n\u003cstyle\u003e\n  :root{--hvx-golden:#FAA819;--hvx-slate:#262626;--hvx-ivory:#F4F1E6;--hvx-border:#e2e0d5;--hvx-card-bg:#ffffff;}\n  .hvx-desc{font-family:\"Articulat CF\",system-ui,-apple-system,BlinkMacSystemFont,\"Segoe UI\",sans-serif;color:var(--hvx-slate);line-height:1.6;background:var(--hvx-ivory);padding:18px 18px 20px;border-radius:16px}\n  .hvx-desc-header{border-radius:14px;padding:14px 16px;background:linear-gradient(120deg,var(--hvx-golden),var(--hvx-slate));color:#fff;margin:0 0 16px;box-shadow:0 10px 24px rgba(0,0,0,.22);display:flex;align-items:flex-start;gap:12px;flex-wrap:wrap}\n  .hvx-header-text{display:flex;flex-direction:column;gap:6px;min-width:260px}\n  .hvx-eyebrow{font-size:11px;letter-spacing:.14em;text-transform:uppercase;opacity:.9}\n  .hvx-title{margin:0;font-family:\"Anton\",\"Impact\",system-ui,-apple-system,BlinkMacSystemFont,\"Segoe UI\",sans-serif;font-size:22px;line-height:1.15}\n  .hvx-subtitle{margin:0;font-size:14px;opacity:.95}\n  .hvx-desc-card{border:1px solid var(--hvx-border);border-radius:14px;background:var(--hvx-card-bg);padding:16px 18px 18px;box-shadow:0 4px 12px rgba(0,0,0,.06);margin:14px 0}\n  .hvx-section-title{margin:0 0 10px;font-family:\"Anton\",\"Impact\",system-ui,-apple-system,BlinkMacSystemFont,\"Segoe UI\",sans-serif;font-size:17px;letter-spacing:.08em;text-transform:uppercase;color:var(--hvx-slate);display:inline-flex;align-items:center;gap:8px}\n  .hvx-section-title::after{content:\"\";flex:1;height:2px;border-radius:999px;background:linear-gradient(90deg,var(--hvx-golden),transparent);opacity:.9}\n  .hvx-cta{display:flex;flex-wrap:wrap;gap:10px;margin:10px 0 0}\n  .hvx-cta a{display:inline-flex;align-items:center;gap:8px;padding:10px 14px;border-radius:12px;border:1px solid var(--hvx-border);background:#fff;text-decoration:none;color:var(--hvx-slate);font-size:14px;font-weight:700}\n  .hvx-cta a.primary{background:var(--hvx-slate);color:#fff;border-color:transparent}\n  .hvx-badges{display:flex;flex-wrap:wrap;gap:8px;margin:10px 0 0}\n  .hvx-badge{font-size:12px;border:1px solid var(--hvx-border);border-radius:999px;padding:6px 10px;background:#fff;white-space:nowrap}\n  .hvx-kv{display:grid;grid-template-columns:repeat(4,minmax(160px,1fr));gap:10px;margin-top:10px}\n  .hvx-kv\u003ediv{border:1px solid var(--hvx-border);background:#fff;border-radius:12px;padding:10px 12px;text-align:center}\n  .hvx-kv strong{display:block}\n  .hvx-table{width:100%;border-collapse:collapse;min-width:520px;background:#fff;border:1px solid var(--hvx-border);border-radius:12px;overflow:hidden}\n  .hvx-table th,.hvx-table td{border-bottom:1px solid var(--hvx-border);padding:10px 12px;vertical-align:top;font-size:14px}\n  .hvx-table th{text-align:left;font-weight:800;background:#fff}\n  .hvx-table tr:nth-child(even) td{background:#fbfaf6}\n  .hvx-table tr:last-child td{border-bottom:none}\n  .hvx-table-wrap{overflow:auto;border-radius:12px}\n  details.hvx-faq{border:1px solid var(--hvx-border);background:#fff;border-radius:12px;padding:10px 12px;margin:8px 0}\n  details.hvx-faq summary{cursor:pointer;font-weight:800}\n  @media(max-width:980px){.hvx-kv{grid-template-columns:repeat(2,minmax(160px,1fr))}}\n  @media(max-width:768px){.hvx-desc{padding:14px 12px 16px;border-radius:12px}.hvx-desc-header{padding:12px;border-radius:12px}.hvx-title{font-size:19px}.hvx-desc-card{padding:14px;margin:10px 0}}\n\u003c\/style\u003e\n\u003cdiv class=\"hvx-desc\"\u003e\n\u003cdiv class=\"hvx-desc-header\"\u003e\n\u003cdiv class=\"hvx-header-text\"\u003e\n\u003cdiv class=\"hvx-eyebrow\"\u003eFour-Way Ceiling Cassette • Humidity Sensor • R454B • 230V\u003c\/div\u003e\n\u003ch1 class=\"hvx-title\"\u003eCooper\u0026amp;Hunter 9,000 BTU Single Zone Four-Way Ceiling Cassette w\/ Humidity Sensor Minisplit Heat Pump System R454B 230V\u003c\/h1\u003e\n\u003cp class=\"hvx-subtitle\"\u003e\u003cstrong\u003eIndoor:\u003c\/strong\u003e CH-RH09MCT  |  \u003cstrong\u003eOutdoor:\u003c\/strong\u003e CH-RES09-230VO\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"hvx-cta\"\u003e\n\u003ca class=\"primary\" href=\"https:\/\/hvacsupplies.com\/pages\/contact\" rel=\"noopener\" target=\"_blank\"\u003eCLICK HERE TO CONTACT US FOR CUSTOM QUOTES AND QUESTIONS\u003c\/a\u003e \u003ca href=\"tel:+18005438933\"\u003eCLICK TO CALL US 800-543-8933 FOR ANY QUESTIONS\u003c\/a\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"hvx-desc-card\"\u003e\n\u003ch2 class=\"hvx-section-title\"\u003eOverview\u003c\/h2\u003e\n\u003cp style=\"margin: 0;\"\u003eThis single-zone system pairs the \u003cstrong\u003eCH-RH09MCT 4-way ceiling cassette\u003c\/strong\u003e with the \u003cstrong\u003eCH-RES09-230VO Regular outdoor unit\u003c\/strong\u003e for efficient heating and cooling using \u003cstrong\u003eR454B refrigerant\u003c\/strong\u003e. The cassette delivers omni-directional comfort through a \u003cstrong\u003e360° air flow panel\u003c\/strong\u003e and includes a \u003cstrong\u003ehumidity sensor\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp style=\"margin: 10px 0 0;\"\u003eDesigned for durability and easy service, it includes \u003cstrong\u003eGoldFin\u003c\/strong\u003e anti-corrosive coating, TU1 copper tubing, fresh air intake capability, and a \u003cstrong\u003ebuilt-in condensate pump\u003c\/strong\u003e with float switch (20.9\" lift).\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"hvx-desc-card\"\u003e\n\u003ch2 class=\"hvx-section-title\"\u003eHighlights\u003c\/h2\u003e\n\u003cdiv class=\"hvx-badges\" role=\"list\"\u003e\n\u003cspan class=\"hvx-badge\" role=\"listitem\"\u003e9,000 BTU class\u003c\/span\u003e \u003cspan class=\"hvx-badge\" role=\"listitem\"\u003eSEER2 (outdoor): 21.6\u003c\/span\u003e \u003cspan class=\"hvx-badge\" role=\"listitem\"\u003eHumidity sensor\u003c\/span\u003e \u003cspan class=\"hvx-badge\" role=\"listitem\"\u003eActivated carbon filter\u003c\/span\u003e \u003cspan class=\"hvx-badge\" role=\"listitem\"\u003eGoldFin protection\u003c\/span\u003e \u003cspan class=\"hvx-badge\" role=\"listitem\"\u003eBuilt-in pump + float switch\u003c\/span\u003e \u003cspan class=\"hvx-badge\" role=\"listitem\"\u003eApp + remote + thermostat\u003c\/span\u003e\n\u003c\/div\u003e\n\u003cul style=\"margin: 12px 0 0; padding-left: 18px;\"\u003e\n\u003cli\u003e\n\u003cstrong\u003eEven coverage:\u003c\/strong\u003e omni-directional distribution with a 360° panel.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eComfort modes:\u003c\/strong\u003e Sleep Mode, Turbo Operation, multiple fan speeds, anti-cold-air heating behavior.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEfficient inverter outdoor:\u003c\/strong\u003e solid heating\/cooling performance with wide ambient operation.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutdoor ambient range:\u003c\/strong\u003e heating to \u003cstrong\u003e-13°F\u003c\/strong\u003e; cooling to \u003cstrong\u003e-13°F\u003c\/strong\u003e.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cdiv class=\"hvx-kv\" role=\"list\" aria-label=\"At-a-glance\"\u003e\n\u003cdiv role=\"listitem\"\u003e\n\u003cstrong\u003eIndoor\u003c\/strong\u003eCH-RH09MCT\u003c\/div\u003e\n\u003cdiv role=\"listitem\"\u003e\n\u003cstrong\u003eOutdoor\u003c\/strong\u003eCH-RES09-230VO\u003c\/div\u003e\n\u003cdiv role=\"listitem\"\u003e\n\u003cstrong\u003eLineset\u003c\/strong\u003e1\/4\" liquid · 3\/8\" gas\u003c\/div\u003e\n\u003cdiv role=\"listitem\"\u003e\n\u003cstrong\u003eMax run\u003c\/strong\u003e82 ft\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"hvx-desc-card\"\u003e\n\u003ch2 class=\"hvx-section-title\"\u003eWhat’s Included\u003c\/h2\u003e\n\u003cul style=\"padding-left: 18px; margin: 8px 0;\"\u003e\n\u003cli\u003eIndoor 4-way ceiling cassette: CH-RH09MCT\u003c\/li\u003e\n\u003cli\u003eOutdoor condenser: CH-RES09-230VO (Regular)\u003c\/li\u003e\n\u003cli\u003eBuilt-in Smart Kit for app control\u003c\/li\u003e\n\u003cli\u003eRemote control and wall thermostat\u003c\/li\u003e\n\u003cli\u003eCeiling Cassette Panel\u003c\/li\u003e\n\u003cli\u003eBuilt-in condensate pump with float switch\u003c\/li\u003e\n\u003cli\u003eManufacturer documentation (see Documents \u0026amp; Downloads)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"hvx-desc-card\"\u003e\n\u003ch2 class=\"hvx-section-title\"\u003eIndoor Specs\u003c\/h2\u003e\n\u003cdiv class=\"hvx-table-wrap\"\u003e\n\u003ctable class=\"hvx-table\" aria-label=\"Indoor unit specifications\"\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eSpec\u003c\/th\u003e\n\u003cth\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCH-RH09MCT\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRefrigerant type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eR454B\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated capacity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e9,000 BTU\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower source\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e208–230V, 1Ph, 60Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSEER2\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e22.6\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEER2\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e14\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePiping (liq\/gas)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1\/4\" \/ 3\/8\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNoise (H\/M\/L)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e40 \/ 37.5 \/ 26\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAir flow\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e353.2 \/ 312 \/ 264.9 \/ 182.5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (W×H×D)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e22.44 × 22.44 × 9.65\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDrain size\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"hvx-desc-card\"\u003e\n\u003ch2 class=\"hvx-section-title\"\u003eOutdoor Specs\u003c\/h2\u003e\n\u003cdiv class=\"hvx-table-wrap\"\u003e\n\u003ctable class=\"hvx-table\" aria-label=\"Outdoor unit specifications\"\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eSpec\u003c\/th\u003e\n\u003cth\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCH-RES09-230VO\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRefrigerant type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eR454B\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated capacity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e9,000 BTU\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSEER2\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e19.5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEER2\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e12.8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eHSPF2-5 \/ HSPF2-4\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e8.8 \/ 11\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCOP\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3.66\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCooling capacity (Min\/Max)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e9,000 (3,100~11,900)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eHeating capacity (Min\/Max)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e10,000 (3,600~14,000)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAmbient temp (Heating)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-13~75\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAmbient temp (Cooling)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-13~122\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMax pipe length\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e82 ft\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMin circuit \/ Max fuse\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e12 \/ 15\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNoise\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e54\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (W×H×D)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e30.12 × 11.93 × 21.85\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNet \/ Gross weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e62.17 \/ 67.68\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"hvx-desc-card\"\u003e\n\u003ch2 class=\"hvx-section-title\"\u003eDocuments \u0026amp; Downloads\u003c\/h2\u003e\n\u003cul style=\"padding-left: 18px; margin: 8px 0;\"\u003e\n\u003cli\u003e\u003ca class=\"hvx-link\" href=\"https:\/\/media.cooperandhunter.us\/4675\/CH-RES09-230VO_CH-RH09MCT.pdf\" rel=\"noopener\" target=\"_blank\"\u003eSubmittal (PDF) — CH-RES09-230VO + CH-RH09MCT\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca class=\"hvx-link\" href=\"https:\/\/media.cooperandhunter.us\/4118\/Installation-Manual-R454B-Outdoor-units--.pdf\" rel=\"noopener\" target=\"_blank\"\u003eInstallation Manual (PDF) — R454B Outdoor Units\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca class=\"hvx-link\" href=\"https:\/\/media.cooperandhunter.us\/4654\/Installation-manual-R454B-Ceiling-cassette_compressed.pdf\" rel=\"noopener\" target=\"_blank\"\u003eInstallation Manual (PDF) — R454B Ceiling Cassette\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca class=\"hvx-link\" href=\"https:\/\/media.cooperandhunter.us\/4655\/Owners_-manual-R454B-Ceiling-cassette_compressed.pdf\" rel=\"noopener\" target=\"_blank\"\u003eOwner’s Manual (PDF) — R454B Ceiling Cassette\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca class=\"hvx-link\" href=\"https:\/\/media.cooperandhunter.us\/4195\/120N-wire-controller---owners-manual.pdf\" rel=\"noopener\" target=\"_blank\"\u003e120N Wire Controller Owner’s Manual (PDF)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca class=\"hvx-link\" href=\"https:\/\/media.cooperandhunter.us\/3198\/MultiZone-Combination-HYPER.pdf\" rel=\"noopener\" target=\"_blank\"\u003eMultiZone Combination (PDF) — Hyper\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca class=\"hvx-link\" href=\"https:\/\/media.cooperandhunter.us\/3199\/MultiZone-Combination-Regular.pdf\" rel=\"noopener\" target=\"_blank\"\u003eMultiZone Combination (PDF) — Regular\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003eAHRI Certified: 207742317\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"hvx-desc-card\"\u003e\n\u003ch2 class=\"hvx-section-title\"\u003eImportant\u003c\/h2\u003e\n\u003cp style=\"margin: 0; font-size: 14px;\"\u003eVerify ceiling opening requirements, condensate drain routing, and electrical specs before installation. Professional installation is recommended.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"hvx-desc-card\"\u003e\n\u003ch2 class=\"hvx-section-title\"\u003eFAQs\u003c\/h2\u003e\n\u003cdetails class=\"hvx-faq\" open=\"\"\u003e\n\u003csummary\u003eDoes this configuration support smart control?\u003c\/summary\u003e\n\u003cdiv style=\"margin-top: 8px;\"\u003eYes—built-in Smart Kit supports the C\u0026amp;H app, plus remote and wall thermostat control.\u003c\/div\u003e\n\u003c\/details\u003e\n\u003cdetails class=\"hvx-faq\" open=\"\"\u003e\n\u003csummary\u003eWhat’s the outdoor ambient heating range?\u003c\/summary\u003e\n\u003cdiv style=\"margin-top: 8px;\"\u003eDown to -13°F (Regular outdoor unit).\u003c\/div\u003e\n\u003c\/details\u003e\n\u003cdetails class=\"hvx-faq\" open=\"\"\u003e\n\u003csummary\u003eWhat lineset size is used?\u003c\/summary\u003e\n\u003cdiv style=\"margin-top: 8px;\"\u003e1\/4\" liquid and 3\/8\" suction.\u003c\/div\u003e\n\u003c\/details\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e","brand":"Cooper\u0026Hunter","offers":[{"title":"No Installation","offer_id":42690591031339,"sku":"CH-RH09MCT + CH-RES09-230VO","price":1572.0,"currency_code":"USD","in_stock":true},{"title":"16FT","offer_id":42690591064107,"sku":"CH-RH09MCT + CH-RES09-230VO","price":1754.0,"currency_code":"USD","in_stock":true},{"title":"25FT","offer_id":42690591096875,"sku":"CH-RH09MCT + CH-RES09-230VO","price":1800.0,"currency_code":"USD","in_stock":true},{"title":"50FT","offer_id":42690591129643,"sku":"CH-RH09MCT + CH-RES09-230VO","price":2020.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0625\/5647\/1339\/files\/FourWay_Regular_Product_Hero_48_33b3a9f5-7a1c-442f-a881-e51e604eb6c3.png?v=1769199174"},{"product_id":"cooper-hunter-9-000-btu-dip-switch-9k-12k-pro-hyper-single-zone-four-way-ceiling-cassette-w-refrigerant-humidity-sensor-minisplit-heat-pump-system-r454b-230v","title":"Cooper\u0026Hunter 9,000 BTU Dip Switch (9k-12k) Hyper Pro Single Zone Four-Way Ceiling Cassette w\/ Refrigerant \u0026 Humidity Sensor Minisplit Heat Pump System R454B 230V","description":"\u003cstyle\u003e\n  :root{--hvx-golden:#FAA819;--hvx-slate:#262626;--hvx-ivory:#F4F1E6;--hvx-border:#e2e0d5;--hvx-card-bg:#ffffff;}\n  .hvx-desc{font-family:\"Articulat CF\",system-ui,-apple-system,BlinkMacSystemFont,\"Segoe UI\",sans-serif;color:var(--hvx-slate);line-height:1.6;background:var(--hvx-ivory);padding:18px 18px 20px;border-radius:16px}\n  .hvx-desc-header{border-radius:14px;padding:14px 16px;background:linear-gradient(120deg,var(--hvx-golden),var(--hvx-slate));color:#fff;margin:0 0 16px;box-shadow:0 10px 24px rgba(0,0,0,.22);display:flex;align-items:flex-start;gap:12px;flex-wrap:wrap}\n  .hvx-header-text{display:flex;flex-direction:column;gap:6px;min-width:260px}\n  .hvx-eyebrow{font-size:11px;letter-spacing:.14em;text-transform:uppercase;opacity:.9}\n  .hvx-title{margin:0;font-family:\"Anton\",\"Impact\",system-ui,-apple-system,BlinkMacSystemFont,\"Segoe UI\",sans-serif;font-size:22px;line-height:1.15}\n  .hvx-subtitle{margin:0;font-size:14px;opacity:.95}\n  .hvx-desc-card{border:1px solid var(--hvx-border);border-radius:14px;background:var(--hvx-card-bg);padding:16px 18px 18px;box-shadow:0 4px 12px rgba(0,0,0,.06);margin:14px 0}\n  .hvx-section-title{margin:0 0 10px;font-family:\"Anton\",\"Impact\",system-ui,-apple-system,BlinkMacSystemFont,\"Segoe UI\",sans-serif;font-size:17px;letter-spacing:.08em;text-transform:uppercase;color:var(--hvx-slate);display:inline-flex;align-items:center;gap:8px}\n  .hvx-section-title::after{content:\"\";flex:1;height:2px;border-radius:999px;background:linear-gradient(90deg,var(--hvx-golden),transparent);opacity:.9}\n  .hvx-cta{display:flex;flex-wrap:wrap;gap:10px;margin:10px 0 0}\n  .hvx-cta a{display:inline-flex;align-items:center;gap:8px;padding:10px 14px;border-radius:12px;border:1px solid var(--hvx-border);background:#fff;text-decoration:none;color:var(--hvx-slate);font-size:14px;font-weight:700}\n  .hvx-cta a.primary{background:var(--hvx-slate);color:#fff;border-color:transparent}\n  .hvx-badges{display:flex;flex-wrap:wrap;gap:8px;margin:10px 0 0}\n  .hvx-badge{font-size:12px;border:1px solid var(--hvx-border);border-radius:999px;padding:6px 10px;background:#fff;white-space:nowrap}\n  .hvx-kv{display:grid;grid-template-columns:repeat(4,minmax(160px,1fr));gap:10px;margin-top:10px}\n  .hvx-kv\u003ediv{border:1px solid var(--hvx-border);background:#fff;border-radius:12px;padding:10px 12px;text-align:center}\n  .hvx-kv strong{display:block}\n  .hvx-table{width:100%;border-collapse:collapse;min-width:520px;background:#fff;border:1px solid var(--hvx-border);border-radius:12px;overflow:hidden}\n  .hvx-table th,.hvx-table td{border-bottom:1px solid var(--hvx-border);padding:10px 12px;vertical-align:top;font-size:14px}\n  .hvx-table th{text-align:left;font-weight:800;background:#fff}\n  .hvx-table tr:nth-child(even) td{background:#fbfaf6}\n  .hvx-table tr:last-child td{border-bottom:none}\n  .hvx-table-wrap{overflow:auto;border-radius:12px}\n  details.hvx-faq{border:1px solid var(--hvx-border);background:#fff;border-radius:12px;padding:10px 12px;margin:8px 0}\n  details.hvx-faq summary{cursor:pointer;font-weight:800}\n  @media(max-width:980px){.hvx-kv{grid-template-columns:repeat(2,minmax(160px,1fr))}}\n  @media(max-width:768px){.hvx-desc{padding:14px 12px 16px;border-radius:12px}.hvx-desc-header{padding:12px;border-radius:12px}.hvx-title{font-size:19px}.hvx-desc-card{padding:14px;margin:10px 0}}\n\u003c\/style\u003e\n\u003cdiv class=\"hvx-desc\"\u003e\n\u003cdiv class=\"hvx-desc-header\"\u003e\n\u003cdiv class=\"hvx-header-text\"\u003e\n\u003cdiv class=\"hvx-eyebrow\"\u003eFour-Way Ceiling Cassette • Pro Refrigerant \u0026amp; Humidity Sensor • R454B • 230V\u003c\/div\u003e\n\u003ch1 class=\"hvx-title\"\u003eCooper\u0026amp;Hunter 9,000 BTU Dip Switch (9k-12k) Hyper Pro Single Zone Four-Way Ceiling Cassette w\/ Refrigerant \u0026amp; Humidity Sensor Minisplit Heat Pump System R454B 230V\u003c\/h1\u003e\n\u003cp class=\"hvx-subtitle\"\u003e\u003cstrong\u003eIndoor:\u003c\/strong\u003e CH-RSH09-12MCT  |  \u003cstrong\u003eOutdoor:\u003c\/strong\u003e CH-RHP09-230VO\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"hvx-cta\"\u003e\n\u003ca rel=\"noopener\" href=\"https:\/\/hvacsupplies.com\/pages\/contact\" class=\"primary\" target=\"_blank\"\u003eCLICK HERE TO CONTACT US FOR CUSTOM QUOTES AND QUESTIONS\u003c\/a\u003e \u003ca href=\"tel:+18005438933\"\u003eCLICK TO CALL US 800-543-8933 FOR ANY QUESTIONS\u003c\/a\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"hvx-desc-card\"\u003e\n\u003ch2 class=\"hvx-section-title\"\u003eOverview\u003c\/h2\u003e\n\u003cp style=\"margin: 0;\"\u003eThis configuration pairs the \u003cstrong\u003eCH-RSH09-12MCT 4-way ceiling cassette\u003c\/strong\u003e with the \u003cstrong\u003eCH-RHP09-230VO Hyper Heating outdoor unit\u003c\/strong\u003e using \u003cstrong\u003eR454B refrigerant\u003c\/strong\u003e. This cassette supports \u003cstrong\u003ecapacity adjustment (9K–12K)\u003c\/strong\u003e via an \u003cstrong\u003eENC1 dip switch\u003c\/strong\u003e for tailored performance.\u003c\/p\u003e\n\u003cp style=\"margin: 10px 0 0;\"\u003eThe cassette features omni-directional comfort through a \u003cstrong\u003e360° panel\u003c\/strong\u003e, plus an activated carbon filter, GoldFin protection, TU1 copper tubing, fresh air intake capability, and a \u003cstrong\u003ebuilt-in condensate pump\u003c\/strong\u003e with float switch (20.9\" lift). This model also includes \u003cstrong\u003erefrigerant leakage detection\u003c\/strong\u003e and self-diagnosis support.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"hvx-desc-card\"\u003e\n\u003ch2 class=\"hvx-section-title\"\u003eHighlights\u003c\/h2\u003e\n\u003cdiv role=\"list\" class=\"hvx-badges\"\u003e\n\u003cspan role=\"listitem\" class=\"hvx-badge\"\u003eConfigurable 9K–12K\u003c\/span\u003e \u003cspan role=\"listitem\" class=\"hvx-badge\"\u003eR454B refrigerant\u003c\/span\u003e \u003cspan role=\"listitem\" class=\"hvx-badge\"\u003eSEER2 (cassette): 22.2\u003c\/span\u003e \u003cspan role=\"listitem\" class=\"hvx-badge\"\u003eRefrigerant \u0026amp; Humidity sensor\u003c\/span\u003e \u003cspan role=\"listitem\" class=\"hvx-badge\"\u003eLeak detection\u003c\/span\u003e \u003cspan role=\"listitem\" class=\"hvx-badge\"\u003eBuilt-in pump\u003c\/span\u003e \u003cspan role=\"listitem\" class=\"hvx-badge\"\u003eHyper Heating outdoor\u003c\/span\u003e \u003cspan role=\"listitem\" class=\"hvx-badge\"\u003e208–230V\u003c\/span\u003e\n\u003c\/div\u003e\n\u003cul style=\"margin: 12px 0 0; padding-left: 18px;\"\u003e\n\u003cli\u003e\n\u003cstrong\u003eAdjustable capacity:\u003c\/strong\u003e set output to match demand (9K–12K class cassette).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEven airflow:\u003c\/strong\u003e omni-directional distribution with a 360° panel.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSmart control:\u003c\/strong\u003e built-in Smart Kit (C\u0026amp;H app), plus remote and wall thermostat.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCold-weather capable:\u003c\/strong\u003e Hyper outdoor ambient down to \u003cstrong\u003e-22°F\u003c\/strong\u003e heating \/ cooling.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cdiv aria-label=\"At-a-glance\" role=\"list\" class=\"hvx-kv\"\u003e\n\u003cdiv role=\"listitem\"\u003e\n\u003cstrong\u003eIndoor\u003c\/strong\u003eCH-RSH09-12MCT\u003c\/div\u003e\n\u003cdiv role=\"listitem\"\u003e\n\u003cstrong\u003eOutdoor\u003c\/strong\u003eCH-RHP09-230VO\u003c\/div\u003e\n\u003cdiv role=\"listitem\"\u003e\n\u003cstrong\u003eLineset\u003c\/strong\u003e1\/4\" liquid · 3\/8\" gas\u003c\/div\u003e\n\u003cdiv role=\"listitem\"\u003e\n\u003cstrong\u003eMax run\u003c\/strong\u003e82 ft\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"hvx-desc-card\"\u003e\n\u003ch2 class=\"hvx-section-title\"\u003eWhat’s Included\u003c\/h2\u003e\n\u003cul style=\"padding-left: 18px; margin: 8px 0;\"\u003e\n\u003cli\u003eIndoor 4-way ceiling cassette: CH-RSH09-12MCT\u003c\/li\u003e\n\u003cli\u003eOutdoor condenser: CH-RHP09-230VO (Hyper Heating)\u003c\/li\u003e\n\u003cli\u003eBuilt-in Smart Kit for app control\u003c\/li\u003e\n\u003cli\u003eRemote control and wall thermostat\u003c\/li\u003e\n\u003cli\u003eCeiling Cassette Panel\u003c\/li\u003e\n\u003cli\u003eBuilt-in condensate pump with float switch\u003c\/li\u003e\n\u003cli\u003eManufacturer documentation (see Documents \u0026amp; Downloads)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"hvx-desc-card\"\u003e\n\u003ch2 class=\"hvx-section-title\"\u003eIndoor Specs\u003c\/h2\u003e\n\u003cdiv class=\"hvx-table-wrap\"\u003e\n\u003ctable aria-label=\"Indoor unit specifications\" class=\"hvx-table\"\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eSpec\u003c\/th\u003e\n\u003cth\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCH-RSH09-12MCT\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSystem type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSingle Zone\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRefrigerant type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eR454B\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated capacity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e12,000 BTU (configurable 9,000–12,000 via dip switch)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower source\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e208–230V, 1Ph, 60Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eVoltage range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e187–253 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDehumidification\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3.07 pnt\/day\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSEER2\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e22.2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEER2\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e12.5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePiping (liq\/gas)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1\/4\" \/ 3\/8\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNoise (H\/M\/L)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e43.5 \/ 40.5 \/ 27.5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAir flow\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e417.9 \/ 364.9 \/ 306.1 \/ 194.2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (W×H×D)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e22.44 × 22.44 × 9.65\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDrain size\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eController\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eWire controller + remote controller available\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"hvx-desc-card\"\u003e\n\u003ch2 class=\"hvx-section-title\"\u003eOutdoor Specs\u003c\/h2\u003e\n\u003cdiv class=\"hvx-table-wrap\"\u003e\n\u003ctable aria-label=\"Outdoor unit specifications\" class=\"hvx-table\"\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eSpec\u003c\/th\u003e\n\u003cth\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCH-RHP09-230VO\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRefrigerant type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eR454B\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated capacity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e9,000 BTU\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCooling capacity (Min\/Max)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e9,000 (3,800~13,500)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eHeating capacity (Min\/Max)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e12,000 (3,800~16,000)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eHSPF2-5 \/ HSPF2-4\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e9.5 \/ 12.5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCOP\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3.76\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAmbient temp (Heating)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-22~75\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAmbient temp (Cooling)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-22~122\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMax pipe length\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e82 ft\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMin circuit \/ Max fuse\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e15 \/ 15\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNoise\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e56\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (W×H×D)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e31.69 × 12.99 × 21.81\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNet \/ Gross weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e72.75 \/ 78.70\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"hvx-desc-card\"\u003e\n\u003ch2 class=\"hvx-section-title\"\u003eDocuments \u0026amp; Downloads\u003c\/h2\u003e\n\u003cul style=\"padding-left: 18px; margin: 8px 0;\"\u003e\n\u003cli\u003e\u003ca rel=\"noopener\" href=\"https:\/\/media.cooperandhunter.us\/4683\/CH-RHP09-230VO_CH-RSH09MCT.pdf\" class=\"hvx-link\" target=\"_blank\"\u003eSubmittal (PDF) — CH-RHP09-230VO + CH-RSH09MCT\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca rel=\"noopener\" href=\"https:\/\/media.cooperandhunter.us\/4654\/Installation-manual-R454B-Ceiling-cassette_compressed.pdf\" class=\"hvx-link\" target=\"_blank\"\u003eInstallation Manual (PDF) — R454B Ceiling Cassette\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca rel=\"noopener\" href=\"https:\/\/media.cooperandhunter.us\/4655\/Owners_-manual-R454B-Ceiling-cassette_compressed.pdf\" class=\"hvx-link\" target=\"_blank\"\u003eOwner’s Manual (PDF) — R454B Ceiling Cassette\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca rel=\"noopener\" href=\"https:\/\/media.cooperandhunter.us\/4125\/120N-wire-controller---owners-manual.pdf\" class=\"hvx-link\" target=\"_blank\"\u003e120N Wire Controller Owner’s Manual (PDF)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca rel=\"noopener\" href=\"https:\/\/media.cooperandhunter.us\/3198\/MultiZone-Combination-HYPER.pdf\" class=\"hvx-link\" target=\"_blank\"\u003eMultiZone Combination (PDF) — Hyper\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca rel=\"noopener\" href=\"https:\/\/media.cooperandhunter.us\/3199\/MultiZone-Combination-Regular.pdf\" class=\"hvx-link\" target=\"_blank\"\u003eMultiZone Combination (PDF) — Regular\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003eAHRI Certified (outdoor): 207742320\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"hvx-desc-card\"\u003e\n\u003ch2 class=\"hvx-section-title\"\u003eImportant\u003c\/h2\u003e\n\u003cp style=\"margin: 0; font-size: 14px;\"\u003eIf using the adjustable-capacity cassette, set the dip switch configuration during installation and confirm electrical and airflow requirements before commissioning.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"hvx-desc-card\"\u003e\n\u003ch2 class=\"hvx-section-title\"\u003eFAQs\u003c\/h2\u003e\n\u003cdetails open=\"\" class=\"hvx-faq\"\u003e\n\u003csummary\u003eIs this a true 9K system if the cassette lists 12K?\u003c\/summary\u003e\n\u003cdiv style=\"margin-top: 8px;\"\u003eThis cassette model supports capacity changes (9K–12K) via an ENC1 dip switch, allowing configuration to match the application.\u003c\/div\u003e\n\u003c\/details\u003e\n\u003cdetails open=\"\" class=\"hvx-faq\"\u003e\n\u003csummary\u003eDoes this include leak detection?\u003c\/summary\u003e\n\u003cdiv style=\"margin-top: 8px;\"\u003eYes—this cassette configuration includes refrigerant leakage detection and self-diagnosis support.\u003c\/div\u003e\n\u003c\/details\u003e\n\u003cdetails open=\"\" class=\"hvx-faq\"\u003e\n\u003csummary\u003eWhat’s the cold-weather operating limit with the Hyper outdoor?\u003c\/summary\u003e\n\u003cdiv style=\"margin-top: 8px;\"\u003eHeating ambient down to -22°F; cooling ambient down to -22°F.\u003c\/div\u003e\n\u003c\/details\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e","brand":"Cooper\u0026Hunter","offers":[{"title":"No Installation","offer_id":42690601680939,"sku":"CH-RSH09-12MCT + CH-RHP09-230VO","price":2002.0,"currency_code":"USD","in_stock":true},{"title":"16FT","offer_id":42690601713707,"sku":"CH-RSH09-12MCT + CH-RHP09-230VO","price":2183.0,"currency_code":"USD","in_stock":true},{"title":"25FT","offer_id":42690601746475,"sku":"CH-RSH09-12MCT + CH-RHP09-230VO","price":2230.0,"currency_code":"USD","in_stock":true},{"title":"50FT","offer_id":42690601779243,"sku":"CH-RSH09-12MCT + CH-RHP09-230VO","price":2450.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0625\/5647\/1339\/files\/2-ZoneDuctlessMiniSplitAC_HeatPump48000BTU_26.png?v=1769199192"},{"product_id":"cooper-hunter-9-000-btu-dip-switch-9k-12k-pro-single-zone-four-way-ceiling-cassette-w-refrigerant-humidity-sensor-minisplit-heat-pump-system-r454b-230v","title":"Cooper\u0026Hunter 9,000 BTU Dip Switch (9k-12k) Pro Single Zone Four-Way Ceiling Cassette w\/ Refrigerant \u0026 Humidity Sensor Minisplit Heat Pump System R454B 230V","description":"\u003cstyle\u003e\n  :root{--hvx-golden:#FAA819;--hvx-slate:#262626;--hvx-ivory:#F4F1E6;--hvx-border:#e2e0d5;--hvx-card-bg:#ffffff;}\n  .hvx-desc{font-family:\"Articulat CF\",system-ui,-apple-system,BlinkMacSystemFont,\"Segoe UI\",sans-serif;color:var(--hvx-slate);line-height:1.6;background:var(--hvx-ivory);padding:18px 18px 20px;border-radius:16px}\n  .hvx-desc-header{border-radius:14px;padding:14px 16px;background:linear-gradient(120deg,var(--hvx-golden),var(--hvx-slate));color:#fff;margin:0 0 16px;box-shadow:0 10px 24px rgba(0,0,0,.22);display:flex;align-items:flex-start;gap:12px;flex-wrap:wrap}\n  .hvx-header-text{display:flex;flex-direction:column;gap:6px;min-width:260px}\n  .hvx-eyebrow{font-size:11px;letter-spacing:.14em;text-transform:uppercase;opacity:.9}\n  .hvx-title{margin:0;font-family:\"Anton\",\"Impact\",system-ui,-apple-system,BlinkMacSystemFont,\"Segoe UI\",sans-serif;font-size:22px;line-height:1.15}\n  .hvx-subtitle{margin:0;font-size:14px;opacity:.95}\n  .hvx-desc-card{border:1px solid var(--hvx-border);border-radius:14px;background:var(--hvx-card-bg);padding:16px 18px 18px;box-shadow:0 4px 12px rgba(0,0,0,.06);margin:14px 0}\n  .hvx-section-title{margin:0 0 10px;font-family:\"Anton\",\"Impact\",system-ui,-apple-system,BlinkMacSystemFont,\"Segoe UI\",sans-serif;font-size:17px;letter-spacing:.08em;text-transform:uppercase;color:var(--hvx-slate);display:inline-flex;align-items:center;gap:8px}\n  .hvx-section-title::after{content:\"\";flex:1;height:2px;border-radius:999px;background:linear-gradient(90deg,var(--hvx-golden),transparent);opacity:.9}\n  .hvx-cta{display:flex;flex-wrap:wrap;gap:10px;margin:10px 0 0}\n  .hvx-cta a{display:inline-flex;align-items:center;gap:8px;padding:10px 14px;border-radius:12px;border:1px solid var(--hvx-border);background:#fff;text-decoration:none;color:var(--hvx-slate);font-size:14px;font-weight:700}\n  .hvx-cta a.primary{background:var(--hvx-slate);color:#fff;border-color:transparent}\n  .hvx-badges{display:flex;flex-wrap:wrap;gap:8px;margin:10px 0 0}\n  .hvx-badge{font-size:12px;border:1px solid var(--hvx-border);border-radius:999px;padding:6px 10px;background:#fff;white-space:nowrap}\n  .hvx-kv{display:grid;grid-template-columns:repeat(4,minmax(160px,1fr));gap:10px;margin-top:10px}\n  .hvx-kv\u003ediv{border:1px solid var(--hvx-border);background:#fff;border-radius:12px;padding:10px 12px;text-align:center}\n  .hvx-kv strong{display:block}\n  .hvx-table{width:100%;border-collapse:collapse;min-width:520px;background:#fff;border:1px solid var(--hvx-border);border-radius:12px;overflow:hidden}\n  .hvx-table th,.hvx-table td{border-bottom:1px solid var(--hvx-border);padding:10px 12px;vertical-align:top;font-size:14px}\n  .hvx-table th{text-align:left;font-weight:800;background:#fff}\n  .hvx-table tr:nth-child(even) td{background:#fbfaf6}\n  .hvx-table tr:last-child td{border-bottom:none}\n  .hvx-table-wrap{overflow:auto;border-radius:12px}\n  details.hvx-faq{border:1px solid var(--hvx-border);background:#fff;border-radius:12px;padding:10px 12px;margin:8px 0}\n  details.hvx-faq summary{cursor:pointer;font-weight:800}\n  @media(max-width:980px){.hvx-kv{grid-template-columns:repeat(2,minmax(160px,1fr))}}\n  @media(max-width:768px){.hvx-desc{padding:14px 12px 16px;border-radius:12px}.hvx-desc-header{padding:12px;border-radius:12px}.hvx-title{font-size:19px}.hvx-desc-card{padding:14px;margin:10px 0}}\n\u003c\/style\u003e\n\u003cdiv class=\"hvx-desc\"\u003e\n\u003cdiv class=\"hvx-desc-header\"\u003e\n\u003cdiv class=\"hvx-header-text\"\u003e\n\u003cdiv class=\"hvx-eyebrow\"\u003eFour-Way Ceiling Cassette • Humidity Sensor • R454B • 230V\u003c\/div\u003e\n\u003ch1 class=\"hvx-title\"\u003eCooper\u0026amp;Hunter 9,000 BTU Single Zone Pro Four-Way Ceiling Cassette w\/ Refrigerant \u0026amp; Humidity Sensor Minisplit Heat Pump System R454B 230V\u003c\/h1\u003e\n\u003cp class=\"hvx-subtitle\"\u003e\u003cstrong\u003eIndoor:\u003c\/strong\u003e CH-RSH09-12MCT  |  \u003cstrong\u003eOutdoor:\u003c\/strong\u003e CH-RES09-230VO\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"hvx-cta\"\u003e\n\u003ca rel=\"noopener\" href=\"https:\/\/hvacsupplies.com\/pages\/contact\" class=\"primary\" target=\"_blank\"\u003eCLICK HERE TO CONTACT US FOR CUSTOM QUOTES AND QUESTIONS\u003c\/a\u003e \u003ca href=\"tel:+18005438933\"\u003eCLICK TO CALL US 800-543-8933 FOR ANY QUESTIONS\u003c\/a\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"hvx-desc-card\"\u003e\n\u003ch2 class=\"hvx-section-title\"\u003eOverview\u003c\/h2\u003e\n\u003cp style=\"margin: 0;\"\u003eThis pairing combines the \u003cstrong\u003eCH-RSH09-12MCT adjustable-capacity ceiling cassette\u003c\/strong\u003e with the \u003cstrong\u003eCH-RES09-230VO Regular outdoor unit\u003c\/strong\u003e to deliver efficient single-zone comfort on \u003cstrong\u003eR454B refrigerant\u003c\/strong\u003e. The cassette supports \u003cstrong\u003ecapacity adjustment (9K–12K)\u003c\/strong\u003e via ENC1 dip switch settings.\u003c\/p\u003e\n\u003cp style=\"margin: 10px 0 0;\"\u003eIt features a 360° air flow panel for even distribution, an activated carbon filter, GoldFin coil protection, TU1 copper tubing, fresh air intake capability, and a built-in condensate pump with float switch (20.9\" lift). This cassette configuration also includes refrigerant leakage detection and self-diagnosis support.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"hvx-desc-card\"\u003e\n\u003ch2 class=\"hvx-section-title\"\u003eHighlights\u003c\/h2\u003e\n\u003cdiv role=\"list\" class=\"hvx-badges\"\u003e\n\u003cspan role=\"listitem\" class=\"hvx-badge\"\u003eConfigurable 9K–12K\u003c\/span\u003e \u003cspan role=\"listitem\" class=\"hvx-badge\"\u003eR454B refrigerant\u003c\/span\u003e \u003cspan role=\"listitem\" class=\"hvx-badge\"\u003e360° airflow panel\u003c\/span\u003e \u003cspan role=\"listitem\" class=\"hvx-badge\"\u003eHumidity sensor\u003c\/span\u003e \u003cspan role=\"listitem\" class=\"hvx-badge\"\u003eLeak detection\u003c\/span\u003e \u003cspan role=\"listitem\" class=\"hvx-badge\"\u003eOutdoor SEER2: 19.5\u003c\/span\u003e \u003cspan role=\"listitem\" class=\"hvx-badge\"\u003eGoldFin protection\u003c\/span\u003e \u003cspan role=\"listitem\" class=\"hvx-badge\"\u003eBuilt-in Smart Kit\u003c\/span\u003e\n\u003c\/div\u003e\n\u003cul style=\"margin: 12px 0 0; padding-left: 18px;\"\u003e\n\u003cli\u003e\n\u003cstrong\u003eAdjust output to demand:\u003c\/strong\u003e configure cassette capacity for your application.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eComfort modes:\u003c\/strong\u003e Sleep Mode, Turbo Operation, multiple fan speeds, anti-cold-air heating behavior.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConvenient controls:\u003c\/strong\u003e C\u0026amp;H app (Smart Kit), remote, and wall thermostat.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWide ambient operation:\u003c\/strong\u003e Regular outdoor heating and cooling ambient down to \u003cstrong\u003e-13°F\u003c\/strong\u003e.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cdiv aria-label=\"At-a-glance\" role=\"list\" class=\"hvx-kv\"\u003e\n\u003cdiv role=\"listitem\"\u003e\n\u003cstrong\u003eIndoor\u003c\/strong\u003eCH-RSH09-12MCT\u003c\/div\u003e\n\u003cdiv role=\"listitem\"\u003e\n\u003cstrong\u003eOutdoor\u003c\/strong\u003eCH-RES09-230VO\u003c\/div\u003e\n\u003cdiv role=\"listitem\"\u003e\n\u003cstrong\u003eLineset\u003c\/strong\u003e1\/4\" liquid · 3\/8\" gas\u003c\/div\u003e\n\u003cdiv role=\"listitem\"\u003e\n\u003cstrong\u003eMax run\u003c\/strong\u003e82 ft\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"hvx-desc-card\"\u003e\n\u003ch2 class=\"hvx-section-title\"\u003eWhat’s Included\u003c\/h2\u003e\n\u003cul style=\"padding-left: 18px; margin: 8px 0;\"\u003e\n\u003cli\u003eIndoor 4-way ceiling cassette: CH-RSH09-12MCT\u003c\/li\u003e\n\u003cli\u003eOutdoor condenser: CH-RES09-230VO (Regular)\u003c\/li\u003e\n\u003cli\u003eBuilt-in Smart Kit for app control\u003c\/li\u003e\n\u003cli\u003eRemote control and wall thermostat\u003c\/li\u003e\n\u003cli\u003eCeiling Cassette Panel\u003c\/li\u003e\n\u003cli\u003eBuilt-in condensate pump with float switch\u003c\/li\u003e\n\u003cli\u003eManufacturer documentation (see Documents \u0026amp; Downloads)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"hvx-desc-card\"\u003e\n\u003ch2 class=\"hvx-section-title\"\u003eIndoor Specs\u003c\/h2\u003e\n\u003cdiv class=\"hvx-table-wrap\"\u003e\n\u003ctable aria-label=\"Indoor unit specifications\" class=\"hvx-table\"\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eSpec\u003c\/th\u003e\n\u003cth\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCH-RSH09-12MCT\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRefrigerant type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eR454B\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated capacity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e12,000 BTU (configurable 9,000–12,000 via dip switch)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower source\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e208–230V, 1Ph, 60Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSEER2\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e22.2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEER2\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e12.5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePiping (liq\/gas)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1\/4\" \/ 3\/8\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNoise (H\/M\/L)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e43.5 \/ 40.5 \/ 27.5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAir flow\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e417.9 \/ 364.9 \/ 306.1 \/ 194.2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (W×H×D)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e22.44 × 22.44 × 9.65\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDrain size\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"hvx-desc-card\"\u003e\n\u003ch2 class=\"hvx-section-title\"\u003eOutdoor Specs\u003c\/h2\u003e\n\u003cdiv class=\"hvx-table-wrap\"\u003e\n\u003ctable aria-label=\"Outdoor unit specifications\" class=\"hvx-table\"\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eSpec\u003c\/th\u003e\n\u003cth\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCH-RES09-230VO\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRefrigerant type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eR454B\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated capacity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e9,000 BTU\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSEER2\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e19.5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEER2\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e12.8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eHSPF2-5 \/ HSPF2-4\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e8.8 \/ 11\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCooling capacity (Min\/Max)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e9,000 (3,100~11,900)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eHeating capacity (Min\/Max)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e10,000 (3,600~14,000)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAmbient temp (Heating)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-13~75\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAmbient temp (Cooling)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-13~122\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMax pipe length\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e82 ft\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMin circuit \/ Max fuse\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e12 \/ 15\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNoise\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e54\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (W×H×D)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e30.12 × 11.93 × 21.85\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNet \/ Gross weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e62.17 \/ 67.68\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"hvx-desc-card\"\u003e\n\u003ch2 class=\"hvx-section-title\"\u003eDocuments \u0026amp; Downloads\u003c\/h2\u003e\n\u003cul style=\"padding-left: 18px; margin: 8px 0;\"\u003e\n\u003cli\u003e\u003ca rel=\"noopener\" href=\"https:\/\/media.cooperandhunter.us\/4674\/CH-RES09-230VO_CH-RSH09MCT.pdf\" class=\"hvx-link\" target=\"_blank\"\u003eSubmittal (PDF) — CH-RES09-230VO + CH-RSH09MCT\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca rel=\"noopener\" href=\"https:\/\/media.cooperandhunter.us\/4684\/CH-RHP12-230VO_CH-RH12MCT.pdf\" class=\"hvx-link\" target=\"_blank\"\u003eSubmittal (PDF) — CH-RHP12-230VO + CH-RH12MCT\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca rel=\"noopener\" href=\"https:\/\/media.cooperandhunter.us\/4118\/Installation-Manual-R454B-Outdoor-units--.pdf\" class=\"hvx-link\" target=\"_blank\"\u003eInstallation Manual (PDF) — R454B Outdoor Units\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca rel=\"noopener\" href=\"https:\/\/media.cooperandhunter.us\/4654\/Installation-manual-R454B-Ceiling-cassette_compressed.pdf\" class=\"hvx-link\" target=\"_blank\"\u003eInstallation Manual (PDF) — R454B Ceiling Cassette\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca rel=\"noopener\" href=\"https:\/\/media.cooperandhunter.us\/4655\/Owners_-manual-R454B-Ceiling-cassette_compressed.pdf\" class=\"hvx-link\" target=\"_blank\"\u003eOwner’s Manual (PDF) — R454B Ceiling Cassette\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca rel=\"noopener\" href=\"https:\/\/media.cooperandhunter.us\/4125\/120N-wire-controller---owners-manual.pdf\" class=\"hvx-link\" target=\"_blank\"\u003e120N Wire Controller Owner’s Manual (PDF)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca rel=\"noopener\" href=\"https:\/\/media.cooperandhunter.us\/3198\/MultiZone-Combination-HYPER.pdf\" class=\"hvx-link\" target=\"_blank\"\u003eMultiZone Combination (PDF) — Hyper\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca rel=\"noopener\" href=\"https:\/\/media.cooperandhunter.us\/3199\/MultiZone-Combination-Regular.pdf\" class=\"hvx-link\" target=\"_blank\"\u003eMultiZone Combination (PDF) — Regular\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003eAHRI Certified (outdoor): 207742317\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"hvx-desc-card\"\u003e\n\u003ch2 class=\"hvx-section-title\"\u003eImportant\u003c\/h2\u003e\n\u003cp style=\"margin: 0; font-size: 14px;\"\u003eSet cassette capacity during installation (ENC1 dip switch) and confirm drain routing and ceiling clearance before startup.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"hvx-desc-card\"\u003e\n\u003ch2 class=\"hvx-section-title\"\u003eFAQs\u003c\/h2\u003e\n\u003cdetails open=\"\" class=\"hvx-faq\"\u003e\n\u003csummary\u003eCan this cassette be used in a 9K application?\u003c\/summary\u003e\n\u003cdiv style=\"margin-top: 8px;\"\u003eYes—this model supports capacity changes (9K–12K) via the ENC1 dip switch.\u003c\/div\u003e\n\u003c\/details\u003e\n\u003cdetails open=\"\" class=\"hvx-faq\"\u003e\n\u003csummary\u003eWhat’s the minimum outdoor ambient for heating with the Regular outdoor?\u003c\/summary\u003e\n\u003cdiv style=\"margin-top: 8px;\"\u003eDown to -13°F.\u003c\/div\u003e\n\u003c\/details\u003e\n\u003cdetails open=\"\" class=\"hvx-faq\"\u003e\n\u003csummary\u003eDoes it include a pump?\u003c\/summary\u003e\n\u003cdiv style=\"margin-top: 8px;\"\u003eYes—built-in condensate pump with float switch (20.9\" lift capability).\u003c\/div\u003e\n\u003c\/details\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e","brand":"Cooper\u0026Hunter","offers":[{"title":"No Installation","offer_id":42690608660523,"sku":"CH-RSH09-12MCT + CH-RES09-230VO","price":1708.0,"currency_code":"USD","in_stock":true},{"title":"16FT","offer_id":42690608693291,"sku":"CH-RSH09-12MCT + CH-RES09-230VO","price":1889.0,"currency_code":"USD","in_stock":true},{"title":"25FT","offer_id":42690608726059,"sku":"CH-RSH09-12MCT + CH-RES09-230VO","price":1935.0,"currency_code":"USD","in_stock":true},{"title":"50FT","offer_id":42690608758827,"sku":"CH-RSH09-12MCT + CH-RES09-230VO","price":2156.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0625\/5647\/1339\/files\/FourWay_Regular_Product_Hero_48_33b3a9f5-7a1c-442f-a881-e51e604eb6c3.png?v=1769199174"},{"product_id":"cooper-hunter-12-000-btu-dip-switch-9k-12k-hyper-pro-single-zone-four-way-ceiling-cassette-w-refrigerant-humidity-sensor-minisplit-heat-pump-system-r454b-230v","title":"Cooper\u0026Hunter 12,000 BTU Dip Switch (9k-12k) Hyper Pro Single Zone Four-Way Ceiling Cassette w\/ Refrigerant \u0026 Humidity Sensor Minisplit Heat Pump System R454B 230V","description":"\u003cstyle\u003e\n    :root{\n      --hvx-golden:#FAA819; --hvx-slate:#262626; --hvx-ivory:#F4F1E6; --hvx-border:#e2e0d5; --hvx-card-bg:#ffffff;\n    }\n    .hvx-desc{background:var(--hvx-ivory); padding:18px; border-radius:18px; font-family:\"Articulat CF\",system-ui,-apple-system,Segoe UI,Roboto,Arial,sans-serif; color:#111;}\n    .hvx-desc-header{background:linear-gradient(120deg,var(--hvx-golden),var(--hvx-slate)); border-radius:16px; padding:16px 16px 14px; color:#fff; margin-bottom:14px;}\n    .hvx-eyebrow{font-size:12px; letter-spacing:.12em; text-transform:uppercase; opacity:.9; margin:0 0 6px;}\n    .hvx-title{font-family:\"Anton\",Impact,Haettenschweiler,\"Arial Narrow Bold\",sans-serif; font-size:26px; line-height:1.05; margin:0;}\n    .hvx-desc-card{background:var(--hvx-card-bg); border:1px solid var(--hvx-border); border-radius:16px; padding:14px; margin:12px 0; box-shadow:0 10px 18px rgba(0,0,0,.06);}\n    .hvx-section-title{margin:0 0 10px; font-size:13px; letter-spacing:.12em; text-transform:uppercase; display:inline-block; padding-bottom:6px; position:relative;}\n    .hvx-section-title:after{content:\"\"; position:absolute; left:0; bottom:0; height:3px; width:100%; border-radius:99px; background:linear-gradient(90deg,var(--hvx-golden),var(--hvx-slate));}\n    .hvx-badges{display:flex; flex-wrap:wrap; gap:8px; margin:6px 0 10px;}\n    .hvx-badge{display:inline-flex; align-items:center; gap:6px; padding:6px 10px; border-radius:999px; border:1px solid var(--hvx-border); background:#fff; font-size:12px; font-weight:600;}\n    .hvx-grid{display:grid; grid-template-columns:repeat(3,minmax(0,1fr)); gap:10px;}\n    .hvx-kv{border:1px solid var(--hvx-border); border-radius:14px; padding:10px; background:#fff;}\n    .hvx-k{font-size:12px; letter-spacing:.08em; text-transform:uppercase; color:#333; margin:0 0 6px;}\n    .hvx-v{font-size:14px; font-weight:700; margin:0;}\n    .hvx-table-wrap{overflow:auto; border-radius:14px; border:1px solid var(--hvx-border); background:#fff;}\n    table.hvx-table{width:100%; border-collapse:collapse; min-width:520px;}\n    .hvx-table th,.hvx-table td{padding:10px 12px; border-bottom:1px solid var(--hvx-border); vertical-align:top; font-size:14px;}\n    .hvx-table th{background:rgba(250,168,25,.12); text-align:left; font-size:12px; letter-spacing:.1em; text-transform:uppercase;}\n    .hvx-table tr:last-child td{border-bottom:none;}\n    .hvx-link{color:#111; text-decoration:none; border-bottom:2px solid rgba(250,168,25,.7);}\n    .hvx-link:hover{border-bottom-color:#111;}\n    .hvx-faq details{border:1px solid var(--hvx-border); border-radius:14px; background:#fff; padding:10px 12px; margin:10px 0;}\n    .hvx-faq summary{cursor:pointer; font-weight:800;}\n    .hvx-muted{color:#333; margin:6px 0 0;}\n    @media (max-width:720px){ .hvx-grid{grid-template-columns:1fr;} .hvx-title{font-size:24px;} }\n  \u003c\/style\u003e\n\u003cdiv class=\"hvx-desc\"\u003e\n\u003cdiv class=\"hvx-desc-header\"\u003e\n\u003cp class=\"hvx-eyebrow\"\u003eSingle Zone • 4-Way Ceiling Cassette • R454B • 208–230V\u003c\/p\u003e\n\u003ch2 class=\"hvx-title\"\u003eCooper\u0026amp;Hunter 12,000 BTU Dip Switch (9k-12k) Hyper Pro Single Zone Four-Way Ceiling Cassette w\/ Refrigerant \u0026amp; Humidity Sensor Minisplit Heat Pump System R454B 230V\u003c\/h2\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"hvx-desc-card\"\u003e\n\u003ch3 class=\"hvx-section-title\"\u003eOverview\u003c\/h3\u003e\n\u003cp class=\"hvx-muted\"\u003eA four-way ceiling cassette setup built for clean air delivery, even airflow, and smart control. The CH-RSH09-12MCT indoor cassette supports capacity selection (9K–12K class) via dip switch, and adds advanced monitoring features. Paired here with the CH-RHP12-230VO Hyper outdoor unit for strong cold-weather performance.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"hvx-desc-card\"\u003e\n\u003ch3 class=\"hvx-section-title\"\u003eHighlights\u003c\/h3\u003e\n\u003cdiv class=\"hvx-badges\"\u003e\n\u003cspan class=\"hvx-badge\"\u003eR454B Refrigerant\u003c\/span\u003e \u003cspan class=\"hvx-badge\"\u003e360° Airflow Panel\u003c\/span\u003e \u003cspan class=\"hvx-badge\"\u003eHumidity + Leak Detection (RSH)\u003c\/span\u003e \u003cspan class=\"hvx-badge\"\u003eGoldFin Coil Coating\u003c\/span\u003e \u003cspan class=\"hvx-badge\"\u003eBuilt-In Condensate Pump\u003c\/span\u003e \u003cspan class=\"hvx-badge\"\u003eSmart Kit Ready\u003c\/span\u003e\n\u003c\/div\u003e\n\u003cul style=\"margin: 0 0 10px; padding-left: 18px;\" class=\"hvx-muted\"\u003e\n\u003cli\u003eOmni-directional airflow with 360° panel for even room coverage.\u003c\/li\u003e\n\u003cli\u003eActivated carbon filtration support for fresher indoor air.\u003c\/li\u003e\n\u003cli\u003eAnti-cold-air heating behavior to reduce uncomfortable drafts.\u003c\/li\u003e\n\u003cli\u003eQuiet built-in pump with float switch (20.9\" lift) for condensate removal.\u003c\/li\u003e\n\u003cli\u003eTurbo operation, sleep mode, and multiple fan speeds for comfort tuning.\u003c\/li\u003e\n\u003cli\u003eHyper outdoor unit supports low-ambient heating down to -22°F.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cdiv class=\"hvx-grid\"\u003e\n\u003cdiv class=\"hvx-kv\"\u003e\n\u003cp class=\"hvx-k\"\u003eIndoor Model\u003c\/p\u003e\n\u003cp class=\"hvx-v\"\u003e\u003ca href=\"https:\/\/hvacsupplies.com\/search?options%5Bprefix%5D=last\u0026amp;q=CH-RSH09-12MCT\" class=\"hvx-link\"\u003eCH-RSH09-12MCT\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"hvx-kv\"\u003e\n\u003cp class=\"hvx-k\"\u003eOutdoor Model\u003c\/p\u003e\n\u003cp class=\"hvx-v\"\u003e\u003ca href=\"https:\/\/hvacsupplies.com\/search?options%5Bprefix%5D=last\u0026amp;q=CH-RHP12-230VO\" class=\"hvx-link\"\u003eCH-RHP12-230VO\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"hvx-kv\"\u003e\n\u003cp class=\"hvx-k\"\u003eLine Set Size\u003c\/p\u003e\n\u003cp class=\"hvx-v\"\u003e1\/4\" Liquid • 3\/8\" Gas\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"hvx-kv\"\u003e\n\u003cp class=\"hvx-k\"\u003ePower\u003c\/p\u003e\n\u003cp class=\"hvx-v\"\u003e208–230V • 1Ph • 60Hz\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"hvx-kv\"\u003e\n\u003cp class=\"hvx-k\"\u003eOutdoor Max Line Length\u003c\/p\u003e\n\u003cp class=\"hvx-v\"\u003e82 ft\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"hvx-kv\"\u003e\n\u003cp class=\"hvx-k\"\u003eLow-Ambient Heating\u003c\/p\u003e\n\u003cp class=\"hvx-v\"\u003eDown to -22°F\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"hvx-desc-card\"\u003e\n\u003ch3 class=\"hvx-section-title\"\u003eWhat’s Included\u003c\/h3\u003e\n\u003cul style=\"margin: 0; padding-left: 18px;\" class=\"hvx-muted\"\u003e\n\u003cli\u003eIndoor 4-way ceiling cassette: CH-RSH09-12MCT\u003c\/li\u003e\n\u003cli\u003eOutdoor condenser: CH-RHP12-230VO (Hyper)\u003c\/li\u003e\n\u003cli\u003eRemote control (indoor control package)\u003c\/li\u003e\n\u003cli\u003eCeiling Cassette Panel\u003c\/li\u003e\n\u003cli\u003eBuilt-in condensate pump with float switch (indoor)\u003c\/li\u003e\n\u003cli\u003eSmart Kit capability for app control (setup required)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"hvx-desc-card\"\u003e\n\u003ch3 class=\"hvx-section-title\"\u003eIndoor Specs (CH-RSH09-12MCT)\u003c\/h3\u003e\n\u003cdiv class=\"hvx-table-wrap\"\u003e\n\u003ctable class=\"hvx-table\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eSpec\u003c\/th\u003e\n\u003cth\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRefrigerant Type\u003c\/td\u003e\n\u003ctd\u003eR454B\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSystem Type\u003c\/td\u003e\n\u003ctd\u003eSingle Zone\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated Capacity\u003c\/td\u003e\n\u003ctd\u003e12,000 BTU class (dip-switch capacity selection model)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower\u003c\/td\u003e\n\u003ctd\u003e208–230V • 1Ph • 60Hz (Voltage Range: 187–253V)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSEER2 \/ EER2\u003c\/td\u003e\n\u003ctd\u003e22.2 \/ 12.5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDehumidification\u003c\/td\u003e\n\u003ctd\u003e3.07 pints\/day\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIndoor Airflow (CFM)\u003c\/td\u003e\n\u003ctd\u003e417.9 \/ 364.9 \/ 306.1 \/ 194.2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNoise (dB(A))\u003c\/td\u003e\n\u003ctd\u003e43.5 \/ 40.5 \/ 27.5 (H\/M\/L)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUnit Dimensions (W×D×H)\u003c\/td\u003e\n\u003ctd\u003e22.44 × 22.44 × 9.65 in\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNet \/ Gross Weight\u003c\/td\u003e\n\u003ctd\u003e35.27 \/ 41.89 lb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRefrigerant Piping\u003c\/td\u003e\n\u003ctd\u003e1\/4\" Liquid • 3\/8\" Gas\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDrain Pipe Diameter\u003c\/td\u003e\n\u003ctd\u003e1\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Range\u003c\/td\u003e\n\u003ctd\u003eCooling: 60–90°F • Heating: 32–86°F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"hvx-desc-card\"\u003e\n\u003ch3 class=\"hvx-section-title\"\u003eOutdoor Specs (CH-RHP12-230VO)\u003c\/h3\u003e\n\u003cdiv class=\"hvx-table-wrap\"\u003e\n\u003ctable class=\"hvx-table\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eSpec\u003c\/th\u003e\n\u003cth\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRefrigerant Type\u003c\/td\u003e\n\u003ctd\u003eR454B\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated Capacity\u003c\/td\u003e\n\u003ctd\u003e12,000 BTU\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCooling Capacity (Min–Max)\u003c\/td\u003e\n\u003ctd\u003e12,000 (3,800–14,600) BTU\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHeating Capacity (Min–Max)\u003c\/td\u003e\n\u003ctd\u003e12,000 (3,800–16,000) BTU\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower\u003c\/td\u003e\n\u003ctd\u003e208–230V • 1Ph • 60Hz (Voltage Range: 187–253V)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHSPF2 (Region IV \/ V)\u003c\/td\u003e\n\u003ctd\u003e10.5 \/ 8.0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCOP\u003c\/td\u003e\n\u003ctd\u003e3.76\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax Pipe Length\u003c\/td\u003e\n\u003ctd\u003e82 ft\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax Height Difference\u003c\/td\u003e\n\u003ctd\u003e49.2 ft\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMinimum Circuit Ampacity\u003c\/td\u003e\n\u003ctd\u003e15 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax Fuse\u003c\/td\u003e\n\u003ctd\u003e15 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutdoor Airflow\u003c\/td\u003e\n\u003ctd\u003e1,470.6 CFM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutdoor Noise\u003c\/td\u003e\n\u003ctd\u003e56 dB(A)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUnit Dimensions (W×D×H)\u003c\/td\u003e\n\u003ctd\u003e31.69 × 12.99 × 21.81 in\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNet \/ Gross Weight\u003c\/td\u003e\n\u003ctd\u003e72.75 \/ 78.70 lb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAmbient Temperature\u003c\/td\u003e\n\u003ctd\u003eCooling: -22–122°F • Heating: -22–75°F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAdditional Charge\u003c\/td\u003e\n\u003ctd\u003e0.16 oz\/ft (1\/4\" liquid line)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"hvx-desc-card\"\u003e\n\u003ch3 class=\"hvx-section-title\"\u003eDocuments \u0026amp; Downloads\u003c\/h3\u003e\n\u003cul style=\"margin: 0; padding-left: 18px;\" class=\"hvx-muted\"\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/media.cooperandhunter.us\/4118\/Installation-Manual-R454B-Outdoor-units--.pdf\" class=\"hvx-link\"\u003eOutdoor Units Installation Manual (R454B)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/media.cooperandhunter.us\/4200\/SlimDuct-Leaflet-R454B.pdf\" class=\"hvx-link\"\u003eSlimDuct Leaflet (R454B)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/media.cooperandhunter.us\/4654\/Installation-manual-R454B-Ceiling-cassette_compressed.pdf\" class=\"hvx-link\"\u003eCeiling Cassette Installation Manual (R454B)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/media.cooperandhunter.us\/4655\/Owners_-manual-R454B-Ceiling-cassette_compressed.pdf\" class=\"hvx-link\"\u003eCeiling Cassette Owner’s Manual (R454B)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/media.cooperandhunter.us\/4125\/120N-wire-controller---owners-manual.pdf\" class=\"hvx-link\"\u003e120N Wire Controller Owner’s Manual\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/media.cooperandhunter.us\/3198\/MultiZone-Combination-HYPER.pdf\" class=\"hvx-link\"\u003eMultiZone Combination Guide — Hyper\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/media.cooperandhunter.us\/3199\/MultiZone-Combination-Regular.pdf\" class=\"hvx-link\"\u003eMultiZone Combination Guide — Regular\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/media.cooperandhunter.us\/4170\/CH-RHP12-230VO-%2B-CH-RH12MASTWM-230VI.pdf\" class=\"hvx-link\"\u003eSubmittal Sheet: CH-RHP12-230VO + CH-RH12MASTWM-230VI\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/media.cooperandhunter.us\/4203\/CH-RHP12-230VO-%2B-CH-RS06-12MDT--MS.pdf\" class=\"hvx-link\"\u003eSubmittal Sheet: CH-RHP12-230VO + CH-RS06-12MDT\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"hvx-desc-card\"\u003e\n\u003ch3 class=\"hvx-section-title\"\u003eImportant\u003c\/h3\u003e\n\u003cul style=\"margin: 0; padding-left: 18px;\" class=\"hvx-muted\"\u003e\n\u003cli\u003eProfessional installation is recommended.\u003c\/li\u003e\n\u003cli\u003eVerify electrical requirements: 208–230V dedicated circuit sized per nameplate\/MCA.\u003c\/li\u003e\n\u003cli\u003eUse correct line set sizing: 1\/4\" liquid and 3\/8\" suction.\u003c\/li\u003e\n\u003cli\u003eFor help choosing equipment, contact us: \u003ca href=\"https:\/\/hvacsupplies.com\/pages\/contact\" class=\"hvx-link\"\u003ehvacsupplies.com\/pages\/contact\u003c\/a\u003e • \u003ca href=\"tel:+18005438933\" class=\"hvx-link\"\u003e(800) 543-8933\u003c\/a\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"hvx-desc-card hvx-faq\"\u003e\n\u003ch3 class=\"hvx-section-title\"\u003eFAQs\u003c\/h3\u003e\n\u003cdetails open=\"\"\u003e\n\u003csummary\u003eDoes this cassette include a condensate pump?\u003c\/summary\u003e\n\u003cp class=\"hvx-muted\"\u003eYes. The indoor cassette includes a built-in pump with float switch (20.9\" lift).\u003c\/p\u003e\n\u003c\/details\u003e\n\u003cdetails open=\"\"\u003e\n\u003csummary\u003eCan I control it with an app?\u003c\/summary\u003e\n\u003cp class=\"hvx-muted\"\u003eSmart Kit capability supports app control through the C\u0026amp;H platform after setup.\u003c\/p\u003e\n\u003c\/details\u003e\n\u003cdetails open=\"\"\u003e\n\u003csummary\u003eWhat line set sizes are required?\u003c\/summary\u003e\n\u003cp class=\"hvx-muted\"\u003eThis cassette uses 1\/4\" liquid and 3\/8\" gas piping.\u003c\/p\u003e\n\u003c\/details\u003e\n\u003cdetails open=\"\"\u003e\n\u003csummary\u003eHow does the Hyper outdoor unit handle cold weather?\u003c\/summary\u003e\n\u003cp class=\"hvx-muted\"\u003eThe CH-RHP12-230VO supports heating operation down to -22°F ambient.\u003c\/p\u003e\n\u003c\/details\u003e\n\u003cdetails open=\"\"\u003e\n\u003csummary\u003eIs a wall thermostat required?\u003c\/summary\u003e\n\u003cp class=\"hvx-muted\"\u003eNo. The system supports remote control operation; wall thermostat options may be added if desired.\u003c\/p\u003e\n\u003c\/details\u003e\n\u003cdetails open=\"\"\u003e\n\u003csummary\u003eIs this single-zone only?\u003c\/summary\u003e\n\u003cp class=\"hvx-muted\"\u003eThis configuration is presented as single-zone pairing.\u003c\/p\u003e\n\u003c\/details\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e","brand":"Cooper\u0026Hunter","offers":[{"title":"No Installation","offer_id":42690630516779,"sku":"CH-RSH09-12MCT + CH-RHP12-230VO","price":2028.0,"currency_code":"USD","in_stock":true},{"title":"16FT","offer_id":42690630549547,"sku":"CH-RSH09-12MCT + CH-RHP12-230VO","price":2210.0,"currency_code":"USD","in_stock":true},{"title":"25FT","offer_id":42690630582315,"sku":"CH-RSH09-12MCT + CH-RHP12-230VO","price":2256.0,"currency_code":"USD","in_stock":true},{"title":"50FT","offer_id":42690630615083,"sku":"CH-RSH09-12MCT + CH-RHP12-230VO","price":2476.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0625\/5647\/1339\/files\/2-ZoneDuctlessMiniSplitAC_HeatPump48000BTU_26.png?v=1769199192"},{"product_id":"cooper-hunter-12-000-btu-dip-switch-9k-12k-pro-single-zone-four-way-ceiling-cassette-w-refrigerant-humidity-sensor-minisplit-heat-pump-system-r454b-230v","title":"Cooper\u0026Hunter 12,000 BTU Dip Switch (9k-12k) Pro Single Zone Four-Way Ceiling Cassette w\/ Refrigerant \u0026 Humidity Sensor Minisplit Heat Pump System R454B 230V","description":"\u003cstyle\u003e\n    :root{--hvx-golden:#FAA819; --hvx-slate:#262626; --hvx-ivory:#F4F1E6; --hvx-border:#e2e0d5; --hvx-card-bg:#ffffff;}\n    .hvx-desc{background:var(--hvx-ivory); padding:18px; border-radius:18px; font-family:\"Articulat CF\",system-ui,-apple-system,Segoe UI,Roboto,Arial,sans-serif; color:#111;}\n    .hvx-desc-header{background:linear-gradient(120deg,var(--hvx-golden),var(--hvx-slate)); border-radius:16px; padding:16px 16px 14px; color:#fff; margin-bottom:14px;}\n    .hvx-eyebrow{font-size:12px; letter-spacing:.12em; text-transform:uppercase; opacity:.9; margin:0 0 6px;}\n    .hvx-title{font-family:\"Anton\",Impact,Haettenschweiler,\"Arial Narrow Bold\",sans-serif; font-size:26px; line-height:1.05; margin:0;}\n    .hvx-desc-card{background:var(--hvx-card-bg); border:1px solid var(--hvx-border); border-radius:16px; padding:14px; margin:12px 0; box-shadow:0 10px 18px rgba(0,0,0,.06);}\n    .hvx-section-title{margin:0 0 10px; font-size:13px; letter-spacing:.12em; text-transform:uppercase; display:inline-block; padding-bottom:6px; position:relative;}\n    .hvx-section-title:after{content:\"\"; position:absolute; left:0; bottom:0; height:3px; width:100%; border-radius:99px; background:linear-gradient(90deg,var(--hvx-golden),var(--hvx-slate));}\n    .hvx-badges{display:flex; flex-wrap:wrap; gap:8px; margin:6px 0 10px;}\n    .hvx-badge{display:inline-flex; align-items:center; gap:6px; padding:6px 10px; border-radius:999px; border:1px solid var(--hvx-border); background:#fff; font-size:12px; font-weight:600;}\n    .hvx-grid{display:grid; grid-template-columns:repeat(3,minmax(0,1fr)); gap:10px;}\n    .hvx-kv{border:1px solid var(--hvx-border); border-radius:14px; padding:10px; background:#fff;}\n    .hvx-k{font-size:12px; letter-spacing:.08em; text-transform:uppercase; color:#333; margin:0 0 6px;}\n    .hvx-v{font-size:14px; font-weight:700; margin:0;}\n    .hvx-table-wrap{overflow:auto; border-radius:14px; border:1px solid var(--hvx-border); background:#fff;}\n    table.hvx-table{width:100%; border-collapse:collapse; min-width:520px;}\n    .hvx-table th,.hvx-table td{padding:10px 12px; border-bottom:1px solid var(--hvx-border); vertical-align:top; font-size:14px;}\n    .hvx-table th{background:rgba(250,168,25,.12); text-align:left; font-size:12px; letter-spacing:.1em; text-transform:uppercase;}\n    .hvx-table tr:last-child td{border-bottom:none;}\n    .hvx-link{color:#111; text-decoration:none; border-bottom:2px solid rgba(250,168,25,.7);}\n    .hvx-link:hover{border-bottom-color:#111;}\n    .hvx-faq details{border:1px solid var(--hvx-border); border-radius:14px; background:#fff; padding:10px 12px; margin:10px 0;}\n    .hvx-faq summary{cursor:pointer; font-weight:800;}\n    .hvx-muted{color:#333; margin:6px 0 0;}\n    @media (max-width:720px){ .hvx-grid{grid-template-columns:1fr;} .hvx-title{font-size:24px;} }\n  \u003c\/style\u003e\n\u003cdiv class=\"hvx-desc\"\u003e\n\u003cdiv class=\"hvx-desc-header\"\u003e\n\u003cp class=\"hvx-eyebrow\"\u003eSingle Zone • 4-Way Ceiling Cassette • R454B • 208–230V\u003c\/p\u003e\n\u003ch2 class=\"hvx-title\"\u003eCooper\u0026amp;Hunter 12,000 BTU Dip Switch (9k-12k) Pro Single Zone Four-Way Ceiling Cassette w\/ Refrigerant \u0026amp; Humidity Sensor Minisplit Heat Pump System R454B 230V\u003c\/h2\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"hvx-desc-card\"\u003e\n\u003ch3 class=\"hvx-section-title\"\u003eOverview\u003c\/h3\u003e\n\u003cp class=\"hvx-muted\"\u003eA four-way ceiling cassette configuration designed for strong airflow distribution, clean-air support, and smart control options. The CH-RSH09-12MCT indoor cassette supports dip-switch capacity selection (9K–12K class) and adds advanced monitoring features. Paired here with the CH-RES12-230VO regular outdoor unit for efficient, dependable heating and cooling.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"hvx-desc-card\"\u003e\n\u003ch3 class=\"hvx-section-title\"\u003eHighlights\u003c\/h3\u003e\n\u003cdiv class=\"hvx-badges\"\u003e\n\u003cspan class=\"hvx-badge\"\u003eR454B Refrigerant\u003c\/span\u003e \u003cspan class=\"hvx-badge\"\u003e360° Airflow Panel\u003c\/span\u003e \u003cspan class=\"hvx-badge\"\u003eHumidity + Leak Detection (RSH)\u003c\/span\u003e \u003cspan class=\"hvx-badge\"\u003eGoldFin Coil Coating\u003c\/span\u003e \u003cspan class=\"hvx-badge\"\u003eBuilt-In Condensate Pump\u003c\/span\u003e \u003cspan class=\"hvx-badge\"\u003eInverter Outdoor\u003c\/span\u003e\n\u003c\/div\u003e\n\u003cul class=\"hvx-muted\" style=\"margin: 0 0 10px; padding-left: 18px;\"\u003e\n\u003cli\u003eOmni-directional airflow with 360° panel for even room coverage.\u003c\/li\u003e\n\u003cli\u003eActivated carbon filtration support for fresher indoor air.\u003c\/li\u003e\n\u003cli\u003eAnti-cold-air heating behavior to reduce drafts.\u003c\/li\u003e\n\u003cli\u003eQuiet built-in pump with float switch (20.9\" lift) for condensate removal.\u003c\/li\u003e\n\u003cli\u003eTurbo operation, sleep mode, and multiple fan speeds.\u003c\/li\u003e\n\u003cli\u003eRegular outdoor unit supports low-ambient heating down to -13°F.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cdiv class=\"hvx-grid\"\u003e\n\u003cdiv class=\"hvx-kv\"\u003e\n\u003cp class=\"hvx-k\"\u003eIndoor Model\u003c\/p\u003e\n\u003cp class=\"hvx-v\"\u003e\u003ca class=\"hvx-link\" href=\"https:\/\/hvacsupplies.com\/search?options%5Bprefix%5D=last\u0026amp;q=CH-RSH09-12MCT\"\u003eCH-RSH09-12MCT\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"hvx-kv\"\u003e\n\u003cp class=\"hvx-k\"\u003eOutdoor Model\u003c\/p\u003e\n\u003cp class=\"hvx-v\"\u003e\u003ca class=\"hvx-link\" href=\"https:\/\/hvacsupplies.com\/search?options%5Bprefix%5D=last\u0026amp;q=CH-RES12-230VO\"\u003eCH-RES12-230VO\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"hvx-kv\"\u003e\n\u003cp class=\"hvx-k\"\u003eLine Set Size\u003c\/p\u003e\n\u003cp class=\"hvx-v\"\u003e1\/4\" Liquid • 3\/8\" Gas\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"hvx-kv\"\u003e\n\u003cp class=\"hvx-k\"\u003eSEER2\u003c\/p\u003e\n\u003cp class=\"hvx-v\"\u003e21.1\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"hvx-kv\"\u003e\n\u003cp class=\"hvx-k\"\u003eOutdoor Max Line Length\u003c\/p\u003e\n\u003cp class=\"hvx-v\"\u003e82 ft\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"hvx-kv\"\u003e\n\u003cp class=\"hvx-k\"\u003eLow-Ambient Heating\u003c\/p\u003e\n\u003cp class=\"hvx-v\"\u003eDown to -13°F\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"hvx-desc-card\"\u003e\n\u003ch3 class=\"hvx-section-title\"\u003eWhat’s Included\u003c\/h3\u003e\n\u003cul class=\"hvx-muted\" style=\"margin: 0; padding-left: 18px;\"\u003e\n\u003cli\u003eIndoor 4-way ceiling cassette: CH-RSH09-12MCT\u003c\/li\u003e\n\u003cli\u003eOutdoor condenser: CH-RES12-230VO (Regular)\u003c\/li\u003e\n\u003cli\u003eRemote control (indoor control package)\u003c\/li\u003e\n\u003cli\u003eCeiling Cassette Panel\u003c\/li\u003e\n\u003cli\u003eBuilt-in condensate pump with float switch (indoor)\u003c\/li\u003e\n\u003cli\u003eSmart Kit capability for app control (setup required)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"hvx-desc-card\"\u003e\n\u003ch3 class=\"hvx-section-title\"\u003eIndoor Specs (CH-RSH09-12MCT)\u003c\/h3\u003e\n\u003cdiv class=\"hvx-table-wrap\"\u003e\n\u003ctable class=\"hvx-table\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eSpec\u003c\/th\u003e\n\u003cth\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRefrigerant Type\u003c\/td\u003e\n\u003ctd\u003eR454B\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSystem Type\u003c\/td\u003e\n\u003ctd\u003eSingle Zone\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated Capacity\u003c\/td\u003e\n\u003ctd\u003e12,000 BTU class (dip-switch capacity selection model)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower\u003c\/td\u003e\n\u003ctd\u003e208–230V • 1Ph • 60Hz (Voltage Range: 187–253V)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSEER2 \/ EER2\u003c\/td\u003e\n\u003ctd\u003e22.2 \/ 12.5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDehumidification\u003c\/td\u003e\n\u003ctd\u003e3.07 pints\/day\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIndoor Airflow (CFM)\u003c\/td\u003e\n\u003ctd\u003e417.9 \/ 364.9 \/ 306.1 \/ 194.2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNoise (dB(A))\u003c\/td\u003e\n\u003ctd\u003e43.5 \/ 40.5 \/ 27.5 (H\/M\/L)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUnit Dimensions (W×D×H)\u003c\/td\u003e\n\u003ctd\u003e22.44 × 22.44 × 9.65 in\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNet \/ Gross Weight\u003c\/td\u003e\n\u003ctd\u003e35.27 \/ 41.89 lb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRefrigerant Piping\u003c\/td\u003e\n\u003ctd\u003e1\/4\" Liquid • 3\/8\" Gas\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDrain Pipe Diameter\u003c\/td\u003e\n\u003ctd\u003e1\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Range\u003c\/td\u003e\n\u003ctd\u003eCooling: 60–90°F • Heating: 32–86°F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"hvx-desc-card\"\u003e\n\u003ch3 class=\"hvx-section-title\"\u003eOutdoor Specs (CH-RES12-230VO)\u003c\/h3\u003e\n\u003cdiv class=\"hvx-table-wrap\"\u003e\n\u003ctable class=\"hvx-table\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eSpec\u003c\/th\u003e\n\u003cth\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRefrigerant Type\u003c\/td\u003e\n\u003ctd\u003eR454B\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated Capacity\u003c\/td\u003e\n\u003ctd\u003e12,000 BTU\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCooling Capacity (Min–Max)\u003c\/td\u003e\n\u003ctd\u003e11,500 (3,100–13,000) BTU\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHeating Capacity (Min–Max)\u003c\/td\u003e\n\u003ctd\u003e12,000 (3,700–15,600) BTU\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower\u003c\/td\u003e\n\u003ctd\u003e208–230V • 1Ph • 60Hz (Voltage Range: 187–253V)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSEER2 \/ EER2\u003c\/td\u003e\n\u003ctd\u003e19 \/ 11.7\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHSPF2 (Region IV \/ V)\u003c\/td\u003e\n\u003ctd\u003e10.2 \/ 8.0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCOP\u003c\/td\u003e\n\u003ctd\u003e3.42\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax Pipe Length\u003c\/td\u003e\n\u003ctd\u003e82 ft\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax Height Difference\u003c\/td\u003e\n\u003ctd\u003e49.2 ft\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMinimum Circuit Ampacity\u003c\/td\u003e\n\u003ctd\u003e12 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax Fuse\u003c\/td\u003e\n\u003ctd\u003e15 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutdoor Airflow\u003c\/td\u003e\n\u003ctd\u003e1,236.1 CFM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutdoor Noise\u003c\/td\u003e\n\u003ctd\u003e55.5 dB(A)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUnit Dimensions (W×D×H)\u003c\/td\u003e\n\u003ctd\u003e30.12 × 11.93 × 21.85 in\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNet \/ Gross Weight\u003c\/td\u003e\n\u003ctd\u003e62.17 \/ 67.68 lb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAmbient Temperature\u003c\/td\u003e\n\u003ctd\u003eCooling: -13–122°F • Heating: -13–75°F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAdditional Charge\u003c\/td\u003e\n\u003ctd\u003e0.16 oz\/ft (1\/4\" liquid line)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"hvx-desc-card\"\u003e\n\u003ch3 class=\"hvx-section-title\"\u003eDocuments \u0026amp; Downloads\u003c\/h3\u003e\n\u003cul class=\"hvx-muted\" style=\"margin: 0; padding-left: 18px;\"\u003e\n\u003cli\u003e\u003ca class=\"hvx-link\" href=\"https:\/\/media.cooperandhunter.us\/4118\/Installation-Manual-R454B-Outdoor-units--.pdf\"\u003eOutdoor Units Installation Manual (R454B)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca class=\"hvx-link\" href=\"https:\/\/media.cooperandhunter.us\/4200\/SlimDuct-Leaflet-R454B.pdf\"\u003eSlimDuct Leaflet (R454B)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca class=\"hvx-link\" href=\"https:\/\/media.cooperandhunter.us\/4654\/Installation-manual-R454B-Ceiling-cassette_compressed.pdf\"\u003eCeiling Cassette Installation Manual (R454B)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca class=\"hvx-link\" href=\"https:\/\/media.cooperandhunter.us\/4655\/Owners_-manual-R454B-Ceiling-cassette_compressed.pdf\"\u003eCeiling Cassette Owner’s Manual (R454B)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca class=\"hvx-link\" href=\"https:\/\/media.cooperandhunter.us\/4125\/120N-wire-controller---owners-manual.pdf\"\u003e120N Wire Controller Owner’s Manual\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca class=\"hvx-link\" href=\"https:\/\/media.cooperandhunter.us\/3198\/MultiZone-Combination-HYPER.pdf\"\u003eMultiZone Combination Guide — Hyper\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca class=\"hvx-link\" href=\"https:\/\/media.cooperandhunter.us\/3199\/MultiZone-Combination-Regular.pdf\"\u003eMultiZone Combination Guide — Regular\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca class=\"hvx-link\" href=\"https:\/\/media.cooperandhunter.us\/4156\/CH-RES12-230VO-%2B-CH-PRO12MASTWM-230VI.pdf\"\u003eSubmittal Sheet: CH-RES12-230VO + CH-PRO12MASTWM-230VI\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca class=\"hvx-link\" href=\"https:\/\/media.cooperandhunter.us\/4169\/CH-RES12-230VO-%2B-CH-RH12MASTWM-230VI.pdf\"\u003eSubmittal Sheet: CH-RES12-230VO + CH-RH12MASTWM-230VI\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca class=\"hvx-link\" href=\"https:\/\/media.cooperandhunter.us\/4210\/CH-RES12-230VO-%2B-CH-RS06-12MDT--MS.pdf\"\u003eSubmittal Sheet: CH-RES12-230VO + CH-RS06-12MDT\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca class=\"hvx-link\" href=\"https:\/\/media.cooperandhunter.us\/4677\/CH-RES12-230VO_CH-RSH12MCT.pdf\"\u003eSubmittal Sheet: CH-RES12-230VO + CH-RSH12MCT\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca class=\"hvx-link\" href=\"https:\/\/media.cooperandhunter.us\/4676\/CH-RES12-230VO_CH-RH12MCT.pdf\"\u003eSubmittal Sheet: CH-RES12-230VO + CH-RH12MCT\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"hvx-desc-card\"\u003e\n\u003ch3 class=\"hvx-section-title\"\u003eImportant\u003c\/h3\u003e\n\u003cul class=\"hvx-muted\" style=\"margin: 0; padding-left: 18px;\"\u003e\n\u003cli\u003eProfessional installation is recommended.\u003c\/li\u003e\n\u003cli\u003eVerify electrical requirements: 208–230V dedicated circuit sized per nameplate\/MCA.\u003c\/li\u003e\n\u003cli\u003eUse correct line set sizing: 1\/4\" liquid and 3\/8\" suction.\u003c\/li\u003e\n\u003cli\u003eFor help choosing equipment, contact us: \u003ca class=\"hvx-link\" href=\"https:\/\/hvacsupplies.com\/pages\/contact\"\u003ehvacsupplies.com\/pages\/contact\u003c\/a\u003e • \u003ca class=\"hvx-link\" href=\"tel:+18005438933\"\u003e(800) 543-8933\u003c\/a\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"hvx-desc-card hvx-faq\"\u003e\n\u003ch3 class=\"hvx-section-title\"\u003eFAQs\u003c\/h3\u003e\n\u003cdetails\u003e\n\u003csummary\u003eDoes this cassette include a condensate pump?\u003c\/summary\u003e\n\u003cp class=\"hvx-muted\"\u003eYes. The indoor cassette includes a built-in pump with float switch (20.9\" lift).\u003c\/p\u003e\n\u003c\/details\u003e\n\u003cdetails\u003e\n\u003csummary\u003eWhat line set sizes are required?\u003c\/summary\u003e\n\u003cp class=\"hvx-muted\"\u003eThis cassette uses 1\/4\" liquid and 3\/8\" gas piping.\u003c\/p\u003e\n\u003c\/details\u003e\n\u003cdetails\u003e\n\u003csummary\u003eHow cold can the regular outdoor unit operate in heating?\u003c\/summary\u003e\n\u003cp class=\"hvx-muted\"\u003eThe CH-RES12-230VO supports heating operation down to -13°F ambient.\u003c\/p\u003e\n\u003c\/details\u003e\n\u003cdetails\u003e\n\u003csummary\u003eCan I control it with an app?\u003c\/summary\u003e\n\u003cp class=\"hvx-muted\"\u003eSmart Kit capability supports app control through the C\u0026amp;H platform after setup.\u003c\/p\u003e\n\u003c\/details\u003e\n\u003cdetails\u003e\n\u003csummary\u003eIs a wall thermostat required?\u003c\/summary\u003e\n\u003cp class=\"hvx-muted\"\u003eNo. The system supports remote control operation; wall thermostat options may be added if desired.\u003c\/p\u003e\n\u003c\/details\u003e\n\u003cdetails\u003e\n\u003csummary\u003eIs this single-zone only?\u003c\/summary\u003e\n\u003cp class=\"hvx-muted\"\u003eThis configuration is presented as single-zone pairing.\u003c\/p\u003e\n\u003c\/details\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e","brand":"Cooper\u0026Hunter","offers":[{"title":"No Installation","offer_id":42690661875755,"sku":"CH-RSH09-12MCT + CH-RES12-230VO","price":1752.0,"currency_code":"USD","in_stock":true},{"title":"16FT","offer_id":42690661908523,"sku":"CH-RSH09-12MCT + CH-RES12-230VO","price":1934.0,"currency_code":"USD","in_stock":true},{"title":"25FT","offer_id":42690661941291,"sku":"CH-RSH09-12MCT + CH-RES12-230VO","price":1980.0,"currency_code":"USD","in_stock":true},{"title":"50FT","offer_id":42690661974059,"sku":"CH-RSH09-12MCT + CH-RES12-230VO","price":2200.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0625\/5647\/1339\/files\/FourWay_Regular_Product_Hero_48_33b3a9f5-7a1c-442f-a881-e51e604eb6c3.png?v=1769199174"},{"product_id":"cooper-hunter-12-000-btu-hyper-single-zone-four-way-ceiling-cassette-w-humidity-sensor-minisplit-heat-pump-system-r454b-230v","title":"Cooper\u0026Hunter 12,000 BTU Hyper Single Zone Four-Way Ceiling Cassette w\/ Humidity Sensor Minisplit Heat Pump System R454B 230V","description":"\u003cstyle\u003e\n    :root{--hvx-golden:#FAA819; --hvx-slate:#262626; --hvx-ivory:#F4F1E6; --hvx-border:#e2e0d5; --hvx-card-bg:#ffffff;}\n    .hvx-desc{background:var(--hvx-ivory); padding:18px; border-radius:18px; font-family:\"Articulat CF\",system-ui,-apple-system,Segoe UI,Roboto,Arial,sans-serif; color:#111;}\n    .hvx-desc-header{background:linear-gradient(120deg,var(--hvx-golden),var(--hvx-slate)); border-radius:16px; padding:16px 16px 14px; color:#fff; margin-bottom:14px;}\n    .hvx-eyebrow{font-size:12px; letter-spacing:.12em; text-transform:uppercase; opacity:.9; margin:0 0 6px;}\n    .hvx-title{font-family:\"Anton\",Impact,Haettenschweiler,\"Arial Narrow Bold\",sans-serif; font-size:26px; line-height:1.05; margin:0;}\n    .hvx-desc-card{background:var(--hvx-card-bg); border:1px solid var(--hvx-border); border-radius:16px; padding:14px; margin:12px 0; box-shadow:0 10px 18px rgba(0,0,0,.06);}\n    .hvx-section-title{margin:0 0 10px; font-size:13px; letter-spacing:.12em; text-transform:uppercase; display:inline-block; padding-bottom:6px; position:relative;}\n    .hvx-section-title:after{content:\"\"; position:absolute; left:0; bottom:0; height:3px; width:100%; border-radius:99px; background:linear-gradient(90deg,var(--hvx-golden),var(--hvx-slate));}\n    .hvx-badges{display:flex; flex-wrap:wrap; gap:8px; margin:6px 0 10px;}\n    .hvx-badge{display:inline-flex; align-items:center; gap:6px; padding:6px 10px; border-radius:999px; border:1px solid var(--hvx-border); background:#fff; font-size:12px; font-weight:600;}\n    .hvx-grid{display:grid; grid-template-columns:repeat(3,minmax(0,1fr)); gap:10px;}\n    .hvx-kv{border:1px solid var(--hvx-border); border-radius:14px; padding:10px; background:#fff;}\n    .hvx-k{font-size:12px; letter-spacing:.08em; text-transform:uppercase; color:#333; margin:0 0 6px;}\n    .hvx-v{font-size:14px; font-weight:700; margin:0;}\n    .hvx-table-wrap{overflow:auto; border-radius:14px; border:1px solid var(--hvx-border); background:#fff;}\n    table.hvx-table{width:100%; border-collapse:collapse; min-width:520px;}\n    .hvx-table th,.hvx-table td{padding:10px 12px; border-bottom:1px solid var(--hvx-border); vertical-align:top; font-size:14px;}\n    .hvx-table th{background:rgba(250,168,25,.12); text-align:left; font-size:12px; letter-spacing:.1em; text-transform:uppercase;}\n    .hvx-table tr:last-child td{border-bottom:none;}\n    .hvx-link{color:#111; text-decoration:none; border-bottom:2px solid rgba(250,168,25,.7);}\n    .hvx-link:hover{border-bottom-color:#111;}\n    .hvx-faq details{border:1px solid var(--hvx-border); border-radius:14px; background:#fff; padding:10px 12px; margin:10px 0;}\n    .hvx-faq summary{cursor:pointer; font-weight:800;}\n    .hvx-muted{color:#333; margin:6px 0 0;}\n    @media (max-width:720px){ .hvx-grid{grid-template-columns:1fr;} .hvx-title{font-size:24px;} }\n  \u003c\/style\u003e\n\u003cdiv class=\"hvx-desc\"\u003e\n\u003cdiv class=\"hvx-desc-header\"\u003e\n\u003cp class=\"hvx-eyebrow\"\u003eSingle Zone • 4-Way Ceiling Cassette • R454B • 208–230V\u003c\/p\u003e\n\u003ch2 class=\"hvx-title\"\u003eCooper\u0026amp;Hunter 12,000 BTU Hyper Single Zone Four-Way Ceiling Cassette w\/ Humidity Sensor Minisplit Heat Pump System R454B 230V\u003c\/h2\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"hvx-desc-card\"\u003e\n\u003ch3 class=\"hvx-section-title\"\u003eOverview\u003c\/h3\u003e\n\u003cp class=\"hvx-muted\"\u003eA 12K-class four-way ceiling cassette pairing built for even airflow, clean-air support, and convenient control. The CH-RH12MCT indoor cassette uses a 360° air flow panel and omni-directional delivery to cover the entire space. Paired here with the CH-RHP12-230VO Hyper outdoor unit for strong cold-weather heating down to -22°F.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"hvx-desc-card\"\u003e\n\u003ch3 class=\"hvx-section-title\"\u003eHighlights\u003c\/h3\u003e\n\u003cdiv class=\"hvx-badges\"\u003e\n\u003cspan class=\"hvx-badge\"\u003eR454B Refrigerant\u003c\/span\u003e \u003cspan class=\"hvx-badge\"\u003e360° Airflow Panel\u003c\/span\u003e \u003cspan class=\"hvx-badge\"\u003eHumidity Sensor\u003c\/span\u003e \u003cspan class=\"hvx-badge\"\u003eGoldFin Coil Coating\u003c\/span\u003e \u003cspan class=\"hvx-badge\"\u003eBuilt-In Condensate Pump\u003c\/span\u003e \u003cspan class=\"hvx-badge\"\u003eHyper Heating Outdoor\u003c\/span\u003e\n\u003c\/div\u003e\n\u003cul class=\"hvx-muted\" style=\"margin: 0 0 10px; padding-left: 18px;\"\u003e\n\u003cli\u003eOmni-directional airflow with 360° panel for even room coverage.\u003c\/li\u003e\n\u003cli\u003eActivated carbon filtration support for fresher indoor air.\u003c\/li\u003e\n\u003cli\u003eAnti-cold-air heating behavior to reduce drafts.\u003c\/li\u003e\n\u003cli\u003eQuiet built-in pump with float switch (20.9\" lift) for condensate removal.\u003c\/li\u003e\n\u003cli\u003eTurbo operation, sleep mode, and multiple fan speeds.\u003c\/li\u003e\n\u003cli\u003eHyper outdoor unit supports low-ambient heating down to -22°F.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cdiv class=\"hvx-grid\"\u003e\n\u003cdiv class=\"hvx-kv\"\u003e\n\u003cp class=\"hvx-k\"\u003eIndoor Model\u003c\/p\u003e\n\u003cp class=\"hvx-v\"\u003e\u003ca class=\"hvx-link\" href=\"https:\/\/hvacsupplies.com\/search?options%5Bprefix%5D=last\u0026amp;q=CH-RH12MCT\"\u003eCH-RH12MCT\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"hvx-kv\"\u003e\n\u003cp class=\"hvx-k\"\u003eOutdoor Model\u003c\/p\u003e\n\u003cp class=\"hvx-v\"\u003e\u003ca class=\"hvx-link\" href=\"https:\/\/hvacsupplies.com\/search?options%5Bprefix%5D=last\u0026amp;q=CH-RHP12-230VO\"\u003eCH-RHP12-230VO\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"hvx-kv\"\u003e\n\u003cp class=\"hvx-k\"\u003eLine Set Size\u003c\/p\u003e\n\u003cp class=\"hvx-v\"\u003e1\/4\" Liquid • 3\/8\" Gas\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"hvx-kv\"\u003e\n\u003cp class=\"hvx-k\"\u003eSEER2\u003c\/p\u003e\n\u003cp class=\"hvx-v\"\u003e22.2\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"hvx-kv\"\u003e\n\u003cp class=\"hvx-k\"\u003eOutdoor Max Line Length\u003c\/p\u003e\n\u003cp class=\"hvx-v\"\u003e82 ft\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"hvx-kv\"\u003e\n\u003cp class=\"hvx-k\"\u003eLow-Ambient Heating\u003c\/p\u003e\n\u003cp class=\"hvx-v\"\u003eDown to -22°F\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"hvx-desc-card\"\u003e\n\u003ch3 class=\"hvx-section-title\"\u003eWhat’s Included\u003c\/h3\u003e\n\u003cul class=\"hvx-muted\" style=\"margin: 0; padding-left: 18px;\"\u003e\n\u003cli\u003eIndoor 4-way ceiling cassette: CH-RH12MCT\u003c\/li\u003e\n\u003cli\u003eOutdoor condenser: CH-RHP12-230VO (Hyper)\u003c\/li\u003e\n\u003cli\u003eRemote control (indoor control package)\u003c\/li\u003e\n\u003cli\u003eCeiling Cassette Panel\u003c\/li\u003e\n\u003cli\u003eBuilt-in condensate pump with float switch (indoor)\u003c\/li\u003e\n\u003cli\u003eSmart Kit capability for app control (setup required)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"hvx-desc-card\"\u003e\n\u003ch3 class=\"hvx-section-title\"\u003eIndoor Specs (CH-RH12MCT)\u003c\/h3\u003e\n\u003cdiv class=\"hvx-table-wrap\"\u003e\n\u003ctable class=\"hvx-table\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eSpec\u003c\/th\u003e\n\u003cth\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRefrigerant Type\u003c\/td\u003e\n\u003ctd\u003eR454B\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSystem Type\u003c\/td\u003e\n\u003ctd\u003eSingle Zone\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBTU Rated\u003c\/td\u003e\n\u003ctd\u003e12,000\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower\u003c\/td\u003e\n\u003ctd\u003e208–230V • 1Ph • 60Hz (Voltage Range: 187–253V)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSEER2 \/ EER2\u003c\/td\u003e\n\u003ctd\u003e22.2 \/ 12.5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDehumidification\u003c\/td\u003e\n\u003ctd\u003e3.07 pints\/day\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIndoor Airflow (CFM)\u003c\/td\u003e\n\u003ctd\u003e417.9 \/ 364.9 \/ 306.1 \/ 194.2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNoise (dB(A))\u003c\/td\u003e\n\u003ctd\u003e43.5 \/ 40.5 \/ 27.5 (H\/M\/L)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUnit Dimensions (W×D×H)\u003c\/td\u003e\n\u003ctd\u003e22.44 × 22.44 × 9.65 in\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNet \/ Gross Weight\u003c\/td\u003e\n\u003ctd\u003e35.27 \/ 41.89 lb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRefrigerant Piping\u003c\/td\u003e\n\u003ctd\u003e1\/4\" Liquid • 3\/8\" Gas\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDrain Pipe Diameter\u003c\/td\u003e\n\u003ctd\u003e1\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Range\u003c\/td\u003e\n\u003ctd\u003eCooling: 60–90°F • Heating: 32–86°F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"hvx-desc-card\"\u003e\n\u003ch3 class=\"hvx-section-title\"\u003eOutdoor Specs (CH-RHP12-230VO)\u003c\/h3\u003e\n\u003cdiv class=\"hvx-table-wrap\"\u003e\n\u003ctable class=\"hvx-table\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eSpec\u003c\/th\u003e\n\u003cth\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRefrigerant Type\u003c\/td\u003e\n\u003ctd\u003eR454B\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated Capacity\u003c\/td\u003e\n\u003ctd\u003e12,000 BTU\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCooling Capacity (Min–Max)\u003c\/td\u003e\n\u003ctd\u003e12,000 (3,800–14,600) BTU\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHeating Capacity (Min–Max)\u003c\/td\u003e\n\u003ctd\u003e12,000 (3,800–16,000) BTU\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower\u003c\/td\u003e\n\u003ctd\u003e208–230V • 1Ph • 60Hz (Voltage Range: 187–253V)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHSPF2 (Region IV \/ V)\u003c\/td\u003e\n\u003ctd\u003e10.5 \/ 8.0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCOP\u003c\/td\u003e\n\u003ctd\u003e3.76\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax Pipe Length\u003c\/td\u003e\n\u003ctd\u003e82 ft\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax Height Difference\u003c\/td\u003e\n\u003ctd\u003e49.2 ft\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMinimum Circuit Ampacity\u003c\/td\u003e\n\u003ctd\u003e15 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax Fuse\u003c\/td\u003e\n\u003ctd\u003e15 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutdoor Airflow\u003c\/td\u003e\n\u003ctd\u003e1,470.6 CFM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutdoor Noise\u003c\/td\u003e\n\u003ctd\u003e56 dB(A)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUnit Dimensions (W×D×H)\u003c\/td\u003e\n\u003ctd\u003e31.69 × 12.99 × 21.81 in\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNet \/ Gross Weight\u003c\/td\u003e\n\u003ctd\u003e72.75 \/ 78.70 lb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAmbient Temperature\u003c\/td\u003e\n\u003ctd\u003eCooling: -22–122°F • Heating: -22–75°F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAdditional Charge\u003c\/td\u003e\n\u003ctd\u003e0.16 oz\/ft (1\/4\" liquid line)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"hvx-desc-card\"\u003e\n\u003ch3 class=\"hvx-section-title\"\u003eDocuments \u0026amp; Downloads\u003c\/h3\u003e\n\u003cul class=\"hvx-muted\" style=\"margin: 0; padding-left: 18px;\"\u003e\n\u003cli\u003e\u003ca class=\"hvx-link\" href=\"https:\/\/media.cooperandhunter.us\/4684\/CH-RHP12-230VO_CH-RH12MCT.pdf\"\u003eSubmittal Sheet: CH-RHP12-230VO + CH-RH12MCT\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca class=\"hvx-link\" href=\"https:\/\/media.cooperandhunter.us\/4118\/Installation-Manual-R454B-Outdoor-units--.pdf\"\u003eOutdoor Units Installation Manual (R454B)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca class=\"hvx-link\" href=\"https:\/\/media.cooperandhunter.us\/4200\/SlimDuct-Leaflet-R454B.pdf\"\u003eSlimDuct Leaflet (R454B)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca class=\"hvx-link\" href=\"https:\/\/media.cooperandhunter.us\/4654\/Installation-manual-R454B-Ceiling-cassette_compressed.pdf\"\u003eCeiling Cassette Installation Manual (R454B)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca class=\"hvx-link\" href=\"https:\/\/media.cooperandhunter.us\/4655\/Owners_-manual-R454B-Ceiling-cassette_compressed.pdf\"\u003eCeiling Cassette Owner’s Manual (R454B)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca class=\"hvx-link\" href=\"https:\/\/media.cooperandhunter.us\/4028\/120N-wire-controller---owners-manual.pdf\"\u003e120N Wire Controller Owner’s Manual\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca class=\"hvx-link\" href=\"https:\/\/media.cooperandhunter.us\/3198\/MultiZone-Combination-HYPER.pdf\"\u003eMultiZone Combination Guide — Hyper\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca class=\"hvx-link\" href=\"https:\/\/media.cooperandhunter.us\/3199\/MultiZone-Combination-Regular.pdf\"\u003eMultiZone Combination Guide — Regular\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca class=\"hvx-link\" href=\"https:\/\/media.cooperandhunter.us\/4170\/CH-RHP12-230VO-%2B-CH-RH12MASTWM-230VI.pdf\"\u003eSubmittal Sheet: CH-RHP12-230VO + CH-RH12MASTWM-230VI\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca class=\"hvx-link\" href=\"https:\/\/media.cooperandhunter.us\/4203\/CH-RHP12-230VO-%2B-CH-RS06-12MDT--MS.pdf\"\u003eSubmittal Sheet: CH-RHP12-230VO + CH-RS06-12MDT\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"hvx-desc-card\"\u003e\n\u003ch3 class=\"hvx-section-title\"\u003eImportant\u003c\/h3\u003e\n\u003cul class=\"hvx-muted\" style=\"margin: 0; padding-left: 18px;\"\u003e\n\u003cli\u003eProfessional installation is recommended.\u003c\/li\u003e\n\u003cli\u003eVerify electrical requirements: 208–230V dedicated circuit sized per nameplate\/MCA.\u003c\/li\u003e\n\u003cli\u003eUse correct line set sizing: 1\/4\" liquid and 3\/8\" suction.\u003c\/li\u003e\n\u003cli\u003eFor help choosing equipment, contact us: \u003ca class=\"hvx-link\" href=\"https:\/\/hvacsupplies.com\/pages\/contact\"\u003ehvacsupplies.com\/pages\/contact\u003c\/a\u003e • \u003ca class=\"hvx-link\" href=\"tel:+18005438933\"\u003e(800) 543-8933\u003c\/a\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"hvx-desc-card hvx-faq\"\u003e\n\u003ch3 class=\"hvx-section-title\"\u003eFAQs\u003c\/h3\u003e\n\u003cdetails\u003e\n\u003csummary\u003eDoes this cassette include a condensate pump?\u003c\/summary\u003e\n\u003cp class=\"hvx-muted\"\u003eYes. The indoor cassette includes a built-in pump with float switch (20.9\" lift).\u003c\/p\u003e\n\u003c\/details\u003e\n\u003cdetails\u003e\n\u003csummary\u003eWhat line set sizes are required?\u003c\/summary\u003e\n\u003cp class=\"hvx-muted\"\u003eThis cassette uses 1\/4\" liquid and 3\/8\" gas piping.\u003c\/p\u003e\n\u003c\/details\u003e\n\u003cdetails\u003e\n\u003csummary\u003eHow does the Hyper outdoor unit handle cold weather?\u003c\/summary\u003e\n\u003cp class=\"hvx-muted\"\u003eThe CH-RHP12-230VO supports heating operation down to -22°F ambient.\u003c\/p\u003e\n\u003c\/details\u003e\n\u003cdetails\u003e\n\u003csummary\u003eCan I control it with an app?\u003c\/summary\u003e\n\u003cp class=\"hvx-muted\"\u003eSmart Kit capability supports app control through the C\u0026amp;H platform after setup.\u003c\/p\u003e\n\u003c\/details\u003e\n\u003cdetails\u003e\n\u003csummary\u003eIs a wall thermostat required?\u003c\/summary\u003e\n\u003cp class=\"hvx-muted\"\u003eNo. The system supports remote control operation; wall thermostat options may be added if desired.\u003c\/p\u003e\n\u003c\/details\u003e\n\u003cdetails\u003e\n\u003csummary\u003eIs this single-zone only?\u003c\/summary\u003e\n\u003cp class=\"hvx-muted\"\u003eThis configuration is presented as single-zone pairing.\u003c\/p\u003e\n\u003c\/details\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e","brand":"Cooper\u0026Hunter","offers":[{"title":"No Installation","offer_id":42690672492587,"sku":"CH-RH12MCT + CH-RHP12-230VO","price":1948.0,"currency_code":"USD","in_stock":true},{"title":"16FT","offer_id":42690672525355,"sku":"CH-RH12MCT + CH-RHP12-230VO","price":2130.0,"currency_code":"USD","in_stock":true},{"title":"25FT","offer_id":42690672558123,"sku":"CH-RH12MCT + CH-RHP12-230VO","price":2176.0,"currency_code":"USD","in_stock":true},{"title":"50FT","offer_id":42690672590891,"sku":"CH-RH12MCT + CH-RHP12-230VO","price":2396.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0625\/5647\/1339\/files\/2-ZoneDuctlessMiniSplitAC_HeatPump48000BTU_26.png?v=1769199192"},{"product_id":"cooper-hunter-12-000-btu-single-zone-four-way-ceiling-cassette-w-humidity-sensor-minisplit-heat-pump-system-r454b-230v","title":"Cooper\u0026Hunter 12,000 BTU Single Zone Four-Way Ceiling Cassette w\/ Humidity Sensor Minisplit Heat Pump System R454B 230V","description":"\u003cstyle\u003e\n    :root{--hvx-golden:#FAA819; --hvx-slate:#262626; --hvx-ivory:#F4F1E6; --hvx-border:#e2e0d5; --hvx-card-bg:#ffffff;}\n    .hvx-desc{background:var(--hvx-ivory); padding:18px; border-radius:18px; font-family:\"Articulat CF\",system-ui,-apple-system,Segoe UI,Roboto,Arial,sans-serif; color:#111;}\n    .hvx-desc-header{background:linear-gradient(120deg,var(--hvx-golden),var(--hvx-slate)); border-radius:16px; padding:16px 16px 14px; color:#fff; margin-bottom:14px;}\n    .hvx-eyebrow{font-size:12px; letter-spacing:.12em; text-transform:uppercase; opacity:.9; margin:0 0 6px;}\n    .hvx-title{font-family:\"Anton\",Impact,Haettenschweiler,\"Arial Narrow Bold\",sans-serif; font-size:26px; line-height:1.05; margin:0;}\n    .hvx-desc-card{background:var(--hvx-card-bg); border:1px solid var(--hvx-border); border-radius:16px; padding:14px; margin:12px 0; box-shadow:0 10px 18px rgba(0,0,0,.06);}\n    .hvx-section-title{margin:0 0 10px; font-size:13px; letter-spacing:.12em; text-transform:uppercase; display:inline-block; padding-bottom:6px; position:relative;}\n    .hvx-section-title:after{content:\"\"; position:absolute; left:0; bottom:0; height:3px; width:100%; border-radius:99px; background:linear-gradient(90deg,var(--hvx-golden),var(--hvx-slate));}\n    .hvx-badges{display:flex; flex-wrap:wrap; gap:8px; margin:6px 0 10px;}\n    .hvx-badge{display:inline-flex; align-items:center; gap:6px; padding:6px 10px; border-radius:999px; border:1px solid var(--hvx-border); background:#fff; font-size:12px; font-weight:600;}\n    .hvx-grid{display:grid; grid-template-columns:repeat(3,minmax(0,1fr)); gap:10px;}\n    .hvx-kv{border:1px solid var(--hvx-border); border-radius:14px; padding:10px; background:#fff;}\n    .hvx-k{font-size:12px; letter-spacing:.08em; text-transform:uppercase; color:#333; margin:0 0 6px;}\n    .hvx-v{font-size:14px; font-weight:700; margin:0;}\n    .hvx-table-wrap{overflow:auto; border-radius:14px; border:1px solid var(--hvx-border); background:#fff;}\n    table.hvx-table{width:100%; border-collapse:collapse; min-width:520px;}\n    .hvx-table th,.hvx-table td{padding:10px 12px; border-bottom:1px solid var(--hvx-border); vertical-align:top; font-size:14px;}\n    .hvx-table th{background:rgba(250,168,25,.12); text-align:left; font-size:12px; letter-spacing:.1em; text-transform:uppercase;}\n    .hvx-table tr:last-child td{border-bottom:none;}\n    .hvx-link{color:#111; text-decoration:none; border-bottom:2px solid rgba(250,168,25,.7);}\n    .hvx-link:hover{border-bottom-color:#111;}\n    .hvx-faq details{border:1px solid var(--hvx-border); border-radius:14px; background:#fff; padding:10px 12px; margin:10px 0;}\n    .hvx-faq summary{cursor:pointer; font-weight:800;}\n    .hvx-muted{color:#333; margin:6px 0 0;}\n    @media (max-width:720px){ .hvx-grid{grid-template-columns:1fr;} .hvx-title{font-size:24px;} }\n  \u003c\/style\u003e\n\u003cdiv class=\"hvx-desc\"\u003e\n\u003cdiv class=\"hvx-desc-header\"\u003e\n\u003cp class=\"hvx-eyebrow\"\u003eSingle Zone • 4-Way Ceiling Cassette • R454B • 208–230V\u003c\/p\u003e\n\u003ch2 class=\"hvx-title\"\u003eCooper\u0026amp;Hunter 12,000 BTU Single Zone Four-Way Ceiling Cassette w\/ Humidity Sensor Minisplit Heat Pump System R454B 230V\u003c\/h2\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"hvx-desc-card\"\u003e\n\u003ch3 class=\"hvx-section-title\"\u003eOverview\u003c\/h3\u003e\n\u003cp class=\"hvx-muted\"\u003eA balanced 12K-class ceiling cassette pairing designed for even airflow, clean-air support, and efficient inverter operation. The CH-RH12MCT cassette delivers omni-directional comfort through a 360° air flow panel, while the CH-RES12-230VO outdoor unit provides dependable heating and cooling with strong efficiency.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"hvx-desc-card\"\u003e\n\u003ch3 class=\"hvx-section-title\"\u003eHighlights\u003c\/h3\u003e\n\u003cdiv class=\"hvx-badges\"\u003e\n\u003cspan class=\"hvx-badge\"\u003eR454B Refrigerant\u003c\/span\u003e \u003cspan class=\"hvx-badge\"\u003e360° Airflow Panel\u003c\/span\u003e \u003cspan class=\"hvx-badge\"\u003eHumidity Sensor\u003c\/span\u003e \u003cspan class=\"hvx-badge\"\u003eGoldFin Coil Coating\u003c\/span\u003e \u003cspan class=\"hvx-badge\"\u003eBuilt-In Condensate Pump\u003c\/span\u003e \u003cspan class=\"hvx-badge\"\u003eInverter Outdoor\u003c\/span\u003e\n\u003c\/div\u003e\n\u003cul style=\"margin: 0 0 10px; padding-left: 18px;\" class=\"hvx-muted\"\u003e\n\u003cli\u003eOmni-directional airflow with 360° panel for even room coverage.\u003c\/li\u003e\n\u003cli\u003eActivated carbon filtration support for fresher indoor air.\u003c\/li\u003e\n\u003cli\u003eAnti-cold-air heating behavior to reduce drafts.\u003c\/li\u003e\n\u003cli\u003eQuiet built-in pump with float switch (20.9\" lift) for condensate removal.\u003c\/li\u003e\n\u003cli\u003eTurbo operation, sleep mode, and multiple fan speeds.\u003c\/li\u003e\n\u003cli\u003eRegular outdoor unit supports low-ambient heating down to -13°F.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cdiv class=\"hvx-grid\"\u003e\n\u003cdiv class=\"hvx-kv\"\u003e\n\u003cp class=\"hvx-k\"\u003eIndoor Model\u003c\/p\u003e\n\u003cp class=\"hvx-v\"\u003e\u003ca href=\"https:\/\/hvacsupplies.com\/search?options%5Bprefix%5D=last\u0026amp;q=CH-RH12MCT\" class=\"hvx-link\"\u003eCH-RH12MCT\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"hvx-kv\"\u003e\n\u003cp class=\"hvx-k\"\u003eOutdoor Model\u003c\/p\u003e\n\u003cp class=\"hvx-v\"\u003e\u003ca href=\"https:\/\/hvacsupplies.com\/search?options%5Bprefix%5D=last\u0026amp;q=CH-RES12-230VO\" class=\"hvx-link\"\u003eCH-RES12-230VO\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"hvx-kv\"\u003e\n\u003cp class=\"hvx-k\"\u003eLine Set Size\u003c\/p\u003e\n\u003cp class=\"hvx-v\"\u003e1\/4\" Liquid • 3\/8\" Gas\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"hvx-kv\"\u003e\n\u003cp class=\"hvx-k\"\u003eSEER2\u003c\/p\u003e\n\u003cp class=\"hvx-v\"\u003e21.1\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"hvx-kv\"\u003e\n\u003cp class=\"hvx-k\"\u003eOutdoor Max Line Length\u003c\/p\u003e\n\u003cp class=\"hvx-v\"\u003e82 ft\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"hvx-kv\"\u003e\n\u003cp class=\"hvx-k\"\u003eLow-Ambient Heating\u003c\/p\u003e\n\u003cp class=\"hvx-v\"\u003eDown to -13°F\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"hvx-desc-card\"\u003e\n\u003ch3 class=\"hvx-section-title\"\u003eWhat’s Included\u003c\/h3\u003e\n\u003cul style=\"margin: 0; padding-left: 18px;\" class=\"hvx-muted\"\u003e\n\u003cli\u003eIndoor 4-way ceiling cassette: CH-RH12MCT\u003c\/li\u003e\n\u003cli\u003eOutdoor condenser: CH-RES12-230VO (Regular)\u003c\/li\u003e\n\u003cli\u003eRemote control (indoor control package)\u003c\/li\u003e\n\u003cli\u003eCeiling Cassette Panel\u003c\/li\u003e\n\u003cli\u003eBuilt-in condensate pump with float switch (indoor)\u003c\/li\u003e\n\u003cli\u003eSmart Kit capability for app control (setup required)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"hvx-desc-card\"\u003e\n\u003ch3 class=\"hvx-section-title\"\u003eIndoor Specs (CH-RH12MCT)\u003c\/h3\u003e\n\u003cdiv class=\"hvx-table-wrap\"\u003e\n\u003ctable class=\"hvx-table\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eSpec\u003c\/th\u003e\n\u003cth\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRefrigerant Type\u003c\/td\u003e\n\u003ctd\u003eR454B\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSystem Type\u003c\/td\u003e\n\u003ctd\u003eSingle Zone\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBTU Rated\u003c\/td\u003e\n\u003ctd\u003e12,000\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower\u003c\/td\u003e\n\u003ctd\u003e208–230V • 1Ph • 60Hz (Voltage Range: 187–253V)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSEER2 \/ EER2\u003c\/td\u003e\n\u003ctd\u003e22.2 \/ 12.5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDehumidification\u003c\/td\u003e\n\u003ctd\u003e3.07 pints\/day\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIndoor Airflow (CFM)\u003c\/td\u003e\n\u003ctd\u003e417.9 \/ 364.9 \/ 306.1 \/ 194.2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNoise (dB(A))\u003c\/td\u003e\n\u003ctd\u003e43.5 \/ 40.5 \/ 27.5 (H\/M\/L)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUnit Dimensions (W×D×H)\u003c\/td\u003e\n\u003ctd\u003e22.44 × 22.44 × 9.65 in\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNet \/ Gross Weight\u003c\/td\u003e\n\u003ctd\u003e35.27 \/ 41.89 lb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRefrigerant Piping\u003c\/td\u003e\n\u003ctd\u003e1\/4\" Liquid • 3\/8\" Gas\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDrain Pipe Diameter\u003c\/td\u003e\n\u003ctd\u003e1\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Range\u003c\/td\u003e\n\u003ctd\u003eCooling: 60–90°F • Heating: 32–86°F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"hvx-desc-card\"\u003e\n\u003ch3 class=\"hvx-section-title\"\u003eOutdoor Specs (CH-RES12-230VO)\u003c\/h3\u003e\n\u003cdiv class=\"hvx-table-wrap\"\u003e\n\u003ctable class=\"hvx-table\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eSpec\u003c\/th\u003e\n\u003cth\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRefrigerant Type\u003c\/td\u003e\n\u003ctd\u003eR454B\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated Capacity\u003c\/td\u003e\n\u003ctd\u003e12,000 BTU\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCooling Capacity (Min–Max)\u003c\/td\u003e\n\u003ctd\u003e11,500 (3,100–13,000) BTU\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHeating Capacity (Min–Max)\u003c\/td\u003e\n\u003ctd\u003e12,000 (3,700–15,600) BTU\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower\u003c\/td\u003e\n\u003ctd\u003e208–230V • 1Ph • 60Hz (Voltage Range: 187–253V)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSEER2 \/ EER2\u003c\/td\u003e\n\u003ctd\u003e19 \/ 11.7\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHSPF2 (Region IV \/ V)\u003c\/td\u003e\n\u003ctd\u003e10.2 \/ 8.0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCOP\u003c\/td\u003e\n\u003ctd\u003e3.42\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax Pipe Length\u003c\/td\u003e\n\u003ctd\u003e82 ft\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax Height Difference\u003c\/td\u003e\n\u003ctd\u003e49.2 ft\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMinimum Circuit Ampacity\u003c\/td\u003e\n\u003ctd\u003e12 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax Fuse\u003c\/td\u003e\n\u003ctd\u003e15 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutdoor Airflow\u003c\/td\u003e\n\u003ctd\u003e1,236.1 CFM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutdoor Noise\u003c\/td\u003e\n\u003ctd\u003e55.5 dB(A)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUnit Dimensions (W×D×H)\u003c\/td\u003e\n\u003ctd\u003e30.12 × 11.93 × 21.85 in\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNet \/ Gross Weight\u003c\/td\u003e\n\u003ctd\u003e62.17 \/ 67.68 lb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAmbient Temperature\u003c\/td\u003e\n\u003ctd\u003eCooling: -13–122°F • Heating: -13–75°F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAdditional Charge\u003c\/td\u003e\n\u003ctd\u003e0.16 oz\/ft (1\/4\" liquid line)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"hvx-desc-card\"\u003e\n\u003ch3 class=\"hvx-section-title\"\u003eDocuments \u0026amp; Downloads\u003c\/h3\u003e\n\u003cul style=\"margin: 0; padding-left: 18px;\" class=\"hvx-muted\"\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/media.cooperandhunter.us\/4676\/CH-RES12-230VO_CH-RH12MCT.pdf\" class=\"hvx-link\"\u003eSubmittal Sheet: CH-RES12-230VO + CH-RH12MCT\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/media.cooperandhunter.us\/4118\/Installation-Manual-R454B-Outdoor-units--.pdf\" class=\"hvx-link\"\u003eOutdoor Units Installation Manual (R454B)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/media.cooperandhunter.us\/4200\/SlimDuct-Leaflet-R454B.pdf\" class=\"hvx-link\"\u003eSlimDuct Leaflet (R454B)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/media.cooperandhunter.us\/4654\/Installation-manual-R454B-Ceiling-cassette_compressed.pdf\" class=\"hvx-link\"\u003eCeiling Cassette Installation Manual (R454B)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/media.cooperandhunter.us\/4655\/Owners_-manual-R454B-Ceiling-cassette_compressed.pdf\" class=\"hvx-link\"\u003eCeiling Cassette Owner’s Manual (R454B)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/media.cooperandhunter.us\/4028\/120N-wire-controller---owners-manual.pdf\" class=\"hvx-link\"\u003e120N Wire Controller Owner’s Manual\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/media.cooperandhunter.us\/3198\/MultiZone-Combination-HYPER.pdf\" class=\"hvx-link\"\u003eMultiZone Combination Guide — Hyper\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/media.cooperandhunter.us\/3199\/MultiZone-Combination-Regular.pdf\" class=\"hvx-link\"\u003eMultiZone Combination Guide — Regular\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/media.cooperandhunter.us\/4156\/CH-RES12-230VO-%2B-CH-PRO12MASTWM-230VI.pdf\" class=\"hvx-link\"\u003eSubmittal Sheet: CH-RES12-230VO + CH-PRO12MASTWM-230VI\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/media.cooperandhunter.us\/4169\/CH-RES12-230VO-%2B-CH-RH12MASTWM-230VI.pdf\" class=\"hvx-link\"\u003eSubmittal Sheet: CH-RES12-230VO + CH-RH12MASTWM-230VI\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/media.cooperandhunter.us\/4210\/CH-RES12-230VO-%2B-CH-RS06-12MDT--MS.pdf\" class=\"hvx-link\"\u003eSubmittal Sheet: CH-RES12-230VO + CH-RS06-12MDT\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/media.cooperandhunter.us\/4677\/CH-RES12-230VO_CH-RSH12MCT.pdf\" class=\"hvx-link\"\u003eSubmittal Sheet: CH-RES12-230VO + CH-RSH12MCT\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"hvx-desc-card\"\u003e\n\u003ch3 class=\"hvx-section-title\"\u003eImportant\u003c\/h3\u003e\n\u003cul style=\"margin: 0; padding-left: 18px;\" class=\"hvx-muted\"\u003e\n\u003cli\u003eProfessional installation is recommended.\u003c\/li\u003e\n\u003cli\u003eVerify electrical requirements: 208–230V dedicated circuit sized per nameplate\/MCA.\u003c\/li\u003e\n\u003cli\u003eUse correct line set sizing: 1\/4\" liquid and 3\/8\" suction.\u003c\/li\u003e\n\u003cli\u003eFor help choosing equipment, contact us: \u003ca href=\"https:\/\/hvacsupplies.com\/pages\/contact\" class=\"hvx-link\"\u003ehvacsupplies.com\/pages\/contact\u003c\/a\u003e • \u003ca href=\"tel:+18005438933\" class=\"hvx-link\"\u003e(800) 543-8933\u003c\/a\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"hvx-desc-card hvx-faq\"\u003e\n\u003ch3 class=\"hvx-section-title\"\u003eFAQs\u003c\/h3\u003e\n\u003cdetails\u003e\n\u003csummary\u003eDoes this cassette include a condensate pump?\u003c\/summary\u003e\n\u003cp class=\"hvx-muted\"\u003eYes. The indoor cassette includes a built-in pump with float switch (20.9\" lift).\u003c\/p\u003e\n\u003c\/details\u003e\n\u003cdetails\u003e\n\u003csummary\u003eWhat line set sizes are required?\u003c\/summary\u003e\n\u003cp class=\"hvx-muted\"\u003eThis cassette uses 1\/4\" liquid and 3\/8\" gas piping.\u003c\/p\u003e\n\u003c\/details\u003e\n\u003cdetails\u003e\n\u003csummary\u003eHow cold can the regular outdoor unit operate in heating?\u003c\/summary\u003e\n\u003cp class=\"hvx-muted\"\u003eThe CH-RES12-230VO supports heating operation down to -13°F ambient.\u003c\/p\u003e\n\u003c\/details\u003e\n\u003cdetails\u003e\n\u003csummary\u003eCan I control it with an app?\u003c\/summary\u003e\n\u003cp class=\"hvx-muted\"\u003eSmart Kit capability supports app control through the C\u0026amp;H platform after setup.\u003c\/p\u003e\n\u003c\/details\u003e\n\u003cdetails\u003e\n\u003csummary\u003eIs a wall thermostat required?\u003c\/summary\u003e\n\u003cp class=\"hvx-muted\"\u003eNo. The system supports remote control operation; wall thermostat options may be added if desired.\u003c\/p\u003e\n\u003c\/details\u003e\n\u003cdetails\u003e\n\u003csummary\u003eIs this single-zone only?\u003c\/summary\u003e\n\u003cp class=\"hvx-muted\"\u003eThis configuration is presented as single-zone pairing.\u003c\/p\u003e\n\u003c\/details\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e","brand":"Cooper\u0026Hunter","offers":[{"title":"No Installation","offer_id":42690705358891,"sku":"CH-RH12MCT + CH-RES12-230VO","price":1678.0,"currency_code":"USD","in_stock":true},{"title":"16FT","offer_id":42690705391659,"sku":"CH-RH12MCT + CH-RES12-230VO","price":1859.0,"currency_code":"USD","in_stock":true},{"title":"25FT","offer_id":42690705424427,"sku":"CH-RH12MCT + CH-RES12-230VO","price":1905.0,"currency_code":"USD","in_stock":true},{"title":"50FT","offer_id":42690705457195,"sku":"CH-RH12MCT + CH-RES12-230VO","price":2125.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0625\/5647\/1339\/files\/FourWay_Regular_Product_Hero_48_33b3a9f5-7a1c-442f-a881-e51e604eb6c3.png?v=1769199174"},{"product_id":"cooper-hunter-18-000-btu-hyper-pro-single-zone-four-way-ceiling-cassette-w-refrigerant-humidity-sensor-minisplit-heat-pump-system-r454b-230v","title":"Cooper\u0026Hunter 18,000 BTU Hyper Pro Single Zone Four-Way Ceiling Cassette w\/ Refrigerant \u0026 Humidity Sensor Minisplit Heat Pump System R454B 230V","description":"\u003cstyle\u003e\n    :root{--hvx-golden:#FAA819; --hvx-slate:#262626; --hvx-ivory:#F4F1E6; --hvx-border:#e2e0d5; --hvx-card-bg:#ffffff;}\n    .hvx-desc{background:var(--hvx-ivory); padding:18px; border-radius:18px; font-family:\"Articulat CF\",system-ui,-apple-system,Segoe UI,Roboto,Arial,sans-serif; color:#111;}\n    .hvx-desc-header{background:linear-gradient(120deg,var(--hvx-golden),var(--hvx-slate)); border-radius:16px; padding:16px 16px 14px; color:#fff; margin-bottom:14px;}\n    .hvx-eyebrow{font-size:12px; letter-spacing:.12em; text-transform:uppercase; opacity:.9; margin:0 0 6px;}\n    .hvx-title{font-family:\"Anton\",Impact,Haettenschweiler,\"Arial Narrow Bold\",sans-serif; font-size:26px; line-height:1.05; margin:0;}\n    .hvx-desc-card{background:var(--hvx-card-bg); border:1px solid var(--hvx-border); border-radius:16px; padding:14px; margin:12px 0; box-shadow:0 10px 18px rgba(0,0,0,.06);}\n    .hvx-section-title{margin:0 0 10px; font-size:13px; letter-spacing:.12em; text-transform:uppercase; display:inline-block; padding-bottom:6px; position:relative;}\n    .hvx-section-title:after{content:\"\"; position:absolute; left:0; bottom:0; height:3px; width:100%; border-radius:99px; background:linear-gradient(90deg,var(--hvx-golden),var(--hvx-slate));}\n    .hvx-badges{display:flex; flex-wrap:wrap; gap:8px; margin:6px 0 10px;}\n    .hvx-badge{display:inline-flex; align-items:center; gap:6px; padding:6px 10px; border-radius:999px; border:1px solid var(--hvx-border); background:#fff; font-size:12px; font-weight:600;}\n    .hvx-grid{display:grid; grid-template-columns:repeat(3,minmax(0,1fr)); gap:10px;}\n    .hvx-kv{border:1px solid var(--hvx-border); border-radius:14px; padding:10px; background:#fff;}\n    .hvx-k{font-size:12px; letter-spacing:.08em; text-transform:uppercase; color:#333; margin:0 0 6px;}\n    .hvx-v{font-size:14px; font-weight:700; margin:0;}\n    .hvx-table-wrap{overflow:auto; border-radius:14px; border:1px solid var(--hvx-border); background:#fff;}\n    table.hvx-table{width:100%; border-collapse:collapse; min-width:520px;}\n    .hvx-table th,.hvx-table td{padding:10px 12px; border-bottom:1px solid var(--hvx-border); vertical-align:top; font-size:14px;}\n    .hvx-table th{background:rgba(250,168,25,.12); text-align:left; font-size:12px; letter-spacing:.1em; text-transform:uppercase;}\n    .hvx-table tr:last-child td{border-bottom:none;}\n    .hvx-link{color:#111; text-decoration:none; border-bottom:2px solid rgba(250,168,25,.7);}\n    .hvx-link:hover{border-bottom-color:#111;}\n    .hvx-faq details{border:1px solid var(--hvx-border); border-radius:14px; background:#fff; padding:10px 12px; margin:10px 0;}\n    .hvx-faq summary{cursor:pointer; font-weight:800;}\n    .hvx-muted{color:#333; margin:6px 0 0;}\n    @media (max-width:720px){ .hvx-grid{grid-template-columns:1fr;} .hvx-title{font-size:24px;} }\n  \u003c\/style\u003e\n\u003cdiv class=\"hvx-desc\"\u003e\n\u003cdiv class=\"hvx-desc-header\"\u003e\n\u003cp class=\"hvx-eyebrow\"\u003eSingle Zone • 4-Way Ceiling Cassette • R454B • 208–230V\u003c\/p\u003e\n\u003ch2 class=\"hvx-title\"\u003eCooper\u0026amp;Hunter 18,000 BTU Hyper Pro Single Zone Four-Way Ceiling Cassette w\/ Refrigerant \u0026amp; Humidity Sensor Minisplit Heat Pump System R454B 230V\u003c\/h2\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"hvx-desc-card\"\u003e\n\u003ch3 class=\"hvx-section-title\"\u003eOverview\u003c\/h3\u003e\n\u003cp class=\"hvx-muted\"\u003eAn 18K four-way ceiling cassette pairing designed for even airflow distribution, clean-air support, and added diagnostic protection. The CH-RSH18MCT cassette includes refrigerant leakage detection in addition to humidity sensing and self-diagnosis features. Paired with the CH-RHP18-230VO Hyper outdoor unit for strong cold-weather heating down to -22°F.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"hvx-desc-card\"\u003e\n\u003ch3 class=\"hvx-section-title\"\u003eHighlights\u003c\/h3\u003e\n\u003cdiv class=\"hvx-badges\"\u003e\n\u003cspan class=\"hvx-badge\"\u003eR454B Refrigerant\u003c\/span\u003e \u003cspan class=\"hvx-badge\"\u003e360° Airflow Panel\u003c\/span\u003e \u003cspan class=\"hvx-badge\"\u003eLeak Detection (RSH)\u003c\/span\u003e \u003cspan class=\"hvx-badge\"\u003eHumidity Sensor\u003c\/span\u003e \u003cspan class=\"hvx-badge\"\u003eGoldFin Coil Coating\u003c\/span\u003e \u003cspan class=\"hvx-badge\"\u003eBuilt-In Condensate Pump\u003c\/span\u003e\n\u003c\/div\u003e\n\u003cul style=\"margin: 0 0 10px; padding-left: 18px;\" class=\"hvx-muted\"\u003e\n\u003cli\u003eOmni-directional airflow and 360° panel helps distribute air evenly throughout the room.\u003c\/li\u003e\n\u003cli\u003eActivated carbon filtration support for fresher indoor air.\u003c\/li\u003e\n\u003cli\u003eRefrigerant leakage detection helps protect the system in abnormal conditions.\u003c\/li\u003e\n\u003cli\u003eAnti-cold-air heating behavior reduces drafts during heat mode.\u003c\/li\u003e\n\u003cli\u003eBuilt-in pump with float switch (20.9\" lift) for quiet condensate removal.\u003c\/li\u003e\n\u003cli\u003eHyper outdoor unit supports heating operation down to -22°F ambient.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cdiv class=\"hvx-grid\"\u003e\n\u003cdiv class=\"hvx-kv\"\u003e\n\u003cp class=\"hvx-k\"\u003eIndoor Model\u003c\/p\u003e\n\u003cp class=\"hvx-v\"\u003e\u003ca href=\"https:\/\/hvacsupplies.com\/search?options%5Bprefix%5D=last\u0026amp;q=CH-RSH18MCT\" class=\"hvx-link\"\u003eCH-RSH18MCT\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"hvx-kv\"\u003e\n\u003cp class=\"hvx-k\"\u003eOutdoor Model\u003c\/p\u003e\n\u003cp class=\"hvx-v\"\u003e\u003ca href=\"https:\/\/hvacsupplies.com\/search?options%5Bprefix%5D=last\u0026amp;q=CH-RHP18-230VO\" class=\"hvx-link\"\u003eCH-RHP18-230VO\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"hvx-kv\"\u003e\n\u003cp class=\"hvx-k\"\u003eLine Set Size\u003c\/p\u003e\n\u003cp class=\"hvx-v\"\u003e1\/4\" Liquid • 1\/2\" Gas\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"hvx-kv\"\u003e\n\u003cp class=\"hvx-k\"\u003ePower\u003c\/p\u003e\n\u003cp class=\"hvx-v\"\u003e208–230V • 1Ph • 60Hz\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"hvx-kv\"\u003e\n\u003cp class=\"hvx-k\"\u003eMax Line Length\u003c\/p\u003e\n\u003cp class=\"hvx-v\"\u003e98.4 ft\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"hvx-kv\"\u003e\n\u003cp class=\"hvx-k\"\u003eLow-Ambient Heating\u003c\/p\u003e\n\u003cp class=\"hvx-v\"\u003eDown to -22°F\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"hvx-desc-card\"\u003e\n\u003ch3 class=\"hvx-section-title\"\u003eWhat’s Included\u003c\/h3\u003e\n\u003cul style=\"margin: 0; padding-left: 18px;\" class=\"hvx-muted\"\u003e\n\u003cli\u003eIndoor 4-way ceiling cassette: CH-RSH18MCT\u003c\/li\u003e\n\u003cli\u003eOutdoor condenser: CH-RHP18-230VO (Hyper)\u003c\/li\u003e\n\u003cli\u003eRemote control (indoor control package)\u003c\/li\u003e\n\u003cli\u003eCeiling Cassette Panel\u003c\/li\u003e\n\u003cli\u003eBuilt-in condensate pump with float switch (indoor)\u003c\/li\u003e\n\u003cli\u003eSmart Kit capability for app control (setup required)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"hvx-desc-card\"\u003e\n\u003ch3 class=\"hvx-section-title\"\u003eIndoor Specs (CH-RSH18MCT)\u003c\/h3\u003e\n\u003cdiv class=\"hvx-table-wrap\"\u003e\n\u003ctable class=\"hvx-table\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eSpec\u003c\/th\u003e\n\u003cth\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRefrigerant Type\u003c\/td\u003e\n\u003ctd\u003eR454B\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSystem Type\u003c\/td\u003e\n\u003ctd\u003eSingle Zone\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBTU Rated\u003c\/td\u003e\n\u003ctd\u003e18,000\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower\u003c\/td\u003e\n\u003ctd\u003e208–230V • 1Ph • 60Hz (Voltage Range: 187–253V)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSEER2 \/ EER2\u003c\/td\u003e\n\u003ctd\u003e20 \/ 12.5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDehumidification\u003c\/td\u003e\n\u003ctd\u003e4.23 pints\/day\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIndoor Airflow (CFM)\u003c\/td\u003e\n\u003ctd\u003e447.3 \/ 388.5 \/ 317.8 \/ 194.2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNoise (dB(A))\u003c\/td\u003e\n\u003ctd\u003e44.5 \/ 41 \/ 27.5 (H\/M\/L)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUnit Dimensions (W×D×H)\u003c\/td\u003e\n\u003ctd\u003e22.44 × 22.44 × 9.65 in\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNet \/ Gross Weight\u003c\/td\u003e\n\u003ctd\u003e35.27 \/ 41.89 lb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRefrigerant Piping\u003c\/td\u003e\n\u003ctd\u003e1\/4\" Liquid • 1\/2\" Gas\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDrain Pipe Diameter\u003c\/td\u003e\n\u003ctd\u003e1\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Range\u003c\/td\u003e\n\u003ctd\u003eCooling: 60–90°F • Heating: 32–86°F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMinimum Circuit Ampacity\u003c\/td\u003e\n\u003ctd\u003e3 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax Fuse\u003c\/td\u003e\n\u003ctd\u003e15 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"hvx-desc-card\"\u003e\n\u003ch3 class=\"hvx-section-title\"\u003eOutdoor Specs (CH-RHP18-230VO)\u003c\/h3\u003e\n\u003cdiv class=\"hvx-table-wrap\"\u003e\n\u003ctable class=\"hvx-table\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eSpec\u003c\/th\u003e\n\u003cth\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRefrigerant Type\u003c\/td\u003e\n\u003ctd\u003eR454B\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSystem Type\u003c\/td\u003e\n\u003ctd\u003eSingle-zone unit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBTU Rated\u003c\/td\u003e\n\u003ctd\u003e18,000\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCooling Capacity (Min–Max)\u003c\/td\u003e\n\u003ctd\u003e17,000 (6,500–18,800) BTU\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHeating Capacity (Min–Max)\u003c\/td\u003e\n\u003ctd\u003e19,000 (8,900–22,000) BTU\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSEER2 \/ EER2\u003c\/td\u003e\n\u003ctd\u003e18 \/ 12\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHSPF2 (Region IV \/ V)\u003c\/td\u003e\n\u003ctd\u003e10.5 \/ 9.0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCOP\u003c\/td\u003e\n\u003ctd\u003e3.37\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower\u003c\/td\u003e\n\u003ctd\u003e208–230V • 1Ph • 60Hz (Voltage Range: 187–253V)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax Pipe Length\u003c\/td\u003e\n\u003ctd\u003e98.4 ft\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax Height Difference\u003c\/td\u003e\n\u003ctd\u003e65.6 ft\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMinimum Circuit Ampacity\u003c\/td\u003e\n\u003ctd\u003e19 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax Fuse\u003c\/td\u003e\n\u003ctd\u003e20 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutdoor Airflow\u003c\/td\u003e\n\u003ctd\u003e1,765.8 CFM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutdoor Noise\u003c\/td\u003e\n\u003ctd\u003e59 dB(A)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUnit Dimensions (W×D×H)\u003c\/td\u003e\n\u003ctd\u003e35.04 × 13.46 × 26.50 in\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNet \/ Gross Weight\u003c\/td\u003e\n\u003ctd\u003e99.87 \/ 107.80 lb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAmbient Temperature\u003c\/td\u003e\n\u003ctd\u003eCooling: -22–122°F • Heating: -22–75°F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAdditional Charge\u003c\/td\u003e\n\u003ctd\u003e0.16 oz\/ft (1\/4\" liquid line)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"hvx-desc-card\"\u003e\n\u003ch3 class=\"hvx-section-title\"\u003eDocuments \u0026amp; Downloads\u003c\/h3\u003e\n\u003cul style=\"margin: 0; padding-left: 18px;\" class=\"hvx-muted\"\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/media.cooperandhunter.us\/4687\/CH-RHP18-230VO_CH-RSH18MCT.pdf\" class=\"hvx-link\"\u003eSubmittal Sheet: CH-RHP18-230VO + CH-RSH18MCT\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/media.cooperandhunter.us\/4118\/Installation-Manual-R454B-Outdoor-units--.pdf\" class=\"hvx-link\"\u003eOutdoor Units Installation Manual (R454B)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/media.cooperandhunter.us\/4200\/SlimDuct-Leaflet-R454B.pdf\" class=\"hvx-link\"\u003eSlimDuct Leaflet (R454B)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/media.cooperandhunter.us\/3309\/120N--uses-and-installation-manual.pdf\" class=\"hvx-link\"\u003e120N Wire Controller — Uses \u0026amp; Installation Manual\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/media.cooperandhunter.us\/4654\/Installation-manual-R454B-Ceiling-cassette_compressed.pdf\" class=\"hvx-link\"\u003eCeiling Cassette Installation Manual (R454B)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/media.cooperandhunter.us\/4655\/Owners_-manual-R454B-Ceiling-cassette_compressed.pdf\" class=\"hvx-link\"\u003eCeiling Cassette Owner’s Manual (R454B)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/media.cooperandhunter.us\/3198\/MultiZone-Combination-HYPER.pdf\" class=\"hvx-link\"\u003eMultiZone Combination Guide — Hyper\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/media.cooperandhunter.us\/3199\/MultiZone-Combination-Regular.pdf\" class=\"hvx-link\"\u003eMultiZone Combination Guide — Regular\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/media.cooperandhunter.us\/4158\/CH-RHP18-230VO-%2B-CH-PRO18MASTWM-230VI.pdf\" class=\"hvx-link\"\u003eSubmittal Sheet: CH-RHP18-230VO + CH-PRO18MASTWM-230VI\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/media.cooperandhunter.us\/4172\/CH-RHP18-230VO-%2B-CH-RH18MASTWM-230VI.pdf\" class=\"hvx-link\"\u003eSubmittal Sheet: CH-RHP18-230VO + CH-RH18MASTWM-230VI\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/media.cooperandhunter.us\/4204\/CH-RHP18-230VO-%2B-CH-RS18MDT-MS.pdf\" class=\"hvx-link\"\u003eSubmittal Sheet: CH-RHP18-230VO + CH-RS18MDT\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/media.cooperandhunter.us\/4251\/CH-RHP18-230VO-%2B-CH-RS18MAHU.pdf\" class=\"hvx-link\"\u003eSubmittal Sheet: CH-RHP18-230VO + CH-RS18MAHU\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/media.cooperandhunter.us\/4630\/CH-RHP18-230VO_CH-RSH18MFC.pdf\" class=\"hvx-link\"\u003eSubmittal Sheet: CH-RHP18-230VO + CH-RSH18MFC\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"hvx-desc-card\"\u003e\n\u003ch3 class=\"hvx-section-title\"\u003eImportant\u003c\/h3\u003e\n\u003cul style=\"margin: 0; padding-left: 18px;\" class=\"hvx-muted\"\u003e\n\u003cli\u003eProfessional installation is recommended.\u003c\/li\u003e\n\u003cli\u003eMatch line set sizes to the equipment: 1\/4\" liquid and 1\/2\" suction.\u003c\/li\u003e\n\u003cli\u003eVerify the dedicated circuit is sized per equipment MCA and local code.\u003c\/li\u003e\n\u003cli\u003eFor help choosing equipment, contact us: \u003ca href=\"https:\/\/hvacsupplies.com\/pages\/contact\" class=\"hvx-link\"\u003ehvacsupplies.com\/pages\/contact\u003c\/a\u003e • \u003ca href=\"tel:+18005438933\" class=\"hvx-link\"\u003e(800) 543-8933\u003c\/a\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"hvx-desc-card hvx-faq\"\u003e\n\u003ch3 class=\"hvx-section-title\"\u003eFAQs\u003c\/h3\u003e\n\u003cdetails\u003e\n\u003csummary\u003eWhat is the difference between RH and RSH cassettes?\u003c\/summary\u003e\n\u003cp class=\"hvx-muted\"\u003eRSH models add refrigerant leakage detection in addition to standard monitoring features.\u003c\/p\u003e\n\u003c\/details\u003e\n\u003cdetails\u003e\n\u003csummary\u003eWhat line set sizes are required for this 18K cassette?\u003c\/summary\u003e\n\u003cp class=\"hvx-muted\"\u003e1\/4\" liquid line and 1\/2\" suction (gas) line.\u003c\/p\u003e\n\u003c\/details\u003e\n\u003cdetails\u003e\n\u003csummary\u003eHow cold can the Hyper outdoor unit heat?\u003c\/summary\u003e\n\u003cp class=\"hvx-muted\"\u003eCH-RHP18-230VO supports heating operation down to -22°F ambient.\u003c\/p\u003e\n\u003c\/details\u003e\n\u003cdetails\u003e\n\u003csummary\u003eDoes the indoor cassette include a condensate pump?\u003c\/summary\u003e\n\u003cp class=\"hvx-muted\"\u003eYes. CH-RSH18MCT includes a built-in pump with float switch (20.9\" lift).\u003c\/p\u003e\n\u003c\/details\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e","brand":"Cooper\u0026Hunter","offers":[{"title":"No Installation","offer_id":42690946760747,"sku":"CH-RSH18MCT + CH-RHP18-230VO","price":2609.0,"currency_code":"USD","in_stock":true},{"title":"16FT","offer_id":42690946793515,"sku":"CH-RSH18MCT + CH-RHP18-230VO","price":2818.0,"currency_code":"USD","in_stock":true},{"title":"25FT","offer_id":42690946826283,"sku":"CH-RSH18MCT + CH-RHP18-230VO","price":2862.0,"currency_code":"USD","in_stock":true},{"title":"50FT","offer_id":42690946859051,"sku":"CH-RSH18MCT + CH-RHP18-230VO","price":3065.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0625\/5647\/1339\/files\/2-ZoneDuctlessMiniSplitAC_HeatPump48000BTU_26.png?v=1769199192"},{"product_id":"cooper-hunter-18-000-btu-pro-single-zone-four-way-ceiling-cassette-w-refrigerant-humidity-sensor-minisplit-heat-pump-system-r454b-230v","title":"Cooper\u0026Hunter 18,000 BTU Pro Single Zone Four-Way Ceiling Cassette w\/ Refrigerant \u0026 Humidity Sensor Minisplit Heat Pump System R454B 230V","description":"\u003cstyle\u003e\n    :root{--hvx-golden:#FAA819; --hvx-slate:#262626; --hvx-ivory:#F4F1E6; --hvx-border:#e2e0d5; --hvx-card-bg:#ffffff;}\n    .hvx-desc{background:var(--hvx-ivory); padding:18px; border-radius:18px; font-family:\"Articulat CF\",system-ui,-apple-system,Segoe UI,Roboto,Arial,sans-serif; color:#111;}\n    .hvx-desc-header{background:linear-gradient(120deg,var(--hvx-golden),var(--hvx-slate)); border-radius:16px; padding:16px 16px 14px; color:#fff; margin-bottom:14px;}\n    .hvx-eyebrow{font-size:12px; letter-spacing:.12em; text-transform:uppercase; opacity:.9; margin:0 0 6px;}\n    .hvx-title{font-family:\"Anton\",Impact,Haettenschweiler,\"Arial Narrow Bold\",sans-serif; font-size:26px; line-height:1.05; margin:0;}\n    .hvx-desc-card{background:var(--hvx-card-bg); border:1px solid var(--hvx-border); border-radius:16px; padding:14px; margin:12px 0; box-shadow:0 10px 18px rgba(0,0,0,.06);}\n    .hvx-section-title{margin:0 0 10px; font-size:13px; letter-spacing:.12em; text-transform:uppercase; display:inline-block; padding-bottom:6px; position:relative;}\n    .hvx-section-title:after{content:\"\"; position:absolute; left:0; bottom:0; height:3px; width:100%; border-radius:99px; background:linear-gradient(90deg,var(--hvx-golden),var(--hvx-slate));}\n    .hvx-badges{display:flex; flex-wrap:wrap; gap:8px; margin:6px 0 10px;}\n    .hvx-badge{display:inline-flex; align-items:center; gap:6px; padding:6px 10px; border-radius:999px; border:1px solid var(--hvx-border); background:#fff; font-size:12px; font-weight:600;}\n    .hvx-grid{display:grid; grid-template-columns:repeat(3,minmax(0,1fr)); gap:10px;}\n    .hvx-kv{border:1px solid var(--hvx-border); border-radius:14px; padding:10px; background:#fff;}\n    .hvx-k{font-size:12px; letter-spacing:.08em; text-transform:uppercase; color:#333; margin:0 0 6px;}\n    .hvx-v{font-size:14px; font-weight:700; margin:0;}\n    .hvx-table-wrap{overflow:auto; border-radius:14px; border:1px solid var(--hvx-border); background:#fff;}\n    table.hvx-table{width:100%; border-collapse:collapse; min-width:520px;}\n    .hvx-table th,.hvx-table td{padding:10px 12px; border-bottom:1px solid var(--hvx-border); vertical-align:top; font-size:14px;}\n    .hvx-table th{background:rgba(250,168,25,.12); text-align:left; font-size:12px; letter-spacing:.1em; text-transform:uppercase;}\n    .hvx-table tr:last-child td{border-bottom:none;}\n    .hvx-link{color:#111; text-decoration:none; border-bottom:2px solid rgba(250,168,25,.7);}\n    .hvx-link:hover{border-bottom-color:#111;}\n    .hvx-faq details{border:1px solid var(--hvx-border); border-radius:14px; background:#fff; padding:10px 12px; margin:10px 0;}\n    .hvx-faq summary{cursor:pointer; font-weight:800;}\n    .hvx-muted{color:#333; margin:6px 0 0;}\n    @media (max-width:720px){ .hvx-grid{grid-template-columns:1fr;} .hvx-title{font-size:24px;} }\n  \u003c\/style\u003e\n\u003cdiv class=\"hvx-desc\"\u003e\n\u003cdiv class=\"hvx-desc-header\"\u003e\n\u003cp class=\"hvx-eyebrow\"\u003eSingle Zone • 4-Way Ceiling Cassette • R454B • 208–230V\u003c\/p\u003e\n\u003ch2 class=\"hvx-title\"\u003eCooper\u0026amp;Hunter 18,000 BTU Pro Single Zone Four-Way Ceiling Cassette w\/ Refrigerant \u0026amp; Humidity Sensor Minisplit Heat Pump System R454B 230V\u003c\/h2\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"hvx-desc-card\"\u003e\n\u003ch3 class=\"hvx-section-title\"\u003eOverview\u003c\/h3\u003e\n\u003cp class=\"hvx-muted\"\u003eAn 18K four-way ceiling cassette pairing designed for even airflow distribution, clean-air support, and added diagnostic protection. The CH-RSH18MCT cassette includes refrigerant leakage detection in addition to humidity sensing and self-diagnosis features. Paired with the CH-RES18-230VO regular outdoor unit for efficient, dependable performance and strong SEER2.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"hvx-desc-card\"\u003e\n\u003ch3 class=\"hvx-section-title\"\u003eHighlights\u003c\/h3\u003e\n\u003cdiv class=\"hvx-badges\"\u003e\n\u003cspan class=\"hvx-badge\"\u003eR454B Refrigerant\u003c\/span\u003e \u003cspan class=\"hvx-badge\"\u003e360° Airflow Panel\u003c\/span\u003e \u003cspan class=\"hvx-badge\"\u003eLeak Detection (RSH)\u003c\/span\u003e \u003cspan class=\"hvx-badge\"\u003eHumidity Sensor\u003c\/span\u003e \u003cspan class=\"hvx-badge\"\u003eGoldFin Coil Coating\u003c\/span\u003e \u003cspan class=\"hvx-badge\"\u003eBuilt-In Condensate Pump\u003c\/span\u003e \u003cspan class=\"hvx-badge\"\u003eInverter Outdoor\u003c\/span\u003e\n\u003c\/div\u003e\n\u003cul style=\"margin: 0 0 10px; padding-left: 18px;\" class=\"hvx-muted\"\u003e\n\u003cli\u003eOmni-directional airflow and 360° panel helps distribute air evenly throughout the room.\u003c\/li\u003e\n\u003cli\u003eActivated carbon filtration support for fresher indoor air.\u003c\/li\u003e\n\u003cli\u003eRefrigerant leakage detection helps protect the system in abnormal conditions.\u003c\/li\u003e\n\u003cli\u003eBuilt-in pump with float switch (20.9\" lift) for quiet condensate removal.\u003c\/li\u003e\n\u003cli\u003eTurbo operation, sleep mode, and multiple fan speeds for comfort tuning.\u003c\/li\u003e\n\u003cli\u003eRegular outdoor unit supports heating operation down to -13°F ambient.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cdiv class=\"hvx-grid\"\u003e\n\u003cdiv class=\"hvx-kv\"\u003e\n\u003cp class=\"hvx-k\"\u003eIndoor Model\u003c\/p\u003e\n\u003cp class=\"hvx-v\"\u003e\u003ca href=\"https:\/\/hvacsupplies.com\/search?options%5Bprefix%5D=last\u0026amp;q=CH-RSH18MCT\" class=\"hvx-link\"\u003eCH-RSH18MCT\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"hvx-kv\"\u003e\n\u003cp class=\"hvx-k\"\u003eOutdoor Model\u003c\/p\u003e\n\u003cp class=\"hvx-v\"\u003e\u003ca href=\"https:\/\/hvacsupplies.com\/search?options%5Bprefix%5D=last\u0026amp;q=CH-RES18-230VO\" class=\"hvx-link\"\u003eCH-RES18-230VO\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"hvx-kv\"\u003e\n\u003cp class=\"hvx-k\"\u003eLine Set Size\u003c\/p\u003e\n\u003cp class=\"hvx-v\"\u003e1\/4\" Liquid • 1\/2\" Gas\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"hvx-kv\"\u003e\n\u003cp class=\"hvx-k\"\u003eOutdoor SEER2\u003c\/p\u003e\n\u003cp class=\"hvx-v\"\u003e20.7\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"hvx-kv\"\u003e\n\u003cp class=\"hvx-k\"\u003eMax Line Length\u003c\/p\u003e\n\u003cp class=\"hvx-v\"\u003e98.4 ft\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"hvx-kv\"\u003e\n\u003cp class=\"hvx-k\"\u003eLow-Ambient Heating\u003c\/p\u003e\n\u003cp class=\"hvx-v\"\u003eDown to -13°F\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"hvx-desc-card\"\u003e\n\u003ch3 class=\"hvx-section-title\"\u003eWhat’s Included\u003c\/h3\u003e\n\u003cul style=\"margin: 0; padding-left: 18px;\" class=\"hvx-muted\"\u003e\n\u003cli\u003eIndoor 4-way ceiling cassette: CH-RSH18MCT\u003c\/li\u003e\n\u003cli\u003eOutdoor condenser: CH-RES18-230VO (Regular)\u003c\/li\u003e\n\u003cli\u003eRemote control (indoor control package)\u003c\/li\u003e\n\u003cli\u003eCeiling Cassette Panel\u003c\/li\u003e\n\u003cli\u003eBuilt-in condensate pump with float switch (indoor)\u003c\/li\u003e\n\u003cli\u003eSmart Kit capability for app control (setup required)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"hvx-desc-card\"\u003e\n\u003ch3 class=\"hvx-section-title\"\u003eIndoor Specs (CH-RSH18MCT)\u003c\/h3\u003e\n\u003cdiv class=\"hvx-table-wrap\"\u003e\n\u003ctable class=\"hvx-table\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eSpec\u003c\/th\u003e\n\u003cth\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRefrigerant Type\u003c\/td\u003e\n\u003ctd\u003eR454B\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSystem Type\u003c\/td\u003e\n\u003ctd\u003eSingle Zone\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBTU Rated\u003c\/td\u003e\n\u003ctd\u003e18,000\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower\u003c\/td\u003e\n\u003ctd\u003e208–230V • 1Ph • 60Hz (Voltage Range: 187–253V)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSEER2 \/ EER2\u003c\/td\u003e\n\u003ctd\u003e20 \/ 12.5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDehumidification\u003c\/td\u003e\n\u003ctd\u003e4.23 pints\/day\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIndoor Airflow (CFM)\u003c\/td\u003e\n\u003ctd\u003e447.3 \/ 388.5 \/ 317.8 \/ 194.2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNoise (dB(A))\u003c\/td\u003e\n\u003ctd\u003e44.5 \/ 41 \/ 27.5 (H\/M\/L)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUnit Dimensions (W×D×H)\u003c\/td\u003e\n\u003ctd\u003e22.44 × 22.44 × 9.65 in\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNet \/ Gross Weight\u003c\/td\u003e\n\u003ctd\u003e35.27 \/ 41.89 lb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRefrigerant Piping\u003c\/td\u003e\n\u003ctd\u003e1\/4\" Liquid • 1\/2\" Gas\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDrain Pipe Diameter\u003c\/td\u003e\n\u003ctd\u003e1\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Range\u003c\/td\u003e\n\u003ctd\u003eCooling: 60–90°F • Heating: 32–86°F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMinimum Circuit Ampacity\u003c\/td\u003e\n\u003ctd\u003e3 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax Fuse\u003c\/td\u003e\n\u003ctd\u003e15 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"hvx-desc-card\"\u003e\n\u003ch3 class=\"hvx-section-title\"\u003eOutdoor Specs (CH-RES18-230VO)\u003c\/h3\u003e\n\u003cdiv class=\"hvx-table-wrap\"\u003e\n\u003ctable class=\"hvx-table\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eSpec\u003c\/th\u003e\n\u003cth\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRefrigerant Type\u003c\/td\u003e\n\u003ctd\u003eR454B\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSystem Type\u003c\/td\u003e\n\u003ctd\u003eSingle-zone unit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBTU Rated\u003c\/td\u003e\n\u003ctd\u003e18,000\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCooling Capacity (Min–Max)\u003c\/td\u003e\n\u003ctd\u003e17,000 (7,000–19,000) BTU\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHeating Capacity (Min–Max)\u003c\/td\u003e\n\u003ctd\u003e20,000 (5,500–22,000) BTU\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSEER2 \/ EER2\u003c\/td\u003e\n\u003ctd\u003e20 \/ 12.5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHSPF2 (Region IV \/ V)\u003c\/td\u003e\n\u003ctd\u003e10.5 \/ 8.2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCOP\u003c\/td\u003e\n\u003ctd\u003e3.47\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower\u003c\/td\u003e\n\u003ctd\u003e208–230V • 1Ph • 60Hz (Voltage Range: 187–253V)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax Pipe Length\u003c\/td\u003e\n\u003ctd\u003e98.4 ft\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax Height Difference\u003c\/td\u003e\n\u003ctd\u003e65.6 ft\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMinimum Circuit Ampacity\u003c\/td\u003e\n\u003ctd\u003e18 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax Fuse\u003c\/td\u003e\n\u003ctd\u003e20 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutdoor Airflow\u003c\/td\u003e\n\u003ctd\u003e1,765.8 CFM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutdoor Noise\u003c\/td\u003e\n\u003ctd\u003e59 dB(A)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUnit Dimensions (W×D×H)\u003c\/td\u003e\n\u003ctd\u003e35.04 × 13.46 × 26.5 in\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNet \/ Gross Weight\u003c\/td\u003e\n\u003ctd\u003e92.59 \/ 100.31 lb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAmbient Temperature\u003c\/td\u003e\n\u003ctd\u003eCooling: -13–122°F • Heating: -13–75°F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAdditional Charge\u003c\/td\u003e\n\u003ctd\u003e0.16 oz\/ft (1\/4\" liquid line)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"hvx-desc-card\"\u003e\n\u003ch3 class=\"hvx-section-title\"\u003eDocuments \u0026amp; Downloads\u003c\/h3\u003e\n\u003cul style=\"margin: 0; padding-left: 18px;\" class=\"hvx-muted\"\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/media.cooperandhunter.us\/4679\/CH-RES18-230VO_CH-RSH18MCT.pdf\" class=\"hvx-link\"\u003eSubmittal Sheet: CH-RES18-230VO + CH-RSH18MCT\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/media.cooperandhunter.us\/4157\/CH-RES18-230VO-%2B-CH-PRO18MASTWM-230VI.pdf\" class=\"hvx-link\"\u003eSubmittal Sheet: CH-RES18-230VO + CH-PRO18MASTWM-230VI\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/media.cooperandhunter.us\/4171\/CH-RES18-230VO-%2B-CH-RH18MASTWM-230VI.pdf\" class=\"hvx-link\"\u003eSubmittal Sheet: CH-RES18-230VO + CH-RH18MASTWM-230VI\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/media.cooperandhunter.us\/4211\/CH-RES18-230VO-%2B-CH-RS18MDT-MS.pdf\" class=\"hvx-link\"\u003eSubmittal Sheet: CH-RES18-230VO + CH-RS18MDT\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/media.cooperandhunter.us\/4625\/CH-RES18-230VO_CH-RSH18MFC.pdf\" class=\"hvx-link\"\u003eSubmittal Sheet: CH-RES18-230VO + CH-RSH18MFC\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/media.cooperandhunter.us\/4118\/Installation-Manual-R454B-Outdoor-units--.pdf\" class=\"hvx-link\"\u003eOutdoor Units Installation Manual (R454B)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/media.cooperandhunter.us\/4200\/SlimDuct-Leaflet-R454B.pdf\" class=\"hvx-link\"\u003eSlimDuct Leaflet (R454B)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/media.cooperandhunter.us\/3309\/120N--uses-and-installation-manual.pdf\" class=\"hvx-link\"\u003e120N Wire Controller — Uses \u0026amp; Installation Manual\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/media.cooperandhunter.us\/4654\/Installation-manual-R454B-Ceiling-cassette_compressed.pdf\" class=\"hvx-link\"\u003eCeiling Cassette Installation Manual (R454B)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/media.cooperandhunter.us\/4655\/Owners_-manual-R454B-Ceiling-cassette_compressed.pdf\" class=\"hvx-link\"\u003eCeiling Cassette Owner’s Manual (R454B)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/media.cooperandhunter.us\/3198\/MultiZone-Combination-HYPER.pdf\" class=\"hvx-link\"\u003eMultiZone Combination Guide — Hyper\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/media.cooperandhunter.us\/3199\/MultiZone-Combination-Regular.pdf\" class=\"hvx-link\"\u003eMultiZone Combination Guide — Regular\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/media.cooperandhunter.us\/4678\/CH-RES18-230VO_CH-RH18MCT.pdf\" class=\"hvx-link\"\u003eSubmittal Sheet: CH-RES18-230VO + CH-RH18MCT\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"hvx-desc-card\"\u003e\n\u003ch3 class=\"hvx-section-title\"\u003eImportant\u003c\/h3\u003e\n\u003cul style=\"margin: 0; padding-left: 18px;\" class=\"hvx-muted\"\u003e\n\u003cli\u003eProfessional installation is recommended.\u003c\/li\u003e\n\u003cli\u003eMatch line set sizes to the equipment: 1\/4\" liquid and 1\/2\" suction.\u003c\/li\u003e\n\u003cli\u003eVerify the dedicated circuit is sized per equipment MCA and local code.\u003c\/li\u003e\n\u003cli\u003eFor help choosing equipment, contact us: \u003ca href=\"https:\/\/hvacsupplies.com\/pages\/contact\" class=\"hvx-link\"\u003ehvacsupplies.com\/pages\/contact\u003c\/a\u003e • \u003ca href=\"tel:+18005438933\" class=\"hvx-link\"\u003e(800) 543-8933\u003c\/a\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"hvx-desc-card hvx-faq\"\u003e\n\u003ch3 class=\"hvx-section-title\"\u003eFAQs\u003c\/h3\u003e\n\u003cdetails\u003e\n\u003csummary\u003eWhat is the difference between RH and RSH cassettes?\u003c\/summary\u003e\n\u003cp class=\"hvx-muted\"\u003eRSH models add refrigerant leakage detection in addition to standard monitoring features.\u003c\/p\u003e\n\u003c\/details\u003e\n\u003cdetails\u003e\n\u003csummary\u003eWhat line set sizes are required for this 18K cassette?\u003c\/summary\u003e\n\u003cp class=\"hvx-muted\"\u003e1\/4\" liquid line and 1\/2\" suction (gas) line.\u003c\/p\u003e\n\u003c\/details\u003e\n\u003cdetails\u003e\n\u003csummary\u003eHow cold can the regular outdoor unit operate in heating?\u003c\/summary\u003e\n\u003cp class=\"hvx-muted\"\u003eCH-RES18-230VO supports heating operation down to -13°F ambient.\u003c\/p\u003e\n\u003c\/details\u003e\n\u003cdetails\u003e\n\u003csummary\u003eDoes the indoor cassette include a condensate pump?\u003c\/summary\u003e\n\u003cp class=\"hvx-muted\"\u003eYes. CH-RSH18MCT includes a built-in pump with float switch (20.9\" lift).\u003c\/p\u003e\n\u003c\/details\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e","brand":"Cooper\u0026Hunter","offers":[{"title":"No Installation","offer_id":42690946990123,"sku":"CH-RSH18MCT + CH-RES18-230VO","price":2229.0,"currency_code":"USD","in_stock":true},{"title":"16FT","offer_id":42690947022891,"sku":"CH-RSH18MCT + CH-RES18-230VO","price":2438.0,"currency_code":"USD","in_stock":true},{"title":"25FT","offer_id":42690947055659,"sku":"CH-RSH18MCT + CH-RES18-230VO","price":2483.0,"currency_code":"USD","in_stock":true},{"title":"50FT","offer_id":42690947088427,"sku":"CH-RSH18MCT + CH-RES18-230VO","price":2686.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0625\/5647\/1339\/files\/FourWay_Regular_Product_Hero_48_33b3a9f5-7a1c-442f-a881-e51e604eb6c3.png?v=1769199174"},{"product_id":"cooper-hunter-18-000-btu-hyper-single-zone-four-way-ceiling-cassette-w-humidity-sensor-minisplit-heat-pump-system-r454b-230v","title":"Cooper\u0026Hunter 18,000 BTU Hyper Single Zone Four-Way Ceiling Cassette w\/ Humidity Sensor Minisplit Heat Pump System R454B 230V","description":"\u003cstyle\u003e\n    :root{\n      --hvx-golden:#FAA819; --hvx-slate:#262626; --hvx-ivory:#F4F1E6; --hvx-border:#e2e0d5; --hvx-card-bg:#ffffff;\n    }\n    .hvx-desc{background:var(--hvx-ivory); padding:18px; border-radius:18px; font-family:\"Articulat CF\",system-ui,-apple-system,Segoe UI,Roboto,Arial,sans-serif; color:#111;}\n    .hvx-desc-header{background:linear-gradient(120deg,var(--hvx-golden),var(--hvx-slate)); border-radius:16px; padding:16px 16px 14px; color:#fff; margin-bottom:14px;}\n    .hvx-eyebrow{font-size:12px; letter-spacing:.12em; text-transform:uppercase; opacity:.9; margin:0 0 6px;}\n    .hvx-title{font-family:\"Anton\",Impact,Haettenschweiler,\"Arial Narrow Bold\",sans-serif; font-size:26px; line-height:1.05; margin:0;}\n    .hvx-desc-card{background:var(--hvx-card-bg); border:1px solid var(--hvx-border); border-radius:16px; padding:14px; margin:12px 0; box-shadow:0 10px 18px rgba(0,0,0,.06);}\n    .hvx-section-title{margin:0 0 10px; font-size:13px; letter-spacing:.12em; text-transform:uppercase; display:inline-block; padding-bottom:6px; position:relative;}\n    .hvx-section-title:after{content:\"\"; position:absolute; left:0; bottom:0; height:3px; width:100%; border-radius:99px; background:linear-gradient(90deg,var(--hvx-golden),var(--hvx-slate));}\n    .hvx-badges{display:flex; flex-wrap:wrap; gap:8px; margin:6px 0 10px;}\n    .hvx-badge{display:inline-flex; align-items:center; gap:6px; padding:6px 10px; border-radius:999px; border:1px solid var(--hvx-border); background:#fff; font-size:12px; font-weight:600;}\n    .hvx-grid{display:grid; grid-template-columns:repeat(3,minmax(0,1fr)); gap:10px;}\n    .hvx-kv{border:1px solid var(--hvx-border); border-radius:14px; padding:10px; background:#fff;}\n    .hvx-k{font-size:12px; letter-spacing:.08em; text-transform:uppercase; color:#333; margin:0 0 6px;}\n    .hvx-v{font-size:14px; font-weight:700; margin:0;}\n    .hvx-table-wrap{overflow:auto; border-radius:14px; border:1px solid var(--hvx-border); background:#fff;}\n    table.hvx-table{width:100%; border-collapse:collapse; min-width:520px;}\n    .hvx-table th,.hvx-table td{padding:10px 12px; border-bottom:1px solid var(--hvx-border); vertical-align:top; font-size:14px;}\n    .hvx-table th{background:rgba(250,168,25,.12); text-align:left; font-size:12px; letter-spacing:.1em; text-transform:uppercase;}\n    .hvx-table tr:last-child td{border-bottom:none;}\n    .hvx-link{color:#111; text-decoration:none; border-bottom:2px solid rgba(250,168,25,.7);}\n    .hvx-link:hover{border-bottom-color:#111;}\n    .hvx-faq details{border:1px solid var(--hvx-border); border-radius:14px; background:#fff; padding:10px 12px; margin:10px 0;}\n    .hvx-faq summary{cursor:pointer; font-weight:800;}\n    .hvx-muted{color:#333; margin:6px 0 0;}\n    @media (max-width:720px){ .hvx-grid{grid-template-columns:1fr;} .hvx-title{font-size:24px;} }\n  \u003c\/style\u003e\n\u003cdiv class=\"hvx-desc\"\u003e\n\u003cdiv class=\"hvx-desc-header\"\u003e\n\u003cp class=\"hvx-eyebrow\"\u003eSingle Zone • 4-Way Ceiling Cassette • R454B • 208–230V\u003c\/p\u003e\n\u003ch2 class=\"hvx-title\"\u003eCooper\u0026amp;Hunter 18,000 BTU Hyper Single Zone Four-Way Ceiling Cassette w\/ Humidity Sensor Minisplit Heat Pump System R454B 230V\u003c\/h2\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"hvx-desc-card\"\u003e\n\u003ch3 class=\"hvx-section-title\"\u003eOverview\u003c\/h3\u003e\n\u003cp class=\"hvx-muted\"\u003eAn 18K four-way ceiling cassette pairing built for even airflow, cleaner indoor air support, and strong cold-weather heating. The CH-RH18MCT indoor cassette delivers omni-directional comfort through a 360° air flow panel and includes a built-in condensate pump. Paired with the CH-RHP18-230VO Hyper outdoor unit for reliable heating performance down to -22°F.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"hvx-desc-card\"\u003e\n\u003ch3 class=\"hvx-section-title\"\u003eHighlights\u003c\/h3\u003e\n\u003cdiv class=\"hvx-badges\"\u003e\n\u003cspan class=\"hvx-badge\"\u003eR454B Refrigerant\u003c\/span\u003e \u003cspan class=\"hvx-badge\"\u003e360° Airflow Panel\u003c\/span\u003e \u003cspan class=\"hvx-badge\"\u003eHumidity Sensor\u003c\/span\u003e \u003cspan class=\"hvx-badge\"\u003eGoldFin Coil Coating\u003c\/span\u003e \u003cspan class=\"hvx-badge\"\u003eBuilt-In Condensate Pump\u003c\/span\u003e \u003cspan class=\"hvx-badge\"\u003eHyper Heating Outdoor\u003c\/span\u003e\n\u003c\/div\u003e\n\u003cul class=\"hvx-muted\" style=\"margin: 0 0 10px; padding-left: 18px;\"\u003e\n\u003cli\u003eOmni-directional airflow and 360° panel helps distribute air evenly throughout the room.\u003c\/li\u003e\n\u003cli\u003eActivated carbon filtration support for fresher indoor air.\u003c\/li\u003e\n\u003cli\u003eAnti-cold-air heating behavior reduces chilly drafts during heat mode.\u003c\/li\u003e\n\u003cli\u003eBuilt-in pump with float switch (20.9\" lift) for quiet condensate removal.\u003c\/li\u003e\n\u003cli\u003eTurbo operation, sleep mode, and multiple fan speeds for comfort tuning.\u003c\/li\u003e\n\u003cli\u003eHyper outdoor unit maintains heating operation in low ambient conditions down to -22°F.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cdiv class=\"hvx-grid\"\u003e\n\u003cdiv class=\"hvx-kv\"\u003e\n\u003cp class=\"hvx-k\"\u003eIndoor Model\u003c\/p\u003e\n\u003cp class=\"hvx-v\"\u003e\u003ca class=\"hvx-link\" href=\"https:\/\/hvacsupplies.com\/search?options%5Bprefix%5D=last\u0026amp;q=CH-RH18MCT\"\u003eCH-RH18MCT\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"hvx-kv\"\u003e\n\u003cp class=\"hvx-k\"\u003eOutdoor Model\u003c\/p\u003e\n\u003cp class=\"hvx-v\"\u003e\u003ca class=\"hvx-link\" href=\"https:\/\/hvacsupplies.com\/search?options%5Bprefix%5D=last\u0026amp;q=CH-RHP18-230VO\"\u003eCH-RHP18-230VO\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"hvx-kv\"\u003e\n\u003cp class=\"hvx-k\"\u003eLine Set Size\u003c\/p\u003e\n\u003cp class=\"hvx-v\"\u003e1\/4\" Liquid • 1\/2\" Gas\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"hvx-kv\"\u003e\n\u003cp class=\"hvx-k\"\u003ePower\u003c\/p\u003e\n\u003cp class=\"hvx-v\"\u003e208–230V • 1Ph • 60Hz\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"hvx-kv\"\u003e\n\u003cp class=\"hvx-k\"\u003eMax Line Length\u003c\/p\u003e\n\u003cp class=\"hvx-v\"\u003e98.4 ft\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"hvx-kv\"\u003e\n\u003cp class=\"hvx-k\"\u003eLow-Ambient Heating\u003c\/p\u003e\n\u003cp class=\"hvx-v\"\u003eDown to -22°F\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"hvx-desc-card\"\u003e\n\u003ch3 class=\"hvx-section-title\"\u003eWhat’s Included\u003c\/h3\u003e\n\u003cul class=\"hvx-muted\" style=\"margin: 0; padding-left: 18px;\"\u003e\n\u003cli\u003eIndoor 4-way ceiling cassette: CH-RH18MCT\u003c\/li\u003e\n\u003cli\u003eOutdoor condenser: CH-RHP18-230VO (Hyper)\u003c\/li\u003e\n\u003cli\u003eRemote control (indoor control package)\u003c\/li\u003e\n\u003cli\u003eCeiling Cassette Panel\u003c\/li\u003e\n\u003cli\u003eBuilt-in condensate pump with float switch (indoor)\u003c\/li\u003e\n\u003cli\u003eSmart Kit capability for app control (setup required)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"hvx-desc-card\"\u003e\n\u003ch3 class=\"hvx-section-title\"\u003eIndoor Specs (CH-RH18MCT)\u003c\/h3\u003e\n\u003cdiv class=\"hvx-table-wrap\"\u003e\n\u003ctable class=\"hvx-table\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eSpec\u003c\/th\u003e\n\u003cth\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRefrigerant Type\u003c\/td\u003e\n\u003ctd\u003eR454B\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSystem Type\u003c\/td\u003e\n\u003ctd\u003eSingle Zone\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBTU Rated\u003c\/td\u003e\n\u003ctd\u003e18,000\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower\u003c\/td\u003e\n\u003ctd\u003e208–230V • 1Ph • 60Hz (Voltage Range: 187–253V)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSEER2 \/ EER2\u003c\/td\u003e\n\u003ctd\u003e20 \/ 12.5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDehumidification\u003c\/td\u003e\n\u003ctd\u003e4.23 pints\/day\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIndoor Airflow (CFM)\u003c\/td\u003e\n\u003ctd\u003e447.3 \/ 388.5 \/ 317.8 \/ 194.2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNoise (dB(A))\u003c\/td\u003e\n\u003ctd\u003e44.5 \/ 41 \/ 27.5 (H\/M\/L)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUnit Dimensions (W×D×H)\u003c\/td\u003e\n\u003ctd\u003e22.44 × 22.44 × 9.65 in\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNet \/ Gross Weight\u003c\/td\u003e\n\u003ctd\u003e35.27 \/ 41.89 lb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRefrigerant Piping\u003c\/td\u003e\n\u003ctd\u003e1\/4\" Liquid • 1\/2\" Gas\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDrain Pipe Diameter\u003c\/td\u003e\n\u003ctd\u003e1\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Range\u003c\/td\u003e\n\u003ctd\u003eCooling: 60–90°F • Heating: 32–86°F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMinimum Circuit Ampacity\u003c\/td\u003e\n\u003ctd\u003e3 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax Fuse\u003c\/td\u003e\n\u003ctd\u003e15 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"hvx-desc-card\"\u003e\n\u003ch3 class=\"hvx-section-title\"\u003eOutdoor Specs (CH-RHP18-230VO)\u003c\/h3\u003e\n\u003cdiv class=\"hvx-table-wrap\"\u003e\n\u003ctable class=\"hvx-table\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eSpec\u003c\/th\u003e\n\u003cth\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRefrigerant Type\u003c\/td\u003e\n\u003ctd\u003eR454B\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSystem Type\u003c\/td\u003e\n\u003ctd\u003eSingle-zone unit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBTU Rated\u003c\/td\u003e\n\u003ctd\u003e18,000\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCooling Capacity (Min–Max)\u003c\/td\u003e\n\u003ctd\u003e17,000 (6,500–18,800) BTU\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHeating Capacity (Min–Max)\u003c\/td\u003e\n\u003ctd\u003e19,000 (8,900–22,000) BTU\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSEER2 \/ EER2\u003c\/td\u003e\n\u003ctd\u003e18 \/ 12\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHSPF2 (Region IV \/ V)\u003c\/td\u003e\n\u003ctd\u003e10.5 \/ 9.0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCOP\u003c\/td\u003e\n\u003ctd\u003e3.37\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower\u003c\/td\u003e\n\u003ctd\u003e208–230V • 1Ph • 60Hz (Voltage Range: 187–253V)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax Pipe Length\u003c\/td\u003e\n\u003ctd\u003e98.4 ft\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax Height Difference\u003c\/td\u003e\n\u003ctd\u003e65.6 ft\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMinimum Circuit Ampacity\u003c\/td\u003e\n\u003ctd\u003e19 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax Fuse\u003c\/td\u003e\n\u003ctd\u003e20 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutdoor Airflow\u003c\/td\u003e\n\u003ctd\u003e1,765.8 CFM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutdoor Noise\u003c\/td\u003e\n\u003ctd\u003e59 dB(A)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUnit Dimensions (W×D×H)\u003c\/td\u003e\n\u003ctd\u003e35.04 × 13.46 × 26.50 in\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNet \/ Gross Weight\u003c\/td\u003e\n\u003ctd\u003e99.87 \/ 107.80 lb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAmbient Temperature\u003c\/td\u003e\n\u003ctd\u003eCooling: -22–122°F • Heating: -22–75°F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAdditional Charge\u003c\/td\u003e\n\u003ctd\u003e0.16 oz\/ft (1\/4\" liquid line)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"hvx-desc-card\"\u003e\n\u003ch3 class=\"hvx-section-title\"\u003eDocuments \u0026amp; Downloads\u003c\/h3\u003e\n\u003cul class=\"hvx-muted\" style=\"margin: 0; padding-left: 18px;\"\u003e\n\u003cli\u003e\u003ca class=\"hvx-link\" href=\"https:\/\/media.cooperandhunter.us\/4686\/CH-RHP18-230VO_CH-RH18MCT.pdf\"\u003eSubmittal Sheet: CH-RHP18-230VO + CH-RH18MCT\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca class=\"hvx-link\" href=\"https:\/\/media.cooperandhunter.us\/4158\/CH-RHP18-230VO-%2B-CH-PRO18MASTWM-230VI.pdf\"\u003eSubmittal Sheet: CH-RHP18-230VO + CH-PRO18MASTWM-230VI\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca class=\"hvx-link\" href=\"https:\/\/media.cooperandhunter.us\/4172\/CH-RHP18-230VO-%2B-CH-RH18MASTWM-230VI.pdf\"\u003eSubmittal Sheet: CH-RHP18-230VO + CH-RH18MASTWM-230VI\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca class=\"hvx-link\" href=\"https:\/\/media.cooperandhunter.us\/4204\/CH-RHP18-230VO-%2B-CH-RS18MDT-MS.pdf\"\u003eSubmittal Sheet: CH-RHP18-230VO + CH-RS18MDT\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca class=\"hvx-link\" href=\"https:\/\/media.cooperandhunter.us\/4251\/CH-RHP18-230VO-%2B-CH-RS18MAHU.pdf\"\u003eSubmittal Sheet: CH-RHP18-230VO + CH-RS18MAHU\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca class=\"hvx-link\" href=\"https:\/\/media.cooperandhunter.us\/4118\/Installation-Manual-R454B-Outdoor-units--.pdf\"\u003eOutdoor Units Installation Manual (R454B)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca class=\"hvx-link\" href=\"https:\/\/media.cooperandhunter.us\/4200\/SlimDuct-Leaflet-R454B.pdf\"\u003eSlimDuct Leaflet (R454B)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca class=\"hvx-link\" href=\"https:\/\/media.cooperandhunter.us\/3309\/120N--uses-and-installation-manual.pdf\"\u003e120N Wire Controller — Uses \u0026amp; Installation Manual\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca class=\"hvx-link\" href=\"https:\/\/media.cooperandhunter.us\/4654\/Installation-manual-R454B-Ceiling-cassette_compressed.pdf\"\u003eCeiling Cassette Installation Manual (R454B)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca class=\"hvx-link\" href=\"https:\/\/media.cooperandhunter.us\/4655\/Owners_-manual-R454B-Ceiling-cassette_compressed.pdf\"\u003eCeiling Cassette Owner’s Manual (R454B)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca class=\"hvx-link\" href=\"https:\/\/media.cooperandhunter.us\/3198\/MultiZone-Combination-HYPER.pdf\"\u003eMultiZone Combination Guide — Hyper\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca class=\"hvx-link\" href=\"https:\/\/media.cooperandhunter.us\/3199\/MultiZone-Combination-Regular.pdf\"\u003eMultiZone Combination Guide — Regular\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"hvx-desc-card\"\u003e\n\u003ch3 class=\"hvx-section-title\"\u003eImportant\u003c\/h3\u003e\n\u003cul class=\"hvx-muted\" style=\"margin: 0; padding-left: 18px;\"\u003e\n\u003cli\u003eProfessional installation is recommended.\u003c\/li\u003e\n\u003cli\u003eMatch line set sizes to the equipment: 1\/4\" liquid and 1\/2\" suction.\u003c\/li\u003e\n\u003cli\u003eVerify the dedicated circuit is sized per equipment MCA and local code.\u003c\/li\u003e\n\u003cli\u003eFor help choosing equipment, contact us: \u003ca class=\"hvx-link\" href=\"https:\/\/hvacsupplies.com\/pages\/contact\"\u003ehvacsupplies.com\/pages\/contact\u003c\/a\u003e • \u003ca class=\"hvx-link\" href=\"tel:+18005438933\"\u003e(800) 543-8933\u003c\/a\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"hvx-desc-card hvx-faq\"\u003e\n\u003ch3 class=\"hvx-section-title\"\u003eFAQs\u003c\/h3\u003e\n\u003cdetails\u003e\n\u003csummary\u003eDoes the indoor cassette include a condensate pump?\u003c\/summary\u003e\n\u003cp class=\"hvx-muted\"\u003eYes. CH-RH18MCT includes a built-in pump with float switch (20.9\" lift).\u003c\/p\u003e\n\u003c\/details\u003e\n\u003cdetails\u003e\n\u003csummary\u003eWhat line set sizes are required for this 18K cassette?\u003c\/summary\u003e\n\u003cp class=\"hvx-muted\"\u003e1\/4\" liquid line and 1\/2\" suction (gas) line.\u003c\/p\u003e\n\u003c\/details\u003e\n\u003cdetails\u003e\n\u003csummary\u003eHow cold can the Hyper outdoor unit heat?\u003c\/summary\u003e\n\u003cp class=\"hvx-muted\"\u003eCH-RHP18-230VO supports heating operation down to -22°F ambient.\u003c\/p\u003e\n\u003c\/details\u003e\n\u003cdetails\u003e\n\u003csummary\u003eCan I control the system with an app?\u003c\/summary\u003e\n\u003cp class=\"hvx-muted\"\u003eSmart Kit capability supports app control through the C\u0026amp;H platform after setup.\u003c\/p\u003e\n\u003c\/details\u003e\n\u003cdetails\u003e\n\u003csummary\u003eIs a wall thermostat required?\u003c\/summary\u003e\n\u003cp class=\"hvx-muted\"\u003eNo. Remote control operation is supported; a wall thermostat can be added if desired.\u003c\/p\u003e\n\u003c\/details\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e","brand":"Cooper\u0026Hunter","offers":[{"title":"No Installation","offer_id":42690947645483,"sku":"CH-RH18MCT + CH-RHP18-230VO","price":2541.0,"currency_code":"USD","in_stock":true},{"title":"16FT","offer_id":42690947678251,"sku":"CH-RH18MCT + CH-RHP18-230VO","price":2750.0,"currency_code":"USD","in_stock":true},{"title":"25FT","offer_id":42690947711019,"sku":"CH-RH18MCT + CH-RHP18-230VO","price":2794.0,"currency_code":"USD","in_stock":true},{"title":"50FT","offer_id":42690947743787,"sku":"CH-RH18MCT + CH-RHP18-230VO","price":2997.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0625\/5647\/1339\/files\/2-ZoneDuctlessMiniSplitAC_HeatPump48000BTU_26.png?v=1769199192"},{"product_id":"cooper-hunter-18-000-btu-single-zone-four-way-ceiling-cassette-w-humidity-sensor-minisplit-heat-pump-system-r454b-230v","title":"Cooper\u0026Hunter 18,000 BTU Single Zone Four-Way Ceiling Cassette w\/ Humidity Sensor Minisplit Heat Pump System R454B 230V","description":"\u003cstyle\u003e\n    :root{--hvx-golden:#FAA819; --hvx-slate:#262626; --hvx-ivory:#F4F1E6; --hvx-border:#e2e0d5; --hvx-card-bg:#ffffff;}\n    .hvx-desc{background:var(--hvx-ivory); padding:18px; border-radius:18px; font-family:\"Articulat CF\",system-ui,-apple-system,Segoe UI,Roboto,Arial,sans-serif; color:#111;}\n    .hvx-desc-header{background:linear-gradient(120deg,var(--hvx-golden),var(--hvx-slate)); border-radius:16px; padding:16px 16px 14px; color:#fff; margin-bottom:14px;}\n    .hvx-eyebrow{font-size:12px; letter-spacing:.12em; text-transform:uppercase; opacity:.9; margin:0 0 6px;}\n    .hvx-title{font-family:\"Anton\",Impact,Haettenschweiler,\"Arial Narrow Bold\",sans-serif; font-size:26px; line-height:1.05; margin:0;}\n    .hvx-desc-card{background:var(--hvx-card-bg); border:1px solid var(--hvx-border); border-radius:16px; padding:14px; margin:12px 0; box-shadow:0 10px 18px rgba(0,0,0,.06);}\n    .hvx-section-title{margin:0 0 10px; font-size:13px; letter-spacing:.12em; text-transform:uppercase; display:inline-block; padding-bottom:6px; position:relative;}\n    .hvx-section-title:after{content:\"\"; position:absolute; left:0; bottom:0; height:3px; width:100%; border-radius:99px; background:linear-gradient(90deg,var(--hvx-golden),var(--hvx-slate));}\n    .hvx-badges{display:flex; flex-wrap:wrap; gap:8px; margin:6px 0 10px;}\n    .hvx-badge{display:inline-flex; align-items:center; gap:6px; padding:6px 10px; border-radius:999px; border:1px solid var(--hvx-border); background:#fff; font-size:12px; font-weight:600;}\n    .hvx-grid{display:grid; grid-template-columns:repeat(3,minmax(0,1fr)); gap:10px;}\n    .hvx-kv{border:1px solid var(--hvx-border); border-radius:14px; padding:10px; background:#fff;}\n    .hvx-k{font-size:12px; letter-spacing:.08em; text-transform:uppercase; color:#333; margin:0 0 6px;}\n    .hvx-v{font-size:14px; font-weight:700; margin:0;}\n    .hvx-table-wrap{overflow:auto; border-radius:14px; border:1px solid var(--hvx-border); background:#fff;}\n    table.hvx-table{width:100%; border-collapse:collapse; min-width:520px;}\n    .hvx-table th,.hvx-table td{padding:10px 12px; border-bottom:1px solid var(--hvx-border); vertical-align:top; font-size:14px;}\n    .hvx-table th{background:rgba(250,168,25,.12); text-align:left; font-size:12px; letter-spacing:.1em; text-transform:uppercase;}\n    .hvx-table tr:last-child td{border-bottom:none;}\n    .hvx-link{color:#111; text-decoration:none; border-bottom:2px solid rgba(250,168,25,.7);}\n    .hvx-link:hover{border-bottom-color:#111;}\n    .hvx-faq details{border:1px solid var(--hvx-border); border-radius:14px; background:#fff; padding:10px 12px; margin:10px 0;}\n    .hvx-faq summary{cursor:pointer; font-weight:800;}\n    .hvx-muted{color:#333; margin:6px 0 0;}\n    @media (max-width:720px){ .hvx-grid{grid-template-columns:1fr;} .hvx-title{font-size:24px;} }\n  \u003c\/style\u003e\n\u003cdiv class=\"hvx-desc\"\u003e\n\u003cdiv class=\"hvx-desc-header\"\u003e\n\u003cp class=\"hvx-eyebrow\"\u003eSingle Zone • 4-Way Ceiling Cassette • R454B • 208–230V\u003c\/p\u003e\n\u003ch2 class=\"hvx-title\"\u003eCooper\u0026amp;Hunter 18,000 BTU Single Zone Four-Way Ceiling Cassette w\/ Humidity Sensor Minisplit Heat Pump System R454B 230V\u003c\/h2\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"hvx-desc-card\"\u003e\n\u003ch3 class=\"hvx-section-title\"\u003eOverview\u003c\/h3\u003e\n\u003cp class=\"hvx-muted\"\u003eAn 18K four-way ceiling cassette pairing designed for even airflow, cleaner indoor air support, and efficient inverter operation. The CH-RH18MCT indoor cassette delivers omni-directional comfort through a 360° air flow panel and includes a built-in condensate pump. Paired with the CH-RES18-230VO regular outdoor unit for efficient, dependable heating and cooling.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"hvx-desc-card\"\u003e\n\u003ch3 class=\"hvx-section-title\"\u003eHighlights\u003c\/h3\u003e\n\u003cdiv class=\"hvx-badges\"\u003e\n\u003cspan class=\"hvx-badge\"\u003eR454B Refrigerant\u003c\/span\u003e \u003cspan class=\"hvx-badge\"\u003e360° Airflow Panel\u003c\/span\u003e \u003cspan class=\"hvx-badge\"\u003eHumidity Sensor\u003c\/span\u003e \u003cspan class=\"hvx-badge\"\u003eGoldFin Coil Coating\u003c\/span\u003e \u003cspan class=\"hvx-badge\"\u003eBuilt-In Condensate Pump\u003c\/span\u003e \u003cspan class=\"hvx-badge\"\u003eInverter Outdoor\u003c\/span\u003e\n\u003c\/div\u003e\n\u003cul style=\"margin: 0 0 10px; padding-left: 18px;\" class=\"hvx-muted\"\u003e\n\u003cli\u003eOmni-directional airflow and 360° panel helps distribute air evenly throughout the room.\u003c\/li\u003e\n\u003cli\u003eActivated carbon filtration support for fresher indoor air.\u003c\/li\u003e\n\u003cli\u003eAnti-cold-air heating behavior reduces drafts during heat mode.\u003c\/li\u003e\n\u003cli\u003eBuilt-in pump with float switch (20.9\" lift) for quiet condensate removal.\u003c\/li\u003e\n\u003cli\u003eTurbo operation, sleep mode, and multiple fan speeds for comfort tuning.\u003c\/li\u003e\n\u003cli\u003eRegular outdoor unit supports heating operation down to -13°F ambient.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cdiv class=\"hvx-grid\"\u003e\n\u003cdiv class=\"hvx-kv\"\u003e\n\u003cp class=\"hvx-k\"\u003eIndoor Model\u003c\/p\u003e\n\u003cp class=\"hvx-v\"\u003e\u003ca href=\"https:\/\/hvacsupplies.com\/search?options%5Bprefix%5D=last\u0026amp;q=CH-RH18MCT\" class=\"hvx-link\"\u003eCH-RH18MCT\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"hvx-kv\"\u003e\n\u003cp class=\"hvx-k\"\u003eOutdoor Model\u003c\/p\u003e\n\u003cp class=\"hvx-v\"\u003e\u003ca href=\"https:\/\/hvacsupplies.com\/search?options%5Bprefix%5D=last\u0026amp;q=CH-RES18-230VO\" class=\"hvx-link\"\u003eCH-RES18-230VO\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"hvx-kv\"\u003e\n\u003cp class=\"hvx-k\"\u003eLine Set Size\u003c\/p\u003e\n\u003cp class=\"hvx-v\"\u003e1\/4\" Liquid • 1\/2\" Gas\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"hvx-kv\"\u003e\n\u003cp class=\"hvx-k\"\u003eOutdoor SEER2\u003c\/p\u003e\n\u003cp class=\"hvx-v\"\u003e20.7\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"hvx-kv\"\u003e\n\u003cp class=\"hvx-k\"\u003eMax Line Length\u003c\/p\u003e\n\u003cp class=\"hvx-v\"\u003e98.4 ft\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"hvx-kv\"\u003e\n\u003cp class=\"hvx-k\"\u003eLow-Ambient Heating\u003c\/p\u003e\n\u003cp class=\"hvx-v\"\u003eDown to -13°F\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"hvx-desc-card\"\u003e\n\u003ch3 class=\"hvx-section-title\"\u003eWhat’s Included\u003c\/h3\u003e\n\u003cul style=\"margin: 0; padding-left: 18px;\" class=\"hvx-muted\"\u003e\n\u003cli\u003eIndoor 4-way ceiling cassette: CH-RH18MCT\u003c\/li\u003e\n\u003cli\u003eOutdoor condenser: CH-RES18-230VO (Regular)\u003c\/li\u003e\n\u003cli\u003eRemote control (indoor control package)\u003c\/li\u003e\n\u003cli\u003eCeiling Cassette Panel\u003c\/li\u003e\n\u003cli\u003eBuilt-in condensate pump with float switch (indoor)\u003c\/li\u003e\n\u003cli\u003eSmart Kit capability for app control (setup required)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"hvx-desc-card\"\u003e\n\u003ch3 class=\"hvx-section-title\"\u003eIndoor Specs (CH-RH18MCT)\u003c\/h3\u003e\n\u003cdiv class=\"hvx-table-wrap\"\u003e\n\u003ctable class=\"hvx-table\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eSpec\u003c\/th\u003e\n\u003cth\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRefrigerant Type\u003c\/td\u003e\n\u003ctd\u003eR454B\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSystem Type\u003c\/td\u003e\n\u003ctd\u003eSingle Zone\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBTU Rated\u003c\/td\u003e\n\u003ctd\u003e18,000\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower\u003c\/td\u003e\n\u003ctd\u003e208–230V • 1Ph • 60Hz (Voltage Range: 187–253V)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSEER2 \/ EER2\u003c\/td\u003e\n\u003ctd\u003e20 \/ 12.5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDehumidification\u003c\/td\u003e\n\u003ctd\u003e4.23 pints\/day\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIndoor Airflow (CFM)\u003c\/td\u003e\n\u003ctd\u003e447.3 \/ 388.5 \/ 317.8 \/ 194.2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNoise (dB(A))\u003c\/td\u003e\n\u003ctd\u003e44.5 \/ 41 \/ 27.5 (H\/M\/L)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUnit Dimensions (W×D×H)\u003c\/td\u003e\n\u003ctd\u003e22.44 × 22.44 × 9.65 in\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNet \/ Gross Weight\u003c\/td\u003e\n\u003ctd\u003e35.27 \/ 41.89 lb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRefrigerant Piping\u003c\/td\u003e\n\u003ctd\u003e1\/4\" Liquid • 1\/2\" Gas\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDrain Pipe Diameter\u003c\/td\u003e\n\u003ctd\u003e1\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Range\u003c\/td\u003e\n\u003ctd\u003eCooling: 60–90°F • Heating: 32–86°F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMinimum Circuit Ampacity\u003c\/td\u003e\n\u003ctd\u003e3 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax Fuse\u003c\/td\u003e\n\u003ctd\u003e15 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"hvx-desc-card\"\u003e\n\u003ch3 class=\"hvx-section-title\"\u003eOutdoor Specs (CH-RES18-230VO)\u003c\/h3\u003e\n\u003cdiv class=\"hvx-table-wrap\"\u003e\n\u003ctable class=\"hvx-table\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eSpec\u003c\/th\u003e\n\u003cth\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRefrigerant Type\u003c\/td\u003e\n\u003ctd\u003eR454B\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSystem Type\u003c\/td\u003e\n\u003ctd\u003eSingle-zone unit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBTU Rated\u003c\/td\u003e\n\u003ctd\u003e18,000\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCooling Capacity (Min–Max)\u003c\/td\u003e\n\u003ctd\u003e17,000 (7,000–19,000) BTU\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHeating Capacity (Min–Max)\u003c\/td\u003e\n\u003ctd\u003e20,000 (5,500–22,000) BTU\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSEER2 \/ EER2\u003c\/td\u003e\n\u003ctd\u003e20 \/ 12.5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHSPF2 (Region IV \/ V)\u003c\/td\u003e\n\u003ctd\u003e10.5 \/ 8.2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCOP\u003c\/td\u003e\n\u003ctd\u003e3.47\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower\u003c\/td\u003e\n\u003ctd\u003e208–230V • 1Ph • 60Hz (Voltage Range: 187–253V)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax Pipe Length\u003c\/td\u003e\n\u003ctd\u003e98.4 ft\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax Height Difference\u003c\/td\u003e\n\u003ctd\u003e65.6 ft\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMinimum Circuit Ampacity\u003c\/td\u003e\n\u003ctd\u003e18 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax Fuse\u003c\/td\u003e\n\u003ctd\u003e20 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutdoor Airflow\u003c\/td\u003e\n\u003ctd\u003e1,765.8 CFM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutdoor Noise\u003c\/td\u003e\n\u003ctd\u003e59 dB(A)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUnit Dimensions (W×D×H)\u003c\/td\u003e\n\u003ctd\u003e35.04 × 13.46 × 26.5 in\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNet \/ Gross Weight\u003c\/td\u003e\n\u003ctd\u003e92.59 \/ 100.31 lb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAmbient Temperature\u003c\/td\u003e\n\u003ctd\u003eCooling: -13–122°F • Heating: -13–75°F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAdditional Charge\u003c\/td\u003e\n\u003ctd\u003e0.16 oz\/ft (1\/4\" liquid line)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"hvx-desc-card\"\u003e\n\u003ch3 class=\"hvx-section-title\"\u003eDocuments \u0026amp; Downloads\u003c\/h3\u003e\n\u003cul style=\"margin: 0; padding-left: 18px;\" class=\"hvx-muted\"\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/media.cooperandhunter.us\/4678\/CH-RES18-230VO_CH-RH18MCT.pdf\" class=\"hvx-link\"\u003eSubmittal Sheet: CH-RES18-230VO + CH-RH18MCT\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/media.cooperandhunter.us\/4157\/CH-RES18-230VO-%2B-CH-PRO18MASTWM-230VI.pdf\" class=\"hvx-link\"\u003eSubmittal Sheet: CH-RES18-230VO + CH-PRO18MASTWM-230VI\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/media.cooperandhunter.us\/4171\/CH-RES18-230VO-%2B-CH-RH18MASTWM-230VI.pdf\" class=\"hvx-link\"\u003eSubmittal Sheet: CH-RES18-230VO + CH-RH18MASTWM-230VI\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/media.cooperandhunter.us\/4211\/CH-RES18-230VO-%2B-CH-RS18MDT-MS.pdf\" class=\"hvx-link\"\u003eSubmittal Sheet: CH-RES18-230VO + CH-RS18MDT\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/media.cooperandhunter.us\/4118\/Installation-Manual-R454B-Outdoor-units--.pdf\" class=\"hvx-link\"\u003eOutdoor Units Installation Manual (R454B)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/media.cooperandhunter.us\/4200\/SlimDuct-Leaflet-R454B.pdf\" class=\"hvx-link\"\u003eSlimDuct Leaflet (R454B)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/media.cooperandhunter.us\/3309\/120N--uses-and-installation-manual.pdf\" class=\"hvx-link\"\u003e120N Wire Controller — Uses \u0026amp; Installation Manual\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/media.cooperandhunter.us\/4654\/Installation-manual-R454B-Ceiling-cassette_compressed.pdf\" class=\"hvx-link\"\u003eCeiling Cassette Installation Manual (R454B)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/media.cooperandhunter.us\/4655\/Owners_-manual-R454B-Ceiling-cassette_compressed.pdf\" class=\"hvx-link\"\u003eCeiling Cassette Owner’s Manual (R454B)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/media.cooperandhunter.us\/3198\/MultiZone-Combination-HYPER.pdf\" class=\"hvx-link\"\u003eMultiZone Combination Guide — Hyper\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/media.cooperandhunter.us\/3199\/MultiZone-Combination-Regular.pdf\" class=\"hvx-link\"\u003eMultiZone Combination Guide — Regular\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"hvx-desc-card\"\u003e\n\u003ch3 class=\"hvx-section-title\"\u003eImportant\u003c\/h3\u003e\n\u003cul style=\"margin: 0; padding-left: 18px;\" class=\"hvx-muted\"\u003e\n\u003cli\u003eProfessional installation is recommended.\u003c\/li\u003e\n\u003cli\u003eMatch line set sizes to the equipment: 1\/4\" liquid and 1\/2\" suction.\u003c\/li\u003e\n\u003cli\u003eVerify the dedicated circuit is sized per equipment MCA and local code.\u003c\/li\u003e\n\u003cli\u003eFor help choosing equipment, contact us: \u003ca href=\"https:\/\/hvacsupplies.com\/pages\/contact\" class=\"hvx-link\"\u003ehvacsupplies.com\/pages\/contact\u003c\/a\u003e • \u003ca href=\"tel:+18005438933\" class=\"hvx-link\"\u003e(800) 543-8933\u003c\/a\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"hvx-desc-card hvx-faq\"\u003e\n\u003ch3 class=\"hvx-section-title\"\u003eFAQs\u003c\/h3\u003e\n\u003cdetails\u003e\n\u003csummary\u003eDoes the indoor cassette include a condensate pump?\u003c\/summary\u003e\n\u003cp class=\"hvx-muted\"\u003eYes. CH-RH18MCT includes a built-in pump with float switch (20.9\" lift).\u003c\/p\u003e\n\u003c\/details\u003e\n\u003cdetails\u003e\n\u003csummary\u003eWhat line set sizes are required for this 18K cassette?\u003c\/summary\u003e\n\u003cp class=\"hvx-muted\"\u003e1\/4\" liquid line and 1\/2\" suction (gas) line.\u003c\/p\u003e\n\u003c\/details\u003e\n\u003cdetails\u003e\n\u003csummary\u003eHow cold can the regular outdoor unit operate in heating?\u003c\/summary\u003e\n\u003cp class=\"hvx-muted\"\u003eCH-RES18-230VO supports heating operation down to -13°F ambient.\u003c\/p\u003e\n\u003c\/details\u003e\n\u003cdetails\u003e\n\u003csummary\u003eCan I control the system with an app?\u003c\/summary\u003e\n\u003cp class=\"hvx-muted\"\u003eSmart Kit capability supports app control through the C\u0026amp;H platform after setup.\u003c\/p\u003e\n\u003c\/details\u003e\n\u003cdetails\u003e\n\u003csummary\u003eIs a wall thermostat required?\u003c\/summary\u003e\n\u003cp class=\"hvx-muted\"\u003eNo. Remote control operation is supported; a wall thermostat can be added if desired.\u003c\/p\u003e\n\u003c\/details\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e","brand":"Cooper\u0026Hunter","offers":[{"title":"No Installation","offer_id":42690947907627,"sku":"CH-RH18MCT + CH-RES18-230VO","price":2166.0,"currency_code":"USD","in_stock":true},{"title":"16FT","offer_id":42690947940395,"sku":"CH-RH18MCT + CH-RES18-230VO","price":2375.0,"currency_code":"USD","in_stock":true},{"title":"25FT","offer_id":42690947973163,"sku":"CH-RH18MCT + CH-RES18-230VO","price":2419.0,"currency_code":"USD","in_stock":true},{"title":"50FT","offer_id":42690948005931,"sku":"CH-RH18MCT + CH-RES18-230VO","price":2622.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0625\/5647\/1339\/files\/FourWay_Regular_Product_Hero_48_33b3a9f5-7a1c-442f-a881-e51e604eb6c3.png?v=1769199174"},{"product_id":"cooper-hunter-24-000-btu-hyper-pro-single-zone-four-way-ceiling-cassette-w-refrigerant-humidity-sensor-minisplit-heat-pump-system-r454b-230v","title":"Cooper\u0026Hunter 24,000 BTU Hyper Pro Single Zone Four-Way Ceiling Cassette w\/ Refrigerant \u0026 Humidity Sensor Minisplit Heat Pump System R454B 230V","description":"\u003cstyle\u003e\n    :root{--hvx-golden:#FAA819;--hvx-slate:#262626;--hvx-ivory:#F4F1E6;--hvx-border:#e2e0d5;--hvx-card-bg:#ffffff;}\n    .hvx-desc{background:var(--hvx-ivory);padding:18px;border-radius:18px;font-family:\"Articulat CF\",system-ui,-apple-system,Segoe UI,Roboto,Arial,sans-serif;color:#111;}\n    .hvx-desc-header{background:linear-gradient(120deg,var(--hvx-golden),var(--hvx-slate));border-radius:16px;padding:16px 16px 14px;color:#fff;margin-bottom:14px;}\n    .hvx-eyebrow{font-size:12px;letter-spacing:.12em;text-transform:uppercase;opacity:.9;margin:0 0 6px;}\n    .hvx-title{font-family:\"Anton\",Impact,Haettenschweiler,\"Arial Narrow Bold\",sans-serif;font-size:26px;line-height:1.05;margin:0;}\n    .hvx-desc-card{background:var(--hvx-card-bg);border:1px solid var(--hvx-border);border-radius:16px;padding:14px;margin:12px 0;box-shadow:0 10px 18px rgba(0,0,0,.06);}\n    .hvx-section-title{margin:0 0 10px;font-size:13px;letter-spacing:.12em;text-transform:uppercase;display:inline-block;padding-bottom:6px;position:relative;}\n    .hvx-section-title:after{content:\"\";position:absolute;left:0;bottom:0;height:3px;width:100%;border-radius:99px;background:linear-gradient(90deg,var(--hvx-golden),var(--hvx-slate));}\n    .hvx-badges{display:flex;flex-wrap:wrap;gap:8px;margin:6px 0 10px;}\n    .hvx-badge{display:inline-flex;align-items:center;gap:6px;padding:6px 10px;border-radius:999px;border:1px solid var(--hvx-border);background:#fff;font-size:12px;font-weight:600;}\n    .hvx-grid{display:grid;grid-template-columns:repeat(3,minmax(0,1fr));gap:10px;}\n    .hvx-kv{border:1px solid var(--hvx-border);border-radius:14px;padding:10px;background:#fff;}\n    .hvx-k{font-size:12px;letter-spacing:.08em;text-transform:uppercase;color:#333;margin:0 0 6px;}\n    .hvx-v{font-size:14px;font-weight:700;margin:0;}\n    .hvx-table-wrap{overflow:auto;border-radius:14px;border:1px solid var(--hvx-border);background:#fff;}\n    table.hvx-table{width:100%;border-collapse:collapse;min-width:520px;}\n    .hvx-table th,.hvx-table td{padding:10px 12px;border-bottom:1px solid var(--hvx-border);vertical-align:top;font-size:14px;}\n    .hvx-table th{background:rgba(250,168,25,.12);text-align:left;font-size:12px;letter-spacing:.1em;text-transform:uppercase;}\n    .hvx-table tr:last-child td{border-bottom:none;}\n    .hvx-link{color:#111;text-decoration:none;border-bottom:2px solid rgba(250,168,25,.7);}\n    .hvx-link:hover{border-bottom-color:#111;}\n    .hvx-faq details{border:1px solid var(--hvx-border);border-radius:14px;background:#fff;padding:10px 12px;margin:10px 0;}\n    .hvx-faq summary{cursor:pointer;font-weight:800;}\n    .hvx-muted{color:#333;margin:6px 0 0;}\n    @media (max-width:720px){.hvx-grid{grid-template-columns:1fr;}.hvx-title{font-size:24px;}}\n  \u003c\/style\u003e\n\u003cdiv class=\"hvx-desc\"\u003e\n\u003cdiv class=\"hvx-desc-header\"\u003e\n\u003cp class=\"hvx-eyebrow\"\u003eSingle Zone • 4-Way Ceiling Cassette • R454B • 208–230V\u003c\/p\u003e\n\u003ch2 class=\"hvx-title\"\u003eCooper\u0026amp;Hunter 24,000 BTU Hyper Pro Single Zone Four-Way Ceiling Cassette w\/ Refrigerant \u0026amp; Humidity Sensor Minisplit Heat Pump System R454B 230V\u003c\/h2\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"hvx-desc-card\"\u003e\n\u003ch3 class=\"hvx-section-title\"\u003eOverview\u003c\/h3\u003e\n\u003cp class=\"hvx-muted\"\u003eA 24K four-way ceiling cassette pairing designed for wide, even airflow with added system protection. The CH-RSH24MCT cassette includes refrigerant leakage detection plus humidity sensing and self-diagnosis features, and includes a built-in condensate pump. Pair it with the CH-RHP24-230VO Hyper outdoor unit for low-ambient heating down to -22°F.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"hvx-desc-card\"\u003e\n\u003ch3 class=\"hvx-section-title\"\u003eHighlights\u003c\/h3\u003e\n\u003cdiv class=\"hvx-badges\"\u003e\n\u003cspan class=\"hvx-badge\"\u003eR454B Refrigerant\u003c\/span\u003e \u003cspan class=\"hvx-badge\"\u003e360° Airflow Panel\u003c\/span\u003e \u003cspan class=\"hvx-badge\"\u003eLeak Detection (RSH)\u003c\/span\u003e \u003cspan class=\"hvx-badge\"\u003eHumidity Sensor\u003c\/span\u003e \u003cspan class=\"hvx-badge\"\u003eGoldFin Coil Coating\u003c\/span\u003e \u003cspan class=\"hvx-badge\"\u003eBuilt-In Condensate Pump\u003c\/span\u003e \u003cspan class=\"hvx-badge\"\u003eHyper Heating Outdoor\u003c\/span\u003e\n\u003c\/div\u003e\n\u003cul style=\"margin: 0 0 10px; padding-left: 18px;\" class=\"hvx-muted\"\u003e\n\u003cli\u003eOmni-directional airflow and 360° panel helps distribute air evenly throughout the room.\u003c\/li\u003e\n\u003cli\u003eActivated carbon filtration support for fresher indoor air.\u003c\/li\u003e\n\u003cli\u003eRefrigerant leakage detection helps protect the system in abnormal conditions.\u003c\/li\u003e\n\u003cli\u003eAnti-cold-air heating behavior reduces drafts during heat mode.\u003c\/li\u003e\n\u003cli\u003eBuilt-in pump with float switch (20.9\" lift) for quiet condensate removal.\u003c\/li\u003e\n\u003cli\u003eHyper outdoor unit supports heating operation down to -22°F ambient.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cdiv class=\"hvx-grid\"\u003e\n\u003cdiv class=\"hvx-kv\"\u003e\n\u003cp class=\"hvx-k\"\u003eIndoor Model\u003c\/p\u003e\n\u003cp class=\"hvx-v\"\u003e\u003ca href=\"https:\/\/hvacsupplies.com\/search?options%5Bprefix%5D=last\u0026amp;q=CH-RSH24MCT\" class=\"hvx-link\"\u003eCH-RSH24MCT\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"hvx-kv\"\u003e\n\u003cp class=\"hvx-k\"\u003eOutdoor Model\u003c\/p\u003e\n\u003cp class=\"hvx-v\"\u003e\u003ca href=\"https:\/\/hvacsupplies.com\/search?options%5Bprefix%5D=last\u0026amp;q=CH-RHP24-230VO\" class=\"hvx-link\"\u003eCH-RHP24-230VO\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"hvx-kv\"\u003e\n\u003cp class=\"hvx-k\"\u003eLine Set Size\u003c\/p\u003e\n\u003cp class=\"hvx-v\"\u003e3\/8\" Liquid • 5\/8\" Gas\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"hvx-kv\"\u003e\n\u003cp class=\"hvx-k\"\u003ePower\u003c\/p\u003e\n\u003cp class=\"hvx-v\"\u003e208–230V • 1Ph • 60Hz\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"hvx-kv\"\u003e\n\u003cp class=\"hvx-k\"\u003eMax Line Length\u003c\/p\u003e\n\u003cp class=\"hvx-v\"\u003e164 ft\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"hvx-kv\"\u003e\n\u003cp class=\"hvx-k\"\u003eLow-Ambient Heating\u003c\/p\u003e\n\u003cp class=\"hvx-v\"\u003eDown to -22°F\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"hvx-desc-card\"\u003e\n\u003ch3 class=\"hvx-section-title\"\u003eWhat’s Included\u003c\/h3\u003e\n\u003cul style=\"margin: 0; padding-left: 18px;\" class=\"hvx-muted\"\u003e\n\u003cli\u003eIndoor 4-way ceiling cassette: CH-RSH24MCT\u003c\/li\u003e\n\u003cli\u003eOutdoor condenser: CH-RHP24-230VO (Hyper)\u003c\/li\u003e\n\u003cli\u003eRemote control (indoor control package)\u003c\/li\u003e\n\u003cli\u003eCeiling Cassette Panel\u003c\/li\u003e\n\u003cli\u003eBuilt-in condensate pump with float switch (indoor)\u003c\/li\u003e\n\u003cli\u003eSmart Kit capability for app control (setup required)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"hvx-desc-card\"\u003e\n\u003ch3 class=\"hvx-section-title\"\u003eIndoor Specs (CH-RSH24MCT)\u003c\/h3\u003e\n\u003cdiv class=\"hvx-table-wrap\"\u003e\n\u003ctable class=\"hvx-table\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eSpec\u003c\/th\u003e\n\u003cth\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRefrigerant Type\u003c\/td\u003e\n\u003ctd\u003eR454B\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSystem Type\u003c\/td\u003e\n\u003ctd\u003eSingle Zone\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBTU Rated\u003c\/td\u003e\n\u003ctd\u003e24,000\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower\u003c\/td\u003e\n\u003ctd\u003e208–230V • 1Ph • 60Hz (Voltage Range: 187–253V)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSEER2 \/ EER2\u003c\/td\u003e\n\u003ctd\u003e20.7 \/ 12\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDehumidification\u003c\/td\u003e\n\u003ctd\u003e4.99 pints\/day\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIndoor Airflow (CFM)\u003c\/td\u003e\n\u003ctd\u003e765.2 \/ 706.3 \/ 635.7 \/ 547.4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNoise (dB(A))\u003c\/td\u003e\n\u003ctd\u003e45 \/ 42.5 \/ 33.5 (H\/M\/L)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUnit Dimensions (W×D×H)\u003c\/td\u003e\n\u003ctd\u003e32.68 × 32.68 × 8.07 in\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNet \/ Gross Weight\u003c\/td\u003e\n\u003ctd\u003e47.18 \/ 59.08 lb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRefrigerant Piping\u003c\/td\u003e\n\u003ctd\u003e3\/8\" Liquid • 5\/8\" Gas\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDrain Pipe Diameter\u003c\/td\u003e\n\u003ctd\u003e1\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Range\u003c\/td\u003e\n\u003ctd\u003eCooling: 60–90°F • Heating: 32–86°F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMinimum Circuit Ampacity\u003c\/td\u003e\n\u003ctd\u003e3 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax Fuse\u003c\/td\u003e\n\u003ctd\u003e15 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"hvx-desc-card\"\u003e\n\u003ch3 class=\"hvx-section-title\"\u003eOutdoor Specs (CH-RHP24-230VO)\u003c\/h3\u003e\n\u003cdiv class=\"hvx-table-wrap\"\u003e\n\u003ctable class=\"hvx-table\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eSpec\u003c\/th\u003e\n\u003cth\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRefrigerant Type\u003c\/td\u003e\n\u003ctd\u003eR454B\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBTU Rated\u003c\/td\u003e\n\u003ctd\u003e24,000\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCooling Capacity (Min–Max)\u003c\/td\u003e\n\u003ctd\u003e24,000 (12,600–27,900) BTU\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHeating Capacity (Min–Max)\u003c\/td\u003e\n\u003ctd\u003e29,000 (11,800–29,700) BTU\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHSPF2 (Region IV \/ V)\u003c\/td\u003e\n\u003ctd\u003e13.5 \/ 9.8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCOP\u003c\/td\u003e\n\u003ctd\u003e3.42\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower\u003c\/td\u003e\n\u003ctd\u003e208–230V • 1Ph • 60Hz (Voltage Range: 187–253V)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax Pipe Length\u003c\/td\u003e\n\u003ctd\u003e164 ft\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax Height Difference\u003c\/td\u003e\n\u003ctd\u003e82 ft\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMinimum Circuit Ampacity\u003c\/td\u003e\n\u003ctd\u003e24.9 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax Fuse\u003c\/td\u003e\n\u003ctd\u003e25 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutdoor Airflow\u003c\/td\u003e\n\u003ctd\u003e2,235.3 CFM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutdoor Noise\u003c\/td\u003e\n\u003ctd\u003e61.5 dB(A)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUnit Dimensions (W×D×H)\u003c\/td\u003e\n\u003ctd\u003e37.24 × 16.14 × 31.89 in\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNet \/ Gross Weight\u003c\/td\u003e\n\u003ctd\u003e130.29 \/ 141.31 lb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAmbient Temperature\u003c\/td\u003e\n\u003ctd\u003eCooling: -22–122°F • Heating: -22–75°F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAdditional Charge\u003c\/td\u003e\n\u003ctd\u003e0.32 oz\/ft (3\/8\" liquid line)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"hvx-desc-card\"\u003e\n\u003ch3 class=\"hvx-section-title\"\u003eDocuments \u0026amp; Downloads\u003c\/h3\u003e\n\u003cul style=\"margin: 0; padding-left: 18px;\" class=\"hvx-muted\"\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/media.cooperandhunter.us\/4688\/CH-RHP24-230VO_CH-RH24MCT.pdf\" class=\"hvx-link\"\u003eSubmittal Sheet: CH-RHP24-230VO + CH-RH24MCT\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/media.cooperandhunter.us\/4681\/CH-RES24-230VO_CH-RSH24MCT.pdf\" class=\"hvx-link\"\u003eSubmittal Sheet: CH-RES24-230VO + CH-RSH24MCT\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/media.cooperandhunter.us\/4118\/Installation-Manual-R454B-Outdoor-units--.pdf\" class=\"hvx-link\"\u003eOutdoor Units Installation Manual (R454B)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/media.cooperandhunter.us\/4200\/SlimDuct-Leaflet-R454B.pdf\" class=\"hvx-link\"\u003eSlimDuct Leaflet (R454B)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/media.cooperandhunter.us\/4654\/Installation-manual-R454B-Ceiling-cassette_compressed.pdf\" class=\"hvx-link\"\u003eCeiling Cassette Installation Manual (R454B)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/media.cooperandhunter.us\/4655\/Owners_-manual-R454B-Ceiling-cassette_compressed.pdf\" class=\"hvx-link\"\u003eCeiling Cassette Owner’s Manual (R454B)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/media.cooperandhunter.us\/3309\/120N--uses-and-installation-manual.pdf\" class=\"hvx-link\"\u003e120N Wire Controller — Uses \u0026amp; Installation Manual\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/media.cooperandhunter.us\/3198\/MultiZone-Combination-HYPER.pdf\" class=\"hvx-link\"\u003eMultiZone Combination Guide — Hyper\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/media.cooperandhunter.us\/3199\/MultiZone-Combination-Regular.pdf\" class=\"hvx-link\"\u003eMultiZone Combination Guide — Regular\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/media.cooperandhunter.us\/3959\/CH-RHP24-230VO-%2B-CH-RS24MAHU.pdf\" class=\"hvx-link\"\u003eSubmittal Sheet: CH-RHP24-230VO + CH-RS24MAHU\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/media.cooperandhunter.us\/4160\/CH-RHP24-230VO-%2B-CH-PRO24MASTWM-230VI.pdf\" class=\"hvx-link\"\u003eSubmittal Sheet: CH-RHP24-230VO + CH-PRO24MASTWM-230VI\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/media.cooperandhunter.us\/4174\/CH-RHP24-230VO-%2B-CH-RH24MASTWM-230VI.pdf\" class=\"hvx-link\"\u003eSubmittal Sheet: CH-RHP24-230VO + CH-RH24MASTWM-230VI\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/media.cooperandhunter.us\/4205\/CH-RHP24-230VO-%2B-CH-RS24MDT-HS.pdf\" class=\"hvx-link\"\u003eSubmittal Sheet: CH-RHP24-230VO + CH-RS24MDT-HS\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/media.cooperandhunter.us\/4631\/CH-RHP24-230VO_CH-RSH24MFC.pdf\" class=\"hvx-link\"\u003eSubmittal Sheet: CH-RHP24-230VO + CH-RSH24MFC\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"hvx-desc-card\"\u003e\n\u003ch3 class=\"hvx-section-title\"\u003eImportant\u003c\/h3\u003e\n\u003cul style=\"margin: 0; padding-left: 18px;\" class=\"hvx-muted\"\u003e\n\u003cli\u003eProfessional installation is recommended.\u003c\/li\u003e\n\u003cli\u003eMatch line set sizes to the equipment: 3\/8\" liquid and 5\/8\" suction.\u003c\/li\u003e\n\u003cli\u003eVerify the dedicated circuit is sized per equipment MCA and local code.\u003c\/li\u003e\n\u003cli\u003eFor help choosing equipment, contact us: \u003ca href=\"https:\/\/hvacsupplies.com\/pages\/contact\" class=\"hvx-link\"\u003ehvacsupplies.com\/pages\/contact\u003c\/a\u003e • \u003ca href=\"tel:+18005438933\" class=\"hvx-link\"\u003e(800) 543-8933\u003c\/a\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"hvx-desc-card hvx-faq\"\u003e\n\u003ch3 class=\"hvx-section-title\"\u003eFAQs\u003c\/h3\u003e\n\u003cdetails\u003e\n\u003csummary\u003eWhat is the difference between RH and RSH cassettes?\u003c\/summary\u003e\n\u003cp class=\"hvx-muted\"\u003eRSH models add refrigerant leakage detection in addition to standard monitoring features.\u003c\/p\u003e\n\u003c\/details\u003e\n\u003cdetails\u003e\n\u003csummary\u003eWhat line set sizes are required for this 24K cassette?\u003c\/summary\u003e\n\u003cp class=\"hvx-muted\"\u003e3\/8\" liquid line and 5\/8\" suction (gas) line.\u003c\/p\u003e\n\u003c\/details\u003e\n\u003cdetails\u003e\n\u003csummary\u003eHow cold can the Hyper outdoor unit heat?\u003c\/summary\u003e\n\u003cp class=\"hvx-muted\"\u003eCH-RHP24-230VO supports heating operation down to -22°F ambient.\u003c\/p\u003e\n\u003c\/details\u003e\n\u003cdetails\u003e\n\u003csummary\u003eDoes the indoor cassette include a condensate pump?\u003c\/summary\u003e\n\u003cp class=\"hvx-muted\"\u003eYes. CH-RSH24MCT includes a built-in pump with float switch (20.9\" lift).\u003c\/p\u003e\n\u003c\/details\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e","brand":"Cooper\u0026Hunter","offers":[{"title":"No Installation","offer_id":42691015082027,"sku":"CH-RSH24MCT + CH-RHP24-230VO","price":2901.0,"currency_code":"USD","in_stock":true},{"title":"16FT","offer_id":42691015114795,"sku":"CH-RSH24MCT + CH-RHP24-230VO","price":3117.0,"currency_code":"USD","in_stock":true},{"title":"25FT","offer_id":42691015147563,"sku":"CH-RSH24MCT + CH-RHP24-230VO","price":3247.0,"currency_code":"USD","in_stock":true},{"title":"50FT","offer_id":42691015180331,"sku":"CH-RSH24MCT + CH-RHP24-230VO","price":3554.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0625\/5647\/1339\/files\/2-ZoneDuctlessMiniSplitAC_HeatPump48000BTU_26.png?v=1769199192"},{"product_id":"cooper-hunter-24-000-btu-pro-single-zone-four-way-ceiling-cassette-w-refrigerant-humidity-sensor-minisplit-heat-pump-system-r454b-230v","title":"Cooper\u0026Hunter 24,000 BTU Pro Single Zone Four-Way Ceiling Cassette w\/ Refrigerant \u0026 Humidity Sensor Minisplit Heat Pump System R454B 230V","description":"\u003cstyle\u003e\n    :root{--hvx-golden:#FAA819;--hvx-slate:#262626;--hvx-ivory:#F4F1E6;--hvx-border:#e2e0d5;--hvx-card-bg:#ffffff;}\n    .hvx-desc{background:var(--hvx-ivory);padding:18px;border-radius:18px;font-family:\"Articulat CF\",system-ui,-apple-system,Segoe UI,Roboto,Arial,sans-serif;color:#111;}\n    .hvx-desc-header{background:linear-gradient(120deg,var(--hvx-golden),var(--hvx-slate));border-radius:16px;padding:16px 16px 14px;color:#fff;margin-bottom:14px;}\n    .hvx-eyebrow{font-size:12px;letter-spacing:.12em;text-transform:uppercase;opacity:.9;margin:0 0 6px;}\n    .hvx-title{font-family:\"Anton\",Impact,Haettenschweiler,\"Arial Narrow Bold\",sans-serif;font-size:26px;line-height:1.05;margin:0;}\n    .hvx-desc-card{background:var(--hvx-card-bg);border:1px solid var(--hvx-border);border-radius:16px;padding:14px;margin:12px 0;box-shadow:0 10px 18px rgba(0,0,0,.06);}\n    .hvx-section-title{margin:0 0 10px;font-size:13px;letter-spacing:.12em;text-transform:uppercase;display:inline-block;padding-bottom:6px;position:relative;}\n    .hvx-section-title:after{content:\"\";position:absolute;left:0;bottom:0;height:3px;width:100%;border-radius:99px;background:linear-gradient(90deg,var(--hvx-golden),var(--hvx-slate));}\n    .hvx-badges{display:flex;flex-wrap:wrap;gap:8px;margin:6px 0 10px;}\n    .hvx-badge{display:inline-flex;align-items:center;gap:6px;padding:6px 10px;border-radius:999px;border:1px solid var(--hvx-border);background:#fff;font-size:12px;font-weight:600;}\n    .hvx-grid{display:grid;grid-template-columns:repeat(3,minmax(0,1fr));gap:10px;}\n    .hvx-kv{border:1px solid var(--hvx-border);border-radius:14px;padding:10px;background:#fff;}\n    .hvx-k{font-size:12px;letter-spacing:.08em;text-transform:uppercase;color:#333;margin:0 0 6px;}\n    .hvx-v{font-size:14px;font-weight:700;margin:0;}\n    .hvx-table-wrap{overflow:auto;border-radius:14px;border:1px solid var(--hvx-border);background:#fff;}\n    table.hvx-table{width:100%;border-collapse:collapse;min-width:520px;}\n    .hvx-table th,.hvx-table td{padding:10px 12px;border-bottom:1px solid var(--hvx-border);vertical-align:top;font-size:14px;}\n    .hvx-table th{background:rgba(250,168,25,.12);text-align:left;font-size:12px;letter-spacing:.1em;text-transform:uppercase;}\n    .hvx-table tr:last-child td{border-bottom:none;}\n    .hvx-link{color:#111;text-decoration:none;border-bottom:2px solid rgba(250,168,25,.7);}\n    .hvx-link:hover{border-bottom-color:#111;}\n    .hvx-faq details{border:1px solid var(--hvx-border);border-radius:14px;background:#fff;padding:10px 12px;margin:10px 0;}\n    .hvx-faq summary{cursor:pointer;font-weight:800;}\n    .hvx-muted{color:#333;margin:6px 0 0;}\n    @media (max-width:720px){.hvx-grid{grid-template-columns:1fr;}.hvx-title{font-size:24px;}}\n  \u003c\/style\u003e\n\u003cdiv class=\"hvx-desc\"\u003e\n\u003cdiv class=\"hvx-desc-header\"\u003e\n\u003cp class=\"hvx-eyebrow\"\u003eSingle Zone • 4-Way Ceiling Cassette • R454B • 208–230V\u003c\/p\u003e\n\u003ch2 class=\"hvx-title\"\u003eCooper\u0026amp;Hunter 24,000 BTU Pro Single Zone Four-Way Ceiling Cassette w\/ Refrigerant \u0026amp; Humidity Sensor Minisplit Heat Pump System R454B 230V\u003c\/h2\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"hvx-desc-card\"\u003e\n\u003ch3 class=\"hvx-section-title\"\u003eOverview\u003c\/h3\u003e\n\u003cp class=\"hvx-muted\"\u003eA 24K four-way ceiling cassette pairing designed for wide, even airflow with added system protection. The CH-RSH24MCT cassette includes refrigerant leakage detection plus humidity sensing and self-diagnosis features, and includes a built-in condensate pump. Pair it with the CH-RES24-230VO regular outdoor unit for efficient, dependable comfort.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"hvx-desc-card\"\u003e\n\u003ch3 class=\"hvx-section-title\"\u003eHighlights\u003c\/h3\u003e\n\u003cdiv class=\"hvx-badges\"\u003e\n\u003cspan class=\"hvx-badge\"\u003eR454B Refrigerant\u003c\/span\u003e \u003cspan class=\"hvx-badge\"\u003e360° Airflow Panel\u003c\/span\u003e \u003cspan class=\"hvx-badge\"\u003eLeak Detection (RSH)\u003c\/span\u003e \u003cspan class=\"hvx-badge\"\u003eHumidity Sensor\u003c\/span\u003e \u003cspan class=\"hvx-badge\"\u003eGoldFin Coil Coating\u003c\/span\u003e \u003cspan class=\"hvx-badge\"\u003eBuilt-In Condensate Pump\u003c\/span\u003e \u003cspan class=\"hvx-badge\"\u003eInverter Outdoor\u003c\/span\u003e\n\u003c\/div\u003e\n\u003cul class=\"hvx-muted\" style=\"margin: 0 0 10px; padding-left: 18px;\"\u003e\n\u003cli\u003eOmni-directional airflow and 360° panel helps distribute air evenly throughout the room.\u003c\/li\u003e\n\u003cli\u003eActivated carbon filtration support for fresher indoor air.\u003c\/li\u003e\n\u003cli\u003eRefrigerant leakage detection helps protect the system in abnormal conditions.\u003c\/li\u003e\n\u003cli\u003eAnti-cold-air heating behavior reduces drafts during heat mode.\u003c\/li\u003e\n\u003cli\u003eBuilt-in pump with float switch (20.9\" lift) for quiet condensate removal.\u003c\/li\u003e\n\u003cli\u003eRegular outdoor unit supports heating operation down to -13°F ambient.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cdiv class=\"hvx-grid\"\u003e\n\u003cdiv class=\"hvx-kv\"\u003e\n\u003cp class=\"hvx-k\"\u003eIndoor Model\u003c\/p\u003e\n\u003cp class=\"hvx-v\"\u003e\u003ca class=\"hvx-link\" href=\"https:\/\/hvacsupplies.com\/search?options%5Bprefix%5D=last\u0026amp;q=CH-RSH24MCT\"\u003eCH-RSH24MCT\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"hvx-kv\"\u003e\n\u003cp class=\"hvx-k\"\u003eOutdoor Model\u003c\/p\u003e\n\u003cp class=\"hvx-v\"\u003e\u003ca class=\"hvx-link\" href=\"https:\/\/hvacsupplies.com\/search?options%5Bprefix%5D=last\u0026amp;q=CH-RES24-230VO\"\u003eCH-RES24-230VO\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"hvx-kv\"\u003e\n\u003cp class=\"hvx-k\"\u003eLine Set Size\u003c\/p\u003e\n\u003cp class=\"hvx-v\"\u003e3\/8\" Liquid • 5\/8\" Gas\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"hvx-kv\"\u003e\n\u003cp class=\"hvx-k\"\u003eOutdoor SEER2\u003c\/p\u003e\n\u003cp class=\"hvx-v\"\u003e22\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"hvx-kv\"\u003e\n\u003cp class=\"hvx-k\"\u003eMax Line Length\u003c\/p\u003e\n\u003cp class=\"hvx-v\"\u003e164 ft\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"hvx-kv\"\u003e\n\u003cp class=\"hvx-k\"\u003eLow-Ambient Heating\u003c\/p\u003e\n\u003cp class=\"hvx-v\"\u003eDown to -13°F\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"hvx-desc-card\"\u003e\n\u003ch3 class=\"hvx-section-title\"\u003eWhat’s Included\u003c\/h3\u003e\n\u003cul class=\"hvx-muted\" style=\"margin: 0; padding-left: 18px;\"\u003e\n\u003cli\u003eIndoor 4-way ceiling cassette: CH-RSH24MCT\u003c\/li\u003e\n\u003cli\u003eOutdoor condenser: CH-RES24-230VO (Regular)\u003c\/li\u003e\n\u003cli\u003eRemote control (indoor control package)\u003c\/li\u003e\n\u003cli\u003eCeiling Cassette Panel\u003c\/li\u003e\n\u003cli\u003eBuilt-in condensate pump with float switch (indoor)\u003c\/li\u003e\n\u003cli\u003eSmart Kit capability for app control (setup required)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"hvx-desc-card\"\u003e\n\u003ch3 class=\"hvx-section-title\"\u003eIndoor Specs (CH-RSH24MCT)\u003c\/h3\u003e\n\u003cdiv class=\"hvx-table-wrap\"\u003e\n\u003ctable class=\"hvx-table\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eSpec\u003c\/th\u003e\n\u003cth\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRefrigerant Type\u003c\/td\u003e\n\u003ctd\u003eR454B\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSystem Type\u003c\/td\u003e\n\u003ctd\u003eSingle Zone\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBTU Rated\u003c\/td\u003e\n\u003ctd\u003e24,000\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower\u003c\/td\u003e\n\u003ctd\u003e208–230V • 1Ph • 60Hz (Voltage Range: 187–253V)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSEER2 \/ EER2\u003c\/td\u003e\n\u003ctd\u003e20.7 \/ 12\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDehumidification\u003c\/td\u003e\n\u003ctd\u003e4.99 pints\/day\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIndoor Airflow (CFM)\u003c\/td\u003e\n\u003ctd\u003e765.2 \/ 706.3 \/ 635.7 \/ 547.4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNoise (dB(A))\u003c\/td\u003e\n\u003ctd\u003e45 \/ 42.5 \/ 33.5 (H\/M\/L)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUnit Dimensions (W×D×H)\u003c\/td\u003e\n\u003ctd\u003e32.68 × 32.68 × 8.07 in\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNet \/ Gross Weight\u003c\/td\u003e\n\u003ctd\u003e47.18 \/ 59.08 lb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRefrigerant Piping\u003c\/td\u003e\n\u003ctd\u003e3\/8\" Liquid • 5\/8\" Gas\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDrain Pipe Diameter\u003c\/td\u003e\n\u003ctd\u003e1\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Range\u003c\/td\u003e\n\u003ctd\u003eCooling: 60–90°F • Heating: 32–86°F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMinimum Circuit Ampacity\u003c\/td\u003e\n\u003ctd\u003e3 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax Fuse\u003c\/td\u003e\n\u003ctd\u003e15 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"hvx-desc-card\"\u003e\n\u003ch3 class=\"hvx-section-title\"\u003eOutdoor Specs (CH-RES24-230VO)\u003c\/h3\u003e\n\u003cdiv class=\"hvx-table-wrap\"\u003e\n\u003ctable class=\"hvx-table\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eSpec\u003c\/th\u003e\n\u003cth\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRefrigerant Type\u003c\/td\u003e\n\u003ctd\u003eR454B\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSystem Type\u003c\/td\u003e\n\u003ctd\u003eSingle-zone unit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBTU Rated\u003c\/td\u003e\n\u003ctd\u003e24,000\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCooling Capacity (Min–Max)\u003c\/td\u003e\n\u003ctd\u003e24,000 (8,500–28,300) BTU\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHeating Capacity (Min–Max)\u003c\/td\u003e\n\u003ctd\u003e25,000 (11,800–35,100) BTU\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSEER2 \/ EER2\u003c\/td\u003e\n\u003ctd\u003e19 \/ 12.5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHSPF2 (Region IV \/ V)\u003c\/td\u003e\n\u003ctd\u003e11 \/ 8.5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCOP\u003c\/td\u003e\n\u003ctd\u003e3.64\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower\u003c\/td\u003e\n\u003ctd\u003e208–230V • 1Ph • 60Hz (Voltage Range: 187–253V)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax Pipe Length\u003c\/td\u003e\n\u003ctd\u003e164 ft\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax Height Difference\u003c\/td\u003e\n\u003ctd\u003e82 ft\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMinimum Circuit Ampacity\u003c\/td\u003e\n\u003ctd\u003e24 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax Fuse\u003c\/td\u003e\n\u003ctd\u003e25 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutdoor Airflow\u003c\/td\u003e\n\u003ctd\u003e2,236.7 CFM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutdoor Noise\u003c\/td\u003e\n\u003ctd\u003e60 dB(A)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUnit Dimensions (W×D×H)\u003c\/td\u003e\n\u003ctd\u003e37.24 × 16.14 × 31.89 in\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNet \/ Gross Weight\u003c\/td\u003e\n\u003ctd\u003e122.13 \/ 132.28 lb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAmbient Temperature\u003c\/td\u003e\n\u003ctd\u003eCooling: -13–122°F • Heating: -13–75°F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAdditional Charge\u003c\/td\u003e\n\u003ctd\u003e0.32 oz\/ft (3\/8\" liquid line)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"hvx-desc-card\"\u003e\n\u003ch3 class=\"hvx-section-title\"\u003eDocuments \u0026amp; Downloads\u003c\/h3\u003e\n\u003cul class=\"hvx-muted\" style=\"margin: 0; padding-left: 18px;\"\u003e\n\u003cli\u003e\u003ca class=\"hvx-link\" href=\"https:\/\/media.cooperandhunter.us\/4681\/CH-RES24-230VO_CH-RSH24MCT.pdf\"\u003eSubmittal Sheet: CH-RES24-230VO + CH-RSH24MCT\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca class=\"hvx-link\" href=\"https:\/\/media.cooperandhunter.us\/4159\/CH-RES24-230VO-%2B-CH-PRO24MASTWM-230VI.pdf\"\u003eSubmittal Sheet: CH-RES24-230VO + CH-PRO24MASTWM-230VI\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca class=\"hvx-link\" href=\"https:\/\/media.cooperandhunter.us\/4173\/CH-RES24-230VO-%2B-CH-RH24MASTWM-230VI.pdf\"\u003eSubmittal Sheet: CH-RES24-230VO + CH-RH24MASTWM-230VI\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca class=\"hvx-link\" href=\"https:\/\/media.cooperandhunter.us\/4212\/CH-RES24-230VO-%2B-CH-RS24MDT-HS.pdf\"\u003eSubmittal Sheet: CH-RES24-230VO + CH-RS24MDT-HS\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca class=\"hvx-link\" href=\"https:\/\/media.cooperandhunter.us\/4626\/CH-RES24-230VO_CH-RSH24MFC.pdf\"\u003eSubmittal Sheet: CH-RES24-230VO + CH-RSH24MFC\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca class=\"hvx-link\" href=\"https:\/\/media.cooperandhunter.us\/4680\/CH-RES24-230VO_CH-RH24MCT.pdf\"\u003eSubmittal Sheet: CH-RES24-230VO + CH-RH24MCT\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca class=\"hvx-link\" href=\"https:\/\/media.cooperandhunter.us\/4118\/Installation-Manual-R454B-Outdoor-units--.pdf\"\u003eOutdoor Units Installation Manual (R454B)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca class=\"hvx-link\" href=\"https:\/\/media.cooperandhunter.us\/4200\/SlimDuct-Leaflet-R454B.pdf\"\u003eSlimDuct Leaflet (R454B)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca class=\"hvx-link\" href=\"https:\/\/media.cooperandhunter.us\/4654\/Installation-manual-R454B-Ceiling-cassette_compressed.pdf\"\u003eCeiling Cassette Installation Manual (R454B)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca class=\"hvx-link\" href=\"https:\/\/media.cooperandhunter.us\/4655\/Owners_-manual-R454B-Ceiling-cassette_compressed.pdf\"\u003eCeiling Cassette Owner’s Manual (R454B)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca class=\"hvx-link\" href=\"https:\/\/media.cooperandhunter.us\/3309\/120N--uses-and-installation-manual.pdf\"\u003e120N Wire Controller — Uses \u0026amp; Installation Manual\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca class=\"hvx-link\" href=\"https:\/\/media.cooperandhunter.us\/3198\/MultiZone-Combination-HYPER.pdf\"\u003eMultiZone Combination Guide — Hyper\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca class=\"hvx-link\" href=\"https:\/\/media.cooperandhunter.us\/3199\/MultiZone-Combination-Regular.pdf\"\u003eMultiZone Combination Guide — Regular\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"hvx-desc-card\"\u003e\n\u003ch3 class=\"hvx-section-title\"\u003eImportant\u003c\/h3\u003e\n\u003cul class=\"hvx-muted\" style=\"margin: 0; padding-left: 18px;\"\u003e\n\u003cli\u003eProfessional installation is recommended.\u003c\/li\u003e\n\u003cli\u003eMatch line set sizes to the equipment: 3\/8\" liquid and 5\/8\" suction.\u003c\/li\u003e\n\u003cli\u003eVerify the dedicated circuit is sized per equipment MCA and local code.\u003c\/li\u003e\n\u003cli\u003eFor help choosing equipment, contact us: \u003ca class=\"hvx-link\" href=\"https:\/\/hvacsupplies.com\/pages\/contact\"\u003ehvacsupplies.com\/pages\/contact\u003c\/a\u003e • \u003ca class=\"hvx-link\" href=\"tel:+18005438933\"\u003e(800) 543-8933\u003c\/a\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"hvx-desc-card hvx-faq\"\u003e\n\u003ch3 class=\"hvx-section-title\"\u003eFAQs\u003c\/h3\u003e\n\u003cdetails\u003e\n\u003csummary\u003eWhat is the difference between RH and RSH cassettes?\u003c\/summary\u003e\n\u003cp class=\"hvx-muted\"\u003eRSH models add refrigerant leakage detection in addition to standard monitoring features.\u003c\/p\u003e\n\u003c\/details\u003e\n\u003cdetails\u003e\n\u003csummary\u003eWhat line set sizes are required for this 24K cassette?\u003c\/summary\u003e\n\u003cp class=\"hvx-muted\"\u003e3\/8\" liquid line and 5\/8\" suction (gas) line.\u003c\/p\u003e\n\u003c\/details\u003e\n\u003cdetails\u003e\n\u003csummary\u003eHow cold can the regular outdoor unit operate in heating?\u003c\/summary\u003e\n\u003cp class=\"hvx-muted\"\u003eCH-RES24-230VO supports heating operation down to -13°F ambient.\u003c\/p\u003e\n\u003c\/details\u003e\n\u003cdetails\u003e\n\u003csummary\u003eDoes the indoor cassette include a condensate pump?\u003c\/summary\u003e\n\u003cp class=\"hvx-muted\"\u003eYes. CH-RSH24MCT includes a built-in pump with float switch (20.9\" lift).\u003c\/p\u003e\n\u003c\/details\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e","brand":"Cooper\u0026Hunter","offers":[{"title":"No Installation","offer_id":42691017572395,"sku":"CH-RSH24MCT + CH-RES24-230VO","price":2344.0,"currency_code":"USD","in_stock":true},{"title":"16FT","offer_id":42691017605163,"sku":"CH-RSH24MCT + CH-RES24-230VO","price":2560.0,"currency_code":"USD","in_stock":true},{"title":"25FT","offer_id":42691017637931,"sku":"CH-RSH24MCT + CH-RES24-230VO","price":2690.0,"currency_code":"USD","in_stock":true},{"title":"50FT","offer_id":42691017670699,"sku":"CH-RSH24MCT + CH-RES24-230VO","price":2997.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0625\/5647\/1339\/files\/FourWay_Regular_Product_Hero_48_33b3a9f5-7a1c-442f-a881-e51e604eb6c3.png?v=1769199174"},{"product_id":"cooper-hunter-24-000-btu-hyper-single-zone-four-way-ceiling-cassette-w-humidity-sensor-minisplit-heat-pump-system-r454b-230v","title":"Cooper\u0026Hunter 24,000 BTU Hyper Single Zone Four-Way Ceiling Cassette w\/ Humidity Sensor Minisplit Heat Pump System R454B 230V","description":"\u003cstyle\u003e\n    :root{--hvx-golden:#FAA819;--hvx-slate:#262626;--hvx-ivory:#F4F1E6;--hvx-border:#e2e0d5;--hvx-card-bg:#ffffff;}\n    .hvx-desc{background:var(--hvx-ivory);padding:18px;border-radius:18px;font-family:\"Articulat CF\",system-ui,-apple-system,Segoe UI,Roboto,Arial,sans-serif;color:#111;}\n    .hvx-desc-header{background:linear-gradient(120deg,var(--hvx-golden),var(--hvx-slate));border-radius:16px;padding:16px 16px 14px;color:#fff;margin-bottom:14px;}\n    .hvx-eyebrow{font-size:12px;letter-spacing:.12em;text-transform:uppercase;opacity:.9;margin:0 0 6px;}\n    .hvx-title{font-family:\"Anton\",Impact,Haettenschweiler,\"Arial Narrow Bold\",sans-serif;font-size:26px;line-height:1.05;margin:0;}\n    .hvx-desc-card{background:var(--hvx-card-bg);border:1px solid var(--hvx-border);border-radius:16px;padding:14px;margin:12px 0;box-shadow:0 10px 18px rgba(0,0,0,.06);}\n    .hvx-section-title{margin:0 0 10px;font-size:13px;letter-spacing:.12em;text-transform:uppercase;display:inline-block;padding-bottom:6px;position:relative;}\n    .hvx-section-title:after{content:\"\";position:absolute;left:0;bottom:0;height:3px;width:100%;border-radius:99px;background:linear-gradient(90deg,var(--hvx-golden),var(--hvx-slate));}\n    .hvx-badges{display:flex;flex-wrap:wrap;gap:8px;margin:6px 0 10px;}\n    .hvx-badge{display:inline-flex;align-items:center;gap:6px;padding:6px 10px;border-radius:999px;border:1px solid var(--hvx-border);background:#fff;font-size:12px;font-weight:600;}\n    .hvx-grid{display:grid;grid-template-columns:repeat(3,minmax(0,1fr));gap:10px;}\n    .hvx-kv{border:1px solid var(--hvx-border);border-radius:14px;padding:10px;background:#fff;}\n    .hvx-k{font-size:12px;letter-spacing:.08em;text-transform:uppercase;color:#333;margin:0 0 6px;}\n    .hvx-v{font-size:14px;font-weight:700;margin:0;}\n    .hvx-table-wrap{overflow:auto;border-radius:14px;border:1px solid var(--hvx-border);background:#fff;}\n    table.hvx-table{width:100%;border-collapse:collapse;min-width:520px;}\n    .hvx-table th,.hvx-table td{padding:10px 12px;border-bottom:1px solid var(--hvx-border);vertical-align:top;font-size:14px;}\n    .hvx-table th{background:rgba(250,168,25,.12);text-align:left;font-size:12px;letter-spacing:.1em;text-transform:uppercase;}\n    .hvx-table tr:last-child td{border-bottom:none;}\n    .hvx-link{color:#111;text-decoration:none;border-bottom:2px solid rgba(250,168,25,.7);}\n    .hvx-link:hover{border-bottom-color:#111;}\n    .hvx-faq details{border:1px solid var(--hvx-border);border-radius:14px;background:#fff;padding:10px 12px;margin:10px 0;}\n    .hvx-faq summary{cursor:pointer;font-weight:800;}\n    .hvx-muted{color:#333;margin:6px 0 0;}\n    @media (max-width:720px){.hvx-grid{grid-template-columns:1fr;}.hvx-title{font-size:24px;}}\n  \u003c\/style\u003e\n\u003cdiv class=\"hvx-desc\"\u003e\n\u003cdiv class=\"hvx-desc-header\"\u003e\n\u003cp class=\"hvx-eyebrow\"\u003eSingle Zone • 4-Way Ceiling Cassette • R454B • 208–230V\u003c\/p\u003e\n\u003ch2 class=\"hvx-title\"\u003eCooper\u0026amp;Hunter 24,000 BTU Hyper Single Zone Four-Way Ceiling Cassette w\/ Humidity Sensor Minisplit Heat Pump System R454B 230V\u003c\/h2\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"hvx-desc-card\"\u003e\n\u003ch3 class=\"hvx-section-title\"\u003eOverview\u003c\/h3\u003e\n\u003cp class=\"hvx-muted\"\u003eA 24K four-way ceiling cassette pairing designed for wide, even air distribution and efficient inverter performance. The CH-RH24MCT cassette features omni-directional airflow with a 360° air flow panel and a built-in condensate pump. Pair it with the CH-RHP24-230VO Hyper outdoor unit for powerful heating performance down to -22°F.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"hvx-desc-card\"\u003e\n\u003ch3 class=\"hvx-section-title\"\u003eHighlights\u003c\/h3\u003e\n\u003cdiv class=\"hvx-badges\"\u003e\n\u003cspan class=\"hvx-badge\"\u003eR454B Refrigerant\u003c\/span\u003e \u003cspan class=\"hvx-badge\"\u003e360° Airflow Panel\u003c\/span\u003e \u003cspan class=\"hvx-badge\"\u003eHumidity Sensor\u003c\/span\u003e \u003cspan class=\"hvx-badge\"\u003eGoldFin Coil Coating\u003c\/span\u003e \u003cspan class=\"hvx-badge\"\u003eBuilt-In Condensate Pump\u003c\/span\u003e \u003cspan class=\"hvx-badge\"\u003eHyper Heating Outdoor\u003c\/span\u003e\n\u003c\/div\u003e\n\u003cul style=\"margin: 0 0 10px; padding-left: 18px;\" class=\"hvx-muted\"\u003e\n\u003cli\u003eOmni-directional airflow and 360° panel helps distribute air evenly throughout the room.\u003c\/li\u003e\n\u003cli\u003eActivated carbon filtration support for fresher indoor air.\u003c\/li\u003e\n\u003cli\u003eAnti-cold-air heating behavior reduces chilly drafts during heat mode.\u003c\/li\u003e\n\u003cli\u003eBuilt-in pump with float switch (20.9\" lift) for quiet condensate removal.\u003c\/li\u003e\n\u003cli\u003eTurbo operation, sleep mode, and multiple fan speeds for comfort tuning.\u003c\/li\u003e\n\u003cli\u003eHyper outdoor unit supports heating operation down to -22°F ambient.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cdiv class=\"hvx-grid\"\u003e\n\u003cdiv class=\"hvx-kv\"\u003e\n\u003cp class=\"hvx-k\"\u003eIndoor Model\u003c\/p\u003e\n\u003cp class=\"hvx-v\"\u003e\u003ca href=\"https:\/\/hvacsupplies.com\/search?options%5Bprefix%5D=last\u0026amp;q=CH-RH24MCT\" class=\"hvx-link\"\u003eCH-RH24MCT\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"hvx-kv\"\u003e\n\u003cp class=\"hvx-k\"\u003eOutdoor Model\u003c\/p\u003e\n\u003cp class=\"hvx-v\"\u003e\u003ca href=\"https:\/\/hvacsupplies.com\/search?options%5Bprefix%5D=last\u0026amp;q=CH-RHP24-230VO\" class=\"hvx-link\"\u003eCH-RHP24-230VO\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"hvx-kv\"\u003e\n\u003cp class=\"hvx-k\"\u003eLine Set Size\u003c\/p\u003e\n\u003cp class=\"hvx-v\"\u003e3\/8\" Liquid • 5\/8\" Gas\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"hvx-kv\"\u003e\n\u003cp class=\"hvx-k\"\u003ePower\u003c\/p\u003e\n\u003cp class=\"hvx-v\"\u003e208–230V • 1Ph • 60Hz\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"hvx-kv\"\u003e\n\u003cp class=\"hvx-k\"\u003eMax Line Length\u003c\/p\u003e\n\u003cp class=\"hvx-v\"\u003e164 ft\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"hvx-kv\"\u003e\n\u003cp class=\"hvx-k\"\u003eLow-Ambient Heating\u003c\/p\u003e\n\u003cp class=\"hvx-v\"\u003eDown to -22°F\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"hvx-desc-card\"\u003e\n\u003ch3 class=\"hvx-section-title\"\u003eWhat’s Included\u003c\/h3\u003e\n\u003cul style=\"margin: 0; padding-left: 18px;\" class=\"hvx-muted\"\u003e\n\u003cli\u003eIndoor 4-way ceiling cassette: CH-RH24MCT\u003c\/li\u003e\n\u003cli\u003eOutdoor condenser: CH-RHP24-230VO (Hyper)\u003c\/li\u003e\n\u003cli\u003eRemote control (indoor control package)\u003c\/li\u003e\n\u003cli\u003eCeiling Cassette Panel\u003c\/li\u003e\n\u003cli\u003eBuilt-in condensate pump with float switch (indoor)\u003c\/li\u003e\n\u003cli\u003eSmart Kit capability for app control (setup required)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"hvx-desc-card\"\u003e\n\u003ch3 class=\"hvx-section-title\"\u003eIndoor Specs (CH-RH24MCT)\u003c\/h3\u003e\n\u003cdiv class=\"hvx-table-wrap\"\u003e\n\u003ctable class=\"hvx-table\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eSpec\u003c\/th\u003e\n\u003cth\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRefrigerant Type\u003c\/td\u003e\n\u003ctd\u003eR454B\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSystem Type\u003c\/td\u003e\n\u003ctd\u003eSingle Zone\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBTU Rated\u003c\/td\u003e\n\u003ctd\u003e24,000\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower\u003c\/td\u003e\n\u003ctd\u003e208–230V • 1Ph • 60Hz (Voltage Range: 187–253V)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSEER2 \/ EER2\u003c\/td\u003e\n\u003ctd\u003e20.7 \/ 12\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDehumidification\u003c\/td\u003e\n\u003ctd\u003e4.99 pints\/day\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIndoor Airflow (CFM)\u003c\/td\u003e\n\u003ctd\u003e765.2 \/ 706.3 \/ 635.7 \/ 547.4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNoise (dB(A))\u003c\/td\u003e\n\u003ctd\u003e45 \/ 42.5 \/ 33.5 (H\/M\/L)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUnit Dimensions (W×D×H)\u003c\/td\u003e\n\u003ctd\u003e32.68 × 32.68 × 8.07 in\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNet \/ Gross Weight\u003c\/td\u003e\n\u003ctd\u003e47.18 \/ 59.08 lb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRefrigerant Piping\u003c\/td\u003e\n\u003ctd\u003e3\/8\" Liquid • 5\/8\" Gas\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDrain Pipe Diameter\u003c\/td\u003e\n\u003ctd\u003e1\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Range\u003c\/td\u003e\n\u003ctd\u003eCooling: 60–90°F • Heating: 32–86°F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMinimum Circuit Ampacity\u003c\/td\u003e\n\u003ctd\u003e3 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax Fuse\u003c\/td\u003e\n\u003ctd\u003e15 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"hvx-desc-card\"\u003e\n\u003ch3 class=\"hvx-section-title\"\u003eOutdoor Specs (CH-RHP24-230VO)\u003c\/h3\u003e\n\u003cdiv class=\"hvx-table-wrap\"\u003e\n\u003ctable class=\"hvx-table\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eSpec\u003c\/th\u003e\n\u003cth\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRefrigerant Type\u003c\/td\u003e\n\u003ctd\u003eR454B\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBTU Rated\u003c\/td\u003e\n\u003ctd\u003e24,000\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCooling Capacity (Min–Max)\u003c\/td\u003e\n\u003ctd\u003e24,000 (12,600–27,900) BTU\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHeating Capacity (Min–Max)\u003c\/td\u003e\n\u003ctd\u003e29,000 (11,800–29,700) BTU\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHSPF2 (Region IV \/ V)\u003c\/td\u003e\n\u003ctd\u003e13.5 \/ 9.8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCOP\u003c\/td\u003e\n\u003ctd\u003e3.42\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower\u003c\/td\u003e\n\u003ctd\u003e208–230V • 1Ph • 60Hz (Voltage Range: 187–253V)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax Pipe Length\u003c\/td\u003e\n\u003ctd\u003e164 ft\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax Height Difference\u003c\/td\u003e\n\u003ctd\u003e82 ft\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMinimum Circuit Ampacity\u003c\/td\u003e\n\u003ctd\u003e24.9 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax Fuse\u003c\/td\u003e\n\u003ctd\u003e25 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutdoor Airflow\u003c\/td\u003e\n\u003ctd\u003e2,235.3 CFM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutdoor Noise\u003c\/td\u003e\n\u003ctd\u003e61.5 dB(A)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUnit Dimensions (W×D×H)\u003c\/td\u003e\n\u003ctd\u003e37.24 × 16.14 × 31.89 in\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNet \/ Gross Weight\u003c\/td\u003e\n\u003ctd\u003e130.29 \/ 141.31 lb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAmbient Temperature\u003c\/td\u003e\n\u003ctd\u003eCooling: -22–122°F • Heating: -22–75°F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAdditional Charge\u003c\/td\u003e\n\u003ctd\u003e0.32 oz\/ft (3\/8\" liquid line)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"hvx-desc-card\"\u003e\n\u003ch3 class=\"hvx-section-title\"\u003eDocuments \u0026amp; Downloads\u003c\/h3\u003e\n\u003cul style=\"margin: 0; padding-left: 18px;\" class=\"hvx-muted\"\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/media.cooperandhunter.us\/4688\/CH-RHP24-230VO_CH-RH24MCT.pdf\" class=\"hvx-link\"\u003eSubmittal Sheet: CH-RHP24-230VO + CH-RH24MCT\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/media.cooperandhunter.us\/3959\/CH-RHP24-230VO-%2B-CH-RS24MAHU.pdf\" class=\"hvx-link\"\u003eSubmittal Sheet: CH-RHP24-230VO + CH-RS24MAHU\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/media.cooperandhunter.us\/4160\/CH-RHP24-230VO-%2B-CH-PRO24MASTWM-230VI.pdf\" class=\"hvx-link\"\u003eSubmittal Sheet: CH-RHP24-230VO + CH-PRO24MASTWM-230VI\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/media.cooperandhunter.us\/4174\/CH-RHP24-230VO-%2B-CH-RH24MASTWM-230VI.pdf\" class=\"hvx-link\"\u003eSubmittal Sheet: CH-RHP24-230VO + CH-RH24MASTWM-230VI\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/media.cooperandhunter.us\/4205\/CH-RHP24-230VO-%2B-CH-RS24MDT-HS.pdf\" class=\"hvx-link\"\u003eSubmittal Sheet: CH-RHP24-230VO + CH-RS24MDT-HS\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/media.cooperandhunter.us\/4631\/CH-RHP24-230VO_CH-RSH24MFC.pdf\" class=\"hvx-link\"\u003eSubmittal Sheet: CH-RHP24-230VO + CH-RSH24MFC\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/media.cooperandhunter.us\/4118\/Installation-Manual-R454B-Outdoor-units--.pdf\" class=\"hvx-link\"\u003eOutdoor Units Installation Manual (R454B)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/media.cooperandhunter.us\/4200\/SlimDuct-Leaflet-R454B.pdf\" class=\"hvx-link\"\u003eSlimDuct Leaflet (R454B)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/media.cooperandhunter.us\/4654\/Installation-manual-R454B-Ceiling-cassette_compressed.pdf\" class=\"hvx-link\"\u003eCeiling Cassette Installation Manual (R454B)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/media.cooperandhunter.us\/4655\/Owners_-manual-R454B-Ceiling-cassette_compressed.pdf\" class=\"hvx-link\"\u003eCeiling Cassette Owner’s Manual (R454B)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/media.cooperandhunter.us\/3309\/120N--uses-and-installation-manual.pdf\" class=\"hvx-link\"\u003e120N Wire Controller — Uses \u0026amp; Installation Manual\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/media.cooperandhunter.us\/3198\/MultiZone-Combination-HYPER.pdf\" class=\"hvx-link\"\u003eMultiZone Combination Guide — Hyper\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/media.cooperandhunter.us\/3199\/MultiZone-Combination-Regular.pdf\" class=\"hvx-link\"\u003eMultiZone Combination Guide — Regular\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"hvx-desc-card\"\u003e\n\u003ch3 class=\"hvx-section-title\"\u003eImportant\u003c\/h3\u003e\n\u003cul style=\"margin: 0; padding-left: 18px;\" class=\"hvx-muted\"\u003e\n\u003cli\u003eProfessional installation is recommended.\u003c\/li\u003e\n\u003cli\u003eMatch line set sizes to the equipment: 3\/8\" liquid and 5\/8\" suction.\u003c\/li\u003e\n\u003cli\u003eVerify the dedicated circuit is sized per equipment MCA and local code.\u003c\/li\u003e\n\u003cli\u003eFor help choosing equipment, contact us: \u003ca href=\"https:\/\/hvacsupplies.com\/pages\/contact\" class=\"hvx-link\"\u003ehvacsupplies.com\/pages\/contact\u003c\/a\u003e • \u003ca href=\"tel:+18005438933\" class=\"hvx-link\"\u003e(800) 543-8933\u003c\/a\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"hvx-desc-card hvx-faq\"\u003e\n\u003ch3 class=\"hvx-section-title\"\u003eFAQs\u003c\/h3\u003e\n\u003cdetails\u003e\n\u003csummary\u003eDoes the indoor cassette include a condensate pump?\u003c\/summary\u003e\n\u003cp class=\"hvx-muted\"\u003eYes. CH-RH24MCT includes a built-in pump with float switch (20.9\" lift).\u003c\/p\u003e\n\u003c\/details\u003e\n\u003cdetails\u003e\n\u003csummary\u003eWhat line set sizes are required for this 24K cassette?\u003c\/summary\u003e\n\u003cp class=\"hvx-muted\"\u003e3\/8\" liquid line and 5\/8\" suction (gas) line.\u003c\/p\u003e\n\u003c\/details\u003e\n\u003cdetails\u003e\n\u003csummary\u003eHow cold can the Hyper outdoor unit heat?\u003c\/summary\u003e\n\u003cp class=\"hvx-muted\"\u003eCH-RHP24-230VO supports heating operation down to -22°F ambient.\u003c\/p\u003e\n\u003c\/details\u003e\n\u003cdetails\u003e\n\u003csummary\u003eCan I control the system with an app?\u003c\/summary\u003e\n\u003cp class=\"hvx-muted\"\u003eSmart Kit capability supports app control through the C\u0026amp;H platform after setup.\u003c\/p\u003e\n\u003c\/details\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e","brand":"Cooper\u0026Hunter","offers":[{"title":"No Installation","offer_id":42691020685355,"sku":"CH-RH24MCT + CH-RHP24-230VO","price":2812.0,"currency_code":"USD","in_stock":true},{"title":"16FT","offer_id":42691020718123,"sku":"CH-RH24MCT + CH-RHP24-230VO","price":3028.0,"currency_code":"USD","in_stock":true},{"title":"25FT","offer_id":42691020750891,"sku":"CH-RH24MCT + CH-RHP24-230VO","price":3158.0,"currency_code":"USD","in_stock":true},{"title":"50FT","offer_id":42691020783659,"sku":"CH-RH24MCT + CH-RHP24-230VO","price":3464.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0625\/5647\/1339\/files\/2-ZoneDuctlessMiniSplitAC_HeatPump48000BTU_26.png?v=1769199192"},{"product_id":"cooper-hunter-24-000-btu-single-zone-four-way-ceiling-cassette-w-humidity-sensor-minisplit-heat-pump-system-r454b-230v","title":"Cooper\u0026Hunter 24,000 BTU Single Zone Four-Way Ceiling Cassette w\/ Humidity Sensor Minisplit Heat Pump System R454B 230V","description":"\u003cstyle\u003e\n    :root{--hvx-golden:#FAA819;--hvx-slate:#262626;--hvx-ivory:#F4F1E6;--hvx-border:#e2e0d5;--hvx-card-bg:#ffffff;}\n    .hvx-desc{background:var(--hvx-ivory);padding:18px;border-radius:18px;font-family:\"Articulat CF\",system-ui,-apple-system,Segoe UI,Roboto,Arial,sans-serif;color:#111;}\n    .hvx-desc-header{background:linear-gradient(120deg,var(--hvx-golden),var(--hvx-slate));border-radius:16px;padding:16px 16px 14px;color:#fff;margin-bottom:14px;}\n    .hvx-eyebrow{font-size:12px;letter-spacing:.12em;text-transform:uppercase;opacity:.9;margin:0 0 6px;}\n    .hvx-title{font-family:\"Anton\",Impact,Haettenschweiler,\"Arial Narrow Bold\",sans-serif;font-size:26px;line-height:1.05;margin:0;}\n    .hvx-desc-card{background:var(--hvx-card-bg);border:1px solid var(--hvx-border);border-radius:16px;padding:14px;margin:12px 0;box-shadow:0 10px 18px rgba(0,0,0,.06);}\n    .hvx-section-title{margin:0 0 10px;font-size:13px;letter-spacing:.12em;text-transform:uppercase;display:inline-block;padding-bottom:6px;position:relative;}\n    .hvx-section-title:after{content:\"\";position:absolute;left:0;bottom:0;height:3px;width:100%;border-radius:99px;background:linear-gradient(90deg,var(--hvx-golden),var(--hvx-slate));}\n    .hvx-badges{display:flex;flex-wrap:wrap;gap:8px;margin:6px 0 10px;}\n    .hvx-badge{display:inline-flex;align-items:center;gap:6px;padding:6px 10px;border-radius:999px;border:1px solid var(--hvx-border);background:#fff;font-size:12px;font-weight:600;}\n    .hvx-grid{display:grid;grid-template-columns:repeat(3,minmax(0,1fr));gap:10px;}\n    .hvx-kv{border:1px solid var(--hvx-border);border-radius:14px;padding:10px;background:#fff;}\n    .hvx-k{font-size:12px;letter-spacing:.08em;text-transform:uppercase;color:#333;margin:0 0 6px;}\n    .hvx-v{font-size:14px;font-weight:700;margin:0;}\n    .hvx-table-wrap{overflow:auto;border-radius:14px;border:1px solid var(--hvx-border);background:#fff;}\n    table.hvx-table{width:100%;border-collapse:collapse;min-width:520px;}\n    .hvx-table th,.hvx-table td{padding:10px 12px;border-bottom:1px solid var(--hvx-border);vertical-align:top;font-size:14px;}\n    .hvx-table th{background:rgba(250,168,25,.12);text-align:left;font-size:12px;letter-spacing:.1em;text-transform:uppercase;}\n    .hvx-table tr:last-child td{border-bottom:none;}\n    .hvx-link{color:#111;text-decoration:none;border-bottom:2px solid rgba(250,168,25,.7);}\n    .hvx-link:hover{border-bottom-color:#111;}\n    .hvx-faq details{border:1px solid var(--hvx-border);border-radius:14px;background:#fff;padding:10px 12px;margin:10px 0;}\n    .hvx-faq summary{cursor:pointer;font-weight:800;}\n    .hvx-muted{color:#333;margin:6px 0 0;}\n    @media (max-width:720px){.hvx-grid{grid-template-columns:1fr;}.hvx-title{font-size:24px;}}\n  \u003c\/style\u003e\n\u003cdiv class=\"hvx-desc\"\u003e\n\u003cdiv class=\"hvx-desc-header\"\u003e\n\u003cp class=\"hvx-eyebrow\"\u003eSingle Zone • 4-Way Ceiling Cassette • R454B • 208–230V\u003c\/p\u003e\n\u003ch2 class=\"hvx-title\"\u003eCooper\u0026amp;Hunter 24,000 BTU Single Zone Four-Way Ceiling Cassette w\/ Humidity Sensor Minisplit Heat Pump System R454B 230V\u003c\/h2\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"hvx-desc-card\"\u003e\n\u003ch3 class=\"hvx-section-title\"\u003eOverview\u003c\/h3\u003e\n\u003cp class=\"hvx-muted\"\u003eA 24K four-way ceiling cassette pairing designed for wide, even air distribution and efficient inverter operation. The CH-RH24MCT cassette features omni-directional airflow with a 360° air flow panel and a built-in condensate pump. Pair it with the CH-RES24-230VO regular outdoor unit for efficient, dependable comfort.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"hvx-desc-card\"\u003e\n\u003ch3 class=\"hvx-section-title\"\u003eHighlights\u003c\/h3\u003e\n\u003cdiv class=\"hvx-badges\"\u003e\n\u003cspan class=\"hvx-badge\"\u003eR454B Refrigerant\u003c\/span\u003e \u003cspan class=\"hvx-badge\"\u003e360° Airflow Panel\u003c\/span\u003e \u003cspan class=\"hvx-badge\"\u003eHumidity Sensor\u003c\/span\u003e \u003cspan class=\"hvx-badge\"\u003eGoldFin Coil Coating\u003c\/span\u003e \u003cspan class=\"hvx-badge\"\u003eBuilt-In Condensate Pump\u003c\/span\u003e \u003cspan class=\"hvx-badge\"\u003eInverter Outdoor\u003c\/span\u003e\n\u003c\/div\u003e\n\u003cul class=\"hvx-muted\" style=\"margin: 0 0 10px; padding-left: 18px;\"\u003e\n\u003cli\u003eOmni-directional airflow and 360° panel helps distribute air evenly throughout the room.\u003c\/li\u003e\n\u003cli\u003eActivated carbon filtration support for fresher indoor air.\u003c\/li\u003e\n\u003cli\u003eAnti-cold-air heating behavior reduces drafts during heat mode.\u003c\/li\u003e\n\u003cli\u003eBuilt-in pump with float switch (20.9\" lift) for quiet condensate removal.\u003c\/li\u003e\n\u003cli\u003eTurbo operation, sleep mode, and multiple fan speeds for comfort tuning.\u003c\/li\u003e\n\u003cli\u003eRegular outdoor unit supports heating operation down to -13°F ambient.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cdiv class=\"hvx-grid\"\u003e\n\u003cdiv class=\"hvx-kv\"\u003e\n\u003cp class=\"hvx-k\"\u003eIndoor Model\u003c\/p\u003e\n\u003cp class=\"hvx-v\"\u003e\u003ca class=\"hvx-link\" href=\"https:\/\/hvacsupplies.com\/search?options%5Bprefix%5D=last\u0026amp;q=CH-RH24MCT\"\u003eCH-RH24MCT\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"hvx-kv\"\u003e\n\u003cp class=\"hvx-k\"\u003eOutdoor Model\u003c\/p\u003e\n\u003cp class=\"hvx-v\"\u003e\u003ca class=\"hvx-link\" href=\"https:\/\/hvacsupplies.com\/search?options%5Bprefix%5D=last\u0026amp;q=CH-RES24-230VO\"\u003eCH-RES24-230VO\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"hvx-kv\"\u003e\n\u003cp class=\"hvx-k\"\u003eLine Set Size\u003c\/p\u003e\n\u003cp class=\"hvx-v\"\u003e3\/8\" Liquid • 5\/8\" Gas\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"hvx-kv\"\u003e\n\u003cp class=\"hvx-k\"\u003eOutdoor SEER2\u003c\/p\u003e\n\u003cp class=\"hvx-v\"\u003e22\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"hvx-kv\"\u003e\n\u003cp class=\"hvx-k\"\u003eMax Line Length\u003c\/p\u003e\n\u003cp class=\"hvx-v\"\u003e164 ft\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"hvx-kv\"\u003e\n\u003cp class=\"hvx-k\"\u003eLow-Ambient Heating\u003c\/p\u003e\n\u003cp class=\"hvx-v\"\u003eDown to -13°F\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"hvx-desc-card\"\u003e\n\u003ch3 class=\"hvx-section-title\"\u003eWhat’s Included\u003c\/h3\u003e\n\u003cul class=\"hvx-muted\" style=\"margin: 0; padding-left: 18px;\"\u003e\n\u003cli\u003eIndoor 4-way ceiling cassette: CH-RH24MCT\u003c\/li\u003e\n\u003cli\u003eOutdoor condenser: CH-RES24-230VO (Regular)\u003c\/li\u003e\n\u003cli\u003eRemote control (indoor control package)\u003c\/li\u003e\n\u003cli\u003eCeiling Cassette Panel\u003c\/li\u003e\n\u003cli\u003eBuilt-in condensate pump with float switch (indoor)\u003c\/li\u003e\n\u003cli\u003eSmart Kit capability for app control (setup required)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"hvx-desc-card\"\u003e\n\u003ch3 class=\"hvx-section-title\"\u003eIndoor Specs (CH-RH24MCT)\u003c\/h3\u003e\n\u003cdiv class=\"hvx-table-wrap\"\u003e\n\u003ctable class=\"hvx-table\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eSpec\u003c\/th\u003e\n\u003cth\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRefrigerant Type\u003c\/td\u003e\n\u003ctd\u003eR454B\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSystem Type\u003c\/td\u003e\n\u003ctd\u003eSingle Zone\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBTU Rated\u003c\/td\u003e\n\u003ctd\u003e24,000\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower\u003c\/td\u003e\n\u003ctd\u003e208–230V • 1Ph • 60Hz (Voltage Range: 187–253V)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSEER2 \/ EER2\u003c\/td\u003e\n\u003ctd\u003e20.7 \/ 12\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDehumidification\u003c\/td\u003e\n\u003ctd\u003e4.99 pints\/day\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIndoor Airflow (CFM)\u003c\/td\u003e\n\u003ctd\u003e765.2 \/ 706.3 \/ 635.7 \/ 547.4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNoise (dB(A))\u003c\/td\u003e\n\u003ctd\u003e45 \/ 42.5 \/ 33.5 (H\/M\/L)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUnit Dimensions (W×D×H)\u003c\/td\u003e\n\u003ctd\u003e32.68 × 32.68 × 8.07 in\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNet \/ Gross Weight\u003c\/td\u003e\n\u003ctd\u003e47.18 \/ 59.08 lb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRefrigerant Piping\u003c\/td\u003e\n\u003ctd\u003e3\/8\" Liquid • 5\/8\" Gas\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDrain Pipe Diameter\u003c\/td\u003e\n\u003ctd\u003e1\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Range\u003c\/td\u003e\n\u003ctd\u003eCooling: 60–90°F • Heating: 32–86°F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMinimum Circuit Ampacity\u003c\/td\u003e\n\u003ctd\u003e3 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax Fuse\u003c\/td\u003e\n\u003ctd\u003e15 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"hvx-desc-card\"\u003e\n\u003ch3 class=\"hvx-section-title\"\u003eOutdoor Specs (CH-RES24-230VO)\u003c\/h3\u003e\n\u003cdiv class=\"hvx-table-wrap\"\u003e\n\u003ctable class=\"hvx-table\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eSpec\u003c\/th\u003e\n\u003cth\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRefrigerant Type\u003c\/td\u003e\n\u003ctd\u003eR454B\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSystem Type\u003c\/td\u003e\n\u003ctd\u003eSingle-zone unit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBTU Rated\u003c\/td\u003e\n\u003ctd\u003e24,000\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCooling Capacity (Min–Max)\u003c\/td\u003e\n\u003ctd\u003e24,000 (8,500–28,300) BTU\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHeating Capacity (Min–Max)\u003c\/td\u003e\n\u003ctd\u003e25,000 (11,800–35,100) BTU\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSEER2 \/ EER2\u003c\/td\u003e\n\u003ctd\u003e19 \/ 12.5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHSPF2 (Region IV \/ V)\u003c\/td\u003e\n\u003ctd\u003e11 \/ 8.5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCOP\u003c\/td\u003e\n\u003ctd\u003e3.64\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower\u003c\/td\u003e\n\u003ctd\u003e208–230V • 1Ph • 60Hz (Voltage Range: 187–253V)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax Pipe Length\u003c\/td\u003e\n\u003ctd\u003e164 ft\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax Height Difference\u003c\/td\u003e\n\u003ctd\u003e82 ft\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMinimum Circuit Ampacity\u003c\/td\u003e\n\u003ctd\u003e24 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax Fuse\u003c\/td\u003e\n\u003ctd\u003e25 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutdoor Airflow\u003c\/td\u003e\n\u003ctd\u003e2,236.7 CFM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutdoor Noise\u003c\/td\u003e\n\u003ctd\u003e60 dB(A)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUnit Dimensions (W×D×H)\u003c\/td\u003e\n\u003ctd\u003e37.24 × 16.14 × 31.89 in\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNet \/ Gross Weight\u003c\/td\u003e\n\u003ctd\u003e122.13 \/ 132.28 lb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAmbient Temperature\u003c\/td\u003e\n\u003ctd\u003eCooling: -13–122°F • Heating: -13–75°F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAdditional Charge\u003c\/td\u003e\n\u003ctd\u003e0.32 oz\/ft (3\/8\" liquid line)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"hvx-desc-card\"\u003e\n\u003ch3 class=\"hvx-section-title\"\u003eDocuments \u0026amp; Downloads\u003c\/h3\u003e\n\u003cul class=\"hvx-muted\" style=\"margin: 0; padding-left: 18px;\"\u003e\n\u003cli\u003e\u003ca class=\"hvx-link\" href=\"https:\/\/media.cooperandhunter.us\/4680\/CH-RES24-230VO_CH-RH24MCT.pdf\"\u003eSubmittal Sheet: CH-RES24-230VO + CH-RH24MCT\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca class=\"hvx-link\" href=\"https:\/\/media.cooperandhunter.us\/4159\/CH-RES24-230VO-%2B-CH-PRO24MASTWM-230VI.pdf\"\u003eSubmittal Sheet: CH-RES24-230VO + CH-PRO24MASTWM-230VI\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca class=\"hvx-link\" href=\"https:\/\/media.cooperandhunter.us\/4173\/CH-RES24-230VO-%2B-CH-RH24MASTWM-230VI.pdf\"\u003eSubmittal Sheet: CH-RES24-230VO + CH-RH24MASTWM-230VI\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca class=\"hvx-link\" href=\"https:\/\/media.cooperandhunter.us\/4212\/CH-RES24-230VO-%2B-CH-RS24MDT-HS.pdf\"\u003eSubmittal Sheet: CH-RES24-230VO + CH-RS24MDT-HS\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca class=\"hvx-link\" href=\"https:\/\/media.cooperandhunter.us\/4626\/CH-RES24-230VO_CH-RSH24MFC.pdf\"\u003eSubmittal Sheet: CH-RES24-230VO + CH-RSH24MFC\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca class=\"hvx-link\" href=\"https:\/\/media.cooperandhunter.us\/4118\/Installation-Manual-R454B-Outdoor-units--.pdf\"\u003eOutdoor Units Installation Manual (R454B)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca class=\"hvx-link\" href=\"https:\/\/media.cooperandhunter.us\/4200\/SlimDuct-Leaflet-R454B.pdf\"\u003eSlimDuct Leaflet (R454B)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca class=\"hvx-link\" href=\"https:\/\/media.cooperandhunter.us\/4654\/Installation-manual-R454B-Ceiling-cassette_compressed.pdf\"\u003eCeiling Cassette Installation Manual (R454B)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca class=\"hvx-link\" href=\"https:\/\/media.cooperandhunter.us\/4655\/Owners_-manual-R454B-Ceiling-cassette_compressed.pdf\"\u003eCeiling Cassette Owner’s Manual (R454B)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca class=\"hvx-link\" href=\"https:\/\/media.cooperandhunter.us\/3309\/120N--uses-and-installation-manual.pdf\"\u003e120N Wire Controller — Uses \u0026amp; Installation Manual\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca class=\"hvx-link\" href=\"https:\/\/media.cooperandhunter.us\/3198\/MultiZone-Combination-HYPER.pdf\"\u003eMultiZone Combination Guide — Hyper\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca class=\"hvx-link\" href=\"https:\/\/media.cooperandhunter.us\/3199\/MultiZone-Combination-Regular.pdf\"\u003eMultiZone Combination Guide — Regular\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"hvx-desc-card\"\u003e\n\u003ch3 class=\"hvx-section-title\"\u003eImportant\u003c\/h3\u003e\n\u003cul class=\"hvx-muted\" style=\"margin: 0; padding-left: 18px;\"\u003e\n\u003cli\u003eProfessional installation is recommended.\u003c\/li\u003e\n\u003cli\u003eMatch line set sizes to the equipment: 3\/8\" liquid and 5\/8\" suction.\u003c\/li\u003e\n\u003cli\u003eVerify the dedicated circuit is sized per equipment MCA and local code.\u003c\/li\u003e\n\u003cli\u003eFor help choosing equipment, contact us: \u003ca class=\"hvx-link\" href=\"https:\/\/hvacsupplies.com\/pages\/contact\"\u003ehvacsupplies.com\/pages\/contact\u003c\/a\u003e • \u003ca class=\"hvx-link\" href=\"tel:+18005438933\"\u003e(800) 543-8933\u003c\/a\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"hvx-desc-card hvx-faq\"\u003e\n\u003ch3 class=\"hvx-section-title\"\u003eFAQs\u003c\/h3\u003e\n\u003cdetails\u003e\n\u003csummary\u003eDoes the indoor cassette include a condensate pump?\u003c\/summary\u003e\n\u003cp class=\"hvx-muted\"\u003eYes. CH-RH24MCT includes a built-in pump with float switch (20.9\" lift).\u003c\/p\u003e\n\u003c\/details\u003e\n\u003cdetails\u003e\n\u003csummary\u003eWhat line set sizes are required for this 24K cassette?\u003c\/summary\u003e\n\u003cp class=\"hvx-muted\"\u003e3\/8\" liquid line and 5\/8\" suction (gas) line.\u003c\/p\u003e\n\u003c\/details\u003e\n\u003cdetails\u003e\n\u003csummary\u003eHow cold can the regular outdoor unit operate in heating?\u003c\/summary\u003e\n\u003cp class=\"hvx-muted\"\u003eCH-RES24-230VO supports heating operation down to -13°F ambient.\u003c\/p\u003e\n\u003c\/details\u003e\n\u003cdetails\u003e\n\u003csummary\u003eCan I control the system with an app?\u003c\/summary\u003e\n\u003cp class=\"hvx-muted\"\u003eSmart Kit capability supports app control through the C\u0026amp;H platform after setup.\u003c\/p\u003e\n\u003c\/details\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e","brand":"Cooper\u0026Hunter","offers":[{"title":"No Installation","offer_id":42691022094379,"sku":"CH-RH24MCT + CH-RES24-230VO","price":2261.0,"currency_code":"USD","in_stock":true},{"title":"16FT","offer_id":42691022127147,"sku":"CH-RH24MCT + CH-RES24-230VO","price":2477.0,"currency_code":"USD","in_stock":true},{"title":"25FT","offer_id":42691022159915,"sku":"CH-RH24MCT + CH-RES24-230VO","price":2606.0,"currency_code":"USD","in_stock":true},{"title":"50FT","offer_id":42691022192683,"sku":"CH-RH24MCT + CH-RES24-230VO","price":2913.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0625\/5647\/1339\/files\/FourWay_Regular_Product_Hero_48_33b3a9f5-7a1c-442f-a881-e51e604eb6c3.png?v=1769199174"},{"product_id":"cooper-hunter-36-000-btu-hyper-pro-single-zone-four-way-ceiling-cassette-w-refrigerant-humidity-sensor-minisplit-heat-pump-system-r454b-230v","title":"Cooper\u0026Hunter 36,000 BTU Hyper Pro Single Zone Four-Way Ceiling Cassette w\/ Refrigerant \u0026 Humidity Sensor Minisplit Heat Pump System R454B 230V","description":"\u003cstyle\u003e\n    :root{--hvx-golden:#FAA819;--hvx-slate:#262626;--hvx-ivory:#F4F1E6;--hvx-border:#e2e0d5;--hvx-card-bg:#ffffff;}\n    .hvx-desc{background:var(--hvx-ivory);padding:18px;border-radius:18px;font-family:\"Articulat CF\",system-ui,-apple-system,Segoe UI,Roboto,Arial,sans-serif;color:#111;}\n    .hvx-desc-header{background:linear-gradient(120deg,var(--hvx-golden),var(--hvx-slate));border-radius:16px;padding:16px 16px 14px;color:#fff;margin-bottom:14px;}\n    .hvx-eyebrow{font-size:12px;letter-spacing:.12em;text-transform:uppercase;opacity:.9;margin:0 0 6px;}\n    .hvx-title{font-family:\"Anton\",Impact,Haettenschweiler,\"Arial Narrow Bold\",sans-serif;font-size:26px;line-height:1.05;margin:0;}\n    .hvx-desc-card{background:var(--hvx-card-bg);border:1px solid var(--hvx-border);border-radius:16px;padding:14px;margin:12px 0;box-shadow:0 10px 18px rgba(0,0,0,.06);}\n    .hvx-section-title{margin:0 0 10px;font-size:13px;letter-spacing:.12em;text-transform:uppercase;display:inline-block;padding-bottom:6px;position:relative;}\n    .hvx-section-title:after{content:\"\";position:absolute;left:0;bottom:0;height:3px;width:100%;border-radius:99px;background:linear-gradient(90deg,var(--hvx-golden),var(--hvx-slate));}\n    .hvx-badges{display:flex;flex-wrap:wrap;gap:8px;margin:6px 0 10px;}\n    .hvx-badge{display:inline-flex;align-items:center;gap:6px;padding:6px 10px;border-radius:999px;border:1px solid var(--hvx-border);background:#fff;font-size:12px;font-weight:600;}\n    .hvx-grid{display:grid;grid-template-columns:repeat(3,minmax(0,1fr));gap:10px;}\n    .hvx-kv{border:1px solid var(--hvx-border);border-radius:14px;padding:10px;background:#fff;}\n    .hvx-k{font-size:12px;letter-spacing:.08em;text-transform:uppercase;color:#333;margin:0 0 6px;}\n    .hvx-v{font-size:14px;font-weight:700;margin:0;}\n    .hvx-table-wrap{overflow:auto;border-radius:14px;border:1px solid var(--hvx-border);background:#fff;}\n    table.hvx-table{width:100%;border-collapse:collapse;min-width:520px;}\n    .hvx-table th,.hvx-table td{padding:10px 12px;border-bottom:1px solid var(--hvx-border);vertical-align:top;font-size:14px;}\n    .hvx-table th{background:rgba(250,168,25,.12);text-align:left;font-size:12px;letter-spacing:.1em;text-transform:uppercase;}\n    .hvx-table tr:last-child td{border-bottom:none;}\n    .hvx-link{color:#111;text-decoration:none;border-bottom:2px solid rgba(250,168,25,.7);}\n    .hvx-link:hover{border-bottom-color:#111;}\n    .hvx-faq details{border:1px solid var(--hvx-border);border-radius:14px;background:#fff;padding:10px 12px;margin:10px 0;}\n    .hvx-faq summary{cursor:pointer;font-weight:800;}\n    .hvx-muted{color:#333;margin:6px 0 0;}\n    @media (max-width:720px){.hvx-grid{grid-template-columns:1fr;}.hvx-title{font-size:24px;}}\n  \u003c\/style\u003e\n\u003cdiv class=\"hvx-desc\"\u003e\n\u003cdiv class=\"hvx-desc-header\"\u003e\n\u003cp class=\"hvx-eyebrow\"\u003eSingle Zone • 4-Way Ceiling Cassette • R454B • 208–230V\u003c\/p\u003e\n\u003ch2 class=\"hvx-title\"\u003eCooper\u0026amp;Hunter 24,000 BTU Hyper Pro Single Zone Four-Way Ceiling Cassette w\/ Refrigerant \u0026amp; Humidity Sensor Minisplit Heat Pump System R454B 230V\u003c\/h2\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"hvx-desc-card\"\u003e\n\u003ch3 class=\"hvx-section-title\"\u003eOverview\u003c\/h3\u003e\n\u003cp class=\"hvx-muted\"\u003eA 24K four-way ceiling cassette pairing designed for wide, even airflow with added system protection. The CH-RSH24MCT cassette includes refrigerant leakage detection plus humidity sensing and self-diagnosis features, and includes a built-in condensate pump. Pair it with the CH-RHP24-230VO Hyper outdoor unit for low-ambient heating down to -22°F.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"hvx-desc-card\"\u003e\n\u003ch3 class=\"hvx-section-title\"\u003eHighlights\u003c\/h3\u003e\n\u003cdiv class=\"hvx-badges\"\u003e\n\u003cspan class=\"hvx-badge\"\u003eR454B Refrigerant\u003c\/span\u003e \u003cspan class=\"hvx-badge\"\u003e360° Airflow Panel\u003c\/span\u003e \u003cspan class=\"hvx-badge\"\u003eLeak Detection (RSH)\u003c\/span\u003e \u003cspan class=\"hvx-badge\"\u003eHumidity Sensor\u003c\/span\u003e \u003cspan class=\"hvx-badge\"\u003eGoldFin Coil Coating\u003c\/span\u003e \u003cspan class=\"hvx-badge\"\u003eBuilt-In Condensate Pump\u003c\/span\u003e \u003cspan class=\"hvx-badge\"\u003eHyper Heating Outdoor\u003c\/span\u003e\n\u003c\/div\u003e\n\u003cul style=\"margin: 0 0 10px; padding-left: 18px;\" class=\"hvx-muted\"\u003e\n\u003cli\u003eOmni-directional airflow and 360° panel helps distribute air evenly throughout the room.\u003c\/li\u003e\n\u003cli\u003eActivated carbon filtration support for fresher indoor air.\u003c\/li\u003e\n\u003cli\u003eRefrigerant leakage detection helps protect the system in abnormal conditions.\u003c\/li\u003e\n\u003cli\u003eAnti-cold-air heating behavior reduces drafts during heat mode.\u003c\/li\u003e\n\u003cli\u003eBuilt-in pump with float switch (20.9\" lift) for quiet condensate removal.\u003c\/li\u003e\n\u003cli\u003eHyper outdoor unit supports heating operation down to -22°F ambient.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cdiv class=\"hvx-grid\"\u003e\n\u003cdiv class=\"hvx-kv\"\u003e\n\u003cp class=\"hvx-k\"\u003eIndoor Model\u003c\/p\u003e\n\u003cp class=\"hvx-v\"\u003e\u003ca href=\"https:\/\/hvacsupplies.com\/search?options%5Bprefix%5D=last\u0026amp;q=CH-RSH24MCT\" class=\"hvx-link\"\u003eCH-RSH24MCT\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"hvx-kv\"\u003e\n\u003cp class=\"hvx-k\"\u003eOutdoor Model\u003c\/p\u003e\n\u003cp class=\"hvx-v\"\u003e\u003ca href=\"https:\/\/hvacsupplies.com\/search?options%5Bprefix%5D=last\u0026amp;q=CH-RHP24-230VO\" class=\"hvx-link\"\u003eCH-RHP24-230VO\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"hvx-kv\"\u003e\n\u003cp class=\"hvx-k\"\u003eLine Set Size\u003c\/p\u003e\n\u003cp class=\"hvx-v\"\u003e3\/8\" Liquid • 5\/8\" Gas\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"hvx-kv\"\u003e\n\u003cp class=\"hvx-k\"\u003ePower\u003c\/p\u003e\n\u003cp class=\"hvx-v\"\u003e208–230V • 1Ph • 60Hz\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"hvx-kv\"\u003e\n\u003cp class=\"hvx-k\"\u003eMax Line Length\u003c\/p\u003e\n\u003cp class=\"hvx-v\"\u003e164 ft\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"hvx-kv\"\u003e\n\u003cp class=\"hvx-k\"\u003eLow-Ambient Heating\u003c\/p\u003e\n\u003cp class=\"hvx-v\"\u003eDown to -22°F\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"hvx-desc-card\"\u003e\n\u003ch3 class=\"hvx-section-title\"\u003eWhat’s Included\u003c\/h3\u003e\n\u003cul style=\"margin: 0; padding-left: 18px;\" class=\"hvx-muted\"\u003e\n\u003cli\u003eIndoor 4-way ceiling cassette: CH-RSH24MCT\u003c\/li\u003e\n\u003cli\u003eOutdoor condenser: CH-RHP24-230VO (Hyper)\u003c\/li\u003e\n\u003cli\u003eRemote control (indoor control package)\u003c\/li\u003e\n\u003cli\u003eCeiling Cassette Panel\u003c\/li\u003e\n\u003cli\u003eBuilt-in condensate pump with float switch (indoor)\u003c\/li\u003e\n\u003cli\u003eSmart Kit capability for app control (setup required)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"hvx-desc-card\"\u003e\n\u003ch3 class=\"hvx-section-title\"\u003eIndoor Specs (CH-RSH24MCT)\u003c\/h3\u003e\n\u003cdiv class=\"hvx-table-wrap\"\u003e\n\u003ctable class=\"hvx-table\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eSpec\u003c\/th\u003e\n\u003cth\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRefrigerant Type\u003c\/td\u003e\n\u003ctd\u003eR454B\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSystem Type\u003c\/td\u003e\n\u003ctd\u003eSingle Zone\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBTU Rated\u003c\/td\u003e\n\u003ctd\u003e24,000\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower\u003c\/td\u003e\n\u003ctd\u003e208–230V • 1Ph • 60Hz (Voltage Range: 187–253V)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSEER2 \/ EER2\u003c\/td\u003e\n\u003ctd\u003e20.7 \/ 12\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDehumidification\u003c\/td\u003e\n\u003ctd\u003e4.99 pints\/day\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIndoor Airflow (CFM)\u003c\/td\u003e\n\u003ctd\u003e765.2 \/ 706.3 \/ 635.7 \/ 547.4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNoise (dB(A))\u003c\/td\u003e\n\u003ctd\u003e45 \/ 42.5 \/ 33.5 (H\/M\/L)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUnit Dimensions (W×D×H)\u003c\/td\u003e\n\u003ctd\u003e32.68 × 32.68 × 8.07 in\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNet \/ Gross Weight\u003c\/td\u003e\n\u003ctd\u003e47.18 \/ 59.08 lb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRefrigerant Piping\u003c\/td\u003e\n\u003ctd\u003e3\/8\" Liquid • 5\/8\" Gas\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDrain Pipe Diameter\u003c\/td\u003e\n\u003ctd\u003e1\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Range\u003c\/td\u003e\n\u003ctd\u003eCooling: 60–90°F • Heating: 32–86°F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMinimum Circuit Ampacity\u003c\/td\u003e\n\u003ctd\u003e3 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax Fuse\u003c\/td\u003e\n\u003ctd\u003e15 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"hvx-desc-card\"\u003e\n\u003ch3 class=\"hvx-section-title\"\u003eOutdoor Specs (CH-RHP24-230VO)\u003c\/h3\u003e\n\u003cdiv class=\"hvx-table-wrap\"\u003e\n\u003ctable class=\"hvx-table\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eSpec\u003c\/th\u003e\n\u003cth\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRefrigerant Type\u003c\/td\u003e\n\u003ctd\u003eR454B\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBTU Rated\u003c\/td\u003e\n\u003ctd\u003e24,000\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCooling Capacity (Min–Max)\u003c\/td\u003e\n\u003ctd\u003e24,000 (12,600–27,900) BTU\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHeating Capacity (Min–Max)\u003c\/td\u003e\n\u003ctd\u003e29,000 (11,800–29,700) BTU\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHSPF2 (Region IV \/ V)\u003c\/td\u003e\n\u003ctd\u003e13.5 \/ 9.8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCOP\u003c\/td\u003e\n\u003ctd\u003e3.42\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower\u003c\/td\u003e\n\u003ctd\u003e208–230V • 1Ph • 60Hz (Voltage Range: 187–253V)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax Pipe Length\u003c\/td\u003e\n\u003ctd\u003e164 ft\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax Height Difference\u003c\/td\u003e\n\u003ctd\u003e82 ft\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMinimum Circuit Ampacity\u003c\/td\u003e\n\u003ctd\u003e24.9 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax Fuse\u003c\/td\u003e\n\u003ctd\u003e25 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutdoor Airflow\u003c\/td\u003e\n\u003ctd\u003e2,235.3 CFM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutdoor Noise\u003c\/td\u003e\n\u003ctd\u003e61.5 dB(A)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUnit Dimensions (W×D×H)\u003c\/td\u003e\n\u003ctd\u003e37.24 × 16.14 × 31.89 in\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNet \/ Gross Weight\u003c\/td\u003e\n\u003ctd\u003e130.29 \/ 141.31 lb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAmbient Temperature\u003c\/td\u003e\n\u003ctd\u003eCooling: -22–122°F • Heating: -22–75°F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAdditional Charge\u003c\/td\u003e\n\u003ctd\u003e0.32 oz\/ft (3\/8\" liquid line)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"hvx-desc-card\"\u003e\n\u003ch3 class=\"hvx-section-title\"\u003eDocuments \u0026amp; Downloads\u003c\/h3\u003e\n\u003cul style=\"margin: 0; padding-left: 18px;\" class=\"hvx-muted\"\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/media.cooperandhunter.us\/4688\/CH-RHP24-230VO_CH-RH24MCT.pdf\" class=\"hvx-link\"\u003eSubmittal Sheet: CH-RHP24-230VO + CH-RH24MCT\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/media.cooperandhunter.us\/4681\/CH-RES24-230VO_CH-RSH24MCT.pdf\" class=\"hvx-link\"\u003eSubmittal Sheet: CH-RES24-230VO + CH-RSH24MCT\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/media.cooperandhunter.us\/4118\/Installation-Manual-R454B-Outdoor-units--.pdf\" class=\"hvx-link\"\u003eOutdoor Units Installation Manual (R454B)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/media.cooperandhunter.us\/4200\/SlimDuct-Leaflet-R454B.pdf\" class=\"hvx-link\"\u003eSlimDuct Leaflet (R454B)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/media.cooperandhunter.us\/4654\/Installation-manual-R454B-Ceiling-cassette_compressed.pdf\" class=\"hvx-link\"\u003eCeiling Cassette Installation Manual (R454B)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/media.cooperandhunter.us\/4655\/Owners_-manual-R454B-Ceiling-cassette_compressed.pdf\" class=\"hvx-link\"\u003eCeiling Cassette Owner’s Manual (R454B)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/media.cooperandhunter.us\/3309\/120N--uses-and-installation-manual.pdf\" class=\"hvx-link\"\u003e120N Wire Controller — Uses \u0026amp; Installation Manual\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/media.cooperandhunter.us\/3198\/MultiZone-Combination-HYPER.pdf\" class=\"hvx-link\"\u003eMultiZone Combination Guide — Hyper\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/media.cooperandhunter.us\/3199\/MultiZone-Combination-Regular.pdf\" class=\"hvx-link\"\u003eMultiZone Combination Guide — Regular\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/media.cooperandhunter.us\/3959\/CH-RHP24-230VO-%2B-CH-RS24MAHU.pdf\" class=\"hvx-link\"\u003eSubmittal Sheet: CH-RHP24-230VO + CH-RS24MAHU\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/media.cooperandhunter.us\/4160\/CH-RHP24-230VO-%2B-CH-PRO24MASTWM-230VI.pdf\" class=\"hvx-link\"\u003eSubmittal Sheet: CH-RHP24-230VO + CH-PRO24MASTWM-230VI\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/media.cooperandhunter.us\/4174\/CH-RHP24-230VO-%2B-CH-RH24MASTWM-230VI.pdf\" class=\"hvx-link\"\u003eSubmittal Sheet: CH-RHP24-230VO + CH-RH24MASTWM-230VI\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/media.cooperandhunter.us\/4205\/CH-RHP24-230VO-%2B-CH-RS24MDT-HS.pdf\" class=\"hvx-link\"\u003eSubmittal Sheet: CH-RHP24-230VO + CH-RS24MDT-HS\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/media.cooperandhunter.us\/4631\/CH-RHP24-230VO_CH-RSH24MFC.pdf\" class=\"hvx-link\"\u003eSubmittal Sheet: CH-RHP24-230VO + CH-RSH24MFC\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"hvx-desc-card\"\u003e\n\u003ch3 class=\"hvx-section-title\"\u003eImportant\u003c\/h3\u003e\n\u003cul style=\"margin: 0; padding-left: 18px;\" class=\"hvx-muted\"\u003e\n\u003cli\u003eProfessional installation is recommended.\u003c\/li\u003e\n\u003cli\u003eMatch line set sizes to the equipment: 3\/8\" liquid and 5\/8\" suction.\u003c\/li\u003e\n\u003cli\u003eVerify the dedicated circuit is sized per equipment MCA and local code.\u003c\/li\u003e\n\u003cli\u003eFor help choosing equipment, contact us: \u003ca href=\"https:\/\/hvacsupplies.com\/pages\/contact\" class=\"hvx-link\"\u003ehvacsupplies.com\/pages\/contact\u003c\/a\u003e • \u003ca href=\"tel:+18005438933\" class=\"hvx-link\"\u003e(800) 543-8933\u003c\/a\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"hvx-desc-card hvx-faq\"\u003e\n\u003ch3 class=\"hvx-section-title\"\u003eFAQs\u003c\/h3\u003e\n\u003cdetails\u003e\n\u003csummary\u003eWhat is the difference between RH and RSH cassettes?\u003c\/summary\u003e\n\u003cp class=\"hvx-muted\"\u003eRSH models add refrigerant leakage detection in addition to standard monitoring features.\u003c\/p\u003e\n\u003c\/details\u003e\n\u003cdetails\u003e\n\u003csummary\u003eWhat line set sizes are required for this 24K cassette?\u003c\/summary\u003e\n\u003cp class=\"hvx-muted\"\u003e3\/8\" liquid line and 5\/8\" suction (gas) line.\u003c\/p\u003e\n\u003c\/details\u003e\n\u003cdetails\u003e\n\u003csummary\u003eHow cold can the Hyper outdoor unit heat?\u003c\/summary\u003e\n\u003cp class=\"hvx-muted\"\u003eCH-RHP24-230VO supports heating operation down to -22°F ambient.\u003c\/p\u003e\n\u003c\/details\u003e\n\u003cdetails\u003e\n\u003csummary\u003eDoes the indoor cassette include a condensate pump?\u003c\/summary\u003e\n\u003cp class=\"hvx-muted\"\u003eYes. CH-RSH24MCT includes a built-in pump with float switch (20.9\" lift).\u003c\/p\u003e\n\u003c\/details\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e","brand":"Cooper\u0026Hunter","offers":[{"title":"No Installation","offer_id":42691112271915,"sku":"CH-RSH36LCCT + CH-RHP36LCU-230VO","price":4914.0,"currency_code":"USD","in_stock":true},{"title":"25FT","offer_id":42691112337451,"sku":"CH-RSH36LCCT + CH-RHP36LCU-230VO","price":5395.0,"currency_code":"USD","in_stock":true},{"title":"50FT","offer_id":42691112370219,"sku":"CH-RSH36LCCT + CH-RHP36LCU-230VO","price":5588.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0625\/5647\/1339\/files\/2-ZoneDuctlessMiniSplitAC_HeatPump48000BTU_26.png?v=1769199192"},{"product_id":"cooper-hunter-36-000-btu-pro-single-zone-four-way-ceiling-cassette-w-refrigerant-humidity-sensor-minisplit-heat-pump-system-r454b-230v","title":"Cooper\u0026Hunter 36,000 BTU Pro Single Zone Four-Way Ceiling Cassette w\/ Refrigerant \u0026 Humidity Sensor Minisplit Heat Pump System R454B 230V","description":"\u003cstyle\u003e\n    :root{--hvx-golden:#FAA819;--hvx-slate:#262626;--hvx-ivory:#F4F1E6;--hvx-border:#e2e0d5;--hvx-card-bg:#ffffff;}\n    .hvx-desc{background:var(--hvx-ivory);padding:18px;border-radius:18px;font-family:\"Articulat CF\",system-ui,-apple-system,Segoe UI,Roboto,Arial,sans-serif;color:#111;}\n    .hvx-desc-header{background:linear-gradient(120deg,var(--hvx-golden),var(--hvx-slate));border-radius:16px;padding:16px 16px 14px;color:#fff;margin-bottom:14px;}\n    .hvx-eyebrow{font-size:12px;letter-spacing:.12em;text-transform:uppercase;opacity:.9;margin:0 0 6px;}\n    .hvx-title{font-family:\"Anton\",Impact,Haettenschweiler,\"Arial Narrow Bold\",sans-serif;font-size:26px;line-height:1.05;margin:0;}\n    .hvx-desc-card{background:var(--hvx-card-bg);border:1px solid var(--hvx-border);border-radius:16px;padding:14px;margin:12px 0;box-shadow:0 10px 18px rgba(0,0,0,.06);}\n    .hvx-section-title{margin:0 0 10px;font-size:13px;letter-spacing:.12em;text-transform:uppercase;display:inline-block;padding-bottom:6px;position:relative;}\n    .hvx-section-title:after{content:\"\";position:absolute;left:0;bottom:0;height:3px;width:100%;border-radius:99px;background:linear-gradient(90deg,var(--hvx-golden),var(--hvx-slate));}\n    .hvx-badges{display:flex;flex-wrap:wrap;gap:8px;margin:6px 0 10px;}\n    .hvx-badge{display:inline-flex;align-items:center;gap:6px;padding:6px 10px;border-radius:999px;border:1px solid var(--hvx-border);background:#fff;font-size:12px;font-weight:600;}\n    .hvx-grid{display:grid;grid-template-columns:repeat(3,minmax(0,1fr));gap:10px;}\n    .hvx-kv{border:1px solid var(--hvx-border);border-radius:14px;padding:10px;background:#fff;}\n    .hvx-k{font-size:12px;letter-spacing:.08em;text-transform:uppercase;color:#333;margin:0 0 6px;}\n    .hvx-v{font-size:14px;font-weight:700;margin:0;}\n    .hvx-table-wrap{overflow:auto;border-radius:14px;border:1px solid var(--hvx-border);background:#fff;}\n    table.hvx-table{width:100%;border-collapse:collapse;min-width:520px;}\n    .hvx-table th,.hvx-table td{padding:10px 12px;border-bottom:1px solid var(--hvx-border);vertical-align:top;font-size:14px;}\n    .hvx-table th{background:rgba(250,168,25,.12);text-align:left;font-size:12px;letter-spacing:.1em;text-transform:uppercase;}\n    .hvx-table tr:last-child td{border-bottom:none;}\n    .hvx-link{color:#111;text-decoration:none;border-bottom:2px solid rgba(250,168,25,.7);}\n    .hvx-link:hover{border-bottom-color:#111;}\n    .hvx-faq details{border:1px solid var(--hvx-border);border-radius:14px;background:#fff;padding:10px 12px;margin:10px 0;}\n    .hvx-faq summary{cursor:pointer;font-weight:800;}\n    .hvx-muted{color:#333;margin:6px 0 0;}\n    @media (max-width:720px){.hvx-grid{grid-template-columns:1fr;}.hvx-title{font-size:24px;}}\n  \u003c\/style\u003e\n\u003cdiv class=\"hvx-desc\"\u003e\n\u003cdiv class=\"hvx-desc-header\"\u003e\n\u003cp class=\"hvx-eyebrow\"\u003eSingle Zone • 36,000 BTU • Ceiling Cassette PRO • R454B • 208–230V\u003c\/p\u003e\n\u003ch2 class=\"hvx-title\"\u003eCooper\u0026amp;Hunter 36,000 BTU Pro Single Zone Four-Way Ceiling Cassette w\/ Refrigerant \u0026amp; Humidity Sensor Minisplit Heat Pump System R454B 230V\u003c\/h2\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"hvx-desc-card\"\u003e\n\u003ch3 class=\"hvx-section-title\"\u003eOverview\u003c\/h3\u003e\n\u003cp class=\"hvx-muted\"\u003eA 36K ceiling cassette system built for large residential and light commercial applications. The CH-RSH36LCCT delivers wide coverage with a 360° airflow panel and includes a built-in condensate pump. Safety monitoring includes refrigerant leak detection plus self-diagnosis. Pair with the CH-R36LCU-230VO for efficient inverter performance.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"hvx-desc-card\"\u003e\n\u003ch3 class=\"hvx-section-title\"\u003eHighlights\u003c\/h3\u003e\n\u003cdiv class=\"hvx-badges\"\u003e\n\u003cspan class=\"hvx-badge\"\u003eR454B Refrigerant\u003c\/span\u003e \u003cspan class=\"hvx-badge\"\u003e360° Airflow Panel\u003c\/span\u003e \u003cspan class=\"hvx-badge\"\u003eLeak Detection (RSH)\u003c\/span\u003e \u003cspan class=\"hvx-badge\"\u003eHumidity Sensor\u003c\/span\u003e \u003cspan class=\"hvx-badge\"\u003eGoldFin Coating\u003c\/span\u003e \u003cspan class=\"hvx-badge\"\u003eBuilt-In Pump\u003c\/span\u003e \u003cspan class=\"hvx-badge\"\u003eInverter Outdoor\u003c\/span\u003e\n\u003c\/div\u003e\n\u003cul style=\"margin: 0 0 10px; padding-left: 18px;\" class=\"hvx-muted\"\u003e\n\u003cli\u003e360° panel and omni-directional airflow helps cover large rooms evenly.\u003c\/li\u003e\n\u003cli\u003eActivated carbon filtration support for fresher indoor air.\u003c\/li\u003e\n\u003cli\u003eAnti-cold-air heating behavior reduces drafts during heat mode.\u003c\/li\u003e\n\u003cli\u003eRefrigerant leakage detection and self-diagnosis features for added protection.\u003c\/li\u003e\n\u003cli\u003eBuilt-in pump with float switch (20.9\" lift) for quiet condensate removal.\u003c\/li\u003e\n\u003cli\u003eOutdoor heating operation supports down to -13°F ambient.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cdiv class=\"hvx-grid\"\u003e\n\u003cdiv class=\"hvx-kv\"\u003e\n\u003cp class=\"hvx-k\"\u003eIndoor Model\u003c\/p\u003e\n\u003cp class=\"hvx-v\"\u003e\u003ca href=\"https:\/\/hvacsupplies.com\/search?options%5Bprefix%5D=last\u0026amp;q=CH-RSH36LCCT\" class=\"hvx-link\"\u003eCH-RSH36LCCT\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"hvx-kv\"\u003e\n\u003cp class=\"hvx-k\"\u003eOutdoor Model\u003c\/p\u003e\n\u003cp class=\"hvx-v\"\u003e\u003ca href=\"https:\/\/hvacsupplies.com\/search?options%5Bprefix%5D=last\u0026amp;q=CH-R36LCU-230VO\" class=\"hvx-link\"\u003eCH-R36LCU-230VO\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"hvx-kv\"\u003e\n\u003cp class=\"hvx-k\"\u003eLine Set Size\u003c\/p\u003e\n\u003cp class=\"hvx-v\"\u003e3\/8\" Liquid • 3\/4\" Gas\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"hvx-kv\"\u003e\n\u003cp class=\"hvx-k\"\u003ePower\u003c\/p\u003e\n\u003cp class=\"hvx-v\"\u003e208–230V • 1Ph • 60Hz\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"hvx-kv\"\u003e\n\u003cp class=\"hvx-k\"\u003eMax Line Length\u003c\/p\u003e\n\u003cp class=\"hvx-v\"\u003e246 ft\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"hvx-kv\"\u003e\n\u003cp class=\"hvx-k\"\u003eLow-Ambient Heating\u003c\/p\u003e\n\u003cp class=\"hvx-v\"\u003eDown to -13°F\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"hvx-desc-card\"\u003e\n\u003ch3 class=\"hvx-section-title\"\u003eWhat’s Included\u003c\/h3\u003e\n\u003cul style=\"margin: 0; padding-left: 18px;\" class=\"hvx-muted\"\u003e\n\u003cli\u003eIndoor 4-way ceiling cassette: CH-RSH36LCCT\u003c\/li\u003e\n\u003cli\u003eOutdoor condenser: CH-R36LCU-230VO\u003c\/li\u003e\n\u003cli\u003eRemote control (indoor control package)\u003c\/li\u003e\n\u003cli\u003eCeiling Cassette Panel\u003c\/li\u003e\n\u003cli\u003eBuilt-in condensate pump with float switch (indoor)\u003c\/li\u003e\n\u003cli\u003eSmart Kit capability for app control (setup required)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"hvx-desc-card\"\u003e\n\u003ch3 class=\"hvx-section-title\"\u003eIndoor Specs (CH-RSH36LCCT)\u003c\/h3\u003e\n\u003cdiv class=\"hvx-table-wrap\"\u003e\n\u003ctable class=\"hvx-table\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eSpec\u003c\/th\u003e\n\u003cth\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRefrigerant Type\u003c\/td\u003e\n\u003ctd\u003eR454B\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSystem Type\u003c\/td\u003e\n\u003ctd\u003eSingle Zone\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBTU Rated\u003c\/td\u003e\n\u003ctd\u003e36,000\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower\u003c\/td\u003e\n\u003ctd\u003e208–230V • 1Ph • 60Hz (Voltage Range: 187–253V)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSEER2 \/ EER2\u003c\/td\u003e\n\u003ctd\u003e21.2 \/ 12\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDehumidification\u003c\/td\u003e\n\u003ctd\u003e9.09 pints\/day\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIndoor Airflow (CFM)\u003c\/td\u003e\n\u003ctd\u003e1,041.8 \/ 947.6 \/ 853.5 \/ 753.4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNoise (dB(A))\u003c\/td\u003e\n\u003ctd\u003e52 \/ 47.5 \/ 40 (H\/M\/L)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUnit Dimensions (W×D×H)\u003c\/td\u003e\n\u003ctd\u003e32.68 × 32.68 × 9.65 in\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNet \/ Gross Weight\u003c\/td\u003e\n\u003ctd\u003e59.30 \/ 71.43 lb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRefrigerant Piping\u003c\/td\u003e\n\u003ctd\u003e3\/8\" Liquid • 3\/4\" Gas\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDrain Pipe Diameter\u003c\/td\u003e\n\u003ctd\u003e1\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Range\u003c\/td\u003e\n\u003ctd\u003eCooling: 60–90°F • Heating: 32–86°F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMinimum Circuit Ampacity\u003c\/td\u003e\n\u003ctd\u003e3 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax Fuse\u003c\/td\u003e\n\u003ctd\u003e15 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"hvx-desc-card\"\u003e\n\u003ch3 class=\"hvx-section-title\"\u003eOutdoor Specs (CH-R36LCU-230VO)\u003c\/h3\u003e\n\u003cdiv class=\"hvx-table-wrap\"\u003e\n\u003ctable class=\"hvx-table\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eSpec\u003c\/th\u003e\n\u003cth\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRefrigerant Type\u003c\/td\u003e\n\u003ctd\u003eR454B\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSystem Type\u003c\/td\u003e\n\u003ctd\u003eSingle-zone unit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBTU Rated\u003c\/td\u003e\n\u003ctd\u003e36,000\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCooling Capacity (Min–Max)\u003c\/td\u003e\n\u003ctd\u003e36,000 (7,900–42,500) BTU\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHeating Capacity (Min–Max)\u003c\/td\u003e\n\u003ctd\u003e40,000 (8,100–43,500) BTU\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSEER2 \/ EER2\u003c\/td\u003e\n\u003ctd\u003e18.7 \/ 10.1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHSPF2 (Region IV \/ V)\u003c\/td\u003e\n\u003ctd\u003e10.2 \/ 7.8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCOP\u003c\/td\u003e\n\u003ctd\u003e3.7\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAHRI\u003c\/td\u003e\n\u003ctd\u003e207742340\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower\u003c\/td\u003e\n\u003ctd\u003e208–230V • 1Ph • 60Hz (Voltage Range: 187–253V)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax Pipe Length\u003c\/td\u003e\n\u003ctd\u003e246 ft\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax Height Difference\u003c\/td\u003e\n\u003ctd\u003e98.4 ft\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMinimum Circuit Ampacity\u003c\/td\u003e\n\u003ctd\u003e33 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax Fuse\u003c\/td\u003e\n\u003ctd\u003e35 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutdoor Airflow\u003c\/td\u003e\n\u003ctd\u003e2,413.3 CFM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutdoor Noise\u003c\/td\u003e\n\u003ctd\u003e63 dB(A)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUnit Dimensions (W×D×H)\u003c\/td\u003e\n\u003ctd\u003e37.24 × 16.14 × 31.89 in\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNet \/ Gross Weight\u003c\/td\u003e\n\u003ctd\u003e152.34 \/ 162.48 lb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAmbient Temperature\u003c\/td\u003e\n\u003ctd\u003eCooling: -13–122°F • Heating: -13–75°F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAdditional Charge\u003c\/td\u003e\n\u003ctd\u003e0.32 oz\/ft (3\/8\" liquid line)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"hvx-desc-card\"\u003e\n\u003ch3 class=\"hvx-section-title\"\u003eDocuments \u0026amp; Downloads\u003c\/h3\u003e\n\u003cul style=\"margin: 0; padding-left: 18px;\" class=\"hvx-muted\"\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/media.cooperandhunter.us\/4690\/CH-R36LCU-230VO_CH-RSH36LCCT.pdf\" class=\"hvx-link\"\u003eSubmittal Sheet: CH-R36LCU-230VO + CH-RSH36LCCT\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/media.cooperandhunter.us\/4213\/CH-R36LCU-230VO-%2B-CH-RS36LCDT-HS.pdf\" class=\"hvx-link\"\u003eSubmittal Sheet: CH-R36LCU-230VO + CH-RS36LCDT-HS\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/media.cooperandhunter.us\/4627\/CH-R36LCU-230VO_CH-RSH36LCFC.pdf\" class=\"hvx-link\"\u003eSubmittal Sheet: CH-R36LCU-230VO + CH-RSH36LCFC\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/media.cooperandhunter.us\/4689\/CH-R36LCU-230VO_CH-RH36LCCT.pdf\" class=\"hvx-link\"\u003eSubmittal Sheet: CH-R36LCU-230VO + CH-RH36LCCT\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/media.cooperandhunter.us\/4200\/SlimDuct-Leaflet-R454B.pdf\" class=\"hvx-link\"\u003eSlimDuct Leaflet (R454B)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/media.cooperandhunter.us\/4654\/Installation-manual-R454B-Ceiling-cassette_compressed.pdf\" class=\"hvx-link\"\u003eCeiling Cassette Installation Manual (R454B)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/media.cooperandhunter.us\/4655\/Owners_-manual-R454B-Ceiling-cassette_compressed.pdf\" class=\"hvx-link\"\u003eCeiling Cassette Owner’s Manual (R454B)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/media.cooperandhunter.us\/3309\/120N--uses-and-installation-manual.pdf\" class=\"hvx-link\"\u003e120N Wire Controller — Uses \u0026amp; Installation Manual\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/media.cooperandhunter.us\/3198\/MultiZone-Combination-HYPER.pdf\" class=\"hvx-link\"\u003eMultiZone Combination Guide — Hyper\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/media.cooperandhunter.us\/3199\/MultiZone-Combination-Regular.pdf\" class=\"hvx-link\"\u003eMultiZone Combination Guide — Regular\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"hvx-desc-card\"\u003e\n\u003ch3 class=\"hvx-section-title\"\u003eImportant\u003c\/h3\u003e\n\u003cul style=\"margin: 0; padding-left: 18px;\" class=\"hvx-muted\"\u003e\n\u003cli\u003eProfessional installation is recommended.\u003c\/li\u003e\n\u003cli\u003eMatch line set sizes to the equipment: 3\/8\" liquid and 3\/4\" suction.\u003c\/li\u003e\n\u003cli\u003eVerify the dedicated circuit is sized per equipment MCA and local code.\u003c\/li\u003e\n\u003cli\u003eNeed help choosing equipment? \u003ca href=\"https:\/\/hvacsupplies.com\/pages\/contact\" class=\"hvx-link\"\u003ehvacsupplies.com\/pages\/contact\u003c\/a\u003e • \u003ca href=\"tel:+18005438933\" class=\"hvx-link\"\u003e(800) 543-8933\u003c\/a\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"hvx-desc-card hvx-faq\"\u003e\n\u003ch3 class=\"hvx-section-title\"\u003eFAQs\u003c\/h3\u003e\n\u003cdetails\u003e\n\u003csummary\u003eDoes the cassette include a condensate pump?\u003c\/summary\u003e\n\u003cp class=\"hvx-muted\"\u003eYes. CH-RSH36LCCT includes a built-in pump with float switch (20.9\" lift).\u003c\/p\u003e\n\u003c\/details\u003e\n\u003cdetails\u003e\n\u003csummary\u003eWhat line set sizes are required?\u003c\/summary\u003e\n\u003cp class=\"hvx-muted\"\u003e3\/8\" liquid line and 3\/4\" suction (gas) line.\u003c\/p\u003e\n\u003c\/details\u003e\n\u003cdetails\u003e\n\u003csummary\u003eHow cold can the outdoor unit operate in heating?\u003c\/summary\u003e\n\u003cp class=\"hvx-muted\"\u003eCH-R36LCU-230VO supports heating operation down to -13°F ambient.\u003c\/p\u003e\n\u003c\/details\u003e\n\u003cdetails\u003e\n\u003csummary\u003eCan I control the system with an app?\u003c\/summary\u003e\n\u003cp class=\"hvx-muted\"\u003eSmart Kit capability supports app control through the C\u0026amp;H platform after setup.\u003c\/p\u003e\n\u003c\/details\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e","brand":"Cooper\u0026Hunter","offers":[{"title":"No Installation","offer_id":42691112501291,"sku":"CH-RSH36LCCT + CH-R36LCU-230VO","price":3529.0,"currency_code":"USD","in_stock":true},{"title":"25FT","offer_id":42691112566827,"sku":"CH-RSH36LCCT + CH-R36LCU-230VO","price":4010.0,"currency_code":"USD","in_stock":true},{"title":"50FT","offer_id":42691112599595,"sku":"CH-RSH36LCCT + CH-R36LCU-230VO","price":4203.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0625\/5647\/1339\/files\/FourWay_Regular_Product_Hero_48_33b3a9f5-7a1c-442f-a881-e51e604eb6c3.png?v=1769199174"},{"product_id":"cooper-hunter-36-000-btu-hyper-single-zone-four-way-ceiling-cassette-w-humidity-sensor-minisplit-heat-pump-system-r454b-230v","title":"Cooper\u0026Hunter 36,000 BTU Hyper Single Zone Four-Way Ceiling Cassette w\/ Humidity Sensor Minisplit Heat Pump System R454B 230V","description":"\u003cstyle\u003e\n    :root{--hvx-golden:#FAA819;--hvx-slate:#262626;--hvx-ivory:#F4F1E6;--hvx-border:#e2e0d5;--hvx-card-bg:#ffffff;}\n    .hvx-desc{background:var(--hvx-ivory);padding:18px;border-radius:18px;font-family:\"Articulat CF\",system-ui,-apple-system,Segoe UI,Roboto,Arial,sans-serif;color:#111;}\n    .hvx-desc-header{background:linear-gradient(120deg,var(--hvx-golden),var(--hvx-slate));border-radius:16px;padding:16px 16px 14px;color:#fff;margin-bottom:14px;}\n    .hvx-eyebrow{font-size:12px;letter-spacing:.12em;text-transform:uppercase;opacity:.9;margin:0 0 6px;}\n    .hvx-title{font-family:\"Anton\",Impact,Haettenschweiler,\"Arial Narrow Bold\",sans-serif;font-size:26px;line-height:1.05;margin:0;}\n    .hvx-desc-card{background:var(--hvx-card-bg);border:1px solid var(--hvx-border);border-radius:16px;padding:14px;margin:12px 0;box-shadow:0 10px 18px rgba(0,0,0,.06);}\n    .hvx-section-title{margin:0 0 10px;font-size:13px;letter-spacing:.12em;text-transform:uppercase;display:inline-block;padding-bottom:6px;position:relative;}\n    .hvx-section-title:after{content:\"\";position:absolute;left:0;bottom:0;height:3px;width:100%;border-radius:99px;background:linear-gradient(90deg,var(--hvx-golden),var(--hvx-slate));}\n    .hvx-badges{display:flex;flex-wrap:wrap;gap:8px;margin:6px 0 10px;}\n    .hvx-badge{display:inline-flex;align-items:center;gap:6px;padding:6px 10px;border-radius:999px;border:1px solid var(--hvx-border);background:#fff;font-size:12px;font-weight:600;}\n    .hvx-grid{display:grid;grid-template-columns:repeat(3,minmax(0,1fr));gap:10px;}\n    .hvx-kv{border:1px solid var(--hvx-border);border-radius:14px;padding:10px;background:#fff;}\n    .hvx-k{font-size:12px;letter-spacing:.08em;text-transform:uppercase;color:#333;margin:0 0 6px;}\n    .hvx-v{font-size:14px;font-weight:700;margin:0;}\n    .hvx-table-wrap{overflow:auto;border-radius:14px;border:1px solid var(--hvx-border);background:#fff;}\n    table.hvx-table{width:100%;border-collapse:collapse;min-width:520px;}\n    .hvx-table th,.hvx-table td{padding:10px 12px;border-bottom:1px solid var(--hvx-border);vertical-align:top;font-size:14px;}\n    .hvx-table th{background:rgba(250,168,25,.12);text-align:left;font-size:12px;letter-spacing:.1em;text-transform:uppercase;}\n    .hvx-table tr:last-child td{border-bottom:none;}\n    .hvx-link{color:#111;text-decoration:none;border-bottom:2px solid rgba(250,168,25,.7);}\n    .hvx-link:hover{border-bottom-color:#111;}\n    .hvx-faq details{border:1px solid var(--hvx-border);border-radius:14px;background:#fff;padding:10px 12px;margin:10px 0;}\n    .hvx-faq summary{cursor:pointer;font-weight:800;}\n    .hvx-muted{color:#333;margin:6px 0 0;}\n    @media (max-width:720px){.hvx-grid{grid-template-columns:1fr;}.hvx-title{font-size:24px;}}\n  \u003c\/style\u003e\n\u003cdiv class=\"hvx-desc\"\u003e\n\u003cdiv class=\"hvx-desc-header\"\u003e\n\u003cp class=\"hvx-eyebrow\"\u003eSingle Zone • 36,000 BTU • 4-Way Ceiling Cassette • R454B • 208–230V\u003c\/p\u003e\n\u003ch2 class=\"hvx-title\"\u003eCooper\u0026amp;Hunter 36,000 BTU Hyper Single Zone Four-Way Ceiling Cassette w\/ Humidity Sensor Minisplit Heat Pump System R454B 230V\u003c\/h2\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"hvx-desc-card\"\u003e\n\u003ch3 class=\"hvx-section-title\"\u003eOverview\u003c\/h3\u003e\n\u003cp class=\"hvx-muted\"\u003eA 36K 4-way ceiling cassette pairing designed for even distribution across large areas using a 360° airflow panel. Includes a built-in condensate pump and comfort modes like turbo and sleep. Pairing with the Hyper outdoor unit supports strong low-ambient heating for demanding climates.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"hvx-desc-card\"\u003e\n\u003ch3 class=\"hvx-section-title\"\u003eHighlights\u003c\/h3\u003e\n\u003cdiv class=\"hvx-badges\"\u003e\n\u003cspan class=\"hvx-badge\"\u003eR454B Refrigerant\u003c\/span\u003e \u003cspan class=\"hvx-badge\"\u003e360° Airflow Panel\u003c\/span\u003e \u003cspan class=\"hvx-badge\"\u003eHumidity Sensor\u003c\/span\u003e \u003cspan class=\"hvx-badge\"\u003eGoldFin Coating\u003c\/span\u003e \u003cspan class=\"hvx-badge\"\u003eBuilt-In Pump\u003c\/span\u003e \u003cspan class=\"hvx-badge\"\u003eHyper Heating Outdoor\u003c\/span\u003e\n\u003c\/div\u003e\n\u003cul class=\"hvx-muted\" style=\"margin: 0 0 10px; padding-left: 18px;\"\u003e\n\u003cli\u003e360° panel and omni-directional airflow helps cover large rooms evenly.\u003c\/li\u003e\n\u003cli\u003eActivated carbon filtration support for fresher indoor air.\u003c\/li\u003e\n\u003cli\u003eAnti-cold-air heating behavior reduces drafts during heat mode.\u003c\/li\u003e\n\u003cli\u003eBuilt-in pump with float switch (20.9\" lift) for quiet condensate removal.\u003c\/li\u003e\n\u003cli\u003eMultiple fan speeds plus turbo and sleep modes for comfort control.\u003c\/li\u003e\n\u003cli\u003eHyper outdoor supports heating operation down to -22°F ambient.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cdiv class=\"hvx-grid\"\u003e\n\u003cdiv class=\"hvx-kv\"\u003e\n\u003cp class=\"hvx-k\"\u003eIndoor Model\u003c\/p\u003e\n\u003cp class=\"hvx-v\"\u003e\u003ca class=\"hvx-link\" href=\"https:\/\/hvacsupplies.com\/search?options%5Bprefix%5D=last\u0026amp;q=CH-RH36LCCT\"\u003eCH-RH36LCCT\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"hvx-kv\"\u003e\n\u003cp class=\"hvx-k\"\u003eOutdoor Model\u003c\/p\u003e\n\u003cp class=\"hvx-v\"\u003e\u003ca class=\"hvx-link\" href=\"https:\/\/hvacsupplies.com\/search?options%5Bprefix%5D=last\u0026amp;q=CH-RHP36LCU-230VO\"\u003eCH-RHP36LCU-230VO\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"hvx-kv\"\u003e\n\u003cp class=\"hvx-k\"\u003eLine Set Size\u003c\/p\u003e\n\u003cp class=\"hvx-v\"\u003e3\/8\" Liquid • 3\/4\" Gas\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"hvx-kv\"\u003e\n\u003cp class=\"hvx-k\"\u003ePower\u003c\/p\u003e\n\u003cp class=\"hvx-v\"\u003e208–230V • 1Ph • 60Hz\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"hvx-kv\"\u003e\n\u003cp class=\"hvx-k\"\u003eMax Line Length\u003c\/p\u003e\n\u003cp class=\"hvx-v\"\u003e246 ft\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"hvx-kv\"\u003e\n\u003cp class=\"hvx-k\"\u003eLow-Ambient Heating\u003c\/p\u003e\n\u003cp class=\"hvx-v\"\u003eDown to -22°F\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"hvx-desc-card\"\u003e\n\u003ch3 class=\"hvx-section-title\"\u003eWhat’s Included\u003c\/h3\u003e\n\u003cul class=\"hvx-muted\" style=\"margin: 0; padding-left: 18px;\"\u003e\n\u003cli\u003eIndoor 4-way ceiling cassette: CH-RH36LCCT\u003c\/li\u003e\n\u003cli\u003eOutdoor condenser: CH-RHP36LCU-230VO (Hyper)\u003c\/li\u003e\n\u003cli\u003eRemote control (indoor control package)\u003c\/li\u003e\n\u003cli\u003eCeiling Cassette Panel\u003c\/li\u003e\n\u003cli\u003eBuilt-in condensate pump with float switch (indoor)\u003c\/li\u003e\n\u003cli\u003eSmart Kit capability for app control (setup required)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"hvx-desc-card\"\u003e\n\u003ch3 class=\"hvx-section-title\"\u003eIndoor Specs (CH-RH36LCCT)\u003c\/h3\u003e\n\u003cdiv class=\"hvx-table-wrap\"\u003e\n\u003ctable class=\"hvx-table\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eSpec\u003c\/th\u003e\n\u003cth\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRefrigerant Type\u003c\/td\u003e\n\u003ctd\u003eR454B\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBTU Rated\u003c\/td\u003e\n\u003ctd\u003e36,000\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower\u003c\/td\u003e\n\u003ctd\u003e208–230V • 1Ph • 60Hz (Voltage Range: 187–253V)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRefrigerant Piping\u003c\/td\u003e\n\u003ctd\u003e3\/8\" Liquid • 3\/4\" Gas\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDrain Pipe Diameter\u003c\/td\u003e\n\u003ctd\u003e1\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Range\u003c\/td\u003e\n\u003ctd\u003eCooling: 60–90°F • Heating: 32–86°F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMinimum Circuit Ampacity\u003c\/td\u003e\n\u003ctd\u003e3 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax Fuse\u003c\/td\u003e\n\u003ctd\u003e15 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003cp class=\"hvx-muted\" style=\"margin-top: 10px;\"\u003eTip: If you want the full CH-RH36LCCT spec table populated (dimensions, airflow, sound, weights, efficiency), paste the JSON\/spec block for CH-RH36LCCT and I’ll drop it in.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"hvx-desc-card\"\u003e\n\u003ch3 class=\"hvx-section-title\"\u003eOutdoor Specs (CH-RHP36LCU-230VO)\u003c\/h3\u003e\n\u003cdiv class=\"hvx-table-wrap\"\u003e\n\u003ctable class=\"hvx-table\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eSpec\u003c\/th\u003e\n\u003cth\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRefrigerant Type\u003c\/td\u003e\n\u003ctd\u003eR454B\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSystem Type\u003c\/td\u003e\n\u003ctd\u003eSingle-zone unit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBTU Rated\u003c\/td\u003e\n\u003ctd\u003e36,000\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCooling Capacity (Min–Max)\u003c\/td\u003e\n\u003ctd\u003e36,000 (9,800–37,000) BTU\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHeating Capacity (Min–Max)\u003c\/td\u003e\n\u003ctd\u003e42,000 (11,000–45,500) BTU\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSEER2 \/ EER2\u003c\/td\u003e\n\u003ctd\u003e17.7 \/ 12\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHSPF2 (Region IV \/ V)\u003c\/td\u003e\n\u003ctd\u003e11.1 \/ 9.2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCOP\u003c\/td\u003e\n\u003ctd\u003e3.8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower\u003c\/td\u003e\n\u003ctd\u003e208–230V • 1Ph • 60Hz (Voltage Range: 187–253V)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax Pipe Length\u003c\/td\u003e\n\u003ctd\u003e246 ft\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax Height Difference\u003c\/td\u003e\n\u003ctd\u003e98.4 ft\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMinimum Circuit Ampacity\u003c\/td\u003e\n\u003ctd\u003e38 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax Fuse\u003c\/td\u003e\n\u003ctd\u003e40 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutdoor Airflow\u003c\/td\u003e\n\u003ctd\u003e3,001.9 CFM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutdoor Noise\u003c\/td\u003e\n\u003ctd\u003e65 dB(A)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUnit Dimensions (W×D×H)\u003c\/td\u003e\n\u003ctd\u003e38.58 × 16.34 × 38.39 in\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNet \/ Gross Weight\u003c\/td\u003e\n\u003ctd\u003e206.57 \/ 237.44 lb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAmbient Temperature\u003c\/td\u003e\n\u003ctd\u003eCooling: -22–122°F • Heating: -22–75°F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAdditional Charge\u003c\/td\u003e\n\u003ctd\u003e0.32 oz\/ft (3\/8\" liquid line)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"hvx-desc-card\"\u003e\n\u003ch3 class=\"hvx-section-title\"\u003eDocuments \u0026amp; Downloads\u003c\/h3\u003e\n\u003cul class=\"hvx-muted\" style=\"margin: 0; padding-left: 18px;\"\u003e\n\u003cli\u003e\u003ca class=\"hvx-link\" href=\"https:\/\/media.cooperandhunter.us\/4693\/CH-RHP36LCU-230VO_CH-RH36LCCT.pdf\"\u003eSubmittal Sheet: CH-RHP36LCU-230VO + CH-RH36LCCT\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca class=\"hvx-link\" href=\"https:\/\/media.cooperandhunter.us\/3960\/CH-RHP36LCU-230VO-%2B-CH-RS36LCAHU.pdf\"\u003eSubmittal Sheet: CH-RHP36LCU-230VO + CH-RS36LCAHU\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca class=\"hvx-link\" href=\"https:\/\/media.cooperandhunter.us\/4206\/CH-RHP36LCU-230VO-%2B-CH-RS36LCDT-HS.pdf\"\u003eSubmittal Sheet: CH-RHP36LCU-230VO + CH-RS36LCDT-HS\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca class=\"hvx-link\" href=\"https:\/\/media.cooperandhunter.us\/4632\/CH-RHP36LCU-230VO_CH-RSH36LCFC.pdf\"\u003eSubmittal Sheet: CH-RHP36LCU-230VO + CH-RSH36LCFC\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca class=\"hvx-link\" href=\"https:\/\/media.cooperandhunter.us\/4200\/SlimDuct-Leaflet-R454B.pdf\"\u003eSlimDuct Leaflet (R454B)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca class=\"hvx-link\" href=\"https:\/\/media.cooperandhunter.us\/4654\/Installation-manual-R454B-Ceiling-cassette_compressed.pdf\"\u003eCeiling Cassette Installation Manual (R454B)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca class=\"hvx-link\" href=\"https:\/\/media.cooperandhunter.us\/4655\/Owners_-manual-R454B-Ceiling-cassette_compressed.pdf\"\u003eCeiling Cassette Owner’s Manual (R454B)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca class=\"hvx-link\" href=\"https:\/\/media.cooperandhunter.us\/3309\/120N--uses-and-installation-manual.pdf\"\u003e120N Wire Controller — Uses \u0026amp; Installation Manual\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca class=\"hvx-link\" href=\"https:\/\/media.cooperandhunter.us\/3198\/MultiZone-Combination-HYPER.pdf\"\u003eMultiZone Combination Guide — Hyper\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca class=\"hvx-link\" href=\"https:\/\/media.cooperandhunter.us\/3199\/MultiZone-Combination-Regular.pdf\"\u003eMultiZone Combination Guide — Regular\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"hvx-desc-card\"\u003e\n\u003ch3 class=\"hvx-section-title\"\u003eImportant\u003c\/h3\u003e\n\u003cul class=\"hvx-muted\" style=\"margin: 0; padding-left: 18px;\"\u003e\n\u003cli\u003eProfessional installation is recommended.\u003c\/li\u003e\n\u003cli\u003eMatch line set sizes to the equipment: 3\/8\" liquid and 3\/4\" suction.\u003c\/li\u003e\n\u003cli\u003eVerify the dedicated circuit is sized per equipment MCA and local code.\u003c\/li\u003e\n\u003cli\u003eNeed help choosing equipment? \u003ca class=\"hvx-link\" href=\"https:\/\/hvacsupplies.com\/pages\/contact\"\u003ehvacsupplies.com\/pages\/contact\u003c\/a\u003e • \u003ca class=\"hvx-link\" href=\"tel:+18005438933\"\u003e(800) 543-8933\u003c\/a\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"hvx-desc-card hvx-faq\"\u003e\n\u003ch3 class=\"hvx-section-title\"\u003eFAQs\u003c\/h3\u003e\n\u003cdetails\u003e\n\u003csummary\u003eDoes the cassette include a condensate pump?\u003c\/summary\u003e\n\u003cp class=\"hvx-muted\"\u003eYes. Ceiling cassette models in this series include a built-in pump with float switch (20.9\" lift).\u003c\/p\u003e\n\u003c\/details\u003e\n\u003cdetails\u003e\n\u003csummary\u003eWhat line set sizes are required?\u003c\/summary\u003e\n\u003cp class=\"hvx-muted\"\u003e3\/8\" liquid line and 3\/4\" suction (gas) line.\u003c\/p\u003e\n\u003c\/details\u003e\n\u003cdetails\u003e\n\u003csummary\u003eHow cold can the Hyper outdoor unit heat?\u003c\/summary\u003e\n\u003cp class=\"hvx-muted\"\u003eCH-RHP36LCU-230VO supports heating operation down to -22°F ambient.\u003c\/p\u003e\n\u003c\/details\u003e\n\u003cdetails\u003e\n\u003csummary\u003eCan I control the system with an app?\u003c\/summary\u003e\n\u003cp class=\"hvx-muted\"\u003eSmart Kit capability supports app control through the C\u0026amp;H platform after setup.\u003c\/p\u003e\n\u003c\/details\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e","brand":"Cooper\u0026Hunter","offers":[{"title":"No Installation","offer_id":42691112697899,"sku":"CH-RH36LCCT + CH-RHP36LCU-230VO","price":4808.0,"currency_code":"USD","in_stock":true},{"title":"25FT","offer_id":42691112763435,"sku":"CH-RH36LCCT + CH-RHP36LCU-230VO","price":5289.0,"currency_code":"USD","in_stock":true},{"title":"50FT","offer_id":42691112796203,"sku":"CH-RH36LCCT + CH-RHP36LCU-230VO","price":5482.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0625\/5647\/1339\/files\/2-ZoneDuctlessMiniSplitAC_HeatPump48000BTU_26.png?v=1769199192"},{"product_id":"cooper-hunter-36-000-btu-single-zone-four-way-ceiling-cassette-w-humidity-sensor-minisplit-heat-pump-system-r454b-230v","title":"Cooper\u0026Hunter 36,000 BTU Single Zone Four-Way Ceiling Cassette w\/ Humidity Sensor Minisplit Heat Pump System R454B 230V","description":"\u003cstyle\u003e\n    :root{--hvx-golden:#FAA819;--hvx-slate:#262626;--hvx-ivory:#F4F1E6;--hvx-border:#e2e0d5;--hvx-card-bg:#ffffff;}\n    .hvx-desc{background:var(--hvx-ivory);padding:18px;border-radius:18px;font-family:\"Articulat CF\",system-ui,-apple-system,Segoe UI,Roboto,Arial,sans-serif;color:#111;}\n    .hvx-desc-header{background:linear-gradient(120deg,var(--hvx-golden),var(--hvx-slate));border-radius:16px;padding:16px 16px 14px;color:#fff;margin-bottom:14px;}\n    .hvx-eyebrow{font-size:12px;letter-spacing:.12em;text-transform:uppercase;opacity:.9;margin:0 0 6px;}\n    .hvx-title{font-family:\"Anton\",Impact,Haettenschweiler,\"Arial Narrow Bold\",sans-serif;font-size:26px;line-height:1.05;margin:0;}\n    .hvx-desc-card{background:var(--hvx-card-bg);border:1px solid var(--hvx-border);border-radius:16px;padding:14px;margin:12px 0;box-shadow:0 10px 18px rgba(0,0,0,.06);}\n    .hvx-section-title{margin:0 0 10px;font-size:13px;letter-spacing:.12em;text-transform:uppercase;display:inline-block;padding-bottom:6px;position:relative;}\n    .hvx-section-title:after{content:\"\";position:absolute;left:0;bottom:0;height:3px;width:100%;border-radius:99px;background:linear-gradient(90deg,var(--hvx-golden),var(--hvx-slate));}\n    .hvx-badges{display:flex;flex-wrap:wrap;gap:8px;margin:6px 0 10px;}\n    .hvx-badge{display:inline-flex;align-items:center;gap:6px;padding:6px 10px;border-radius:999px;border:1px solid var(--hvx-border);background:#fff;font-size:12px;font-weight:600;}\n    .hvx-grid{display:grid;grid-template-columns:repeat(3,minmax(0,1fr));gap:10px;}\n    .hvx-kv{border:1px solid var(--hvx-border);border-radius:14px;padding:10px;background:#fff;}\n    .hvx-k{font-size:12px;letter-spacing:.08em;text-transform:uppercase;color:#333;margin:0 0 6px;}\n    .hvx-v{font-size:14px;font-weight:700;margin:0;}\n    .hvx-table-wrap{overflow:auto;border-radius:14px;border:1px solid var(--hvx-border);background:#fff;}\n    table.hvx-table{width:100%;border-collapse:collapse;min-width:520px;}\n    .hvx-table th,.hvx-table td{padding:10px 12px;border-bottom:1px solid var(--hvx-border);vertical-align:top;font-size:14px;}\n    .hvx-table th{background:rgba(250,168,25,.12);text-align:left;font-size:12px;letter-spacing:.1em;text-transform:uppercase;}\n    .hvx-table tr:last-child td{border-bottom:none;}\n    .hvx-link{color:#111;text-decoration:none;border-bottom:2px solid rgba(250,168,25,.7);}\n    .hvx-link:hover{border-bottom-color:#111;}\n    .hvx-faq details{border:1px solid var(--hvx-border);border-radius:14px;background:#fff;padding:10px 12px;margin:10px 0;}\n    .hvx-faq summary{cursor:pointer;font-weight:800;}\n    .hvx-muted{color:#333;margin:6px 0 0;}\n    @media (max-width:720px){.hvx-grid{grid-template-columns:1fr;}.hvx-title{font-size:24px;}}\n  \u003c\/style\u003e\n\u003cdiv class=\"hvx-desc\"\u003e\n\u003cdiv class=\"hvx-desc-header\"\u003e\n\u003cp class=\"hvx-eyebrow\"\u003eSingle Zone • 36,000 BTU • 4-Way Ceiling Cassette • R454B • 208–230V\u003c\/p\u003e\n\u003ch2 class=\"hvx-title\"\u003eCooper\u0026amp;Hunter 36,000 BTU Single Zone Four-Way Ceiling Cassette w\/ Humidity Sensor Minisplit Heat Pump System R454B 230V\u003c\/h2\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"hvx-desc-card\"\u003e\n\u003ch3 class=\"hvx-section-title\"\u003eOverview\u003c\/h3\u003e\n\u003cp class=\"hvx-muted\"\u003eA 36K 4-way ceiling cassette pairing designed for even distribution across large areas using a 360° airflow panel. Includes a built-in condensate pump and comfort modes like turbo and sleep. Pair with CH-R36LCU-230VO for efficient inverter performance.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"hvx-desc-card\"\u003e\n\u003ch3 class=\"hvx-section-title\"\u003eHighlights\u003c\/h3\u003e\n\u003cdiv class=\"hvx-badges\"\u003e\n\u003cspan class=\"hvx-badge\"\u003eR454B Refrigerant\u003c\/span\u003e \u003cspan class=\"hvx-badge\"\u003e360° Airflow Panel\u003c\/span\u003e \u003cspan class=\"hvx-badge\"\u003eHumidity Sensor\u003c\/span\u003e \u003cspan class=\"hvx-badge\"\u003eGoldFin Coating\u003c\/span\u003e \u003cspan class=\"hvx-badge\"\u003eBuilt-In Pump\u003c\/span\u003e \u003cspan class=\"hvx-badge\"\u003eInverter Outdoor\u003c\/span\u003e\n\u003c\/div\u003e\n\u003cul style=\"margin: 0 0 10px; padding-left: 18px;\" class=\"hvx-muted\"\u003e\n\u003cli\u003e360° panel and omni-directional airflow helps cover large rooms evenly.\u003c\/li\u003e\n\u003cli\u003eActivated carbon filtration support for fresher indoor air.\u003c\/li\u003e\n\u003cli\u003eAnti-cold-air heating behavior reduces drafts during heat mode.\u003c\/li\u003e\n\u003cli\u003eBuilt-in pump with float switch (20.9\" lift) for quiet condensate removal.\u003c\/li\u003e\n\u003cli\u003eMultiple fan speeds plus turbo and sleep modes for comfort control.\u003c\/li\u003e\n\u003cli\u003eOutdoor heating operation supports down to -13°F ambient.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cdiv class=\"hvx-grid\"\u003e\n\u003cdiv class=\"hvx-kv\"\u003e\n\u003cp class=\"hvx-k\"\u003eIndoor Model\u003c\/p\u003e\n\u003cp class=\"hvx-v\"\u003e\u003ca href=\"https:\/\/hvacsupplies.com\/search?options%5Bprefix%5D=last\u0026amp;q=CH-RH36LCCT\" class=\"hvx-link\"\u003eCH-RH36LCCT\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"hvx-kv\"\u003e\n\u003cp class=\"hvx-k\"\u003eOutdoor Model\u003c\/p\u003e\n\u003cp class=\"hvx-v\"\u003e\u003ca href=\"https:\/\/hvacsupplies.com\/search?options%5Bprefix%5D=last\u0026amp;q=CH-R36LCU-230VO\" class=\"hvx-link\"\u003eCH-R36LCU-230VO\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"hvx-kv\"\u003e\n\u003cp class=\"hvx-k\"\u003eLine Set Size\u003c\/p\u003e\n\u003cp class=\"hvx-v\"\u003e3\/8\" Liquid • 3\/4\" Gas\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"hvx-kv\"\u003e\n\u003cp class=\"hvx-k\"\u003ePower\u003c\/p\u003e\n\u003cp class=\"hvx-v\"\u003e208–230V • 1Ph • 60Hz\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"hvx-kv\"\u003e\n\u003cp class=\"hvx-k\"\u003eMax Line Length\u003c\/p\u003e\n\u003cp class=\"hvx-v\"\u003e246 ft\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"hvx-kv\"\u003e\n\u003cp class=\"hvx-k\"\u003eLow-Ambient Heating\u003c\/p\u003e\n\u003cp class=\"hvx-v\"\u003eDown to -13°F\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"hvx-desc-card\"\u003e\n\u003ch3 class=\"hvx-section-title\"\u003eWhat’s Included\u003c\/h3\u003e\n\u003cul style=\"margin: 0; padding-left: 18px;\" class=\"hvx-muted\"\u003e\n\u003cli\u003eIndoor 4-way ceiling cassette: CH-RH36LCCT\u003c\/li\u003e\n\u003cli\u003eOutdoor condenser: CH-R36LCU-230VO\u003c\/li\u003e\n\u003cli\u003eRemote control (indoor control package)\u003c\/li\u003e\n\u003cli\u003eCeiling Cassette Panel\u003c\/li\u003e\n\u003cli\u003eBuilt-in condensate pump with float switch (indoor)\u003c\/li\u003e\n\u003cli\u003eSmart Kit capability for app control (setup required)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"hvx-desc-card\"\u003e\n\u003ch3 class=\"hvx-section-title\"\u003eIndoor Specs (CH-RH36LCCT)\u003c\/h3\u003e\n\u003cdiv class=\"hvx-table-wrap\"\u003e\n\u003ctable class=\"hvx-table\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eSpec\u003c\/th\u003e\n\u003cth\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRefrigerant Type\u003c\/td\u003e\n\u003ctd\u003eR454B\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBTU Rated\u003c\/td\u003e\n\u003ctd\u003e36,000\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower\u003c\/td\u003e\n\u003ctd\u003e208–230V • 1Ph • 60Hz (Voltage Range: 187–253V)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRefrigerant Piping\u003c\/td\u003e\n\u003ctd\u003e3\/8\" Liquid • 3\/4\" Gas\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDrain Pipe Diameter\u003c\/td\u003e\n\u003ctd\u003e1\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Range\u003c\/td\u003e\n\u003ctd\u003eCooling: 60–90°F • Heating: 32–86°F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMinimum Circuit Ampacity\u003c\/td\u003e\n\u003ctd\u003e3 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax Fuse\u003c\/td\u003e\n\u003ctd\u003e15 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003cp style=\"margin-top: 10px;\" class=\"hvx-muted\"\u003eTip: If you want the full CH-RH36LCCT spec table populated (dimensions, airflow, sound, weights, efficiency), paste the JSON\/spec block for CH-RH36LCCT and I’ll drop it in.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"hvx-desc-card\"\u003e\n\u003ch3 class=\"hvx-section-title\"\u003eOutdoor Specs (CH-R36LCU-230VO)\u003c\/h3\u003e\n\u003cdiv class=\"hvx-table-wrap\"\u003e\n\u003ctable class=\"hvx-table\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eSpec\u003c\/th\u003e\n\u003cth\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRefrigerant Type\u003c\/td\u003e\n\u003ctd\u003eR454B\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSystem Type\u003c\/td\u003e\n\u003ctd\u003eSingle-zone unit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBTU Rated\u003c\/td\u003e\n\u003ctd\u003e36,000\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCooling Capacity (Min–Max)\u003c\/td\u003e\n\u003ctd\u003e36,000 (7,900–42,500) BTU\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHeating Capacity (Min–Max)\u003c\/td\u003e\n\u003ctd\u003e40,000 (8,100–43,500) BTU\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSEER2 \/ EER2\u003c\/td\u003e\n\u003ctd\u003e18.7 \/ 10.1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHSPF2 (Region IV \/ V)\u003c\/td\u003e\n\u003ctd\u003e10.2 \/ 7.8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCOP\u003c\/td\u003e\n\u003ctd\u003e3.7\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAHRI\u003c\/td\u003e\n\u003ctd\u003e207742340\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower\u003c\/td\u003e\n\u003ctd\u003e208–230V • 1Ph • 60Hz (Voltage Range: 187–253V)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax Pipe Length\u003c\/td\u003e\n\u003ctd\u003e246 ft\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax Height Difference\u003c\/td\u003e\n\u003ctd\u003e98.4 ft\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMinimum Circuit Ampacity\u003c\/td\u003e\n\u003ctd\u003e33 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax Fuse\u003c\/td\u003e\n\u003ctd\u003e35 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutdoor Airflow\u003c\/td\u003e\n\u003ctd\u003e2,413.3 CFM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutdoor Noise\u003c\/td\u003e\n\u003ctd\u003e63 dB(A)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUnit Dimensions (W×D×H)\u003c\/td\u003e\n\u003ctd\u003e37.24 × 16.14 × 31.89 in\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNet \/ Gross Weight\u003c\/td\u003e\n\u003ctd\u003e152.34 \/ 162.48 lb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAmbient Temperature\u003c\/td\u003e\n\u003ctd\u003eCooling: -13–122°F • Heating: -13–75°F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAdditional Charge\u003c\/td\u003e\n\u003ctd\u003e0.32 oz\/ft (3\/8\" liquid line)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"hvx-desc-card\"\u003e\n\u003ch3 class=\"hvx-section-title\"\u003eDocuments \u0026amp; Downloads\u003c\/h3\u003e\n\u003cul style=\"margin: 0; padding-left: 18px;\" class=\"hvx-muted\"\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/media.cooperandhunter.us\/4689\/CH-R36LCU-230VO_CH-RH36LCCT.pdf\" class=\"hvx-link\"\u003eSubmittal Sheet: CH-R36LCU-230VO + CH-RH36LCCT\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/media.cooperandhunter.us\/4213\/CH-R36LCU-230VO-%2B-CH-RS36LCDT-HS.pdf\" class=\"hvx-link\"\u003eSubmittal Sheet: CH-R36LCU-230VO + CH-RS36LCDT-HS\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/media.cooperandhunter.us\/4627\/CH-R36LCU-230VO_CH-RSH36LCFC.pdf\" class=\"hvx-link\"\u003eSubmittal Sheet: CH-R36LCU-230VO + CH-RSH36LCFC\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/media.cooperandhunter.us\/4690\/CH-R36LCU-230VO_CH-RSH36LCCT.pdf\" class=\"hvx-link\"\u003eSubmittal Sheet: CH-R36LCU-230VO + CH-RSH36LCCT\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/media.cooperandhunter.us\/4200\/SlimDuct-Leaflet-R454B.pdf\" class=\"hvx-link\"\u003eSlimDuct Leaflet (R454B)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/media.cooperandhunter.us\/4654\/Installation-manual-R454B-Ceiling-cassette_compressed.pdf\" class=\"hvx-link\"\u003eCeiling Cassette Installation Manual (R454B)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/media.cooperandhunter.us\/4655\/Owners_-manual-R454B-Ceiling-cassette_compressed.pdf\" class=\"hvx-link\"\u003eCeiling Cassette Owner’s Manual (R454B)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/media.cooperandhunter.us\/3309\/120N--uses-and-installation-manual.pdf\" class=\"hvx-link\"\u003e120N Wire Controller — Uses \u0026amp; Installation Manual\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/media.cooperandhunter.us\/3198\/MultiZone-Combination-HYPER.pdf\" class=\"hvx-link\"\u003eMultiZone Combination Guide — Hyper\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/media.cooperandhunter.us\/3199\/MultiZone-Combination-Regular.pdf\" class=\"hvx-link\"\u003eMultiZone Combination Guide — Regular\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"hvx-desc-card\"\u003e\n\u003ch3 class=\"hvx-section-title\"\u003eImportant\u003c\/h3\u003e\n\u003cul style=\"margin: 0; padding-left: 18px;\" class=\"hvx-muted\"\u003e\n\u003cli\u003eProfessional installation is recommended.\u003c\/li\u003e\n\u003cli\u003eMatch line set sizes to the equipment: 3\/8\" liquid and 3\/4\" suction.\u003c\/li\u003e\n\u003cli\u003eVerify the dedicated circuit is sized per equipment MCA and local code.\u003c\/li\u003e\n\u003cli\u003eNeed help choosing equipment? \u003ca href=\"https:\/\/hvacsupplies.com\/pages\/contact\" class=\"hvx-link\"\u003ehvacsupplies.com\/pages\/contact\u003c\/a\u003e • \u003ca href=\"tel:+18005438933\" class=\"hvx-link\"\u003e(800) 543-8933\u003c\/a\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"hvx-desc-card hvx-faq\"\u003e\n\u003ch3 class=\"hvx-section-title\"\u003eFAQs\u003c\/h3\u003e\n\u003cdetails\u003e\n\u003csummary\u003eDoes the cassette include a condensate pump?\u003c\/summary\u003e\n\u003cp class=\"hvx-muted\"\u003eYes. Ceiling cassette models in this series include a built-in pump with float switch (20.9\" lift).\u003c\/p\u003e\n\u003c\/details\u003e\n\u003cdetails\u003e\n\u003csummary\u003eWhat line set sizes are required?\u003c\/summary\u003e\n\u003cp class=\"hvx-muted\"\u003e3\/8\" liquid line and 3\/4\" suction (gas) line.\u003c\/p\u003e\n\u003c\/details\u003e\n\u003cdetails\u003e\n\u003csummary\u003eHow cold can the outdoor unit operate in heating?\u003c\/summary\u003e\n\u003cp class=\"hvx-muted\"\u003eCH-R36LCU-230VO supports heating operation down to -13°F ambient.\u003c\/p\u003e\n\u003c\/details\u003e\n\u003cdetails\u003e\n\u003csummary\u003eCan I control the system with an app?\u003c\/summary\u003e\n\u003cp class=\"hvx-muted\"\u003eSmart Kit capability supports app control through the C\u0026amp;H platform after setup.\u003c\/p\u003e\n\u003c\/details\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e","brand":"Cooper\u0026Hunter","offers":[{"title":"No Installation","offer_id":42691112828971,"sku":"CH-RH36LCCT + CH-R36LCU-230VO","price":3430.0,"currency_code":"USD","in_stock":true},{"title":"25FT","offer_id":42691112894507,"sku":"CH-RH36LCCT + CH-R36LCU-230VO","price":3911.0,"currency_code":"USD","in_stock":true},{"title":"50FT","offer_id":42691112927275,"sku":"CH-RH36LCCT + CH-R36LCU-230VO","price":4104.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0625\/5647\/1339\/files\/FourWay_Regular_Product_Hero_48_33b3a9f5-7a1c-442f-a881-e51e604eb6c3.png?v=1769199174"},{"product_id":"cooper-hunter-48-000-btu-hyper-pro-single-zone-four-way-ceiling-cassette-w-refrigerant-humidity-sensor-minisplit-heat-pump-system-r454b-230v","title":"Cooper\u0026Hunter 48,000 BTU Hyper Pro Single Zone Four-Way Ceiling Cassette w\/ Refrigerant \u0026 Humidity Sensor Minisplit Heat Pump System R454B 230V","description":"\u003cstyle\u003e\n    :root{--hvx-golden:#FAA819;--hvx-slate:#262626;--hvx-ivory:#F4F1E6;--hvx-border:#e2e0d5;--hvx-card-bg:#ffffff;}\n    .hvx-desc{background:var(--hvx-ivory);padding:18px;border-radius:18px;font-family:\"Articulat CF\",system-ui,-apple-system,Segoe UI,Roboto,Arial,sans-serif;color:#111;}\n    .hvx-desc-header{background:linear-gradient(120deg,var(--hvx-golden),var(--hvx-slate));border-radius:16px;padding:16px 16px 14px;color:#fff;margin-bottom:14px;}\n    .hvx-eyebrow{font-size:12px;letter-spacing:.12em;text-transform:uppercase;opacity:.9;margin:0 0 6px;}\n    .hvx-title{font-family:\"Anton\",Impact,Haettenschweiler,\"Arial Narrow Bold\",sans-serif;font-size:26px;line-height:1.05;margin:0;}\n    .hvx-desc-card{background:var(--hvx-card-bg);border:1px solid var(--hvx-border);border-radius:16px;padding:14px;margin:12px 0;box-shadow:0 10px 18px rgba(0,0,0,.06);}\n    .hvx-section-title{margin:0 0 10px;font-size:13px;letter-spacing:.12em;text-transform:uppercase;display:inline-block;padding-bottom:6px;position:relative;}\n    .hvx-section-title:after{content:\"\";position:absolute;left:0;bottom:0;height:3px;width:100%;border-radius:99px;background:linear-gradient(90deg,var(--hvx-golden),var(--hvx-slate));}\n    .hvx-badges{display:flex;flex-wrap:wrap;gap:8px;margin:6px 0 10px;}\n    .hvx-badge{display:inline-flex;align-items:center;gap:6px;padding:6px 10px;border-radius:999px;border:1px solid var(--hvx-border);background:#fff;font-size:12px;font-weight:600;}\n    .hvx-grid{display:grid;grid-template-columns:repeat(3,minmax(0,1fr));gap:10px;}\n    .hvx-kv{border:1px solid var(--hvx-border);border-radius:14px;padding:10px;background:#fff;}\n    .hvx-k{font-size:12px;letter-spacing:.08em;text-transform:uppercase;color:#333;margin:0 0 6px;}\n    .hvx-v{font-size:14px;font-weight:700;margin:0;}\n    .hvx-table-wrap{overflow:auto;border-radius:14px;border:1px solid var(--hvx-border);background:#fff;}\n    table.hvx-table{width:100%;border-collapse:collapse;min-width:520px;}\n    .hvx-table th,.hvx-table td{padding:10px 12px;border-bottom:1px solid var(--hvx-border);vertical-align:top;font-size:14px;}\n    .hvx-table th{background:rgba(250,168,25,.12);text-align:left;font-size:12px;letter-spacing:.1em;text-transform:uppercase;}\n    .hvx-table tr:last-child td{border-bottom:none;}\n    .hvx-link{color:#111;text-decoration:none;border-bottom:2px solid rgba(250,168,25,.7);}\n    .hvx-link:hover{border-bottom-color:#111;}\n    .hvx-faq details{border:1px solid var(--hvx-border);border-radius:14px;background:#fff;padding:10px 12px;margin:10px 0;}\n    .hvx-faq summary{cursor:pointer;font-weight:800;}\n    .hvx-muted{color:#333;margin:6px 0 0;}\n    @media (max-width:720px){.hvx-grid{grid-template-columns:1fr;}.hvx-title{font-size:24px;}}\n  \u003c\/style\u003e\n\u003cdiv class=\"hvx-desc\"\u003e\n\u003cdiv class=\"hvx-desc-header\"\u003e\n\u003cp class=\"hvx-eyebrow\"\u003eSingle Zone • 48,000 BTU • Ceiling Cassette PRO • R454B • 208–230V\u003c\/p\u003e\n\u003ch2 class=\"hvx-title\"\u003eCooper\u0026amp;Hunter 48,000 BTU Hyper Pro Single Zone Four-Way Ceiling Cassette w\/ Refrigerant \u0026amp; Humidity Sensor Minisplit Heat Pump System R454B 230V\u003c\/h2\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"hvx-desc-card\"\u003e\n\u003ch3 class=\"hvx-section-title\"\u003eOverview\u003c\/h3\u003e\n\u003cp class=\"hvx-muted\"\u003eHigh-capacity 48K ceiling cassette system for large residential and light commercial spaces. The CH-RSH48LCCT uses a 360° airflow panel for even distribution, includes a built-in condensate pump, and adds refrigerant leakage detection plus self-diagnosis. Pairing with the Hyper outdoor unit supports low-ambient heating capability for demanding climates.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"hvx-desc-card\"\u003e\n\u003ch3 class=\"hvx-section-title\"\u003eHighlights\u003c\/h3\u003e\n\u003cdiv class=\"hvx-badges\"\u003e\n\u003cspan class=\"hvx-badge\"\u003eR454B Refrigerant\u003c\/span\u003e \u003cspan class=\"hvx-badge\"\u003e360° Airflow Panel\u003c\/span\u003e \u003cspan class=\"hvx-badge\"\u003eLeak Detection (RSH)\u003c\/span\u003e \u003cspan class=\"hvx-badge\"\u003eHumidity Sensor\u003c\/span\u003e \u003cspan class=\"hvx-badge\"\u003eGoldFin Coating\u003c\/span\u003e \u003cspan class=\"hvx-badge\"\u003eBuilt-In Pump\u003c\/span\u003e \u003cspan class=\"hvx-badge\"\u003eHyper Heating Outdoor\u003c\/span\u003e\n\u003c\/div\u003e\n\u003cul style=\"margin: 0 0 10px; padding-left: 18px;\" class=\"hvx-muted\"\u003e\n\u003cli\u003e360° panel and omni-directional airflow help cover large rooms evenly.\u003c\/li\u003e\n\u003cli\u003eActivated carbon filtration support for fresher indoor air.\u003c\/li\u003e\n\u003cli\u003eAnti-cold-air heating behavior reduces drafts during heat mode.\u003c\/li\u003e\n\u003cli\u003eRefrigerant leakage detection and self-diagnosis features for added protection.\u003c\/li\u003e\n\u003cli\u003eBuilt-in pump with float switch (20.9\" lift) for quiet condensate removal.\u003c\/li\u003e\n\u003cli\u003eHyper outdoor supports heating operation down to -22°F ambient.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cdiv class=\"hvx-grid\"\u003e\n\u003cdiv class=\"hvx-kv\"\u003e\n\u003cp class=\"hvx-k\"\u003eIndoor Model\u003c\/p\u003e\n\u003cp class=\"hvx-v\"\u003e\u003ca href=\"https:\/\/hvacsupplies.com\/search?options%5Bprefix%5D=last\u0026amp;q=CH-RSH48LCCT\" class=\"hvx-link\"\u003eCH-RSH48LCCT\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"hvx-kv\"\u003e\n\u003cp class=\"hvx-k\"\u003eOutdoor Model\u003c\/p\u003e\n\u003cp class=\"hvx-v\"\u003e\u003ca href=\"https:\/\/hvacsupplies.com\/search?options%5Bprefix%5D=last\u0026amp;q=CH-RHP48LCU-230VO\" class=\"hvx-link\"\u003eCH-RHP48LCU-230VO\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"hvx-kv\"\u003e\n\u003cp class=\"hvx-k\"\u003eLine Set Size\u003c\/p\u003e\n\u003cp class=\"hvx-v\"\u003e3\/8\" Liquid • 3\/4\" Gas\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"hvx-kv\"\u003e\n\u003cp class=\"hvx-k\"\u003ePower\u003c\/p\u003e\n\u003cp class=\"hvx-v\"\u003e208–230V • 1Ph • 60Hz\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"hvx-kv\"\u003e\n\u003cp class=\"hvx-k\"\u003eMax Line Length\u003c\/p\u003e\n\u003cp class=\"hvx-v\"\u003e246 ft\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"hvx-kv\"\u003e\n\u003cp class=\"hvx-k\"\u003eLow-Ambient Heating\u003c\/p\u003e\n\u003cp class=\"hvx-v\"\u003eDown to -22°F\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"hvx-desc-card\"\u003e\n\u003ch3 class=\"hvx-section-title\"\u003eWhat’s Included\u003c\/h3\u003e\n\u003cul style=\"margin: 0; padding-left: 18px;\" class=\"hvx-muted\"\u003e\n\u003cli\u003eIndoor 4-way ceiling cassette: CH-RSH48LCCT\u003c\/li\u003e\n\u003cli\u003eOutdoor condenser: CH-RHP48LCU-230VO (Hyper)\u003c\/li\u003e\n\u003cli\u003eRemote control (indoor control package)\u003c\/li\u003e\n\u003cli\u003eCeiling Cassette Panel\u003c\/li\u003e\n\u003cli\u003eBuilt-in condensate pump with float switch (indoor)\u003c\/li\u003e\n\u003cli\u003eSmart Kit capability for app control (setup required)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"hvx-desc-card\"\u003e\n\u003ch3 class=\"hvx-section-title\"\u003eIndoor Specs (CH-RSH48LCCT)\u003c\/h3\u003e\n\u003cdiv class=\"hvx-table-wrap\"\u003e\n\u003ctable class=\"hvx-table\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eSpec\u003c\/th\u003e\n\u003cth\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRefrigerant Type\u003c\/td\u003e\n\u003ctd\u003eR454B\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSystem Type\u003c\/td\u003e\n\u003ctd\u003eSingle Zone\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBTU Rated\u003c\/td\u003e\n\u003ctd\u003e48,000\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower\u003c\/td\u003e\n\u003ctd\u003e208–230V • 1Ph • 60Hz (Voltage Range: 187–253V)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSEER2 \/ EER2\u003c\/td\u003e\n\u003ctd\u003e18 \/ 10\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDehumidification\u003c\/td\u003e\n\u003ctd\u003e12.96 pints\/day\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIndoor Airflow (CFM)\u003c\/td\u003e\n\u003ctd\u003e1,236.1 \/ 1,124.2 \/ 1,018.3 \/ 800.5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNoise (dB(A))\u003c\/td\u003e\n\u003ctd\u003e52 \/ 49.5 \/ 41.5 (H\/M\/L)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUnit Dimensions (W×D×H)\u003c\/td\u003e\n\u003ctd\u003e32.68 × 32.68 × 11.30 in\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNet \/ Gross Weight\u003c\/td\u003e\n\u003ctd\u003e64.59 \/ 76.06 lb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRefrigerant Piping\u003c\/td\u003e\n\u003ctd\u003e3\/8\" Liquid • 3\/4\" Gas\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDrain Pipe Diameter\u003c\/td\u003e\n\u003ctd\u003e1\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Range\u003c\/td\u003e\n\u003ctd\u003eCooling: 60–90°F • Heating: 32–86°F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMinimum Circuit Ampacity\u003c\/td\u003e\n\u003ctd\u003e3 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax Fuse\u003c\/td\u003e\n\u003ctd\u003e15 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePacking Dimensions (WxDxH)\u003c\/td\u003e\n\u003ctd\u003e35.83 × 35.83 × 12.99 in\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"hvx-desc-card\"\u003e\n\u003ch3 class=\"hvx-section-title\"\u003eOutdoor Specs (CH-RHP48LCU-230VO)\u003c\/h3\u003e\n\u003cdiv class=\"hvx-table-wrap\"\u003e\n\u003ctable class=\"hvx-table\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eSpec\u003c\/th\u003e\n\u003cth\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRefrigerant Type\u003c\/td\u003e\n\u003ctd\u003eR454B\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSystem Type\u003c\/td\u003e\n\u003ctd\u003eSingle-zone unit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBTU Rated\u003c\/td\u003e\n\u003ctd\u003e48,000\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCooling Capacity (Min–Max)\u003c\/td\u003e\n\u003ctd\u003e48,000 (11,000–56,500) BTU\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHeating Capacity (Min–Max)\u003c\/td\u003e\n\u003ctd\u003e52,000 (11,200–60,000) BTU\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSEER2 \/ EER2\u003c\/td\u003e\n\u003ctd\u003e16.7 \/ 10.4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHSPF2 (Region IV \/ V)\u003c\/td\u003e\n\u003ctd\u003e10.8 \/ 8.8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCOP\u003c\/td\u003e\n\u003ctd\u003e3.6\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower\u003c\/td\u003e\n\u003ctd\u003e208–230V • 1Ph • 60Hz (Voltage Range: 187–253V)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax Pipe Length\u003c\/td\u003e\n\u003ctd\u003e246 ft\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax Height Difference\u003c\/td\u003e\n\u003ctd\u003e98.4 ft\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMinimum Circuit Ampacity\u003c\/td\u003e\n\u003ctd\u003e44 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax Fuse\u003c\/td\u003e\n\u003ctd\u003e45 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutdoor Airflow\u003c\/td\u003e\n\u003ctd\u003e4,237.9 CFM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutdoor Noise\u003c\/td\u003e\n\u003ctd\u003e65 dB(A)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUnit Dimensions (W×D×H)\u003c\/td\u003e\n\u003ctd\u003e37.48 × 16.34 × 52.48 in\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNet \/ Gross Weight\u003c\/td\u003e\n\u003ctd\u003e208.78 \/ 239.86 lb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAmbient Temperature\u003c\/td\u003e\n\u003ctd\u003eCooling: -22–122°F • Heating: -22–75°F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAdditional Charge\u003c\/td\u003e\n\u003ctd\u003e0.32 oz\/ft (3\/8\" liquid line)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"hvx-desc-card\"\u003e\n\u003ch3 class=\"hvx-section-title\"\u003eDocuments \u0026amp; Downloads\u003c\/h3\u003e\n\u003cul style=\"margin: 0; padding-left: 18px;\" class=\"hvx-muted\"\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/media.cooperandhunter.us\/4696\/CH-RHP48LCU-230VO_CH-RSH48LCCT.pdf\" class=\"hvx-link\"\u003eSubmittal Sheet: CH-RHP48LCU-230VO + CH-RSH48LCCT\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/media.cooperandhunter.us\/4692\/CH-R48LCU-230VO_CH-RSH48LCCT.pdf\" class=\"hvx-link\"\u003eSubmittal Sheet: CH-R48LCU-230VO + CH-RSH48LCCT\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/media.cooperandhunter.us\/4207\/CH-RHP48LCU-230VO-%2B-CH-RS48LCDT-HS.pdf\" class=\"hvx-link\"\u003eSubmittal Sheet: CH-RHP48LCU-230VO + CH-RS48LCDT-HS\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/media.cooperandhunter.us\/4633\/CH-RHP48LCU-230VO_CH-RSH48LCFC.pdf\" class=\"hvx-link\"\u003eSubmittal Sheet: CH-RHP48LCU-230VO + CH-RSH48LCFC\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/media.cooperandhunter.us\/4695\/CH-RHP48LCU-230VO_CH-RH48LCCT.pdf\" class=\"hvx-link\"\u003eSubmittal Sheet: CH-RHP48LCU-230VO + CH-RH48LCCT\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/media.cooperandhunter.us\/4200\/SlimDuct-Leaflet-R454B.pdf\" class=\"hvx-link\"\u003eSlimDuct Leaflet (R454B)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/media.cooperandhunter.us\/4654\/Installation-manual-R454B-Ceiling-cassette_compressed.pdf\" class=\"hvx-link\"\u003eCeiling Cassette Installation Manual (R454B)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/media.cooperandhunter.us\/4655\/Owners_-manual-R454B-Ceiling-cassette_compressed.pdf\" class=\"hvx-link\"\u003eCeiling Cassette Owner’s Manual (R454B)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/media.cooperandhunter.us\/3309\/120N--uses-and-installation-manual.pdf\" class=\"hvx-link\"\u003e120N Wire Controller — Uses \u0026amp; Installation Manual\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/media.cooperandhunter.us\/3198\/MultiZone-Combination-HYPER.pdf\" class=\"hvx-link\"\u003eMultiZone Combination Guide — Hyper\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/media.cooperandhunter.us\/3199\/MultiZone-Combination-Regular.pdf\" class=\"hvx-link\"\u003eMultiZone Combination Guide — Regular\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"hvx-desc-card\"\u003e\n\u003ch3 class=\"hvx-section-title\"\u003eImportant\u003c\/h3\u003e\n\u003cul style=\"margin: 0; padding-left: 18px;\" class=\"hvx-muted\"\u003e\n\u003cli\u003eProfessional installation is recommended.\u003c\/li\u003e\n\u003cli\u003eMatch line set sizes to the equipment: 3\/8\" liquid and 3\/4\" suction.\u003c\/li\u003e\n\u003cli\u003eVerify the dedicated circuit is sized per equipment MCA and local code.\u003c\/li\u003e\n\u003cli\u003eNeed help choosing equipment? \u003ca href=\"https:\/\/hvacsupplies.com\/pages\/contact\" class=\"hvx-link\"\u003ehvacsupplies.com\/pages\/contact\u003c\/a\u003e • \u003ca href=\"tel:+18005438933\" class=\"hvx-link\"\u003e(800) 543-8933\u003c\/a\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"hvx-desc-card hvx-faq\"\u003e\n\u003ch3 class=\"hvx-section-title\"\u003eFAQs\u003c\/h3\u003e\n\u003cdetails\u003e\n\u003csummary\u003eDoes the cassette include a condensate pump?\u003c\/summary\u003e\n\u003cp class=\"hvx-muted\"\u003eYes. CH-RSH48LCCT includes a built-in pump with float switch (20.9\" lift).\u003c\/p\u003e\n\u003c\/details\u003e\n\u003cdetails\u003e\n\u003csummary\u003eWhat line set sizes are required?\u003c\/summary\u003e\n\u003cp class=\"hvx-muted\"\u003e3\/8\" liquid line and 3\/4\" suction (gas) line.\u003c\/p\u003e\n\u003c\/details\u003e\n\u003cdetails\u003e\n\u003csummary\u003eHow cold can the Hyper outdoor unit heat?\u003c\/summary\u003e\n\u003cp class=\"hvx-muted\"\u003eCH-RHP48LCU-230VO supports heating operation down to -22°F ambient.\u003c\/p\u003e\n\u003c\/details\u003e\n\u003cdetails\u003e\n\u003csummary\u003eCan I control the system with an app?\u003c\/summary\u003e\n\u003cp class=\"hvx-muted\"\u003eSmart Kit capability supports app control through the C\u0026amp;H platform after setup.\u003c\/p\u003e\n\u003c\/details\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e","brand":"Cooper\u0026Hunter","offers":[{"title":"No Installation","offer_id":42691124133931,"sku":"CH-RSH48LCCT + CH-RHP48LCU-230VO","price":5362.0,"currency_code":"USD","in_stock":true},{"title":"25FT","offer_id":42691124166699,"sku":"CH-RSH48LCCT + CH-RHP48LCU-230VO","price":5843.0,"currency_code":"USD","in_stock":true},{"title":"50FT","offer_id":42691124199467,"sku":"CH-RSH48LCCT + CH-RHP48LCU-230VO","price":6036.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0625\/5647\/1339\/files\/2-ZoneDuctlessMiniSplitAC_HeatPump48000BTU_25.png?v=1769198682"},{"product_id":"cooper-hunter-48-000-btu-pro-single-zone-four-way-ceiling-cassette-w-refrigerant-humidity-sensor-minisplit-heat-pump-system-r454b-230v","title":"Cooper\u0026Hunter 48,000 BTU Pro Single Zone Four-Way Ceiling Cassette w\/ Refrigerant \u0026 Humidity Sensor Minisplit Heat Pump System R454B 230V","description":"\u003cstyle\u003e\n    :root{--hvx-golden:#FAA819;--hvx-slate:#262626;--hvx-ivory:#F4F1E6;--hvx-border:#e2e0d5;--hvx-card-bg:#ffffff;}\n    .hvx-desc{background:var(--hvx-ivory);padding:18px;border-radius:18px;font-family:\"Articulat CF\",system-ui,-apple-system,Segoe UI,Roboto,Arial,sans-serif;color:#111;}\n    .hvx-desc-header{background:linear-gradient(120deg,var(--hvx-golden),var(--hvx-slate));border-radius:16px;padding:16px 16px 14px;color:#fff;margin-bottom:14px;}\n    .hvx-eyebrow{font-size:12px;letter-spacing:.12em;text-transform:uppercase;opacity:.9;margin:0 0 6px;}\n    .hvx-title{font-family:\"Anton\",Impact,Haettenschweiler,\"Arial Narrow Bold\",sans-serif;font-size:26px;line-height:1.05;margin:0;}\n    .hvx-desc-card{background:var(--hvx-card-bg);border:1px solid var(--hvx-border);border-radius:16px;padding:14px;margin:12px 0;box-shadow:0 10px 18px rgba(0,0,0,.06);}\n    .hvx-section-title{margin:0 0 10px;font-size:13px;letter-spacing:.12em;text-transform:uppercase;display:inline-block;padding-bottom:6px;position:relative;}\n    .hvx-section-title:after{content:\"\";position:absolute;left:0;bottom:0;height:3px;width:100%;border-radius:99px;background:linear-gradient(90deg,var(--hvx-golden),var(--hvx-slate));}\n    .hvx-badges{display:flex;flex-wrap:wrap;gap:8px;margin:6px 0 10px;}\n    .hvx-badge{display:inline-flex;align-items:center;gap:6px;padding:6px 10px;border-radius:999px;border:1px solid var(--hvx-border);background:#fff;font-size:12px;font-weight:600;}\n    .hvx-grid{display:grid;grid-template-columns:repeat(3,minmax(0,1fr));gap:10px;}\n    .hvx-kv{border:1px solid var(--hvx-border);border-radius:14px;padding:10px;background:#fff;}\n    .hvx-k{font-size:12px;letter-spacing:.08em;text-transform:uppercase;color:#333;margin:0 0 6px;}\n    .hvx-v{font-size:14px;font-weight:700;margin:0;}\n    .hvx-table-wrap{overflow:auto;border-radius:14px;border:1px solid var(--hvx-border);background:#fff;}\n    table.hvx-table{width:100%;border-collapse:collapse;min-width:520px;}\n    .hvx-table th,.hvx-table td{padding:10px 12px;border-bottom:1px solid var(--hvx-border);vertical-align:top;font-size:14px;}\n    .hvx-table th{background:rgba(250,168,25,.12);text-align:left;font-size:12px;letter-spacing:.1em;text-transform:uppercase;}\n    .hvx-table tr:last-child td{border-bottom:none;}\n    .hvx-link{color:#111;text-decoration:none;border-bottom:2px solid rgba(250,168,25,.7);}\n    .hvx-link:hover{border-bottom-color:#111;}\n    .hvx-faq details{border:1px solid var(--hvx-border);border-radius:14px;background:#fff;padding:10px 12px;margin:10px 0;}\n    .hvx-faq summary{cursor:pointer;font-weight:800;}\n    .hvx-muted{color:#333;margin:6px 0 0;}\n    @media (max-width:720px){.hvx-grid{grid-template-columns:1fr;}.hvx-title{font-size:24px;}}\n  \u003c\/style\u003e\n\u003cdiv class=\"hvx-desc\"\u003e\n\u003cdiv class=\"hvx-desc-header\"\u003e\n\u003cp class=\"hvx-eyebrow\"\u003eSingle Zone • 48,000 BTU • Ceiling Cassette PRO • R454B • 208–230V\u003c\/p\u003e\n\u003ch2 class=\"hvx-title\"\u003eCooper\u0026amp;Hunter 48,000 BTU Pro Single Zone Four-Way Ceiling Cassette w\/ Refrigerant \u0026amp; Humidity Sensor Minisplit Heat Pump System R454B 230V\u003c\/h2\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"hvx-desc-card\"\u003e\n\u003ch3 class=\"hvx-section-title\"\u003eOverview\u003c\/h3\u003e\n\u003cp class=\"hvx-muted\"\u003e48K ceiling cassette system for large spaces. The CH-RSH48LCCT delivers wide coverage with a 360° airflow panel, includes a built-in condensate pump, and adds refrigerant leakage detection plus self-diagnosis. Pair with CH-R48LCU-230VO for efficient inverter performance and broad operating range.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"hvx-desc-card\"\u003e\n\u003ch3 class=\"hvx-section-title\"\u003eHighlights\u003c\/h3\u003e\n\u003cdiv class=\"hvx-badges\"\u003e\n\u003cspan class=\"hvx-badge\"\u003eR454B Refrigerant\u003c\/span\u003e \u003cspan class=\"hvx-badge\"\u003e360° Airflow Panel\u003c\/span\u003e \u003cspan class=\"hvx-badge\"\u003eLeak Detection (RSH)\u003c\/span\u003e \u003cspan class=\"hvx-badge\"\u003eHumidity Sensor\u003c\/span\u003e \u003cspan class=\"hvx-badge\"\u003eGoldFin Coating\u003c\/span\u003e \u003cspan class=\"hvx-badge\"\u003eBuilt-In Pump\u003c\/span\u003e \u003cspan class=\"hvx-badge\"\u003eInverter Outdoor\u003c\/span\u003e\n\u003c\/div\u003e\n\u003cul class=\"hvx-muted\" style=\"margin: 0 0 10px; padding-left: 18px;\"\u003e\n\u003cli\u003e360° panel and omni-directional airflow help cover large rooms evenly.\u003c\/li\u003e\n\u003cli\u003eActivated carbon filtration support for fresher indoor air.\u003c\/li\u003e\n\u003cli\u003eAnti-cold-air heating behavior reduces drafts during heat mode.\u003c\/li\u003e\n\u003cli\u003eRefrigerant leakage detection and self-diagnosis features for added protection.\u003c\/li\u003e\n\u003cli\u003eBuilt-in pump with float switch (20.9\" lift) for quiet condensate removal.\u003c\/li\u003e\n\u003cli\u003eOutdoor heating operation supports down to -13°F ambient.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cdiv class=\"hvx-grid\"\u003e\n\u003cdiv class=\"hvx-kv\"\u003e\n\u003cp class=\"hvx-k\"\u003eIndoor Model\u003c\/p\u003e\n\u003cp class=\"hvx-v\"\u003e\u003ca class=\"hvx-link\" href=\"https:\/\/hvacsupplies.com\/search?options%5Bprefix%5D=last\u0026amp;q=CH-RSH48LCCT\"\u003eCH-RSH48LCCT\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"hvx-kv\"\u003e\n\u003cp class=\"hvx-k\"\u003eOutdoor Model\u003c\/p\u003e\n\u003cp class=\"hvx-v\"\u003e\u003ca class=\"hvx-link\" href=\"https:\/\/hvacsupplies.com\/search?options%5Bprefix%5D=last\u0026amp;q=CH-R48LCU-230VO\"\u003eCH-R48LCU-230VO\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"hvx-kv\"\u003e\n\u003cp class=\"hvx-k\"\u003eLine Set Size\u003c\/p\u003e\n\u003cp class=\"hvx-v\"\u003e3\/8\" Liquid • 3\/4\" Gas\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"hvx-kv\"\u003e\n\u003cp class=\"hvx-k\"\u003ePower\u003c\/p\u003e\n\u003cp class=\"hvx-v\"\u003e208–230V • 1Ph • 60Hz\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"hvx-kv\"\u003e\n\u003cp class=\"hvx-k\"\u003eMax Line Length\u003c\/p\u003e\n\u003cp class=\"hvx-v\"\u003e246 ft\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"hvx-kv\"\u003e\n\u003cp class=\"hvx-k\"\u003eLow-Ambient Heating\u003c\/p\u003e\n\u003cp class=\"hvx-v\"\u003eDown to -13°F\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"hvx-desc-card\"\u003e\n\u003ch3 class=\"hvx-section-title\"\u003eWhat’s Included\u003c\/h3\u003e\n\u003cul class=\"hvx-muted\" style=\"margin: 0; padding-left: 18px;\"\u003e\n\u003cli\u003eIndoor 4-way ceiling cassette: CH-RSH48LCCT\u003c\/li\u003e\n\u003cli\u003eOutdoor condenser: CH-R48LCU-230VO\u003c\/li\u003e\n\u003cli\u003eRemote control (indoor control package)\u003c\/li\u003e\n\u003cli\u003eCeiling Cassette Panel\u003c\/li\u003e\n\u003cli\u003eBuilt-in condensate pump with float switch (indoor)\u003c\/li\u003e\n\u003cli\u003eSmart Kit capability for app control (setup required)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"hvx-desc-card\"\u003e\n\u003ch3 class=\"hvx-section-title\"\u003eIndoor Specs (CH-RSH48LCCT)\u003c\/h3\u003e\n\u003cdiv class=\"hvx-table-wrap\"\u003e\n\u003ctable class=\"hvx-table\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eSpec\u003c\/th\u003e\n\u003cth\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRefrigerant Type\u003c\/td\u003e\n\u003ctd\u003eR454B\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSystem Type\u003c\/td\u003e\n\u003ctd\u003eSingle Zone\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBTU Rated\u003c\/td\u003e\n\u003ctd\u003e48,000\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower\u003c\/td\u003e\n\u003ctd\u003e208–230V • 1Ph • 60Hz (Voltage Range: 187–253V)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSEER2 \/ EER2\u003c\/td\u003e\n\u003ctd\u003e18 \/ 10\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDehumidification\u003c\/td\u003e\n\u003ctd\u003e12.96 pints\/day\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIndoor Airflow (CFM)\u003c\/td\u003e\n\u003ctd\u003e1,236.1 \/ 1,124.2 \/ 1,018.3 \/ 800.5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNoise (dB(A))\u003c\/td\u003e\n\u003ctd\u003e52 \/ 49.5 \/ 41.5 (H\/M\/L)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUnit Dimensions (W×D×H)\u003c\/td\u003e\n\u003ctd\u003e32.68 × 32.68 × 11.30 in\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNet \/ Gross Weight\u003c\/td\u003e\n\u003ctd\u003e64.59 \/ 76.06 lb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRefrigerant Piping\u003c\/td\u003e\n\u003ctd\u003e3\/8\" Liquid • 3\/4\" Gas\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDrain Pipe Diameter\u003c\/td\u003e\n\u003ctd\u003e1\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Range\u003c\/td\u003e\n\u003ctd\u003eCooling: 60–90°F • Heating: 32–86°F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMinimum Circuit Ampacity\u003c\/td\u003e\n\u003ctd\u003e3 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax Fuse\u003c\/td\u003e\n\u003ctd\u003e15 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePacking Dimensions (WxDxH)\u003c\/td\u003e\n\u003ctd\u003e35.83 × 35.83 × 12.99 in\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"hvx-desc-card\"\u003e\n\u003ch3 class=\"hvx-section-title\"\u003eOutdoor Specs (CH-R48LCU-230VO)\u003c\/h3\u003e\n\u003cdiv class=\"hvx-table-wrap\"\u003e\n\u003ctable class=\"hvx-table\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eSpec\u003c\/th\u003e\n\u003cth\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRefrigerant Type\u003c\/td\u003e\n\u003ctd\u003eR454B\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBTU Rated\u003c\/td\u003e\n\u003ctd\u003e48,000\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCooling Capacity (Min–Max)\u003c\/td\u003e\n\u003ctd\u003e48,000 (9,500–52,000) BTU\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHeating Capacity (Min–Max)\u003c\/td\u003e\n\u003ctd\u003e50,000 (11,700–60,000) BTU\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHSPF2 (Region IV \/ V)\u003c\/td\u003e\n\u003ctd\u003e10 \/ 7.7\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCOP\u003c\/td\u003e\n\u003ctd\u003e3.5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAHRI\u003c\/td\u003e\n\u003ctd\u003e207742340\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower\u003c\/td\u003e\n\u003ctd\u003e208–230V • 1Ph • 60Hz (Voltage Range: 187–253V)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax Pipe Length\u003c\/td\u003e\n\u003ctd\u003e246 ft\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax Height Difference\u003c\/td\u003e\n\u003ctd\u003e98.4 ft\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMinimum Circuit Ampacity\u003c\/td\u003e\n\u003ctd\u003e39 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax Fuse\u003c\/td\u003e\n\u003ctd\u003e40 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutdoor Airflow\u003c\/td\u003e\n\u003ctd\u003e4,237.9 CFM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutdoor Noise\u003c\/td\u003e\n\u003ctd\u003e65 dB(A)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUnit Dimensions (W×D×H)\u003c\/td\u003e\n\u003ctd\u003e37.48 × 16.34 × 52.48 in\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNet \/ Gross Weight\u003c\/td\u003e\n\u003ctd\u003e208.78 \/ 239.86 lb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAmbient Temperature\u003c\/td\u003e\n\u003ctd\u003eCooling: -13–122°F • Heating: -13–75°F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAdditional Charge\u003c\/td\u003e\n\u003ctd\u003e0.32 oz\/ft (3\/8\" liquid line)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"hvx-desc-card\"\u003e\n\u003ch3 class=\"hvx-section-title\"\u003eDocuments \u0026amp; Downloads\u003c\/h3\u003e\n\u003cul class=\"hvx-muted\" style=\"margin: 0; padding-left: 18px;\"\u003e\n\u003cli\u003e\u003ca class=\"hvx-link\" href=\"https:\/\/media.cooperandhunter.us\/4692\/CH-R48LCU-230VO_CH-RSH48LCCT.pdf\"\u003eSubmittal Sheet: CH-R48LCU-230VO + CH-RSH48LCCT\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca class=\"hvx-link\" href=\"https:\/\/media.cooperandhunter.us\/4696\/CH-RHP48LCU-230VO_CH-RSH48LCCT.pdf\"\u003eSubmittal Sheet: CH-RHP48LCU-230VO + CH-RSH48LCCT\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca class=\"hvx-link\" href=\"https:\/\/media.cooperandhunter.us\/4214\/CH-R48LCU-230VO-%2B-CH-RS48LCDT-HS.pdf\"\u003eSubmittal Sheet: CH-R48LCU-230VO + CH-RS48LCDT-HS\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca class=\"hvx-link\" href=\"https:\/\/media.cooperandhunter.us\/4621\/CH-R48LCU-230VO-%2B-CH-RS48LCAHU.pdf\"\u003eSubmittal Sheet: CH-R48LCU-230VO + CH-RS48LCAHU\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca class=\"hvx-link\" href=\"https:\/\/media.cooperandhunter.us\/4628\/CH-R48LCU-230VO_CH-RSH48LCFC.pdf\"\u003eSubmittal Sheet: CH-R48LCU-230VO + CH-RSH48LCFC\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca class=\"hvx-link\" href=\"https:\/\/media.cooperandhunter.us\/4691\/CH-R48LCU-230VO_CH-RH48LCCT.pdf\"\u003eSubmittal Sheet: CH-R48LCU-230VO + CH-RH48LCCT\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca class=\"hvx-link\" href=\"https:\/\/media.cooperandhunter.us\/4200\/SlimDuct-Leaflet-R454B.pdf\"\u003eSlimDuct Leaflet (R454B)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca class=\"hvx-link\" href=\"https:\/\/media.cooperandhunter.us\/4654\/Installation-manual-R454B-Ceiling-cassette_compressed.pdf\"\u003eCeiling Cassette Installation Manual (R454B)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca class=\"hvx-link\" href=\"https:\/\/media.cooperandhunter.us\/4655\/Owners_-manual-R454B-Ceiling-cassette_compressed.pdf\"\u003eCeiling Cassette Owner’s Manual (R454B)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca class=\"hvx-link\" href=\"https:\/\/media.cooperandhunter.us\/3309\/120N--uses-and-installation-manual.pdf\"\u003e120N Wire Controller — Uses \u0026amp; Installation Manual\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca class=\"hvx-link\" href=\"https:\/\/media.cooperandhunter.us\/3198\/MultiZone-Combination-HYPER.pdf\"\u003eMultiZone Combination Guide — Hyper\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca class=\"hvx-link\" href=\"https:\/\/media.cooperandhunter.us\/3199\/MultiZone-Combination-Regular.pdf\"\u003eMultiZone Combination Guide — Regular\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"hvx-desc-card\"\u003e\n\u003ch3 class=\"hvx-section-title\"\u003eImportant\u003c\/h3\u003e\n\u003cul class=\"hvx-muted\" style=\"margin: 0; padding-left: 18px;\"\u003e\n\u003cli\u003eProfessional installation is recommended.\u003c\/li\u003e\n\u003cli\u003eMatch line set sizes to the equipment: 3\/8\" liquid and 3\/4\" suction.\u003c\/li\u003e\n\u003cli\u003eVerify the dedicated circuit is sized per equipment MCA and local code.\u003c\/li\u003e\n\u003cli\u003eNeed help choosing equipment? \u003ca class=\"hvx-link\" href=\"https:\/\/hvacsupplies.com\/pages\/contact\"\u003ehvacsupplies.com\/pages\/contact\u003c\/a\u003e • \u003ca class=\"hvx-link\" href=\"tel:+18005438933\"\u003e(800) 543-8933\u003c\/a\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"hvx-desc-card hvx-faq\"\u003e\n\u003ch3 class=\"hvx-section-title\"\u003eFAQs\u003c\/h3\u003e\n\u003cdetails\u003e\n\u003csummary\u003eDoes the cassette include a condensate pump?\u003c\/summary\u003e\n\u003cp class=\"hvx-muted\"\u003eYes. CH-RSH48LCCT includes a built-in pump with float switch (20.9\" lift).\u003c\/p\u003e\n\u003c\/details\u003e\n\u003cdetails\u003e\n\u003csummary\u003eWhat line set sizes are required?\u003c\/summary\u003e\n\u003cp class=\"hvx-muted\"\u003e3\/8\" liquid line and 3\/4\" suction (gas) line.\u003c\/p\u003e\n\u003c\/details\u003e\n\u003cdetails\u003e\n\u003csummary\u003eHow cold can the outdoor unit operate in heating?\u003c\/summary\u003e\n\u003cp class=\"hvx-muted\"\u003eCH-R48LCU-230VO supports heating operation down to -13°F ambient.\u003c\/p\u003e\n\u003c\/details\u003e\n\u003cdetails\u003e\n\u003csummary\u003eCan I control the system with an app?\u003c\/summary\u003e\n\u003cp class=\"hvx-muted\"\u003eSmart Kit capability supports app control through the C\u0026amp;H platform after setup.\u003c\/p\u003e\n\u003c\/details\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e","brand":"Cooper\u0026Hunter","offers":[{"title":"No Installation","offer_id":42691124461611,"sku":"CH-RSH48LCCT + CH-R48LCU-230VO","price":4144.0,"currency_code":"USD","in_stock":true},{"title":"25FT","offer_id":42691124494379,"sku":"CH-RSH48LCCT + CH-R48LCU-230VO","price":4625.0,"currency_code":"USD","in_stock":true},{"title":"50FT","offer_id":42691124527147,"sku":"CH-RSH48LCCT + CH-R48LCU-230VO","price":4818.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0625\/5647\/1339\/files\/2-ZoneDuctlessMiniSplitAC_HeatPump48000BTU_24_9395a77f-4b00-4fa2-bbdb-9a6d5254a8df.png?v=1770423591"},{"product_id":"cooper-hunter-48-000-btu-hyper-single-zone-four-way-ceiling-cassette-w-humidity-sensor-minisplit-heat-pump-system-r454b-230v","title":"Cooper\u0026Hunter 48,000 BTU Hyper Single Zone Four-Way Ceiling Cassette w\/ Humidity Sensor Minisplit Heat Pump System R454B 230V","description":"\u003cstyle\u003e\n    :root{--hvx-golden:#FAA819;--hvx-slate:#262626;--hvx-ivory:#F4F1E6;--hvx-border:#e2e0d5;--hvx-card-bg:#ffffff;}\n    .hvx-desc{background:var(--hvx-ivory);padding:18px;border-radius:18px;font-family:\"Articulat CF\",system-ui,-apple-system,Segoe UI,Roboto,Arial,sans-serif;color:#111;}\n    .hvx-desc-header{background:linear-gradient(120deg,var(--hvx-golden),var(--hvx-slate));border-radius:16px;padding:16px 16px 14px;color:#fff;margin-bottom:14px;}\n    .hvx-eyebrow{font-size:12px;letter-spacing:.12em;text-transform:uppercase;opacity:.9;margin:0 0 6px;}\n    .hvx-title{font-family:\"Anton\",Impact,Haettenschweiler,\"Arial Narrow Bold\",sans-serif;font-size:26px;line-height:1.05;margin:0;}\n    .hvx-desc-card{background:var(--hvx-card-bg);border:1px solid var(--hvx-border);border-radius:16px;padding:14px;margin:12px 0;box-shadow:0 10px 18px rgba(0,0,0,.06);}\n    .hvx-section-title{margin:0 0 10px;font-size:13px;letter-spacing:.12em;text-transform:uppercase;display:inline-block;padding-bottom:6px;position:relative;}\n    .hvx-section-title:after{content:\"\";position:absolute;left:0;bottom:0;height:3px;width:100%;border-radius:99px;background:linear-gradient(90deg,var(--hvx-golden),var(--hvx-slate));}\n    .hvx-badges{display:flex;flex-wrap:wrap;gap:8px;margin:6px 0 10px;}\n    .hvx-badge{display:inline-flex;align-items:center;gap:6px;padding:6px 10px;border-radius:999px;border:1px solid var(--hvx-border);background:#fff;font-size:12px;font-weight:600;}\n    .hvx-grid{display:grid;grid-template-columns:repeat(3,minmax(0,1fr));gap:10px;}\n    .hvx-kv{border:1px solid var(--hvx-border);border-radius:14px;padding:10px;background:#fff;}\n    .hvx-k{font-size:12px;letter-spacing:.08em;text-transform:uppercase;color:#333;margin:0 0 6px;}\n    .hvx-v{font-size:14px;font-weight:700;margin:0;}\n    .hvx-table-wrap{overflow:auto;border-radius:14px;border:1px solid var(--hvx-border);background:#fff;}\n    table.hvx-table{width:100%;border-collapse:collapse;min-width:520px;}\n    .hvx-table th,.hvx-table td{padding:10px 12px;border-bottom:1px solid var(--hvx-border);vertical-align:top;font-size:14px;}\n    .hvx-table th{background:rgba(250,168,25,.12);text-align:left;font-size:12px;letter-spacing:.1em;text-transform:uppercase;}\n    .hvx-table tr:last-child td{border-bottom:none;}\n    .hvx-link{color:#111;text-decoration:none;border-bottom:2px solid rgba(250,168,25,.7);}\n    .hvx-link:hover{border-bottom-color:#111;}\n    .hvx-faq details{border:1px solid var(--hvx-border);border-radius:14px;background:#fff;padding:10px 12px;margin:10px 0;}\n    .hvx-faq summary{cursor:pointer;font-weight:800;}\n    .hvx-muted{color:#333;margin:6px 0 0;}\n    @media (max-width:720px){.hvx-grid{grid-template-columns:1fr;}.hvx-title{font-size:24px;}}\n  \u003c\/style\u003e\n\u003cdiv class=\"hvx-desc\"\u003e\n\u003cdiv class=\"hvx-desc-header\"\u003e\n\u003cp class=\"hvx-eyebrow\"\u003eSingle Zone • 48,000 BTU • 4-Way Ceiling Cassette • R454B • 208–230V\u003c\/p\u003e\n\u003ch2 class=\"hvx-title\"\u003eCooper\u0026amp;Hunter 48,000 BTU Hyper Single Zone Four-Way Ceiling Cassette w\/ Humidity Sensor Minisplit Heat Pump System R454B 230V\u003c\/h2\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"hvx-desc-card\"\u003e\n\u003ch3 class=\"hvx-section-title\"\u003eOverview\u003c\/h3\u003e\n\u003cp class=\"hvx-muted\"\u003e48K 4-way ceiling cassette pairing designed for even distribution across large areas using a 360° airflow panel. Includes a built-in condensate pump and comfort modes like turbo and sleep. Pairing with the Hyper outdoor unit supports low-ambient heating capability for demanding climates.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"hvx-desc-card\"\u003e\n\u003ch3 class=\"hvx-section-title\"\u003eHighlights\u003c\/h3\u003e\n\u003cdiv class=\"hvx-badges\"\u003e\n\u003cspan class=\"hvx-badge\"\u003eR454B Refrigerant\u003c\/span\u003e \u003cspan class=\"hvx-badge\"\u003e360° Airflow Panel\u003c\/span\u003e \u003cspan class=\"hvx-badge\"\u003eHumidity Sensor\u003c\/span\u003e \u003cspan class=\"hvx-badge\"\u003eGoldFin Coating\u003c\/span\u003e \u003cspan class=\"hvx-badge\"\u003eBuilt-In Pump\u003c\/span\u003e \u003cspan class=\"hvx-badge\"\u003eHyper Heating Outdoor\u003c\/span\u003e\n\u003c\/div\u003e\n\u003cul style=\"margin: 0 0 10px; padding-left: 18px;\" class=\"hvx-muted\"\u003e\n\u003cli\u003e360° panel and omni-directional airflow help cover large rooms evenly.\u003c\/li\u003e\n\u003cli\u003eActivated carbon filtration support for fresher indoor air.\u003c\/li\u003e\n\u003cli\u003eAnti-cold-air heating behavior reduces drafts during heat mode.\u003c\/li\u003e\n\u003cli\u003eBuilt-in pump with float switch (20.9\" lift) for quiet condensate removal.\u003c\/li\u003e\n\u003cli\u003eMultiple fan speeds plus turbo and sleep modes for comfort control.\u003c\/li\u003e\n\u003cli\u003eHyper outdoor supports heating operation down to -22°F ambient.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cdiv class=\"hvx-grid\"\u003e\n\u003cdiv class=\"hvx-kv\"\u003e\n\u003cp class=\"hvx-k\"\u003eIndoor Model\u003c\/p\u003e\n\u003cp class=\"hvx-v\"\u003e\u003ca href=\"https:\/\/hvacsupplies.com\/search?options%5Bprefix%5D=last\u0026amp;q=CH-RH48LCCT\" class=\"hvx-link\"\u003eCH-RH48LCCT\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"hvx-kv\"\u003e\n\u003cp class=\"hvx-k\"\u003eOutdoor Model\u003c\/p\u003e\n\u003cp class=\"hvx-v\"\u003e\u003ca href=\"https:\/\/hvacsupplies.com\/search?options%5Bprefix%5D=last\u0026amp;q=CH-RHP48LCU-230VO\" class=\"hvx-link\"\u003eCH-RHP48LCU-230VO\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"hvx-kv\"\u003e\n\u003cp class=\"hvx-k\"\u003eLine Set Size\u003c\/p\u003e\n\u003cp class=\"hvx-v\"\u003e3\/8\" Liquid • 3\/4\" Gas\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"hvx-kv\"\u003e\n\u003cp class=\"hvx-k\"\u003ePower\u003c\/p\u003e\n\u003cp class=\"hvx-v\"\u003e208–230V • 1Ph • 60Hz\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"hvx-kv\"\u003e\n\u003cp class=\"hvx-k\"\u003eMax Line Length\u003c\/p\u003e\n\u003cp class=\"hvx-v\"\u003e246 ft\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"hvx-kv\"\u003e\n\u003cp class=\"hvx-k\"\u003eLow-Ambient Heating\u003c\/p\u003e\n\u003cp class=\"hvx-v\"\u003eDown to -22°F\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"hvx-desc-card\"\u003e\n\u003ch3 class=\"hvx-section-title\"\u003eWhat’s Included\u003c\/h3\u003e\n\u003cul style=\"margin: 0; padding-left: 18px;\" class=\"hvx-muted\"\u003e\n\u003cli\u003eIndoor 4-way ceiling cassette: CH-RH48LCCT\u003c\/li\u003e\n\u003cli\u003eOutdoor condenser: CH-RHP48LCU-230VO (Hyper)\u003c\/li\u003e\n\u003cli\u003eRemote control (indoor control package)\u003c\/li\u003e\n\u003cli\u003eCeiling Cassette Panel\u003c\/li\u003e\n\u003cli\u003eBuilt-in condensate pump with float switch (indoor)\u003c\/li\u003e\n\u003cli\u003eSmart Kit capability for app control (setup required)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"hvx-desc-card\"\u003e\n\u003ch3 class=\"hvx-section-title\"\u003eIndoor Specs (CH-RH48LCCT)\u003c\/h3\u003e\n\u003cdiv class=\"hvx-table-wrap\"\u003e\n\u003ctable class=\"hvx-table\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eSpec\u003c\/th\u003e\n\u003cth\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRefrigerant Type\u003c\/td\u003e\n\u003ctd\u003eR454B\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSystem Type\u003c\/td\u003e\n\u003ctd\u003eSingle Zone\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBTU Rated\u003c\/td\u003e\n\u003ctd\u003e48,000\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower\u003c\/td\u003e\n\u003ctd\u003e208–230V • 1Ph • 60Hz (Voltage Range: 187–253V)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSEER2 \/ EER2\u003c\/td\u003e\n\u003ctd\u003e18 \/ 10\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDehumidification\u003c\/td\u003e\n\u003ctd\u003e12.96 pints\/day\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIndoor Airflow (CFM)\u003c\/td\u003e\n\u003ctd\u003e1,236.1 \/ 1,124.2 \/ 1,018.3 \/ 800.5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNoise (dB(A))\u003c\/td\u003e\n\u003ctd\u003e52 \/ 49.5 \/ 41.5 (H\/M\/L)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUnit Dimensions (W×D×H)\u003c\/td\u003e\n\u003ctd\u003e32.68 × 32.68 × 11.30 in\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNet \/ Gross Weight\u003c\/td\u003e\n\u003ctd\u003e64.59 \/ 76.06 lb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRefrigerant Piping\u003c\/td\u003e\n\u003ctd\u003e3\/8\" Liquid • 3\/4\" Gas\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDrain Pipe Diameter\u003c\/td\u003e\n\u003ctd\u003e1\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Range\u003c\/td\u003e\n\u003ctd\u003eCooling: 60–90°F • Heating: 32–86°F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMinimum Circuit Ampacity\u003c\/td\u003e\n\u003ctd\u003e3 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax Fuse\u003c\/td\u003e\n\u003ctd\u003e15 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePacking Dimensions (WxDxH)\u003c\/td\u003e\n\u003ctd\u003e35.83 × 35.83 × 12.99 in\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"hvx-desc-card\"\u003e\n\u003ch3 class=\"hvx-section-title\"\u003eOutdoor Specs (CH-RHP48LCU-230VO)\u003c\/h3\u003e\n\u003cdiv class=\"hvx-table-wrap\"\u003e\n\u003ctable class=\"hvx-table\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eSpec\u003c\/th\u003e\n\u003cth\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRefrigerant Type\u003c\/td\u003e\n\u003ctd\u003eR454B\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSystem Type\u003c\/td\u003e\n\u003ctd\u003eSingle-zone unit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBTU Rated\u003c\/td\u003e\n\u003ctd\u003e48,000\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCooling Capacity (Min–Max)\u003c\/td\u003e\n\u003ctd\u003e48,000 (11,000–56,500) BTU\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHeating Capacity (Min–Max)\u003c\/td\u003e\n\u003ctd\u003e52,000 (11,200–60,000) BTU\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSEER2 \/ EER2\u003c\/td\u003e\n\u003ctd\u003e16.7 \/ 10.4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHSPF2 (Region IV \/ V)\u003c\/td\u003e\n\u003ctd\u003e10.8 \/ 8.8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCOP\u003c\/td\u003e\n\u003ctd\u003e3.6\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower\u003c\/td\u003e\n\u003ctd\u003e208–230V • 1Ph • 60Hz (Voltage Range: 187–253V)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax Pipe Length\u003c\/td\u003e\n\u003ctd\u003e246 ft\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax Height Difference\u003c\/td\u003e\n\u003ctd\u003e98.4 ft\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMinimum Circuit Ampacity\u003c\/td\u003e\n\u003ctd\u003e44 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax Fuse\u003c\/td\u003e\n\u003ctd\u003e45 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutdoor Airflow\u003c\/td\u003e\n\u003ctd\u003e4,237.9 CFM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutdoor Noise\u003c\/td\u003e\n\u003ctd\u003e65 dB(A)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUnit Dimensions (W×D×H)\u003c\/td\u003e\n\u003ctd\u003e37.48 × 16.34 × 52.48 in\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNet \/ Gross Weight\u003c\/td\u003e\n\u003ctd\u003e208.78 \/ 239.86 lb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAmbient Temperature\u003c\/td\u003e\n\u003ctd\u003eCooling: -22–122°F • Heating: -22–75°F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAdditional Charge\u003c\/td\u003e\n\u003ctd\u003e0.32 oz\/ft (3\/8\" liquid line)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"hvx-desc-card\"\u003e\n\u003ch3 class=\"hvx-section-title\"\u003eDocuments \u0026amp; Downloads\u003c\/h3\u003e\n\u003cul style=\"margin: 0; padding-left: 18px;\" class=\"hvx-muted\"\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/media.cooperandhunter.us\/4695\/CH-RHP48LCU-230VO_CH-RH48LCCT.pdf\" class=\"hvx-link\"\u003eSubmittal Sheet: CH-RHP48LCU-230VO + CH-RH48LCCT\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/media.cooperandhunter.us\/4691\/CH-R48LCU-230VO_CH-RH48LCCT.pdf\" class=\"hvx-link\"\u003eSubmittal Sheet: CH-R48LCU-230VO + CH-RH48LCCT\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/media.cooperandhunter.us\/4207\/CH-RHP48LCU-230VO-%2B-CH-RS48LCDT-HS.pdf\" class=\"hvx-link\"\u003eSubmittal Sheet: CH-RHP48LCU-230VO + CH-RS48LCDT-HS\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/media.cooperandhunter.us\/4633\/CH-RHP48LCU-230VO_CH-RSH48LCFC.pdf\" class=\"hvx-link\"\u003eSubmittal Sheet: CH-RHP48LCU-230VO + CH-RSH48LCFC\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/media.cooperandhunter.us\/4696\/CH-RHP48LCU-230VO_CH-RSH48LCCT.pdf\" class=\"hvx-link\"\u003eSubmittal Sheet: CH-RHP48LCU-230VO + CH-RSH48LCCT\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/media.cooperandhunter.us\/4200\/SlimDuct-Leaflet-R454B.pdf\" class=\"hvx-link\"\u003eSlimDuct Leaflet (R454B)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/media.cooperandhunter.us\/4654\/Installation-manual-R454B-Ceiling-cassette_compressed.pdf\" class=\"hvx-link\"\u003eCeiling Cassette Installation Manual (R454B)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/media.cooperandhunter.us\/4655\/Owners_-manual-R454B-Ceiling-cassette_compressed.pdf\" class=\"hvx-link\"\u003eCeiling Cassette Owner’s Manual (R454B)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/media.cooperandhunter.us\/3309\/120N--uses-and-installation-manual.pdf\" class=\"hvx-link\"\u003e120N Wire Controller — Uses \u0026amp; Installation Manual\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/media.cooperandhunter.us\/3198\/MultiZone-Combination-HYPER.pdf\" class=\"hvx-link\"\u003eMultiZone Combination Guide — Hyper\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/media.cooperandhunter.us\/3199\/MultiZone-Combination-Regular.pdf\" class=\"hvx-link\"\u003eMultiZone Combination Guide — Regular\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"hvx-desc-card\"\u003e\n\u003ch3 class=\"hvx-section-title\"\u003eImportant\u003c\/h3\u003e\n\u003cul style=\"margin: 0; padding-left: 18px;\" class=\"hvx-muted\"\u003e\n\u003cli\u003eProfessional installation is recommended.\u003c\/li\u003e\n\u003cli\u003eMatch line set sizes to the equipment: 3\/8\" liquid and 3\/4\" suction.\u003c\/li\u003e\n\u003cli\u003eVerify the dedicated circuit is sized per equipment MCA and local code.\u003c\/li\u003e\n\u003cli\u003eNeed help choosing equipment? \u003ca href=\"https:\/\/hvacsupplies.com\/pages\/contact\" class=\"hvx-link\"\u003ehvacsupplies.com\/pages\/contact\u003c\/a\u003e • \u003ca href=\"tel:+18005438933\" class=\"hvx-link\"\u003e(800) 543-8933\u003c\/a\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"hvx-desc-card hvx-faq\"\u003e\n\u003ch3 class=\"hvx-section-title\"\u003eFAQs\u003c\/h3\u003e\n\u003cdetails\u003e\n\u003csummary\u003eDoes the cassette include a condensate pump?\u003c\/summary\u003e\n\u003cp class=\"hvx-muted\"\u003eYes. CH-RH48LCCT includes a built-in pump with float switch (20.9\" lift).\u003c\/p\u003e\n\u003c\/details\u003e\n\u003cdetails\u003e\n\u003csummary\u003eWhat line set sizes are required?\u003c\/summary\u003e\n\u003cp class=\"hvx-muted\"\u003e3\/8\" liquid line and 3\/4\" suction (gas) line.\u003c\/p\u003e\n\u003c\/details\u003e\n\u003cdetails\u003e\n\u003csummary\u003eHow cold can the Hyper outdoor unit heat?\u003c\/summary\u003e\n\u003cp class=\"hvx-muted\"\u003eCH-RHP48LCU-230VO supports heating operation down to -22°F ambient.\u003c\/p\u003e\n\u003c\/details\u003e\n\u003cdetails\u003e\n\u003csummary\u003eCan I control the system with an app?\u003c\/summary\u003e\n\u003cp class=\"hvx-muted\"\u003eSmart Kit capability supports app control through the C\u0026amp;H platform after setup.\u003c\/p\u003e\n\u003c\/details\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e","brand":"Cooper\u0026Hunter","offers":[{"title":"No Installation","offer_id":42691124854827,"sku":"CH-RH48LCCT + CH-RHP48LCU-230VO","price":5273.0,"currency_code":"USD","in_stock":true},{"title":"25FT","offer_id":42691124887595,"sku":"CH-RH48LCCT + CH-RHP48LCU-230VO","price":5754.0,"currency_code":"USD","in_stock":true},{"title":"50FT","offer_id":42691124920363,"sku":"CH-RH48LCCT + CH-RHP48LCU-230VO","price":5947.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0625\/5647\/1339\/files\/2-ZoneDuctlessMiniSplitAC_HeatPump48000BTU_25.png?v=1769198682"},{"product_id":"cooper-hunter-48-000-btu-single-zone-four-way-ceiling-cassette-w-humidity-sensor-minisplit-heat-pump-system-r454b-230v","title":"Cooper\u0026Hunter 48,000 BTU Single Zone Four-Way Ceiling Cassette w\/ Humidity Sensor Minisplit Heat Pump System R454B 230V","description":"\u003cstyle\u003e\n    :root{--hvx-golden:#FAA819;--hvx-slate:#262626;--hvx-ivory:#F4F1E6;--hvx-border:#e2e0d5;--hvx-card-bg:#ffffff;}\n    .hvx-desc{background:var(--hvx-ivory);padding:18px;border-radius:18px;font-family:\"Articulat CF\",system-ui,-apple-system,Segoe UI,Roboto,Arial,sans-serif;color:#111;}\n    .hvx-desc-header{background:linear-gradient(120deg,var(--hvx-golden),var(--hvx-slate));border-radius:16px;padding:16px 16px 14px;color:#fff;margin-bottom:14px;}\n    .hvx-eyebrow{font-size:12px;letter-spacing:.12em;text-transform:uppercase;opacity:.9;margin:0 0 6px;}\n    .hvx-title{font-family:\"Anton\",Impact,Haettenschweiler,\"Arial Narrow Bold\",sans-serif;font-size:26px;line-height:1.05;margin:0;}\n    .hvx-desc-card{background:var(--hvx-card-bg);border:1px solid var(--hvx-border);border-radius:16px;padding:14px;margin:12px 0;box-shadow:0 10px 18px rgba(0,0,0,.06);}\n    .hvx-section-title{margin:0 0 10px;font-size:13px;letter-spacing:.12em;text-transform:uppercase;display:inline-block;padding-bottom:6px;position:relative;}\n    .hvx-section-title:after{content:\"\";position:absolute;left:0;bottom:0;height:3px;width:100%;border-radius:99px;background:linear-gradient(90deg,var(--hvx-golden),var(--hvx-slate));}\n    .hvx-badges{display:flex;flex-wrap:wrap;gap:8px;margin:6px 0 10px;}\n    .hvx-badge{display:inline-flex;align-items:center;gap:6px;padding:6px 10px;border-radius:999px;border:1px solid var(--hvx-border);background:#fff;font-size:12px;font-weight:600;}\n    .hvx-grid{display:grid;grid-template-columns:repeat(3,minmax(0,1fr));gap:10px;}\n    .hvx-kv{border:1px solid var(--hvx-border);border-radius:14px;padding:10px;background:#fff;}\n    .hvx-k{font-size:12px;letter-spacing:.08em;text-transform:uppercase;color:#333;margin:0 0 6px;}\n    .hvx-v{font-size:14px;font-weight:700;margin:0;}\n    .hvx-table-wrap{overflow:auto;border-radius:14px;border:1px solid var(--hvx-border);background:#fff;}\n    table.hvx-table{width:100%;border-collapse:collapse;min-width:520px;}\n    .hvx-table th,.hvx-table td{padding:10px 12px;border-bottom:1px solid var(--hvx-border);vertical-align:top;font-size:14px;}\n    .hvx-table th{background:rgba(250,168,25,.12);text-align:left;font-size:12px;letter-spacing:.1em;text-transform:uppercase;}\n    .hvx-table tr:last-child td{border-bottom:none;}\n    .hvx-link{color:#111;text-decoration:none;border-bottom:2px solid rgba(250,168,25,.7);}\n    .hvx-link:hover{border-bottom-color:#111;}\n    .hvx-faq details{border:1px solid var(--hvx-border);border-radius:14px;background:#fff;padding:10px 12px;margin:10px 0;}\n    .hvx-faq summary{cursor:pointer;font-weight:800;}\n    .hvx-muted{color:#333;margin:6px 0 0;}\n    @media (max-width:720px){.hvx-grid{grid-template-columns:1fr;}.hvx-title{font-size:24px;}}\n  \u003c\/style\u003e\n\u003cdiv class=\"hvx-desc\"\u003e\n\u003cdiv class=\"hvx-desc-header\"\u003e\n\u003cp class=\"hvx-eyebrow\"\u003eSingle Zone • 48,000 BTU • 4-Way Ceiling Cassette • R454B • 208–230V\u003c\/p\u003e\n\u003ch2 class=\"hvx-title\"\u003eCooper\u0026amp;Hunter 48,000 BTU Single Zone Four-Way Ceiling Cassette w\/ Humidity Sensor Minisplit Heat Pump System R454B 230V\u003c\/h2\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"hvx-desc-card\"\u003e\n\u003ch3 class=\"hvx-section-title\"\u003eOverview\u003c\/h3\u003e\n\u003cp class=\"hvx-muted\"\u003e48K 4-way ceiling cassette pairing designed for even distribution across large areas using a 360° airflow panel. Includes a built-in condensate pump and comfort modes like turbo and sleep. Pair with CH-R48LCU-230VO for efficient inverter performance and broad operating range.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"hvx-desc-card\"\u003e\n\u003ch3 class=\"hvx-section-title\"\u003eHighlights\u003c\/h3\u003e\n\u003cdiv class=\"hvx-badges\"\u003e\n\u003cspan class=\"hvx-badge\"\u003eR454B Refrigerant\u003c\/span\u003e \u003cspan class=\"hvx-badge\"\u003e360° Airflow Panel\u003c\/span\u003e \u003cspan class=\"hvx-badge\"\u003eHumidity Sensor\u003c\/span\u003e \u003cspan class=\"hvx-badge\"\u003eGoldFin Coating\u003c\/span\u003e \u003cspan class=\"hvx-badge\"\u003eBuilt-In Pump\u003c\/span\u003e \u003cspan class=\"hvx-badge\"\u003eInverter Outdoor\u003c\/span\u003e\n\u003c\/div\u003e\n\u003cul style=\"margin: 0 0 10px; padding-left: 18px;\" class=\"hvx-muted\"\u003e\n\u003cli\u003e360° panel and omni-directional airflow help cover large rooms evenly.\u003c\/li\u003e\n\u003cli\u003eActivated carbon filtration support for fresher indoor air.\u003c\/li\u003e\n\u003cli\u003eAnti-cold-air heating behavior reduces drafts during heat mode.\u003c\/li\u003e\n\u003cli\u003eBuilt-in pump with float switch (20.9\" lift) for quiet condensate removal.\u003c\/li\u003e\n\u003cli\u003eMultiple fan speeds plus turbo and sleep modes for comfort control.\u003c\/li\u003e\n\u003cli\u003eOutdoor heating operation supports down to -13°F ambient.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cdiv class=\"hvx-grid\"\u003e\n\u003cdiv class=\"hvx-kv\"\u003e\n\u003cp class=\"hvx-k\"\u003eIndoor Model\u003c\/p\u003e\n\u003cp class=\"hvx-v\"\u003e\u003ca href=\"https:\/\/hvacsupplies.com\/search?options%5Bprefix%5D=last\u0026amp;q=CH-RH48LCCT\" class=\"hvx-link\"\u003eCH-RH48LCCT\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"hvx-kv\"\u003e\n\u003cp class=\"hvx-k\"\u003eOutdoor Model\u003c\/p\u003e\n\u003cp class=\"hvx-v\"\u003e\u003ca href=\"https:\/\/hvacsupplies.com\/search?options%5Bprefix%5D=last\u0026amp;q=CH-R48LCU-230VO\" class=\"hvx-link\"\u003eCH-R48LCU-230VO\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"hvx-kv\"\u003e\n\u003cp class=\"hvx-k\"\u003eLine Set Size\u003c\/p\u003e\n\u003cp class=\"hvx-v\"\u003e3\/8\" Liquid • 3\/4\" Gas\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"hvx-kv\"\u003e\n\u003cp class=\"hvx-k\"\u003ePower\u003c\/p\u003e\n\u003cp class=\"hvx-v\"\u003e208–230V • 1Ph • 60Hz\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"hvx-kv\"\u003e\n\u003cp class=\"hvx-k\"\u003eMax Line Length\u003c\/p\u003e\n\u003cp class=\"hvx-v\"\u003e246 ft\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"hvx-kv\"\u003e\n\u003cp class=\"hvx-k\"\u003eLow-Ambient Heating\u003c\/p\u003e\n\u003cp class=\"hvx-v\"\u003eDown to -13°F\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"hvx-desc-card\"\u003e\n\u003ch3 class=\"hvx-section-title\"\u003eWhat’s Included\u003c\/h3\u003e\n\u003cul style=\"margin: 0; padding-left: 18px;\" class=\"hvx-muted\"\u003e\n\u003cli\u003eIndoor 4-way ceiling cassette: CH-RH48LCCT\u003c\/li\u003e\n\u003cli\u003eOutdoor condenser: CH-R48LCU-230VO\u003c\/li\u003e\n\u003cli\u003eRemote control (indoor control package)\u003c\/li\u003e\n\u003cli\u003eCeiling Cassette Panel\u003c\/li\u003e\n\u003cli\u003eBuilt-in condensate pump with float switch (indoor)\u003c\/li\u003e\n\u003cli\u003eSmart Kit capability for app control (setup required)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"hvx-desc-card\"\u003e\n\u003ch3 class=\"hvx-section-title\"\u003eIndoor Specs (CH-RH48LCCT)\u003c\/h3\u003e\n\u003cdiv class=\"hvx-table-wrap\"\u003e\n\u003ctable class=\"hvx-table\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eSpec\u003c\/th\u003e\n\u003cth\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRefrigerant Type\u003c\/td\u003e\n\u003ctd\u003eR454B\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSystem Type\u003c\/td\u003e\n\u003ctd\u003eSingle Zone\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBTU Rated\u003c\/td\u003e\n\u003ctd\u003e48,000\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower\u003c\/td\u003e\n\u003ctd\u003e208–230V • 1Ph • 60Hz (Voltage Range: 187–253V)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSEER2 \/ EER2\u003c\/td\u003e\n\u003ctd\u003e18 \/ 10\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDehumidification\u003c\/td\u003e\n\u003ctd\u003e12.96 pints\/day\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIndoor Airflow (CFM)\u003c\/td\u003e\n\u003ctd\u003e1,236.1 \/ 1,124.2 \/ 1,018.3 \/ 800.5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNoise (dB(A))\u003c\/td\u003e\n\u003ctd\u003e52 \/ 49.5 \/ 41.5 (H\/M\/L)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUnit Dimensions (W×D×H)\u003c\/td\u003e\n\u003ctd\u003e32.68 × 32.68 × 11.30 in\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNet \/ Gross Weight\u003c\/td\u003e\n\u003ctd\u003e64.59 \/ 76.06 lb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRefrigerant Piping\u003c\/td\u003e\n\u003ctd\u003e3\/8\" Liquid • 3\/4\" Gas\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDrain Pipe Diameter\u003c\/td\u003e\n\u003ctd\u003e1\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Range\u003c\/td\u003e\n\u003ctd\u003eCooling: 60–90°F • Heating: 32–86°F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMinimum Circuit Ampacity\u003c\/td\u003e\n\u003ctd\u003e3 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax Fuse\u003c\/td\u003e\n\u003ctd\u003e15 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePacking Dimensions (WxDxH)\u003c\/td\u003e\n\u003ctd\u003e35.83 × 35.83 × 12.99 in\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"hvx-desc-card\"\u003e\n\u003ch3 class=\"hvx-section-title\"\u003eOutdoor Specs (CH-R48LCU-230VO)\u003c\/h3\u003e\n\u003cdiv class=\"hvx-table-wrap\"\u003e\n\u003ctable class=\"hvx-table\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eSpec\u003c\/th\u003e\n\u003cth\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRefrigerant Type\u003c\/td\u003e\n\u003ctd\u003eR454B\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBTU Rated\u003c\/td\u003e\n\u003ctd\u003e48,000\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCooling Capacity (Min–Max)\u003c\/td\u003e\n\u003ctd\u003e48,000 (9,500–52,000) BTU\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHeating Capacity (Min–Max)\u003c\/td\u003e\n\u003ctd\u003e50,000 (11,700–60,000) BTU\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHSPF2 (Region IV \/ V)\u003c\/td\u003e\n\u003ctd\u003e10 \/ 7.7\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCOP\u003c\/td\u003e\n\u003ctd\u003e3.5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAHRI\u003c\/td\u003e\n\u003ctd\u003e207742340\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower\u003c\/td\u003e\n\u003ctd\u003e208–230V • 1Ph • 60Hz (Voltage Range: 187–253V)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax Pipe Length\u003c\/td\u003e\n\u003ctd\u003e246 ft\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax Height Difference\u003c\/td\u003e\n\u003ctd\u003e98.4 ft\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMinimum Circuit Ampacity\u003c\/td\u003e\n\u003ctd\u003e39 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax Fuse\u003c\/td\u003e\n\u003ctd\u003e40 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutdoor Airflow\u003c\/td\u003e\n\u003ctd\u003e4,237.9 CFM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutdoor Noise\u003c\/td\u003e\n\u003ctd\u003e65 dB(A)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUnit Dimensions (W×D×H)\u003c\/td\u003e\n\u003ctd\u003e37.48 × 16.34 × 52.48 in\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNet \/ Gross Weight\u003c\/td\u003e\n\u003ctd\u003e208.78 \/ 239.86 lb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAmbient Temperature\u003c\/td\u003e\n\u003ctd\u003eCooling: -13–122°F • Heating: -13–75°F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAdditional Charge\u003c\/td\u003e\n\u003ctd\u003e0.32 oz\/ft (3\/8\" liquid line)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"hvx-desc-card\"\u003e\n\u003ch3 class=\"hvx-section-title\"\u003eDocuments \u0026amp; Downloads\u003c\/h3\u003e\n\u003cul style=\"margin: 0; padding-left: 18px;\" class=\"hvx-muted\"\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/media.cooperandhunter.us\/4691\/CH-R48LCU-230VO_CH-RH48LCCT.pdf\" class=\"hvx-link\"\u003eSubmittal Sheet: CH-R48LCU-230VO + CH-RH48LCCT\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/media.cooperandhunter.us\/4695\/CH-RHP48LCU-230VO_CH-RH48LCCT.pdf\" class=\"hvx-link\"\u003eSubmittal Sheet: CH-RHP48LCU-230VO + CH-RH48LCCT\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/media.cooperandhunter.us\/4214\/CH-R48LCU-230VO-%2B-CH-RS48LCDT-HS.pdf\" class=\"hvx-link\"\u003eSubmittal Sheet: CH-R48LCU-230VO + CH-RS48LCDT-HS\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/media.cooperandhunter.us\/4621\/CH-R48LCU-230VO-%2B-CH-RS48LCAHU.pdf\" class=\"hvx-link\"\u003eSubmittal Sheet: CH-R48LCU-230VO + CH-RS48LCAHU\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/media.cooperandhunter.us\/4628\/CH-R48LCU-230VO_CH-RSH48LCFC.pdf\" class=\"hvx-link\"\u003eSubmittal Sheet: CH-R48LCU-230VO + CH-RSH48LCFC\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/media.cooperandhunter.us\/4692\/CH-R48LCU-230VO_CH-RSH48LCCT.pdf\" class=\"hvx-link\"\u003eSubmittal Sheet: CH-R48LCU-230VO + CH-RSH48LCCT\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/media.cooperandhunter.us\/4200\/SlimDuct-Leaflet-R454B.pdf\" class=\"hvx-link\"\u003eSlimDuct Leaflet (R454B)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/media.cooperandhunter.us\/4654\/Installation-manual-R454B-Ceiling-cassette_compressed.pdf\" class=\"hvx-link\"\u003eCeiling Cassette Installation Manual (R454B)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/media.cooperandhunter.us\/4655\/Owners_-manual-R454B-Ceiling-cassette_compressed.pdf\" class=\"hvx-link\"\u003eCeiling Cassette Owner’s Manual (R454B)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/media.cooperandhunter.us\/3309\/120N--uses-and-installation-manual.pdf\" class=\"hvx-link\"\u003e120N Wire Controller — Uses \u0026amp; Installation Manual\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/media.cooperandhunter.us\/3198\/MultiZone-Combination-HYPER.pdf\" class=\"hvx-link\"\u003eMultiZone Combination Guide — Hyper\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/media.cooperandhunter.us\/3199\/MultiZone-Combination-Regular.pdf\" class=\"hvx-link\"\u003eMultiZone Combination Guide — Regular\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"hvx-desc-card\"\u003e\n\u003ch3 class=\"hvx-section-title\"\u003eImportant\u003c\/h3\u003e\n\u003cul style=\"margin: 0; padding-left: 18px;\" class=\"hvx-muted\"\u003e\n\u003cli\u003eProfessional installation is recommended.\u003c\/li\u003e\n\u003cli\u003eMatch line set sizes to the equipment: 3\/8\" liquid and 3\/4\" suction.\u003c\/li\u003e\n\u003cli\u003eVerify the dedicated circuit is sized per equipment MCA and local code.\u003c\/li\u003e\n\u003cli\u003eNeed help choosing equipment? \u003ca href=\"https:\/\/hvacsupplies.com\/pages\/contact\" class=\"hvx-link\"\u003ehvacsupplies.com\/pages\/contact\u003c\/a\u003e • \u003ca href=\"tel:+18005438933\" class=\"hvx-link\"\u003e(800) 543-8933\u003c\/a\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"hvx-desc-card hvx-faq\"\u003e\n\u003ch3 class=\"hvx-section-title\"\u003eFAQs\u003c\/h3\u003e\n\u003cdetails\u003e\n\u003csummary\u003eDoes the cassette include a condensate pump?\u003c\/summary\u003e\n\u003cp class=\"hvx-muted\"\u003eYes. CH-RH48LCCT includes a built-in pump with float switch (20.9\" lift).\u003c\/p\u003e\n\u003c\/details\u003e\n\u003cdetails\u003e\n\u003csummary\u003eWhat line set sizes are required?\u003c\/summary\u003e\n\u003cp class=\"hvx-muted\"\u003e3\/8\" liquid line and 3\/4\" suction (gas) line.\u003c\/p\u003e\n\u003c\/details\u003e\n\u003cdetails\u003e\n\u003csummary\u003eHow cold can the outdoor unit operate in heating?\u003c\/summary\u003e\n\u003cp class=\"hvx-muted\"\u003eCH-R48LCU-230VO supports heating operation down to -13°F ambient.\u003c\/p\u003e\n\u003c\/details\u003e\n\u003cdetails\u003e\n\u003csummary\u003eCan I control the system with an app?\u003c\/summary\u003e\n\u003cp class=\"hvx-muted\"\u003eSmart Kit capability supports app control through the C\u0026amp;H platform after setup.\u003c\/p\u003e\n\u003c\/details\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e","brand":"Cooper\u0026Hunter","offers":[{"title":"No Installation","offer_id":42691127541803,"sku":"CH-RH48LCCT + CH-R48LCU-230VO","price":4061.0,"currency_code":"USD","in_stock":true},{"title":"25FT","offer_id":42691127574571,"sku":"CH-RH48LCCT + CH-R48LCU-230VO","price":4542.0,"currency_code":"USD","in_stock":true},{"title":"50FT","offer_id":42691127607339,"sku":"CH-RH48LCCT + CH-R48LCU-230VO","price":4735.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0625\/5647\/1339\/files\/2-ZoneDuctlessMiniSplitAC_HeatPump48000BTU_24.png?v=1769198479"}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0625\/5647\/1339\/collections\/brand1.jpg?v=1770677688","url":"https:\/\/hvacsupplies.com\/collections\/cooper-and-hunter.oembed?page=13","provider":"HVACSupplies.com","version":"1.0","type":"link"}